ETC CG2145L

DEVICES
SRC
TWO ELECTRODE SURGE ARRESTERS
CG/CG2 Series
DESCRIPTION
SRC Devices CG/CG2 GDT's are designed for a high degree of surge protection at a low cost. The CG Series
(75-110V) is used for protection of test and communication equipment in which low voltage limits and extremely
low arc voltages are required. The CG2 Series (145V-1000V) is used for protecting equipment for which higher
voltage limits and holdover voltages are necessary. Comgaps function as switches which dissipate a minimum amount of energy and therefore handle currents that far surpass other types of transient voltage protection.
APPLICATIONS
FEATURES
■
■
■
■
■
■
Small size
Rugged ceramic-metal construction
Low capacitance (<1pF)
Non Radioactive 600-1000 V
Available with or without leads
Available in tape-and-reel packaging
■
■
■
■
■
■
■
Communication lines
CATV equipment
Test equipment
Data lines
Power supplies
Instrumentation circuits
Medical electronics
APPROVALS
■ UL Recognized: File Number E111526
■ Meets REA PE-80
RATINGS (@ 25ο C)
Parameter
Min
Typ
Max
Units
DC Breakdown Voltage
60
72
88
116
195
213
255
297
400
510
680
850
75
90
110
145
230
250
300
350
470
600
800
1000
90
108
132
174
265
288
345
403
540
690
920
1150
V
V
V
V
V
V
V
V
V
V
V
V
Insulation Resistance
10
-
-
Ω
-
-
1
pF
-40
-
+125
°C
10
Capacitance
Operational Temperature
(See detailed specifications for more information.)
www.srcdevices.com
1
SRC
DEVICES
TWO ELECTRODE SURGE ARRESTERS
CG/CG2 Series
SPECIFICATIONS
CG75
All characteristics at 25oC
PARAMETER
Device Specifications
DC Breakdown
Impulse Breakdown
Insulation Resistance
Capacitance
Arc Voltage
CONDITIONS
SYMBOL MIN TYP
CG90
CG110
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
500V/s
100V/µs
50V
1MHz
I=5A min
VBD
Vbd
IR
C
VARC
60
-10
10
-
75
10
90
400
1
-
72
-10
10
-
90
10
108
400
1
-
88
-10
10
-
110
10
132
450
1
-
V
V
pF
V
500A (10/1000µs)
20kA (8/20µs)
10x 1sec @ 60Hz
per REA PE-80, 0.2A
-
1000
5
-
55
20
-
1000
5
-
65
20
-
1000
5
-
80
20
-
shots
shots
A
V
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Ω
Life Ratings(1)
Surge Life
Max Current Surge
AC Current
DC Holdover Voltage
CG2145
PARAMETER
CONDITIONS
SYMBOL MIN TYP
CG2230
CG2250
Device Specifications
DC Breakdown
Impulse Breakdown
Insulation Resistance
Capacitance
Arc Voltage
500V/s
100V/µs
100V
1MHz
I=5A min
VBD
Vbd
IR
C
VARC
116
-10
10
-
145
15
174
500
1
-
195
-10
10
-
230
15
265
600
1
-
213
-10
10
-
250
15
288
625
1
-
V
V
pF
V
500A (10/1000µs)
20kA (8/20µs)
10x 1sec @ 60Hz
1
/2 cycle @ 60Hz
per REA PE-80,0.2A
-
1000
5
-
90
20
20
-
1000
5
-
150
20
20
-
1000
5
-
150
20
20
-
shots
shots
A
A pk
V
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
300
15
345
700
1
-
297
-10
10
-
350
15
403
750
1
-
400
-10
10
-
470
15
540
850
1
-
pF
V
1000
5
150
20
20
-
1000
5
-
150
20
20
-
1000
5
-
150
20
20
-
shots
shots
A
A pk
V
Ω
Life Ratings(1)
Surge Life
Max Current Surge
AC Current
AC Follow-on Current
DC Holdover Voltage
CG2300
PARAMETER
CONDITIONS
SYMBOL MIN TYP
CG2350
CG2470
Device Specifications
DC Breakdown
Impulse Breakdown
Insulation Resistance
Capacitance
Arc Voltage
500V/s
100V/µs
100V
1MHz
I=5A min
VBD
Vbd
IR
C
VARC
500A (10/1000µs)
20kA (8/20µs)
10x 1sec @ 60Hz
1
/2 cycle @ 60Hz
per REA PE-80, 0.2A
-
255
-10
10
-
V
V
Ω
Life Ratings(1)
Surge Life
Max Current Surge
AC Current
AC Follow-on Current
DC Holdover Voltage
CG2600
PARAMETER
CONDITIONS
SYMBOL MIN TYP
CG2800
CG21000
MAX
MIN
TYP
MAX
MIN
TYP
MAX UNITS
690
1000
1
-
680
-10
10
-
800
15
920
1200
1
-
850
-10
10
-
1000 1150
1500
1
15
-
20
20
-
1000
10
-
150
20
20
-
1000
10
-
150
Device Specifications
DC Breakdown
Impulse Breakdown
Insulation Resistance
Capacitance
Arc Voltage
500V/s
100V/µs
100V
1MHz
I=5A min
VBD
Vbd
IR
C
VARC
500A (10/1000µs)
10kA (8/20µs)
10x 1sec @ 60Hz
1
/2 cycle @ 60Hz
per REA PE-80, 0.2A
-
510
-10
10
-
600
15
V
V
Ω
pF
V
Life Ratings(1)
Surge Life
Max Current Surge
AC Current
AC Follow-on Current
DC Holdover Voltage
1000
10
150
(1)End-of-Life limits are: DC: 50% of minimum initial DC breakdown voltage limit to 150% of maximum initial DC breakdown voltage limit
Impulse: less than 150% of initial Impulse breakdown voltage limit.
USA 1-866-SRC-8668 Europe 32-89-328850
www.srcdevices.com
20
20
-
shots
shots
A
A pk
V
Far East 886-2-2698-8422
2
SRC
TWO ELECTRODE SURGE ARRESTERS
CG/CG2 Series
DEVICES
PERFORMANCE CHARACTERISTICCS
CG/CG2 Series
Voltage Breakdown
CG
Follow-On Current
Impulse Discharge Current
4.0
3.6
3.2
2.8
2.4
2.0
1.6
1.2
0.8
0.4
Ramp speeds from
100V/s to 30kV/µs
CG2-1000
CG2-800
CG2-600
CG2-470
CG2-350
CG2-230
CG2-145
CG2-90
10
-8
Current (A)
Breakdown Voltage, Typ. (kV)
30k 10k 5k 1k 500 100 10 3 V/µs 10kV/s 1kV/s 100V/s
Follow Current Only
(Peak Current through gap ≤
Follow Current Rating)
10-7 10-6 10-5 10-4 10-3 10-2 10-1 100 101
8.33
Period of Spark Gap Current (ms)
Time (s)
Transient superimposed
on AC signal (without spark gap)
0
8.33
Line Voltage - With Protection
AC signal and clamped transient
Voltage With Protection
Voltage Without Protection
Line Voltage - No Protection
0
Arc voltage
16.67
8.33
Time (ms)
USA 1-866-SRC-8668 Europe 32-89-328850
www.srcdevices.com
COMGAP extinguished
at First Zero Crossing
16.67
Time (ms)
Far East 886-2-2698-8422
3
SRC
DEVICES
TWO ELECTRODE SURGE ARRESTERS
CG/CG2 Series
MECHANICAL DIMENSIONS
DIMENSIONS
mm
(inches)
Other lead forms are available upon request.
Contact REMtech for more information.
LS Outline
38.10 REF.
(1.500)
0.239±0.012
(6.07±0.30)
0.319 DIA MAX.
(8.10 MAX.)
±
±
0.81 DIA. TYP.
(0.032)
0.331±0.012
(8.40±0.30)
4.09 DIA. 8.10 DIA. MAX.
(0.161)
(0.319)
6.07 ± 0.15
(0.239 ± 0.006)
0.032
(0.81)
0.0157±0.0012
(0.40±0.03)
0.004
0.331±0.012
(8.4±0.3)
2 Surfaces
0.388±0.012
(9.85±0.30)
0.439 ±0.012
(11.15±0.30)
LS Tape & Reel Packaging
LS Recommended Land Pattern
(0.388)
2.00
1.75
(0.341)
4.00
(0.070)
(0.460)
11.50
24.00
16.00
Tape & Reel packaging is available on request. See ordering information below for
part number structure.
ORDERING INFORMATION
CG/CG2’s with other breakdown voltages in the 75-1000 V range
are available upon request. A complete part number is represented
by the digits below. For example, CG75 is a non-leaded 75V device,
CG2-230L is a leaded 230V device, and CG2-800LTR is a leaded
800V device on tape-and-reel per EIA standard RS-296-D.
CG XXX X XX
CG2 XXX X XX
Tape & Reel Information
Series
CGXXXLTR - Tape & Reel per EIA RS-296-D. Quantity =
1,000/Reel
CGXXXLTE - Tape & Reel per IEC286-1.
Quantity = 1,000/Reel
CGXXXLSTR - See figure above for tape & reel information.
Quantity = 1,400/Reel
USA 1-866-SRC-8668 Europe 32-89-328850
www.srcdevices.com
CG
CG2
for 75, 90, 110V
for 145V & up
Shipping Package
TR = Tape & Reel
(Blank) = Bulk
Breakdown Voltage
75 = 75V
90 = 90V
110 = 110V
145 = 145V
230 = 230V
250 = 250V
300 = 300V
350 = 350V
470 = 470V
600 = 600V
800 = 800V
1000 = 1000V
Options
L = Leads
(Blank) = No Leads
Far East 886-2-2698-8422