CLG-60 60W Single Output LED Power Supply series Features : Universal AC input / Full range (up to 295VAC) Built-in active PFC function High efficiency 89% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Pass LPS 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications (Note.2) Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 3 years warranty F 110 M M LPS SELV ( for 48V only) ( except for 48V ) IP67 ( for 20~27V only) SPECIFICATION MODEL DC VOLTAGE CLG-60-12 CLG-60-15 CLG-60-20 CLG-60-24 CLG-60-27 CLG-60-36 CLG-60-48 12V 15V 20V 24V 27V 36V 48V 10.5 ~ 15V 14 ~ 20V 16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V 33.6 ~ 48V 4A 3A 2.5A 2.3A 1.7A 1.3A CONSTANT CURRENT REGION Note.5 8.4 ~ 12V RATED CURRENT 5A CURRENT RANGE 0 ~ 5A 0 ~ 4A 0 ~ 3A 0 ~ 2.5A 0 ~ 2.3A 0 ~ 1.7A 0 ~ 1.3A RATED POWER 60W 60W 60W 60W 62.1W 61W 62.5W RIPPLE & NOISE (max.) Note.2 2Vp-p OUTPUT 11.5 ~ 13V VOLTAGE ADJ. RANGE 10% LINE REGULATION 3.0% 2.7Vp-p 3.6Vp-p 4.6Vp-p 25 ~ 30V 32.5 ~ 39V 43.6 ~ 51.8V 5.0% 3000ms / 230VAC 5000ms / 115VAC at full load SETUP TIME Note.4 90 ~ 295VAC 127 ~ 417VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.94/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve) EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT(max.) 0.8A/115VAC 40A/230VAC LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION 2.7Vp-p 24 ~ 26V Fixed. Can be modified between 3% ~ -25% rated output current VOLTAGE TOLERANCE Note.3 LOAD REGULATION INPUT 1.8Vp-p 19.5 ~ 22V Fixed can be modified between the range above CURRENT ADJ. RANGE VOLTAGE RANGE 2.4Vp-p 14.5 ~ 16.2V OVER VOLTAGE 87.5% 87% 88% 89% 89% <0.75mA / 240VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 13.8 ~ 16V 17.5 ~ 21V 23 ~ 26V 28 ~ 32V 31 ~ 35V 41 ~ 46V 54 ~ 60V Protection type : Shut down o/p voltage, re-power on to recover 12V: 90 OVER TEMPERATURE 86% 0.4A/230VAC 10 15V ~ 48V: 85 (TSW1) detect on heatsink of power transistor 10 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS -30 ~ +70 (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL879, UL8750, UL1310 Class 2, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13(20~27only), IP67 approved SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC EMC ISOLATION RESISTANCE EMC EMISSION I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A 495.7Khrs min. MIL-HDBK-217F (25 ) 195.6*61.5*38.8mm (L*W*H) 0.86Kg; 16pcs/14.8Kg/0.54CUFT MTBF OTHERS DIMENSION PACKING NOTE I/P-FG:1.88KVAC O/P-FG:0.5KVAC 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. File Name:CLG-60-SPEC 2011-07-28 CLG-60 60W Single Output LED Power Supply Mechanical Specification Case No. 957A series Unit:mm 195.6 11.9 171.8 9.6 300 20 300 20 T case SJTW 18AWG 3C +V(Red) -V(Black) 85.9 30.75 61.5 32 46.5 AC/L(Brown) AC/N(Blue) FG (Green/Yellow) SVT 18AWG 2C 4.2 4PL 38.8 T case: Max. Case Temperature. Block Diagram fosc : 90KHz(115VAC) 120KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING FG +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 15 30 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 295 INPUT VOLTAGE (V) 60Hz File Name:CLG-60-SPEC 2011-07-28 CLG-60 60W Single Output LED Power Supply series Power Factor Characteristic PF Constant Current Mode 1 0 0 0 0 0 0 0 0 0 0 0 .0 .9 .9 .9 .9 .9 .8 .8 .8 .8 .8 .7 0 8 6 4 2 0 8 6 4 2 0 8 277V ac 230V ac 115V ac 50% 60% 70% 80% 90% 100% (60W) LOAD EFFICIENCY vs LOAD (48V Model) EFFICIENCY (%) CLG-60 series possess superior working efficiency that up to 89% can be reached in field applications. 92 88 84 80 76 72 68 64 60 56 52 48 44 40 36 277Vac 230Vac 115Vac 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. 100 Vo(%) Constant Current area 70 (max.) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:CLG-60-SPEC 2011-07-28