Class 2 UL5085 - 3 Transformer 60VA - 75VA, Non-Inherently Energy Limited Series: CL - Lead Wires & Quick-Connects Power Rating 60VA to 75VA Secondary Fusing Required (Provided by Factory), Frequency 50/60Hz Insulation Class B (155°C) Agency Approvals: UL/cUL 5085-3 Class 2 Recognized (File E49606) Insulation File No. E95662 Class 2 * 60 & 75VA transformers must have overcurrent protectors in series with the secondary winding. * Multi voltage combinations are available - consult factory. Lead Wires Quick-Connects Type HX Foot Mount - Steel bracket welded to the bottom of the laminations for easy mounting Type GX Panel Mount - 0.218” (5.54 mm) diameter holes in each corner to allow direct mounting to a panel. Lead Wires: All leads are 18 AWG stranded 2/64” (0.794 mm) insulation thickness. Standard parts have 12” (305 mm) total length with 1/2” (12.7 mm) strip. Type BB Foot Mount, Pri & Sec on Same Side - Quick connect terminals with line and load terminations on the same side of transformer. Type AE Laydown, Pri & Sec on Top Side - Quick connect terminals with line and load terminations on the top of transformer. Type AB Foot Mount, Pri & Sec on Opposite Side - Quick connect terminals with line and load terminations on opposite sides of transformer Terminals: Standard male quick connects - .250” x .032” (6.35 x .81mm). Other available quick connects - .187” x .032” (4.75 x .81 mm) Type HX - Foot Mount, Internally Fused Type BB - Foot Mount, Pri & Sec on Same Side Type HX - Foot Mount, Integral Circuit Breaker Type GX - Panel Mount Type AE - Laydown, Pri & Sec on Top side, Internally Fused Type AE - Laydown Termination, Pri & Sec on Top Side, Integral Circuit Breaker Dimensions (Inches) A B Internally Fused 2.500 1.000 w/ Integral Circuit Breaker 3.300 1.000 Standard Part 2.500 1.000 Any application, Any requirement, Contact us for our Custom Designs 20 Sales Office: 300 W Factory Road, Addison IL 60101 • Phone: (630) 628-9999 • Fax: (630) 628-9922 • www.wabashtransformer.com Class 2 UL5085 - 3 Transformer 60VA - 75VA, Non-Inherently Energy Limited Class 2 Series: CL - Lead Wires & Quick-Connects Partial Selection Guide Primary Voltage Secondary Voltage 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 12 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 24 24Vct 208/230 120 277 120/208/240 480 120/208/240/480 600 277/380/575 380 277/380/415/480 208/240 380/415 575 480/575 200/230 240 120/277 208/240/480 208 100 265 208/230/460 380/460 60 VA Size - 1.0” X 1.0” CL60H00-000* CL60H00-0CT* CL60H01-000* CL60H01-0CT* CL60H02-000* CL60H02-0CT* CL60H03-000* CL60H03-0CT* CL60H04-000* CL60H04-0CT* ─ ─ CL60H06-000* CL60H06-0CT* CL60H08-000* CL60H08-0CT* CL60H09-000* CL60H09-0CT* ─ ─ CL60H15-000* CL60H50-000* CL60H15-0CT* CL60H17-000* CL60H17-0CT* CL60H21-000* CL60H21-0CT* CL60H30-000* CL60H30-0CT* CL60H31-000* CL60H31-0CT* CL60H40-000* CL60H40-0CT* CL60H41-000* CL60H41-0CT* CL60H44-000* CL60H44-0CT* CL60H45-000* CL60H45-0CT* CL60H48-000* CL60H48-0CT* CL60H52-000* CL60H52-0CT* CL60H54-000* CL60H54-0CT* CL60H60-000* CL60H60-0CT* UL √ √ √ √ √ √ √ √ √ √ - √ √ √ √ √ √ - √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ 75 VA Size - 1.0” X 1.0” CL75J00-000* CL75J00-0CT* CL75J01-000* CL75J01-0CT* CL75J02-000* CL75J02-0CT* CL75J03-000* CL75J03-0CT* CL75J04-000* CL75J04-0CT* CL75J05-000* CL75J05-0CT* CL75J06-000* CL75J06-0CT* CL75J08-000* CL75J08-0CT* CL75J09-000* CL75J09-0CT* CL75J14-000* CL75J14-0CT* CL75J15-000* ─ CL75J15-0CT* CL75J17-000* CL75J17-0CT* CL75J21-000* CL75J21-0CT* CL75J30-000* CL75J30-0CT* CL75J31-000* CL75J31-0CT* CL75J40-000* CL75J40-0CT* CL75J41-000* CL75J41-0CT* CL75J44-000* CL75J44-0CT* CL75J45-000* CL75J45-0CT* CL75J48-000* CL75J48-0CT* CL75J52-000* CL75J52-0CT* CL75J54-000* CL75J54-0CT* CL75J60-000* CL75J60-0CT* UL √ √ √ √ √ √ √ √ √ √ √ √ - √ √ - √ √ √ - √ - √ √ - √ √ √ √ √ √ - √ √ √ √ √ √ - * Refer to page number 7. Must complete part number to specify voltages, termination, mounting & fusing. For custom designs 3 digit customer ID will be added at the end of the part number. Lead Wire Details: Primary Voltage Color Secondary Voltage Color COM Black COM Blue 110,115,120 White 12 Yellow 200,208,215 Red 24 Blue 220, 230, 240 Orange 265, 277 Brown 380 Violet 400, 415 Red/White 460, 480 Grey 575 Black/Red 600 Black/White Standard leads: All leads are 12.0” L.O.C (length out of coil) 1/2” strip Any application, Any requirement, Contact us for our Custom Designs Sales Office: 300 W Factory Road, Addison IL 60101 • Phone: (630) 628-9999 • Fax: (630) 628-9922 • www.wabashtransformer.com 21