Agilent U8000 Series Single Output DC Power Supplies Data Sheet Key Features Excellent load and line regulation: (CV: <0.01% +2 mV; CC: <0.02% + 2mA) Low output noise: 1 mVrms (20 Hz to 20 MHz) Over Voltage and Over Current Protection LCD display with backlight capability Standby output for safety purposes Save-and-recall function up to three memory states Security features: keypad lock and physical lock mechanism Figure 1. The U8001A 90 W and U8002A 150 W single output DC power supplies More Protection, More Convenience — For Less It’s often difficult to find a power supply that is just right for your test requirements and your budget. Whether you’re manufacturing consumer products, testing electronic components, or simply looking for reliable, affordable power, Agilent’s family of basic power supplies now includes single output, non-programmable models in the 90 W to 150 W power range. With capabilities typically found only in programmable supplies, you get excellent value along with great efficiency in your work. As a result, you can minimize setup time and measurement errors and maximize device reliability. You’ll get the right power with a difference — backed by stringent safety certifications and Agilent quality standards — at an affordable price. The Agilent U8000 Series offers 90 W to 150 W single output, non-programmable DC power supplies that include features typically found only in costly programmable supplies. The U8000 Series delivers excellent value by providing reliable DC power, efficient setup capabilities, and important security features that let you address a variety of applications in electronics manufacturing and educational settings. Power That’s Suitable for Your Application Requirements The U8000 Series with power ranging from 90 W to 150 W provides performance that is suitable for electronics manufacturing for computers and peripherals, communication systems and peripherals, aircraft/avionics systems, electronic components, and more. The U8000 Series complements the Agilent E3600 DC power supplies family to provide a wider range of power source alternatives. 2 Work Efficiently with Great Features and Solid Performance — Within Budget Differentiated features typically found only in programmable power supplies The U8000 Series offers fully integrated over voltage protection (OVP) and over current protection (OCP) to prevent damage to the device-under-test (DUT). Using the capability to save and recall three memory states, you can minimize errors and reduce set-up time. The U8000 Series also provides security features such as keypad lock to prevent measurement errors due to accidental front panel usage. When the keypad lock is activated, the knob and all the buttons on the front panel are disabled except the keypad lock button. The physical lock mechanism found at the rear panel of the power supply provides secure instrument storage. The LCD display with backlight on/off options enables brighter display for data viewing (see Figure 2). Get That Something Extra: Safety and Security The U8000 Series has been stringently tested according to various industrial safety standards: CSA (for US and CA regulatory requirements), C-tick (Australia), and CE (Europe). The U8000 Series is fully integrated with OVP and OCP in order to prevent damage to the DUT. The security features offered in the U8000 Series prevent measurement errors and also ensure safety storage of the power supply. Security features such as keypad locking capability preclude accidental front panel usage while the physical lock mechanism provides secure instrument storage. Front Panel Operation An easy-to-use rotary knob and self-guiding keypads allow you to set the output at your desired resolution without any effort. Also, both voltage and current levels can be set to a maximum resolution of 10 mV/10 mA from the front panel. In addition, you can save and recall for up to three operating states that are stored in the internal non-volatile memory. Easy-to-use control functions: • Enabling or disabling OVP and OCP • Setting the OVP and OCP trip levels • Clearing OVP and OCP conditions • Setting and displaying the voltage and current limit values • Operating state storage/recall • Resetting the power supply to power-on state • Calibrating the power supply • Enabling or disabling the output Backlight ON Backlight OFF Solid, reliable performance in its class The U8000 Series provides excellent load and line regulation (Constant Voltage, CV: < 0.01% +2 mV; Constant Current, CC: < 0.02% +2 mA) to ensure stable output even when the load changes. With the fast 50 µsec transient response, test times and manufacturing cost are significantly reduced. The U8000 Series comes with low output noise of 1 mVrms, 3 mArms from 20 Hz to 20 MHz, providing clean output and minimizing the interference in the DUT. Figure 2. Backlight on/off options for LCD display Physical lock mechanism Compliant to several safety standards—CSA, C-tick, CE Figure 3. Safety and security features of the U8000 Series single output DC power supplies 3 Features of the U8000 Series Fully integrated over voltage and over current protection to prevent damages to the DUT Three storage locations (M1, M2, and M3) for user-defined operating states with save-and-recall capability Setting and display of the voltage and current limit values Rotary knob for quick and analog-like control of voltage and current Highly visible LCD displaying actual values of output voltage and current in meter mode and limit values of voltage and current in limit mode Versatile binding posts offer flexibility to use safety test leads, banana plugs or stripped wires Backlight On/Off options enabling brighter data display Control for enabling and disabling the output of the power supply Keypad Lock/Unlock options to prevent accidental front panel usage Selects the knob control function for voltage and current adjustment 4 Performance Specifications Electrical Specifications Parameter Output Ratings (at 0 °C to 40 °C) U8001A U8002A 0 to +30 V 0 to 3 A 0 to +30 V 0 to 5 A Line and Load Regulation CV: <0.01% +2 mV CC: <0.02% +2 mA Ripple and Noise (25 °C ±5 °C) CV: 12 mVp-p, <1 mVrms; CC: 3 mArms Load Transient Response Time (within 15 mV from full load to half load and from half load to full load) <50 μs Programming Accuracy1 (25 °C ±5 °C) <0.35% +20 mV <0.35% +20 mA Readback Accuracy1 (25 °C ±5 ° C) <0.35% +20 mV <0.35% +20 mA Meter Resolution Voltage: 10 mV Current: 10 mA Maximum Output Float Voltage 1 ±240 Vdc Specifications are based on one hour warm-up period. 5 Supplemental Characteristics Supplemental Characteristics Parameter U8001A Temperature Coefficient (for 12 months) U8002A CV: <100 ppm/ °C CC: <380 ppm/ °C Output Voltage Overshoot (during turn-on or turn-off of AC power state with the output control set to less than 1 V) CC: <300 ppm/ °C <1 V Voltage Programming Speed, to within 1% of total excursion Up Full Load No Load 150 ms 100 ms Down Full Load No Load 30 ms 450 ms Last Memory Setting Enabled Yes Over Voltage Protection Response Time <1.5 ms when the trip voltage is equal to or greater than 3 V and <10 ms when the trip voltage is less than 3 V (average time for output to drop from 90% of output voltage to 1 V after OVP condition occurred) Protection Features Parameter U8001A U8002A Over Voltage Protection Accuracy ± (% of output + offset) <0.5% +0.5 V Over Voltage Protection Programmable Range 1 V to 33 V Over Current Protection Accuracy ± (% of output + offset) Over Current Protection Programmable Range <0.5% +0.5 A 1 A to 3.3 A 1 A to 5.5 A U8001A U8002A AC Power Input Specifications Parameter Input Power Option (selectable) 100 Vac ± 10%, 47 to 63 Hz 115 Vac ± 10%, 47 to 63 Hz 230 Vac ± 10%, 47 to 63 Hz Fuse External, customer assessable Physical Specifications Parameter U8001A Dimensions (H x W x L) Weight U8002A 88.1 mm x 212.3 mm x 394.3 mm 7.3 kg 6 8.3 kg General Characteristics Display Calibration Cycle Other Options Liquid Crystal Display (LCD) One year Operating Environment Warm-up time • Option U800xA-AUT Custom Power On • E3600A-100 Test lead kit • Option 1CM Rack-mount kit • Operating temperature from 0 °C to 40 °C (for full rated output) and 40 °C to 55 °C (for derated output) • Relative humidity up to 95% • Altitude up to 2000 meters 60 minutes Storage Compliance -20 °C to 70 °C Safety and EMC Compliance Certified with: • IEC 61326:2002/EN61326:1997+ A1:1998+A3:2003 • CISPR 11:1990/EN55011:1990 • Canada: ICES-001:2004 • Australia/New Zealand: AS/NZS CISPR11:2004 • IEC 61010-1:2001/EN61010-1:2001 (2nd Edition) • Canada: CAN/CSA-C22.2 No. 61010-1-04 • USA: ANSI/UL 61010-1:2004 Rack-mount Kits Ordering Information U8001A DC Power Supply, 30 V, 3 A U8002A DC Power Supply, 30 V, 5 A Included Documentation: U8001A-0B0 No documentation package Additional Documentation: • U8001A-AB0 Traditional Chinese User’s and Service Guide • U8001A-AB2 China – Simplified Chinese printed User’s and Service Guide • U8001A-ABA English User’s and Service Guide • U8001A-ACF Japanese User’s and Service Guide Memory Operations Calibration Document: Up to three operating states U8001A-UK6 Commercial calibration with test result data Programming Language • Standard Commands for • Programmable Instruments (SCPI) Warranty Power Options Opt 0E9 90 to 110 Vac, 47 to 63 Hz Opt 0EM 104 to 126 Vac, 47 to 63 Hz Opt 0E3 207 to 253 Vac, 47 to 63 Hz • One year for U8000 series power supplies • Three months for standard shipped accessories 7 To rack-mount a single instrument: Adapter kit (P/N 5063-9240) To rack-mount two instruments side-byside: Lock-link kit (P/N 5061-9694) Flange kit (P/N 5063-9212) To rack-mount two instruments in a sliding support shelf: Support shelf (P/N 5063-9255) Slide kit (P/N 1494-0015) www.agilent.com Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of systemready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to www.agilent.com/find/removealldoubt Product specifications and descriptions in this document subject to change without notice. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Phone or Fax Americas Canada Latin America United States (877) 894-4414 305 269 7500 (800) 829-4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe & Middle East Austria Belgium Denmark Finland France 01 36027 71571 32 (0) 2 404 93 40 45 70 13 15 15 358 (0) 10 855 2100 0825 010 700* *0.125 /minute 07031 464 6333 Germany 1890 924 204 Ireland 972-3-9288-504/544 Israel 39 02 92 60 8484 Italy 31 (0) 20 547 2111 Netherlands 34 (91) 631 3300 Spain 0200-88 22 55 Sweden 0800 80 53 53 Switzerland 44 (0) 118 9276201 United Kingdom Other European Countries: www.agilent.com/find/contactus Revised: October 6, 2008 © Agilent Technologies, Inc. 2009 Printed in USA, June 16, 2009 5989-7182EN