F3099 RFI Filters Maximum Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 250VAC 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: A: Quick Connect B: Wire Maximum Leakage Current: Each Line to Ground F3000 Series 115VAC, 60Hz: 2 μA 250VAC, 50Hz: 5 μA Agency Approvals: Features: • Designed to Meet UL544 and IEC601 Specifications for Medical and Dental Equipment, both patient care and onpatient categories. • Leakage current in this series is extremely low to satisfy the stringest leakage current limit imposed by safety regulations for medical and dental equipment. F3099 Series Simplified Schematic F3099AA (6Amp) Dimensions 6A A B C D E 2.53 (64,30) 1.82 (46,2) 0.78 (19,8) 2.126 (54,0) 2.53 (64,30) 2.53 (64,30) 1.82 (46,2) 0.78 (19,8) 2.126 (54,0) 1.32 (33,5) L L LOAD Amps LINE General Purpose Filtered Modules Specifications: G N N 6.36(0.25) FASTON TERMINAL WITH Ø1.78 (0.070) HOLE (SLOTTED HOLE FOR GROUND) WIRE LEADS, 18AWG, (16AWG FOR 10A). 102(4.0) MIN. MEDICAL FILTERS BLUE BLUE G/Y A D A D B BROWN B BROWN E E Nominal Current Rating 6A C C MINIMUM INSERTION LOSS - dB (50 ohm Circuit) Part Number F3099AA06 F3099BB06 Termination Line/Load QC/QC ø MODE Common Differential 0.05 0.10 .15 3 3 7 6 11 14 Frequency - MHz .50 1.0 20 20 22 30 5.0 10 30 24 35 22 35 18 35 NOTE: Other combinations of terminals may be specified on special order. 72 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only.