CUI CME-1538

date 06/2010
page 1 of 4
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
PART NUMBER: CME-1538-100LB
SPECIFICATIONS
parameter
conditions/description
directivity
omnidirectional
sensitivity
f= 1 KHz, 1Pa 0 dB= 1 V/Pa
min
nom
max
-41
-38
-35
dB
2
10
V dc
operating voltage
output impedance
f= 1 KHz, 1Pa
sensitivity reduction
f= 1 KHz, 1Pa Vs=2 V dc to 1.5 V dc
frequency
2.2
KΩ
-3
dBA
20
current consumption
Vs=2 V dc RL=2.2 KΩ
signal to noise ration
f= 1 KHz, 1 Pa A weighted
units
20,000
Hz
0.5
mA
58
dBA
operating temperature
-30
80
°C
storage temperature
-30
80
°C
0.1
g
dimenstions
ø4 x H1.5 mm
weight
material
brass (Au plating)
terminal
wire type
RoHS
yes
dustproof/waterproof level
IP67, IEC standard 529 edition 2.0 (1989)
APPEARANCE DRAWING
2.9 0.114
MAX
1.5 0.059
0.2
red (+)
black (-)
4.0 0.157
0.15
100.0 3.937
4.0 (2 PLCS)
1.0 0.039
0.5 (2 PLCS)
TOLERANCE:
±0.2mm UNLESS OTHERWISE
SPECIFIED
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2383 www.cui.com
date 06/2010
page 2 of 4
PART NUMBER: CME-1538-100LB
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
FREQUENCY RESPONSE CURVE
˃
ˀ˄˃
ˀ˅˃
ˀˆ˃
ˀˇ˃
ˀˈ˃
ˀˉ˃
ˀˊ˃
ˀˋ˃
˄˃˃
˄˃˃˃
˄˃˃˃˃
MEASUREMENT CIRCUIT
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2383 www.cui.com
˄˃˃˃˃˃
date 06/2010
page 3 of 4
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
PART NUMBER: CME-1538-100LB
MECHANICAL CHARACTERISTICS
item
test condition
evaluation standard
soldering heat resistance
Stripped wires are immersed in rosin for 5 seconds and then immersed in solder bath of 270 ±5°C for 3 ±0.5 seconds.
90% min. stripped wires should be wet
with solder (except edge of terminal).
PCB wire pull strength
The force of 4.9 N is applied for 30 sec. to double lead wire.
No damage or cutting off.
vibration test
The microphone should be measured after a vibration amplitude
of 1.5 mm with 10 ~ 55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
drop test
The microphone without packaging is subjected to 3 drops on
each axis from the height of 100 cm onto a 20 mm thick wooden
board.
The sensitivity should be within
±3dB compared with the initial
measurement.
ENVIRONMENT TEST
item
test condition
evaluation standard
high temperature test
After being placed in a chamber at +80°C for 1 hour.
low temperature test
After being placed in a chamber at -30°C for 1 hour.
humidity test
After being placed in a chamber at +40°C and 90 ±5% RH for
240 hours.
temperature cycle test
The part will be subjected to 10 cycles. One cycle will consist of:
+80к
+25к
+25к
-30к
1hr
0.5hr
1hr
0.5hr
1hr
0.5hr
The microphone will be measured
after being placed at +25°C for 6
hours. The value of the oscillation
frequency should be ±10% compared
to the initial measurements. The SPL
should be within ±3dB compared to
the initial measurements.
1hr
5.5 hrs
TEST CONDITIONS
standard test conditions
a) Temperature: +5 ~ +35°C
b) Humidity: 45 ~ 85%
c) Pressure: 860 ~ 1060 mbar
judgement test conditions
a) Temperature: +25 ±2°C
b) Humidity: 60 ~ 70%
c) Pressure: 860 ~ 1060 mbar
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2383 www.cui.com
date 06/2010
page 4 of 4
PART NUMBER: CME-1538-100LB
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
PACKAGING
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2383 www.cui.com