RECTRON SPA2003-T-S-A01

SPA2003
-T-S-A01
SILICON RECTIFIER
VOLAGE 200 Volts CURRENT 20 Ampere
FEATURES
* Low cost
* Low leakage
* Low forward voltage drop
* High current capability
* High surge current capability
* Ideal for solar panel PV application such as By-Pass diode
R-7
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 2.08 grams
.065 (1.65)
.96 (24.5)
MIN.
.061 (1.55)
DIA.
.299 (7.6)
.291 (7.4)
.319 (8.1)
.311 (7.9)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
DIA.
.96 (24.5)
MIN.
resistive or inductive load.
Dimensions in inches and (millimeters)
o
MA X IMUM R AT ING S (At T A = 25 C unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum DC Forward Current @T L=125 oC(Note 2)
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squared Time
SYMBOL
VRRM
SPA2003-T-S-A01
VRMS
140
Volts
VDC
200
Volts
IO
20
Amps
I FSM
400
Amps
I T
663.7
A 2S
2
Typical Junction Capacitance (Note)
Typical Thermal Resistance
Operating Temperature Range
Storage Temperature Range
200
CJ
125
R θJC
2.6
R θJL
1.2
UNITS
Volts
pF
0
C/ W
TJ
175(Tj<200oC in Bypass Mode)
T STG
-55 to +175
SYMBOL
VF
SPA2003-T-S-A01
1.0
10
100
UNITS
Volts
50
uAmps
0
C
0
C
o
ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 20A DC
@T A = 25 o C
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 100 o C
Maximum Full Load Reverse Current Average Full Cycle
.375” (9.5mm) lead length at T L = 75 oC
IR
NOTES : 1. Measured at 1 MH Z and applied reverse voltage of 4.0 volts
2. Heat-sink mounted 10mm max from body
3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
uAmps
2011-10
REV:O
AVERAGE FORWARD CURRENT, (A)
25
20
D.C with heat sink
15
10
5
0
50
Single Phase Half Wave
60Hz Inductive or
Resistive Load
100
150
175
200
INSTANTANEOUS REVERSE CURRENT, (uA)
RATING AND CHARACTERISTIC CURVES ( SPA2003-T-S-A01 )
1000
TA = 100 OC
100
TA = 25 OC
10
1.0
.1
0
O
LEAD TEMPERATURE, ( C)
20
50
10
1.0
TJ = 25 OC
Pulse width=300µS
1% Duty Cycle
0.2
0.4
0.6
0.8
1.0
1.2
1.4
60
80
100
120
140
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
1.6
1.8
2.0
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
0.1
40
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
600
8.3mS Single Half Sine-Wave
JEDEC Method
500
400
300
200
100
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Marking Description
Cathode Band
Rectron Logo
Part No.
V
2
Y M
0 A X
Year – code:
(Y:Last digit of year &
A:2010, B:2011…)
Month – code:
(M:0~9,O,N,D)
Voltage-code
01-------50V
02-------100V
03-------200V
04-------400V
05------600V
06------800V
07------1000V
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.