GECA40 40 Watt Series Commercial Wide-Range Input 2 Year Warranty • Wide-Range AC Input 90-264 VAC • Industry Standard Footprint - 3”x 5”x 1.25” • Conducted EMI Exceeds FCC Class B and CISPR 22 Class B • Single and Multiple Outputs • Approved to UL60950-1: 2003, CSA-22.2 No. 60950-1-03, IEC and EN60950-1 • CB Report Available • RoHS Compliant • Marked to LVD Specifications AC Input Universal Input 90-264 VAC, 47-63 Hz single phase. Input Current Maximum input current at 120 VAC, 60 Hz with full rated output load: Multiple models 1.7 A, Single models 1.0 A. Hold-Up Time 10 ms minimum with 40 W load, nominal line (120 VAC). Output Power 40 W continuous, 45 W peak. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on V1 and V2, foldback type on V3. Overvoltage Protection On V1 is 120% to 160%. See chart. Efficiency 75 to 80% at full rated load, nominal input voltage, depending on model and load distribution. Turn-on Time Less than 2 seconds. Input Protection Internal AC fuse provided. Designed to blow only if a catastrophic failure occurs in the unit. Fuse does not blow on overload or short circuit. Inrush Current Inrush is limited by internal thermistors. Inrush at 240 VAC under cold start conditions will not exceed 37A. Temperature Coefficient 0.03%/°C typical on all outputs. Temperature Range Designed for 0 to 45°C operation at full rated output power; derate output current and total output power by 2.5% per °C above 45°C. Unless otherwise noted, all parameters are nominal values measured at 120 VAC @25˚C and 0-95% relative humidity, non-condensing. For limits at unusual operatiing conditions, consult factory. Output Noise 0.5% rms, 1% pk-pk typical (see chart), 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply with load terminated with 0.1 μF capacitor. Transient Response Main output—500 μs typical response time for return to within 0.5% of final value for a 50% load step change. ∆i/ ∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/ shutdown overshoot less than 3%. Switching Frequency 70 kHz +/-10 kHz. Voltage Adjustment Provided on V1. Adjustable voltages are preset at factory. Outputs are capable of minimum +/- 5% change from nominal setting. Multiple output models - V2 voltage will track V1 adjustment. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility EN55022 Class B; FCC Class B EN61000-4-2, Level 3 EN61000-4-3, Level 3 EN61000-4-4, Level 3 EN61000-4-5, Level 3 Safety Approvals SL Power Electronics, Corp. declares under our sole responsibility that all GECA models are in conformity with the applicable requirements of EN60950 following the provisions of the Low Voltage Directive 73/23/EEC. All GECA models are approved to UL60950-1: 2003, CSA-22.2 No. 60950-1-03, IEC and EN60950-1 MTBF 120kHrs. SL Power Electronics, Corp. • 6050 King Drive • Ventura CA, 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com GECA40 40 Watt Series Commercial Wide-Range Input Commercial Model Output No. Output (V) Current Minimum Current Maximum Line Regulation GECA40AG V1 +5 V 0.35 A 3.5 A +/-0.5% V2 +12 V 0 A 2 A +/-1% V3 -12 V 0 A 0.3 A +/-1% GECA40BG V1 +5 V 0.35 A 3.5 A +/-0.5% Load Regulation V1 OVP Set Point +/-3% Ripple & Noise(P-P) 6.6 +/-0.9 V 50 mV +/-10% 120 mV +/-5% 120 mV +/-3% 6.6 +/-0.9 V 50 mV V2 +12V 0 A 2 A +/-1% +/-10% 120 mV V3 -5 V 0 A 0.3 A +/-1% +/-5% 50 mV GECA40HG V1 +3.3 V 0.4 A 4 A +/-0.5% V2 +12 V 0 A 2 A +/-1% +/-3% 4.4 +/-0.6 V 50 mV +/-10% 120 mV +/-5% 120 mV V3 -12 V 0 A 0.3 A +/-1% GECA40DG V1 +5 V 0.35 A 3.5 A +/-0.5% V2 +24 V 0 A 1.2 A V3 -12 V 0 A 0.3 A GECA40-5G V1 5 V 0 A 7 A +/-0.5% +/-3% 7.0 +/-1.0 V 50 mV GECA40-12G V1 12 V 0 A 3.3 A +/-0.5% +/-3% 16.8 +/-2.4 V 120 mV +/-3% 6.6 +/-0.9 V 50 mV +/-1% +/-10% 240 mV +/-1% +/-5% 120 mV GECA40-15G V1 15 V 0 A 2.7 A +/-0.5% +/-3% 21.0 +/-3.0 V 150 mV GECA40-24G V1 24 V 0 A 1.7 A +/-0.5% +/-3% 33.6 +/-4.8 V 240 mV Environmental Specifications ENVIRONMENT OPERATING NON-OPERATING Temperature (A) Humidity (A) Shock (B) Altitude Vibration (C) 0 to 45°C 20 to 90% RH 20 gpk -500 to 10,000 ft 1.5 grms’ 0.0032 g2/Hz -40 to +85°C 10 to 95% RH 40 gpk -500 to 40,000 ft 5 grms’ 0.026 g2/Hz A.Units should be allowed to warm up/operate under non-condensing conditions before application of power. B.Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. C.Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. GECA40 Series Mechanical Specifications CON 1: MOLEX P/N 26-60-4030, w/center PIN Removed 0.156 [3.96 mm] CTR Header CON 2: MOLEX P/N 26-60-4060, 0.156 [3.96 mm] CTR Header Input J1 PIN 1) PIN 3) AC Line AC Neutral Output J2 Multiple Output Models Single Output Models PIN 1) PIN 2) PIN 3) PIN 4) PIN 5) PIN 6) Output 2 Common Common Output 1 Output 1 Output 3 Output 1 Output 1 Output 1 Common Common Common Mating Connector MOLEX Housing P/N Contacts P/N Input 09-50-3031 08-52-0072 Output 09-50-3061 08-52-0072 Note: 5A maximum recommended current per Connector PIN Weight 1.0 lbs Max [0.45 kg Max.] Tolerance X.XX=0.030 X.XXX=0.010 [0.mm] SL Power Electronics, Corp. • 6050 King Drive • Ventura CA, 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:[email protected] • www.slpower.com Data Sheet © 2006 SL Power Electronics, Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. Rev.8/30/06