FCI BAT54S

Mechanical Dimensions
BAT54
Description
Single
Common Cathode
Common Anode
Series
Dimensions in mm
SOT-23
Feature
* Low Turn-On Voltage
* Fast Switching, Marking: Single,Series,Common Cathode, Anode--BAT54,54S,54C, 54A
* Ultra Small Surface mount Package
* PN Junction Gard Ring for Transient and ESD protection
* Weight: 0.008gram
Max Ratings at Ta=25C Unless Otherwise Specified
Characteristic
Symbol BAT54 BAT54A BAT54C BAT54S Unit
Peak Repetitive Reverse Voltage
Vrrm
30
30
30
30
V
working Peak Reverse Voltage
Vrwm
30
30
30
30
V
DC Blocking Voltage
Vdc
30
30
30
30
V
RMS Reverse Voltage
Vr(rms)
21
21
21
21
V
Power Dissipation
Pd
200
200
200
200
mW
Forward Continuous Current
If
200
200
200
200
mA
Repetitive Peak Forward Surge Current
Ifrm
300
Peak Forward Surge Current @t=1.0s
Ifsm
600
Operating & torage Temp. Range
mA
600
600
600
mA
Tj/Ts
-55~+125
C
Max Forward Voltage
Vf
240 @ 0.1mA, 400 @ 10mA,
0.32 @ 1mA, 500 @ 30mA,
1000 @100mA
mV
Reverse Leakage Current
Typical Junction Capacitance Vr=1.0V,
f=1.0MHz
Thermal Resistance Junction to Ambient Air
Ir
2
uA
Cj
10
pF
Rthja
500
C/W
1000
1000
O
T A =125 O C
100
REVERSE CURRENT, u A
FORWARD CURRENT, mA
T A =85 C
10
O
T A =125 C
1.0
100
O
T A =85 C
10
1.0
O
T A =25 C
O
T A =25 C
0.1
0.1
0
0.4
1.2
0.8
0
10
20
30
REVERSE VOLTAGE, Volts
FORWARD VOLTAGE, Volts
FIG. 1-TYPICAL FORWARD CHARACTERISTIC
FIG. 2-TYPICAL REVERSE CHARACTERISTICS
400
AVERAGE FORWARD CURRENT, mA
JUNCTION CAPACITANCE, pF
15
10
5
0
0
10
20
30
REVERSE VOLTAGE, Volts
FIG. 3 TYPICAL JUNCTION CAPACITANCE
300
200
100
0
50
100
150
AMBIENT TEMPERATURE( OC)
FIG. 4 FORWARD CURRENT DERATING
200