NSC LM1882

LM1882 • 54ACT715
LM1882-R • 54ACT715-R Programmable Video Sync
Generator
General Description
The ’ACT715/LM1882 and ’ACT715-R/LM1882-R are 20-pin
TTL-input compatible devices capable of generating Horizontal, Vertical and Composite Sync and Blank signals for
televisions and monitors. All pulse widths are completely definable by the user. The devices are capable of generating
signals for both interlaced and noninterlaced modes of operation. Equalization and serration pulses can be introduced
into the Composite Sync signal when needed.
Four additional signals can also be made available when
Composite Sync or Blank are used. These signals can be
used to generate horizontal or vertical gating pulses, cursor
position or vertical Interrupt signal.
These devices make no assumptions concerning the system
architecture. Line rate and field/frame rate are all a function
of the values programmed into the data registers, the status
register, and the input clock frequency.
The ’ACT715/LM1882 is mask programmed to default to a
Clock Disable state. Bit 10 of the Status Register, Register 0,
defaults to a logic “0”. This facilitates (re)programming before operation.
The ’ACT715-R/LM1882-R is the same as the ’ACT715/
LM1882 in all respects except that the ’ACT715-R/
LM1882-R is mask programmed to default to a Clock Enabled state. Bit 10 of the Status Register defaults to a logic
“1”. Although completely (re)programmable, the ’ACT715-R/
LM1882-R version is better suited for applications using the
default 14.31818 MHz RS-170 register values. This feature
allows power-up directly into operation, following a single
CLEAR pulse.
Features
n Maximum Input Clock Frequency > 130 MHz
n Interlaced and non-interlaced formats available
n Separate or composite horizontal and vertical Sync and
Blank signals available
n Complete control of pulse width via register
programming
n All inputs are TTL compatible
n 8 mA drive on all outputs
n Default RS170/NTSC values mask programmed into
registers
n 4 KV minimum ESD immunity
n ’ACT715-R/LM1882-R is mask programmed to default to
a Clock Enable state for easier start-up into
14.31818 MHz RS170 timing
Connection Diagrams
Pin Assignment for
DIP and SOIC
Pin Assignment
for LCC
DS100232-1
Order Number LM1882CN or LM1882CM
For Default RS-170, Order Number
LM1882-RCN or LM1882-RCM
DS100232-2
TRI-STATE ® is a registered trademark of National Semiconductor Corporation.
FACT™ is a trademark of Fairchild Semiconductor Corporation.
© 1998 National Semiconductor Corporation
DS100232
www.national.com
LM1882 • 54ACT715 • LM1882-R • 54ACT715-R Programmable Video Sync Generator
December 1998
Logic Block Diagram
DS100232-3
Pin Description
There are a Total of 13 inputs and 5 outputs on the ’ACT715/
LM1882.
Data Inputs D0–D7: The Data Input pins connect to the Address Register and the Data Input Register.
ADDR/DATA: The ADDR/DATA signal is latched into the device on the falling edge of the LOAD signal. The signal determines if an address (0) or data (1) is present on the data bus.
L/HBYTE: The L/HBYTE signal is latched into the device on
the falling edge of the LOAD signal. The signal determines if
data will be read into the 8 LSB’s (0) or the 4 MSB’s (1) of the
Data Registers. A 1 on this pin when an ADDR/DATA is a 0
enables Auto-Load Mode.
LOAD: The LOAD control pin loads data into the Address or
Data Registers on the rising edge. ADDR/DATA and
L/HBYTE data is loaded into the device on the falling edge of
the LOAD. The LOAD pin has been implemented as a
Schmitt trigger input for better noise immunity.
ODD/EVEN: Output that identifies if display is in odd (HIGH)
or even (LOW) field of interlace when device is in interlaced
mode of operation. In noninterlaced mode of operation this
output is always HIGH. Data can be serially scanned out on
this pin during Scan Mode.
VCSYNC: Outputs Vertical or Composite Sync signal based
on value of the Status Register. Equalization and Serration
pulses will (if enabled) be output on the VCSYNC signal in
composite mode only.
VCBLANK: Outputs Vertical or Composite Blanking signal
based on value of the Status Register.
HBLHDR: Outputs Horizontal Blanking signal, Horizontal
Gating signal or Cursor Position based on value of the Status Register.
HSYNVDR: Outputs Horizontal Sync signal, Vertical Gating
signal or Vertical Interrupt signal based on value of Status
Register.
CLOCK: System CLOCK input from which all timing is derived. The clock pin has been implemented as a Schmitt trigger for better noise immunity. The CLOCK and the LOAD
signal are asynchronous and independent. Output state
changes occur on the falling edge of CLOCK.
CLR: The CLEAR pin is an asynchronous input that initializes the device when it is HIGH. Initialization consists of setting all registers to their mask programmed values, and initializing all counters, comparators and registers. The CLEAR
pin has been implemented as a Schmitt trigger for better
noise immunity. A CLEAR pulse should be asserted by the
user immediately after power-up to ensure proper initialization of the registers — even if the user plans to (re)program
the device.
Register Description
All of the data registers are 12 bits wide. Width’s of all pulses
are defined by specifying the start count and end count of all
pulses. Horizontal pulses are specified with-respect-to the
number of clock pulses per line and vertical pulses are specified with-respect-to the number of lines per frame.
REG0 — STATUS REGISTER
The Status Register controls the mode of operation, the signals that are output and the polarity of these outputs. The default value for the Status Register is 0 (000 Hex) for the
’ACT715/LM1882 and is “1024” (400 Hex) for the
’ACT715-R/LM1882-R.
Note: A CLEAR pulse will disable the CLOCK on the ’ACT715/LM1882 and
will enable the CLOCK on the ’ACT715-R/LM1882-R.
www.national.com
2
Register Description
HORIZONTAL INTERVAL REGISTERS
(Continued)
The Horizontal Interval Registers determine the number of
clock cycles per line and the characteristics of the Horizontal
Sync and Blank pulses.
REG1 — Horizontal Front Porch
Bits 0–2
B2
B1
B0
VCBLANK
VCSYNC
0
0
0
CBLANK
CSYNC
HBLHDR HSYNVDR
HGATE
VGATE
REG2 —
REG3 —
REG4 —
(DEFAULT)
0
0
1
VBLANK
CSYNC
HBLANK
VGATE
0
1
0
CBLANK
VSYNC
HGATE
HSYNC
0
1
1
VBLANK
VSYNC
HBLANK
HSYNC
1
0
0
CBLANK
CSYNC
CURSOR
VINT
1
0
1
VBLANK
CSYNC
HBLANK
VINT
1
1
0
CBLANK
VSYNC
CURSOR
HSYNC
1
1
1
VBLANK
VSYNC
HBLANK
HSYNC
VERTICAL INTERVAL REGISTERS
The Vertical Interval Registers determine the number of lines
per frame, and the characteristics of the Vertical Blank and
Sync Pulses.
REG5 — Vertical Front Porch
REG6 — Vertical Sync Pulse End Time
REG7 — Vertical Blanking Width
# of Lines per Frame
REG8 — Vertical Interval Width
Bits 3–4
B4
B3
0
0
(DEFAULT)
Mode of Operation
Interlaced Double Serration and
EQUALIZATION AND SERRATION PULSE
SPECIFICATION REGISTERS
These registers determine the width of equalization and serration pulses and the vertical interval over which they occur.
REG 9 — Equalization Pulse Width End Time
REG10 — Serration Pulse Width End Time
REG11 — Equalization/Serration Pulse Vertical
Interval Start Time
REG12 — Equalization/Serration Pulse Vertical
Interval End Time
Equalization
0
1
Non Interlaced Double Serration
1
0
Illegal State
1
1
Non Interlaced Single Serration and
Equalization
Double Equalization and Serration mode will output equalization and serration pulses at twice the HSYNC frequency
(i.e., 2 equalization or serration pulses for every HSYNC
pulse). Single Equalization and Serration mode will output
an equalization or serration pulse for every HSYNC pulse. In
Interlaced mode equalization and serration pulses will be
output during the VBLANK period of every odd and even
field. Interlaced Single Equalization and Serration mode is
not possible with this part.
VERTICAL INTERRUPT SPECIFICATION REGISTERS
These Registers determine the width of the Vertical Interrupt
signal if used.
REG13 — Vertical Interrupt Activate Time
REG14 — Vertical Interrupt Deactivate Time
Bits 5–8
Bits 5 through 8 control the polarity of the outputs. A value of
zero in these bit locations indicates an output pulse active
LOW. A value of 1 indicates an active HIGH pulse.
B5 — VCBLANK Polarity
B6 — VCSYNC Polarity
B7 — HBLHDR Polarity
B8 — HSYNVDR Polarity
CURSOR LOCATION REGISTERS
These 4 registers determine the cursor position location, or
they generate separate Horizontal and Vertical Gating signals.
REG15 — Horizontal Cursor Position Start Time
REG16 — Horizontal Cursor Position End Time
REG17 — Vertical Cursor Position Start Time
REG18 — Vertical Cursor Position End Time
Bits 9–11
Bits 9 through 11 enable several different features of the device.
B9 —
Enable Equalization/Serration Pulses (0)
Disable Equalization/Serration Pulses (1)
B10 — Disable System Clock (0)
B11 —
Horizontal Sync Pulse End Time
Horizontal Blanking Width
# of Clocks per
Horizontal Interval Width
Line
Signal Specification
HORIZONTAL SYNC AND BLANK
SPECIFICATIONS
All horizontal signals are defined by a start and end time.
The start and end times are specified in number of clock
cycles per line. The start of the horizontal line is considered
pulse 1 not 0. All values of the horizontal timing registers are
referenced to the falling edge of the Horizontal Blank signal
(see Figure 1). Since the first CLOCK edge, CLOCK #1,
causes the first falling edge of the Horizontal Blank reference
pulse, edges referenced to this first Horizontal edge are n +
1 CLOCKs away, where “n” is the width of the timing in question. Registers 1, 2, and 3 are programmed in this manner.
The horizontal counters start at 1 and count until HMAX. The
value of HMAX must be divisible by 2. This limitation is im-
Enable System Clock (1)
Default values for B10 are “0” in the ’ACT715/
LM1882 and “1” in the ’ACT715-R/LM1882-R.
Disable Counter Test Mode (0)
Enable Counter Test Mode (1)
This bit is not intended for the user but is for internal
testing only.
3
www.national.com
Signal Specification
ization pulses at 2 x the horizontal frequency. Horizontal
signals will change on the falling edge of the CLOCK signal.
Signal specifications are shown below.
(Continued)
posed because during interlace operation this value is internally divided by 2 in order to generate serration and equal-
DS100232-4
FIGURE 1. Horizontal Waveform Specification
Horizontal
Horizontal
Horizontal
Horizontal
Period (HPER) =
Blanking Width: =
Sync Width: =
Front Porch: =
Vertical Syncing Width = [REG(6) − REG(5)] x hper/n
Vertical Front Porch = [REG(5) − 1] x hper/n
where n = 1 for noninterlaced
n = 2 for interlaced
REG(4) x ckper
[REG(3) − 1] x ckper
[REG(2) − REG(1)] x ckper
[REG(1) − 1] x ckper
COMPOSITE SYNC AND BLANK SPECIFICATION
Composite Sync and Blank signals are created by logically
ANDing (ORing) the active LOW (HIGH) signals of the corresponding vertical and horizontal components of these signals. The Composite Sync signal may also include serration
and/or equalization pulses. The Serration pulse interval occurs in place of the Vertical Sync interval. Equalization
pulses occur preceding and/or following the Serration
pulses. The width and location of these pulses can be programmed through the registers shown below. (See Figure 3.)
Horizontal Equalization PW = [REG(9) − REG(1)] x ckper
VERTICAL SYNC AND BLANK SPECIFICATION
All vertical signals are defined in terms of number of lines per
frame. This is true in both interlaced and noninterlaced
modes of operation. Care must be taken to not specify the
Vertical Registers in terms of lines per field. Since the first
CLOCK edge, CLOCK #1, causes the first falling edge of the
Vertical Blank (first Horizontal Blank) reference pulse, edges
referenced to this first edge are n + 1 lines away, where “n”
is the width of the timing in question. Registers 5, 6, and 7
are programmed in this manner. Also, in the interlaced
mode, vertical timing is based on half-lines. Therefore registers 5, 6, and 7 must contain a value twice the total horizontal
(odd and even) plus 1 (as described above). In
non-interlaced mode, all vertical timing is based on
whole-lines. Register 8 is always based on whole-lines and
does not add 1 for the first clock. The vertical counter starts
at the value of 1 and counts until the value of VMAX. No restrictions exist on the values placed in the vertical registers.
Vertical Blank will change on the leading edge of HBLANK.
Vertical Sync will change on the leading edge of HSYNC.
(See Figure 2.)
Vertical Frame Period (VPER) = REG(8) x hper
Vertical Field Period (VPER/n) = REG(8) x hper/n
Vertical Blanking Width = [REG(7) − 1] x hper/n
www.national.com
REG 9 = (HFP) + (HEQP) + 1
Horizontal Serration PW:
Where
4
=
[REG(4)/n + REG(1) −
REG(10)] x ckper
REG 10 = (HFP) +
(HPER/2) − (HSERR) + 1
noninterlaced single serration/
n = 1 for
equalization
n = 2 for noninterlaced
equalization
n = 2 for interlaced operation
double
serration/
Signal Specification
(Continued)
DS100232-5
FIGURE 2. Vertical Waveform Specification
DS100232-12
FIGURE 3. Equalization/Serration Interval Programming
HORIZONTAL AND VERTICAL GATING SIGNALS
Horizontal Drive and Vertical Drive outputs can be utilized as
general purpose Gating Signals. Horizontal and Vertical Gating Signals are available for use when Composite Sync and
Blank signals are selected and the value of Bit 2 of the Status Register is 0. The Vertical Gating signal will change in the
same manner as that specified for the Vertical Blank.
Horizontal Gating Signal Width = [REG(16) − REG(15)] x
ckper
Vertical Gating Signal Width: = [REG(18) − REG(17)] x
hper
Addressing Logic
The register addressing logic is composed of two blocks of
logic. The first is the address register and counter (ADDRCNTR), and the second is the address decode (ADDRDEC).
ADDRCNTR LOGIC
Addresses for the data registers can be generated by one of
two methods. Manual addressing requires that each byte of
each register that needs to be loaded needs to be addressed. To load both bytes of all 19 registers would require
a total of 57 load cycles (19 address and 38 data cycles).
Auto Addressing requires that only the initial register value
be specified. The Auto Load sequence would require only 39
load cycles to completely program all registers (1 address
and 38 data cycles). In the auto load sequence the low order
byte of the data register will be written first followed by the
high order byte on the next load cycle. At the time the High
Byte is written the address counter is incremented by 1. The
counter has been implemented to loop on the initial value
loaded into the address register. For example: If a value of 0
was written into the address register then the counter would
count from 0 to 18 before resetting back to 0. If a value of 15
was written into the address register then the counter would
count from 15 to 18 before looping back to 15. If a value
greater than or equal to 18 is placed into the address register
the counter will continuously loop on this value. Auto addressing is initiated on the falling edge of LOAD when ADDRDATA is 0 and LHBYTE is 1. Incrementing and loading of
data registers will not commence until the falling edge of
LOAD after ADDRDATA goes to 1. The next rising edge of
CURSOR POSITION AND VERTICAL INTERRUPT
The Cursor Position and Vertical Interrupt signal are available when Composite Sync and Blank signals are selected
and Bit 2 of the Status Register is set to the value of 1. The
Cursor Position generates a single pulse of n clocks wide
during every line that the cursor is specified. The signals are
generated by logically ORing (ANDing) the active LOW
(HIGH) signals specified by the registers used for generating
Horizontal and Vertical Gating signals. The Vertical Interrupt
signal generates a pulse during the vertical interval specified. The Vertical Interrupt signal will change in the same
manner as that specified for the Vertical Blanking signal.
Horizontal Cursor Width = [REG(16) − REG(15)] x ckper
Vertical Cursor Width = [REG(18) − REG(17)] x hper
Vertical Interrupt Width = [REG(14) − REG(13)] x hper
5
www.national.com
Addressing Logic
(Continued)
LOAD will load the first byte of data. Auto Incrementing is
disabled on the falling edge of LOAD after ADDRDATA and
LHBYTE goes low.
Manual Addressing Mode
Cycle #
Load Falling Edge
Load Rising Edge
1
Enable Manual Addressing
Load Address m
2
Enable Lbyte Data Load
Load Lbyte m
3
Enable Hbyte Data Load
Load Hbyte m
4
Enable Manual Addressing
Load Address n
5
Enable Lbyte Data Load
Load Lbyte n
6
Enable Hbyte Data Load
Load Hbyte n
DS100232-7
Auto Addressing Mode
Cycle #
Load Falling Edge
Load Rising Edge
1
Enable Auto Addressing
Load Start Address n
2
Enable Lbyte Data Load
Load Lbyte (n)
3
Enable Hbyte Data Load
Load Hbyte (n); Inc Counter
4
Enable Lbyte Data Load
Load Lbyte (n+1)
5
Enable Hbyte Data Load
Load Hbyte (n+1); Inc Counter
6
Enable Manual Addressing
Load Address
DS100232-8
CLOCK is disabled. Clocking the part during a Vectored Restart or Vectored Clear state will have no effect on the part.
To resume operation in the new state, or disable the Vectored Restart or Vectored Clear state, another
non-ADDRDEC address must be loaded. Operation will begin in the new state on the rising edge of the non-ADDRDEC
load pulse. It is recommended that an unused address be
loaded following an ADDRDEC operation to prevent data
registers from accidentally being corrupted. The following
Addresses are used by the device.
ADDRDEC LOGIC
The ADDRDEC logic decodes the current address and generates the enable signal for the appropriate register. The enable values for the registers and counters change on the falling edge of LOAD. Two types of ADDRDEC logic is enabled
by 2 pair of addresses, Addresses 22 or 54 (Vectored Restart logic) and Addresses 23 or 55 (Vectored Clear logic).
Loading these addresses will enable the appropriate logic
and put the part into either a Restart (all counter registers are
reinitialized with preprogrammed data) or Clear (all registers
are cleared to zero) state. Reloading the same ADDRDEC
address will not cause any change in the state of the part.
The outputs during these states are frozen and the internal
www.national.com
Address 0
Status Register REG0
Address 1–18Data Registers REG1–REG18
6
Addressing Logic
is possible without interruption or data and performance corruption. If the defaulted 14.31818 MHz RS-170 values are
being used, preconditioning and restarting can be minimized
by using the CLEAR pulse instead of the Vectored Restart
operation. The ’ACT715-R/LM1882-R is better suited for this
application because it eliminates the need to program a 1
into Bit 10 of the Status Register to enable the CLOCK. Gen
Locking to another count location other than the very beginning or separate horizontal/vertical resetting is not possible
with the ’ACT715/LM1882 nor the ’ACT715-R/LM1882-R.
(Continued)
Address 19–21Unused
Address 22/54Restart Vector (Restarts Device)
Address 23/55Clear Vector (Zeros All Registers)
Address 24–31Unused
Address 32–50Register Scan Addresses
Address 51–53Counter Scan Addresses
Address 56–63Unused
At any given time only one register at most is selected. It is
possible to have no registers selected.
SCAN MODE LOGIC
A scan mode is available in the ACT715/LM1882 that allows
the user to non-destructively verify the contents of the registers. Scan mode is invoked through reading a scan address
into the address register. The scan address of a given register is defined by the Data register address + 32. The internal
Clocking signal is disabled when a scan address is read.
Disabling the clock freezes the device in it’s present state.
Data can then be serially scanned out of the data registers
through the ODD/EVEN Pin. The LSB will be scanned out
first. Since each register is 12 bits wide, completely scanning
out data of the addressed register will require 12 CLOCK
pulses. More than 12 CLOCK pulses on the same register
will only cause the MSB to repeat on the output.
Re-scanning the same register will require that register to be
reloaded. The value of the two horizontal counters and 1 vertical counter can also be scanned out by using address numbers 51–53. Note that before the part will scan out the data,
the LOAD signal must be brought back HIGH.
Normal device operation can be resumed by loading in a
non-scan address. As the scanning of the registers is a
non-destructive scan, the device will resume correct operation from the point at which it was halted.
VECTORED RESTART ADDRESS
The function of addresses 22 (16H) or 54 (36H) are similar to
that of the CLR pin except that the preprogramming of the
registers is not affected. It is recommended but not required
that this address is read after the initial device configuration
load sequence. A 1 on the ADDRDATA pin (Auto Addressing
Mode) will not cause this address to automatically increment. The address will loop back onto itself regardless of the
state of ADDRDATA unless the address on the Data inputs
has been changed with ADDRDATA at 0.
VECTORED CLEAR ADDRESS
Addresses 23 (17H) or 55 (37H) is used to clear all registers
to zero simultaneously. This function may be desirable to use
prior to loading new data into the Data or Status Registers.
This address is read into the device in a similar fashion as all
of the other registers. A 1 on the ADDRDATA pin (Auto Addressing Mode) will not cause this address to automatically
increment. The address will loop back onto itself regardless
of the state of ADDRDATA unless the address on the Data
inputs has been changed with ADDRDATA at 0.
RS170 Default Register Values
The tables below show the values programmed for the
RS170 Format (using a 14.31818 MHz clock signal) and
how they compare against the actual EIA RS170 Specifications. The default signals that will be output are CSYNC,
CBLANK, HDRIVE and VDRIVE. The device initially starts at
the beginning of the odd field of interlace. All signals have
active low pulses and the clock is disabled at power up. Registers 13 and 14 are not involved in the actual signal information. If the Vertical Interrupt was selected so that a pulse indicating the active lines would be output.
DS100232-9
FIGURE 4. ADDRDEC Timing
GEN LOCKING
The ’ACT715/LM1882 and ’ACT715-R/LM1882-R is designed for master SYNC and BLANK signal generation.
However, the devices can be synchronized (slaved) to an external timing signal in a limited sense. Using Vectored Restart, the user can reset the counting sequence to a given location, the beginning, at a given time, the rising edge of the
LOAD that removes Vector Restart. At this time the next
CLOCK pulse will be CLOCK 1 and the count will restart at
the beginning of the first odd line.
Preconditioning the part during normal operation, before the
desired synchronizing pulse, is necesasry. However, since
LOAD and CLOCK are asynchronous and independent, this
7
www.national.com
RS170 Default Register Values
Reg
D Value H
(Continued)
Register Description
REG0
0
000
Status Register (715/LM1882)
REG0
1024
400
Status Register
(715-R/LM1882-R)
REG1
23
017
HFP End Time
REG2
91
05B
HSYNC Pulse End Time
REG3
157
09D
HBLANK Pulse End Time
REG4
910
38E
Total Horizontal Clocks
REG5
7
007
VFP End Time
REG6
13
00D
VSYNC Pulse End Time
REG7
41
029
VBLANK Pulse End Time
REG8
525
20D
Total Vertical Lines
REG9
57
039
Equalization Pulse End Time
REG10
410
19A
Serration Pulse Start Time
REG11
1
001
Pulse Interval Start Time
REG12
19
013
Pulse Interval End Time
REG13
41
029
Vertical Interrupt Activate Time
REG14
526
20E
Vertical Interrupt Deactivate Time
REG15
911
38F
Horizontal Drive Start Time
REG16
92
05C
Horizontal Drive End Time
REG17
1
001
Vertical Drive Start Time
REG18
21
015
Vertical Drive End Time
Rate
Input Clock
Period
14.31818 MHz
69.841 ns
Line Rate
15.73426 kHz
63.556 µs
Field Rate
59.94 Hz
16.683 ms
Frame Rate
29.97 Hz
33.367 ms
RS170 Horizontal Data
%H
Specification (µs)
4.749
7.47
4.7 ± 0.1
156 Clocks
10.895
17.15
10.9 ± 0.2
91 Clocks
6.356
10.00
0.1H ± 0.005H
Signal
Width
µs
HFP
22 Clocks
1.536
HSYNC Width
68 Clocks
HBLANK Width
HDRIVE Width
1.5 ± 0.1
HEQP Width
34 Clocks
2.375
3.74
2.3 ± 0.1
HSERR Width
68 Clocks
4.749
7.47
4.7 ± 0.1
HPER iod
910 Clocks
63.556
100
RS170 Vertical Data
VFP
3 Lines
190.67
6 EQP Pulses
VSYNC Width
3 Lines
190.67
6 Serration Pulses
VBLANK Width
20 Lines
1271.12
7.62
0.075V ± 0.005V
VDRIVE Width
11.0 Lines
699.12
4.20
0.04V ± 0.006V
VEQP Intrvl
9 Lines
VPERiod (field)
262.5 Lines
16.683 ms
16.683 ms/Field
VPERiod (frame)
525 Lines
33.367 ms
33.367 ms/Frame
www.national.com
3.63
8
9 Lines/Field
Absolute Maximum Ratings (Note 1)
Junction Temperature (TJ)
Ceramic
Plastic
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (VCC)
DC Input Diode Current (IIK)
VI = −0.5V
VI = VCC +0.5V
DC Input Voltage (VI)
DC Output Diode Current (IOK)
VO = −0.5V
VO = VCC +0.5V
DC Output Voltage (VO)
DC Output Source
or Sink Current (IO)
DC VCC or Ground Current
per Output Pin (ICC or IGND)
Storage Temperature (TSTG)
175˚C
140˚C
Recommended Operating
Conditions
−0.5V to +7.0V
−20 mA
+20 mA
−0.5V to VCC +0.5V
Supply Voltage (VCC)
Input Voltage (VI)
Output Voltage (VO)
Operating Temperature (TA)
54ACT
Minimum Input Edge Rate (∆V/∆t)
VIN from 0.8V to 2.0V
VCC @ 4.5V, 5.5V
−20 mA
+20 mA
−0.5V to VCC +0.5V
± 15 mA
4.5V to 5.5V
0V to VCC
0V to VCC
−55˚C to +125˚C
125 mV/ns
Note 1: Absolute maximum ratings are those values beyond which damage
to the device may occur. The databook specifications should be met, without
exception, to ensure that the system design is reliable over its power supply,
temperature and output/input loading variables. National does not recommend operation of FACT ® circuits outside databook specifications.
± 20 mA
−65˚C to +150˚C
DC Characteristics
For ’ACT Family Devices over Operating Temperature Range (unless otherwise specified)
VCC
Symbol
LM1882
TA = +25˚C
CL = 50 pF
to +85˚C
Units
Minimum High Level
4.5
4.49
4.4
4.4
4.4
V
Output Voltage
5.5
5.49
5.4
5.4
5.4
V
3.86
3.7
3.76
V
V
5.5
IOLD
to +125˚C
CL = 50 pF
(V)
4.5
VOL
LM1882
TA = −40˚C
Parameter
Typ
VOH
54ACT/LM1882
TA = −55˚C
Guaranteed Limits
4.86
4.7
4.76
Maximum Low Level
4.5
0.001
0.1
0.1
0.1
V
Output Voltage
5.5
0.001
0.1
0.1
0.1
V
4.5
0.36
0.5
0.44
V
5.5
0.36
Minimum Dynamic
Conditions
IOUT = −50 µA
(Note 2)
VIN = VIL/VIH
IOH = −8 mA
IOUT = 50 µA
0.5
0.44
V
5.5
32.0
32.0
mA
(Note 2)
VIN = VIL/VIH
IOH = +8 mA
VOLD = 1.65V
5.5
−32.0
−32.0
mA
VOHD = 3.85V
Output Current
IOHD
Minimum Dynamic
Output Current
IIN
Maximum Input
5.5
± 0.1
± 1.0
± 1.0
µA
VI = VCC, GND
5.5
8.0
160
80
µA
VIN = VCC, GND
1.6
1.5
mA
VIN = VCC − 2.1V
Leakage Current
ICC
Supply Current
Quiescent
ICCT
Maximum ICC/Input
5.5
0.6
Note 2: All outputs loaded; thresholds on input associated with input under test.
Note 3: Test Load 50 pF, 500Ω to Ground.
9
www.national.com
AC Electrical Characteristics
LM1882
TA = +25˚C
CL = 50 pF
VCC
Symbol
fMAXI
Parameter
(V)
LM1882
TA = −40˚C
to +125˚C
CL = 50 pF
to +85˚C
CL = 50 pF
Min
Max
Min
Units
Min
Typ
5.0
170
190
130
150
MHz
5.0
190
220
145
175
MHz
Clock to Any Output
5.0
4.0
13.0
15.5
3.5
19.5
3.5
18.5
ns
5.0
4.5
15.0
17.0
3.5
22.0
3.5
20.5
ns
5.0
4.0
11.5
16.0
3.0
20.0
3.0
19.5
ns
Interlaced fMAX
Max
54ACT/LM1882
TA = −55˚C
Max
(HMAX/2 is ODD)
fMAX
Non-Interlaced fMAX
(HMAX/2 is EVEN)
tPLH1
tPHL1
tPLH2
Clock to ODDEVEN
tPHL2
(Scan Mode)
tPLH3
Load to Outputs
AC Operating Requirements
Symbol
Parameter
VCC
LM1882
TA = +25˚C
(V)
Typ
54ACT/LM1882
TA = −55˚C
LM1882
TA = −40˚C
to +125˚C
to +85˚C
Units
Guaranteed Minimums
Control Setup Time
tsc
ADDR/DATA to LOAD−
tsc
L/HBYTE to LOAD−
5.0
3.0
4.0
4.5
4.5
ns
3.0
4.0
4.5
4.5
ns
5.0
2.0
4.0
4.5
4.5
ns
5.0
0
1.0
1.0
1.0
ns
0
1.0
1.0
1.0
ns
Data Setup Time
tsd
D7–D0 to LOAD+
Control Hold Time
thc
LOAD− to ADDR/DATA
LOAD− to L/HBYTE
Data Hold Time
thd
LOAD+ to D7–D0
5.0
1.0
2.0
2.0
2.0
ns
trec
LOAD+ to CLK (Note 4)
5.0
5.5
7.0
8.0
8.0
ns
Load Pulse Width
twld−
LOW
5.0
3.0
5.5
5.5
5.5
ns
twld+
HIGH
5.0
3.0
5.0
7.5
7.5
ns
twclr
CLR Pulse Width HIGH
5.0
5.5
6.5
9.5
9.5
ns
twck
CLOCK Pulse Width
5.0
2.5
3.0
4.0
3.5
ns
(HIGH or LOW)
Note 4: Removal of Vectored Reset or Restart to Clock.
Capacitance
Symbol
CIN
CPD
Parameter
Typ
Units
Input Capacitance
7.0
pF
Power Dissipation
17.0
pF
Capacitance
www.national.com
10
Conditions
VCC = 5.0V
VCC = 5.0V
Capacitance
(Continued)
DS100232-6
FIGURE 5. AC Specifications
Additional Applications Information
PREPROGRAMMING “ON-THE-FLY”
Although the ’ACT715/LM1882 and ’ACT715-R/LM1882-R
are completely programmable, certain limitations must be
set as to when and how the parts can be reprogrammed.
Care must be taken when reprogramming any End Time registers to a new value that is lower than the current value.
Should the reprogramming occur when the counters are at a
count after the new value but before the old value, then the
counters will continue to count up to 4096 before rolling over.
For this reason one of the following two precautions are recommended when reprogramming “on-the-fly”. The first recommendation is to reprogram horizontal values during the
horizontal blank interval only and/or vertical values during
the vertical blank interval only. Since this would require delicate timing requirements the second recommendation may
be more appropriate.
The second recommendation is to program a Vectored Restart as the final step of reprogramming. This will ensure that
all registers are set to the newly programmed values and
that all counters restart at the first CLK position. This will
avoid overrunning the counter end times and will maintain
the video integrity.
POWERING UP
The ’ACT715/LM1882 default value for Bit 10 of the Status
Register is 0. This means that when the CLEAR pulse is applied and the registers are initialized by loading the default
values the CLOCK is disabled. Before operation can begin,
Bit 10 must be changed to a 1 to enable CLOCK. If the default values are needed (no other programming is required)
then Figure 6 illustrates a hardwired solution to facilitate the
enabling of the CLOCK after power-up. Should control signals be difficult to obtain, Figure 7 illustrates a possible solution to automatically enable the CLOCK upon power-up. Use
of the ’ACT715-R/LM1882-R eliminates the need for most of
this circuitry. Modifications of the Figure 7 circuit can be
made to obtain the lone CLEAR pulse still needed upon
power-up.
Note that, although during a Vectored Restart none of the
preprogrammed registers are affected, some signals are affected for the duration of one frame only. These signals are
the Horizontal and Vertical Drive signals. After a Vectored
Restart the beginning of these signals will occur at the first
CLK. The end of the signals will occur as programmed. At
the completion of the first frame, the signals will resume to
their programmed start and end time.
11
www.national.com
Additional Applications Information
(Continued)
DS100232-10
FIGURE 6. Default RS170 Hardwire Configuration
DS100232-11
Note: A 74HC221A may be substituted for the 74HC423A Pin 6 and Pin 14 must be hardwired to GND
Components
R1: 4.7k
C1: 10 µF
R2:10k
C2: 50 pF
FIGURE 7. Circuit for Clear and Load Pulse Generation
www.national.com
12
13
Physical Dimensions
inches (millimeters) unless otherwise noted
20-Terminal Ceramic Leadless Chip Carrier (L)
NS Package Number E20A
20-Lead Ceramic Dual-In-Line Package (D)
NS Package Number J20A
www.national.com
14
Physical Dimensions
inches (millimeters) unless otherwise noted (Continued)
20-Lead Small Outline Integrated Circuit (S)
NS Package Number M20B
20-Lead Plastic Dual-In-Line Package (P)
NS Package Number N20B
15
www.national.com
LM1882 • 54ACT715 • LM1882-R • 54ACT715-R Programmable Video Sync Generator
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
2. A critical component in any component of a life support
1. Life support devices or systems are devices or sysdevice or system whose failure to perform can be reatems which, (a) are intended for surgical implant into
sonably expected to cause the failure of the life support
the body, or (b) support or sustain life, and whose faildevice or system, or to affect its safety or effectiveness.
ure to perform when properly used in accordance
with instructions for use provided in the labeling, can
be reasonably expected to result in a significant injury
to the user.
National Semiconductor
Corporation
Americas
Tel: 1-800-272-9959
Fax: 1-800-737-7018
Email: [email protected]
www.national.com
National Semiconductor
Europe
Fax: +49 (0) 1 80-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 1 80-530 85 85
English Tel: +49 (0) 1 80-532 78 32
Français Tel: +49 (0) 1 80-532 93 58
Italiano Tel: +49 (0) 1 80-534 16 80
National Semiconductor
Asia Pacific Customer
Response Group
Tel: 65-2544466
Fax: 65-2504466
Email: [email protected]
National Semiconductor
Japan Ltd.
Tel: 81-3-5639-7560
Fax: 81-3-5639-7507
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.