Hartcran House, 231 Kenton Lane, Harrow, Middlesex, HA3 8RP, England Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233, www.radiometrix.com FPX3 Issue 2, 27 July 2012 High power Multichannel 869MHz band transceiver FPX3 is a small, high power (half-watt) multichannel wide band FM transceiver, operating in the Europe-wide 869.40 - 869.65MHz subband. It is also available in the Indian licence free 865-867MHz band (General telemetry and RFID). Figure 1: FPX3-869-20 Features Conforms to ETSI EN 300 220-3 and EN 301 489-3 Conforms to Indian low power requirements for 865 - 867 MHz band High performance PLL synthesizer +26dBm RF power output Data rates up to 20 kbps for standard module Usable range over 3km Fully screened. Low profile Feature-rich interface (RSSI, analogue and digital baseband) Re-programmable via RS232 interface Applications Asset tracking systems Industrial telemetry and telecommand High performance security system Fire alarms ROV control applications High speed data modems Technical Summary Operating frequency: 868 – 870MHz (EU), 865 - 867MHz (India) Maximum of 8 channels (depends on band allocation and data rate) Transmit power: 400mW (+26dBm) nominal Supply range: +5V regulated Current consumption: 500mA (at 400mW output) transmit, 50mA receive Data bit rate: 20kbps max. (standard module) Receiver sensitivity: -115dBm for 12dB SINAD (20kbps variant) -117dBm for 12dB SINAD (10kbps variant) Size: 67 x 30 x 12mm Evaluation Platform: Narrow Band Evaluation Kit Radiometrix Ltd FPX3 Data Sheet (preliminary) page 1 Figure 2: FPX3 block diagram Radiometrix Ltd FPX3 Data Sheet (preliminary) page 2 Figure 3: FPX3 footprint (Top) view Pin Description Pins RF 1A 2A 3A Normal mode NO PIN RF in/out RF Gnd To the antenna RF ground 4A 5A 6A User 1 2 GND GND Vcc (TX) 0V 0V 7 +5V regulated supply for TX TXD TXE 3 4 5 6 7 8 9 10 11 GND Vcc P3 P2 P1 PGM in RSSI RXD AF out DC coupled input for 5v pp CMOS logic waveforms Transmit enable. Low = TX mode 0V 8 DC supply input (+5V regulated) Parallel channel select Parallel channel select Parallel channel select Serial programming/control input (inverted logic level RS232) DC level between 0.5V and 2.5V. 60dB dynamic range Open collector output of data slicer. 47K pullup to 4V 500mV p-p audio. DC coupled, approx 0.8V bias NOTES: 1. No inversion occurs between TXD and RXD. 2. P1 - P3 (parallel channel selects) and N_TXE are active LOW and have internal 47K pullups to 4v 3. RXD is an open collector output, with a weak pullup to 4v (approx 50K) 4. This radio has no 'internal modem' functions in this version. 5. Programming port (P0) operates at 2400 baud. (Command set specific to this design). The unit is capable of operating in 'basic' parallel channel select only mode, or in serial controlled 'expanded' mode 6. The high current (500mA maximum) transmitter supply (5v regulated) is fed to a separate pin, on the RF out connector. The V supply (pin 4 on the user connector) also requires a 5v regulated supply, and draws up to 50mA Both pins must be supplied at all times (most users connect them to a common +5v supply) 7. 10% duty cycle: While the FPX3 is capable of transmitting continuously (the case temperature will rise noticeably) this will be in contravention of the sub-band restrictions. Units operating in the high power 869.4-869.65MHz sub-band are limited to 10% maximum transmit duty cycle. It is the responsibility of the user to ensure that this restriction is complied with. Alternatively, the user may wish to implement a listen-before-talk protocol (using the RSSI output). See EN300-220 for further details Radiometrix Ltd FPX3 Data Sheet (preliminary) page 3 Serial interface commands Serial data is sent to the unit on the programming input (PGM). To successfully program the unit, it must be powered Unlike earlier Radiometrix multichannel units, the FPX3 has separate N and R registers for each channel, on transmit and on receive. In other words, the frequency of each channel is individually programmed in every mode. Commands include: Commands GOCHAN a SETPAR SETSER <cr> / # Function serial select of channel a (ch0 to 7) channel selected by 3 bit parallel input channel selected by most recent 'gochan' operation process entry clear all buffers disable command mode Most users will not need to edit the table which relates channel frequency, channel number and synthesizer register programming values. The commands below are used to access the eeprom table containing this information. Users should be warned that, in order to get the optimum switching speed from the module, the standard channel setup uses a different reference frequency for each channel, and the absolute calculated channel frequency is allowed to deviate by up to +/-2KHz from the nominal LOAD aa nnnnn (aa = 0 – 7) LOAD aa nnnnn (aa = 8 – 15) LOAD aa rrrrr (aa = 16 – 23) LOAD aa rrrrr (aa = 24 – 31) set value of N for channel a , for receive set value of N for channel a , for transmit set value of R for channel a , for receive set value of R for channel a , for transmit Reference frequency (10MHz/R) must be in the range 210 to 300KHz (tx) or 175 to 300KHz (rx). As a rule of thumb, an R value greater than 45 (tx) or 55 (rx) should be viewed with suspicion. a = single digit channel number from 0 to 7 aa = eprom location number from 0 to 31 nnnnn = a synthesizer N register value, (up to 65535) rrrrr = the synthesizer R register value, (up to 16383) ALL COMMANDS MUST BE IN UPPER CASE. Notice that the synthesizer and VCO operate at half the output frequency, so for a frequency of 869.475MHz, the actual N/R values will be set for 434.7375MHz Further information TBA NOTE: A pause of at least 50mS must be allowed between command strings (eeprom programming time) Radiometrix Ltd FPX3 Data Sheet (preliminary) page 4 Condensed specifications (All details are provisional) Frequency Frequency stability Channel spacing Number of channels Supply Receive Transmit: Operating temperature Spurious radiations 868 – 870MHz (EU), 865 - 867MHz (India) +/-5ppm (better than ±5kHz) 100kHz 8 maximum FPX3-869-20 for EU CH0: 869.475MHz, CH1-CH3: 869.565MHz CH4-CH7=869.50MHz for backward compatibility FPX3-869-10 for EU CH0:869.450MHz, CH1:869.500MHz, CH2:869.550MHz, CH3:869.600MHz, CH4-CH7=869.50MHz for backward compatibility FPX3-866-10 or FPX3-866-20 for India CH0 = 865.143 MHz CH1 = 865.294 MHz CH2 = 865.500 MHz CH3 = 865.789 MHz CH4 = 866.047 MHz CH5 = 866.383 MHz CH6 = 866.531 MHz CH7 = 866.829 MHz 5.0V regulated at 50mA 5.0V regulated at 500mA for 400mW output ο ο -20 to +70 C (Storage -30 to +70 C) Compliant with ETSI EN 300 220-3 and EN 301 489-3 (EU) Interface User RF and TX supply Recommended PCB hole size Size Transmitter Output power TX on switching time Modulation type TX modulation bandwidth Peak FM Deviation Adjacent channel TX power TX spurii Inputs Receiver Sensitivity image / spurious blocking adjacent channel Outputs 11 pin 0.1" pitch molex 5 pin 0.1" pitch molex 1.2mm (min.) 67 x 30 x 12mm 400mW (+26dBm) 5 ms FM, FSK (F1D, F3D) DC – 10kHz ±8kHz nominal (FPX3-xxx-10) ±16kHz nominal (FPX3-xxx-20) -37dBm <-36dBm 5V pk-pk CMOS data -117dBm for 12dB SINAD at 1KHz (FPX3-xxx-10) -115dBm for 12dB SINAD at 1KHz (FPX3-xxx-20) -107dBm for <0.1% data errors (20Kbit/sec NRZ) -55dB -80dB -60dB (Tested per. ETSI 300-220-2.3.1) RSSI, Audio, Data Ordering Information Part No. FPX3-869-10 FPX3-869-20 FPX3-866-10-IND FPX3-866-20-IND Radiometrix Ltd Description 10kbps, 4-channel EU version 20kbps, 2-cannnel EU version 10kbps, 8-channel Indian version 20kbps, 8-channel Indian version FPX3 Data Sheet (preliminary) Frequency band (MHz) 869.40 – 869.65 MHz 869.40 – 869.65 MHz 865 – 867 MHz 865 – 867 MHz page 5 FPX3 Data Sheet (preliminary) 10 100 500 868.0 600kHz 25mW <1% or LBT Duty Cycle [mW] No Spacing Non-specific SRD Channel Spacing RF POWER [ERP] Radiometrix Ltd Applications 868.60 100kHz 868.70 10mW <1% 25kHz or WB Alarm 500kHz 25mW <0.1% or LBT No Spacing Non-specific SRD <1% 25kHz 869.25 250kHz 500mW 869.65 869.70 50kHz 25mW <10% or LBT <10% 869.30 869.40 50kHz 50kHz 100kHz 869.20 No Spacing 25kHz 25kHz or Wide Band 300kHz 5mW 870.0 up to 100% Non-specific SRD Alarm Non-specific SRD 10mW 10mW 10mW <0.1% 25kHz Social Alarm Alarm CEPT/ERC Rec 70-03, 868 MHz Band Plan [MHz] Appendix page 6 Radiometrix Ltd Hartcran House 231 Kenton Lane Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 [email protected] www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000 R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)300 123 3333 or 020 7981 3040 Fax: +44 (0)20 7981 3333 [email protected] European Communications Office (ECO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 [email protected] www.ero.dk