ETC F3099AA06

F3099 RFI Filters
Maximum Voltage: 250VAC Maximum - 50/60 Hz
Rated Current:
250VAC
6A
Current Overload: 6X for 8 seconds
Hi-Pot Test (1 min):
Line to Ground
1500VAC
Line to Line
1450VDC
Insulation Resistance: 9 x 109 Ω at 100VDC
Ambient Temperature: 40°C Max at rated current
Humidity Range: 0% to 95% R.H.
Termination:
A: Quick Connect
B: Wire
Maximum Leakage Current:
Each Line to Ground F3000 Series
115VAC, 60Hz:
2 μA
250VAC, 50Hz:
5 μA
Agency Approvals:
Features:
• Designed to Meet UL544 and IEC601 Specifications
for Medical and Dental Equipment, both patient care
and onpatient categories.
• Leakage current in this series is extremely low to
satisfy the stringest leakage current limit imposed by
safety regulations for medical and dental equipment.
F3099 Series
Simplified Schematic
F3099AA (6Amp) Dimensions
6A
A
B
C
D
E
2.53
(64,30)
1.82
(46,2)
0.78
(19,8)
2.126
(54,0)
2.53
(64,30)
2.53
(64,30)
1.82
(46,2)
0.78
(19,8)
2.126
(54,0)
1.32
(33,5)
L
L
LOAD
Amps
LINE
General Purpose Filtered Modules
Specifications:
G
N
N
6.36(0.25) FASTON TERMINAL
WITH Ø1.78 (0.070) HOLE
(SLOTTED HOLE
FOR GROUND)
WIRE LEADS, 18AWG,
(16AWG FOR 10A).
102(4.0) MIN.
MEDICAL FILTERS
BLUE
BLUE
G/Y
A D
A D
B
BROWN
B
BROWN
E
E
Nominal
Current
Rating
6A
C
C
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
Part
Number
F3099AA06
F3099BB06
Termination
Line/Load
QC/QC
ø
MODE
Common
Differential
0.05
0.10
.15
3
3
7
6
11
14
Frequency - MHz
.50
1.0
20
20
22
30
5.0
10
30
24
35
22
35
18
35
NOTE: Other combinations of terminals may be specified on special order.
72
www.curtisind.com
Curtis Industries
A Division of Powers Holdings, Inc.
Specifications subject to change.
Dimensions are shown for
reference purposes only.