GENERAL C3603A

Product Data Sheet
Part Number: C3603A
Revision Level:
3C 20 26/34 TC RUBBER RUBBER
A. CONSTRUCTION
Conductor:
Insulation:
Cable:
Jacket:
#20 AWG 26/34 Tinned Copper
0.020" Wall Rubber
3 conductors @ 2.00" LHL with mylar wrap.
0.035" Wall Rubber
marker thread under jacket
1
Date:
MULTI-CONDUCTOR, RUBBER
DIAMETERS
0.037" nom.
0.080" nom.
0.180" nom.
0.255" +/- 0.013"
B. INDUSTRY APPROVALS
NONE
C. ELECTRICAL PROPERTIES
TEMPERATURE:
SUGGESTED WORKING VOLTAGE (Vrms):
CONDUCTOR D.C. RESISTANCE:
D. COLOR CODE
1
2
3
60 C
Vrms
11.3 Ohms/1000 ft nom
(Listed as Individual Conductors or Pairs of Conductors)
Black
White
Red
Note: Data are subject to change without notice. Contact your Customer Service representative for latest information.