MICRODC G0505XD-1W

H-XD-1W&G-XD-1W Series
1W,FIXED INPUT,6000V ISOLATED&UNREGULATED SINGLE/DUAL OUTPUT DC-DC CONVERTER
PRODUCT PROGRAM
Input
Efficiency
(%,Typ)
Switching
Frequency
(KHz,Typ)
20
70
UL
12
72
UL
84
9
73
UL
15
67
7
74
UL
G0505XD-1W
±5
±100
±10
70
UL
G0509XD-1W
±9
±56
±6
71
UL
G0512XD-1W
±12
±42
±5
72
UL
G0515XD-1W
±15
±33
±4
73
UL
H1205XD-1W
5
200
20
70
UL
H1209XD-1W
9
111
12
71
UL
H1212XD-1W
12
84
9
72
UL
H1215XD-1W
15
67
7
74
UL
G1205XD-1W
±5
±100
±10
70
UL
G1209XD-1W
±9
±56
±6
71
UL
G1212XD-1W
±12
±42
±5
72
UL
G1215XD-1W
±15
±33
±4
75
UL
Max
Min
H0505XD-1W
5
200
H0509XD-1W
9
111
H0512XD-1W
12
H0515XD-1W
Voltage(VDC)
Nominal
FEATURES
◆Small Footprint
◆DIP Package
◆6KVDC Isolation
◆Temperature Range: -40 to+85 ◆No Heat Sink Require
◆No External Component Require
◆Internal SMD Construction
◆Industry Standard Pinout
◆RoHS Compliance
5
12
Item
Isolation voltage
Isolation resistance
MODEL SELECTION
②
③
Range
4.5-5.5
10.8-13.2
Current
* Designing.
ISOLATION
①
Output
Voltage
(VDC)
Order code
④
⑤
SPECIFICATIONS
Test Conditions
Min
Tested for 1 minute and 1mA max
6000
Test at 1000VDC
1000
Isolation capacitance
Typ
Max
Units
VDC
MΩ
3.5
pF
⑥
H 05 05 X D -1W
①Product Series
③Output Voltage
⑤DIP Package
②Input Voltage
④Fixed Input
⑥Rated Power
COMMON SPECIFICATIONS
Item
APPLICATIONS
Test Conditions
Min
Typ
Storage humidity range
The G_XD-1W& H_XD-1W Series are specially
designed for applications where a group of polar power supplies
are isolated from the input power supply in a distributed power
supply system on a circuit board.
These products apply to:
1) Where the voltage of the input power supply is fixed
(voltage variation ≤10%);
2) Where isolation is necessary between input and output
(isolation voltage ≤6000VDC);
3) Where the regulation of the output voltage and the output
ripple noise are not demanded.
Such as: purely digital circuits, ordinary low frequency
analog circuits, and IGBT power device driving circuits.
Max
Units
95
%
Operating temperature
-40
85
Storage temperature
-55
125
Temp. rise at full load
Lead temperature
Short circuit protection*
15
1.5mm from case for 10 seconds
300
5V input voltage
1
12V input voltage
S
Continuous
Cooling
Free air convection
Case material
Plastic(UL94-V0)
MTBF
℃
30
3500
Weight
K hours
8.2
* When input voltage (Nominal) is 5V, Supply voltage must be discontinued at the end of short circuit
MICRODC reserves the copyright
http://www.microdc.cn
duration.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 2
g
H-XD-1W&G-XD-1W Series
Recommended testing and application circuit
OUTPUT SPECIFICATIONS
Item
Test conditions
Min
If
Typ
Max
Units
you want
ends of
Output power
Line regulation
0.1
1
to
further
decrease
the
“ LC ” filtering network may be connected to
the
input/output ripple, an
input
and
output
the DC/DC converter, see (Figure 1).
W
±1.2
For Vin change of 1%
10% to 100% load 5V output
10
15
10% to 100% load 9V output
8.3
15
10% to 100% load 12V output
6.8
15
10% to 100% load 15V output
6.3
15
%
Load regulation
Output voltage accuracy
See tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
Switching frequency
150
Full load
5V input
250
nominal input
12V input
50
0.03
%/℃
200
mVp-p
*Test ripple and noise by "parallel cable"method. See detailed operation instructions at Testing of Power
It should also be noted that the inductance and the
frequency of
the "LC" filtering network should be staggered with
the DC/DC frequency to avoid mutual interference. However,
the capacitance of the output filter
KHz
For every channel
TYPICAL CHARACTERISTICS
be proper.
of output,
provided the safe and reliable
operation is ensured, the greatest capacitance of its filter capacitor sees
(Table 1).
EXTERNAL CAPACITOR TABLE (Table 1)
Converter section, application notes.
Note: Dual output models unbalanced load: ±5%.
%.
capacitor must
If the capacitance is too big, a startup problem might arise.
Single
Dual
Vin
Cin
(VDC)
(uF)
5
4.7
5
10
±5
4.7
12
2.2
9
4.7
±9
2.2
24
1
12
2.2
±12
1
-
-
15
1
±15
1
It not
Cout
Vout
(VDC)
Cout
Vout
(uF)
(VDC)
(uF)
recommend to connect any external capacitor in the
application field with less than 0.5 watt output.
Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output
voltage regulation,
over-voltage and over-current protection is a linear voltage regulator
with overheat protection that is connected to the input or output end in
series (Figure 2).
Dual Output
OUTLINE DIMENSIONS & PIN CONNECTIONS
Overload Protection
Under
normal operating conditions,
these products has
the output circuit of
no protection against overload. The simplest
method is to connect a self-recovery fuse in series at the input
end or add a circuit breaker to the circuit.
No parallel connection or plug and play
Note:
1. All specifications measured at Ta=25, humidity<75%,nominal input
voltage and rated output load unless otherwise specified.
2. Only typical models
please contact our
3. Operation under
listed,
other models may
be different,
technical person for more details.
minimum load will not damage the
converter; However, they may not meet all specification listed.
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646 E-mail:[email protected]
Website:http://www.microdc.cn
Microdc Professional Power module,Inc.makes no representation that
the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or
future patent rights. Specifications are subject to change without notice.
2010 Microdc Professional Power Module, Inc. Guangzhou
http://www.microdc.cn
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave
solder temperature of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped
over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over
Nickel Preplate. Both types in this series are backward compatible with
Sn/Pb soldering systems.
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful
chemicals, it also has harmful chemical substances through the
registration, inspection and approval.