MEANWELL CLG

CLG-60
60W Single Output LED Power Supply
series
Features :
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
High efficiency 89%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
F
110
M
M
LPS
SELV
( for 48V only)
( except for 48V )
IP67
( for 20~27V only)
SPECIFICATION
MODEL
DC VOLTAGE
CLG-60-12
CLG-60-15
CLG-60-20
CLG-60-24
CLG-60-27
CLG-60-36
CLG-60-48
12V
15V
20V
24V
27V
36V
48V
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
4A
3A
2.5A
2.3A
1.7A
1.3A
CONSTANT CURRENT REGION Note.5 8.4 ~ 12V
RATED CURRENT
5A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.7A
0 ~ 1.3A
RATED POWER
60W
60W
60W
60W
62.1W
61W
62.5W
RIPPLE & NOISE (max.) Note.2 2Vp-p
OUTPUT
11.5 ~ 13V
VOLTAGE ADJ. RANGE
10%
LINE REGULATION
3.0%
2.7Vp-p
3.6Vp-p
4.6Vp-p
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
5.0%
3000ms / 230VAC 5000ms / 115VAC at full load
SETUP TIME
Note.4 90 ~ 295VAC
127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.94/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
85%
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
0.8A/115VAC
40A/230VAC
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
PROTECTION
2.7Vp-p
24 ~ 26V
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3
LOAD REGULATION
INPUT
1.8Vp-p
19.5 ~ 22V
Fixed can be modified between the range above
CURRENT ADJ. RANGE
VOLTAGE RANGE
2.4Vp-p
14.5 ~ 16.2V
OVER VOLTAGE
87.5%
87%
88%
89%
89%
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
13.8 ~ 16V
17.5 ~ 21V
23 ~ 26V
28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
12V: 90
OVER TEMPERATURE
86%
0.4A/230VAC
10
15V ~ 48V: 85
(TSW1) detect on heatsink of power transistor
10
(TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL8750, UL1310 Class 2, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V) ;
J61347-1, J61347-2-13(20~27only), IP67 approved
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
EMC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
495.7Khrs min. MIL-HDBK-217F (25 )
195.6*61.5*38.8mm (L*W*H)
0.86Kg; 16pcs/14.8Kg/0.54CUFT
MTBF
OTHERS
DIMENSION
PACKING
NOTE
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CLG-60-SPEC 2011-07-28
CLG-60
60W Single Output LED Power Supply
Mechanical Specification
Case No. 957A
series
Unit:mm
195.6
11.9
171.8
9.6
300 20
300 20
T case
SJTW 18AWG 3C
+V(Red)
-V(Black)
85.9
30.75
61.5
32
46.5
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
SVT 18AWG 2C
4.2 4PL
38.8
T case: Max. Case Temperature.
Block Diagram
fosc : 90KHz(115VAC)
120KHz(230VAC)
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
+V
-V
DETECTION
CIRCUIT
O.L.P.
PWM & PFC
CONTROL
O.C.P.
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
295
INPUT VOLTAGE (V) 60Hz
File Name:CLG-60-SPEC 2011-07-28
CLG-60
60W Single Output LED Power Supply
series
Power Factor Characteristic
PF
Constant Current Mode
1
0
0
0
0
0
0
0
0
0
0
0
.0
.9
.9
.9
.9
.9
.8
.8
.8
.8
.8
.7
0
8
6
4
2
0
8
6
4
2
0
8
277V ac
230V ac
115V ac
50%
60%
70%
80%
90%
100%
(60W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
CLG-60 series possess superior working efficiency that up to 89% can be reached in field applications.
92
88
84
80
76
72
68
64
60
56
52
48
44
40
36
277Vac
230Vac
115Vac
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
100
Vo(%)
Constant
Current area
70
(max.)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:CLG-60-SPEC 2011-07-28