H-XD-1W&G-XD-1W Series 1W,FIXED INPUT,6000V ISOLATED&UNREGULATED SINGLE/DUAL OUTPUT DC-DC CONVERTER PRODUCT PROGRAM Input Efficiency (%,Typ) Switching Frequency (KHz,Typ) 20 70 UL 12 72 UL 84 9 73 UL 15 67 7 74 UL G0505XD-1W ±5 ±100 ±10 70 UL G0509XD-1W ±9 ±56 ±6 71 UL G0512XD-1W ±12 ±42 ±5 72 UL G0515XD-1W ±15 ±33 ±4 73 UL H1205XD-1W 5 200 20 70 UL H1209XD-1W 9 111 12 71 UL H1212XD-1W 12 84 9 72 UL H1215XD-1W 15 67 7 74 UL G1205XD-1W ±5 ±100 ±10 70 UL G1209XD-1W ±9 ±56 ±6 71 UL G1212XD-1W ±12 ±42 ±5 72 UL G1215XD-1W ±15 ±33 ±4 75 UL Max Min H0505XD-1W 5 200 H0509XD-1W 9 111 H0512XD-1W 12 H0515XD-1W Voltage(VDC) Nominal FEATURES ◆Small Footprint ◆DIP Package ◆6KVDC Isolation ◆Temperature Range: -40 to+85 ◆No Heat Sink Require ◆No External Component Require ◆Internal SMD Construction ◆Industry Standard Pinout ◆RoHS Compliance 5 12 Item Isolation voltage Isolation resistance MODEL SELECTION ② ③ Range 4.5-5.5 10.8-13.2 Current * Designing. ISOLATION ① Output Voltage (VDC) Order code ④ ⑤ SPECIFICATIONS Test Conditions Min Tested for 1 minute and 1mA max 6000 Test at 1000VDC 1000 Isolation capacitance Typ Max Units VDC MΩ 3.5 pF ⑥ H 05 05 X D -1W ①Product Series ③Output Voltage ⑤DIP Package ②Input Voltage ④Fixed Input ⑥Rated Power COMMON SPECIFICATIONS Item APPLICATIONS Test Conditions Min Typ Storage humidity range The G_XD-1W& H_XD-1W Series are specially designed for applications where a group of polar power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is fixed (voltage variation ≤10%); 2) Where isolation is necessary between input and output (isolation voltage ≤6000VDC); 3) Where the regulation of the output voltage and the output ripple noise are not demanded. Such as: purely digital circuits, ordinary low frequency analog circuits, and IGBT power device driving circuits. Max Units 95 % Operating temperature -40 85 Storage temperature -55 125 Temp. rise at full load Lead temperature Short circuit protection* 15 1.5mm from case for 10 seconds 300 5V input voltage 1 12V input voltage S Continuous Cooling Free air convection Case material Plastic(UL94-V0) MTBF ℃ 30 3500 Weight K hours 8.2 * When input voltage (Nominal) is 5V, Supply voltage must be discontinued at the end of short circuit MICRODC reserves the copyright http://www.microdc.cn duration. Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 1 of 2 g H-XD-1W&G-XD-1W Series Recommended testing and application circuit OUTPUT SPECIFICATIONS Item Test conditions Min If Typ Max Units you want ends of Output power Line regulation 0.1 1 to further decrease the “ LC ” filtering network may be connected to the input/output ripple, an input and output the DC/DC converter, see (Figure 1). W ±1.2 For Vin change of 1% 10% to 100% load 5V output 10 15 10% to 100% load 9V output 8.3 15 10% to 100% load 12V output 6.8 15 10% to 100% load 15V output 6.3 15 % Load regulation Output voltage accuracy See tolerance envelope graph Temperature drift 100% full load Ripple & Noise* 20MHz Bandwidth Switching frequency 150 Full load 5V input 250 nominal input 12V input 50 0.03 %/℃ 200 mVp-p *Test ripple and noise by "parallel cable"method. See detailed operation instructions at Testing of Power It should also be noted that the inductance and the frequency of the "LC" filtering network should be staggered with the DC/DC frequency to avoid mutual interference. However, the capacitance of the output filter KHz For every channel TYPICAL CHARACTERISTICS be proper. of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1). EXTERNAL CAPACITOR TABLE (Table 1) Converter section, application notes. Note: Dual output models unbalanced load: ±5%. %. capacitor must If the capacitance is too big, a startup problem might arise. Single Dual Vin Cin (VDC) (uF) 5 4.7 5 10 ±5 4.7 12 2.2 9 4.7 ±9 2.2 24 1 12 2.2 ±12 1 - - 15 1 ±15 1 It not Cout Vout (VDC) Cout Vout (uF) (VDC) (uF) recommend to connect any external capacitor in the application field with less than 0.5 watt output. Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure 2). Dual Output OUTLINE DIMENSIONS & PIN CONNECTIONS Overload Protection Under normal operating conditions, these products has the output circuit of no protection against overload. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. No parallel connection or plug and play Note: 1. All specifications measured at Ta=25, humidity<75%,nominal input voltage and rated output load unless otherwise specified. 2. Only typical models please contact our 3. Operation under listed, other models may be different, technical person for more details. minimum load will not damage the converter; However, they may not meet all specification listed. Microdc Professional Power Module,Inc. Tel:0086-20-86000646 E-mail:[email protected] Website:http://www.microdc.cn Microdc Professional Power module,Inc.makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. Specifications are subject to change without notice. 2010 Microdc Professional Power Module, Inc. Guangzhou http://www.microdc.cn RoHS COMPLIANT INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are backward compatible with Sn/Pb soldering systems. REACH COMPLIANT INFORMATION This series has proven that this product does not contain harmful chemicals, it also has harmful chemical substances through the registration, inspection and approval. Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 2 of 2