Datasheet System LXXX LXXX 15.00/03/90 4.5SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com The high-current PCB connection for more power on board: 150 A /1000 V with wires up to 50 mm², transmitted right to the PCB! The LXXX 15.0 – with its proven steel clamping-yoke technology in a compact standard housing – integrates the latest market requirements for security, power density and miniaturization in power electronics. It connects these requirements into an efficient solution for the entire value-creation chain – including development, production, installation and maintenance. The function and form of the application's connection method plays a key role. It influences the application's design, reliability, usability and costs. With the Substitution of For example, with the replacement of complex constructions involving bolts or bus bars, the PCB can be transformed into a system platform that is both consistent and sustainable into the future – even for high-current applications. The LXXX 15.0 reduces size and complexity while at the same time improving application integration. In so doing, it fulfils the requirements of power electronics better than the established mechanisms and connection elements. General ordering data Material number 1047140000 Short text for material LXXX 15.00/03/90 4.5SN BK BX Article - short description PCB terminal, Clamping yoke connection, Solder connection, Clamping range, rated connection, max.: 50 mm², Pitch in mm: 15.00 mm, No. of poles: 3, 90°, Box EAN 4032248784011 Qty. 10 pc(s). Packaging Box Creation date February 19, 2011 12:03:37 AM CET Last update 29.11.2010 / We reserve the right to make technical changes. 1 Datasheet System LXXX LXXX 15.00/03/90 4.5SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com Technical data Approvals Approvals CSA; UR System parameters Product family Fitted to PCB Pitch in mm No. of poles No. of rows Diameter of solder eyelet Number of solder pins per pole Screwdriver blade standard Tightening torque, max. Stripping length L1 in inch System LXXX Solder connection 15 mm 3 1 Conductor connection system Outgoing direction of conductor Pitch in inch Fitted by customer Solder pin length Tolerance of the diameter of the solder eyelet Screwdriver blade Tightening torque, min. Clamping screw L1 in mm Clamping yoke connection 90° 0.591 inch No 4.5 mm Wemid (PA) V-0 Copper alloy Copper alloy Colour CTI Contact surface black ≥ 600 tinned 0.5 mm² Clamping range, rated connection, max. Conductor connection cross-section AWG, max. Solid, max. H05(07) V-U Stranded, min. H07V-R Flexible, max. H05(07) V-K with wire end ferrule, DIN 46228 pt 1, max. with plastic collar ferrule, DIN 46228 pt 4, max. 50 mm² 150 A 8 kV Rated current, no. of poles (Tu=40°C), min. Rated voltage for overvoltage class/pollution severity III/2 Rated impulse withstand voltage for overvoltage class/pollution severity II/2 Rated impulse withstand voltage for overvoltage class/pollution severity III/3 600 V 600 V 600 V AWG 20 Rated current (use group B) Rated current (use group C) Rated current (use group D) Wire cross-section, AWG, max. 127 A 127 A 5A AWG 1 1.6 mm 4 DIN 5264 4 Nm 18 mm 1.181 inch + 0,1 mm 1.2 x 6.5 2.5 Nm M6 30 mm Material data Insulating material Flammability class UL 94 Contact material Contact base material Connectable conductors Clamping range, rated connection, min. Conductor connection cross-section AWG, min. Solid, min. H05(07) V-U Stranded, max. H07V-R Flexible, min. H05(07) V-K w. wire end ferrule, DIN 46228 pt 1, min w. plastic collar ferrule, DIN 46228 pt 4, min. AWG 20 0.5 mm² 50 mm² 0.5 mm² 0.5 mm² 0.5 mm² AWG 1 16 mm² 6 mm² 35 mm² 35 mm² 35 mm² DIN IEC rating data Rated current, min. No. of poles (Tu=20°C) Rated voltage for overvoltage class/pollution severity II/2 Rated voltage at overvoltage category/ pollution degree III/3 Rated impulse withstand voltage for overvoltage class/pollution severity III/2 150 A 1,000 V 1,000 V 1,000 V 8 kV 8 kV CSA rating data Rated voltage (Use group B) Rated voltage (Use group C) Rated voltage (use group D) Wire cross-section, AWG, min. Creation date February 19, 2011 12:03:37 AM CET Last update 29.11.2010 / We reserve the right to make technical changes. 2 Datasheet System LXXX LXXX 15.00/03/90 4.5SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com Technical data UL 1059 rating data Rated voltage (use group B) Rated voltage (use group C) Rated voltage (use group D) Wire cross-section, AWG, min. 600 V 600 V 600 V AWG 20 Rated current (use group B) Rated current (use group C) Rated current (use group D) Wire cross-section, AWG, max. 127 A 127 A 5A AWG 1 EC001284 27-26-11-01 ETIM 4.0 EC002643 Classifications ETIM 3.0 eClass 6.0 Notes Notes • Additional colours on request • Rated current related to rated cross-section and min. No. of poles. • Wire end ferrule without plastic collar to DIN 46228 pt 1 • Wire end ferrule with plastic collar to DIN 46228 pt 4 • P on drg. = pitch • Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. • IP 20 from 16 mm² to 50 mm² Creation date February 19, 2011 12:03:37 AM CET Last update 29.11.2010 / We reserve the right to make technical changes. 3 Datasheet System LXXX LXXX 15.00/03/90 4.5SN BK BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com Drawings Derating curve Derating curve Derating curve Creation date February 19, 2011 12:03:37 AM CET Last update 29.11.2010 / We reserve the right to make technical changes. 4