COVER DATA SHEET 1G bits DDR3 SDRAM EDJ1108DJBG (128M words × 8 bits) EDJ1116DJBG (64M words × 16 bits) Specifications Features • Density: 1G bits • Organization — 16M words × 8 bits × 8 banks (EDJ1108DJBG) — 8M words × 16 bits × 8 banks (EDJ1116DJBG) • Package — 78-ball FBGA (EDJ1108DJBG) — 96-ball FBGA (EDJ1116DJBG) — Lead-free (RoHS compliant) and Halogen-free • Power supply: VDD = 1.5V ± 0.075V • Data rate — 2133Mbps/1866Mbps/1600Mbps/1333Mbps (max) • 1KB page size (EDJ1108DJBG) — Row address: A0 to A13 — Column address: A0 to A9 • 2KB page size (EDJ1116DJBG) — Row address: A0 to A12 — Column address: A0 to A9 • Eight internal banks for concurrent operation • Interface: SSTL_15 • Burst length (BL): 8 and 4 with Burst Chop (BC) • Burst type (BT): — Sequential (8, 4 with BC) — Interleave (8, 4 with BC) • /CAS Latency (CL): 5, 6, 7, 8, 9, 10, 11, 13, 14 • /CAS Write Latency (CWL): 5, 6, 7, 8, 9, 10 • Precharge: auto precharge option for each burst access • Driver strength: RZQ/7, RZQ/6 (RZQ = 240Ω) • Refresh: auto-refresh, self-refresh • Refresh cycles — Average refresh period 7.8µs at 0°C ≤ TC ≤ +85°C 3.9µs at +85°C < TC ≤ +95°C • Operating case temperature range — TC = 0°C to +95°C • Double-data-rate architecture: two data transfers per clock cycle • The high-speed data transfer is realized by the 8 bits prefetch pipelined architecture • Bi-directional differential data strobe (DQS and /DQS) is transmitted/received with data for capturing data at the receiver • DQS is edge-aligned with data for READs; centeraligned with data for WRITEs • Differential clock inputs (CK and /CK) • DLL aligns DQ and DQS transitions with CK transitions • Commands entered on each positive CK edge; data and data mask referenced to both edges of DQS • Data mask (DM) for write data • Posted /CAS by programmable additive latency for better command and data bus efficiency • On-Die Termination (ODT) for better signal quality — Synchronous ODT — Dynamic ODT — Asynchronous ODT • Multi Purpose Register (MPR) for pre-defined pattern read out • ZQ calibration for DQ drive and ODT • /RESET pin for Power-up sequence and reset function • SRT range: — Normal/extended • Programmable Output driver impedance control • Seamless BL4 access with bank-grouping — Applied only for DDR3-1333 and 1600 Document. No. E1729E30 (Ver. 3.0) Date Published August 2012 (K) Japan Printed in Japan URL: http://www.elpida.com ©Elpida Memory, Inc. 2010-2012 EDJ1108DJBG, EDJ1116DJBG Ordering Information Die revision Part number EDJ1108DJBG-MU-F EDJ1108DJBG-JS-F EDJ1108DJBG-GN-F EDJ1108DJBG-DJ-F EDJ1116DJBG-MU-F EDJ1116DJBG-JS-F EDJ1116DJBG-GN-F EDJ1116DJBG-DJ-F J J Organization (words × bits) 128M × 8 64M × 16 Internal banks JEDEC speed bin (CL-tRCD-tRP) 78-ball FBGA 8 DDR3-2133L (14-14-14) DDR3-1866M (13-13-13) DDR3-1600K (11-11-11) DDR3-1333H (9-9-9) 96-ball FBGA 8 DDR3-2133L (14-14-14) DDR3-1866M (13-13-13) DDR3-1600K (11-11-11) DDR3-1333H (9-9-9) Package Part Number E D J 11 08 D J BG - MU - F Elpida Memory Type D: Packaged Device Environment code F: Lead Free (RoHS compliant) and Halogen Free Product Family J: DDR3 Density / Bank 11: 1Gb / 8-bank Speed MU: DDR3-2133L (14-14-14) JS: DDR3-1866M (13-13-13) GN: DDR3-1600K (11-11-11) DJ: DDR3-1333H (9-9-9) Organization 08: x8 16: x16 Package BG: FBGA Power Supply, Interface Die Rev. D: ,1.5V, SSTL_15 Operating Frequency Frequency (Mbps) Speed Grade CL5 -MU CL6 CL7 CL8 CL9 CL10 CL11 CL13 CL14 800 1066 1066 1333 1333 1600 1866 2133 1866 -JS 667 800 1066 1066 1333 1333 1600 -GN 667 800 1066 1066 1333 1333 1600 -DJ 667 800 1066 1066 1333 1333 speed bin (CL-tRCD-tRP) DDR3-2133 (14-14-14) DDR3-1866 (13-13-13) DDR3-1600 (11-11-11) DDR3-1333 (9-9-9) Detailed Information For detailed electrical specification and further information, please refer to the DDR3 SDRAM General Functionality and Electrical Condition data sheet (E1926E) and Addendum data sheet (E1928E). Data Sheet E1729E30 (Ver. 3.0) 2 EDJ1108DJBG, EDJ1116DJBG Pin Configurations Pin Configurations (×8 configuration) /xxx indicates active low signal. 78-ball FBGA 2 1 3 7 8 9 A VSS VDD NC NU/(/TDQS) VSS VDD B VSS VSSQ DQ0 DM/TDQS VSSQ VDDQ C VDDQ DQ2 DQS DQ1 DQ3 VSSQ VSSQ DQ6 /DQS VDD VSS VSSQ VREFDQ VDDQ DQ4 DQ7 DQ5 VDDQ D E F NC VSS /RAS CK VSS NC ODT VDD /CAS /CK VDD CKE NC /CS /WE A10(AP) ZQ NC VSS BA0 BA2 NC VDD A3 A0 VSS A5 A2 A1 A4 VSS VDD A7 A9 A11 A6 VDD VSS /RESET A13 NC A8 VSS G H J VREFCA VSS K A12(/BC) BA1 VDD L M N (Top view) Pin name Function Pin name Function A0 to A13*3 Address inputs A10(AP): Auto precharge A12(/BC): Burst chop /RESET*3 Active low asynchronous reset BA0 to BA2*3 Bank select VDD Supply voltage for internal circuit DQ0 to DQ7 Data input/output VSS Ground for internal circuit DQS, /DQS Differential data strobe VDDQ Supply voltage for DQ circuit TDQS, /TDQS Termination data strobe VSSQ Ground for DQ circuit /CS*3 Chip select VREFDQ Reference voltage for DQ Command input VREFCA Reference voltage for CA Clock enable ZQ Reference pin for ZQ calibration Differential clock input NC*1 /RAS, /CAS, /WE*3 CKE* 3 CK, /CK DM Write data mask ODT*3 ODT control Notes: 1. 2. 3. NU* 2 No connection Not usable Not internally connected with die. Don't connect. Internally connected. Input only pins (address, command, CKE, ODT and /RESET) do not supply termination. Data Sheet E1729E30 (Ver. 3.0) 3 EDJ1108DJBG, EDJ1116DJBG Pin Configurations (× 16 configuration) /xxx indicates active low signal. 96-ball FBGA 2 1 3 7 8 9 A VDDQ DQU5 DQU7 DQU4 VDDQ VSS VSSQ /DQSU DQU6 VSSQ B VDD VSS C D VDDQ DQU3 DQU1 DQSU DQU2 VDDQ VSSQ VDDQ DMU DQU0 VSSQ VDD E VSS VSSQ DQL0 DML VSSQ VDDQ F VDDQ DQL2 DQSL DQL1 DQL3 VSSQ VSSQ DQL6 /DQSL VDD G VSS VSSQ H DQL7 DQL5 VDDQ VREFDQ VDDQ DQL4 J NC VSS /RAS CK VSS NC ODT VDD /CAS /CK VDD CKE NC /CS /WE A10(AP) ZQ NC VSS BA0 BA2 NC VDD A3 A0 VSS A5 A2 A1 A4 VSS VDD A7 A9 A11 A6 VDD VSS /RESET NC NC A8 VSS K L M VREFCA VSS N A12(/BC) BA1 VDD P R T (Top view) Pin name Function Pin name Function A0 to A12*2 Address inputs A10(AP): Auto precharge A12(/BC): Burst chop /RESET*2 Active low asynchronous reset BA0 to BA2*2 Bank select VDD Supply voltage for internal circuit DQU0 to DQU7 DQL0 to DQL7 Data input/output VSS Ground for internal circuit DQSU, /DQSU DQSL, /DQSL Differential data strobe VDDQ Supply voltage for DQ circuit Chip select VSSQ Ground for DQ circuit /CS*2 2 /RAS, /CAS, /WE* Command input VREFDQ Reference voltage for DQ CKE*2 Clock enable VREFCA Reference voltage for CA CK, /CK Differential clock input ZQ Reference pin for ZQ calibration DMU, DML Write data mask NC*1 No connection ODT*2 ODT control Notes: 1. 2. Not internally connected with die. Input only pins (address, command, CKE, ODT and /RESET) do not supply termination. Data Sheet E1729E30 (Ver. 3.0) 4 EDJ1108DJBG, EDJ1116DJBG CONTENTS Specifications ........................................................................................................................................ 1 Features ................................................................................................................................................ 1 Ordering Information ............................................................................................................................. 2 Part Number .......................................................................................................................................... 2 Operating Frequency ............................................................................................................................ 2 Detailed Information .............................................................................................................................. 2 Pin Configurations ................................................................................................................................. 3 1. Electrical Conditions ...................................................................................................................... 6 1.1 1.2 1.3 1.4 2. Electrical Specifications ............................................................................................................... 19 2.1 2.2 2.3 3. DC Characteristics .......................................................................................................................... 19 Pin Capacitance .............................................................................................................................. 21 Standard Speed Bins ...................................................................................................................... 23 Package Drawing ......................................................................................................................... 29 3.1 3.2 4. Absolute Maximum Ratings ..............................................................................................................6 Operating Temperature Condition ....................................................................................................6 Recommended DC Operating Conditions ........................................................................................7 IDD and IDDQ Measurement Conditions ..........................................................................................8 78-ball FBGA .................................................................................................................................. 29 96-ball FBGA .................................................................................................................................. 30 Recommended Soldering Conditions .......................................................................................... 31 Data Sheet E1729E30 (Ver. 3.0) 5 EDJ1108DJBG, EDJ1116DJBG 1. Electrical Conditions • All voltages are referenced to VSS (GND) • Execute power-up and Initialization sequence before proper device operation is achieved. 1.1 Absolute Maximum Ratings Table 1: Absolute Maximum Ratings Parameter Symbol Rating Unit Notes Power supply voltage VDD −0.4 to +1.975 V 1, 3 Power supply voltage for output VDDQ −0.4 to +1.975 V 1, 3 Input voltage VIN −0.4 to +1.975 V 1 Output voltage VOUT −0.4 to +1.975 V 1 Reference voltage VREFCA −0.4 to 0.6 × VDD V 3 Reference voltage for DQ VREFDQ −0.4 to 0.6 × VDDQ V 3 Storage temperature Tstg −55 to +100 °C 1, 2 Power dissipation PD 1.0 W 1 Short circuit output current IOUT 50 mA 1 Notes: 1. 2. 3. Stresses greater than those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. Storage temperature is the case surface temperature on the center/top side of the DRAM. VDD and VDDQ must be within 300mV of each other at all times; and VREF must be no greater than 0.6 × VDDQ, When VDD and VDDQ are less than 500mV; VREF may be equal to or less than 300mV. Caution: Exposing the device to stress above those listed in Absolute Maximum Ratings could cause permanent damage. The device is not meant to be operated under conditions outside the limits described in the operational section of this specification. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. 1.2 Operating Temperature Condition Table 2: Operating Temperature Condition Parameter Symbol Rating Unit Notes Operating case temperature TC 0 to +95 °C 1, 2, 3 Notes: 1. 2. 3. Operating temperature is the case surface temperature on the center/top side of the DRAM. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. During operation, the DRAM case temperature must be maintained between 0°C to +85°C under all operating conditions. Some applications require operation of the DRAM in the Extended Temperature Range between +85°C and +95°C case temperature. Full specifications are guaranteed in this range, but the following additional conditions apply: a) Refresh commands must be doubled in frequency, therefore reducing the refresh interval tREFI to 3.9µs. (This double refresh requirement may not apply for some devices.) b) If Self-refresh operation is required in the Extended Temperature Range, then it is mandatory to either use the Manual Self-Refresh mode with Extended Temperature Range capability (MR2 bit [A6, A7] = [0, 1]) or enable the optional Auto Self-Refresh mode (MR2 bit [A6, A7] = [1, 0]). Data Sheet E1729E30 (Ver. 3.0) 6 EDJ1108DJBG, EDJ1116DJBG 1.3 Recommended DC Operating Conditions Table 3: Recommended DC Operating Conditions (TC = 0°C to +85°C) Parameter Symbol min typ max Unit Notes Supply voltage VDD 1.425 1.5 1.575 V 1, 2 Supply voltage for DQ VDDQ 1.425 1.5 1.575 V 1, 2 Notes: 1. 2. Under all conditions VDDQ must be less than or equal to VDD. VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together. Data Sheet E1729E30 (Ver. 3.0) 7 EDJ1108DJBG, EDJ1116DJBG 1.4 IDD and IDDQ Measurement Conditions In this chapter, IDD and IDDQ measurement conditions such as test load and patterns are defined. The figure Measurement Setup and Test Load for IDD and IDDQ Measurements shows the setup and test load for IDD and IDDQ measurements. • IDD currents (such as IDD0, IDD1, IDD2N, IDD2NT, IDD2P0, IDD2P1, IDD2Q, IDD3N, IDD3P, IDD4R, IDD4W, IDD5B, IDD6, IDD6ET, IDD6TC and IDD7) are measured as time-averaged currents with all VDD balls of the DDR3 SDRAM under test tied together. Any IDDQ current is not included in IDD currents. • IDDQ currents (such as IDDQ2NT and IDDQ4R) are measured as time-averaged currents with all VDDQ balls of the DDR3 SDRAM under test tied together. Any IDD current is not included in IDDQ currents. Note:IDDQ values cannot be directly used to calculate I/O power of the DDR3 SDRAM. They can be used to support correlation of simulated I/O power to actual I/O power as outlined in correlation from simulated channel I/O power to actual channel I/O power supported by IDDQ measurement. For IDD and IDDQ measurements, the following definitions apply: • L and 0: VIN ≤ VIL(AC)max • H and 1: VIN ≥ VIH(AC)min • MID-LEVEL: defined as inputs are VREF = VDDQ / 2 • FLOATING: don't care or floating around VREF. • Timings used for IDD and IDDQ measurement-loop patterns are provided in Timings used for IDD and IDDQ Measurement-Loop Patterns table. • Basic IDD and IDDQ measurement conditions are described in Basic IDD and IDDQ Measurement Conditions table. Note:The IDD and IDDQ measurement-loop patterns need to be executed at least one time before actual IDD or IDDQ measurement is started. • Detailed IDD and IDDQ measurement-loop patterns are described in IDD0 Measurement-Loop Pattern table through IDD7 Measurement-Loop Pattern table. • IDD Measurements are done after properly initializing the DDR3 SDRAM. This includes but is not limited to setting. RON = RZQ/7 (34Ω in MR1); Qoff = 0B (Output Buffer enabled in MR1); RTT_Nom = RZQ/6 (40Ω in MR1); RTT_WR = RZQ/2 (120Ω in MR2); TDQS Feature disabled in MR1 • Define D = {/CS, /RAS, /CAS, /WE} : = {H, L, L, L} • Define /D = {/CS, /RAS, /CAS, /WE} : = {H, H, H, H} Data Sheet E1729E30 (Ver. 3.0) 8 EDJ1108DJBG, EDJ1116DJBG IDDQ IDD VDD /RESET CK, /CK CKE /CS /RAS, /CAS, /WE VDDQ DDR3 SDRAM Address, BA ODT ZQ VSS DQS, /DQS, DQ, DM, TDQS, /TDQS RTT = 25Ω VDDQ/2 VSSQ Figure 2: Measurement Setup and Test Load for IDD and IDDQ Measurements Application specific memory channel environment Channel I/O power simulation IDDQ Test load IDDQ simulation IDDQ measurement Correlation Correction Channel I/O power number Figure 3: Correlation from Simulated Channel I/O Power to Actual Channel I/O Power Supported by IDDQ Measurement Data Sheet E1729E30 (Ver. 3.0) 9 EDJ1108DJBG, EDJ1116DJBG 1.4.1 Timings Used for IDD and IDDQ Measurement-Loop Patterns Table 4: Timings Used for IDD and IDDQ Measurement-Loop Patterns DDR3-800 DDR3-1066 DDR3-1333 DDR3-1600 Parameter 6-6-6 7-7-7 9-9-9 11-11-11 Unit CL 6 7 9 11 nCK tCK(min) 2.5 1.875 1.5 1.25 ns nRCD(min) 6 7 9 11 nCK nRC(min) 21 27 33 39 nCK nRAS(min) 15 20 24 28 nCK nRP(min) 6 7 9 11 nCK nFAW (1KB) 16 20 20 24 nCK nFAW (2KB, 4KB) 20 27 30 32 nCK nRRD (1KB) 4 4 4 5 nCK nRRD (2KB, 4KB) 4 6 5 6 nCK nRFC (1Gb) 44 59 74 88 nCK nRFC (2Gb) 64 86 107 128 nCK nRFC (4Gb) 104 139 174 208 nCK Parameter DDR3-1866 DDR3-2133 13-13-13 14-14-14 Unit CL 13 14 nCK tCK(min) 1.07 0.935 ns nRCD(min) 13 14 nCK nRC(min) 45 50 nCK nRAS(min) 32 36 nCK nRP(min) 13 14 nCK nFAW (1KB) 26 27 nCK nFAW (2KB, 4KB) 33 38 nCK nRRD (1KB) 5 6 nCK nRRD (2KB, 4KB) 6 7 nCK nRFC (1Gb) 103 118 nCK nRFC (2Gb) 150 172 nCK nRFC (4Gb) 243 279 nCK Data Sheet E1729E30 (Ver. 3.0) 10 EDJ1108DJBG, EDJ1116DJBG 1.4.2 Basic IDD and IDDQ Measurement Conditions Table 5: Basic IDD and IDDQ Measurement Conditions Parameter Symbol Description IDD0 CKE: H; External clock: on; tCK, nRC, nRAS, CL: see Table 4; BL: 8*1; AL: 0; /CS: H between ACT and PRE; Command, address, bank address inputs: partially toggling according to Table 6; Data I/O: MID-LEVEL; DM: stable at 0; Bank activity: cycling with one bank active at a time: 0,0,1,1,2,2,... (see Table 6); Output buffer and RTT: enabled in MR*2; ODT signal: stable at 0; Pattern details: see Table 6 IDD1 CKE: H; External clock: On; tCK, nRC, nRAS, nRCD, CL: see Table 4; BL: 8*1, *6; AL: 0; /CS: H between ACT, RD and PRE; Command, address, bank address inputs, data I/O: partially toggling according to Table 7; DM: stable at 0; Bank activity: cycling with one bank active at a time: 0,0,1,1,2,2,... (see Table 7); Output buffer and RTT: enabled in MR*2; ODT Signal: stable at 0; Pattern details: see Table 7 IDD2N CKE: H; External clock: on; tCK, CL: see Table 4 BL: 8*1; AL: 0; /CS: stable at 1; Command, address, bank address Inputs: partially toggling according to Table 8; data I/O: MID-LEVEL; DM: stable at 0; bank activity: all banks closed; output buffer and RTT: enabled in mode registers*2; ODT signal: stable at 0; pattern details: see Table 8 Precharge standby ODT current IDD2NT CKE: H; External clock: on; tCK, CL: see Table 4; BL: 8*1; AL: 0; /CS: stable at 1; Command, address, bank address Inputs: partially toggling according to Table 9; data I/O: MID-LEVEL; DM: stable at 0; bank activity: all banks closed; output buffer and RTT: enabled in MR*2; ODT signal: toggling according to Table 9; pattern details: see Table 9 Precharge standby ODT IDDQ current IDDQ2NT Same definition like for IDD2NT, however measuring IDDQ current instead of IDD current IDD2P0 CKE: L; External clock: on; tCK, CL: see Table 4; BL: 8*1; AL: 0; /CS: stable at 1; Command, address, bank address inputs: stable at 0; data I/O: MID-LEVEL; DM: stable at 0; bank activity: all banks closed; output buffer and RTT: EMR*2; ODT signal: stable at 0; precharge power down mode: slow exit*3 IDD2P1 CKE: L; External clock: on; tCK, CL: see Table 5; BL: 8*1; AL: 0; /CS: stable at 1; Command, address, bank address Inputs: stable at 0; data I/O: MID-LEVEL; DM:stable at 0; bank activity: all banks closed; output buffer and RTT: enabled in MR*2; ODT signal: stable at 0; precharge power down mode: fast exit*3 IDD2Q CKE: H; External clock: On; tCK, CL: see Table 4; BL: 8*1; AL: 0; /CS: stable at 1; Command, address, bank address Inputs: stable at 0; data I/O: MID-LEVEL; DM: stable at 0;bank activity: all banks closed; output buffer and RTT: enabled in MR*2; ODT signal: stable at 0 IDD3N CKE: H; External clock: on; tCK, CL: see Table 4; BL: 8*1; AL: 0; /CS: stable at 1; Command, address, bank address Inputs: partially toggling according to Table 8; data I/O: MID-LEVEL; DM: stable at 0; bank activity: all banks open; output buffer and RTT: enabled in MR*2; ODT signal: stable at 0; pattern details: see Table 8 IDD3P CKE: L; External clock: on; tCK, CL: see Table 4; BL: 8*1; AL: 0; /CS: stable at 1; Command, address, bank address inputs: stable at 0; data I/O: MID-LEVEL; DM:stable at 0; bank activity: all banks open; output buffer and RTT: enabled in MR*2; ODT signal: stable at 0 Operating burst read current IDD4R CKE: H; External clock: on; tCK, CL: see Table 4; BL: 8*1, *6; AL: 0; /CS: H between RD; Command, address, bank address Inputs: partially toggling according to Table 10; data I/O: seamless read data burst with different data between one burst and the next one according to Table 10; DM: stable at 0; bank activity: all banks open, RD commands cycling through banks: 0,0,1,1,2,2,... (see Table 10); Output buffer and RTT: enabled in MR*2; ODT signal: stable at 0; pattern details: see Table 10 Operating burst read IDDQ current IDDQ4R Same definition like for IDD4R, however measuring IDDQ current instead of IDD current Operating one bank active precharge current Operating one bank active-read-precharge current Precharge standby current Precharge power-down current slow exit Precharge power-down current fast exit Precharge quiet standby current Active standby current Active power-down current Data Sheet E1729E30 (Ver. 3.0) 11 EDJ1108DJBG, EDJ1116DJBG Table 5: Basic IDD and IDDQ Measurement Conditions (cont’d) Parameter Operating burst write current Burst refresh current Self-refresh current: normal temperature range Symbol Description IDD4W CKE: H; External clock: on; tCK, CL: see Table 4; BL: 8*1; AL: 0; /CS: H between WR; command, address, bank address inputs: partially toggling according to Table 11; data I/O: seamless write data burst with different data between one burst and the next one according to IDD4W Measurement-Loop Pattern table; DM: stable at 0; bank activity: all banks open, WR commands cycling through banks: 0,0,1,1,2,2,.. (see Table 11); Output buffer and RTT: enabled in MR*2; ODT signal: stable at H; pattern details: see Table 11 IDD5B CKE: H; External clock: on; tCK, CL, nRFC: see Table 4; BL: 8*1; AL: 0; /CS: H between REF; Command, address, bank address Inputs: partially toggling according to Table 12; data I/O: MID-LEVEL; DM: stable at 0; bank activity: REF command every nRFC (Table 12); output buffer and RTT: enabled in MR*2; ODT signal: stable at 0; pattern details: see Table 12 IDD6 TC: 0 to 85°C; ASR: disabled*4; SRT: Normal*5; CKE: L; External clock: off; CK and /CK: L; CL: see Table 4; BL: 8*1; AL: 0; /CS, command, address, bank address, data I/O: MID-LEVEL; DM: stable at 0; bank activity: Self-refresh operation; output buffer and RTT: enabled in MR*2; ODT signal: MID-LEVEL Self-refresh current: extended IDD6ET temperature range TC: 0 to 95°C; ASR: Disabled*4; SRT: Extended*5; CKE: L; External clock: off; CK and /CK: L; CL: Table 4; BL: 8*1; AL: 0; /CS, command, address, bank address, data I/O: MID-LEVEL; DM: stable at 0; bank activity: Extended temperature self-refresh operation; output buffer and RTT: enabled in MR*2; ODT signal: MID-LEVEL Auto self-refresh current (Optional) IDD6TC TC: 0 to 95°C; ASR: Enabled*4; SRT: Normal*5; CKE: L; External clock: off; CK and /CK: L; CL: Table 4; BL: 8*1; AL: 0; /CS, command, address, bank address, data I/O: MID-LEVEL; DM: stable at 0; bank activity: Auto self-refresh operation; output buffer and RTT: enabled in MR*2; ODT signal: MID-LEVEL IDD7 CKE: H; External clock: on; tCK, nRC, nRAS, nRCD, nRRD, nFAW, CL: see Table 4; BL: 8*1, *6; AL: CL-1; /CS: H between ACT and RDA; Command, address, bank address Inputs: partially toggling according to Table 13; data I/O: read data bursts with different data between one burst and the next one according to Table 13; DM: stable at 0; bank activity: two times interleaved cycling through banks (0, 1, …7) with different addressing, see Table 13; output buffer and RTT: enabled in MR*2; ODT signal: stable at 0; pattern details: see Table 13 IDD8 /RESET: low; External clock: off; CK and /CK: low; CKE: FLOATING; /CS, command, address, bank address, Data IO: FLOATING; ODT signal: FLOATING RESET low current reading is valid once power is stable and /RESET has been low for at least 1ms. Operating bank interleave read current RESET low current Notes: 1. 2. 3. 4. 5. 6. Burst Length: BL8 fixed by MRS: MR0 bits [1,0] = [0,0]. MR: Mode Register Output buffer enable: set MR1 bit A12 = 1 and MR1 bits [5, 1] = [0,1]; RTT_Nom enable: set MR1 bits [9, 6, 2] = [0, 1, 1]; RTT_WR enable: set MR2 bits [10, 9] = [1,0]. Precharge power down mode: set MR0 bit A12= 0 for Slow Exit or MR0 bit A12 = 1 for fast exit. Auto self-refresh (ASR): set MR2 bit A6 = 0 to disable or 1 to enable feature. Self-refresh temperature range (SRT): set MR0 bit A7= 0 for normal or 1 for extended temperature range. Read burst type: nibble sequential, set MR0 bit A3 = 0 Data Sheet E1729E30 (Ver. 3.0) 12 EDJ1108DJBG, EDJ1116DJBG Table 6: IDD0 Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number 0 Toggling Static H Notes: 1. 2. 3. 4. Command /CS /RAS /CAS /WE ODT A11 BA*3 -Am A10 A7 -A9 A3 -A6 A0 -A2 0 ACT 0 0 1 1 0 0 0 0 0 0 0 1, 2 D, D 1 0 0 0 0 0 0 0 0 0 0 3, 4 /D, /D 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 … Repeat pattern 1…4 until nRAS − 1, truncate if necessary nRAS PRE … Repeat pattern 1...4 until nRC − 1, truncate if necessary 1 × nRC +0 ACT 0 0 1 1 0 0 0 0 0 F 0 1 × nRC +1, 2 D, D 1 0 0 0 0 0 0 0 0 F 0 1 × nRC + 3, 4 /D, /D 1 1 1 1 0 0 0 0 0 F 0 0 0 1 0 0 0 0 … Repeat pattern nRC + 1,...,4 until 1 × nRC + nRAS − 1, truncate if necessary 1 × nRC + nRAS PRE 0 0 1 0 0 0 0 0 … Repeat nRC + 1,...,4 until 2 × nRC − 1, truncate if necessary 1 2 × nRC Repeat Sub-Loop 0, use BA= 1 instead 2 4 × nRC Repeat Sub-Loop 0, use BA= 2 instead 3 6 × nRC Repeat Sub-Loop 0, use BA= 3 instead 4 8 × nRC Repeat Sub-Loop 0, use BA= 4 instead 5 10 × nRC Repeat Sub-Loop 0, use BA= 5 instead 6 12 × nRC Repeat Sub-Loop 0, use BA= 6 instead 7 14 × nRC Repeat Sub-Loop 0, use BA= 7 instead DM must be driven low all the time. DQS, /DQS are MID-LEVEL. DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Data Sheet E1729E30 (Ver. 3.0) 13 0 F 0 Data*2 EDJ1108DJBG, EDJ1116DJBG Table 7: IDD1 Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number 0 Toggling Static H Notes: 1. 2. 3. 4. Command /CS /RAS /CAS /WE ODT A11 BA*3 -Am A10 A7 A3 A0 -A9 -A6 -A2 Data*2 0 ACT 0 0 1 1 0 0 0 0 0 0 0 ⎯ 1, 2 D, D 1 0 0 0 0 0 0 0 0 0 0 ⎯ 3, 4 /D, /D 1 1 1 1 0 0 0 0 0 0 0 ⎯ 0 0 0 0 00000000 0 0 0 0 ⎯ … Repeat pattern 1...4 until nRCD − 1, truncate if necessary nRCD RD … Repeat pattern 1...4 until nRAS − 1, truncate if necessary nRAS PRE … Repeat pattern 1...4 until nRC − 1, truncate if necessary 1 × nRC +0 ACT 0 0 1 1 0 0 0 0 0 F 0 ⎯ 1 × nRC + 1, 2 D, D 1 0 0 0 0 0 0 0 0 F 0 ⎯ 1 × nRC + 3, 4 /D, /D 1 1 1 1 0 0 0 0 0 F 0 ⎯ 0 00110011 0 ⎯ 0 0 1 0 0 1 1 0 0 0 0 0 0 0 … Repeat pattern nRC + 1,..., 4 until nRC + nRCD − 1, truncate if necessary 1 × nRC + nRCD RD … Repeat pattern nRC + 1,..., 4 until nRC +nRAS − 1, truncate if necessary 1 × nRC + nRAS PRE 0 0 1 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 … Repeat pattern nRC + 1,..., 4 until 2 × nRC − 1, truncate if necessary 1 2 × nRC Repeat Sub-Loop 0, use BA= 1 instead 2 4 × nRC Repeat Sub-Loop 0, use BA= 2 instead 3 6 × nRC Repeat Sub-Loop 0, use BA= 3 instead 4 8 × nRC Repeat Sub-Loop 0, use BA= 4 instead 5 10 × nRC Repeat Sub-Loop 0, use BA= 5 instead 6 12 × nRC Repeat Sub-Loop 0, use BA= 6 instead 7 14 × nRC Repeat Sub-Loop 0, use BA= 7 instead F F DM must be driven low all the time. DQS, /DQS are used according to read commands, otherwise MID-LEVEL. Burst sequence driven on each DQ signal by read command. Outside burst operation, DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Data Sheet E1729E30 (Ver. 3.0) 14 EDJ1108DJBG, EDJ1116DJBG Table 8: IDD2N and IDD3N Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number 0 /RAS /CAS /WE ODT A11 BA*3 -Am A10 A7 -A9 A3 -A6 A0 -A2 0 D 1 0 0 0 0 0 0 0 0 0 0 1 D 1 0 0 0 0 0 0 0 0 0 0 2 /D 1 1 1 1 0 0 0 0 0 F 0 1 1 1 1 0 0 0 0 0 F 0 3 /D 4 to 7 Repeat Sub-Loop 0, use BA= 1 instead 8 to 11 Repeat Sub-Loop 0, use BA= 2 instead 3 12 to 15 Repeat Sub-Loop 0, use BA= 3 instead 4 16 to 19 Repeat Sub-Loop 0, use BA= 4 instead 5 20 to 23 Repeat Sub-Loop 0, use BA= 5 instead 6 24 to 27 Repeat Sub-Loop 0, use BA= 6 instead 7 28 to 31 Repeat Sub-Loop 0, use BA= 7 instead 1 Toggling Static H 2 Notes: 1. 2. 3. 4. Command /CS Data*2 DM must be driven low all the time. DQS, /DQS are MID-LEVEL. DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Table 9: IDD2NT and IDDQ2NT Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number 0 /RAS /CAS /WE ODT A11 BA*3 -Am A10 A7 -A9 A3 -A6 A0 -A2 0 D 1 0 0 0 0 0 0 0 0 0 0 1 D 1 0 0 0 0 0 0 0 0 0 0 2 /D 1 1 1 1 0 0 0 0 0 F 0 1 1 1 1 0 0 0 0 0 F 0 3 /D 4 to 7 Repeat Sub-Loop 0, but ODT = 0 and BA= 1 8 to 11 Repeat Sub-Loop 0, but ODT = 1 and BA= 2 3 12 to 15 Repeat Sub-Loop 0, but ODT = 1 and BA= 3 4 16 to 19 Repeat Sub-Loop 0, but ODT = 0 and BA= 4 5 20 to 23 Repeat Sub-Loop 0, but ODT = 0 and BA= 5 6 24 to 27 Repeat Sub-Loop 0, but ODT = 1 and BA= 6 7 28 to 31 Repeat Sub-Loop 0, but ODT = 1 and BA= 7 1 Toggling Static H 2 Notes: 1. 2. 3. 4. Command /CS DM must be driven low all the time. DQS, /DQS are MID-LEVEL. DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Data Sheet E1729E30 (Ver. 3.0) 15 Data*2 EDJ1108DJBG, EDJ1116DJBG Table 10: IDD4R and IDDQ4R Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number 0 Toggling Static H 1 Notes: 1. 2. 3. 4. Command /CS /RAS /CAS /WE ODT A11 BA*3 -Am A7 A10 -A9 A3 -A6 A0 -A2 Data*2 0 RD 0 1 0 1 0 0 0 0 0 0 0 00000000 1 D 1 0 0 0 0 0 0 0 0 0 0 ⎯ 2,3 /D, /D 1 1 1 1 0 0 0 0 0 0 0 ⎯ 4 RD 0 1 0 1 0 0 0 0 0 F 0 00110011 5 D 1 0 0 0 0 0 0 0 0 F 0 ⎯ 6,7 /D, /D 1 1 1 1 0 0 0 0 0 F 0 ⎯ 8 to 15 Repeat Sub-Loop 0, but BA= 1 2 16 to 23 Repeat Sub-Loop 0, but BA= 2 3 24 to 31 Repeat Sub-Loop 0, but BA= 3 4 32 to 39 Repeat Sub-Loop 0, but BA= 4 5 40 to 47 Repeat Sub-Loop 0, but BA= 5 6 48 to 55 Repeat Sub-Loop 0, but BA= 6 7 56 to 63 Repeat Sub-Loop 0, but BA= 7 DM must be driven low all the time. DQS, /DQS are used according to read commands, otherwise MID-LEVEL. Burst sequence driven on each DQ signal by read command. Outside burst operation, DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Data Sheet E1729E30 (Ver. 3.0) 16 EDJ1108DJBG, EDJ1116DJBG Table 11: IDD4W Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number 0 Toggling Static H 1 Notes: 1. 2. 3. 4. Command /CS /RAS /CAS /WE ODT A11 BA*3 -Am A7 A10 -A9 A3 -A6 A0 -A2 Data*2 0 WR 0 1 0 0 1 0 0 0 0 0 0 00000000 1 D 1 0 0 0 1 0 0 0 0 0 0 ⎯ 2,3 /D, /D 1 1 1 1 1 0 0 0 0 0 0 ⎯ 4 WR 0 1 0 0 1 0 0 0 0 F 0 00110011 5 D 1 0 0 0 1 0 0 0 0 F 0 ⎯ 6,7 /D, /D 1 1 1 1 1 0 0 0 0 F 0 ⎯ 8 to 15 Repeat Sub-Loop 0, but BA= 1 2 16 to 23 Repeat Sub-Loop 0, but BA= 2 3 24 to 31 Repeat Sub-Loop 0, but BA= 3 4 32 to 39 Repeat Sub-Loop 0, but BA= 4 5 40 to 47 Repeat Sub-Loop 0, but BA= 5 6 48 to 55 Repeat Sub-Loop 0, but BA= 6 7 56 to 63 Repeat Sub-Loop 0, but BA= 7 DM must be driven low all the time. DQS, /DQS are used according to write commands, otherwise MID-LEVEL. Burst sequence driven on each DQ signal by write command. Outside burst operation, DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Table 12: IDD5B Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number Command /CS /RAS /CAS /WE ODT A11 BA*3 -Am A7 A10 -A9 A3 -A6 A0 -A2 Data*2 REF 0 0 0 1 0 0 0 0 0 0 0 ⎯ 1, 2 D 1 0 0 0 0 0 0 0 0 0 0 ⎯ 3,4 /D, /D 1 1 1 1 0 0 0 0 0 F 0 ⎯ 5 to 8 Repeat cycles 1...4, but BA= 1 0 0 Toggling Static H 1 2 Notes: 1. 2. 3. 4. 9 to 12 Repeat cycles 1...4, but BA= 2 13 to 16 Repeat cycles 1...4, but BA= 3 17 to 20 Repeat cycles 1...4, but BA= 4 21 to 24 Repeat cycles 1...4, but BA= 5 25 to 28 Repeat cycles 1...4, but BA= 6 29 to 32 Repeat cycles 1...4, but BA= 7 33 to Repeat Sub-Loop 1, until nRFC − 1. Truncate, if necessary. nRFC − 1 DM must be driven low all the time. DQS, /DQS are MID-LEVEL. DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Data Sheet E1729E30 (Ver. 3.0) 17 EDJ1108DJBG, EDJ1116DJBG Table 13: IDD7 Measurement-Loop Pattern CK, /CK CKE Sub Cycle -Loop number 0 /CS /RAS /CAS /WE ODT A11 BA*3 -Am A7 A3 A0 A10 -A9 -A6 -A2 Data*2 0 ACT 0 0 1 1 0 0 0 0 0 0 0 ⎯ 1 RDA 0 1 0 1 0 0 0 1 0 0 0 00000000 2 D 1 0 0 0 0 0 0 0 0 0 0 ⎯ … Repeat above D Command until nRRD − 1 nRRD ACT 0 0 1 1 0 1 0 0 0 F 0 ⎯ nRRD + 1 RDA 0 1 0 1 0 1 0 1 0 F 0 00110011 nRRD + 2 D 1 0 0 0 0 1 0 0 0 F 0 ⎯ … Repeat above D Command until 2 × nRRD − 1 2 2 × nRRD Repeat Sub-Loop 0, but BA= 2 3 3 × nRRD 0 0 0 F 0 ⎯ 0 ⎯ 1 Repeat Sub-Loop 1, but BA= 3 D 1 0 0 0 0 3 4 4 × nRRD 5 nFAW Repeat Sub-Loop 0, but BA= 4 6 nFAW + nRRD Repeat Sub-Loop 1, but BA= 5 7 nFAW Repeat Sub-Loop 0, but BA= 6 + 2 × nRRD 8 nFAW Repeat Sub-Loop 1, but BA= 7 + 3 × nRRD 9 D 1 0 0 0 0 7 0 0 0 F nFAW + 4 × nRRD Assert and repeat above D Command until 2 × nFAW − 1, if necessary Toggling Static H 10 ACT 0 0 1 1 0 0 0 0 0 F 0 ⎯ 2 × nFAW +1 RDA 0 1 0 1 0 0 0 1 0 F 0 00110011 D 1 0 0 0 0 0 0 0 0 F 0 ⎯ 2 × nFAW + nRRD 11 Assert and repeat above D Command until nFAW − 1, if necessary 2 × nFAW +0 2 × nFAW +2 Notes: 1. 2. 3. 4. Command Repeat above D Command until 2 × nFAW + nRRD − 1 ACT 0 0 1 1 0 1 0 0 0 0 0 ⎯ 2 × nFAW RDA + nRRD + 1 0 1 0 1 0 1 0 1 0 0 0 00000000 1 0 0 0 0 1 0 0 2 × nFAW D + nRRD + 2 Repeat above D Command until 2 × nFAW + 2 × nRRD − 1 0 0 0 ⎯ 0 ⎯ 0 ⎯ 12 2 × nFAW Repeat Sub-Loop 10, but BA= 2 +2 × nRRD 13 2 × nFAW Repeat Sub-Loop 11, but BA= 3 + 3 × nRRD 14 1 0 0 0 0 3 0 0 0 0 2 × nFAW D + 4 × nRRD Assert and repeat above D Command until 3 × nFAW − 1, if necessary 15 3 × nFAW Repeat Sub-Loop 10, but BA= 4 16 3 × nFAW +nRRD Repeat Sub-Loop 11, but BA= 5 17 3 × nFAW Repeat Sub-Loop 10, but BA= 6 + 2 × nRRD 18 3 × nFAW Repeat Sub-Loop 11, but BA= 7 + 3 × nRRD 19 1 0 0 0 0 7 0 0 0 0 3 × nFAW D + 4 × nRRD Assert and repeat above D Command until 4 × nFAW − 1, if necessary DM must be driven low all the time. DQS, /DQS are used according to read commands, otherwise MID-LEVEL. Burst sequence driven on each DQ signal by read command. Outside burst operation, DQ signals are MID-LEVEL. BA: BA0 to BA2. Am: m means Most Significant Bit (MSB) of Row address. Data Sheet E1729E30 (Ver. 3.0) 18 EDJ1108DJBG, EDJ1116DJBG 2. 2.1 Electrical Specifications DC Characteristics Table 14: DC Characteristics 1 (TC = 0°C to +85°C, VDD, VDDQ = 1.5V ± 0.075V) Data rate ×8 × 16 Symbol (Mbps) max max Unit IDD0 1333 1600 1866 2133 48 52 TBD TBD 55 60 TBD TBD mA IDD1 1333 1600 1866 2133 60 65 TBD TBD 70 75 TBD TBD mA IDD2P1 1333 1600 1866 2133 20 20 TBD TBD 20 20 TBD TBD mA Fast PD Exit IDD2P0 1333 1600 1866 2133 10 10 TBD TBD 10 10 TBD TBD mA Slow PD Exit IDD2N 1333 1600 1866 2133 30 30 TBD TBD 30 30 TBD TBD mA IDD2NT 1333 1600 1866 2133 30 32 TBD TBD 30 32 TBD TBD mA IDD2Q 1333 1600 1866 2133 30 30 TBD TBD 30 30 TBD TBD mA Active power-down current IDD3P (Always fast exit) 1333 1600 1866 2133 25 25 TBD TBD 25 26 TBD TBD mA Active standby current IDD3N 1333 1600 1866 2133 40 45 TBD TBD 40 45 TBD TBD mA IDD4R 1333 1600 1866 2133 90 105 TBD TBD 105 120 TBD TBD mA IDD4W 1333 1600 1866 2133 100 115 TBD TBD 135 155 TBD TBD mA IDD5B 1333 1600 1866 2133 135 140 TBD TBD 135 140 TBD TBD mA Parameter Operating current (ACT-PRE) Operating current (ACT-RD-PRE) Precharge power-down standby current Precharge standby current Precharge standby ODT current Precharge quiet standby current Operating current (Burst read operating) Operating current (Burst write operating) Burst refresh current Data Sheet E1729E30 (Ver. 3.0) 19 Notes EDJ1108DJBG, EDJ1116DJBG Table 14: DC Characteristics 1 (TC = 0°C to +85°C, VDD, VDDQ = 1.5V ± 0.075V)(cont’d) Data rate ×8 × 16 Symbol (Mbps) max max Unit All bank interleave read current IDD7 1333 1600 1866 2133 160 160 TBD TBD 165 190 TBD TBD mA RESET low current IDD8 10 10 mA Parameter Notes Table 15: Self-Refresh Current (TC = 0°C to +85°C, VDD, VDDQ = 1.5V ± 0.075V) Parameter Symbol max Unit Self-refresh current normal temperature range IDD6 10 mA Self-refresh current extended temperature range IDD6ET 12 mA Auto self-refresh current (Optional) IDD6TC ⎯ mA Data Sheet E1729E30 (Ver. 3.0) 20 Notes EDJ1108DJBG, EDJ1116DJBG 2.2 Pin Capacitance Table 16: Pin Capacitance [DDR3-800 to 1600] (TC = 25°C, VDD, VDDQ = 1.5V ± 0.075V) DDR3-800 DDR3-1066 DDR3-1333 DDR3-1600 Min Max Min Max Min Max Min Max Units Notes Input/output capacitance CIO 1.4 3.0 1.4 2.7 1.4 2.5 1.4 2.3 pF 1, 2 Input capacitance, CK and /CK 0.8 1.6 0.8 1.6 0.8 1.4 0.8 1.4 pF 2 Input capacitance delta, CDCK CK and /CK 0 0.15 0 0.15 0 0.15 0 0.15 pF 2, 3 Input/output capacitance delta, CDDQS DQS and /DQS 0 0.2 0 0.2 0 0.15 0 0.15 pF 2, 4 Input capacitance, (control, address, command, input-only pins) 0.75 1.4 0.75 1.35 0.75 1.3 0.75 1.3 pF 2, 5 Input capacitance delta, (All control input-only CDI_CTRL −0.5 pins) 0.3 −0.5 0.3 −0.4 0.2 −0.4 0.2 pF 2, 6, 7 Input capacitance delta, CDI_ADD_ −0.5 (All addres/command CMD input-only pins) 0.5 −0.5 0.5 −0.4 0.4 −0.4 0.4 pF 2, 8, 9 Input/output capacitance delta, DQ,DM, DQS, CDIO /DQS, TDQS, /TDQS −0.5 0.3 −0.5 0.3 −0.5 0.3 −0.5 0.3 pF 2, 10 Input/output capacitance CZQ of ZQ pin ⎯ 3 ⎯ 3 ⎯ 3 ⎯ 3 pF 2, 11 Parameter Symbol CCK CI Table 17: Pin Capacitance [DDR3-1866 to 2133] (TC = 25°C, VDD, VDDQ = 1.5V ± 0.075V) DDR3-1866 DDR3-2133 Parameter Symbol Min Max Min Max Units Notes Input/output capacitance CIO 1.4 2.2 1.4 2.1 pF 1, 2 Input capacitance, CK and /CK CCK 0.8 1.3 0.8 1.3 pF 2 Input capacitance delta, CK and /CK CDCK 0 0.15 0 0.15 pF 2, 3 Input/output capacitance delta, DQS and /DQS CDDQS 0 0.15 0 0.15 pF 2, 4 Input capacitance, (control, address, command, input- CI only pins) 0.75 1.2 0.75 1.2 pF 2, 5 Input capacitance delta, (All control input-only pins) CDI_CTRL −0.4 0.2 −0.4 0.2 pF 2, 6, 7 Input capacitance delta, (All addres/command input-only pins) CDI_ADD_CMD −0.4 0.4 −0.4 0.4 pF 2, 8, 9 Input/output capacitance delta, DQ,DM, DQS, /DQS, TDQS, /TDQS CDIO −0.5 0.3 −0.5 0.3 pF 2, 10 ⎯ 3 ⎯ 3 pF 2, 11 Input/output capacitance of ZQ pin CZQ Data Sheet E1729E30 (Ver. 3.0) 21 EDJ1108DJBG, EDJ1116DJBG Notes: 1. 2. Although the DM, TDQS and /TDQS pins have different functions, the loading matches DQ and DQS. VDD, VDDQ, VSS, VSSQ applied and all other pins floating (except the pin under test, CKE, /RESET and ODT as necessary). VDD = VDDQ = 1.5V, VBIAS=VDD/2 and ondie termination off. 3. Absolute value of CCK-C/CK. 4. Absolute value of CIO(DQS)-CIO(/DQS). 5. CI applies to ODT, /CS, CKE, A0-A15, BA0-BA2, /RAS, /CAS and /WE. 6. CDI_CTRL applies to ODT, /CS and CKE. 7. CDI_CTRL = CI(CTRL) − 0.5 × (CI(CK)+CI(/CK)). 8. CDI_ADD_CMD applies to A0-A15, BA0-BA2, /RAS, /CAS and /WE. 9. CDI_ADD_CMD = CI(ADD_CMD) − 0.5 × (CI(CK)+CI(/CK)). 10. CDIO=CIO(DQ,DM) − 0.5 × (CIO(DQS)+CIO(/DQS)). 11. Maximum external load capacitance on ZQ pin: 5pF. Data Sheet E1729E30 (Ver. 3.0) 22 EDJ1108DJBG, EDJ1116DJBG 2.3 Standard Speed Bins Table 18: DDR3-800 Speed Bins Speed Bin DDR3-800E CL-tRCD-tRP 6-6-6 Symbol min max Unit Notes tAA /CAS write latency 15 20 ns 11 tRCD 15 ⎯ ns 11 tRP 15 ⎯ ns 11 tRC 52.5 ⎯ ns 11 37.5 9 × tREFI ns 10 tCK(avg) @CL=5 CWL = 5 3.0 3.3 ns 1, 2, 3, 12 tCK(avg) @CL=6 CWL = 5 2.5 3.3 ns 1, 2, 3, 12 tRAS Supported CL settings Supported CWL settings 5, 6 nCK 5 nCK Table 19: DDR3-1066 Speed Bins Speed Bin DDR3-1066F CL-tRCD-tRP 7-7-7 Symbol /CAS write latency tAA min max Unit Notes 13.125 20 ns 11 tRCD 13.125 ⎯ ns 11 tRP 13.125 ⎯ ns 11 tRC 50.625 ⎯ ns 11 37.5 9 × tREFI ns 10 CWL = 5 3.0 3.3 ns 1, 2, 3, 4, 5, 12 CWL = 6 Reserved Reserved ns 4 CWL = 5 2.5 3.3 ns 1, 2, 3, 5 CWL = 6 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 < 2.5 ns 1, 2, 3, 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 < 2.5 ns 1, 2, 3 tRAS tCK(avg) @CL=5 tCK(avg) @CL=6 tCK(avg) @CL=7 tCK(avg) @CL=8 Supported CL settings Supported CWL settings Data Sheet E1729E30 (Ver. 3.0) 23 5, 6, 7, 8 nCK 5, 6 nCK EDJ1108DJBG, EDJ1116DJBG Table 20: DDR3-1333 Speed Bins Speed Bin DDR3-1333H CL-tRCD-tRP 9-9-9 Symbol min max Unit Notes tAA 13.5 (13.125) 20 ns 11 tRCD 13.5 (13.125) ⎯ ns 11 tRP 13.5 (13.125) ⎯ ns 11 tRC 49.5 (49.125) ⎯ ns 11 tRAS 36 9 × tREFI ns 10 CWL = 5 3.0 3.3 ns 1, 2, 3, 4, 6, 12 CWL = 6, 7 Reserved Reserved ns 4 CWL = 5 2.5 3.3 ns 1, 2, 3, 6 CWL = 6 Reserved Reserved ns 4 CWL = 7 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 < 2.5 ns 1, 2, 3, 4, 6 CWL = 7 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 < 2.5 ns 1, 2, 3, 6 CWL = 7 Reserved Reserved ns 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 < 1.875 ns 1, 2, 3, 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 < 1.875 ns 1, 2, 3 tCK(avg) @CL=5 tCK(avg) @CL=6 tCK(avg) @CL=7 tCK(avg) @CL=8 tCK(avg) @CL=9 tCK(avg) @CL=10 /CAS write latency Supported CL settings Supported CWL settings Data Sheet E1729E30 (Ver. 3.0) 24 5, 6, 7, 8, 9, 10 nCK 5, 6, 7 nCK EDJ1108DJBG, EDJ1116DJBG Table 21: DDR3-1600 Speed Bins Speed Bin DDR3-1600K CL-tRCD-tRP Symbol 11-11-11 min max Unit Notes tAA 13.75 (13.125) 20 ns 11 tRCD 13.75 (13.125) ⎯ ns 11 tRP 13.75 (13.125) ⎯ ns 11 tRC 48.75 (48.125) ⎯ ns 11 tRAS 35 9 × tREFI ns 10 tCK(avg) @CL=5 tCK(avg) @CL=6 tCK(avg) @CL=7 tCK(avg) @CL=8 tCK(avg) @CL=9 tCK(avg) @CL=10 tCK(avg) @CL=11 /CAS write latency CWL = 5 3.0 3.3 ns 1, 2, 3, 4, 7, 12 CWL = 6, 7, 8 Reserved Reserved ns 4 CWL = 5 2.5 3.3 ns 1, 2, 3, 7 CWL = 6 Reserved Reserved ns 4 CWL = 7, 8 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 < 2.5 ns 1, 2, 3, 4, 7 CWL = 7 Reserved Reserved ns 4 CWL = 8 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 < 2.5 ns 1, 2, 3, 7 CWL = 7 Reserved Reserved ns 4 CWL = 8 Reserved Reserved ns 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 < 1.875 ns 1, 2, 3, 4, 7 CWL= 8 Reserved Reserved ns 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 < 1.875 ns 1, 2, 3, 7 CWL= 8 Reserved Reserved ns 4 CWL = 5, 6, 7 Reserved Reserved ns 4 CWL= 8 1.25 < 1.5 ns 1, 2, 3 Supported CL settings Supported CWL settings Data Sheet E1729E30 (Ver. 3.0) 25 5, 6, 7, 8, 9, 10, 11 nCK 5, 6, 7, 8 nCK EDJ1108DJBG, EDJ1116DJBG Table 22: DDR3-1866 Speed Bins Speed Bin DDR3-1866M CL-tRCD-tRP Symbol 13-13-13 /CAS write latency min max Unit tAA 13.91 20.0 ns tRCD 13.91 ⎯ ns tRP 13.91 ⎯ ns tRC 47.91 ⎯ ns tRAS 34.0 9 × tREFI ns tCK(avg) @CL=5 tCK(avg) @CL=6 tCK(avg) @CL=7 tCK(avg) @CL=8 tCK(avg) @CL=9 tCK(avg) @CL=10 tCK(avg) @CL=11 tCK(avg) @CL=12 tCK(avg) @CL=13 Notes 10 CWL = 5 3.0 3.3 ns 1, 2, 3, 8 CWL = 6, 7, 8, 9 Reserved Reserved ns 4 CWL = 5 2.5 3.3 ns 1, 2, 3, 8 CWL = 6 Reserved Reserved ns 4 CWL = 7, 8, 9 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 2.5 ns 1, 2, 3, 8 CWL = 7, 8, 9 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 2.5 ns 1, 2, 3, 8 CWL = 7 Reserved Reserved ns 4 CWL = 8, 9 Reserved Reserved ns 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 1.875 ns 1, 2, 3, 8 CWL= 8 Reserved Reserved ns 4 CWL= 9 Reserved Reserved ns 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 1.875 ns 1, 2, 3, 8 CWL= 8 Reserved Reserved ns 4 CWL = 5, 6, 7 Reserved Reserved ns 4 CWL= 8 1.25 1.5 ns 1, 2, 3, 8 CWL= 9 Reserved Reserved ns 4 CWL = 5, 6, 7, 8 Reserved Reserved ns 4 CWL= 9 Reserved Reserved ns 4 CWL = 5, 6, 7, 8 Reserved Reserved ns 4 CWL= 9 1.07 1.25 ns 4 5, 6, 7, 8, 9, 10, 11, 13 nCK 1, 2, 3, 8 5, 6, 7, 8, 9 nCK Supported CL settings Supported CWL settings Data Sheet E1729E30 (Ver. 3.0) 26 EDJ1108DJBG, EDJ1116DJBG Table 23: DDR3-2133 Speed Bins Speed Bin DDR3-2133L CL-tRCD-tRP Symbol 14-14-14 min max Unit tAA 13.09 20.0 ns tRCD 13.09 ⎯ ns tRP 13.09 ⎯ ns tRC 46.09 ⎯ ns tRAS 33.0 9 × tREFI ns tCK(avg) @CL=5 tCK(avg) @CL=6 tCK(avg) @CL=7 tCK(avg) @CL=8 tCK(avg) @CL=9 tCK(avg) @CL=10 tCK(avg) @CL=11 tCK(avg) @CL=12 tCK(avg) @CL=13 tCK(avg) @CL=14 /CAS write latency Notes 10 CWL = 5 Reserved Reserved ns 4 CWL = 6, 7, 8, 9, 10 Reserved Reserved ns 4 CWL = 5 2.5 3.3 ns 1, 2, 3, 9 CWL = 6 Reserved Reserved ns 4 CWL = 7, 8, 9, 10 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 2.5 ns 1, 2, 3, 9 CWL = 7 Reserved Reserved ns 4 CWL = 8, 9, 10 Reserved Reserved ns 4 CWL = 5 Reserved Reserved ns 4 CWL = 6 1.875 2.5 ns 1, 2, 3, 9 CWL = 7 Reserved Reserved ns 4 CWL = 8, 9, 10 Reserved Reserved ns 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 1.875 ns 1, 2, 3, 9 CWL= 8 Reserved Reserved ns 4 CWL= 9, 10 Reserved Reserved ns 4 CWL = 5, 6 Reserved Reserved ns 4 CWL= 7 1.5 1.875 ns 1, 2, 3, 9 CWL= 8 Reserved Reserved ns 4 CWL= 9 Reserved Reserved ns 4 CWL= 10 Reserved Reserved ns 4 CWL = 5, 6, 7 Reserved Reserved ns 4 CWL= 8 1.25 1.5 ns 1, 2, 3, 9 CWL= 9 Reserved Reserved ns 4 CWL= 10 Reserved Reserved ns 4 CWL = 5, 6, 7, 8 Reserved Reserved ns 4 CWL= 9 Reserved Reserved ns 4 CWL= 10 Reserved Reserved ns 4 CWL = 5, 6, 7, 8 Reserved Reserved ns 4 CWL= 9 1.07 1.25 ns 4 CWL= 10 Reserved Reserved ns 4 CWL = 5, 6, 7, 8, 9 Reserved Reserved ns 4 CWL= 10 0.938 1.07 ns 1, 2, 3, 9 Supported CL settings Supported CWL settings Data Sheet E1729E30 (Ver. 3.0) 27 6, 7, 8, 9, 10, 11, 13, 14 nCK 5, 6, 7, 8, 9, 10 nCK EDJ1108DJBG, EDJ1116DJBG Notes: 1. The CL setting and CWL setting result in tCK(avg)min and tCK(avg)max requirements. When making a selection of tCK(avg), both need to be fulfilled: Requirements from CL setting as well as requirements from CWL setting. 2. tCK(avg)min limits: Since /CAS latency is not purely analog - data and strobe output are synchronized by the DLL - all possible intermediate frequencies may not be guaranteed. An application should use the next smaller JEDEC standard tCK(avg) value (3.0, 2.5, 1.875, 1.5, or 1.25ns) when calculating CL(nCK) = tAA(ns) / tCK(avg)(ns), rounding up to the next ‘Supported CL’. 3. tCK(avg)max limits: Calculate tCK(avg) + tAA(max)/CL selected and round the resulting tCK(avg) down to the next valid speed bin (i.e. 3.3ns or 2.5ns or 1.875ns or 1.25ns). This result is tCK(avg)max corresponding to CL selected. 4. Reserved’ settings are not allowed. User must program a different value. 5. Any DDR3-1066 speed bin also supports functional operation at lower frequencies as shown in the table DDR3-1066 Speed Bins which are not subject to production tests but verified by design/characterization. 6. Any DDR3-1333 speed bin also supports functional operation at lower frequencies as shown in the table DDR3-1333 Speed Bins which is not subject to production tests but verified by design/characterization. 7. Any DDR3-1600 speed bin also supports functional operation at lower frequencies as shown in the table DDR3-1600 Speed Bins which is not subject to production tests but verified by design/characterization. 8. Any DDR3-1866 speed bin also supports functional operation at lower frequencies as shown in the table DDR3-1866 Speed Bins which is not subject to production tests but verified by design/characterization. 9. Any DDR3-2133 speed bin also supports functional operation at lower frequencies as shown in the table DDR3-2133 Speed Bins which is not subject to production tests but verified by design/characterization. 10. tREFI depends on operating case temperature (TC). 11. For devices supporting optional down binning to CL = 7 and CL = 9, tAA/tRCD/tRP(min) must be 13.125 ns or lower. SPD settings must be programmed to match. 12. DDR3-800 AC timing apply if DRAM operates at lower than 800 MT/s data rate. Data Sheet E1729E30 (Ver. 3.0) 28 EDJ1108DJBG, EDJ1116DJBG 3. 3.1 Package Drawing 78-ball FBGA Solder ball: Lead free (Sn-Ag-Cu) Unit: mm 7.50 ± 0.10 INDEX MARK 11.00 ± 0.10 0.20 S B 0.20 S A 0.20 S 1.20 max. S 0.35 ± 0.05 0.10 S 78-φ0.45 ± 0.05 φ0.15 M S A B 0.8 B INDEX MARK 9.6 A 1.6 0.8 6.4 ECA-TS2-0383-01 Data Sheet E1729E30 (Ver. 3.0) 29 EDJ1108DJBG, EDJ1116DJBG 3.2 96-ball FBGA Solder ball: Lead free (Sn-Ag-Cu) Unit: mm 7.50 ± 0.10 0.20 S B 13.50 ± 0.10 INDEX MARK 0.20 S A 0.20 S 1.20 max. S 0.35 ± 0.05 0.10 S B φ0.15 M S A B 0.8 96-φ0.45 ± 0.05 0.4 12.0 A INDEX MARK 1.6 0.8 6.4 ECA-TS2-0384-01 Data Sheet E1729E30 (Ver. 3.0) 30 EDJ1108DJBG, EDJ1116DJBG 4. Recommended Soldering Conditions Please consult with our sales offices for soldering conditions of the 1G bits DDR3 SDRAM. Type of Surface Mount Device EDJ1108DJBG: 78-ball FBGA < Lead free (Sn-Ag-Cu) > EDJ1116DJBG: 96-ball FBGA < Lead free (Sn-Ag-Cu) > Data Sheet E1729E30 (Ver. 3.0) 31 EDJ1108DJBG, EDJ1116DJBG NOTES FOR CMOS DEVICES 1 PRECAUTION AGAINST ESD FOR MOS DEVICES Exposing the MOS devices to a strong electric field can cause destruction of the gate oxide and ultimately degrade the MOS devices operation. Steps must be taken to stop generation of static electricity as much as possible, and quickly dissipate it, when once it has occurred. Environmental control must be adequate. When it is dry, humidifier should be used. It is recommended to avoid using insulators that easily build static electricity. MOS devices must be stored and transported in an anti-static container, static shielding bag or conductive material. All test and measurement tools including work bench and floor should be grounded. The operator should be grounded using wrist strap. MOS devices must not be touched with bare hands. Similar precautions need to be taken for PW boards with semiconductor MOS devices on it. 2 HANDLING OF UNUSED INPUT PINS FOR CMOS DEVICES No connection for CMOS devices input pins can be a cause of malfunction. If no connection is provided to the input pins, it is possible that an internal input level may be generated due to noise, etc., hence causing malfunction. CMOS devices behave differently than Bipolar or NMOS devices. Input levels of CMOS devices must be fixed high or low by using a pull-up or pull-down circuitry. Each unused pin should be connected to VDD or GND with a resistor, if it is considered to have a possibility of being an output pin. The unused pins must be handled in accordance with the related specifications. 3 STATUS BEFORE INITIALIZATION OF MOS DEVICES Power-on does not necessarily define initial status of MOS devices. Production process of MOS does not define the initial operation status of the device. Immediately after the power source is turned ON, the MOS devices with reset function have not yet been initialized. Hence, power-on does not guarantee output pin levels, I/O settings or contents of registers. MOS devices are not initialized until the reset signal is received. Reset operation must be executed immediately after power-on for MOS devices having reset function. CME0107 Data Sheet E1729E30 (Ver. 3.0) 32 EDJ1108DJBG, EDJ1116DJBG The information in this document is subject to change without notice. Before using this document, confirm that this is the latest version. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Elpida Memory, Inc. Elpida Memory, Inc. does not assume any liability for infringement of any intellectual property rights (including but not limited to patents, copyrights, and circuit layout licenses) of Elpida Memory, Inc. or third parties by or arising from the use of the products or information listed in this document. No license, express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of Elpida Memory, Inc. or others. Descriptions of circuits, software and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples. The incorporation of these circuits, software and information in the design of the customer's equipment shall be done under the full responsibility of the customer. Elpida Memory, Inc. assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits, software and information. [Product applications] Be aware that this product is for use in typical electronic equipment for general-purpose applications. Elpida Memory, Inc. makes every attempt to ensure that its products are of high quality and reliability. However, this product is not intended for use in the product in aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment, medical equipment for life support, or other such application in which especially high quality and reliability is demanded or where its failure or malfunction may directly threaten human life or cause risk of bodily injury. Customers are instructed to contact Elpida Memory's sales office before using this product for such applications. [Product usage] Design your application so that the product is used within the ranges and conditions guaranteed by Elpida Memory, Inc., including the maximum ratings, operating supply voltage range, heat radiation characteristics, installation conditions and other related characteristics. Elpida Memory, Inc. bears no responsibility for failure or damage when the product is used beyond the guaranteed ranges and conditions. Even within the guaranteed ranges and conditions, consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so that the equipment incorporating Elpida Memory, Inc. products does not cause bodily injury, fire or other consequential damage due to the operation of the Elpida Memory, Inc. product. [Usage environment] Usage in environments with special characteristics as listed below was not considered in the design. Accordingly, our company assumes no responsibility for loss of a customer or a third party when used in environments with the special characteristics listed below. Example: 1) Usage in liquids, including water, oils, chemicals and organic solvents. 2) Usage in exposure to direct sunlight or the outdoors, or in dusty places. 3) Usage involving exposure to significant amounts of corrosive gas, including sea air, CL 2 , H 2 S, NH 3 , SO 2 , and NO x . 4) Usage in environments with static electricity, or strong electromagnetic waves or radiation. 5) Usage in places where dew forms. 6) Usage in environments with mechanical vibration, impact, or stress. 7) Usage near heating elements, igniters, or flammable items. If you export the products or technology described in this document that are controlled by the Foreign Exchange and Foreign Trade Law of Japan, you must follow the necessary procedures in accordance with the relevant laws and regulations of Japan. Also, if you export products/technology controlled by U.S. export control regulations, or another country's export control laws or regulations, you must follow the necessary procedures in accordance with such laws or regulations. If these products/technology are sold, leased, or transferred to a third party, or a third party is granted license to use these products, that third party must be made aware that they are responsible for compliance with the relevant laws and regulations. M01E1007 Data Sheet E1729E30 (Ver. 3.0) 33