User’s Manual ID850NWC Ver. 2.51 Integrated Debugger Operation Target Device V850 Series™ Document No. U16525EJ1V0UM00 (1st edition) Date Published February 2003 CP(K) © NEC Electronics Corporation 2003 Printed in Japan [MEMO] 2 User’s Manual U16525EJ1V0UM V850 Series, V853, V850/SA1, V850/SB1, V850/SB2, V850/SC1, V850/SC2, V850/SC3, V850/SF1, V850/SV1, V850E/MS1, V850E/MA1, V850E/MA2, V850E/IA1, and V850E/IA2 are trademarks of NEC Electronics Corporation. Windows and WindowsNT are either a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries. PC/AT is a trademark of International Business Machines Corporation. User’s Manual U16525EJ1V0UM 3 These commodities, technology or software, must be exported in accordance with the export administration regulations of the exporting country. Diversion contrary to the law of that country is prohibited. • The information in this document is current as of February, 2003. The information is subject to change without notice. For actual design-in, refer to the latest publications of NEC Electronics data sheets or data books, etc., for the most up-to-date specifications of NEC Electronics products. Not all products and/or types are available in every country. Please check with an NEC Electronics sales representative for availability and additional information. • No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Electronics. NEC Electronics assumes no responsibility for any errors that may appear in this document. • NEC Electronics does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from the use of NEC Electronics products listed in this document or any other liability arising from the use of such products. No license, express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Electronics or others. • Descriptions of circuits, software and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples. The incorporation of these circuits, software and information in the design of a customer's equipment shall be done under the full responsibility of the customer. NEC Electronics assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits, software and information. • While NEC Electronics endeavors to enhance the quality, reliability and safety of NEC Electronics products, customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely. To minimize risks of damage to property or injury (including death) to persons arising from defects in NEC Electronics products, customers must incorporate sufficient safety measures in their design, such as redundancy, fire-containment and anti-failure features. • NEC Electronics products are classified into the following three quality grades: "Standard", "Special" and "Specific". The "Specific" quality grade applies only to NEC Electronics products developed based on a customerdesignated "quality assurance program" for a specific application. The recommended applications of an NEC Electronics product depend on its quality grade, as indicated below. Customers must check the quality grade of each NEC Electronics product before using it in a particular application. "Standard": Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots. "Special": Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support). "Specific": Aircraft, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems and medical equipment for life support, etc. The quality grade of NEC Electronics products is "Standard" unless otherwise expressly specified in NEC Electronics data sheets or data books, etc. If customers wish to use NEC Electronics products in applications not intended by NEC Electronics, they must contact an NEC Electronics sales representative in advance to determine NEC Electronics' willingness to support a given application. (Note) (1) "NEC Electronics" as used in this statement means NEC Electronics Corporation and also includes its majority-owned subsidiaries. (2) "NEC Electronics products" means any product developed or manufactured by or for NEC Electronics (as defined above). M8E 02. 11-1 4 User’s Manual U16525EJ1V0UM Regional Information Some information contained in this document may vary from country to country. Before using any NEC Electronics product in your application, pIease contact the NEC Electronics office in your country to obtain a list of authorized representatives and distributors. They will verify: • Device availability • Ordering information • Product release schedule • Availability of related technical literature • Development environment specifications (for example, specifications for third-party tools and components, host computers, power plugs, AC supply voltages, and so forth) • Network requirements In addition, trademarks, registered trademarks, export restrictions, and other legal issues may also vary from country to country. NEC Electronics America, Inc. (U.S.) Santa Clara, California Tel: 408-588-6000 800-366-9782 Fax: 408-588-6130 800-729-9288 NEC Electronics (Europe) GmbH Duesseldorf, Germany Tel: 0211-65 03 01 Fax: 0211-65 03 327 • Sucursal en España Madrid, Spain Tel: 091-504 27 87 Fax: 091-504 28 60 • Succursale Française Vélizy-Villacoublay, France Tel: 01-30-67 58 00 Fax: 01-30-67 58 99 • Filiale Italiana Milano, Italy Tel: 02-66 75 41 Fax: 02-66 75 42 99 NEC Electronics Hong Kong Ltd. • Branch The Netherlands Eindhoven, The Netherlands Tel: 040-244 58 45 Fax: 040-244 45 80 NEC Electronics Hong Kong Ltd. Hong Kong Tel: 2886-9318 Fax: 2886-9022/9044 Seoul Branch Seoul, Korea Tel: 02-528-0303 Fax: 02-528-4411 • Tyskland Filial Taeby, Sweden Tel: 08-63 80 820 Fax: 08-63 80 388 NEC Electronics Shanghai, Ltd. • United Kingdom Branch Milton Keynes, UK Tel: 01908-691-133 Fax: 01908-670-290 NEC Electronics Taiwan Ltd. Shanghai, P.R. China Tel: 021-6841-1138 Fax: 021-6841-1137 Taipei, Taiwan Tel: 02-2719-2377 Fax: 02-2719-5951 NEC Electronics Singapore Pte. Ltd. Novena Square, Singapore Tel: 6253-8311 Fax: 6250-3583 J02.11 User’s Manual U16525EJ1V0UM 5 [MEMO] 6 User’s Manual U16525EJ1V0UM PREFACE Target Readers This manual is intended for user engineers who design and develop application systems of the V850 Series. Purpose This manual is intended for users to understand the functions of the ID850NWC in the organization below. Organization This manual consists of the following chapters: • OVERVIEW • INSTALLATION • STARTING AND TERMINATING • ASSOCIATION WITH PM plus • FUNCTIONS OF ID850NWC • OPERATION • WINDOW REFERENCE • COMMAND REFERENCE How to Use This Manual It is assumed that the readers of this manual have general knowledge of electrical engineering, logic circuits, microcontrollers, C language, and assemblers. To understand the functions of the V850 Series → Refer to Hardware User's Manual for each product.. To understand the instruction functions of the V850 Series → Refer to V850ES Architecture User’s Manual (U15943E) or V850E1 Architecture User’s Manual (U14559E). Conventions Data significance: Higher digits on the left and lower digits on the right Note: Footnote for item marked with Note in the text Caution: Information requiring particular attention Remark: Supplementary information Numerical representation: Binary … XXXX or XXXXB Decimal ... XXXX Hexadecimal … 0xXXXX Prefix indicating the power of 2 (address space, memory capacity): 2 10 = 1024 M (Mega): 2 20 = 1024 K (Kilo): User’s Manual U16525EJ1V0UM 2 7 Related Documents Refer to the documents listed below when using this manual. The related documents indicated in this publication may include preliminary versions. However, preliminary versions are not marked as such. Documents related to development tools (User's Manuals) Document Name TM Document No. TM TM TM TM IE-703002-MC (In-circuit emulator for V853 , V850/SA1 , V850/SB1 , V850/SB2 , V850/SC1 , V850/SC2TM, V850/SC3TM, V850/SF1TM, V850/SV1TM) U11595E IE-V850E-MC (In-circuit emulator for V850E/IA1TM, V850E/IA2TM), IE-V850E-MC-A (In-circuit emulator for V850E/MA1TM, V850E/MA2TM) U14487E IE-V850E1-CD-NW(The N-wire emulator for V850E1,V850ES cores which carried on-chip debug unit) Under preparation IE-703003-MC-EM1 (In-circuit emulator option board for V853) U11596E IE-703017-MC-EM1 (In-circuit emulator option board for V850/SA1) U12898E IE-703037-MC-EM1 (In-circuit emulator option board for V850/SB1, V850/SB2) U14151E IE-703040-MC-EM1 (In-circuit emulator option board for V850/SV1) U14337E IE-703079-MC-EM1 (In-circuit emulator option board for V850/SF1) U15447E TM IE-703102-MC (In-circuit emulator for V850E/MS1, V850E/MS2 ) U13875E IE-703102-MC-EM1, IE-703102-MC-EM1-A (In-circuit emulator option board for V850E/MS1, V850E/MS2) U13876E IE-703107-MC-EM1 (In-circuit emulator option board for V850E/MA1) U14481E IE-703116-MC-EM1 (In-circuit emulator option board for V850E/IA1) U14700E CA850 Ver. 2.50 C Compiler Package Operation U16053E C Language U16054E PM plus U16055E Assembly Language U16042E ID850 Ver. 2.50 Integrated Debugger Operation U16217E ID850NWC Ver. 2.51 Integrated Debugger Operation This manual SM850 Ver. 2.50 System Simulator Operation U16218E SM850 Ver. 2.00 or Later System Simulator External Part User Open Interface Specifications U14873E RX850 Ver. 3.13 or Later Real-Time OS Basics U13430E Installation U13410E Technical U13431E Fundamental U13773E Installation U13774E Technical U13772E RX850 Pro Ver. 3.13 Real-Time OS 8 RD850 Ver. 3.01 Task Debugger U13737E RD850 Pro Ver. 3.01 Task Debugger U13916E AZ850 Ver. 3.10 System Performance Analyzer U14410E PG-FP4 Flash Memory Programmer U15260E User’s Manual U16525EJ1V0UM CONTENTS … CHAPTER 1 OVERVIEW 16 1.1Overview 16 1.2Features 16 1.3System Configuration 17 1.3.1 Example of system configuration 1.4 Operating Environment 18 1.4.1 Hardware environment 18 1.4.2 Software environment 18 1.5Notes on Source-Level Debugging 18 … … … … … … … … … … … 17 … CHAPTER 2 INSTALLATION 19 2.1Installing ID850NWC 19 2.1.1 Installing procedure 19 2.2ID850NWC Uninstalling 20 2.2.1 Uninstalling procedure 20 … CHAPTER 3 STARTING AND TERMINATING 3.1Cautions Before Starting 21 3.2 Starting 21 3.3Terminating 23 … … … … … 21 CHAPTER 4 ASSOCIATION WITH PM plus 24 4.1Setting Build Mode 24 4.2Registering Debugger to PM plus Project 24 4.2.1 Selecting debugger 24 4.2.2 Downloading multiple load module files 25 4.3To Start ID850NWC from PM plus 26 4.3.1 Restoring debugging environment 26 4.4Auto Load 27 4.4.1 Auto load by correcting source code 27 4.4.2 Auto load by starting debugger 27 … … … … … … … CHAPTER 5 FUNCTIONS OF ID850NWC 28 5.1Mapping Function 28 5.2Flash Memory Writing Function 29 5.3Setting Debugging Environment 29 5.4Program Execution Function 29 5.5Break Function 31 5.6Event Function 33 5.6.1 Using event function 33 5.6.2 Event condition 33 5.6.3 Event link condition 33 5.6.4 Setting of various event conditions 5.7Register Manipulation Function 34 5.8Memory Manipulation Function 34 5.9Watch Function 34 5.10Load/Save Function 35 5.10.1 view files 35 5.10.2 Information files 36 5.10.3 Setting files 36 5.11RAM Sampling Function 36 … … … … … … … … … … … … … … … 34 … … CHAPTER 6 OPERATION 37 6.1Flow of Debugging Operations 6.2Active Status and Static Status 6.3Jump Function 39 … CHAPTER 7 WINDOW REFERENCE 7.1Window List 41 … … … … … … … 37 … 39 … 41 User’s Manual U16525EJ1V0UM 9 7.2This section explains each debug window as follows: Main window 44 Configuration dialog box 62 Extended Option dialog box 68 Debugger Option dialog box 71 Font dialog box 78 Project File Save dialog box 80 Project File Load dialog box 83 View File Save dialog box 85 View File Load dialog box 88 Download dialog box 91 Upload dialog box 95 Load Module List dialog box 97 Browse dialog box 99 Source Text move dialog box 101 Address move dialog box 104 Symbol To Address dialog box 106 Source window 109 Source Search dialog box 121 Assemble window 124 Assemble Search dialog box 129 Memory window 132 Memory Search dialog box 137 Memory Fill dialog box 140 Memory Copy dialog box 142 Memory Compare dialog box 144 Memory Compare Result dialog box 146 DMM dialog box 148 Watch window 150 Quick Watch dialog box 156 Add Watch dialog box 159 Change Watch dialog box 163 Local Variable window 166 Stack Trace window 169 Register window 173 Register Select dialog box 176 IOR window 178 IOR Select dialog box 183 Add I/O Port dialog box 186 Event Manager 189 Software Break Manager 196 Event dialog box 199 Event Link dialog box 206 Break dialog box 212 Reset Debugger dialog box 216 Exit Debugger dialog box 218 About dialog box 220 Console window 221 … … … … … … … 42 … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … CHAPTER 8 COMMAND REFERENCE … 222 8.1Command Line Rules … 222 8.2Command List … 222 8.3List of Variables … 224 8.4List of Packages … 224 8.5Key Bind … 224 8.6Expansion window … 225 8.7Callback Procedure … 225 8.8Hook Procedure … 226 8.9Related Files … 227 8.10Cautions … 227 8.11Commands … 227 address 229 assemble 230 10 User’s Manual U16525EJ1V0UM batch 231 breakpoint 232 cache 234 dbgexit 236 download 237 extwin 238 finish 239 go 240 help 241 hook 242 ie 243 jump 244 mdi 246 memory 247 module 248 next 249 refresh 250 register 251 reset 252 run 253 step 254 stop 255 upload 256 version 257 watch 258 where 259 wish 260 … APPENDIX A N-WIRE CHECKER 261 A.1Overview 261 A.2Operation 262 A.3Explanation of each area and button 264 A.4Corrective Actions in Case of NG 266 A.5Restrictions 267 … … … … … … APPENDIX B EXPANSION WINDOW 268 B.1Overview 268 B.2 Activation 268 B.3Explanation of each sample window 268 List window 269 Grep window 270 RRM window 271 Hook window 272 Memory Mapped I/O window 274 Memory Mapped I/O dialog box 275 … … … … APPENDIX C INPUT CONVENTIONS 276 C.1Character set 276 C.2Symbols 277 C.3Numeric Values 277 C.4Expressions and Operators 278 … … … … APPENDIX D TERMINOLOGY D. 1Terminology 281 … … … 281 APPENDIX E MESSAGES 283 E.1Error/Warning Messages 283 E.1.1 Display format 283 E.1.2 Error messages at startup 284 E.1.3 Fatal error messages 285 E.1.4 Syntax error messages 291 E.1.5 Warning message or question message … … … … … … 309 User’s Manual U16525EJ1V0UM 11 … … APPENDIX F KEY FUNCTION LIST 312 F.1Function List of Special Function Keys 312 F.2Function List of Function Keys 313 F.3Function List of Special Function Keys (Shift + key) 313 F.4Function List of Function Keys (Shift + key) 314 F.5List of Special Function Keys (Ctrl + key) 314 F.6Function List of Function Keys (Ctrl + key) 314 F.7Function List of Control Keys (Ctrl + key) 314 F.8List of Special Function Keys (Ctrl + Shift + key) 315 APPENDIX G INDEX 12 … 316 … … … … … … … User’s Manual U16525EJ1V0UM LIST OF FIGURES Figure No. Title, Page 1-1 3-1 3-2 3-3 3-4 4-1 7-1 7-2 7-3 7-4 7-5 7-6 7-7 7-8 7-9 7-10 7-11 7-12 7-13 7-14 7-15 7-16 7-17 7-18 7-19 7-20 7-21 7-22 7-23 7-24 7-25 7-26 7-27 7-28 7-29 7-30 7-31 7-32 7-33 7-34 7-35 7-36 7-37 7-38 7-39 7-40 7-41 7-42 7-43 7-44 7-45 7-46 7-47 7-48 7-49 7-50 7-51 7-52 … Example of ID850NWC System Configuration 17 Configuration Dialog Box 21 Main Window 22 Exit Debugger Dialog Box 23 Message Box for Confirmation of Stopping Execution 23 Debugger Settings Dialog Box (PM plus) 25 Main Window 44 Toolbar with Only Graphics (default) 45 Toolbar with Graphics and Characters 45 Status Bar 59 Configuration Dialog Box 62 Extended Option Dialog Box 68 Debugger Option Dialog Box 71 Add Source path Dialog Box 73 Font Dialog Box 78 Project File Save Dialog Box 80 Project File Load Dialog Box 83 View File Save Dialog Box (Example: to Save Memory Window) View File Load Dialog Box 88 Download Dialog Box 91 The Progress of Download 94 Upload Dialog Box 95 Load Module List Dialog Box 97 Browse Dialog Box 99 Source Text Move Dialog Box 101 Address Move Dialog Box 104 Symbol To Address Dialog Box 106 Source Window 109 Source Search Dialog Box 121 Assemble Window 124 Assemble Search Dialog Box 129 Memory Window 132 Memory Search Dialog Box 137 Memory Fill Dialog Box 140 Memory Copy Dialog Box 142 Memory Compare Dialog Box 144 Confirmation Dialog Box 145 Memory Compare Result Dialog Box 146 DMM Dialog Box 148 Watch Window 150 Quick Watch Dialog Box 156 Add Watch Dialog Box 159 Change Watch Dialog Box 163 Local Variable Window 166 Stack Trace Window 169 Register Window 173 Register Select Dialog Box 176 IOR Window 178 IOR Select Dialog Box 183 Add I/O Port Dialog Box 186 Event Manager 189 Software Break Manager 196 Event Dialog Box 199 Event Link Dialog Box 206 Break Dialog Box 212 Reset Debugger Dialog Box 216 Exit Debugger Dialog Box 218 About Dialog Box 220 … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … User’s Manual U16525EJ1V0UM … … 85 13 7-53 A-1 A-2 B-1 B-2 B-3 B-4 B-5 B-6 E-1 14 … … Console Window 221 N-Wire Checker 261 Waveform of N-Wire Checker 263 List Window 269 Grep Window 270 RRM Window 271 Hook Window 272 Memory Mapped I/O Window 274 Memory Mapped I/O Dialog Box 275 Error/Warning Messages 283 … … … … … … … … User’s Manual U16525EJ1V0UM LIST OF TABLES Table No. Title, Page 5-1 5-2 5-3 5-4 7-1 7-2 7-3 7-4 7-5 7-6 7-7 7-8 7-9 7-10 7-11 7-12 7-13 7-14 7-15 7-16 7-17 7-18 7-19 7-20 7-21 7-22 7-23 7-24 7-25 7-26 7-27 8-1 8-2 8-3 A-1 B-1 C-1 C-2 C-3 C-4 C-5 C-6 D-1 F-1 F-2 F-3 F-4 F-5 F-6 F-7 F-8 … … … … Various Event Conditions 33 List of View Files 35 List of Information Files 36 List of Setting Files 36 Window List 41 Break Cause 60 Mapping Unit in Configuration Dialog Box 67 Contents Saved to Project File 80 Extension Corresponding to Current Window 86 Type of File That Can Be Loaded on View File Load Dialog Box 89 Type of File That Can Be Downloaded 92 Type of File That Can Be Uploaded 96 Type of File That Can Be Displayed in Browse Dialog Box 100 Specifying Symbols 107 Display Color of Breakpoint and Its Meaning 111 Details of Setting/Deleting Breakpoint 112 Meaning of Event Display Mark 112 Details of Drag & Drop Function (Line/Address) 119 Details of Drag & Drop Function (Character String) 120 Data Display Format (Watch-Related) 152 How a Variable Is Handled When a Scope Is Specified 160 Maximum Number of Valid Events for Each Event Condition 189 Marks of Event Icon 191 Color of Character on Mark and its Meaning 191 Address Condition and Jump Pointer 192 Separator for Displaying Event Details 193 List of Status Conditions 201 List of Access Size Conditions (Event) 201 Settable Range of Data Condition 203 The Number of Event Conditions in Event Link Dialog Box 208 Number of Events Settable in Break Condition Setting Area 213 List of Debugger Control Commands 222 List of Console/Tcl Commands 224 Message ID 225 Errors(N-Wire Checker) 266 List of Expansion Window 268 Usable Character Set 276 List of Special Characters 276 Input Format of Numeric Values 278 List of Operators 278 Operator Priority 279 Range of Radixes 280 Delimiter 281 Function List of Special Function Keys 312 Function List of Function Keys 313 Function List of Special Function Keys (Shift + key) 313 Function List of Function Keys (Shift + key) 314 List of Special Function Keys (Ctrl + key) 314 Function List of Function Keys (Ctrl + key) 314 Function List of Control Keys (Ctrl + key) 314 List of Special Function Keys (Ctrl + Shift + key) 315 … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … User’s Manual U16525EJ1V0UM 15 CHAPTER 1 OVERVIEW CHAPTER 1 OVERVIEW 1.1 Overview The integrated debugger ID850NWC for the V850 Series. (hereafter referred to as the ID850NWC) is a software tool developed for NEC Electronics V850 Series. of 32-bit micro controllers for embedded control. This software tool is intended to enable efficient debugging of user programs. 1.2 Features The ID850NWC has the following features: (1) Source debugging A C source program and source program in assembly language can be debugged. (2) Support of on-chip debugging A debugging function implemented by the on-chip debug unit of the Nx85ET(RCU0+TEU+TRCU), Nx85E901(RCU0), RCU1 is provided. (3) Flash memory writing function The internal flash memory can be written and the load module can be downloaded by the same access method as an ordinary memory operation. (4) Security function The ID code stored in the internal ROM or internal flash memory of a product with a security unit can be authenticated. (5) Execution time measurement function Time from the start of user program execution to occurrence of a break (Run-Break time) is measured in a range of 100 ns to 214 seconds. (6) Automatic display updating function when execution is stopped If execution of the user program is stopped, the values of the window displayed on the screen are automatically updated. (7) Saving/restoring debugging environment The debugging environment including information on setting of breakpoints and events, downloading files, and display status and position of windows can be saved to a file (project file). By loading this project file, the debugging environment can be restored. 16 User’s Manual U16525EJ1V0UM CHAPTER 1 OVERVIEW (8) Batch execution by command and creation of custom window A console window that allows batch processing on the command line and creation of the user's own custom window has been added. 1.3 System Configuration The ID850NWC provides a comfortable debugging environment for user programs and target systems developed for the V850 Series, by manipulating the PC card type emulator IE-V850E1-CD-NW that is inserted in the host machine. The IE-V850E1-CD-NW is an emulator for on-chip debugging that provides debugging functions by being connected to the target system that incorporates the V850ES or V850E1 with a built-in RCU (Run Control Unit). 1. 3. 1 Example of system configuration Figure 1-1 shows an example of the system configuration of the ID850NWC. Figure 1-1 Example of ID850NWC System Configuration Host machine IE-V850E1-CD-NW Target system (With microcontroller with RCU) User’s Manual U16525EJ1V0UM 17 CHAPTER 1 OVERVIEW 1.4 Operating Environment The ID850NWC has the following hardware and software requirements: 1. 4. 1 Hardware environment (1) Host machine • IBM PC/AT TM -compatible machine Caution Because it is assumed that the ID850NWC is used with a notebook PC, the host machine must have a PC card slot (TYPEII). (2) In-circuit emulator • IE-V850E1-CD-NW 1. 4. 2 Software environment (1) Operating system (any of the following) Windows 98, Windows 2000, Windows NT 4.0 (Service Pack 5 or above), WindowsMe, WindowsXP Home Edition, WindowsXP Professional Edition Caution Regardless of which of the OS’s above is used, we recommend that the latest Service Pack is installed. (2) device file (Individual acquisition) • The device file of the target device to be used. This file is available from the following Web site of NEC Electronics Corporation. http://www.necel.com/micro/index_e.html 1.5 Notes on Source-Level Debugging To perform source-level debugging, add an option (-g option) to generate debug information when the source file is compiled. If this option is not added, the source file cannot be debugged at the source level. In addition, the following processing must be performed for the ID850NWC. • Embedding ID code (refer to "IE-V850E1-CD-NW User's Manual") • Storing program in ROM (recommended) (refer to "CA850 C Compiler Package - Operation") 18 User’s Manual U16525EJ1V0UM CHAPTER 2 INSTALLATION CHAPTER 2 INSTALLATION This chapter explains the procedure of installing and uninstalling ID850NWC. 2.1 Installing ID850NWC To use the ID850NWC, the ID850NWC and a device file are necessary. Install the device file with the dedicated installer "DFINST.exe" (supplied with the ID850NWC). 2. 1. 1 Installing procedure To install the ID850NWC, prepare the following: • ID850NWC system disk Install the ID850NWC by inserting the ID850NWC system disk in the CD-ROM drive and then following the installer's instructions. Caution To install the ID850NWC again after the ID850NWC has been installed once, be sure to uninstall the ID850NWC. If the ID850NWC is installed in a directory different from that, without uninstalling, the ID850NWC that has already been installed cannot be uninstalled. User’s Manual U16525EJ1V0UM 19 CHAPTER 2 INSTALLATION 2.2 ID850NWC Uninstalling 2. 2. 1 Uninstalling procedure 1 Start [Add/Remove Programs] from the Control Panel. 2 Select [NEC ID850NWC V850 Integrated Debugger] from the list displayed at [Install and Uninstall], and click the < Add/Remove...> button. 3 [Confirm File Deletion] dialog box will be displayed. Click the <Yes > button. 4 The program will be deleted. When the message " Uninstalling is complete." is displayed, click the <OK> button. 20 User’s Manual U16525EJ1V0UM CHAPTER 3 STARTING AND TERMINATING CHAPTER 3 STARTING AND TERMINATING This chapter explains the procedure of starting and terminating the ID850NWC. 3.1 Cautions Before Starting Start the N-Wire Checker before the starting the ID850NWC to check that the in-circuit emulator and the target system can be normally debugged (refer to "APPENDIX A N-WIRE CHECKER"). Caution For the connection between the in-circuit emulator and the target system and the power application sequence, refer to "IE-V850E1-CD-NW User's Manual". Incorrect connection may damage the in-circuit emulator and the target system. 3.2 Starting 1 Select [Start] -> [Program] -> [NEC Tools32] -> [ID850NWC] from the Windows start menu. Start the ID850NWC, the Configuration dialog box will be opened. In this case, the Configuration dialog box should not be displayed, but an error message should be displayed, please cope with it with reference to "E. 1. 2 Error messages at startup" Figure 3-1 Configuration Dialog Box User’s Manual U16525EJ1V0UM 21 CHAPTER 3 STARTING AND TERMINATING 2 Set the items related to the operating environment of the ID850NWC in the Configuration dialog box. After setting each item, click the <OK> button in the dialog box. 3 The Main window will be opened and the ID850NWC can be operated. Mainly use this window for debugging. Figure 3-2 22 Main Window User’s Manual U16525EJ1V0UM CHAPTER 3 STARTING AND TERMINATING 3.3 Terminating Terminate the ID850NWC as follows: 1 Select [File] -> [Exit] on the Main window. The following Exit Debugger dialog box will be opened: Figure 3-3 Exit Debugger Dialog Box If the above operation is performed while the user program is being executed, the dialog box shown in Figure 3-4 is opened. In this case, clicking the <Yes> button opens the Exit Debugger dialog box. Figure 3-4 2 Message Box for Confirmation of Stopping Execution To save the current debugging environment to a project file, click the <Yes> button. If the <No> button is clicked, all the windows are closed the ID850NWC terminated. User’s Manual U16525EJ1V0UM 23 CHAPTER 4 ASSOCIATION WITH PM plus CHAPTER 4 ASSOCIATION WITH PM plus This chapter explains the procedure and points to be noted when a function to associate the PM plus is used. The ID850NWC can automatically perform a series of operations in development processes, such as creating source files -> compiling -> debugging -> correcting source files, in association with the PM plus. Caution If a load module file is created by using the Windows command prompt, the function to associate the ID850NWC with the PM plus cannot be used. 4.1 Setting Build Mode To debug the load module file created by the PM plus on the ID850NWC at the source level, build to output symbol information for debugging must be performed to create a load module file. This setting can be performed by selecting [Debug Build] on the PM plus. 4.2 Registering Debugger to PM plus Project The debugger to be used or the load module files to be downloaded can be specified for each project in the PM plus. 4. 2. 1 Selecting debugger The procedure for selecting the debugger is as follows: Creating a new workspace 1 Select [File] menu -> [New Workspace...] on the PM plus. -> This opens the dialog box to create a new workspace using the wizard format. 2 Creating the necessary settings for the workspace with the wizard, the [New Workspace - Step 7/8 (Select Debugger)] dialog box will be opened. Specify [ID850NWC V850 Integrated Debugger] in this dialog box. -> For details of the setting, refer to the PM plus online help or user's manual. Using an existing workspace 1 Select [Tool] menu -> [Debugger Settings...] on the PM plus. -> The Debugger Settings dialog box will be opened. 2 Specify [ID850NWC V850 Integrated Debugger] and click the <OK> button in this dialog box. The ID850NWC is registered as the debugger of the active project. The ID850NWC icon is displayed on the toolbar of the PM plus. 24 User’s Manual U16525EJ1V0UM CHAPTER 4 ASSOCIATION WITH PM plus 4. 2. 2 Downloading multiple load module files The load module files of the same project group are downloaded to the ID850NWC. For details of the project group, refer to the PM plus online help or user's manual. Download multiple load module files in the following steps. 1 Select [Tool] menu -> [Debugger Settings...] on the PM plus. -> The Debugger Settings dialog box will be opened. Figure 4-1 Debugger Settings Dialog Box (PM plus) 2 Specify [ID850NWC V850 Integrated Debugger] in this dialog box. 3 Specify the load module file to be downloaded first in the [Debug Target File] when the ID850NWC is started. 4 Check the [Download the debug target files in the same project group] check box, and select the debug target files in the same group to be downloaded in the Debug Target File List. ->The selected file will be downloaded right after the file specified in [Debug Target File] when the ID850NWC is started. Note that when these files are downloaded, symbol reset and CPU reset are not executed. 5 Click the <OK> button. Remark Multiple load module files that are being downloaded can be checked in the Load Module List dialog box of the ID850NWC. Caution If [execute symbol reset after dowmload] in the [Debugger Settings...] dialog box of the product with a internal flash memory is checked, the contents of the internal flash memory are erased before downloading. User’s Manual U16525EJ1V0UM 25 CHAPTER 4 ASSOCIATION WITH PM plus 4.3 To Start ID850NWC from PM plus The ID850NWC can be started from the PM plus as follows: • Click the ID850NWC starting button on the toolbar of the PM plus. • Select the [Build] menu -> [Debug] on the PM plus. • Select the [Build] menu -> [Build and Debug] on the PM plus. • Select the [Build] menu -> [Rebuild and Debug] on the PM plus. If the debugging environment of the ID850NWC is saved to a project file currently being used by the PM plus, it will be started in the debugging environment saved in the project file. If the debugging environment of the ID850NWC is not saved to a project file being used by the PM plus, the Configuration dialog box is opened. At this time, the device type (Chip name) cannot be changed. 4. 3. 1 Restoring debugging environment The previous debugging environment can be restored by the following procedure when the ID850NWC is started from the PM plus: 1 Create a new workspace (project file: e.g., sample.prj) on the PM plus. Caution In the ID850NWC and PM plus, the environment information is saved to a project file and referenced. The extension of the project file that can be used by the ID850NWC and PM plus is "prj". For the information that is saved or restored by the project file, refer to the online help or the user's manual of each product. 2 Start the ID850NWC from the PM plus. Because a new project file is created, set items other than the device type (Chip name) in the Configuration dialog box in the same manner as when only the ID850NWC is started. 3 Download the load module file to be debugged with the Download dialog box of the ID850NWC. 4 Debug the load module file on the ID850NWC. 5 Click the <Yes> button on the Exit Debugger dialog box when the ID850NWC is terminated. -> The debugging environment will be saved to the project file (sample.prj) for the PM plus when the ID850NWC is terminated (the debug environment can also be saved to the sample.prj file by overwriting the project file at times other than the completion of ID850NWC debugging). 6 When the ID850NWC is next started up after the sample.prj file is read by PM plus, the debug environment at the point when the project file was saved is automatically restored. 26 User’s Manual U16525EJ1V0UM CHAPTER 4 ASSOCIATION WITH PM plus 4.4 Auto Load If a bug is found while the load module file is being debugged by the ID850NWC, correct the source file using the following procedure. Compiling and re-downloading the file can be automatically executed (Refer to "Auto load by correcting source code"). The load module is downloaded again to the ID850NWC by compiling and linking the file on the PM plus with the activated ID850NWC (refer to "Auto load by starting debugger"). 4. 4. 1 Auto load by correcting source code Correct the source file for auto load as follows: 1 Open the source file to be corrected in the Source window. Select [File] menu -> [Open] and specify the file to be corrected on the ID850NWC (if the file is already open in the Source window, that window is displayed in the forefront). -> The specified file will be opened in the Source window. 2 Select [Edit] menu -> [Correct Source] on the ID850NWC. -> An editor will be opened and the specified source file will be read. 3 Correct the source file on the editor. 4 Terminate the editor. Caution The CPU reset is not performed when the load module file is automatically downloaded. The debug window that was opened when the editor was called, and each event setting will be restored. If the previously used line or symbol has been deleted as a result of correcting the source file, the following happens: - A variable that was displayed is dimmed. - The event mark of an event condition is displayed in yellow. 5 4. 4. 2 Select [Build] menu -> [Build and Debug], or [Build] -> [Rebuild and Debug] on the PM plus. Auto load by starting debugger If the following operation is performed on the PM plus with the ID850NWC started, the load module will be automatically downloaded to the ID850NWC. • Selecting the [Build] menu -> [Build and Debug] on the PM plus. • Selecting the [Build] menu -> [Rebuild and Debug] on the PM plus. The CPU reset is not performed after the load module has been downloaded. User’s Manual U16525EJ1V0UM 27 CHAPTER 5 FUNCTIONS OF ID850NWC CHAPTER 5 FUNCTIONS OF ID850NWC This chapter explains the basic debugging function of the ID850NWC. • Mapping Function • Flash Memory Writing Function • Setting Debugging Environment • Program Execution Function • Break Function • Event Function • Register Manipulation Function • Memory Manipulation Function • Watch Function • Load/Save Function • RAM Sampling Function 5.1 Mapping Function The following types of mapping functions are available: The mapping configuration is done by Configuration dialog box. (1) User area mapping (Target) The memory area specified for user area mapping becomes the area to accesses the memory in the target system or memory incorporated in the CPU. (2) I/O Protect area An I/O Protect area can be set in the area specified for the "target". This area is displayed in the same manner as an area that is not mapped (display symbol:??), on the Memory window. By mapping an area with this attribute, data cannot be read or written from/to this area by the Memory window, on the area can therefore be protected from an illegal access. To read or write the value of the area mapped with this attribute, register the value in the IOR window or Watch window. 28 User’s Manual U16525EJ1V0UM CHAPTER 5 FUNCTIONS OF ID850NWC 5.2 Flash Memory Writing Function With the ID850NWC, the internal flash memory can be written and the load module can be downloaded by the same access method as an ordinary memory operation. The data on the internal flash memory can be changed from the Memory window, Assemble window, Watch window, Memory Fill dialog box, and Memory Copy dialog box, without having to be aware that the data is that of the internal flash memory. The load module can also be downloaded to the internal flash memory by using the flash self-programming function. Caution No data can be written to the internal flash memory during user program execution. Remark With the ID850NWC, the remaining area contents after the load module was downloaded to the internal flash memory are erased. 5.3 Setting Debugging Environment Set a debugging environment with the Configuration dialog box that is opened when the debugger is started, or the Extended Option dialog box or Debugger Option dialog box. By creating a file (project file) to which the current debugging environment is saved during debugging, and loading this file, the debugging environment when the project file is saved can be restored. To manipulate the project file, use the Project File Save dialog box and Project File Load dialog box. After the project file has been loaded, the size and position of the displayed window are returned to the previous size and status (refer to Table 7-4 Contents Saved to Project File). To load the project file when starting up the debugger, press the <Project...> button in the Configuration dialog box. It can also be specified that the project file is automatically loaded each time the debugger is started up (refer to To automatically load a project file). 5.4 Program Execution Function The ID850NWC has the following execution functions. Manipulation of these functions is done with the [run] menu or the function buttons. • [Go] (Go button) • [Ignore break points and Go] (GoN button) • [Return Out] (Ret button) • [Step In] (Step button) • [Next Over] (Over button) • [Start From Here] • [Come Here] • [Go and Go] • [Slowmotion] • [Restart] (ReGo button) User’s Manual U16525EJ1V0UM 29 CHAPTER 5 FUNCTIONS OF ID850NWC (1) [Go] (Go button) The user program is executed starting from the address indicated by the current PC register and is stopped if a set break event condition is satisfied. (2) [Ignore break points and Go] (GoN button) This command executes the user program starting from the address indicated by the current PC register. Execution of the user program continues, ignoring set breakpoints. (3) [Return Out] (Ret button) The user program is executed until execution returns to the calling function described in C language. (4) [Step In] (Step button) The operation differs depending on whether this function is executed in the Source window or the Assemble window. In the Source window Step execution of one line of the source text is performed starting from the current PC register value and the contents of each window are updated. In the Assemble window One instruction is executed from the current PC register value and the contents of each window are updated. (5) [Next Over] (Over button) The operation differs depending on whether the instruction to be executed is the jarl instruction or any other instruction. jarl instruction Next step execution is performed, assuming the function or subroutine called by the jarl instruction as one step (step execution continues until the nesting level becomes the same as when the jarl instruction was executed). Instruction other than jarl The same processing as [Step In] is performed. (6) [Start From Here] This command executes the user program starting from the specified address. Execution of the user program is stopped when a set break event condition is satisfied. (7) [Come Here] The user program is executed from the address indicated by the current PC register to the address selected in the line/address display area of the Source window or the Assemble window, and then a break occurs. While the user program is being executed, the break event currently set does not occur. 30 User’s Manual U16525EJ1V0UM CHAPTER 5 FUNCTIONS OF ID850NWC (8) [Go and Go] The user program is executed starting from the address indicated by the current PC register and stopped if a set break event condition is satisfied. The contents of each window are updated, and execution of the user program is resumed from the address at which the program was stopped.This operation is repeated until the user executes [Stop]. (9) [Slowmotion] Step execution of one line is performed from the address indicated by the current PC register value in the source mode. In the instruction mode, step execution of one instruction is performed. The contents of each window are updated each time step execution is performed. This operation is repeated until the user executes [Stop]. (10) [Restart] (ReGo button) The CPU is reset and the user program is executed starting from address 0. This is the same operation as "resetting the CPU before execution of the user program and executing [Go]". 5.5 Break Function The ID850NWC has the following break functions. • Event detection break • Break by [Come Here] • Software break • Break on satisfaction of condition of step execution • Forced break ([Stop], Stop button) Caution The event detection break and Software break are not performed when [Come Here], [Step In], [Return Out], [Next Over], or [Ignore break points and Go] described in "Program Execution Function" is executed. (1) Event detection break Event detection break is a function used to stop execution of the user program by detecting a set break event condition. This break is valid for [Go], [Go and Go], [Start From Here], and [Restart]. In the case of [Automatically Continue Execution], however, the contents of each window are updated and the user program is executed again after the event detection break has occurred. Set a break event as follows: • Set as an execution event in the Source window or Assemble window (refer to Breakpoint setting/ deletion function) • Set in Break dialog box. User’s Manual U16525EJ1V0UM 31 CHAPTER 5 FUNCTIONS OF ID850NWC Caution Event detection break point set/overwrite/delete is possible during user program execution. In that case, The warning of a purport which makes a user program once take a break is displayed. (2) Break by [Come Here] The function stops execution of a user program executed with the [Come Here] upon detection of the address specified in the Source window or Assemble window. After user program execution has been stopped, the breakpoint by this function is eliminated. Moreover, during execution of a user program by [Come Here], break events set before the cursor position does not occur. (3) Software break Software break is a function to replace the instruction at the specified address software break instruction and stop the user program executed by the [Go], [Go and Go], [Start From Here], or [Restart] command. As many software break events as necessary can be set (however, only 2000 of them are valid). Because the instruction at the specified address is rewritten, however, a software break event cannot be set on the external ROM or stopped by the access timing of a variable. While one event detection break uses one hardware resource per event condition, the feature of a software break is that a breakpoint is set at two or more addresses. Software break events are set in the Source window or Assemble window. (Refer to Breakpoint setting/deletion function.) The Software Break Manager manages the software breaks (by validating or invalidating). Cautions 1 The 2000 valid addresses include the valid number of addresses when a software break is set in the internal ROM and internal flash memory. Because the ID850NWC realizes setting of software breaks in these areas by using the ROM correction function, the max number of addresses depends on the product type (0, 4, or 8). Caution 2 Software breaks can be set or deleted while the user program is being executed. In that case, The warning of a purport which makes a user program once take a break is displayed. (4) Break on satisfaction of condition of step execution Break on satisfaction of condition of step execution is a function used to stop execution of the user program when the end condition of each command ([Step In], [Next Over], [Return Out], and [Slowmotion]) is satisfied. Because one instruction is executed, stopped, and the condition is confirmed at one time, the processing time is longer than that of real-time execution. (5) Forced break ([Stop], Stop button) Forced break is a function used to forcibly stop execution of the user program. It is valid for all the execution commands. 32 User’s Manual U16525EJ1V0UM CHAPTER 5 FUNCTIONS OF ID850NWC 5.6 Event Function An event is a specific status of the target system during user program execution, such as "address 0x1000 is fetched" or "data is written to address 0x2000". The ID850NWC uses an event to trigger an action of functions such as break functions. An event function is used to set, delete, and reference a specific status of the target system that triggers an action (debugging action) as an event condition. 5. 6. 1 Using event function So that an action that is triggered by an event function in accordance with the user's debugging aim, the following various event conditions must be set. Table 5-1 Set Condition Break event condition Various Event Conditions Setting Dialog Box Break dialog box Contents Condition in which the execution of the user program is stopped. These various event conditions are set independently as an Event condition or Event link condition, or as a combination of these. To use the event function of the ID850NWC, therefore, first create the necessary Event condition and Event link condition, and set the various event conditions shown in the Table 5-1 by using these conditions. 5. 6. 2 Event condition Create an event condition in the Event dialog box. Set an address condition, status condition, and data condition in this dialog box. Specify a combination of these as one event condition and name and register this event condition. The registered event condition can be used to set various event conditions. However, the number of event conditions that can be set is limited. The event condition that is created when a breakpoint is set in the Source window or the Assemble window can also be used (refer to "Breakpoint setting/deletion function"). 5. 6. 3 Event link condition An event link condition specifies sequential constraints for each event, so that two or more events are treated as a single event. To create an event link condition, use the Event Link dialog box. By arranging already registered event conditions in this dialog box, one event link condition can be named and registered. The registered event link condition can be used to set various event conditions in the same manner as the event condition. However, the number of event conditions that can be set is limited. User’s Manual U16525EJ1V0UM 33 CHAPTER 5 FUNCTIONS OF ID850NWC 5. 6. 4 Setting of various event conditions Various event conditions listed in Table 5-1 are individually created in the corresponding dialog box. To create various event condition, drag and drop the event icon of an event condition or event link condition registered on the Event Manager to the condition area of each setting dialog box. The created various event condition is set by clicking the <Set> or <OK> button in the setting dialog box. The mark of the event that has been set is displayed in red. After the event has been set, a debugging action occurs as various event conditions. Up to 256 various event conditions can be registered. The number of various event conditions that can be "set" differs depending on the various event condition (refer to "Table 7-18 Maximum Number of Valid Events for Each Event Condition"). 5.7 Register Manipulation Function The register manipulation function is used to display or change the contents of the program registers, system registers, and peripheral I/O registers. This function can be used in the Register window or IOR window. To change the register to be displayed in each window, use the Register Select dialog box or IOR Select dialog box. A user-defined I/O port can be displayed or changed by registering it to the Add I/O Port dialog box. With a product that supports programmable I/O registers, the programmable I/O registers can be displayed or changed by specifying the use of the programmable I/O area in the Configuration dialog box. 5.8 Memory Manipulation Function As a memory manipulation function, the memory contents can be displayed or changed by using mnemonic codes, hexadecimal codes, and ASCII codes. This function can be used in the Memory window or Assemble window. The contents of memory can be copied, initialized, and compared. Note that the memory contents can also be rewritten in the DMM dialog box. 5.9 Watch Function Data (variable) values can be checked or changed in the Watch window. Local variables can be checked or changed in the Local Variable window. The contents of a variable value can be easily referenced in the Source window or Assemble window by placing the mouse cursor on the selected variable (balloon watch function). 34 User’s Manual U16525EJ1V0UM CHAPTER 5 FUNCTIONS OF ID850NWC 5.10 Load/Save Function The load/save function is used to load/save each file. The ID850NWC loads/saves each file individually. These three types of files can be handled: 5. 10. 1 view files File recording the screen information when it is saved. By loading this file, a reference file is opened in the Source window. information file File recording the set data and debugging environment as information on the user program and ID850NWC. setting files File recording the window information. view files The list of the view files to be handled is shown below: These files can be manipulated in the View File Load dialog box and View File Save dialog box. Table 5-2 List of View Files File Type Contents Source Text (*.SVW) Source window view file Records the source text in the Source window. Assemble (*.DIS) Assemble window view file Records the assembly information in the Assemble window. Memory (*.MEM) Memory window view file Records the memory information in the Memory window. Register (*.RGW) Register window view file Records the register information in the Register window. Local Variable (*.LOC) Local Variable window view file Records the local variable information in the Local Variable window. Stack Trace (*.STK) Stack Trace window view file Records the stack trace information in the Stack Trace window. Console (*.LOG) Console window view file Records the information in the Console window. User’s Manual U16525EJ1V0UM 35 CHAPTER 5 FUNCTIONS OF ID850NWC 5. 10. 2 Information files The list of the information files to be handled is shown below. Table 5-3 File Name (Extension) List of Information Files Contents Dialog Box , Object file (*.HEX) Stores the object codes of the user program. Download dialog box Upload dialog box Load module file (*.OUT) Stores the object codes, symbols, and source information of the user program. Download dialog box project file (*.PRJ) Stores the debugging environment Project File Load dialog box Project File Save dialog box Binary file (*.BIN) Records data in binary format. Download dialog box Upload dialog box , , A project file sets the display information, size, and display position of a window or dialog box, and restores the debugging environment to the previous status (when the project file was saved) when it is loaded. 5. 10. 3 Setting files The list of the setting files to be handled is shown below: These files can be manipulated in the View File Load dialog box and View File Save dialog box. Table 5-4 List of Setting Files File Name (Extension) 5.11 Contents Watch setting file (*.WCH) Stores the watch setting contents of the Watch window. Peripheral I/O register setting file (*.IOR) Stores the peripheral I/O register setting contents of the IOR window. Event setting file (*.EVN) Stores the event setting contents of the Event Manager. RAM Sampling Function The RAM sampling functions are used to read and display the memory contents, even during user program execution, if a variable allocated to a range in which the memory contents can be read, or the memory contents are displayed. This function can be checked in the Watch window, Memory window or IOR window. Settings related to this function are performed in the Extended Option dialog box. 36 User’s Manual U16525EJ1V0UM CHAPTER 6 OPERATION CHAPTER 6 OPERATION This chapter explains the flow of basic debugging operations using the ID850NWC and the following functions: • Flow of Debugging Operations • Active Status and Static Status • Jump Function 6.1 Flow of Debugging Operations (1) Setting debugging environment Prepare for debugging. -> Configuration dialog box Download a load module file to be debugged. -> Download dialog box Checking the loaded file. -> Load Module List dialog box (2) Displaying source program By downloading a load module file with debug information, the corresponding source file is automatically displayed. -> Source window (3) Displaying disassemble result The disassembled result of the downloaded user program is displayed. -> Assemble window (4) Setting breakpoint Breakpoints can be set easily in the Source window, Assemble window, and Watch window. -> Breakpoint setting/deletion function -> To set a breakpoint for read/write access to a variable (5) Setting event Register event conditions and event link conditions. -> Event dialog box, Event Link dialog box Setting of various event conditions Set a various event condition by using the Event Manager or an event icon in the event manager area on each various event setting dialog box. Each various event condition corresponds to the following various event setting dialog box. Break event condition -> Break dialog box User’s Manual U16525EJ1V0UM 37 CHAPTER 6 OPERATION Checking setting status of various event conditions -> Event dialog box or the event manager area in each various event setting dialog box Checking setting status of software breakpoint -> Software Break Manager (6) Executing user program By executing the user program, the PC advances to the set breakpoint, break event, or forced breakpoint (refer to "Program Execution Function"). Use the execution control button or [Run] menu to execute the user program. (7) Editing, checking, and changing memory contents -> Memory window, Memory Copy dialog box, Memory Fill dialog box, Memory Compare dialog box, Memory Compare Result dialog box, DMM dialog box (8) Registering, checking, and changing variable value -> Watch window, Quick Watch dialog box, Add Watch dialog box, Change Watch dialog box, Local Variable window (9) Checking stack contents -> Stack Trace window (10) Checking and changing of registered contents of register value -> Register window, Register Select dialog box The value of the PC register can also be checked in the Source window and Assemble window. (11) Checking and changing peripheral I/O register value -> IOR window, IOR Select dialog box (12) Registering, checking, and changing user-defined I/O port value -> Add I/O Port dialog box, IOR window (13) Changing mnemonic and executing online assembly -> Assemble window, Source window (14) Searching character string in each window By clicking the < Search...> button in the window in which searching is to be executed, the following types of searching dialog boxes are opened: Source Search dialog box, Assemble Search dialog box, Memory Search dialog box (15) Manipulating view file -> View File Save dialog box, View File Load dialog box 38 User’s Manual U16525EJ1V0UM CHAPTER 6 OPERATION (16) Uploading memory contents and coverage result -> Upload dialog box (17) Saving debugging environment to project file -> Project File Save dialog box (18) Terminating ID850NWC -> Exit Debugger dialog box 6.2 Active Status and Static Status The Source window, Assemble window, and Memory window have the following two window statuses: Active status The display position and contents of the window in the active status are automatically updated in association with the current PC value. This window is also the jump destination of the jump function. Only one window can be opened in the active status. Select this status by the [Window] menu. Static status The display position of the window in the static status does not move in association with the current PC value, but the displayed contents are updated. The static window is not used as the jump destination of the jump function. In addition. If an active window is already open, the next window is opened in the static status. Two or more static windows can be opened at the same time. Select this status by the [Window] menu. Because two or more static windows can be opened, the current status of the windows can be temporarily held. 6.3 Jump Function The jump function is used to jump to Source window, Assemble window, or Memory window from a jump pointer that is the line or address on which the cursor is placed, and display the contents of the jump destination window from the jump pointer. You can jump among the above windows, or from Stack Trace window, Event Manager, and Register window to the above windows. Jump method 1 Move the cursor to the line or address that is to be used as the jump pointer, on the window from which jumping is possible (select an event icon on the Event Manager). 2 Select the following menu item to which execution is to jump from the [Jump] menu. Source window->Select [Source]. Assemble window->Select [Assemble]. Memory window->Select [Memory]. User’s Manual U16525EJ1V0UM 39 CHAPTER 6 OPERATION Caution If a program code does not exist on the line at the cursor position, the first address of the line with a program code above or below that line is used as the jump pointer. Details of jump source address To jump from the following windows, the jump destination is as follows: • To jump from the Register window, move the cursor to a register value. • To jump from the Stack Trace window, the jump destination is as follows: [With current function] • If the jump destination is the Source window -> Jumps to the current PC line. • If the jump destination is a window other than the Source window -> Jumps to the current PC address. [With function other than current function] • If the jump destination is the Source window -> Jumps to the line that calls a nested function. • If the jump destination is a window other than the Source window -> Jumps to the address next to the instruction that calls a nested function. 40 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE CHAPTER 7 WINDOW REFERENCE This chapter explains the details of the window/dialog box functions of the ID850NWC. 7.1 Window List Table 7-1l ists the windows of the ID850NWC. Table 7-1 Window List Window Name Contents Main window This window is displayed first, when the ID850NWC is started. It controls execution of the user program. Various windows are opened from this window. Configuration dialog box Displays and sets the ID850NWC operation environment. Extended Option dialog box This dialog box is used to display and set the extended options of the ID850NWC. Debugger Option dialog box Displays and sets options. Font dialog box Displays the types of fonts displayed in the Source window and sets the size of the font. Project File Save dialog box Saves the debug environment. Project File Load dialog box Loads the debug environment. View File Save dialog box Saves the contents of the current window to a view file or event setting file. View File Load dialog box Reads the view file or source event setting file of each window. Download dialog box Loads an object file and binary file. Upload dialog box Saves the memory contents to a file. Load Module List dialog box Lists the names and file path names of the downloaded load module files. Browse dialog box Debugger Option dialog box, Select the file to be set in Source Search dialog box. Source Text move dialog box This dialog box is used to specify a file to be displayed in Source window and the position from which displaying the file is to be started. Address move dialog box Specifies the start address to display the contents of the Memory window, or Assemble window. Symbol To Address dialog box Displays the addresses and symbol values of variables and functions. Source window Displays a source file or text file. Source Search dialog box Searches for a character string in a source file. Assemble window Disassembles the program and executes online assembly. Assemble Search dialog box Searches the contents of the Assemble window. Memory window Displays and modifies the contents of memory. Memory Search dialog box Searches the contents of the Memory window. Memory Fill dialog box Initializes the memory contents with specified data. Memory Copy dialog box Copies the memory. User’s Manual U16525EJ1V0UM 41 CHAPTER 7 WINDOW REFERENCE Table 7-1 Window List Window Name 7.2 42 Contents Memory Compare dialog box Compares the memory. Memory Compare Result dialog box Displays the result of comparing the memory. DMM dialog box Sets addresses and data subject to DMM. Watch window Displays and modifies variables. Quick Watch dialog box Temporarily displays and changes the value of a variable. Add Watch dialog box Registers a variable to be displayed in the Watch window. Change Watch dialog box Changes a variable to be displayed in the Watch window. Local Variable window Displays and changes the local variable in the current function. Stack Trace window Displays and changes the stack contents of the current user program. Register window Displays and changes the contents of the registers (program registers and system registers). Register Select dialog box Selects a register to be displayed in the Register window. IOR window Displays and changes the contents of the peripheral I/O registers. IOR Select dialog box Selects a peripheral I/O register or I/O port to be displayed in the IOR window. Add I/O Port dialog box Registers an I/O port to be displayed in the IOR window. Event Manager Displays, enables/disables, and deletes each event condition. Event dialog box Registers and displays event conditions. Event Link dialog box Registers and displays event link conditions. Break dialog box Registers, sets, and displays break event conditions. Software Break Manager Display, enable or disable, and delete software breaks. Reset Debugger dialog box Initializes the ID850NWC, target CPU, and symbol information. About dialog box Displays the version of the ID850NWC. Exit Debugger dialog box Terminate the ID850NWC. Console window Inputs commands. Error/Warning dialog box Displays error/warning messages. This section explains each debug window as follows: User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Window name Briefly explains the function of the window or dialog box and points to be noted. In addition, the display image of the window or dialog box is also illustrated. Items of related operation are also explained. Opening Explains how to open the window or dialog box. If two or more methods of opening are listed, the window or dialog box can be opened by any of them. Explanation of each area Explains items to be set to or displayed in each area of the window or dialog box. Functions often used (right-click menu) Explains the context menu that is displayed in the window when the right mouse button is clicked. From the context menu, convenient functions often used in this window can be selected with a single action (window only). Function buttons Explains the operation of each button in the window or dialog box. Related operations Explains the operation of a window or dialog box related to this window or dialog box. User’s Manual U16525EJ1V0UM 43 CHAPTER 7 WINDOW REFERENCE Main window This window is automatically opened when the ID850NWC is started up and initialized. It exists on the screen until the ID850NWC is terminated. Other windows are manipulated from this window. Execution of the user program is controlled in this window. Execution of the user program is controlled in the following three modes: Source mode Debugs the user program at the source level. Instruction mode Debugs the user program at the instruction level. Auto mode Automatically selects the source mode or instruction mode. The auto mode is set when the debugger is started up. Figure 7-1 Main Window This section explains the following items: • Toolbar • Menu bar • Window display area • Status bar Toolbar The toolbar is a collection of buttons that can execute often-used commands with a single action. Each button is graphically displayed to indicate the image of its function. This toolbar can be displayed in the following two modes. The modes are selected in Debugger Option dialog box. 44 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Figure 7-2 Toolbar with Only Graphics (default) Figure 7-3 Toolbar with Graphics and Characters Whether the toolbar is displayed or not can be specified by selecting [Option] -> [Tool Bar] from the menu bar. This toolbar can be moved inside or outside the main window by dragging and dropping with the mouse. The meaning of each button on the toolbar is as follows. When the mouse cursor is placed on a button of the toolbar, a tool hint pops up several seconds later. Stop ReGo Go Go Ret Step Over Stops execution of the user program. Same function as [Run] -> [Stop] on the menu bar. Resets the CPU and executes the user program. Same function as [Run] -> [Restart] on the menu bar. Executes the user program from the current PC without resetting the CPU. Same function as [Run] -> [Go] on the menu bar. Executes the user program without a break occurrence. Same function as [Run] -> [Ignore break points and Go] on the menu bar. The user program is real-time executed until execution returns. Same function as [Run] -> [Return Out] on the menu bar * This command is used for a function described in C language. Step execution (executes instructions in the program one by one.) If a function or subroutine is called, its instructions are executed one by one. Same function as [Run] -> [Step In] on the menu bar. Next step execution (executes the program, assuming a function/call statement as one step.) If a function or subroutine is called, its instructions are not executed on a step-by-step basis. Same function as [Run] -> [Next Over] on the menu bar. Res Resets the CPU. Same function as [Run] -> [CPU Reset] on the menu bar. Open Opens View File Load dialog box. Same function as [File] -> [Open...] on the menu bar. Load Opens Download dialog box. Same function as [File] -> [Download...] on the menu bar. Proj Opens Project File Load dialog box. Same function as [File] -> [Project] -> [Open...] on the menu bar. User’s Manual U16525EJ1V0UM 45 CHAPTER 7 WINDOW REFERENCE Src Displays the source text. Opens Source window. Same function as [Browse] -> [Source Text] on the menu bar. Asm Displays the disassemble results. Opens Assemble window. Same function as [Browse] -> [Assemble] on the menu bar. Mem Displays the contents of the memory. Opens Memory window. Same function as [Browse] -> [Memory] on the menu bar. Wch Displays the watch contents. Opens Watch window. Same function as [Browse] -> [Watch] on the menu bar. Reg Displays the register contents. Opens Register window. Same function as [Browse] -> [Register] on the menu bar. IOR Displays the contents of the Peripheral I/O registers. Opens IOR window. Same function as [Browse] -> [I/O Register] on the menu bar. Loc Displays the local variable contents. Opens Local Variable window. Same function as [Browse] -> [Local Variable] on the menu bar. Stk Displays the stack contents. Opens Stack Trace window. Same function as [Browse] -> [Stack Trace] on the menu bar. Cannot be selected. TrW Mgr Opens Event Manager. Same function as [Event] -> [Event Manager] on the menu bar. Evn Registers and sets events. Opens Event dialog box. Same function as [Event] -> [Event...] on the menu bar. Brk Registers and sets break events. Opens Break dialog box. Same function as [Event] -> [Break...] on the menu bar. Cannot be selected. Trc 46 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Menu bar The menu bar consists of the following menus: (2) [Edit] menu (3) [View] menu (4) [Option] menu (5) [Run] menu (6) [Event] menu (7) [Browse] menu (8) [Jump] menu (9) [Window] menu (10) [Help] menu (1) [File] menu (1) [File] menu Open... Loads a view file, source file, or text file. Opens View File Load dialog box. The operation differs depending on the extension of the file selected in the dialog box. Save As... Saves the contents displayed on the current window to the file whose name is specified. Opens View File Save dialog box. Close Closes the current window. Download... Downloads a program. Opens Download dialog box. Load Module... Lists the names of the files that have been downloaded. Opens Load Module List dialog box. Upload... Uploads a program. Opens Upload dialog box. Project Manipulates a project file. User’s Manual U16525EJ1V0UM 47 CHAPTER 7 WINDOW REFERENCE (2) Open... Opens a project file. Opens Project File Load dialog box. Save Overwrites the current status to the project file currently being read to the ID850NWC. Save As... Saves the current status to a specified project file. Opens Project File Save dialog box. Debugger Reset... Initializes the CPU, symbols, and ID850NWC. Opens Reset Debugger dialog box. Exit Terminates the ID850NWC. Opens Exit Debugger dialog box. (Open file) Lists the names of the files opened. [Edit] menu Cut Cuts a selected character string and saves it to the clipboard buffer. Copy Copies a selected character string and saves it to the clipboard buffer. Paste Pastes the contents of the clipboard buffer to the text cursor position. Write in Writes the modified contents to the target. Restore Cancels the modification. Memory Manipulates the memory contents. Fill... Initializes the memory. Opens Memory Fill dialog box. Copy... Copies the memory. Opens Memory Copy dialog box. Compare... Compares the memory. Opens Memory Compare dialog box. Modify... Rewrites the memory contents during user program execution. Opens DMM dialog box. Edit Source 48 Opens the source file displayed in the active Source window with the editor specified by the PM plus when the PM plus runs. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (3) [View] menu This menu displays different items depending on the window that is active. The following items may be displayed: • Common items • Source window-dedicated items • Assemble window-dedicated items • Memory window-dedicated items • Watch window-dedicated items • Register window-dedicated items • IOR window-dedicated items • Local Variable window-dedicated items, Stack Trace window-dedicated items • Event Manager-dedicated items Common items Search... Performs a search. Opens the search dialog box corresponding to the current window. Same operation as the <Search> button. Move... Moves the display position. Opens the specification dialog box corresponding to the current window. Quick Watch... Temporarily displays the contents of the specified data. Opens Quick Watch dialog box. Add Watch... Registers the specified data to the Watch window. Opens Add Watch dialog box. View Watch Adds the selected data to the Watch window. If the data is a symbol, it is added in accordance with the setting of Debugger Option dialog box. Change Watch... Changes the data on the line selected by the Watch window. Opens Change Watch dialog box. This menu is valid only when a variable is selected in Watch window. Delete Watch Deletes the selected watch point from the Watch window. This menu is valid only when a variable is selected in Watch window. Symbol... Displays the address of the specified variable or function, or the value of the specified symbol. Opens Symbol To Address dialog box. User’s Manual U16525EJ1V0UM 49 CHAPTER 7 WINDOW REFERENCE Source window-dedicated items Create Break Event Creates a break event by using the selected variable. Break when Access to this Variable Creates a break event that can be accessed for read/write. Break when Write to this Variable Creates a break event that can be accessed for write. Break when Read from this Variable Creates a break event that can be accessed for read. Clear Deletes a break event corresponding to the selected variable. Event? Displays the event information of a line at the cursor position or a selected variable name. If an event is set, Event dialog box is opened. Mix Specifies whether the results of assembly are displayed in mixed display mode, or not displayed. Checked: Mixed display Not checked: No display (default) Assemble window-dedicated items Event? Displays the event information of the address at the cursor position. If an event is set, Event dialog box is opened. Memory window-dedicated items 50 Bin Displays binary numbers. Oct Displays octal numbers. Dec Displays decimal numbers. Hex Displays hexadecimal numbers (default). Nibble Displays in 4-bit units. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Byte Displays in 8-bit units (default). Half Word Displays in 16-bit units. Word Displays in 32-bit units. Ascii Selects whether ASCII characters are displayed or not. Checked: Displayed Not checked: No display (default) Little Endian Displays in little endian (default). Big Endian Displays in big endian. Watch window-dedicated items Only "selected items" can be manipulated in the Watch window. Create Break Event Creates a break event by using the selected item. Break when Access to this Variable Creates a break event that can be accessed for read/write. Break when Write to this Variable Creates a break event that can be accessed for write. Break when Read from this Variable Creates a break event that can be accessed for read. Clear Deletes a break event corresponding to the selected item. Event? Displays the event information of the variable selected. If an event is set, Event dialog box is opened. Bin Displays binary numbers. Oct Displays octal numbers. Dec Displays decimal numbers. Hex Displays octal numbers. String Displays character strings. Proper Displays the default value of each variable. Symbols are displayed in accordance with the setting of Debugger Option dialog box (default). Byte Displays in 8-bit units. User’s Manual U16525EJ1V0UM 51 CHAPTER 7 WINDOW REFERENCE Half Word Displays in 16-bit units. Word Displays in 32-bit units. Adaptive Displays the default value of each variable. Only this item is valid for a symbol in C language. Symbols are displayed in accordance with the setting of Debugger Option dialog box (default). Up Moves up one line. Down Moves down one line. Compulsion Read Forcibly reads the peripheral I/O registers that are disabled from being read because their values will be changed, or the data of the I/O ports and I/O protect area added in Add I/O Port dialog box. Register window-dedicated items Bin Displays binary numbers. Oct Displays octal numbers. Dec Displays decimal numbers. Hex Displays hexadecimal numbers (default). Pick Up Displays only the registers selected in Register Select dialog box. Checked: Displays only the selected register. Not checked: Displays all the registers (default). Select... Opens Register Select dialog box. IOR window-dedicated items 52 Bin Displays binary numbers. Oct Displays octal numbers. Dec Displays decimal numbers. Hex Displays hexadecimal numbers (default). User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Sort By Name Displays in alphabetical order. Sort By Address Displays in address order (default). Unsort Does not sort. Attribute Displays or does not display an attribute field (Attribute). Checked: Displayed (default) Not checked: Not displayed Pick Up Displays only the registers selected in IOR Select dialog box. Checked: Displays only the selected register. Not checked: Displays all the registers (default). Select... Opens IOR Select dialog box. Compulsion Read Forcibly reads the peripheral I/O registers that are disabled from being read because their values will be changed, or the data of the I/O ports and I/O protect area added in Add I/O Port dialog box. Local Variable window-dedicated items, Stack Trace window-dedicated items Bin Displays binary numbers. Oct Displays octal numbers. Dec Displays decimal numbers. Hex Displays octal numbers. String Displays character strings. Proper Displays the default value of each variable (default). Event Manager-dedicated items Select All Event Selects all the events registered to the Event Manager. Delete Event Deletes a selected event. Sort By Name Displays icons in the order of event names. Sort By Kind Displays icons in the order of event types. Unsort Does not sort icons (default). Detail Detailed display User’s Manual U16525EJ1V0UM 53 CHAPTER 7 WINDOW REFERENCE Overview (4) 54 List display (default) [Option] menu Tool Bar Selects whether the tool bar is displayed (default) or not. Status Bar Selects whether the status bar is displayed (default) or not. Button Selects whether the buttons on each window are displayed (default) or not. Source Mode Executes step execution at the source level (in line units). Instruction Mode Executes step execution at the instruction level (in instruction units). Auto Mode Automatically selects step execution at the source level or step execution at the instruction level (default). Step execution is performed at the source level (in a mode other than mixed display mode) if Source window is active. It is performed at the instruction level if Assemble window is active. If neither window is active, step execution is performed at the source level. Configuration... Sets the environment. Opens Configuration dialog box. Extended Option... Sets extended functions. Opens Extended Option dialog box. Debugger Option... Sets debugger options. Opens Debugger Option dialog box. Add I/O Port... Adds user-defined I/O ports. Opens Add I/O Port dialog box. Trace Cannot be selected. Tracer ON Cannot be selected. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (5) [Run] menu Restart Resets the CPU and executes the program. Same operation as the ReGo button Stop Forcibly stops program execution. Same operation as the Stop button Go Executes the program from the current PC. Same operation as the Go button Ignore break points and Go Executes the program, ignoring break points being set. Same operation as the GoN button Return Out The user program is real-time executed until execution returns. Same operation as the Ret button Note: This menu item is available only for a function described in C language. Step In Executes the instructions in the program one by one (step execution). If a function or subroutine is called, its instructions are executed one by one. Same operation as the Step button Next Over Executes the instructions in the program one by one (Next step execution). If a function or subroutine is called, its instructions are not executed on a step-by-step basis. Same operation as the Over button Start From Here Executes the program from the cursor position on Source window or Assemble window. Come Here Executes the program from the current PC to the cursor position in the Source window or Assemble window. Go & Go Continues executing the program. If a break occurs because a break condition is satisfied, the window is updated and the program is executed again. Each time a break has occurred, the same operation as clicking the Go button is performed. User’s Manual U16525EJ1V0UM 55 CHAPTER 7 WINDOW REFERENCE (6) 56 Slowmotion Continues step execution. Each time step execution has been performed, the window is updated and then step execution is performed again. Same operation as clicking the Step each time a break has occurred. CPU Reset Resets the CPU. Same operation as the Res button Change PC Sets the address at the cursor position in the Source window or Assemble window to the PC. Break Point Sets or cancels a breakpoint at the cursor position in the Source window or Assemble window. Software BreakPoint Sets or cancels a software breakpoint at the cursor position in the Source window or Assemble window. Delete All Breakpoints Deletes all software breakpoints that are set. Uncond. Trace ON Cannot be selected. Cond. Trace ON Cannot be selected. Tracer Control Mode Cannot be selected. Tracer Start/ Tracer Stop Cannot be selected. [Event] menu Event Manager Manages various event conditions. Opens Event Manager. Same operation as the Mgr button Software Break Manager Manages software break event conditions. Opens the Software Break Manager. Event... Registers an event condition. Opens Event dialog box. Same operation as the Evn button Event Link... Registers an event link condition. Opens Event Link dialog box. Break... Registers and sets a break condition. Opens Break dialog box. Same operation as the Brk button Trace... Cannot be selected. Delay Count... Cannot be selected. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (7) [Browse] menu Source Text Displays a source text. Opens Source window. Same operation as the Src button If there is a Source Text window already open in the active status, it is opened in the static status. Assemble Displays the disassemble results. Opens Assemble window. Same operation as the Asm button If there is a Assemble window already open in the active status, it is opened in the static status. Memory Displays the contents of the memory. Opens Memory window. Same operation as the Mem button If there is a Memory window already open in the active status, it is opened in the static status. Watch Displays the watch contents. Opens Watch window. Same operation as the Wch button Register Displays the register contents. Opens Register window. Same operation as the Reg button I/O Register Displays the contents of the Peripheral I/O registers. Opens IOR window. Same operation as the IOR button Local Variable Displays the local variable. Opens Local Variable window. Same operation as the Loc button Stack Trace Displays the stack trace results. Opens Stack Trace window. Same operation as the Stk button Trace Cannot be selected. Console Opens Console window. Others Displays other windows. Displays a user-defined window list. User’s Manual U16525EJ1V0UM 57 CHAPTER 7 WINDOW REFERENCE (8) (9) 58 [Jump] menu Source Text Displays the corresponding source text and source line, using the data value selected in the current window as the jump destination address. If no line information is at the jump destination address, however, you cannot jump. Opens Source window. If an active Source window is open, that window is displayed in the forefront (so that it can be manipulated). Assemble Disassembles and displays the results from the jump destination address specified by the data value selected in the current window. Opens Assemble window. If an active Assemble window is open, that window is displayed in the forefront (so that it can be manipulated). Memory Displays the memory contents from the jump destination address specified by the data value selected in the current window. Opens Memory window. If an active Memory windowis open, that window is displayed in the forefront (so that it can be manipulated). [Window] menu New Window Opens a new window displaying the same contents as those of the current window. This menu is valid only when the current window is Source window, Assemble window, or Memory window. Cascade Cascade display of the windows in the Main window. Tile Tile display of the windows in the Main window. Arrange Icons Rearranges the icons in the Main window. Close All Closes all windows, except the Main window. Refresh Updates the contents of the window with the latest data. Active Sets the window in the active status. If the window is already in the active status, a check mark is shown on the left of this item. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Static Sets the window in the static status. If the window is already in the static status, a check mark is shown on the left of this item. (Open Window) Lists the windows that are open. The window with the check mark shown on the side of the figure is the current window. By selecting a window name, the selected window is used as the current window. (10) [Help] menu ID850NWC Help Displays the help of ID850NWC. Command Reference Opens the Help window of COMMAND REFERENCE. Main Window Help Displays the help of the Main window. Current Window Help Displays the help of the current window. About... Displays the version of the ID850NWC. Opens About dialog box. Window display area This area (at the center) displays various debug windows. The displayed window can be changed in size or an icon can be created in this area. Status bar The status bar is displayed at the bottom of the window and indicates the status of the ID850NWC and incircuit emulator. While the user program is being executed, the status bar is displayed in red. Whether the status bar is displayed or not can be selected by selecting [Option] -> [Status Bar] from the menu bar. Figure 7-4 Status Bar User’s Manual U16525EJ1V0UM 59 CHAPTER 7 WINDOW REFERENCE (1) Program name Displays the program file name indicated by the PC value. Source name Displays the source file name indicated by the PC value. Line number Displays the line number indicated by the PC value. (2) Function name Displays the function name indicated by the PC value. (3) PC value Displays the current PC value. (4) CPU status Displays the status of the CPU (target device). RESET...Reset status POW OFF...Power is not supplied to the target. HOLD...Bus hold HALT...Halt mode WAIT...Wait mode STOP/IDLE...Software stop mode, hardware stop mode, or idle (5) IE status Displays the status of the in-circuit emulator. (If there are two or more the statuses, they delimited with '|' and displayed.) RUN...User program execution in progress (the color of the status bar changes). STEP...Step execution in progress BREAK...Break occurring. Time...Displays the result of measuring the time from the start of user program execution to the occurrence of break (Run-Break time) (measurable range: 100 ns to 214 seconds). TIMER OVERFLOW...Measurement result overflowed. Caution:Time and TIMER OVERFLOW are displayed only with a CPU core that includes RCU1. (6) Break Cause Displays Table 7-2 Break Cause. (7) STEP mode Displays the step execution mode. Displays that the following modes are selected from the [Option] menu: SRC...Source mode INST...Instruction mode AUTO...Automatic mode (8) Key input mode Displays the key input mode. INS... Insertion mode OVR...Overwrite mode The Memory window is fixed to OVR mode. Table 7-2 Break Cause Display 60 Meaning Manual Break Forced break Temporary Break Temporary break Event Break Break by event Software Break Software break Flash Macro Service Under flash macro service User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Table 7-2 Break Cause Display Ffa01: The line information on PC position not found. Meaning The source file corresponding to program counter (PC) value when the program was stopped could not be found. The following reasons are possible. 1) The source file exists in a location that the source path does not connect to. 2) The program stopped where the source files, such as library or RX, do not exist. 3) The program looped, jumped to an address that is not used by the program, and stopped there. User’s Manual U16525EJ1V0UM 61 CHAPTER 7 WINDOW REFERENCE Configuration dialog box Displays and sets the ID850NWC operation environment. This dialog box is automatically displayed after the ID850NWC is started up. To use the ID850NWC, the operating environment of the ID850NWC and in-circuit emulator must be first set in this dialog box. However, no setting is required to read a project as the results of reading the project file are reflected in this dialog box. For details of the mapping function, refer to "Mapping Function". Figure 7-5 Configuration Dialog Box This section explains the following items: • Opening • Explanation of each area • Setting of memory mapping • Function buttons • Related operations • To change the value of a register required for access of an external memory 62 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Opening This dialog box can be opened as follows: • Automatically when the ID850NWC is started up • Select [Option] -> [Configuration...] from the menu bar. (Or press Alt, O, and C in that order) Explanation of each area The Configuration dialog box consists of the following areas: (2) Internal ROM/RAM (internal ROM/RAM setting area) (3) Programmable I/O Area (programmable I/O area address setting area) (4) Clock (CPU clock source selection area) (5) ID Code (ID code input area) (6) Peripheral Break (break mode selection area) (7) Monitor Clock (monitor operation clock selection area) (8) Mask (mask setting area) (9) Memory Mapping (mapping setting area) (1) Chip (CPU selection area) (1) Chip (CPU selection area) This area is used to select the chip name. A chip name is selected from the drop-down list.On the drop-down list, Only the chip names registered to the registry from the DF installer are displayed. This area can be specified only when the debugger is started up. The chip name selected at the previous start-up is displayed by default. (2) Internal ROM/RAM (internal ROM/RAM setting area) This area is used to display the size of the internal RAM and internal ROM of the CPU. The internal ROM and RAM sizes cannot be changed. The default size is automatically displayed with the asterisk (*) attached at the end when a chip is selected. User’s Manual U16525EJ1V0UM 63 CHAPTER 7 WINDOW REFERENCE (3) Programmable I/O Area (programmable I/O area address setting area) This area is used to specify usage of the programmable I/O area and the start address. The start address of the programmable I/O area can be input by checking the check box when the programmable I/O area is used, only if the device selected by Chip supports the programmable I/O area. The address is aligned to 16 KB. If the device selected by Chip has an expansion I/O area of fixed addresses, this area is automatically set. (4) Clock (CPU clock source selection area) This area is used to select the frequencies of the CPU operation main clock (fX) and subclock (fTx). The frequencies set in this area are used for WAIT calculation for JTAG communication. (5) Main OSC Specifies a frequency before the main clock is multiplied. A frequency can be selected from the drop-down list (5.000, 8.000, 13.500, or 18.000) or input from the keyboard. Sub Specifies the frequency of the subclock (this cannot be set if the device selected by Chip does not have a subclock). A frequency can be selected from the drop-down list or input from the keyboard. ID Code (ID code input area) This area is used to input the ID code to be used when the code on the internal ROM or internal flash memory is read (ID code authentication). Input a hexadecimal number of 20 digits (10 bytes) as the ID code (all 'F' by default). The ID code is saved to the registry. If inputting the ID code fails three times, the ID850NWC is forcibly terminated. This area does not have to be set with a ROMless product or a product without a security unit. For the details of ID code authentication, refer to "IE-V850E1-CD-NWUser's Manual". 64 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (6) Peripheral Break (break mode selection area) This area is used to specify whether the peripheral I/O function is stopped during a break. (7) Break Stopped Non Break Not stopped (default) Monitor Clock (monitor operation clock selection area) This area is used to specify whether the operation clock of the monitor program is switched from the subclock to the main clock during a break. This area does not have to be set with a product without a subclock. (8) System The operation clock is switched to the main clock and the monitor program is executed (default). Caution :In theID850NWC, the clock is changed by manipulating PCC, but not while the main clock is stopped. If the operation clock is switched to the main clock during a break, the clock is returned to the previous setting when execution returns to the user program. User The monitor program is executed with the clock selected by the user program. Mask (mask setting area) This area is used to mask the signal sent from the target . The signal of a masked pin is not input to the in-circuit emulator and CPU. Mask a pin only when the operation of the target is not stable at the debugging stage. By checking RESET, the external reset or internal reset generated by the watchdog timer can be masked. At this time, whether internal reset can be masked or not depends on the device. User’s Manual U16525EJ1V0UM 65 CHAPTER 7 WINDOW REFERENCE (9) Memory Mapping (mapping setting area) This area is used to set mapping by specifying the access size, memory attribute, and address. Access Size (selection of memory access size) Selects memory access size. This setting is used to specify the access size on the ID850NWC software; the operation of the external bus hardware is set in accordance with the settings of the MODE pin and I/O register. 8Bit Accesses memory with ld.b instruction/st.b instruction (default). 16Bit Accesses memory with ld.h instruction/st.h instruction. 32Bit Accesses memory with ld.w instruction/st.w instruction. Memory Attribute (mapping attribute specification) The following mapping attributes can be selected. Select a mapping attribute according to the usage(refer to "Mapping Function"). Target Selects the target memory. I/O Protect Selects the I/O protect area. This area can be set only in the area set as Target. Caution The area set as I/O Protect is not read unless it is registered to the IOR window a or Watch window as an I/O port. To read this area, forcibly read it on these windows. Mapping Address (mapping address specification) Specify the address to be mapped. Input the higher and lower addresses from the keyboard. Setting of memory mapping Specify Memory Attribute and Mapping Address and then click the <Add> button. -The attribute of >Memory Attribute, address range of Memory Mapping, and memory mapping corresponding to the data of the bus width are set and displayed on a list. A mapping attribute other than I/O Protect, a mapping attribute is adjusted in mapping units when the <Add> button is clicked. If the mapping unit does not match, the minimum settable range including the specified address is mapped. The mapping unit is as follows: 66 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Table 7-3 Mapping Unit in Configuration Dialog Box Mapping Area Mapping Unit I/O Protect 1-byte unit Target 1Mbyte units Caution If the external memory is mapped, change the value of a register required for access of an external memory.(refer to "To change the value of a register required for access of an external memory"). Deleting memory mapping Select mapping to be deleted from the list and click the <Delete> button. -> This deletes the selected mapping. Function buttons OK Validates the current environment. Sets the environment and closes this dialog box. Cancel Cancels the changes and closes this dialog box. Restore Restores the previous environment settings status before this dialog box was opened. Project Opens the Project File Load dialog box. If an error occurs while a project file is being opened or read, the ID850NWC can no longer continue and is terminated. Help Opens the Help window. Related operations To change the value of a register required for access of an external memory When mapping has been performed for external memory, change the values of the registers required for accessing external memory prior to downloading, using IOR window or the hook procedure. For how to change register values using the hook procedure, refer to "Hook Procedure" in COMMAND REFERENCE. For the registers to be changed, refer to the hardware manual of the CPU that is used. User’s Manual U16525EJ1V0UM 67 CHAPTER 7 WINDOW REFERENCE Extended Option dialog box This dialog box is used to display and set the extended options of the ID850NWC. Figure 7-6 Extended Option Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [Option] ->[Extended Option...] from the menu bar. (Or press Alt, O, and X in that order) Explanation of each area The Extended Option dialog box consists of the following areas: (2) RAM Monitor (RAM monitor setting area) (3) On Mouse Click (default break selection area) (4) Break Sound (beep sound specification area) (5) Verify Check (verify specification area) (1) Trace Memory Size (trace memory size setting area) 68 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Trace Memory Size (trace memory size setting area) This area does not have to be set. (2) RAM Monitor (RAM monitor setting area) Function (Select RAM Sampling function) This area selects the RAM sampling function as valid/invalid. Since this function is realized by software emulation, the user program execution is temporarily stopped. On Enables this function. All the break events already set become invalid. Off Disables this function (default). Area (Whole RAM sampling range specification) Specify the address range in RAM sampling is to be performed. The variables and data allocated to this area can be displayed in Watch window , Memory window and IOR window. Whole The entire memory space is the target. The user program execution is stopped for a long time when a large number of windows are opened because the range from which memory is read out is wid. IRAM+IOR Only the internal RAM area and the peripheral I/O register area are the target (default). Redraw Interval ( RAM sampling time specification) Specify the sampling time (ms) of the RAM sampling. The RAM area can be sampled during emulation. Variables, data, etc., allocated to the RAM area can be displayed in the Watch window, Memory window, or IOR window. The sampling time can be specified in 100-ms units from 0 to 65500. Display is not performed if 0 or nothing is specified. User’s Manual U16525EJ1V0UM 69 CHAPTER 7 WINDOW REFERENCE (3) On Mouse Click (default break selection area) This area is used to select whether a software breakpoint or hardware breakpoint is set as the default breakpoint if a breakpoint is set in the point mark area by clicking the mouse button in the Source window or Assemble window. (4) Soft break Sets a software breakpoint (default). The mark of breakpoint is displayed in blue. Hard break Sets a hardware breakpoint. The mark of breakpoint is displayed in red. Break Sound (beep sound specification area) This area is used to specify whether a beep sound is issued upon the occurrence of a break. If the check box is checked, a beep sound is issued when a break occurs (default). (5) Verify Check (verify specification area) This area is used to specify whether a verify check is performed when data has been written to memory. If the check box is checked, a verify check is performed when download, memory fill, or memory copy is executed (default). A verify check is also performed when a variable or data is changed in Watch window or Memory window and is written to memory. When they are written to the internal flash memory(including downloading), an internal verify is performed regardless of check in this area(but read verify is not performed). Function buttons 70 OK Validates the settings and closes this dialog box. Cancel Cancels the settings and closes this dialog box. Restore Restores the previous settings before this dialog box was opened. Help Opens the Help window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Debugger Option dialog box This dialog box is used to display and set the various options of the ID850NWC. Figure 7-7 Debugger Option Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [Option] -> [Debugger Option...] from the menu bar (or press Alt+O, and G in that order). Explanation of each area The Debugger Option dialog box consists of the following areas: (2) Default Extension (default extension specification area) (3) Open File History (open file history setting area) (1) Source Path (source path specification area) User’s Manual U16525EJ1V0UM 71 CHAPTER 7 WINDOW REFERENCE (5) Project File (project file setting area) (6) Tool Bar Pictures (toolbar display button setting area) (7) Kanji (Kanji code setting area) (8) Tab Size (tab size setting area) (9) Startup Routine (start-up symbol setting area) (10) DisAssemble (offset display setting area) (11) Watch Default (watch symbol setting area) (4) Font (display font setting area) (1) Source Path (source path specification area) This area is used to specify the directory in which a source file or text file is searched. A path can be input from the keyboard or set by the <Browse...> button. A relative path can also be specified. The directory that is the basis of a relative path is displayed on the right of Base:. The base directory is determined in the following sequence: • Directory to which the project file has been loaded • Directory to which a load module or hex file has been loaded last • Current directory of Windows To delimit paths, use ";" (semicolon) or "," (comma). Example: If a source is in the following directory C:\src C:\asm The source path is specified as follows: C:\src; C:\asm Clicking the <Browse...> button displays the Add Source path Dialog Box and a source path can be added. Reference Immediately after the Debugger Option dialog box has been opened, the base directory is selected and opened If the selected directory has already been set for the source path, a source path is not added. 72 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Figure 7-8 Add Source path Dialog Box (2) Default Extension (default extension specification area) Delimit extensions with " " (blank),";" (semicolon) or "," (comma). (3) Source File Set the extension of a source file that is displayed when the Browse dialog box is opened by selecting [File] -> [Open...] from the menu bar. The default extension is "*.C, *.S". Load Module Set the extension of a load module that is displayed when Download dialog box is opened. The default extension is "*.OUT". Open File History (open file history setting area) This area is used to set the number of histories (0 to 10) of the open file displayed in the bottom field of the [File] menu. If 0 is set, no history is displayed on the menu. The default value is 4. (4) Font (display font setting area) This area is used to specify the font displayed on the Source window. Clicking the <Font...> button opens the Font dialog box in which the font to be displayed and its size can be set. User’s Manual U16525EJ1V0UM 73 CHAPTER 7 WINDOW REFERENCE (5) Project File (project file setting area) This area is used to set automatic saving and loading of the project file. Auto save Sets whether the project file is automatically saved at the ID850NWC termination. On Automatically saves the project file at the ID850NWC termination. Off Does not automatically save the project file at the ID850NWC termination. Query Displays the Exit Debugger dialog box at the ID850NWC termination (default). Auto Load Sets whether the project file is automatically loaded at the ID850NWC start up. On Automatically loads the project file at the ID850NWC start up. Sets whether the Load Project File is automatically loaded Off Does not automatically loads the project file at the ID850NWC start up(default). Load Project File Specify the project file to be loaded automatically. This item can be specified only when On is specified for Auto Load. Set a project file name by inputting from the keyboard or clicking the <Browse...> button. Clicking the <Browse...> button displays Browse dialog box. (6) Tool Bar Pictures (toolbar display button setting area) This area sets the buttons to be displayed on the toolbar. 74 Pictures and Text Displays a button on which a graphic and character are displayed. Pictures only Displays a button with only graphic (default). User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (7) Kanji (Kanji code setting area) This area is used to specify Kanji codes to be displayed in the Source window. Kanji codes can be specified only on the Japanese Windows. (8) Sjis Uses SJIS as Kanji codes (default). Euc Uses EUC as Kanji codes. Tab Size (tab size setting area) This area is used to set the tab size for each extension when files are displayed. Extension Set an extension. Input an extension from the keyboard, or select one from the drop-down list. Tab Size Select the tab size. Select how many spaces are displayed as a tab code. 2 Displays two spaces. 4 Displays four spaces. 8 Displays eight spaces. Tab List Displays the tab size set for each extension. To change the tab size setting, select Extension and Tab Size and click the <Add> button. To delete the tab size setting, select the setting to be deleted from Tab List and click <Delete> button. (9) Startup Routine (start-up symbol setting area) This area is used to specify the first address and end address of the text area (code area) of the startup routine by symbols. Specify the symbol of the first address as Begin label, and the symbol of the last address as End label. User’s Manual U16525EJ1V0UM 75 CHAPTER 7 WINDOW REFERENCE In this way, the source file can be automatically opened if an object file in the load module format is downloaded in Download dialog box. Specify the source file to be displayed at this time as main( ) label, as a display start symbol. If the specified symbol is not correct, the source file cannot be opened until the PC reaches the address range of the corresponding source file. In addition, the start-up routine cannot be skipped by step execution. Begin label Symbol of first address (default: _start) End label Symbol of end address (default: _startend) main() label Display start symbol (default: _main) Caution Be sure to specify this area. If this area is blank, the dialog box cannot be closed. (10) DisAssemble (offset display setting area) Performs the setting for disassemble display. Show Offset Specifies whether an offset (symbol + offset) is displayed during disassemble display. When the offset is not displayed, only a symbol that matches a numeric value is displayed, if any. If no matching symbol is found, the numeric value is displayed as a hexadecimal number unchanged. Label Specifies whether the offset is displayed in the Label field. This check box is not checked in the default condition, and the offset is not displayed. Mnemonic Specifies whether the offset is displayed in the Mnemonic field. This check box is checked in the default condition, and the offset is displayed. Register Name (register name display selection area) This area is used to select the method of displaying register names in mnemonics during disassemble display. Function Name Displays register names as function names or nicknames (default). Absolute Name Displays register names as absolute names. (11) Watch Default (watch symbol setting area) This area is used to specify a symbol to be watched. 76 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Size (default size specification) Sets the display size of data if [Adaptive] is selected in Watch window etc. Byte 8-bit display(default) Half Word 16-bit display Word 32-bit display Radix (default radix specification) Sets the default radix in which data is to be displayed if [Proper] is specified in Watch window etc. Hex Displays data in hexadecimal numbers (default). Dec Displays data in decimal numbers. Oct Displays data in octal numbers. Bin Displays data in binary numbers. String Character string Show Variable Type (display/non-display of variable type) Select the display/non-display of variable type is specified in Watch window etc. On Displays the type of a variable. Off Does not display the type of a variable (default). Language (display/non-display of type of variable) Select the display/non-display of type of variable is specified in Watch window etc. With the ID850NWC, the display format is fixed to C-like and cannot be selected. C Displays a C-like base number (default). ASM Cannot be selected. Function buttons OK Validates the settings and closes this dialog box. Cancel Cancels the settings and closes this dialog box. Restore Restores the previous settings before this dialog box was opened. Help Opens the Help window. User’s Manual U16525EJ1V0UM 77 CHAPTER 7 WINDOW REFERENCE Font dialog box This dialog box is used to select the font to be displayed in the Source window. Figure 7-9 Font Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Click the <Font> button in Debugger Option dialog box. Explanation of each area The Font dialog box consists of the following areas: (2) Size: (font size specification area) (3) Sample (sample display area) (1) Font Face: (font name specification area) 78 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Font Face: (font name specification area) This area is used to select a font from the fonts currently usable. Only fonts with equal width (fonts with a constant stroke width and a fixed pitch) are enumerated. When a font name is selected from the list, the font name is displayed in the text box, and the font size that can be used with that font is displayed under Size. (2) Size: (font size specification area) This area is used to specify the font size (unit : pt). On the drop-down list, the font size usable for the font specified in Font Face is displayed in point units. When the font size is selected from the drop-down list, the selected font size is displayed in this area. The font size can also be directly input to the text box from the keyboard. (3) Sample (sample display area) This area displays a sample character string of the specified font and size. Function buttons OK Changes the font and its size in the Source window as specified, and closes this dialog box. Cancel Closes the dialog box without changing the font. User’s Manual U16525EJ1V0UM 79 CHAPTER 7 WINDOW REFERENCE Project File Save dialog box Saves the debug environment. It is used to save a new project file or an existing file with the file name changed (refer to "Setting Debugging Environment"). When a file is saved, the size and position of the window that has been displayed are also saved. Figure 7-10 Project File Save Dialog Box The following contents are saved to the project file: Table 7-4 Contents Saved to Project File Window Name 80 Set Data Configuration dialog box All items (target device, clock setting, pin mask setting, mapping information) Main window Display position, tool bar/status bar/button display information, execution mode information Download dialog box File information to be downloaded Extended Option dialog box, Debugger Option dialog box Set information Source window Display information, font information of window Assemble window, Memory window Display information of window, display start address User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Table 7-4 Contents Saved to Project File Window Name Set Data Stack Trace window, IOR window, Local Variable window, Event Manager, Console window, EXPANSION WINDOW Display information of window Event dialog box Display information of window, event information Event Link dialog box Display information of window, link event information Break dialog box Display information of window, break event information Register window Display information of window, display bank information Watch window Display information of window, watch registration information Add I/O Port dialog box Added I/O port information DMM dialog box DMM information Software Break Manager Display information of window, software break information This section explains the following items: • Opening • Explanation of each area • Function buttons • Related operations • To automatically save a project file Opening This dialog box can be opened as follows: • Select [File] -> [Project] -> [Save As...] from the menu bar (or press Alt+F, J and A in that order). To save a file of same name as a project file previously loaded or saved • Select [File] -> [Project] -> [Save] on the menu bar (or press Alt+F, J and S in that order). Explanation of each area The Project File Save dialog box consists of the following areas: (2) Save as type: (extension selection area) (1) Save in:, File name: (file selection area) User’s Manual U16525EJ1V0UM 81 CHAPTER 7 WINDOW REFERENCE (1) Save in:, File name: (file selection area) This area is used to specify a file name. A file name can be directly input from the keyboard, or selected from the list at the upper part of this area. Up to 64 character string with a extension can be specified. (2) Save as type: (extension selection area) This area is used to specify the extension (.PRJ) of the project file to be loaded. If the extension is omitted, .PRJ is appended as the default extension. Function buttons Save Saves the project information to the selected file. After saving, the dialog box is closed. Cancel Closes this dialog box without saving the file. Help Opens the Help window. Related operations To automatically save a project file Use Project File (project file setting area) in Debugger Option dialog box that is opened when [Option] -> [Debugger Option...] is selected from the menu bar. Select On for Auto Save in this area. The current environment will be automatically saved to the project file when the dialog box is closed. 82 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Project File Load dialog box This dialog box is used to return the debug environment to the previous environment. After a file has been loaded, the size and position of the window is returned to the previous status (status saved to a project file) (refer to "Setting Debugging Environment"). After a project file has been loaded, it is displayed on the top of an active Source window if any. By loading the project file, the items to be saved in Table 7-4 Contents Saved to Project File are set. Caution If a project file different from the target device after ID850NWC has been loaded is loaded, ID850NWC loads the project file after it has been reset (ID850NWC is then used as the target device specified by the project file). Figure 7-11 Project File Load Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons • Related operations • To automatically load a project file User’s Manual U16525EJ1V0UM 83 CHAPTER 7 WINDOW REFERENCE Opening This dialog box can be opened as follows: • Click the Proj button. • Select [File] -> [Project] -> [Open...] on the menu bar (or press Alt+F, J and O in that order). Explanation of each area The Project File Load dialog box consists of the following areas: (2) Files of type: (extension selection area) (1) Look In:, File name: (file selection area) (1) Look In:, File name: (file selection area) This area is used to specify a file name. A file name can be directly input from the keyboard, or selected from the list at the upper part of this area. Up to 64 character string with a extension can be specified. (2) Files of type: (extension selection area) This area is used to specify the extension (.PRJ) of the project file to be loaded. Function buttons Open Loads the selected file. After loading the file, this dialog box is closed. Cancel Closes this dialog box without loading the file. Help Opens the Help window. Related operations To automatically load a project file Use Project File (project file setting area) in Debugger Option dialog box that is opened when [Option] -> [Debugger Option...] is selected from the menu bar. Select On for Auto Load in this area and specify the name of the project file to be loaded automatically in the Load Project File area. The specified project file will be automatically loaded when the system is started next time. 84 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE View File Save dialog box This dialog box is used to save the contents of the current window to a view file or event setting file when a dialog box is opened. Figure 7-12 View File Save Dialog Box (Example: to Save Memory Window) This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • When the window to be saved is the current window Select [File] -> [Save As...] from the menu bar (or press Alt+F and A in that order). User’s Manual U16525EJ1V0UM 85 CHAPTER 7 WINDOW REFERENCE Explanation of each area This dialog box consists of the following areas: (2) Save as type: (extension selection area) (3) Save range (save range setting area) (1) Save in:, File name: (file selection area) (1) Save in:, File name: (file selection area) This area is used to specify a file name. A file name can be directly input from the keyboard, or selected from the list at the upper part of this area. (2) Save as type: (extension selection area) This area is used to specify the type (extension) of the file. The extension of the file corresponding to the current window is displayed as follows: Table 7-5 Extension Corresponding to Current Window File Type (Extension) (3) Current Window Name Source Text (*.SVW) Source window Assemble (*.DIS) Assemble window Memory (*.MEM) Memory window Watch(*.WCH) Watch window Register (*RGW) Register window I/O Register (*.IOR) IOR window Local Variable (*.LOC) Local Variable window Stack Trace (*.STK) Stack Trace window Event(*.EVN) Event Manager Console (*.LOG) Console window All (*.*) All files Save range (save range setting area) This area is displayed if the current window to be saved is the Assemble window, Memory window, Source window. Specify the range of data to be saved by selecting any of the following: 86 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE All Saves the entire range, from the first line to the last line. Screen shot Saves the area visible on the screen, from the top line on the screen to the bottom line. If the Source window is in the mixed display mode, however, the window contents are saved from the source line that includes the area visible on the screen. Specify Line Specify Address above any Specify the start line and end line of the area to be saved. If the start line and end line are omitted, the first line and last line are assumed. For details, it is as follows. Specify Line (if current window is Source window) Specify the range of the line numbers to be saved. The default radix for inputting a numeric value is decimal. If the Source window is in the mixed display mode, the mixed displayed part on the specified line is also saved. If a range of 100 lines or more is specified, a message dialog box is displayed to indicate the progress of saving. To stop saving midway, click the <Stop> button in the message dialog box. Specify Address (if current window is Assemble window, or Memory window) This area is used to specify the address range in which data is to be saved to the file. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. If a range of 256 bytes or more is specified, a message dialog box is displayed to indicate the progress of saving. To stop saving midway, click the <Stop> button in the message dialog box. Function buttons Save Saves the information of the current dialog box to the selected file. After saving, the dialog box is closed. Cancel Closes this dialog box without saving the file. Help Opens the Help window. Restore Restores the status before this dialog box was opened. User’s Manual U16525EJ1V0UM 87 CHAPTER 7 WINDOW REFERENCE View File Load dialog box This dialog box is used to read the view file, source file, text file, event setting file, watch setting file, or peripheral I/O register setting file saved in the View File Save dialog box, and open a window. The window to be opened and its status differ as follows, depending on the file to be loaded. Loading source file to which symbol information has been read If there is a Source window in the active status, it is opened in the static status; otherwise, the Source window is opened in the active status. Loading source file to which symbol information has not been read, or view file A window of text-format files is opened in the Source window in the static status. Loading event setting file The Event Manager is opened, and the event setting contents will return to the previous environment. Loading watch setting file The Watch window is opened, and the watch setting contents will return to the previous environment. Loading peripheral I/O register setting file The IOR window is opened, and the peripheral I/O register setting contents will return to the previous environment. Figure 7-13 View File Load Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons 88 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Opening This dialog box can be opened as follows: • Click the Open button. • Select [File] -> [Open...] on the menu bar (or press Alt+F and O in that order, or press Ctrl+O). Explanation of each area This dialog box consists of the following areas: (2) Files of type: (extension selection area) (1) Look In:, File name: (file selection area) (1) Look In:, File name: (file selection area) This area is used to specify a file name. A file name can be directly input from the keyboard, or selected from the list at the upper part of this area. Up to 64 character string with a extension can be specified. (2) Files of type: (extension selection area) This area is used to specify the type (extension) of the file to be loaded. Table 7-6 Type of File That Can Be Loaded on View File Load Dialog Box File Type (Extension) Meaning Source (*.C, *.S) Source file The extension of the source (c, s) can be changed in Debugger Option dialog box. Text (*.TXT) Text file Source Text (*.SVW) Source windowView files Assemble (*.DIS) Assemble window view files Memory (*.MEM) Memory window view files Watch (*.WCH) Watch window setting files Caution : Can not load the variable value. Register (*.RGW) Register window view files I/O Register (*.IOR) IOR window setting files Caution : Can not load the variable value. Local Variable (*.LOC) Local Variable window view files Stack Trace (*.STK) Stack Trace window view files Event (*.EVN) Event setting file Console (*.LOG) Console window All (*.*) All files User’s Manual U16525EJ1V0UM 89 CHAPTER 7 WINDOW REFERENCE Function buttons 90 Open Loads the selected file. After loading the file, this dialog box is closed. Cancel Closes this dialog box without loading the file. Help Opens the Help window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Download dialog box This dialog box is used to select the name and format of a file to be downloaded, and downloads memory contents to the in-circuit emulator and the target system. If a load module file has been downloaded, the corresponding source file is searched, and Source window is automatically opened. Up to 20 load module files can be downloaded. To check the loaded files, use Load Module List dialog box that is opened when [File] -> [Load Module] is selected from the menu bar. In this dialog box, a file can be downloaded to the internal flash memory (refer to "Flash Memory Writing Function"). Format of file that can be downloaded • Load module (ELF (.OUT)) • Intel Hex format (standard, extended) • Motorola Hex format S type (S0, S2, S3, S7, S8) • Extended Tektronix Hex format • Binary data Caution If a file other than a load module file is loaded, source debugging cannot be executed. Figure 7-14 Download Dialog Box User’s Manual U16525EJ1V0UM 91 CHAPTER 7 WINDOW REFERENCE This section explains the following items: • Opening • Explanation of each area • Function buttons • Cancel processing Opening This dialog box can be opened as follows: • Click the Load button. • Select [File] -> [Download...] on the menu bar (or press Alt+F, and D in that order). Explanation of each area (2) Files of type: (extension selection area) (3) Load (load condition specification area) (4) Reset (reset condition specification area) (5) Offset Address: (offset setting area) (1) Look In:, File name: (file selection area) (1) Look In:, File name: (file selection area) This area is used to specify a file name. A file name can be directly input from the keyboard, or selected from the list at the upper part of this area. Two or more files can be specified in this dialog box. To specify two or more files, delimit each file name with " " (double quotation mark). Files can also be specified by clicking the mouse button while holding down the Shift or Ctrl key. Up to 64 character string with a extension can be specified. (2) Files of type: (extension selection area) This area is used to specify the type (extension) of the file to be downloaded. The contents displayed on the drop-down list are as follows: Table 7-7 Type of File That Can Be Downloaded Contents (extension) 92 Format Load Module(*.OUT) Load module Hex Format(*.HEX) Hex format (automatic format identification) Binary Data(*.BIN) Binary data User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Reference These are default extensions; other extensions can also be used. The default extension of the displayed load module can also be specified under Default Extension (default extension specification area) in Debugger Option dialog box. (3) Load (load condition specification area) This area is used to set a load condition. This setting is valid only if a file in the load module format is specified. (4) Symbol Specifies whether symbol information is read (when checked, default) or not. The memory capacity can be saved by not reading symbol information when a program consisting of two or more load module files is to be debugged and if the symbol information of some modules does not have to be read. Object Specifies whether object information is read (when checked, default) or not. Erase Specifies whether the contents of the internal flash memory are erased all before download (when checked, default) or not (only a product with internal flash memory). Reset (reset condition specification area) This area is used to set a reset condition. This setting is valid only if a file in the load module format is specified. (5) Symbol Specifies whether symbol information is reset (when checked, default) or not. When debugging a program consisting of two or more load module files, load each one of the load module files without resetting the symbol information. When downloading two or more load module files, take care that location addresses do not overlap. CPU Specifies whether the CPU is reset or not (not checked, default). Offset Address: (offset setting area) This area is used to specify the offset address that is used when a file is loaded (for binary data, specify the start address). An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. User’s Manual U16525EJ1V0UM 93 CHAPTER 7 WINDOW REFERENCE Function buttons Open Loads the selected file. After loading the file, this dialog box is closed. Cancel Closes this dialog box without loading the file. Help Opens the Help window. Restore Restores the input data to the original status. Cancel processing The following dialog box appears while downloading and the downloading can be cancelled at any time. The progress of the download is displayed in the dialog box. This dialog box is closed automatically after completing downloading. If an error occurs during the download, an error message will be displayed in a new window. Figure 7-15 94 The Progress of Download User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Upload dialog box This dialog box is used to set the name and format of the file to which memory contents are to be saved. Format of specifiable file • Intel Hex format (extended ... 20-bit address) • Motorola Hex format (S0, S3, S7 ... 32-bit address) • Extended Tektronix Hex format • Binary data format Figure 7-16 Upload Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [File] -> [Upload...] on the menu bar (or press Alt+F, and U in that order). User’s Manual U16525EJ1V0UM 95 CHAPTER 7 WINDOW REFERENCE Explanation of each area The Upload dialog box consists of the following areas: (2) Save as type: (extension selection area) (3) Save Address: (save range setting area) (1) Save in:, File name: (saved file name specification area) (1) Save in:, File name: (saved file name specification area) This area is used to specify a file name. A file name can be directly input from the keyboard, or selected from the list at the upper part of this area. Up to 64 characters can be specified including the extension. (2) Save as type: (extension selection area) This area is used to specify the type (extension) of the file. The format of the data to be saved to the file is determined by the extension. If "All (*.*)" is selected, however, the default Intel extended Hex format is selected. The contents displayed on the drop-down list are as follows: Table 7-8 Type of File That Can Be Uploaded Contents (extension) Format Intel Hex (*.HEX) Intel extended Hex format Motorola Hex (*.HEX) Motorola Hex format Tektro Hex (*.HEX) Extended Tektronix Hex format Binary Data (*.BIN) Binary data format All (*.*) All files Reference These are default extensions; other extensions can also be used. (3) Save Address: (save range setting area) This area is used to specify the address range in which data is to be saved to the file. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. Function buttons 96 Save Saves data in the specified setting. Cancel Closes this dialog box without saving the data to the file. Help Opens the Help window. Restore Restores the input data to the original status. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Load Module List dialog box This dialog box can be used to check the file name and file path name of a load module that has already been downloaded. By using the <Download> button, The Download dialog box can be opened and a load module can be downloaded. Figure 7-17 Load Module List Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [File] -> [Load Module...] on the menu bar (or press Alt+F, and L in that order). Explanation of each area The Load module list dialog box consists of the following items: (2) Add Path (path name addition check box) (1) Module list (file name display area) User’s Manual U16525EJ1V0UM 97 CHAPTER 7 WINDOW REFERENCE (1) Module list (file name display area) This area displays the names of the load module files that have already been downloaded. The numbers displayed in the "No." field indicate the sequence in which the load module file names were read. The file names are displayed with the full path if the path name addition check box is checked; otherwise, only the file names will be displayed. If the file names do not fit in the screen, the screen can be scrolled by using the mouse or the arrow keys of the keyboard. If symbol information has been reset in the Reset Debugger dialog box box, or if symbol information has been reset in the Download dialog box, the load module file names downloaded before that are cleared. (2) Add Path (path name addition check box) This area is used to specify whether load module file names are displayed with the path (checked) or only file names are displayed (not checked, default) in the file name display area. Function buttons 98 Close Closes this dialog box. Help Opens the Help window. Download... Opens Download dialog box. A new load module can be downloaded. The file name of the newly downloaded module will be added to the file name display area when the Download dialog box is closed. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Browse dialog box This dialog box is used to select the file to be set in the Source Search dialog box or the Source Text move dialog box. Reference If this dialog box is opened for the first time after the system has been started up, the directory first specified by the source path is displayed. When the dialog box is opened the second and subsequent times, the previously displayed directory is recorded and displayed again. If the <Cancel> button is pressed, however, the previously displayed directory is not recorded. Figure 7-18 Browse Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Click the <Browse...> button in the Source Search dialog box or the Source Text move dialog box. User’s Manual U16525EJ1V0UM 99 CHAPTER 7 WINDOW REFERENCE Explanation of each area The Browse dialog box consists of the following areas: (2) Files of type: (extension selection area) (1) Look In:, File name: (file selection area) (1) Look In:, File name: (file selection area) This area is used to specify a file name. A file name can be directly input from the keyboard, or selected from the list at the upper part of this area. Up to 64 character string with a extension can be specified. (2) Files of type: (extension selection area) This area is used to specify the type (extension) of the file to be opened. Table 7-9 Type of File That Can Be Displayed in Browse Dialog Box File Type (Extension) Meaning Source (*.C, *.S) Source file The extension of the source (c, s) can be changed in Debugger Option dialog box. Text(*.TXT) Text file All(*.*) All files Function buttons 100 Open Sets the selected file. After setting the file, closes this dialog box. Cancel Does not set the file and closes this dialog box. Help Opens the Help window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Source Text move dialog box This dialog box is used to specify a file to be displayed in the Source window and the position from which displaying the file is to be started. This dialog box is selected if [View] -> [Move...] is selected from the menu bar while the Source window is open, and enables the display start position of a file to be changed (a new window is not opened). Figure 7-19 Source Text Move Dialog Box This section explains the following items: • Opening • Explanation of each area • Specifying • Specifying a display start position by an address (or symbol). • Specifying a file to be displayed in the Source window • Function buttons Opening This dialog box can be opened as follows: When the Source window is active • Select [View] -> [Move...] (or press Alt+V and V in that order, or press Ctrl+J). Explanation of each area The Source Move dialog box consists of the following areas: (2) To (file/address specification area) (1) Option (input mode selection area) User’s Manual U16525EJ1V0UM 101 CHAPTER 7 WINDOW REFERENCE (1) Option (input mode selection area) This area is used to select the input mode when the display start position is specified. (2) Address/Symbol If the display start position is specified by an address (or symbol) Line/File If the display start position is specified by a line number (or file name) To (file/address specification area) This area is used to specify the file name or address to be displayed. In the default condition, the character string selected in the window that called this dialog box is displayed in this area. If no character string has been selected, the first character string of the input history is displayed. If no input history is available, the current PC is displayed. As necessary, the character string displayed in this area can be changed by directly inputting a character string from the keyboard. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. Specifying On this dialog box, the following two items can be specified. • Specifying a display start position by an address (or symbol). • Specifying a file to be displayed in the Source window Specifying a display start position by an address (or symbol). Select Address/Symbol under Option and specify the address from which display is to be started for To. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. Clicking the <OK> button displays the source text so that the source line corresponding to the specified address value can be viewed. Specifying a file to be displayed in the Source window Select Line/File under Option and specify the name of the file to be displayed in the Source window for To. Specification can be mode using only the file name, or using an absolute path or relative path. If only the file name is specified, or if a relative path is specified, the files in the directory of the source path specified in Debugger Option dialog box are sequentially searched. The file that is found first as a result of searching is displayed. In addition to a file name, a line number can be also specified as follows: <<path name>file name#>line number 102 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Delimit the file name from the line number with "#". Specify the line number in decimal. The file name may be omitted. The default radix for inputting a numeric value is hexadecimal. Clicking the <OK> button displays the specified file with the specified line number as the first line. If the file name omitted, the file being displayed is displayed starting from the specified line. If the line number is omitted, the file is displayed starting from its first line. Function buttons Browse... Opens the Browse dialog box. OK Starts displaying the source text from the specified position. Cancel Closes this dialog box. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 103 CHAPTER 7 WINDOW REFERENCE Address move dialog box This dialog box is used to specify the address from which displaying memory contents, results of disassembly, or I/O registers are to be displayed. This dialog box is displayed if [View] -> [Move...] is selected from the menu bar while the Memory window, the Assemble window, or the IOR window is opened, and enables the display start address of data to be changed. Figure 7-20 Address Move Dialog Box (Example: When Memory Window Is Open) This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: When the Memory window, Assemble window, or IOR window is opened • Select [View] -> [Move...] from the menu bar (or press Alt+V and V in that order, or press Ctrl+J). Explanation of each area The Address Move dialog box consists of the following areas: (1) To (address specification area) 104 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) To (address specification area) This area is used to specify an address. In the default condition, the string selected in the window that called this dialog box, the current PC value (Memory window, Assemble window), or blank (IOR window) is displayed. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. Function buttons OK Displays the memory contents, results of disassembly, or I/O registers. Cancel Closes this dialog box. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 105 CHAPTER 7 WINDOW REFERENCE Symbol To Address dialog box Displays the address of the specified variable or function, or the value of the specified symbol. Figure 7-21 Symbol To Address Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [View] -> [Symbol...] from the menu bar (or press Alt+V and Y in that order). Explanation of each area The Symbol To Address dialog box consists of the following areas: (2) Radix (display radix specification area) (1) Symbol: (symbol specification and conversion result display areas) (1) Symbol: (symbol specification and conversion result display areas) The upper area (symbol specification area) is used to specify the variable, function name, symbol name, or line number to be converted. In addition, an I/O port name, peripheral I/O register name, register name, PSW flag name, or expression can be also specified. 106 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE In the lower area (conversion result display area), the variable, address of the function, value of the symbol, address of the line number, or value of the expression specified under Symbol is displayed. The address value of an I/O port name or peripheral I/O register name, the register contents of a register name, or flag value of a PSW flag name is displayed. The specification method is indicated below. Table 7-10 Specifying Symbols Conversion Target Specification Method Variable var file#var (to specify a static function with file name) func#var (to specify a static function with function name) file#var (to specify a static function with file name and function name) Function func file#func (to specify a static function with file name) Label label file#label(to specify a local label with file name) Line number of source file prog$file#var file#no I/O Port portname I/O Register I/O regname Register regname PSW Flag pswname Remark var: Variable name, func: Function name, file: File name, label: Label name, bitsym: Bit symbol name, portname: I/O port name, I/O regname: Peripheral I/O register name, regname: Register, pswname: PSW flag name, no: Line number of source file "#" is used as a separator for file names, variables, function names, and line numbers. If a specified symbol is not found in the scope, all symbols (static variables, static functions, local labels) are searched. In the default status, a symbol name takes precedence. To temporarily change the priority, prefixing "$" to a symbol gives the priority to a register name. To specify a load module name when two or more load modules are read, use "$" as a separator to delimit the load module name from a file name, variable, function name, or symbol name. In the default condition, the character string selected in the window that called this dialog box is displayed. As necessary, input data from the keyboard to change the character string. The default radix for inputting a numeric value is decimal. To change the contents of the symbol specification area, click the <OK> button. The conversion result will be displayed in the conversion result display area. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. User’s Manual U16525EJ1V0UM 107 CHAPTER 7 WINDOW REFERENCE (2) Radix (display radix specification area) This area is used to specify the radix of the data to be displayed in the conversion result display area. Hex Hexadecimal number (default). Dec Decimal number Oct Octal number Bin Binary number Function buttons 108 OK If the contents of the symbol specification area have been changed, converts the symbol. After conversion, closes the dialog box if the contents of the symbol specification area have not been changed. Cancel Closes this dialog box. Restore Restores the input data to the original status. If the <OK> button has already been clicked, the data is restored to the status immediately after the <OK> button was clicked. Help Opens the Help window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Source window This window displays source files or text files. In Mixed display mode, the program can be disassembled and displayed and online assembly can be executed while source files are being displayed. The Source window that is displaying the source file to which symbol information is read may be in two statuses: Active Status and Static Status. Caution If program codes is described in an include file and these codes are included in multiple files, the line numbers and addresses do not correspond on a one-to-one bases. In such an include file, function that indicates the correspondence relationship between line numbers and addresses dose not correctly operate. Figure 7-22 Source Window This section explains the following items: • Opening • Explanation of each area • Breakpoint setting/deletion function • Functions often used (right-click menu) • Function buttons • Related operations User’s Manual U16525EJ1V0UM 109 CHAPTER 7 WINDOW REFERENCE Concerning display • Mixed display mode • To set a source path • To change the display start position • To display another source file • To specify the default extension of a source file • To convert a symbol • To specify the symbol of a start-up routine • To set an opened file history • To set a beep sound to be issued upon break • To change the displayed font • To change the displayed tab size Concerning operation • [Start From Here] function • [Come Here] function • Program counter setting function • Jump Function • To change disassembled contents • Watch function (referencing data value) • To search in a source program • To set a default breakpoint • Drag & drop function (line/address) • Drag & drop function (character string) Opening This window can be opened as follows: • This window is automatically opened if the corresponding source file exists after the download module file has been downloaded. • Click the Src button. • Select [Browse] -> [Source] from the menu bar (or press Alt+B, and S in that order). • Select [Jump] -> [Source] from the menu bar (or press Alt+J and S in that order, or press Ctrl+U). • Click the <Open> button with selecting a source file or text file in the View File Load dialog box. 110 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Explanation of each area The Source window consists of the following areas: (2) Current PC mark area (3) Line number/address display area (4) Source text display area (1) Point mark area (1) Point mark area This area displays the Breakpoint setting/deletion function, Event setting status, and Program code. The 'B' mark is displayed in the following colors, depending on the type and status of the breakpoint. A breakpoint becomes valid as soon as it has been set in the point mark area. Table 7-11 Display Color of Breakpoint and Its Meaning Display Color Meaning B (blue) Software breakpoint is set. B (red) Valid hardware breakpoint (after execution) is set. B (green) Valid hardware breakpoint (before execution) is set. Remark: Breaks before execution (B) are set with priority. B (black) Invalid hardware breakpoint is set. This hardware breakpoint can be validated on the Event Manager or in the Break dialog box. Breakpoint setting/deletion function By clicking this area with the mouse, a breakpoint can be set or deleted. Whether a hardware breakpoint or software breakpoint is to be set or deleted can be selected by the right-click menu of this area (or by On Mouse Click in the Extended Option dialog box). Setting a breakpoint A breakpoint can be set on a line for which "*" is displayed in the point mark area (if "*" is not displayed for the line, the breakpoint is set on the line above or below the line, whichever has "*" displayed). If a breakpoint is set on a line on which an event breakpoint has already been set, "A" indicating that multiple events have been set is displayed. Deleting a breakpoint Click the position at which the breakpoint to be deleted is set. If right-click menu -> [Software Breakpoint] is selected, 'B (blue: software breakpoint' is deleted. If [Hardware Breakpoint] is selected, 'B (red: hardware break)' is deleted. If another event remains, User’s Manual U16525EJ1V0UM 111 CHAPTER 7 WINDOW REFERENCE however, the mark of that event is displayed. Table 7-12 Details of Setting/Deleting Breakpoint Display Status of Line On Mouse Click [right-click menu] Blank or with mark other than B Soft Break [Software Breakpoint] Sets a software breakpoint. Hard Break [Breakpoint] Sets a hardware breakpoint With B(blue) mark (Software breakpoint setting status) Soft Break [Software Breakpoint] Deletes a software breakpoint Hard Break [Breakpoint] Sets a hardware breakpoint With B(red, green, black) mark (Hardware breakpoint setting status) Soft Break [Software Breakpoint] Sets a software breakpoint. Hard Break [Breakpoint] Deletes a hardware breakpoint Operation on clicking Event setting status The setting status of various events can be displayed. If an execution event or access event is set on the corresponding line, a mark corresponding to the type of event is displayed. If an address range is specified as the address condition of the event, the lower addresses of the range are displayed. The mask specification of the address condition is not reflected. Table 7-13 Meaning of Event Display Mark Mark Meaning E Setting of event condition L Setting of event for event link condition B Setting of break event A Setting of multiple events Program code The line marked '*' in the point mark area indicates that a program code corresponding to the line number exists. This program code is displayed only if a load module has been downloaded and symbol information has been read. 112 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (2) Current PC mark area The mark '>', which indicates the current PC value (PC register value), is displayed in this area. Clicking this mark with the mouse displays a pop-up window that shows the PC register value. By double-clicking the current PC mark area, the program can be executed up to a specified line. (3) Line number/address display area This area displays the line numbers of a source file or text file. If a Program code corresponding to a line number of the source file exists, the character of the line number is displayed in red. If a program code does not exist, the character of the line number is displayed in black. In the mixed display mode, disassembled addresses are displayed. The characters of an address are displayed in gray. In this area, any position can be selected (highlighted) by clicking the mouse button. The selected line number of an address can be dragged to another window or area, so that its variable value can be displayed or the line number of the address can be specified as an event condition (refer to "Drag & drop function (line/address)"). (4) Source text display area This area displays source files or text files. In the mixed display mode, disassemble display and online assemble can also be executed (refer to "To change disassembled contents"). A data value can be temporarily displayed by selecting (highlighting) a character string and placing the mouse cursor over it (Balloon watch function). The current PC line and the line on which a breakpoint is set are emphasized for display, as follows: Current PC line (Yellow) This line is the source line or disassemble display line corresponding to the current PC value (indicated by '>'). Breakpoint setting line (red) This line is the source line or a disassemble display line on which a valid breakpoint is set (indicated by a 'B' mark in red, green or blue). In the mixed display mode, the color of only the disassemble display line is changed (the source line is displayed in the normal color). In this area, the following functions can be used on the line or address on which the cursor is placed (start address of program code): User’s Manual U16525EJ1V0UM 113 CHAPTER 7 WINDOW REFERENCE -> [Start From Here] function -> [Come Here] function -> Program counter setting function -> Jump Function Caution If a Program code does not exist on the source line, the top address of the line above or below the line on which a program code exists is manipulated by these functions. These functions cannot be performed in the following cases. The corresponding menu will be dimmed and cannot be selected. - If a file other than a source file is displayed - While the user program is being executed A character string selected in this area can be dragged and dropped to another window or dialog box (refer to "Drag & drop function (character string)"). Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. 114 Move... Moves the display position. Opens the Source Text move dialog box. Mix Turns on/off mixed display of disassembly. Checked: Mixed display Not checked: No display (default) Add Watch... Adds the specified data to the Watch window. Opens the Add Watch dialog box. Symbol... Displays the address of the specified variable or function, or the value of the specified symbol. Opens the Symbol To Address dialog box. Break when Access to this Variable Creates a break event for a read/write access. Break when Write to this Variable Creates a break event for a write access. Break when Read from this Variable Creates a break event for a read access. Clear Deletes the selected break event condition. Event? Displays the event information of the line at the cursor position or the selected variable. If an event is set, Event dialog box is opened. Come Here Executes the program from the current PC to the cursor position. Change PC Sets the address at the cursor position to the PC. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Break Point Sets or deletes a breakpoint at the cursor position. Remark: Breaks before execution (B) are set with priority. Software Break Point Sets or deletes a software break point at the cursor position. Assemble Disassembles and displays starting from the jump destination address specified by the data value at the cursor position. Opens the Assemble window. If an active Assemble window is open, that window is displayed in the forefront (so that it can be manipulated). Memory Displays the memory contents starting from the jump destination address specified by the data value at the cursor position. Opens the Memory window. If an active Memory window is open, that window is displayed in the forefront (so that it can be manipulated). Function buttons Search... Opens the Source Search dialog box and searches a character string of the source text. If a character string is selected in the source text display area, the Source Search dialog box is opened to search the character string. If no character string is selected, the Source Search dialog box is opened with nothing specified to be searched. Specify a search method in the Source Search dialog box. The result of search is highlighted in the Source window. This is the same operation as selecting [View] -> [Search...] from the menu bar. << Searches forward (upward on screen) for the text that satisfies the search condition set in the Source Search dialog box, starting from the address at the cursor position. This button is displayed as the <Stop> button during a search. >> Searches backward (downward on screen) for the text that satisfies the search condition set in the Source Search dialog box, starting from the address at the cursor position. This button is displayed as the <Stop> button during a search. Stop (during search) Stops searching. Watch Adds the variables selected in the source text display area to the Watch window. If the Watch window is not opened, it is opened. If no text is selected in the source text display area, the Watch window is only opened. This is the same operation as selecting [View] -> [View Watch] from the menu bar. Quick... Temporarily displays the contents, such as a variable, selected in the source text display area in the Quick Watch dialog box. Opens the Quick Watch dialog box. If no text is selected in the source text display area, the Quick Watch dialog box is only opened. This is the same operation as selecting [View] -> [Quick Watch] from the menu bar. Refresh Updates the contents of the window with the latest data. Close Closes this window. User’s Manual U16525EJ1V0UM 115 CHAPTER 7 WINDOW REFERENCE Related operations Mixed display mode The normal display mode and mixed display mode can be alternately selected by selecting [View] -> [Mix] from the menu bar. Normal display mode In the normal display mode, general text files can be displayed as well as source files. Mixed display mode In the mixed display mode, disassembly of programs combined with source files is displayed and online assembly is carried out. (This mode is valid only when a load module is being downloaded and symbol information is being read, and the source file that corresponds to the downloaded load module is displayed). If a program code corresponds to the line of the displayed source file, the disassembly line is displayed next to the source line. In the disassembly line, an address label, a code data, and a disassembled mnemonic are displayed (the starting position for display of the mnemonic can be adjusted by the tab size setting value). To execute online assembly, move the cursor to a mnemonic. The results of online assembly are also reflected in the Memory window. The contents displayed in the mixed display mode can be saved as a view file. To set a source path Set a source path under Source Path (source path specification area) in the Debugger Option dialog box that is opened by selecting [Option] -> [Debugger Option] from the menu bar. To change the display start position Change the display start position in the Source Text move dialog box that is opened when right-click menu -> [Move...] is selected in the Source window. To display another source file Select [File] -> [Open] from the menu bar and specify a file. To specify the default extension of a source file Set a source path under Default Extension (default extension specification area) in the Debugger Option dialog box that is opened by selecting [Option] -> [Debugger Option] from the menu bar. 116 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE To convert a symbol Convert symbols in the Symbol To Address dialog box that is opened when right-click menu -> [Symbol...] is selected in the Source window. To specify the symbol of a start-up routine Specify the symbol of a start-up routine under Startup Routine (start-up symbol setting area) in the Debugger Option dialog box that is opened by selecting [Option] -> [Debugger Option...] from the menu bar. If the setting in this area is wrong, the source file cannot be opened. To set an opened file history Set an opened file history under Open File History (open file history setting area) in the Debugger Option dialog box that is opened by selecting [Option] -> [Debugger Option...] from the menu bar. The number of a history display of the opened files can be specified in this area. To set a beep sound to be issued upon break Set the beep sound under Break Sound (beep sound specification area) in the Extended Option dialog box that is opened by selecting [Option] -> [Extended Option...] from the menu bar. To change the displayed font Change the displayed font in the Font dialog box that can be opened by clicking the <Font...> button in the Debugger Option dialog box that is opened when [Option] -> [Debugger Option...] is selected from the menu bar. To change the displayed tab size The displayed tab size can be specified for each file extension under Tab Size (tab size setting area) in the Debugger Option dialog box that is opened when [Option] -> [Debugger Option...] is selected from the menu bar. [Start From Here] function This function is used to execute the user program from the line on which the cursor is placed. Method Move the cursor to the line from which the program is to be executed, and select right-click menu -> [Start From Here]. [Come Here] function This function is used to execute the user program to the line on which the cursor is placed (while the user program is being executed in this mode, the break event currently set does not occur). Method Move the cursor to the line on which the break is to occur, and select right-click menu -> [Come Here]. Program counter setting function This function is used to set the address of the line on which the cursor is placed to the program counter (PC). Method Move the cursor to the line that is to be set to the PC, and select [Run] -> [Change PC] from the menu User’s Manual U16525EJ1V0UM 117 CHAPTER 7 WINDOW REFERENCE bar. To change disassembled contents To change the disassembled contents, move the cursor to the mnemonic field (the overwrite and insertion modes are alternately selected by pressing the Insert key). If an attempt is made to move the cursor to another line after the disassembled contents have been changed in the mnemonic field, the new contents are checked. If the new contents are illegal. the code data on the line where the contents have been changed is indicated as '*'. In this case, the new contents are not written to memory even if the cursor is moved to another line. The contents changed in the mnemonic field are written into the memory by pressing the Enter key. When the Enter key is pressed, the new contents are checked and, if they are illegal, the code data on the illegal line is indicated by '*'. If even one line is illegal, the new contents are not written into the memory. In this case, correct the contents. To discard the contents, press the ESC key. If the contents are correct and if the Enter key is pressed, the contents are written into the memory, and then the cursor moves to the next line in the mnemonic field, so that the data on the next line can be changed. Watch function (referencing data value) Data values can be displayed as follows: To temporarily display a value The following two methods can be used: • Select (highlight) a character string and put the mouse cursor on it then the data value is displayed (Balloon watch function). • Select (highlight) a character string and click the <Quick...> button. The Quick Watch dialog box will be opened to display the data value. To trace the change of a data value Register a variable or symbol to the Watch window in either of the following ways: • Select (highlight) the character string whose data value is to be displayed, click the <Watch> button, or drag the character string to the Watch window and register it to the window (Drag & drop function (character string)). • Select (highlight) the character string whose a data value is to be displayed and register the data value from the Add Watch dialog box that is opened when right-click menu -> [Add Watch] is selected. To search in a source program Use the Source Search dialog box that is opened by clicking the <Search...> button in the Source window. If the character string to be searched exists in the window, select that character string and click the <Search...> button. The selected character string will be opened in the specified format. To set a default breakpoint Set a default breakpoint under On Mouse Click (default break selection area) in the Extended Option dialog box that is opened when [Option] -> [Extended Option...] is selected from the menu bar. In this 118 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE way, a default breakpoint that is assumed when the point mark area is clicked can be set. Drag & drop function (line/address) The line number or address selected and highlighted can be dragged to another window or area. If the position of the line number or address selected in this area is dragged with the left mouse button, the shape of the mouse cursor changes from an arrow to '-'. When the cursor is moved to the window or area in which they can be dropped, the mouse cursor changes to 'OK'. In the window in which the line number of the address has been dropped, an operation is performed on the dropped address or the address that is obtained from the dropped line number. The operation to be performed after dropping the line number or address differs, depending on the window or area in which the line number or address has been dropped. Table 7-14 Details of Drag & Drop Function (Line/Address) Window/Area to Drop to Operation After Drop The Event Manager or the event manager area in each various event setting dialog box Automatically creates an execution event condition by using the dropped line number or address as an address condition. Event condition names are automatically created as Evt00001, Evt00002, and so on. The address condition is set for the closest symbol in the format of symbol name + offset value. Condition setting area in each various event setting dialog box (other than address and data setting areas) Automatically creates an execution event condition by using the dropped line number or address as an address condition. The automatically created event condition is set in each condition setting area in which the line number or address has been dropped. Event condition names are automatically created as Evt00001, Evt00002, and so on. The address condition is set for the closest symbol in the format of symbol name + offset value. Condition setting area in each various event setting dialog box (address and data setting areas) The text of the dropped line number or address is set in the area in which the line number or address has been dropped. The address condition is set for the closest symbol in the format of symbol name + offset value. Caution The various event setting dialog boxes includes the Event dialog box, Event Link dialog box, and Break dialog box. Drag & drop function (character string) A selected text can be moved to another window or area by dragging and dropping. 1 If the selected text is dragged by using the left mouse button, the shape of the mouse cursor changes from an arrow to '-'. 2 When the cursor is moved to the window or area in which the text can be dropped, the mouse cursor changes to 'OK'. The operation to be performed after dropping the text differs, depending on the window or area in which the text has been dropped. User’s Manual U16525EJ1V0UM 119 CHAPTER 7 WINDOW REFERENCE Table 7-15 Details of Drag & Drop Function (Character String) Window/Area to Drop to Operation After Drop The Event Manager or the event manager area in each various event setting dialog box If the dropped text can be converted as a symbol into an address value, an event condition in the Access status (all access statuses) or Execute status is automatically created, using the converted address value as an address condition. Event condition names are automatically created as Evt00001, Evt00002, and so on. The address condition is set by the dropped text. The relationship between the event condition to be created and the symbol is as follows: Symbol Variable Function Symbol in the data section Symbol in the code section Other Condition setting area in each various event setting dialog box (other than address and data setting areas) If the dropped text can be converted as a symbol into an address value, an event condition in the Access status (all access statuses) or Execute status is automatically created, using the converted address value as an address condition. The automatically created event condition is set in each condition setting area in which the line number or address has been dropped. Event condition names are automatically created as Evt00001, Evt00002, and so on. The address condition is set by the dropped text. The relationship between the event condition to be created and the symbol is as follows: Symbol Variable Function Symbol in the data section Symbol in the code section Other Status Access(R/W) Execute Access(R/W) Execute Access(R/W) Condition setting area in each various event setting dialog box (address and data setting areas) The dropped text is set in the area. Watch window If the dropped text is recognizable as a symbol, the contents of the symbol are displayed. Caution The various event setting dialog boxes includes the Event dialog box, Event Link dialog box, and Break dialog box. 120 Status Access(R/W) Execute Access(R/W) Execute Access(R/W) User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Source Search dialog box This dialog box is used to search for the character string in the Source window. By setting each item and then clicking the <Find Next> button, searching can be started. By clicking the <Set Find> button, the direction buttons ("<<" and ">>") in the Source windowcan be used for the search. Figure 7-23 Source Search Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: When Source window is displayed • Click the <Search> button. (or press Ctrl and G in that order). • Select [View] -> [Search...] (or press Alt+V, and S in that order). Explanation of each area The Source Search dialog box consists of the following areas: (2) Match Case (search condition specification area) (3) Direction (search direction specification area) (4) File (search file specification area) (1) Find What (search data specification area) User’s Manual U16525EJ1V0UM 121 CHAPTER 7 WINDOW REFERENCE (1) Find What (search data specification area) This area is used to specify the data to be searched. In the default condition, the character string selected in the window that called this dialog box is displayed. As necessary, input data from the keyboard to change the character string. Up to 256 character string can be specified. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. (2) Match Case (search condition specification area) This area is used to specify whether uppercase and lowercase characters are distinguished, before searching is started. (3) Checked Distinguished (default) Not checked Not distinguished Direction (search direction specification area) This area is used to specify the direction of the search. (4) Up Forward search. Searches data forward (upward on screen) from the current position of the cursor. Down Backward search (default). Searches data backward (downward on screen) from the current position of the cursor. File (search file specification area) This area is used to specify the file to be searched. If no file is specified, searching is executed in the window that called this dialog box. 122 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Function buttons Find Next Searches the specified data in accordance with a given condition. If the specified character string is found as a result of a search, it is highlighted. To continue searching, click this button again. Set Find Sets the specified condition as the search condition and closes this dialog box. Stop (during search) Stops searching. Cancel Closes this dialog box. This button is displayed as the <Stop> button while data is being searched. Browse... Opens Browse dialog box. Help Opens the Help window. User’s Manual U16525EJ1V0UM 123 CHAPTER 7 WINDOW REFERENCE Assemble window This window is used to disassemble and display programs. It is also used to execute online assembly. To execute online assembly, move the cursor to a mnemonic. The results of online assembly are also reflected in the Memory window. The Assemble window has two statuses: Active Status and Static Status. Figure 7-24 Assemble Window This section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons • Related operations Concerning display • To change the display start position • To change the displayed offset and register name Concerning operation • [Start From Here] function • [Come Here] function • Program counter setting function • Jump Function • To change disassembled contents 124 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE • Watch function (referencing data value) • To search in the Assemble window • Drag & drop function (line/address) • Drag & drop function (character string) Opening This window can be opened as follows: • Click the Asm button. • Select [Browse] -> [Assemble] from the menu bar (or press Alt+B, and A in that order). • Select [Jump] -> [Assemble] from the menu bar (or press Alt+J and A in that order, or press Ctrl+D). Explanation of each area The Assemble window consists of the following areas: (2) Current PC mark area (3) Address specification area (4) Disassemble display area (1) Point mark area (1) Point mark area This area is displayed the Breakpoint setting/deletion function and the Event setting status. (2) Current PC mark area The mark '>', which indicates the current PC value (PC register value), is displayed in this area. By double-clicking the current PC mark area, the program can be executed up to a specified line. User’s Manual U16525EJ1V0UM 125 CHAPTER 7 WINDOW REFERENCE (3) Address specification area This area displays the disassembly start address. When this area is clicked, an address highlighted and selected. This area has the Drag & drop function (line/address). (4) Disassemble display area This area displays the labels and code data of addresses, and disassembled mnemonics. The current PC line and breakpoint setting line are displayed in different colors for emphasis. The disassembled mnemonics displayed in the mnemonic field can be changed (refer to "To change disassembled contents"). If the number of new instruction bytes is less than the number of previous instruction bytes as a result of changing, as many 'NOP' instructions as necessary are inserted. If the number of new instruction bytes is more than the number of previous instruction bytes, the next instruction is overwritten. In this case also, as many 'NOP' instructions as necessary are inserted. The same applies to instructions that straddle over source lines. In this area, the following functions can be used on the line or address on which the cursor is placed (start address of program code): -> [Start From Here] function -> [Come Here] function -> Program counter setting function -> Jump Function A character string selected in this area can be dragged and dropped in another window or dialog box (refer to "Drag & drop function (character string)"). Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. 126 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Move... Moves the display position. Opens the Address move dialog box. Add Watch... Adds the specified data to the Watch window. Opens the Add Watch dialog box. Symbol... Displays the address of the specified variable or function, or the value of the specified symbol. Opens the Symbol To Address dialog box. Come Here Executes the program from the current PC to the cursor position. Change PC Sets the address at the cursor position to the PC. Break Point Sets or deletes a breakpoint at the cursor position. Remark: Breaks before execution (B) are set with priority. Software Break Point Sets or cancels a software break point at the cursor position. Source Text Displays the corresponding source text and source line, using the data value at the cursor position as the jump destination address. If no line information exists at the jump destination address, however, you cannot jump. Opens the Source window. If an active Source window is open, that window is displayed in the forefront (so that it can be manipulated). Memory Displays the memory contents starting from the jump destination address specified by the data value at the cursor position. Opens the Memory window. If an active Memory window is open, that window is displayed in the forefront (so that it can be manipulated). Function buttons Search... Opens the Assemble Search dialog box and searches for a character string of mnemonics. If a character string is selected in the disassemble display area, the Assemble Search dialog box is opened to search for the character string. If no character string is selected, the Assemble Search dialog box is opened with nothing specified to be searched. Specify a search method in the Assemble Search dialog box. The result of search is highlighted in the Assemble window. This is the same operation as selecting [View] -> [Search...] from the menu bar. << Searches forward (upward on screen) for the contents that satisfy the search condition set in the Assemble Search dialog box, starting from the address at the cursor position. This button is displayed as the <Stop> button during a search. >> Searches backward (downward on screen) for the contents that satisfy the search condition set in the Assemble Search dialog box, starting from the address at the cursor position. This button is displayed as the <Stop> button during a search. Stop (during search) Stops searching. User’s Manual U16525EJ1V0UM 127 CHAPTER 7 WINDOW REFERENCE Watch Adds the symbols selected in the disassemble display area to the Watch window. If the Watch window is not opened, it is opened. If no text is selected in the disassemble display area, the Watch window is only opened. This is the same operation as selecting [View] -> [View Watch] from the menu bar. Quick... Temporarily displays the contents, such as symbols, selected in the disassemble display area on the Quick Watch dialog box. Opens the Quick Watch dialog box. If no text is selected in the disassemble display area, the Quick Watch dialog box is only opened. This is the same operation as selecting [View] -> [Quick Watch...] from the menu bar. Refresh Updates the contents of the window with the latest data. Close Closes this window. Related operations To change the display start position Change the display start position in the Address move dialog box, which is opened when right-click menu -> [Move...] is selected in the Assemble window. To change the displayed offset and register name Change the display offset or register name under DisAssemble (offset display setting area) in the Debugger Option dialog box that is opened when [Option] -> [Debugger Option...] is selected from the menu bar. A function name or an absolute name can be selected as a register name. To search in the Assemble window Use the Assemble Search dialog box, which can be opened by clicking the <Search...> button in the Assemble window. If the character string to be searched is existed in the window, select that character string and click the <Search...> button. The selected character string is opened in the specified format. 128 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Assemble Search dialog box This dialog box is used to search the contents of Assemble window. Successive character strings included in an input character string and disassembler character string are compared as one blank character. By setting each item and then clicking the <Find Next> button, searching can be started. By clicking the <Set Find> button, the direction buttons ("<<" and ">>") in the Assemble windowcan be used for the search. Figure 7-25 Assemble Search Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: When Assemble windowis the current window • Click the <Search> button. (or press Ctrl+G). • Select [View] -> [Search...] (or press Alt+V, and S in that order). Explanation of each area The Assemble Search dialog box consists of the following areas: (2) Match Case (search condition specification area) (3) Scan Whole Region (search condition specification area) (4) Direction (search direction specification area) (1) Find What (search data specification area) User’s Manual U16525EJ1V0UM 129 CHAPTER 7 WINDOW REFERENCE (5) Address (search range specification area) (1) Find What (search data specification area) This area is used to specify the data to be searched. In the default condition, the character string selected in the window that called this dialog box is displayed. As necessary, input data from the keyboard to change the character string. Up to 256 character string can be specified. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. (2) Match Case (search condition specification area) This area is used to specify whether uppercase and lowercase characters are distinguished, before searching is started. (3) Checked Distinguished (default) Not checked Not distinguished Scan Whole Region (search condition specification area) This area is used to specify whether the specified range is fully searched or not. (4) Checked Searches the entire range. Not checked Searches the remaining part of the range (default) Direction (search direction specification area) This area is used to specify the direction of the search. 130 Up Forward search. Searches data forward (upward on screen) from the current position of the cursor. Down Backward search (default). Searches data backward (downward on screen) from the current position of the cursor. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (5) Address (search range specification area) This area is used to specify the address to be searched. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. Function buttons Find Next Searches the specified data in accordance with a given condition. If the specified character string is found as a result of a search, it is highlighted. To continue searching, click this button again. Set Find Sets the specified condition as the search condition and closes this dialog box. Stop (during search) Stops searching. Cancel Closes this dialog box. This button is displayed as the <Stop> button while data is being searched. Help Opens the Help window. User’s Manual U16525EJ1V0UM 131 CHAPTER 7 WINDOW REFERENCE Memory window This window is used to display and change the memory contents. The display start position when the Memory window is opened is as follows: First time Display starts from the first address of the RAM sampling area, if the RAM sampling function is enabled. If it is disable, display starts from the first address of internal RAM area. Second and subsequent times Display starts from the address at which an active status window was closed (if an active status window has never been closed, display starts from the first display start position) ( Even while the program is being executed, any 1 KB in the internal RAM area the display range set ) in the Extended Option dialog box can be displayed. The Memory window has two statuses: Active Status and Static Status. Figure 7-26 Memory Window This section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons • Related operations • To change the memory contents • To change the display start position • To search in the Memory window • To display ASCII characters • To initialize the memory contents with a specified code 132 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE • To copy the memory contents • To compare the memory contents • To verify and check a memory write • To change the memory contents during program execution (DMM function) Opening This window can be opened as follows: • Click the Mem button. • Select [Browse] -> [Memory...] from the menu bar (or press Alt+B, and M in that order). • Select [Jump] -> [Memory...] from the menu bar (or press Alt+J, and M in that order). Explanation of each area The Memory window consists of the following areas: (2) +0 +1 +2....(memory display area) (3) 0 1 2 3.... (ASCII display area) (1) Addr (address display area) (1) Addr (address display area) This area displays memory addresses. (2) +0 +1 +2....(memory display area) This area is used to display and change the memory contents. Data into which the current memory contents are to be changed is displayed in red and is actually written to the target memory when the Enter key is pressed. The contents (displayed in red) can be canceled by the ESC key. Up to 256 bytes can be specified at one time. This area is also used as a jump pointer of the jump function. User’s Manual U16525EJ1V0UM 133 CHAPTER 7 WINDOW REFERENCE (3) 0 1 2 3.... (ASCII display area) This area is used to display and change the memory contents in ASCII characters. This area is displayed when right-click menu -> [Ascii] is selected. Display of this area can be turned on/off by this menu item. Data can be changed in this area in the same manner as in the memory display area. This area is also used as a jump pointer of the jump function. Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. Move... Moves the display position. Opens the Address move dialog box. Bin Displays binary numbers. Oct Displays octal numbers. Dec Displays decimal numbers. Hex Displays hexadecimal numbers (default). Nibble Displays in 4-bit units. Byte Displays in 8-bit units (default). Half word Displays in 16-bit units. Word Displays in 32-bit units. Ascii Turns on/off display of ASCII characters. Checked: Displayed Not checked: No display (default) Function buttons Search... 134 Opens the Memory Search dialog box and searches for character strings from the displayed memory contents, or memory contents. Selected data (a memory value) is displayed in the Memory Search dialog box as data to be searched. If the Memory Search dialog box is opened without data specified, specify data from the keyboard. The result of the search is highlighted in the Memory window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE << Searches the memory contents satisfying the search condition set in the Memory Search dialog box, forward (upward on screen) from the address at the cursor position. This button is displayed as the <Stop> button during a search. >> Searches the memory contents satisfying the search condition set in the Memory Search dialog box, backward (downward on screen) from the address at the cursor position. This button is displayed as the <Stop> button during a search. Stop (during search) Stops searching. Refresh Updates the contents of the window with the latest data. Modify... Opens the DMM dialog box. Close Closes this window. Related operations To change the memory contents To change the memory contents, move the cursor to the memory display area or ASCII display area in the window, and write data directly from the keyboard. The amount of memory contents that can be changed at one time is 256 bytes or less. To set the change, press the return key. To cancel the change, press the ESC key. To change the display start position Use the Address move dialog box, which can be opened by selecting right-click menu -> [Move...] in the Memory window. To search in the Memory window Use the Memory Search dialog box, which can be opened by clicking the <Search...> button in the Memory window. If the character string to be searched exists in the window, select that character string and click the <Search...> button. The selected character string is opened in the specified format. Non-mapped, peripheral I/O register, and I/O protect areas are not searched. To display ASCII characters The memory contents are displayed in ASCII characters when right-click menu -> [Ascii] is selected in the Memory window. To turn off display of ASCII characters, select [Ascii] again to remove the check mark. To initialize the memory contents with a specified code Initialize the memory contents with a specified code in the Memory Fill dialog box, which can be opened by selecting [Edit] -> [Memory] -> [Initialize] from the menu bar. If verify check is enabled in the Extended Option dialog box, verify check is executed after initialization. User’s Manual U16525EJ1V0UM 135 CHAPTER 7 WINDOW REFERENCE To copy the memory contents Copy the memory contents in the Memory Copy dialog box, which can be opened by selecting [Edit] -> [Memory] -> [Copy] from the menu bar. If verify check is enabled in the Extended Option dialog box, verify check is executed after copy. To compare the memory contents Compare the memory contents in the Memory Compare dialog box, which can be opened by selecting [Edit] -> [Memory] -> [Compare] from the menu bar. If a difference is found as a result of comparison, the Memory Compare Result dialog box is opened and the details are displayed in this dialog box. To verify and check a memory write Use the Extended Option dialog box, which is opened by selecting [Option] -> [Extended Option] from the menu bar. To execute a verify check, check the [Verify] check box. To change the memory contents during program execution (DMM function) Set addresses and data for DMM (Dynamic Memory Modification) in the DMM dialog box, which can be opened by selecting [Edit] -> [Memory] -> [Modify] from the menu bar. Nothing can be written to the internal ROM and internal flash memory. 136 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Memory Search dialog box This dialog box is used to search the memory contents of the part of Memory window at which the cursor is located. If the cursor is in the memory display area, the memory display area is searched for specified data, which is assumed to be a binary data string. If the cursor is in the ASCII display area, the ASCII display area is searched for specified data, which is assumed to be an ASCII character string. By setting each item and then clicking the <Find Next> button, searching can be started. By clicking the <Set Find> button, the direction buttons ("<<" and ">>") in the Memory window can be used for the search. Non-mapped, peripheral I/O register, and I/O protect areas are not searched. Figure 7-27 Memory Search Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: When Memory window is the current window • Click the <Search> button. (or press Ctrl+G). • Select [View] -> [Search...] (or press Alt+V, and S in that order). User’s Manual U16525EJ1V0UM 137 CHAPTER 7 WINDOW REFERENCE Explanation of each area The Memory Search dialog box consists of the following areas: (2) Unit (search condition specification area) (3) Scan Whole Region (search condition specification area) (4) Direction (search direction specification area) (5) Address (search range specification area) (1) Find What (search data specification area) (1) Find What (search data specification area) This area is used to specify the data to be searched. In the default condition, the character string selected in the window that called this dialog box is displayed. As necessary, input data from the keyboard to change the character string. When searching the memory display area, up to 16 data items can be specified. Delimit each data with a "blank character". When searching the ASCII display area, data of up to 256 characters can be specified. A "blank character" in the data is treated as a blank character. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. (2) Unit (search condition specification area) This area is used to specify the number of bits of the data to be searched in the memory display area. (3) Byte Searches the data as 8-bit data (default). Half Word Searches the data as 16-bit data. Word Searches the data as 32-bit data. Scan Whole Region (search condition specification area) This area is used to specify whether the specified range is fully searched or not. 138 Checked Searches the entire range. Not checked Searches the remaining part of the range (default) User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (4) Direction (search direction specification area) This area is used to specify the direction of the search. (5) Up Forward search. Searches data forward (upward on screen) from the current position of the cursor. Down Backward search (default). Searches data backward (downward on screen) from the current position of the cursor. Address (search range specification area) This area is used to specify the address to be searched. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. Function buttons Find Next Searches the specified data in accordance with a given condition. If the specified character string is found as a result of a search, it is highlighted. To continue searching, click this button again. Set Find Sets the specified condition as the search condition and closes this dialog box. Stop (during search) Stops searching. Cancel Closes this dialog box. This button is displayed as the <Stop> button while data is being searched. Help Opens the Help window. User’s Manual U16525EJ1V0UM 139 CHAPTER 7 WINDOW REFERENCE Memory Fill dialog box This dialog box is used to initialize the memory contents in the Memory window with specified codes. Figure 7-28 Memory Fill Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [Edit] -> [Memory] -> [Fill] from the menu bar. (or press Alt+E, M and F in that order). Explanation of each area The Memory Fill dialog box consists of the following areas: (2) fill code (data specification area) (1) Address (address range specification area) (1) Address (address range specification area) This area is used to specify the memory address range whose contents are to be initialized. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. Input the first address to be initialized and then the last address to be initialized. 140 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (2) fill code (data specification area) This area is used to specify the data with which the memory contents are to be initialized. Up to 16 binary data strings (byte data strings) can be specified. Delimit each data with a "blank character". Function buttons OK Initializes the memory. Stop (during initialization) Stops initialization. While initialization is in progress, the <Cancel> button is replaced by the <Stop> button. Cancel Closes this dialog box. While memory contents are being initialized, this button is replaced by the <Stop> button. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 141 CHAPTER 7 WINDOW REFERENCE Memory Copy dialog box This dialog box is used to copy the memory contents in the Memory window. Figure 7-29 Memory Copy Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [Edit] -> [Memory] -> [Copy] from the menu bar. (or press Alt+E, M and C in that order). Explanation of each area The Memory Copy dialog box consists of the following area: (1) Address (address range specification area) 142 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Address (address range specification area) This area is used to specify the copy source and copy destination addresses. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. From Specify the address range of the copy source. Input the first address of the copy source and then the end address. To Specify the first address of the copy destination. Function buttons OK Copies the memory. Stop (during copying) Stops copying. While copying is in progress, the <Cancel> button is replaced by the <Stop> button. Cancel Closes this dialog box. While copying is in progress, this button is replaced by the <Stop> button. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 143 CHAPTER 7 WINDOW REFERENCE Memory Compare dialog box This dialog box is used to compare the memory contents in the Memory window. Figure 7-30 Memory Compare Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [Edit] -> [Memory] -> [Compare] from the menu bar. (or press Alt+E, M and P in that order). Explanation of each area The Memory Compare dialog box consists of the following area: (1) Address (comparison range specification area) 144 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Address (comparison range specification area) This area is used to specify the comparison source address and comparison destination address. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. Mem1 Specify the address range of the comparison source. Input the first address of the comparison source and then the end address. Mem2 Specify the first address of the comparison destination. Function buttons OK Compares the memory. If no difference is found as a result of comparison, a confirmation dialog box is displayed. If a difference is found, Memory Compare Result dialog box is opened. Figure 7-31 Confirmation Dialog Box Clicking the <OK> button ends memory comparison. Stop (during comparison) Stops memory comparison. While comparison is in progress, the <Cancel> button is replaced by the <Stop> button. Cancel Closes this dialog box. While comparison is in progress, this button is replaced by the <Stop> button. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 145 CHAPTER 7 WINDOW REFERENCE Memory Compare Result dialog box Displays the result of comparing the memory. This dialog box is displayed if any difference is found in the memory contents when the memory has been compared in Memory Compare dialog box. Figure 7-32 Memory Compare Result Dialog Box This section explains the following items: • Explanation of each area • Function buttons Explanation of each area The Memory Compare Result dialog box consists of the following area: (1) Mem1, Mem2 (comparison result display area) 146 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Mem1, Mem2 (comparison result display area) This area displays the results of comparing the memory. Only differences that have been found as a result of comparison are displayed. Mem1 Addr Displays a comparison source address in which a difference has been found. Memory Displays the data in which a difference has been found. Left: Comparison source data Right: Comparison destination data Mem2 Addr Displays the comparison destination address at which a difference has been found. Function buttons Close Closes this dialog box. Help Opens the Help window. User’s Manual U16525EJ1V0UM 147 CHAPTER 7 WINDOW REFERENCE DMM dialog box This dialog box is used to set addresses and data for DMM (Dynamic Memory Modification). DMM is used to rewrite the memory contents while the user program is being executed. Because this function is implemented by software emulation, however, the user program under execution is temporarily stopped and then executed again. Caution1 Nothing can be written to the internal flash memory, during user program execution. Caution2 The following points must be noted when using the DMM function. - If data is written to an address for which a software break is set, the program may not run correctly. - If the program is stopped immediately before rewriting the memory because a break event is generated, the generated break event is invalid because program execution is resumed, regardless of the break event. - Verify check is always invalid. Even if writing has failed, a verify error is not generated. Figure 7-33 DMM Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [Edit] -> [Memory] -> [Modify] from the menu bar. (or press Alt+E, M and M in that order). • Click the <Modify> button in the Memory window. 148 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Explanation of each area The DMM dialog box consists of the following areas: (2) Data (data setting area) (3) Data Size (data size setting area) (1) Address (address setting area) (1) Address (address setting area) This area is used to specify the address to which data is to be written. An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. (2) Data (data setting area) This area is used to specify the data to be written to the memory address specified in Address. One binary data string can be specified at one time. Specify the data size in Data Size. Specify the data size in Data Size. The default radix for inputting a numeric value is hexadecimal. (3) Data Size (data size setting area) This area is used to specify the size of the data to be written. Byte Writes data specified in Data as 8-bit data. Half Word Writes data specified in Data as 16-bit data. Word Writes data specified in Data as 32-bit data. Function buttons OK Writes the data. Cancel Closes this dialog box. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 149 CHAPTER 7 WINDOW REFERENCE Watch window This window is used to display and change specified data. The result of updating and rewriting data in this window will be reflected in the Memory window. This window can also display wide-ranging data (such as global variables and public symbols) in real time even during program execution, in the same way as the Memory window. To set a breakpoint for read/write access to a variable can be performed by a single action from the menu that is displayed by clicking the right mouse button. Caution If a local variable and a global variable exist with the same name, the local variable takes priority. Figure 7-34 Watch Window This section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons • Related operations • To add/delete displayed data (variable) • To change data on the selected line • To temporarily display a data (variable) value • To display/change a local variable value • To set a breakpoint for read/write access to a variable • To change displayed radix/size 150 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Opening This window can be opened as follows: • Click the Wch button. Select [Browse] -> [Watch] from the menu bar, (or press Alt+B, and W in that order). Select data in the Source window or Assemble window, • Select [View] -> [View Watch] from the menu bar, (or press Alt+ V, and I in that order), or click the <Watch> button. In the Quick Watch dialog box or Add Watch dialog box dialog box, • Click the <Add> button. Explanation of each area The Watch window consists of the following areas: (2) Right field (data value display/setting area) (1) Left field (symbol name display area) (1) Left field (symbol name display area) This area is used to display variable names, symbol names and types, and tag names of structures or unions. Refer to "Name (symbol specification area)" in the Add Watch dialog box for details on the displayed contents. '+' is prefixed to the displayed arrays, pointer variables, and structures or unions. These variables are expanded and displayed as follows when they are double-clicked: Array All the elements of the variable are displayed in accordance with the type of the array variable. Pointer variable The data indicated by the pointer is displayed. Structure/union All the members of the structure/union are displayed in accordance with the type of the member variable. If a structure or union is defined in the structure or union, the structure name or union name of the internal structure or union is also displayed. The internal structure or union can be also expanded by using '+'. User’s Manual U16525EJ1V0UM 151 CHAPTER 7 WINDOW REFERENCE '+' of the variable that has been expanded and displayed changes to '-'. If the variable is doubleclicked in this status, the expanded display is canceled. Expanded display can be also specified or canceled by selecting a variable with the arrow keys and then pressing the Enter key. If an access breakpoint is set for a variable or a symbol in the Watch window, the symbol name display area is highlighted in gold. Reference If an array has too many variables and takes too long to expand, a warning message is displayed. (2) Right field (data value display/setting area) This area is used to display and change data values. A value is updated when execution is stopped. To save a value, select [File ] -> [Save As...] from the menu bar when the Save window is the current window. This area is blank if getting data has failed. '?' is displayed for data that has been invalidated because of a change in the scope or optimized compiling. The contents of the change are written into the target memory when the Enter key is pressed. The previous value can be canceled by the ESC key. The display format is as follows: Table 7-16 Data Display Format (Watch-Related) Display Data Contents Integer Hexadecimal (0xxxxx) Decimal (xxxx) Octal (0xxxx) Binary (0bxxxx) Enumeration type Member name If scope is specified Displayed in accordance with specified scope Floating-point type Single precision/double precision supported The input/display format is as follows: [ + | - ] inf [ + | - ] nan [ + | - ] integer e [ + | - ]exponent [ + | - ] integer.fraction [e [ + | - ]exponent The size and radix of a data value can be specified on the [View] menu for each variable. However, the display size cannot be selected if the display size is fixed, such as for variables in C or bit symbols or registers of the assembler. 152 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE If [View] -> [Adaptive] or [View] -> [Proper] from the menu bar is selected, the size and radix specified in the Debugger Option dialog box are used for display (refer to "To change displayed radix/size"). Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. Break when Access to this Variable Creates a break event that occurs if the selected variable is accessed for read/write. Break when Write to this Variable Creates a break event that occurs if the selected variable is accessed for write. Break when Read from this Variable Creates a break event that occurs if the selected variable is accessed for read. Clear Deletes the break event corresponding to the selected variable. Event? Displays the event information of the line at the cursor position or the selected variable. If an event is set, Event dialog box is opened. Change Watch... Changes the selected data. Delete Watch Deletes the selected watch point from the window. Bin Displays the selected line in binary numbers. Oct Displays the selected line in octal numbers. Dec Displays the selected line in decimal numbers. Hex Displays the selected line in hexadecimal numbers. String Displays the selected line as a character string. Proper Displays the selected line as the default value of each variable. Symbols are displayed in accordance with the setting of Debugger Option dialog box (default). Byte Displays the selected line in 8-bit units. Half Word Displays the selected line in 16-bit units. Word Displays the selected line in 32-bit units. Adaptive Displays the selected line as the default value of each variable. Only this item is valid for a symbol in C language. Symbols in assembly language are displayed in accordance with the setting of Debugger Option dialog box (default). Up Moves the selected line one line up. Down Moves the selected line one line down. User’s Manual U16525EJ1V0UM 153 CHAPTER 7 WINDOW REFERENCE Function buttons Add... Opens the Add Watch dialog box. If data is specified and the <Add...> button is clicked in the Add Watch dialog box, the specified data is added to the Watch window. Delete Deletes the specified data from the Watch window. The DEL key performs the same operation. Up Moves the selected data one line up. Down Moves the selected data one line down. Refresh Updates the contents of the window with the latest data. Close Closes this window. Related operations To add/delete displayed data (variable) Addition method (any of the following) • Select a variable name or symbol name and click the <Watch> button in the Source window or Assemble window. • Select a variable name or symbol name in the Source window or Assemble window, and drag it to the Watch window. • Specify a variable name or symbol name and click the <Add> button in the Quick Watch dialog box or Add Watch dialog box. • Select a variable name or symbol name and select [View] menu -> [Add Watch...] in the Source window or Assemble window. Deletion method • Click a variable name or symbol name (two or more variable or symbol names can be selected using the Shift or Ctrl key), and click the <Delete> button. A line with an expanded hierarchy, such as the elements of an array, and members of structures and unions cannot be changed. To change data on the selected line To change data (variables), select a line to be changed in the Watch window and select right-click menu -> [Change Watch...]. The Change Watch dialog box will be opened to change the data. A line with an expanded hierarchy, such as the elements of an array, and members of structures and unions cannot be deleted. To temporarily display a data (variable) value A data (variable) value can be temporarily displayed in the following two ways: To display using the balloon watch function Select data (a variable name) in the Source window or Assemble window. Then place the mouse cursor on the selected character string. The value of the selected data will be displayed. To display in the Quick Watch dialog box Select data (a variable name) in the Source window or Assemble window. Then click the <Quick...> 154 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE button. The value of the selected data will be displayed in the Quick Watch dialog box. To display/change a local variable value A local variable value can be checked or changed in the Local Variable window, which is opened when the Loc button is clicked. In this window, the local variable in the current function is automatically displayed and the displayed variable cannot be added or deleted. To change a local variable value, move the cursor to the local variable value display/changing area on the window and write a value in this area directly from the keyboard. To determine the displayed contents, use the Enter key. To cancel, use the ESC key. To set a breakpoint for read/write access to a variable Select a variable in the Watch window and select [Break when Access to this Variable], [Break when Write to this Variable] or [Break when Read from this Variable] from the right-click menu. In this way, a hardware break event will be created in the valid status in accordance with the selected item. Whether the event has been correctly created can be confirmed on the Event Manager. To change displayed radix/size Changing each data (variable) at any time Select a data (variable) name to be changed in the Watch window or Quick Watch dialog box, and select the radix and size from the right-click menu. Specifying default condition Adaptive (when display size is specified) or Proper (when display radix is specified) for watching a symbol that specifies a default value can be set as the default assumption. This is done in the Watch Default area of the Debugger Option dialog box, which is opened when [Option] -> [Debugger Option...] is selected from the menu bar. The size specified under Size is displayed when Adaptive is specified, and the radix specified under Radix is displayed when Proper is specified. User’s Manual U16525EJ1V0UM 155 CHAPTER 7 WINDOW REFERENCE Quick Watch dialog box This dialog box is used to temporarily display or change specified data. Figure 7-35 Quick Watch Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [View] -> [Quick Watch...] (or press Alt+V, and Q in that order). • Click the <Quick...> button in Source window. (or press Ctrl+W). • Click the <Quick...> button in Assemble window. (or press Ctrl+W). Explanation of each area The Quick Watch dialog box consists of the following areas: (2) Symbol name display area (3) Data value display/setting area (4) Display radix selection area (upper left field) (5) Display size selection area (second upper left field) (6) Number (display number specification area) (1) Name (symbol specification area) 156 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Name (symbol specification area) This area is used to specify the data to be displayed. In the default condition, the character string selected in the window that called this dialog box is displayed. As necessary, input data from the keyboard to change the character string. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. If the contents of Name have been changed, the data specified in Name can be displayed in the field below by clicking the <View> button. (2) Symbol name display area This area is used to display the variable name and the symbol name. The displayed contents are the same as those of Name (symbol specification area) in the Add Watch dialog box. (3) Data value display/setting area This area is used to display and change data values. The displayed contents and display method are the same as those of Watch window. The displayed contents are the same as those of Right field (data value display/setting area) in the Watch window. (4) Display radix selection area (upper left field) This area is used to select the display radix. The display radix of the data name selected in the symbol name display area will be changed. Proper Variable The default value of each variable is displayed. Symbol Displays data with the radix set in Debugger Option dialog box. Hex Displays data in hexadecimal numbers (0xxxxx) User’s Manual U16525EJ1V0UM 157 CHAPTER 7 WINDOW REFERENCE (5) Dec Displays data in decimal numbers (xxxx) Oct Displays data in octal numbers (0xxxx) Bin Displays data in binary numbers (0bxxxx) String Displays character strings. Display size selection area (second upper left field) This area is used to select the display size. The display size of the data selected in the symbol name display area will be changed. If the display size is fixed, such as when a variable in C or register is to be displayed, it cannot be changed. (6) Adaptive Variable The default value of each variable is displayed. Symbol Displays data with the size set in Debugger Option dialog box. Byte Displays data in 8 bits. Half Word Displays data in 16 bits. Word Displays data in 32 bits. Number (display number specification area) This area is used to specify the number of data to be displayed. Specify blank or a number of 1 to 256. If this area is blank, data is displayed as a simple variable. If a number of 1 or more is specified, data is displayed as an array variable. If an array variable is displayed, '+' is prefixed to the data. By double-clicking this '+', all the elements of the data are expanded and displayed in accordance with the type of the data ('-' is prefixed to the expanded data. If this '-' is double-clicked, the expanded display is canceled). If the number of data to be displayed is fixed, such as when a variable in C or register is to be displayed, the specified number of data is invalid. Function buttons 158 View Displays the data specified in Name in the field below. Add Displays the data specified in Name to the Watch window. Close Closes this dialog box. Data that has not actually been written to the target will be canceled. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Add Watch dialog box This dialog box is used to register data to be displayed in the Watch window. Multiple data with the same symbol name can be registered. Figure 7-36 Add Watch Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [View] -> [Add Watch...] from the menu bar (or press Alt+V, and W in that order). • Click the <Add> button in Watch window. Explanation of each area The Add Watch dialog box consists of the following areas: (2) Radix (display radix selection area) (3) Size (display size specification area) (4) Number (display number specification area) (1) Name (symbol specification area) User’s Manual U16525EJ1V0UM 159 CHAPTER 7 WINDOW REFERENCE (1) Name (symbol specification area) This area is used to specify data to be added to the Watch window. In the default condition, the character string selected in the window that called this dialog box is displayed. As necessary, input data from the keyboard to change the character string. This area is blank if no character string is selected. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. The format in which a variable can be input and how a variable is handled when a scope is specified are as follows: • Variable Name Variable Name Variable Name Variable expression[Constant value | Variable Name] Elements of array Variable expression. Member name Entity members of structure/union Variable expression -> Member name Members of structure/union indicated by pointer *Variable expression Value of pointer variable &Variable expression Address where variable is located • Register name • IOR name, IOR bit name • Label and address of immediate value • Register name.bit • Label name.bit , address of immediate value.bit • Specification of scope Table 7-17 Scope Specification 160 How a Variable Is Handled When a Scope Is Specified Program name File name Function name Variable Name prog$file#func#var prog file func var prog$file#var prog file Global var prog$func#var prog Global func var prog$var prog Global Global var file#func#var Current file func var file#var Current file Global var func#var Current Current func var var Current Current Current var User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (2) Radix (display radix selection area) This area is used to change the radix of the data to be displayed. (3) Proper Variable The default value of each variable is displayed. Symbol Displays data with the radix set in Debugger Option dialog box. Hex Displays data in hexadecimal numbers (0xxxxx) Dec Displays data in decimal numbers (xxxx) Oct Displays data in octal numbers (0xxxx) Bin Displays data in binary numbers (0bxxxx) String Displays character strings. Size (display size specification area) This area is used to change the size of data to be displayed. If the display size is fixed, such as when a variable in C or a bit symbol or register of the assembler is to be displayed, it cannot be changed. (4) Adaptive Variable The default value of each variable is displayed. Symbol Displays data with the size set in Debugger Option dialog box. Byte Displays data in 8 bits. Half Word Displays data in 16 bits. Word Displays data in 32 bits. Number (display number specification area) This area is used to specify the number of data to be displayed. Specify blank or a number of 1 to 256. If this area is blank, data is displayed in Watch window as a simple variable. If a number of 1 or more is specified, data is displayed in the Watch window as an array variable. The maximum number of lines that can be displayed in the Watch window is 10,000. If an array variable is displayed, '+' is prefixed to the data. By double-clicking this '+', all the elements of the data are expanded and displayed in accordance with the type of the data ('-' is prefixed to the expanded data. If this '-' is double-clicked, the expanded display is canceled). If the number of data to be displayed is fixed, such as when a variable in C or register is to be displayed, the number of data is invalid in the Watch window even if it has been changed. User’s Manual U16525EJ1V0UM 161 CHAPTER 7 WINDOW REFERENCE Function buttons 162 Add Adds the specified data to the Watch window. The dialog box remains open. OK Adds the specified data to the Watch window. Closes this dialog box. Cancel Closes this dialog box. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Change Watch dialog box This window is used to change the data on a line selected in the Watch window. A line with an open hierarchy, such as the elements of an array, and members of structures and unions cannot be changed. When watch data is changed, the contents of the selected line are replaced with the new data. The symbol name can be changed even if it results in duplication of a name already in use with existing data. Figure 7-37 Change Watch Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: When the Watch window is open or a line is selected • Select [View] -> [Change Watch...] from the menu bar (or press Alt+V, and G in that order). Explanation of each area The Change Watch dialog box consists of the following areas: (2) Radix (display radix selection area) (3) Size (display size specification area) (4) Number (display number specification area) (1) Name (symbol specification area) User’s Manual U16525EJ1V0UM 163 CHAPTER 7 WINDOW REFERENCE (1) Name (symbol specification area) This area is used to change a symbol name. By displaying the input history, the contents previously input can be reused. Up to 16 input histories can be recorded. The format in which a symbol name can be input is the same as that of Name (symbol specification area) in the Add Watch dialog box. (2) Radix (display radix selection area) This area is used to change the radix of data to be displayed. (3) Proper Variable The default value of each variable is displayed. Symbol Displays data with the radix set in Debugger Option dialog box. Hex Displays data in hexadecimal numbers (0xxxxx) Dec Displays data in decimal numbers (xxxx) Oct Displays data in octal numbers (0xxxx) Bin Displays data in binary numbers (0bxxxx) String Displays character strings. Size (display size specification area) Displays and modifies variables. If the display size is fixed, such as when a variable in C or register is to be displayed, it cannot be changed. 164 Adaptive Variable The default value of each variable is displayed. Symbol Displays data with the size set in Debugger Option dialog box. Byte Displays data in 8 bits. Half Word Displays data in 16 bits. Word Displays data in 32 bits. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (4) Number (display number specification area) This area is used to specify the number of data to be displayed. Specify blank or a number of 1 to 256. If this area is blank, data is displayed in Watch window as a simple variable. If a number of 1 or more is specified, data is displayed in the Watch window as an array variable. The maximum number of lines that can be displayed in the Watch window is 10,000. If an array variable is displayed, '+' is prefixed to the data. By double-clicking this '+', all the elements of the data are expanded and displayed in accordance with the type of the data ('-' is prefixed to the expanded data. If this '-' is double-clicked, the expanded display is canceled). f the number of data to be displayed is fixed, such as when a variable in C or register is to be displayed, the number of data is invalid in the Watch window even if it has been changed. Function buttons Add Cannot be selected. OK Replaces the registration contents currently selected with the specified data, and then closes this dialog box. Closes this dialog box. Cancel Closes this dialog box. Restore Restores the input data to the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 165 CHAPTER 7 WINDOW REFERENCE Local Variable window This window is used to display and change the local variable in the current function. This window automatically displays the local variable in the current function. It is linked with the jump function of the Stack Trace window, and displays the local variable in the function jumped when jumping to the Source window. Variables cannot be added or deleted. Figure 7-38 Local Variable Window This section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons Opening This window can be opened as follows: • Click the Loc button. • Select [Browse] -> [Local Variable] from the menu bar, (or press Alt,+B, and L in that order). Explanation of each area The Local Variable window consists of the following areas: (2) Right field (local variable value display/setting area) (1) Left field (local variable name display area) 166 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Left field (local variable name display area) This area displays local variable name. Auto, internal Static, and Register variables can be displayed. The display format is the same as that of the Watch window. This area cannot be edited directly. (2) Right field (local variable value display/setting area) This area displays local variable values. The display format of the variable value is the same as that of the Watch window. The display radix of variables can be switched by the menu selection in accordance with each variable. The new value is written into the target memory when the Enter key is pressed. The previous value can be canceled by the ESC key. Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. Add Watch Registers a selected character string to the Watch window. Opens the Add Watch dialog box. Bin Displays the selected line in binary numbers. Oct Displays the selected line in octal numbers. Dec Displays the selected line in decimal numbers. Hex Displays the selected line in hexadecimal numbers. User’s Manual U16525EJ1V0UM 167 CHAPTER 7 WINDOW REFERENCE String Displays the selected line as a character string. Proper Displays the selected line as the default value of each variable. Symbols are displayed in accordance with the setting of Debugger Option dialog box (default). Function buttons 168 Refresh Updates the contents of the window with the latest data. Close Closes this window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Stack Trace window This window is used to display or change the current stack contents of the user program. From this window, you can also jump to the Source window, Assemble window, and Memory window corresponding to the stack contents. Caution The stack trace display function may not operate correctly if there is a function that does not create a stack frame. In addition, [ERROR] may be displayed during prologue or epilogue processing of a function. Figure 7-39 Stack Trace Window This section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons Opening This window can be opened as follows: • Click the Stk button. • Select [Browse] -> [Stack Trace] from the menu bar, (or press Alt+B , and K in that order). User’s Manual U16525EJ1V0UM 169 CHAPTER 7 WINDOW REFERENCE Explanation of each area The Stack Trace window consists of the following areas: (2) Center field (stack frame contents display area) (3) Right field (stack contents display/setting area) (1) Left field (stack frame number display area) (1) Left field (stack frame number display area) This area assigns numbers to and displays the stack contents. A stack frame number is a natural number starting from 1. The shallower the nesting of the stack, the higher the number. This means that a function having stack number one higher than that of a certain function is the function that calls the certain function. (2) Center field (stack frame contents display area) This area displays the stack frame contents. It displays function names or local variable names. Note, however, that this area cannot be directly edited. If the stack contents consist of a function, they are displayed as follows: program name$file name#function name (argument list) #line number If this line is double-clicked, the operation will be the same as jumping to the Source window of the jump function (i.e., the local variable in the function to which execution has jumped will be displayed in the Local Variable window). If the function has a local variable, the local variable will be displayed on the next and subsequent lines. If the stack contents consist of a local variable, its type and name are displayed. These are displayed in the same manner as in the Watch window. Note that the internal Static and Register variables are not displayed. 170 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (3) Right field (stack contents display/setting area) This area is used to display or change the stack contents. '-' or a local variable value is displayed. If the stack contents are a function '-' is displayed and the function cannot be changed. If the stack contents are a local variable, the variable value is displayed in the same manner as in the Watch window. The display radix of variables can be switched by the menu selection in accordance with each variable. A variable value can be changed. The new value is written into the target memory when the Enter key is pressed. The previous value can be canceled by the ESC key. This area is used as the jump source area of the jump function. Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. Bin Displays the selected line in binary numbers. Oct Displays the selected line in octal numbers. Dec Displays the selected line in decimal numbers. Hex Displays the selected line in hexadecimal numbers. String Displays the selected line as a character string. Proper Displays the selected line as the default value of each variable. Symbols are displayed in accordance with the setting of Debugger Option dialog box (default). Source Text Displays the corresponding source text and source line from the jump destination address specified by the data value at the cursor position (the local variable in the function to which you have jumped is displayed in the Local Variable window). If no line information exists at the jump destination address, however, you cannot jump. Opens the Source window. If an active Source window is open, that window is displayed in the forefront (so that it can be manipulated). User’s Manual U16525EJ1V0UM 171 CHAPTER 7 WINDOW REFERENCE Assemble Disassembles and displays starting from the jump destination address specified by the data value at the cursor position. Opens the Assemble window. If an active Assemble window is open, that window is displayed in the forefront (so that it can be manipulated). Memory Displays the memory contents starting from the jump destination address specified by the data value at the cursor position. Opens the Memory window. If an active Memory window is open, that window is displayed in the forefront (so that it can be manipulated). Function buttons 172 Refresh Updates the contents of the window with the latest data. Shrink<<< Collapses the local variable list of the selected function. Expand>>> Displays the local variable list of the selected function. Close Closes this window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Register window This window is used to display and change the contents of registers (program registers and system registers). The register to be displayed in this window can be selected in the Register Select dialog box. Figure 7-40 Register Window This section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons • Related operations • To change a register value • To select the register to be displayed Opening This window can be opened as follows: • Click the Reg button. • Select [Browse] -> [Register] from the menu bar, (or press Alt+B, and R in that order). User’s Manual U16525EJ1V0UM 173 CHAPTER 7 WINDOW REFERENCE Explanation of each area The Register window consists of the following areas: (2) Lower left field (system register display area) (1) Upper left field (program register display area) (1) Upper left field (program register display area) This area is used to display or change the contents of program registers. The new value is written into the target memory when the Enter key is pressed. The previous value can be canceled by the ESC key. This area is also used as a jump pointer of the jump function. (2) Lower left field (system register display area) This area is used to display or change the contents of system registers. The new value is written into the target memory when the Enter key is pressed. The previous value can be canceled by the ESC key. If the name of a register with '+' prefixed is double-clicked, the names and values of its flags are displayed, and '+' changes to '-'. This '+' can be also changed to '-' by selecting a register name with the arrow keys and pressing the Enter key. This area is also used as a jump pointer of the jump function. Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. 174 Add Watch Registers a selected character string to the Watch window. Opens the Add Watch dialog box. Bin Displays the selected line in binary numbers. Oct Displays the selected line in octal numbers. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Dec Displays the selected line in decimal numbers. Hex Displays the selected line in hexadecimal numbers (default). Pick Up Displays only the registers selected in Register Select dialog box. Checked: Displays only the selected register. Not checked: Displays all the registers (default). Select... Opens the Register Select dialog box. Function buttons Refresh Updates the contents of the window with the latest data. Close Closes this window. Related operations To change a register value To change the value of a register, move the cursor to the system register display area or program register display area in the window, and directly write a value from the keyboard. Press the return key to set the new value. To cancel the change, press the ESC key. To select the register to be displayed Use the Register Select dialog box, which can be opened by selecting right-click menu -> [Select...] in the Register window. User’s Manual U16525EJ1V0UM 175 CHAPTER 7 WINDOW REFERENCE Register Select dialog box This dialog box is used to select registers that are not displayed in the Register window. Figure 7-41 Register Select Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: When Register window is the current window, • Select [View] -> [Select...] from the menu bar (or press Alt+V, and E in that order). Explanation of each area The Register Select dialog box consists of the following area: (1) Display, No Display (display register selection area) 176 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Display, No Display (display register selection area) This area is used to select registers that are displayed in the Register window, and those that are not. Display Registers displayed in the Register window. No Display Registers not displayed in the Register window. To display or not display a register in the Register window, select a register name from these lists, and click the <<<Show> or <Hide>>> button. To display all the registers, click the <<<Show All> button. To not display any of the registers, click the <<<Hide All> button. The function of each button is as follows: << Show Moves the register selected from the No Display list to Display. Hide >> Moves the register selected from the Display list to No Display. << Show All Moves all registers to Display. Hide All >> Moves all registers to No Display. When selecting a register from the lists, two or more registers can be selected by clicking any of the above buttons while holding down the Ctrl or Shift key. Function buttons OK Reflects the selection in this dialog box in Register window and closes this dialog box. Cancel Cancels the changes and closes this dialog box. Restore Restores the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 177 CHAPTER 7 WINDOW REFERENCE IOR window This window is used to display and change the contents of peripheral I/O registers and the I/O ports that have been registered in the Add I/O Port dialog box. Note, however, that the values of read-only peripheral I/O registers and I/O ports cannot be changed. In addition, the peripheral I/O registers and I/O ports that cause the device to operate when they are read are read-protected and therefore cannot be read. To read these registers, select a register, and select and execute [Compulsion Read] from the right-click menu. Reference If the device supports programmable I/O registers and a programmable I/O area has been set in the Configuration dialog box, the programmable I/O registers are also displayed. If the value of an I/O port address is defined, the I/O port name is displayed in light color. Figure 7-42 IOR Window This section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons • Related operations • To change a peripheral I/O register value • To select a peripheral I/O register or I/O port to be displayed • To change the display sequence • To change the display radix 178 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE • To add, change the contents of, and delete a user-defined I/O port • To change the display start position Opening This window box can be opened as follows: • Click the IOR button. • Select [Browse] -> [I/O Register] from the menu bar (or press Alt,+B, and G in that order). Explanation of each area The IOR window consists of the following areas: (2) Attribute (attribute display area) (3) Value (peripheral I/O register contents display area) (1) Name (peripheral I/O register name display area) (1) Name (peripheral I/O register name display area) This area displays the names of peripheral I/O registers and I/O ports. When the V850E is used, it also displays the programmable peripheral I/O registers and expansion peripheral I/O registers. If the value of an I/O port address is not defined, the I/O port name displayed in light color. (2) Attribute (attribute display area) User’s Manual U16525EJ1V0UM 179 CHAPTER 7 WINDOW REFERENCE This area displays the read/write attributes, access types, and absolute addresses of the peripheral I/O registers and I/O ports. when the bit peripheral I/O register is displayed, bit-offset value is also displayed. It can be specified whether this area is displayed or not, by selecting [View] -> [Attribute] from the menu bar. As an attribute, the following contents are displayed. Read/Write Attribute R Read only W Write only R/W Read/write * Register that is read via an emulation register to prevent the device from operating when this register is read. To read this attribute directly from a peripheral I/O register, execute [View] -> [Compulsion Read] from the menu bar. Even a write-only peripheral I/O register can also be read via an emulation register. However, some devices do not support this function. Access Type (3) 1 Can be accessed in bit units. 8 Can be accessed in byte units. 16 Can be accessed in halfword units. 32 Can be accessed in word units. Value (peripheral I/O register contents display area) This area is used to display and change the contents of a peripheral I/O register and I/O port. The contents are displayed differently as follows, depending on the attribute: Black Display Read only or read/write -- Write only ** Value changes if read The new value is written into the target memory when the Enter key is pressed. The previous value can be canceled by the ESC key. The value of read-protected peripheral I/O registers and I/O ports can be read by selecting right-click menu -> [Compulsion Read]. 180 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. Move... Moves the display position. Opens the Address move dialog box. Add Watch... Registers a selected character string to the Watch window. Opens the Add Watch dialog box. Add I/O Port... Adds user-defined I/O ports. Opens the Add I/O Port dialog box. Bin Displays the selected line in binary numbers. Oct Displays the selected line in octal numbers. Dec Displays the selected line in decimal numbers. Hex Displays the selected line in hexadecimal numbers (default). Sort By Name Displays in alphabetical order. Sort By Address Displays in address order (default). Unsort Does not sort. Attribute Displays or does not display an attribute area (Attribute). Checked: Displayed (default) Not checked: Not displayed Pick Up Displays only the registers selected in IOR Select dialog box. Checked: Displays only the selected register. Not checked: Displays all the registers (default). Select... Opens the IOR Select dialog box. Compulsion Read Forcibly reads the peripheral I/O registers that are disabled from being read because their values will be changed, or the data of the I/O ports and I/O protect area added in Add I/O Port dialog box. Function buttons Refresh Updates the contents of the window with the latest data. Close Closes this window. User’s Manual U16525EJ1V0UM 181 CHAPTER 7 WINDOW REFERENCE Related operations To change a peripheral I/O register value To change the contents of a peripheral I/O register or I/O port, move the cursor to the Value area on the window, and write a value directly from the keyboard. Press the return key to set the new value. To cancel the change, press the ESC key. Note that the values of read-only peripheral I/O registers and I/O ports cannot be changed. To select a peripheral I/O register or I/O port to be displayed Use the IOR Select dialog box, which can be opened by selecting right-click menu -> [Select...] in the IOR window. To change the display sequence The display sequence can be changed by selecting right-click menu -> [Sort By Name/Sort By Address/Unsort]. To change the display radix Select the line whose radix is to be changed, and select right-click menu -> [Bin/Oct/Dec/Hex]. To add, change the contents of, and delete a user-defined I/O port To manipulate an I/O port, use the Add I/O Port dialog box, which can be opened by selecting rightclick menu -> [Add I/O Port...] in the IOR window. To change the display start position Use the Address move dialog box, which can be opened by selecting right-click menu -> [Move...] in the Assemble window. 182 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE IOR Select dialog box This dialog box is used to select peripheral I/O registers and I/O ports that are not displayed the IOR window. It is also used to specify the sequence in which registers and ports are displayed. Figure 7-43 IOR Select Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: When IOR window is the current window • Select [View] -> [Select...] from the menu bar (or press Alt+V, and E in that order). Explanation of each area The IOR Select dialog box consists of the following areas and buttons: (2) Arrange (display sequence specification button) (3) Sort by (No Display list display sequence change button) (1) Display, Pick Up, No Display (display peripheral I/O register selection area) User’s Manual U16525EJ1V0UM 183 CHAPTER 7 WINDOW REFERENCE (1) Display, Pick Up, No Display (display peripheral I/O register selection area) This area is used to select registers and I/O ports that are displayed or not displayed on the IOR window. Display Registers and I/O ports are displayed in the IOR window No Display Registers and I/O ports are not displayed in the IOR window To display or not display a register or I/O port in the IOR window, select the name of the register or I/O port from these lists, and click the <<<Show> or <Hide>>> button. To display all the peripheral I/O registers, click the <<<Show All> button; to not display any of the registers, click the <Hide All>>> button. << Show Moves the register or I/O port selected from the No Display list to Display. Hide >> Moves the register or I/O port selected from the Display list to No Display. << Show All Moves all the registers and I/O ports to Display. Hide All >> Moves all the registers and I/O ports to No Display. When selecting a peripheral I/O register from the list, two or more registers can be selected by clicking any of the above buttons with the Ctrl or Shift key held down. (2) Arrange (display sequence specification button) This button sets the sequence in which the registers and I/O ports are displayed in the Display list. A peripheral I/O register or I/O port selected in the Display list can be moved to the top of the list by pressing the <Top> button, or to the bottom of the list by pressing the <Bottom> button. The <Up> button moves the register or port one line up. The <Down> button moves the register or port one line down. 184 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (3) Top Moves the selected peripheral I/O register or I/O port to the top of the list. Up Moves the selected peripheral I/O register or I/O port one line up. Down Moves the selected peripheral I/O register or I/O port one line down. Bottom Moves the selected peripheral I/O register or I/O port to the bottom of the list. Sort by (No Display list display sequence change button) This button selects the sequence in which peripheral I/O registers and I/O ports are displayed in the No Display list. Pressing the <Name> button sorts the registers and ports into alphabetical order. The <Address> button sorts them into address order. Name Displays in alphabetical order. Address Displays in address order. Function buttons OK Reflects the selection in this dialog box in IOR window and closes this dialog box. Cancel Cancels the changes and closes this dialog box. Restore Restores the original status. Help Opens the Help window. User’s Manual U16525EJ1V0UM 185 CHAPTER 7 WINDOW REFERENCE Add I/O Port dialog box This dialog box is used to register an I/O port to be added to the IOR window. Figure 7-44 Add I/O Port Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [Option] ->[Add I/O Port...] from the menu bar (or press Alt+O, and P in that order). Explanation of each area The Add I/O Port dialog box consists of the following areas: (2) Name: (I/O port name specification area) (3) Address: (I/O port address specification area) (4) Access (access size specification area) (5) Read / Write (access attribute specification area) (1) I/O Port List: (I/O port selection area) 186 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) I/O Port List: (I/O port selection area) This area lists the I/O ports currently registered. If a new I/O port is registered, it is added to this list. In addition, an I/O port already registered can be selected and changed or deleted. (2) Name: (I/O port name specification area) This area is used to specify an I/O port name to be added. An I/O port name can be up to 15 characters long. (3) Address: (I/O port address specification area) This area is used to specify the address of the I/O port to be added. Only an address in one of these areas can be specified: Target area, IOR area An address can be also specified by a symbol or expression (refer to "Table 7-10 Specifying Symbols"). The default radix for inputting a numeric value is hexadecimal. (4) Access (access size specification area) This area is used to specify the access size of the I/O port to be added. Byte 8 bits (default) Half Word 16 bits Word 32 bits User’s Manual U16525EJ1V0UM 187 CHAPTER 7 WINDOW REFERENCE (5) Read / Write (access attribute specification area) This area is used to specify the access attribute of the I/O port to be added. In the default condition, all the attributes are not checked (i.e., the I/O port can be both read and written). Read Only Read only Write Only Write only Read Protect Read-protected Function buttons 188 OK Reflects the result of addition in IOR window and closes this dialog box. Cancel Cancels changes and closes this dialog box. Restore Restores the original status. Help Opens the Help window. Add Adds an I/O port of the specified address. Change Changes the setting of the I/O port selected in I/O Port List. Delete Deletes the I/O port selected in I/O Port List. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Event Manager This window is used to display, enables/disables, and delete each event. It is also used to register the various conditions events and manage the event conditions for setting them. Up to 256 conditions can be registered as event conditions or various event conditions. However, the number of event conditions that can be used (enabled) at the same time is limited as follows: Table 7-18 Maximum Number of Valid Events for Each Event Condition Event Event link Connected IE Execution IE-V850E1-CD-NW Nx85ET(RCU0+TEU+ TRCU) 10a Nx85E901(RCU0), RCU1 2c Access 4b Break condition 1 14 1d 2c a. Two events before execution (range cannot be specified) and eight events after execution (four events if a range is specified) b. Two events when a range specified c. The address range of the before execution cannot be specified. d. Can be set only in Phase 1 and Phase 2 (must always be set in two stages), without pass count and Disable condition specification. Figure 7-45 Event Manager The section explains the following items: • Opening • Explanation of each area • Functions often used (right-click menu) • Function buttons User’s Manual U16525EJ1V0UM 189 CHAPTER 7 WINDOW REFERENCE • Related operations • To save/restore event information • To enable/disable an event • To change the display sequence of event icons • To display details of event condition • To delete an event • To manage a software break event • To create an event condition • To create an event link condition • To set an event condition and event link condition as various event condition Opening This window can be opened as follows: • Click the Mgr button. • Select [Event] -> [Event Manager] from the menu bar (or press Alt+N, and M in that order). In the Event dialog box • Click the <Manager> button. (or press Alt+G). In the dialog box for selecting the event type • Click the <Manager> button. (or press Alt+M). Explanation of each area The Event Manager consists of the following areas: (2) Event details display area (1) Event display area 190 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Event display area [When list is displayed] The event display area displays the icons (event icons) of the registered event, event link, break event conditions. An event icon consists of a mark indicating the type of event, and an event name. By selecting the right click menu -> [Detail], the details can be displayed (refer to "Event details display area"). The meaning of each mark is as follows: Table 7-19 Marks of Event Icon Mark Meaning E. Event condition L. Event link condition B. Break event condition The color of the character on the mark indicates the set status of the event. Table 7-20 Character Color Red Black Yellow Color of Character on Mark and its Meaning Mark Meaning E. L. Indicates that the event condition or event link condition which is used for various event conditions is enabled. B. Indicates that the various event conditions is enabled. The various events occurs when its condition is satisfied. E. L. Indicates that the event condition or event link condition which is used for various event conditions is disabled. B. Indicates that the various event conditions is disabled. The various events do not occur even when its condition is satisfied. E. L. Indicates that the symbol specified for an event is held pending because it cannot be recognized by the program currently loaded. B. Indicates that the various events is held pending. The various events do not occur even when its condition is satisfied. This area also has the following four functions: User’s Manual U16525EJ1V0UM 191 CHAPTER 7 WINDOW REFERENCE Jump function If the selected icon is that of an event condition, you can jump to the Source window, Assemble window, or Memory window, using an address condition as the jump pointer. You can jump easily by using the right click menu. The jump pointer will be as follows, depending on the set address condition. Table 7-21 Address Condition and Jump Pointer Setting of Address Condition Jump Pointer Setting as a point Specified address Setting as a range Lower address (Point address before the mask if a mask is specified) Setting as a bit Address at the bit position The jump destination window will be displayed from the jump pointer. Open function Opens the event setting dialog box corresponding to the selected event condition. Each setting dialog box displays the contents of the selected event condition. Operation • Double-click the icon, or click the <Open> button with selecting the icon. Enable status selection function The event corresponding to the selected icon can be enabled or disabled. The break events (but not the event and event link conditions) can be manipulated via their icons. Operation 1 Click on the mark of the icon using the left mouse button. 2 Select the icon, click the <Enable> or <Disable> button. If the event is enabled, it is disabled (black); if the event is disabled, it is enabled (red). The < Enable> button is displayed if the icon of an event that is disabled is selected; the <Disable> button is displayed if the icon of an event that is enabled is selected. Deletion function The registered event and set contents of the selected icon can be deleted. Operation 1 Select an icon. Two or more icons can be selected by using Shift and Ctrl keys. To select all the icons, select [View] -> [Select All] from the menu bar. 2 Click the <Delete> button or press the Delete key. Caution An event condition or event link condition can be deleted only when it is not being used for another event condition. If it is being used for another event, delete the event that is using the event condition or event link condition, and then delete the event condition or event link condition. 192 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (2) Event details display area [In detailed display mode] This area displays the detailed information corresponding to each event icon. This area is displayed only in the detailed display mode. Contents are displayed by using the following key information as a separator. Table 7-22 Separator for Displaying Event Details Key Information Contents Event condition [S] Status condition [Z] Access size condition [A] Address condition Symbol or expression: (actual address) [D] Data condition Symbol or expression: (actual address) [M] Mask condition Event link condition [P1] - [P4] Event link condition on "n"th line [D] Disable condition [P] Pass count condition Break condition [B] Break condition Functions often used (right-click menu) In this window, functions that are often used can be selected from the menu that is displayed by clicking the right mouse button. In this way, the same function can be used more easily than with the normal procedure. Sort By Name Displays icons in the order of event names. Sort By Kind Displays icons in the order of event types. Unsort Does not sort icons (default). Detail Displays the details. User’s Manual U16525EJ1V0UM 193 CHAPTER 7 WINDOW REFERENCE Overview Displays a list (default). Source Text Displays the corresponding source text and source line, using the position of the selected event as the jump destination address. If no line information exists at the jump destination address, however, you cannot jump. Opens the Source window. If an active Source windowis open, that window is displayed in the forefront (so that it can be manipulated). Assemble Displays the Assemble window from the position of the selected event, which is used as the jump destination address. Opens the Assemble window. If an active Assemble windowis open, that window is displayed in the forefront (so that it can be manipulated). Memory Displays the memory contents from the position of the selected event, which is used as the jump destination address. Opens the Memory window. If an active Memory windowis open, that window is displayed in the forefront (so that it can be manipulated). Function buttons 194 New... Opens the dialog box to create new event condition. By clicking each button of <Event...>,<Event.Link..>,<Break...>, the corresponding event setting dialog box can be opened with the new event name set.After the event setting dialog box has been opened, this dialog box is closed. <Manager...> Opens the Event Manager. <Cancel> Closes the dialog box to create new event condition. Open Opens the various event setting dialog box corresponding to the selected event condition. Each setting dialog box displays the contents of the selected event condition. This button is invalid if no event condition is selected or if two or more event conditions are selected. The Enter key performs the same operation. Enable/ Disable Enables or disables the selected various event condition (except event conditions and event link conditions). This button is invalid if an enabled/disabled event condition is not selected. Delete Deletes the selected event condition. When an event condition or an event link condition is to be deleted, an error occurs and the event condition or event link condition cannot be deleted if the event is used as a various event condition. This button is invalid if no event condition is selected. Delete All Deletes all event conditions except software break events Info... Opens the Select Display Information dialog box. This dialog box is used to change the display mode and rearrange event names. <Sort by Name> Sorts events into name order. <Sort by Kind> Sorts events into type order. <Unsort> Displays events in the order in which they have been registered without sorting the events. <Detail> Sets the detailed display mode. <Overview> Sets the list display mode. <Cancel> Closes this dialog box (same as ESC key). Close Closes this window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Related operations To save/restore event information Use this window as the current window, and open the View File Save dialog box by selecting [File] -> [Save As...] from the menu bar. To restore the set status of an event, open the View File Load dialog box by clicking the Open button. By loading an event setting file (*.evn), the previously set event information can be restored. To enable/disable an event An event can be enabled or disabled by clicking the mark of the event icon to be changed. By clicking Enable (red), the event can be disabled (black): by clicking Disable (black), the event can be enabled (red). This change can be also performed on the Event Manager or in each event setting dialog box. To change the display sequence of event icons Select the right-click menu -> [Sort By Name/Sort By Kind/Unsort] on the Event Manager. To display details of event condition Select the right-click menu -> [Detail] on the Event Manager. By selecting [Overview], the list can be displayed again. To delete an event Select the icon of the event to be deleted, and click the <Delete> button. Caution An event condition or event link condition cannot be deleted if it is being used for an event. Delete the event first, and then delete the event condition or event link condition. To manage a software break event Use the Software Break Manager, which is opened by selecting [Event] -> [Software Break Manager] from the menu bar. To create an event condition Create an event condition in the Event dialog box, which can be opened by clicking the Evn button. In addition, an event condition that is created when a hardware break is set in the source can also be used (refer to "Breakpoint setting/deletion function"). To create an event link condition Create an event link condition in the Event Link dialog box, which can be opened by selecting [Event] > [Event Link] from the menu bar. To set an event condition and event link condition as various event condition Set an event condition or event link condition as a various event condition in the Break dialog box which can be opened by clicking the corresponding button, such as <Break...> in the Event dialog box or Event Link dialog box. By dragging and dropping the event condition to be set from the Event Manager area at the lower part of the screen to the condition setting area on each event setting dialog box, the event condition can be easily set. Each event setting dialog box can also be opened by selecting from the [Event] menu. User’s Manual U16525EJ1V0UM 195 CHAPTER 7 WINDOW REFERENCE Software Break Manager This window is used to display, enable or disable, and delete software breaks. Up to 2000 software break events can be enabled at the same time (refer to "Software break"). Software breakpoints cannot be set in this window; they can be set in the Source window or Assemble window. Figure 7-46 Software Break Manager The section explains the following items: • Opening • Explanation of each area • Function buttons Opening This window can be opened as follows: • Select [Event] -> [Software Break Manager] from the menu bar (or press Alt+N, and M in that order). Explanation of each area The Software Break Manager consists of the following areas: (2) Brk (break mark display area) (3) File#Line / Symbol+Offset (breakpoint display area) (4) Address (address display area) (1) Name (event name display area) 196 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (1) Name (event name display area) This area displays the names of registered events, and the check boxes that indicate whether each event is enabled or disabled. An event name is displayed in the form of Swb+[number] in the default condition. It can be changed to an alphanumeric string of up to 256 characters. To change an event name, select and click a name. Then directly edit the name. To set the editing, press the Enter key. When an event is enabled, the check box is checked. Furthermore, the name jumps to the Source window by double-clicking an event name if the event name corresponds to the source line, whereas the name jumps to the Assemble window if it does not correspond to the source line. Reference By clicking Name (on the label), the character strings of the displayed items can be compared and sorted lexicographically (in alphabetical order). Whether the character strings are compared or sorted in ascending or descending order can be alternately selected by clicking the mouse. (2) Brk (break mark display area) The '>' mark is displayed for a software break event that is set at the current PC position (so that the software break event that caused a break can be easily identified). (3) File#Line / Symbol+Offset (breakpoint display area) This area displays the location at which a software break event was set as follows: If the event corresponds to the source line. Program$file name#line number If the event dose not correspond to the source line. Program$file name#symbol+offset Events are evaluated based on this when a symbol is re-downloaded. User’s Manual U16525EJ1V0UM 197 CHAPTER 7 WINDOW REFERENCE Reference By clicking File#Line/Symbol+Offset (on the label), the character strings of the displayed items can be compared and sorted lexicographically (in alphabetical order). Whether the character strings are compared or sorted in ascending or descending order can be alternately selected by clicking the mouse. (4) Address (address display area) This area displays the address at which a software break event is set. Reference By clicking Address (on the label), the numeric values of the displayed items can be compared and sorted. Whether the values are compared or sorted in ascending or descending order can be alternately selected by clicking the mouse. Function buttons 198 Enable Enables the selected event. Disable Disables the selected event. Delete Deletes the selected event. Delete ALL Deletes all the set software break events. Close Closes this window. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Event dialog box This window is used to register and display event conditions. An event condition registered in this dialog box will be automatically registered to Event Manager. As an event condition, one event can be set for two or more event conditions (break and event link). Up to 256 event conditions can be registered. However, the number of event conditions that can be simultaneously used is limited (refer to "Table 7-18 Maximum Number of Valid Events for Each Event Condition"). Figure 7-47 Event Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons User’s Manual U16525EJ1V0UM 199 CHAPTER 7 WINDOW REFERENCE Opening This dialog box can be opened as follows: In normal mode If the Event dialog box is opened as follows, an event condition can be registered without its purpose being specified. • Click the Evn button. • Select [Event] -> [Event...] from the menu bar (or press Alt+N, and E in that order). In select mode If the <OK> button is pressed when the Event dialog box has been opened as follows, an event condition can be registered in the setting dialog box from which this dialog box was opened. • In each various event setting dialog box Click the <Add Event...> button. (or press Alt+E). In the select mode, the setting dialog box from which the Event Link dialog box was opened is displayed on the title bar. Explanation of each area The Event dialog box consists of the following areas: (2) Event Status (status selection area) (3) Access Size (access size selection area) (4) Address (address setting area) (5) Data, Mask (data setting area) (6) Event Manager (event manager area) (1) Event Name (event name setting area) (1) Event Name (event name setting area) This area is used to set a event name. Directly input an alphanumeric string of up to eight characters as a name. To display the contents of an already created event condition, select from the drop-down list. In the select mode, the selected event condition can be set in the event condition setting area of the setting dialog box that called the Event dialog box. The mark on the left of this area indicates the utilization status of events (refer to "Table 7-20 Color of Character on Mark and its Meaning"). The gray E. mark indicates that the event condition is being edited and has not been registered yet. 200 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (2) Event Status (status selection area) This area is used to select a status condition. By specifying a status condition, the type of the execution event and an access event is determined (if an execution event is specified, nothing can be input to the Access Size, Data Mask, and Data areas). The status conditions that can be specified are listed below. A status condition can also be specified in abbreviated form. Uppercase and lowercase characters are not distinguished in the input status condition. Table 7-23 List of Status Conditions <Execution event> Status a. Abbreviation Meaning Execution EX Program execution Before Execution EX-B Program execution (break before execution) a Two or more break events can be specified. but up to two enable break events including access events. <Access event> Status (3) Abbreviation Meaning R/W RW Data read/write Read R Data read Write W Data write Access Size (access size selection area) This area is used to set and select an access size condition. By specifying an access size condition, the access width of a data condition to be detected by an access event is determined. The access size conditions that can be specified are listed below. An access size condition can also be specified in abbreviated form. Uppercase and lowercase characters are not distinguished in the input access size condition. Table 7-24 Size List of Access Size Conditions (Event) Abbreviation Meaning Byte B Detects data condition with 8-bit width (only during 8-bit access). Half Word HW Detects data condition with 16-bit width (only during 16-bit access). Word W Detects data condition with 32-bit width (only during 32-bit access). User’s Manual U16525EJ1V0UM 201 CHAPTER 7 WINDOW REFERENCE Table 7-24 Size List of Access Size Conditions (Event) Abbreviation Meaning No Condition NC Does not detect access size (nothing can be input to the Data area). Bit 1 Detects data condition with 1-bit width (only during 8-bit access). In this case, a data condition is detected with 1-bit width. Because of the operation of the in-circuit emulator, access to a bit is not directly detected; the ID850NWC detects a dummy bit access by internally setting address conditions and data conditions as follows: Input example: Address: FE20.1 Data: 1 | Setting to in-circuit emulator: Address: FE20 Data: 00000010B Mask: 11111101B If another bit of the same address is accessed or if all the 8 bits of the same address are accessed, therefore, an event is detected in accordance with the specified status if the address and bit match the specified value of [address.bit]. When data is written to a bit, all the 8 bits are read/written. If read or read/write is specified as the status, an event occurs if a read operation is performed at this time if the value of the specified [Address.bit] matches. If no access size is specified, judgment is automatically made from the address condition and data condition, and the following is set: • Bit if the address condition is set in bit units • Byte if the address condition is set in 8-bit units • Half Word if the address condition is set in 16-bit units • Word if the address condition is set in 32-bit units • No Condition if no data condition is specified (4) Address (address setting area) An address can be also specified by a symbol or expression (refer to "Table 7-10 Symbols"). The default radix for inputting a numeric value is hexadecimal. Settable range 0 =< address value =< 0xFFFFFFFF Address Set an address condition (lower address - higher address). 202 User’s Manual U16525EJ1V0UM Specifying CHAPTER 7 WINDOW REFERENCE Caution Specify a 28-bit address, since physical address and image space are distinguished in setting event. The following can be set: (5) Setting as a point Set a value to only the lower address, or set the same value to the lower address and the higher address. Setting as a range Set a value to the lower address and the higher address. Setting as a bit Set a value to only the lower address, or set the same value to the lower address and the higher address. Specify a value in the form of address.bit. The value of bit, which indicates the bit position, must be 0 =<bit =<7. Data, Mask (data setting area) Data, which sets an data value, and Mask, which sets the mask value of an data value, are set as data conditions. The default radix for inputting a numeric value is hexadecimal. Both the data and mask may be omitted. The settable range differs as follows depending on the access size condition specified in the Access Size area. Table 7-25 Settable Range of Data Condition Access Size Settable range Byte 0 =< data value =< 0xFF 0 =< mask value =< 0xFF Half Word 0 =< data value =< 0xFFFF 0 =< mask value =< 0xFFFF Word 0 =< data value =< 0xFFFFFFFF 0 =< mask value =< 0xFFFFFFFF Bit Data value = 0 or 1 Mask value = Cannot be specified. Data Set a data value. Specify a value within the settable range. A symbol or expression can be also specified by a symbol or expression ( refer to "Table 7-10 Specifying Symbols"). Mask Set a mask value for the data value. When a mask is set, the data value for the bit whose mask value is 1 may be 0 or 1. The data value for a bit whose mask value is 1 may be 0 or 1. Example 1: Data 0x4000 User’s Manual U16525EJ1V0UM 203 CHAPTER 7 WINDOW REFERENCE Mask 0xFF With this setting, addresses 0x4000 to 0x40FF satisfy the condition. Example 2: Data 0x4000 Mask 0x101 With this setting, addresses 0x4000, 0x4001, 0x4100, and 0x4101 satisfy the condition. (6) Event Manager (event manager area) This area displays a list of various event conditions registered. In this area, the following operations can be performed. Displaying set contents Select an event and click the <Open> button or double-click the event. The setting dialog box corresponding to the selected event will be opened and the set contents of the event will be displayed. Delete A selected event can be deleted by selecting the icon of the event and clicking the <Delete> button or pressing the Delete key while focusing on the event manager area. Changing display mode and sorting The display mode of and sorting in the event manager area can be selected by clicking the <Info...> button. Function buttons Related setting event 204 OK Automatically registers the event condition being edited, if any, and closes this dialog box. In the select mode An event condition is selected and the setting dialog box (indicated on the title bar) that called the Event Link dialog box is displayed again. If the calling dialog box has already been closed, the select mode is returned to the normal mode, and the Event dialog box is not closed. Otherwise, this dialog box will be closed. New Newly creates an event condition in this dialog box. An event condition name is automatically created and a new event condition is prepared. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Set (when a new event link is created or an event link is changed) Registers the various event condition. Because the dialog box is not closed even after an event has been registered, new event conditions can be registered. In the select mode An event condition is selected. If there is an event being edited, it is automatically registered and selected. Clear (when an event is not edited) Clears the contents of the event condition. This button is displayed when an event condition has not been edited. This button and the <Restore> button are alternately displayed. Restore (when an event is edited) Restores the contents of an edited event condition. If an event condition not registered is displayed, all the fields other than the event name field are blank or the default values are set. This button and the <Clear> button are alternately displayed. Cancel Close Closes this dialog box. Even if an event condition is being edited, it is not registered and the dialog box is closed. <Cancel> is displayed if a condition is not created, changed, or deleted; <Close> is displayed if it is. Help Opens the Help window. Related dialog box Event Link... Opens the Event Link dialog box. Break... Opens the Break dialog box. Trace... Cannot be selected. Manager Opens the Event Manager. Open (When only one event is selected) Opens the various event setting dialog box corresponding to the selected event condition. Each setting dialog box displays the contents of the selected event condition. The Enter key performs the same operation. Remove (When event is selected) Deletes the selected event condition. When an event condition or an event link condition is to be deleted, an error occurs and the event condition or event link condition cannot be deleted if the event is used as a various event condition. Other Shrink <<< (When area is displayed) Turns off display of the event manager area. At this time, the size of the dialog box is reduced. Expand >>> (When area is not displayed) Displays the event manager area. At this time, the size of the dialog box is expanded. Info... Opens the Select Display Information dialog box. This dialog box is used to change the display mode and rearrange event names. <Sort by Name> Sorts events into name order. <Sort by Kind> Sorts events into type order. <Unsort> Displays events in the order in which they have been registered without sorting the events. <Detail> Sets the detailed display mode. <Overview> Sets the list display mode. <Cancel> Closes this dialog box (same as ESC key). User’s Manual U16525EJ1V0UM 205 CHAPTER 7 WINDOW REFERENCE Event Link dialog box This window is used to register and display event link conditions. A event link condition registered in this dialog box will be automatically registered to the Event Manager. An event link condition is an event condition that is generated only if the user program is executed in the sequence specified by a set event condition. Up to four sequences can be specified. If a disable condition is detected while the program is being executed, however, the event conditions that have so far been satisfied are initialized, and the event conditions are detected again starting from the first event condition. If a link condition and a disable condition are detected at the same time, the disable condition takes precedence. As an event condition, one event can be set for two or more event conditions. Up to 256 event link conditions can be registered. However, the number of event link conditions that can be simultaneously used (valid) is limited (refer to "Table 7-18 Maximum Number of Valid Events for Each Event Condition"). Figure 7-48 206 Event Link Dialog Box User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE The section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: In normal mode If the Event Link dialog box is opened as follows, an event link condition can be registered without its purpose being specified. • Select [Event] -> [Event Link...] from the menu bar (or press Alt+N, and L in that order). In select mode If the <OK> button is pressed when the Event Link dialog box has been opened as follows, an event link condition can be registered in the setting dialog box from which this dialog box was opened. • In each various event setting dialog box Click the <Add Link...> button. (or press Alt+L). In the select mode, the setting dialog box from which the Event Link dialog box was opened is displayed on the title bar. Explanation of each area The Event Link dialog box consists of the following areas: (2) Phase1, Phase2, Phase3, Phase4 (link condition setting area) (3) Disable (disable condition setting area) (4) Pass Count (pass count setting area) (5) Event Manager (event manager area) (1) Link Name (event link name setting area) (1) Link Name (event link name setting area) This area is used to set a event link name. Directly input an alphanumeric string of up to eight characters as a name. To display the contents of an already created event link condition, select from the drop-down list. In the select mode, the selected event condition can be set in the event kink condition setting area of the setting dialog box that called the Event Link dialog box. The mark on the left of this area indicates the utilization status of event link condition (refer to "Table 7- User’s Manual U16525EJ1V0UM 207 CHAPTER 7 WINDOW REFERENCE 20 Color of Character on Mark and its Meaning"). The mark "L" in gray indicates that an event link condition is being edited and has not been registered yet. (2) Phase1, Phase2, Phase3, Phase4 (link condition setting area) This area is used to specify the sequence in which event conditions and events are detected. Set Phase 1 -> Phase 2 -> Phase 3 -> Phase 4, in that order. Phase 4 does not have to be set. In this case, an event occurs when the event condition set for the last phase has been detected. An event condition can be set for only Phase 1 or the same event condition can be set for two or more Phases. The number of event conditions that can be set to each phase of this area and whole the dialog box, is as follows: Table 7-26 The Number of Event Conditions in Event Link Dialog Box Connected IE IE-V850E1-CD-NW Each phase Tatal(Each phase area and Disable area) (execution/access) Nx85ET(RCU0+TEU+ TRCU) 10a 12(max) Nx85E901(RCU0), RCU1 1b 2C a. Can be set in Phase1-4 (expect the events before execution) b. Can be set only in Phase 1 and Phase 2 (must always be set in two stages) c. Only events before execution Setting event condition in each area Select an event condition in the Event Manager area, and click the <Add> button or drag and drop an event condition. An event link condition can also be set by dragging and dropping not only in this dialog box, but also in the Event Manager area of each various event setting dialog box or the Event Manager. In addition, the Event dialog box can be opened in "select mode" by clicking the <Add Event...> button, and the event condition to be set can be selected. In the event condition setting area in this dialog box, an event condition can be alternately copied or moved by dragging and dropping. • If an event condition is dropped only by the mouse, it is moved. • If an event condition is dropped with the Shift key held down, it is moved. • If an event condition is dropped with the Ctrl key held down, it is copied. 208 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE (3) Disable (disable condition setting area) This area is used to set an event condition that invalidates the event conditions that have so far been satisfied (refer to "Setting event condition in each area"). The number of event conditions that can be set in this area is up to 2 in case of Nx85ET(RCU0+TEU+TRCU). In case of Nx85E901(RCU0), RCU1, this area does not have to be set. (4) Pass Count (pass count setting area) This area is used to set a pass count condition (settable range: 1 to 4095) . A pass count condition specifies how many times an event condition must be satisfied during user program execution before a given condition is satisfied. If the pass count is set to 1, the condition is satisfied as soon as the event condition is satisfied. If no pass count is specified, 1 is assumed. In case of Nx85E901(RCU0), RCU1, this area does not have to be set. (5) Event Manager (event manager area) This area displays a list of various event conditions registered. For details, refer to "Event Manager (event manager area)". User’s Manual U16525EJ1V0UM 209 CHAPTER 7 WINDOW REFERENCE Function buttons Related setting event OK Automatically registers the event condition being edited, if any, and closes this dialog box. In the select mode An event condition is selected and the setting dialog box (indicated on the title bar) that called the Event Link dialog box is displayed again. If the calling dialog box has already been closed, the select mode is returned to the normal mode, and the Event dialog box is not closed. Otherwise, this dialog box will be closed. New Newly creates an event condition in this dialog box. An event condition name is automatically created and a new event condition is prepared. Set (when a new event link is created or an event link is changed) Registers the various event condition. Because the dialog box is not closed even after an event has been registered, new event conditions can be registered. In the select mode An event condition is selected. If there is an event being edited, it is automatically registered and selected. Clear (when an event is not edited) Clears the contents of the event condition. This button is displayed when an event condition has not been edited. This button and the <Restore> button are alternately displayed. Restore (when an event is edited) Restores the contents of an edited event condition. If an event condition not registered is displayed, all the fields other than the event name field are blank or the default values are set. This button and the <Clear> button are alternately displayed. Cancel Close Closes this dialog box. Even if an event condition is being edited, it is not registered and the dialog box is closed. <Cancel> is displayed if a condition is not created, changed, or deleted; <Close> is displayed if it is. Help Opens the Help window. Related dialog box 210 Add Event... Opens the Event dialog box in the select mode, and selects or newly creates an event condition to be set. The event condition will be added to the area selected when the < Add Event...> button is pressed. Open (When only one event is selected) Opens the various event setting dialog box corresponding to the selected event condition. Each setting dialog box displays the contents of the selected event condition. The Enter key performs the same operation. Remove (When event is selected) Deletes the selected event condition. When an event condition or an event link condition is to be deleted, an error occurs and the event condition or event link condition cannot be deleted if the event is used as a various event condition. Add The event condition and event link condition selected in Event Manager area add to setting area with a focus. The event condition will be added to the area selected when this button is pressed. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Other... Opens the dialog box for selecting the event type. By clicking each button of <Event...>,<Event.Link...>,<Break...>, the corresponding event setting dialog box can be opened with the new event name set.After the event setting dialog box has been opened, this dialog box is closed. <Manager...> Opens the Event Manager. <Cancel> Closes the dialog box to create new event condition. Other Shrink <<< (When area is displayed) Turns off display of the event manager area. At this time, the size of the dialog box is reduced. Expand >>> (When area is not displayed) Displays the event manager area. At this time, the size of the dialog box is expanded. Info... Opens the Select Display Information dialog box. This dialog box is used to change the display mode and rearrange event names. <Sort by Name> Sorts events into name order. <Sort by Kind> Sorts events into type order. <Unsort> Displays events in the order in which they have been registered without sorting the events. <Detail> Sets the detailed display mode. <Overview> Sets the list display mode. <Cancel> Closes this dialog box (same as ESC key). User’s Manual U16525EJ1V0UM 211 CHAPTER 7 WINDOW REFERENCE Break dialog box This dialog box is used to register; set, and display break event conditions. A break event condition registered in this dialog box will be automatically registered to Event Manager. A break event condition automatically becomes valid when it has been registered. Up to 256 break event conditions can be registered. However, the number of break event conditions that can be simultaneously used is limited (refer to "Table 7-18 Maximum Number of Valid Events for Each Event Condition). If the maximum number of break event conditions that can be used at the same time is exceeded or if the number of event conditions or event link conditions used exceeds the maximum limit, therefore, register a break event condition in the disabled state. If [Run] -> [Ignore Break Point] is selected from the menu bar, a break event condition does not operate even if it is valid. Figure 7-49 Break Dialog Box The section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Click the Brk button. • Select [Event] -> [Break...] from the menu bar (or press Alt+N, and B in that order). 212 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Explanation of each area The Break dialog box consists of the following areas: (2) Break Event (break condition setting area) (3) Event Manager (event manager area) (1) Break Name (break event name setting area) (1) Break Name (break event name setting area) This area is used to set a break event name. Directly input an alphanumeric string of up to eight characters as a name. To display the contents of an already created event condition, select from the drop-down list. The mark on the left of this area indicates the utilization status of events (refer to "Table 7-20 Color of Character on Mark and its Meaning"). The gray mark indicates that an event condition is being edited and has not been registered yet. By clicking the left mark, an event condition can be validated or invalidated. (2) Break Event (break condition setting area) This area is used to set an event condition for break. The number of event conditions that can be set in this area, combining execution events and access events, is as follows: Table 7-27 Number of Events Settable in Break Condition Setting Area Total (execution/access) Connected IE IE-V850E1-CD-NW Nx85ET(RCU0+TEU+ TRCU) 14(10a/4b) Nx85E901(RCU0), RCU1 2 a. Two events before execution and eight events after execution(max) b. four(max) The number of event link conditions explained in Table 7-18 Maximum Number of Valid Events for Each Event Condition can be used as long as the number of event conditions does not exceed the maximum number of event conditions simultaneously usable. User’s Manual U16525EJ1V0UM 213 CHAPTER 7 WINDOW REFERENCE Setting event condition and event link condition in each area Select an event condition or event link condition in the Event Manager area, and click the <Add> button or drag and drop an event condition or event link condition. An event link condition can also be set by dragging and dropping not only in this dialog box, but also in the Event Manager area of each various event setting dialog box or the Event Manager. In addition, Event dialog box or Event Link dialog box can be opened in "select mode" by clicking the <Add Event...> or <Add Link...> button, and the event condition or event link condition to be set can be selected. In the event condition setting area in this dialog box, an event condition can be alternately copied or moved by dragging and dropping. • If an event condition is dropped only by the mouse, it is moved. • If an event condition is dropped with the Shift key held down, it is moved. • If an event condition is dropped with the Ctrl key held down, it is copied. (3) Event Manager (event manager area) This area displays a list of various event conditions registered. For details, refer to "Event Manager (event manager area)". Function buttons Related setting event 214 OK Automatically registers the event condition being edited, if any, and closes this dialog box. The event condition becomes valid as soon as it has been registered. New Newly creates an event condition in this dialog box. An event condition name is automatically created and a new event condition is prepared. Set (when a new event link is created or an event link is changed) Registers the various event condition. Because the dialog box is not closed even after an event has been registered, new event conditions can be registered. Each event condition becomes valid as soon as it has been registered. If an already registered event condition is displayed, the <Enable> or <Disable> button is alternately displayed. Enable/Disable (when a registered event is displayed) Validates (enables) or invalidates (disables) the selected event condition. However, event conditions and event link conditions cannot be enabled or disabled. This button and the <Set> button are alternately displayed. Clear (when an event is not edited) Clears the contents of the event condition. This button is displayed when an event condition has not been edited. This button and the <Restore> button are alternately displayed. Restore (when an event is edited) Restores the contents of an edited event condition. If an event condition not registered is displayed, all the fields other than the event name field are blank or the default values are set. This button and the <Clear> button are alternately displayed. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Cancel Close Closes this dialog box. Even if an event condition is being edited, it is not registered and the dialog box is closed. <Cancel> is displayed if a condition is not created, changed, or deleted; <Close> is displayed if it is. Help Opens the Help window. Related dialog box Add Event... Opens the Event dialog box in the select mode, and selects or newly creates an event condition to be set. The event condition will be added to the area selected when the < Add Event...> button is pressed. Add Link... Opens the Event Link dialog box in the select mode, and selects or newly creates an event link condition. The event condition will be added to the area selected when the < Add Link...> button is pressed. Open (When only one event is selected) Opens the various event setting dialog box corresponding to the selected event condition. Each setting dialog box displays the contents of the selected event condition. The Enter key performs the same operation. Remove (When event is selected) Deletes the selected event condition. When an event condition or an event link condition is to be deleted, an error occurs and the event condition or event link condition cannot be deleted if the event is used as a various event condition. Add The event condition and event link condition selected in Event Manager area add to setting area with a focus. The event condition will be added to the area selected when this button is pressed. Other... Opens the dialog box for selecting the event type. By clicking each button of <Event...>,<Event.Link...>,<Break...>, the corresponding event setting dialog box can be opened with the new event name set.After the event setting dialog box has been opened, this dialog box is closed. <Manager...> Opens the Event Manager. <Cancel> Closes the dialog box to create event condition. Other Shrink <<< (When area is displayed) Turns off display of the event manager area. At this time, the size of the dialog box is reduced. Expand >>> (When area is not displayed) Displays the event manager area. At this time, the size of the dialog box is expanded. Info... Opens the Select Display Information dialog box. This dialog box is used to change the display mode and rearrange event names. <Sort by Name> Sorts events into name order. <Sort by Kind> Sorts events into type order. <Unsort> Displays events in the order in which they have been registered without sorting the events. <Detail> Sets the detailed display mode. <Overview> Sets the list display mode. <Cancel> Closes this dialog box (same as ESC key). User’s Manual U16525EJ1V0UM 215 CHAPTER 7 WINDOW REFERENCE Reset Debugger dialog box This dialog box is used to initialize the ID850NWC, CPU, and symbol information. Specify what is to be initialized by using the check box. In the default condition, the ID850NWC is initialized. Figure 7-50 Reset Debugger Dialog Box This section explains the following items: • Opening • Explanation of each area • Function buttons Opening This dialog box can be opened as follows: • Select [File] -> [Debugger Reset...] on the menu bar (or press Alt+F, and R in that order). Explanation of each area The Reset Debugger dialog box consists of the following areas: (1) Reset subject selection area (1) Reset subject selection area This area is used to select what is to be initialized. 216 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Debugger Initializes the ID850NWC (default). Symbol Initializes the symbol information. Target CPU Initializes the CPU. Function buttons OK Initializes the ID850NWC, symbol information, or CPU. Cancel Ignores the setting and closes this dialog box. Help Opens the Help window. User’s Manual U16525EJ1V0UM 217 CHAPTER 7 WINDOW REFERENCE Exit Debugger dialog box This dialog box is used to select whether the current debug environment is saved to a project file or not before terminating the ID850NWC. It can be specified in the Debugger Option dialog box that the ID850NWC is terminated without this confirmation dialog box being opened. Figure 7-51 Exit Debugger Dialog Box Reference If an attempt is made to terminate the ID850NWC while the user program is being executed, the following message is displayed and the program execution can be stopped. <Yes> button is selected Execution of the user program is stopped and then the Exit Debugger dialog box is displayed. If it is specified in the Debugger Option dialog box that the Exit Debugger dialog box is not to be displayed, however, the ID850NWC is terminated. <No> button is selected Execution of the user program is not stopped and the Exit Debugger dialog box is not displayed. The ID850NWC is not terminated. This section explains the following items: • Opening • Function buttons 218 User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Opening This dialog box can be opened as follows: • Select [File] -> [Exit] from the menu bar (or press Alt+F, and X in that order). • Press the Alt+F4 keys simultaneously. • If forcible termination, such as to terminate the application, has been executed on the task list that terminates Windows. Function buttons Yes Saves the current debug environment to a project file, closes all the windows, and terminates the ID850NWC. If a project file name is not specified, the Project File Save dialog box is opened. If the < Cancel> button is selected on the Project File Save dialog box, the environment is neither saved to a project file nor is the ID850NWC terminated. If a project file is loaded or saved during debugger operation, this button has the default focus. No Closes all the windows and terminates the ID850NWC. If a project file is not loaded or saved during debugger operation, this button has the default focus. Cancel Closes this dialog box without executing anything. User’s Manual U16525EJ1V0UM 219 CHAPTER 7 WINDOW REFERENCE About dialog box This dialog box displays the version information of the ID850NWC and in-circuit emulator (the year is displayed in 4 digits). The following version information is displayed: • Product version of ID850NWC • Version of device file • Version of GUI • Version of debugger DLL • Version of assembler DLL • Version of executor Figure 7-52 About Dialog Box This section explains the following items: • Opening • Function buttons Opening This dialog box can be opened as follows: • Select [Help]->[About] (or press Alt+H, and A in that order). Function buttons OK 220 Closes this dialog box. User’s Manual U16525EJ1V0UM CHAPTER 7 WINDOW REFERENCE Console window This window is used to input commands that control the ID850NWC. Because the key bind is Emacs-like, the accelerator key is not acknowledged if the Console window is active. However, the F1 key displays the help of the Console window. While the Console window is open, an error message window with only an <OK> button is displayed in the Console window. Refer to "COMMAND REFERENCE" for details on the command specifications. Figure 7-53 Console Window This section explains the following items: • Opening Opening This window can be opened as follows: • Select [Browse] -> [Console] from the menu bar (or press Alt+B, and N in that order). User’s Manual U16525EJ1V0UM 221 CHAPTER 8 COMMAND REFERENCE CHAPTER 8 COMMAND REFERENCE This section explains the command functions of the ID850NWC in detail. 8.1 Command Line Rules The specification of command lines has the following rules: • Command name, option, and argument are specified for command line. • To divide words, a space (space key or tab key) is used. • At the end of a line, a line feed character or a semicolon is used. • When a command name and an option are entered to the point of identifiability, they are recognized. • In script, command names have to be entered completely. Command format command -options arg1 arg2 arg3 ... 8.2 Command List The list of ID850NWC commands is shown in Table 8-1 and Table 8-2 . Table 8-1 List of Debugger Control Commands Command Name 222 Function address Evaluation of address expression Converts the address expression specified with expression into address. assemble Disassemble/line assemble (a) Assembles the character strings specified with code from the address specified with address. batch Executing batch (with echo) Executes in batch displaying files specified with script name on the screen. breakpoint Setting/deletion of breakpoint (b) Operates breakpoint specified with options and address. cache Setting of cache Sets I cache and D cache. dbgexit Terminating ID850NWC Terminates the ID850NWC. download Download of files (l) Downloads files specified with filename according to options. extwin Creation of expansion window Creates expansion window with script file. finish Returning from function Executes until it returns to the program that called the current function. go Continuous execution (g) Executes program continuously. User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE Table 8-1 List of Debugger Control Commands Command Name Function help Display of help Displays help of Dcl. hook Setting of hook Sets the procedure for hook with script file. ie Display/setting of IE register This command depends on the IE. jump Jump to window (j) Displays the window specified with options. map Setting/deletion of memory mapping Sets, deletes, and displays memory mapping. mdi Setting of expansion window Sets the size and title name of the expansion window. memory Display/setting of memory (m) Sets value in the memory of the address specified with address according to options. module Display of the list of files and functions Displays the list of files and functions of the load module specified with progname. next Procedure step (n) Executes the procedure steps. refresh Redrawing of window Redraws the window and updates the data. register Display/setting of register value and I/O register value Sets value in the register specified with regname. reset Reset Resets CPU, ID850NWC or symbols. run Reset and execution of CPU (r) Resets program and executes it. step Step execution (s) Executes step execution. stop Stop execution Stops the program forcibly. upload Upload Saves the memory data or coverage data within the specified range in a file. version Display of the version information Displays the version information of the debugger. watch Display/setting of variables (w) Displays and sets the variables. where Trace of stack Executes the back-trace of the stack. wish Start of Tclet Starts the script using Tk (Tclet). User’s Manual U16525EJ1V0UM 223 CHAPTER 8 COMMAND REFERENCE Table 8-2 List of Console/Tcl Commands Command Name 8.3 Function alias Creation of another name cd Change of directory clear Clears the screen echo Echo exit Close/end history Display of history ls Display of files pwd Check of the directory source Execution of batch time Measurement of time for commands tkcon Console control unalias Deletion of another name which Display of the command path or another name Other commands Based on Tcl/Tk 8.1 List of Variables • dcl(chip) - Chip name read only • dcl(prjfile) - Project file name read only • dcl(srcpath) - Source path read only • dcl(ieid) - IE type read only • dcl(iestat) - IE status read only • dcl(bkstat) - Break status read only • env(LANG) - Language • dcl_version - Dcl version read only 8.4 List of Packages • tcltest - Restoration test • cwind - Automatic window control • BWidget - Toolkit 8.5 Key Bind • tcsh + emacs like • Complement of command name [Tab] • Complement of file name [Tab] • HTML help [F1] 224 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE 8.6 Expansion window The expansion windows can be created using Tk. In the expansion windows, Widget is allocated with '.dcl' as a root instead of '.'. When the following script files are allocated in bin/idtcl/tools/, an expansion window is added on selecting [Browse] -> [Others] from the menu bar. The mdi command, an exclusive command for expansion windows, has been added. # Sample.tcl wm protocol .dcl WM_DELETE_WINDOW { exit } mdi geometry 100 50 button .dcl.b -text Push -command exit pack .dcl.b In expansion windows, Tk menu commands cannot be used because of the restrictions of MDI windows. 8.7 Callback Procedure Expansion windows can hold dcl_asyncproc procedures called by asynchronous messages. proc dcl_asyncproc {mid} { if {$mid == 19} { redraw } } The asynchronous message ID is passed for the argument of the dcl_asyncproc procedure. The message IDs are shown below: Table 8-3 Message ID Message ID Meaning 9 After changing configuration 10 After registering event 11 After deleting event 12 Before executing 13 After breaking 14 After resetting CPU 15 After resetting ID850NWC 17 After changing extended option 18 After changing debugger option 19 After downloading 20 After changing memory or register 45 After resetting symbol User’s Manual U16525EJ1V0UM 225 CHAPTER 8 COMMAND REFERENCE 8.8 Hook Procedure A hook can be set in the ID850NWC using the hook procedure. The hook procedures are shown below: BeforeDownload Hook before downloading AfterDownload Hook after downloading AfterCpuReset Hook after resetting CPU BeforeCpuRun Hook before starting execution AfterCpuStop Hook after breaking By using hook procedures, register values can be changed before downloading programs or after resetting the CPU. An actual example of the procedure is shown below. A hook is valid till the ID850NWC is closed. [When hook is set with ID850NWC control command] 1 Create script file a. with an editor. 2 Start up the ID850NWC, select [Browse] menu -> [Console], and open the Console window. 3 If the script file is executed in the window as below, the hook in the script file is set. %hook test.tcl [When hook is set on downloading of project file] 1 Create script file a. with an editor. Caution Be sure that the script file name is the same as the project file. Example: The script file corresponding to test.prj is test.tcl. Allocate test.prj, test.pri, and test.tcl in the same directory. 2 Start up the ID850NWC and read test.prj. The hook in the script file is set. An example of the contents of a script file is shown as below (using the ICE for the V850E/MS1). 226 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE proc BeforeDownload {} { register MM 0x7 register PMC8 0xff register PMC9 0xff register PMCX 0xe0 } proc AfterCpuReset {} { register MM 0x7 register PMC8 0xff register PMC9 0xff register PMCX 0xe0 } 8.9 Related Files • Executes when the aliases.tcl console is opened. Sets the default alias etc. • Executes when the project file name.tcl project is opened. The hook of BeforeDownload, AfterDownload, AfterCpuReset, BeforeCpuRun and AfterCpuStop can be used. • Executes when the load module name.tcl load module is downloaded. The hook of BeforeDownload, AfterDownload, AfterCpuReset, BeforeCpuRun and AfterCpuStop can be used. 8.10 Cautions • The separator for file and path is a slash (/). • When a console or an expansion window is active, the accelerator key cannot be acknowledged. • When a console is open, error messages are output to the console. • To terminate the command forcibly, close the console. • The execution of external commands (DOS commands) is OFF by default. 8.11 Commands In this section, each command is explained using the format shown below. User’s Manual U16525EJ1V0UM 227 CHAPTER 8 COMMAND REFERENCE Command name Gives a brief explanation of the function of the command. Name Describes the command name. Input format Describes the input format of the command. Functions Explains the functions of the command. Usage example Shows an example of the usage of the command. 228 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE address • Name • Input format • Functions • Usage example Name address - Evaluation of address expression Input format address expression Functions Converts the address expression specified by expression into address. Usage example (IDCON) 1 % address main 0xaa (IDCON) 2 % address main+1 0xab User’s Manual U16525EJ1V0UM 229 CHAPTER 8 COMMAND REFERENCE assemble • Name • Input format • Functions • Usage example Name assemble - Disassemble/line assemble Input format assemble ?options? address ?code? Functions Assembles the character strings specified by code from the address specified by address. When '.' is specified for address, it is understood as an address continuing from the immediately previous assemble. When code is omitted, it is assembled from the address specified by address. The followings are options. They are ignored for assembly. -code Command code is also displayed. It is ignored for assembly. -number number number line is displayed. It is ignored for assembly. Usage example (IDCON) 1 % assemble -n 5 main 0x000000aa B7 PUSH HL 0x000000ab B1 PUSH AX 0x000000ac 891C MOVW AX,SP 0x000000ae D6 MOVW HL,AX 0x000000af A100 MOV A,#0H (IDCON) 2 % assemble main mov a,b (IDCON) 3 % assemble . mov a,b 230 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE batch • Name • Input format • Functions • Usage example Name batch - Executing batch (with echo) Input format batch scriptname Functions Executes in batch with displaying files specified by scriptname on the screen. Nesting is possible. Usage example (IDCON) 1 % clear (IDCON) 2 % batch bat_file.tcl (IDCON) 3 % tkcon save a:/log.txt User’s Manual U16525EJ1V0UM 231 CHAPTER 8 COMMAND REFERENCE breakpoint • Name • Input format • Functions • Usage example Name breakpoint - Setting/deletion of breakpoint Input format breakpoint ?options? ?address1? ?address2? breakpoint -delete brkno breakpoint -enable brkno breakpoint -disable brkno breakpoint -information Functions Operates the breakpoint specified by options and address. If a breakpoint can be set correctly, the breakpoint number is returned. The following are options: 232 -software A software break is specified. -hardware A hardware break is specified (default). -execute The address execution break is set (default). -beforeexecute The break before address execution is set (default : RCU0, RCU1). -read An address data read break is set. -write An address data write break is set. -access An address data access break is set. -size size The access size is set (8, 16, or 32). -data value The data condition is set. -datamask value The data mask is set. -information The list of breakpoints is displayed. -delete The breakpoint whose number is specified is deleted. User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE -disable The breakpoint whose number is specified is disabled. -enable The breakpoint whose number is specified is enabled. Usage example (IDCON) 1 % breakpoint main 1 (IDCON) 2 % breakpoint -i 1 Brk00001 enable rammon.c#17 (IDCON) 3 % breakpoint -software sub 2 (IDCON) 4 % breakpoint -i 1 Brk00001 enable rammon.c#17 2 Brk00001 enable rammon.c#8 (IDCON) 5 % breakpoint -disable 2 (IDCON) 6 % breakpoint -i 1 Brk00001 enable rammon.c#17 2 Brk00001 disable rammon.c#8 (IDCON) 7 % breakpoint -delete 1 2 Brk00001 disable rammon.c#8 User’s Manual U16525EJ1V0UM 233 CHAPTER 8 COMMAND REFERENCE cache • Name • Input format • Functions • Usage example Name cache - Setting of cache Input format cache cache config ?-icache itype? ?-dcache dtype? cache clear ?-icache bool? ?-dcache bool? Functions When config is specified for the subcommand, the cache type is set. When clear is specified for the subcommand, whether cache clear is to be done by EXEC, or not, is set (default is clear) When subcommand or below is omitted, the current status is displayed. itype is selected from the following: NB85E212 NB85E212 is used. NB85E213 NB85E213 is used. nouse Not used (default). dtype is selected from the following: 234 NB85E252 NB85E255 is used. NB85E263 NB85E263 is used. nouse Not used (default). User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE Usage example (IDCON) 1 % cache config -i NB85E212 -d NB85E252 (IDCON) 2 % cache i-cache: NB85E212 d-cache: NB85E252 (IDCON) 3 % cache clear -i false (IDCON) 4 % cache i-cache: NB85E212 (persist) d-cache: nouse User’s Manual U16525EJ1V0UM 235 CHAPTER 8 COMMAND REFERENCE dbgexit • Name • Input format • Functions • Usage example Name dbgexit - Terminating ID850NWC Input format dbgexit ?options? Functions Terminates the ID850NWC. The following are options: -saveprj Project is saved on terminating ID850NWC. Usage example (IDCON) 1 % dbgexit -saveprj 236 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE download • Name • Input format • Functions • Usage example Name download - Download of files Input format download ?options? filename ?offset? Functions Downloads file specified by filename according to options. If offset is specified, the address is shifted by the offset (if the data is in binary format, the load start address is specified for offset). -binary Binary format data is downloaded. -append Additional download is executed. -nosymbol Download is executed. Symbol information is not read. -reset CPU is reset after download. -information Download information is displayed. -symbolonly Symbol information is read. -erase The contents of the internal flash memory are erased all before download (only a product with internal flash memory). In default condition, they are not erased. Usage example (IDCON) 1 % download test.lmf User’s Manual U16525EJ1V0UM 237 CHAPTER 8 COMMAND REFERENCE extwin • Name • Input format • Functions • Usage example Name extwin - Creation of expansion window Input format extwin scriptfile Functions Creates expansion window with scriptfile. Usage example (IDCON) 1 % extwin d:/foo.tcl 238 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE finish • Name • Input format • Functions • Usage example Name finish - Returning from function Input format finish Functions Executes until it returns to the program that called the current function. Usage example (IDCON) 1 % finish User’s Manual U16525EJ1V0UM 239 CHAPTER 8 COMMAND REFERENCE go • Name • Input format • Functions • Usage example Name go - continuous execution Input format go ?options? Functions Executes the program continuously. When -waitbreak is specified, it waits for the program to stop. The following are options: -ignorebreak Breakpoint is ignored. -waitbreak The command waits for the program to stop. Usage example (IDCON) 1 % go -w 240 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE help • Name • Input format • Functions • Usage example Name help - Display of help Input format help Functions Displays Dcl help. Usage example (IDCON) 1 % help User’s Manual U16525EJ1V0UM 241 CHAPTER 8 COMMAND REFERENCE hook • Name • Input format • Functions • Usage example Name hook - Setting of hook Input format hook scriptfile Functions Sets the procedure for hook with scriptfile. Usage example (IDCON) 1 % hook d:/foo.tcl 242 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE ie • Name • Input format • Functions • Usage example Name ie - Display/setting of IE register Input format ie reg address ?value? ie dcu address ?value? Functions The ie command depends on the IE. When reg is specified for the subcommand, referencing and setting of the IE register is executed. When dcu is specified for the subcommand, referencing and setting of the IE register is executed. Caution The value of a register will be reset by 0 if a DCU register is referred to. Usage example (IDCON) 1 % ie reg 0x100 1 (IDCON) 2 % ie dcu 0x100 1 User’s Manual U16525EJ1V0UM 243 CHAPTER 8 COMMAND REFERENCE jump • Name • Input format • Functions • Usage example Name jump - Jump to window Input format jump -source -line filename ?line? jump ?options? address Functions Displays the window specified by options. -source The Source window is displayed from the address specified by address. -assemble The Assemble window is displayed from the address specified by address. -memory The Memory window is displayed from the address specified by address. -line The command is moved to the line specified by line. Usage example (IDCON) 1 % jump -s main (IDCON) 2 % jump -s -l mainfile.c 10 (IDCON) 3 % jump -m array 244 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE map • Name • Input format • Functions • Usage example Name map - Setting/deletion of memory mapping Input format map options address1 address2 ?accsize? Functions Sets, deletes, and displays memory mapping. The access size of 8, 16, or 32 is specified by accsize (the default is 8). The following are options: -target Target area is mapped. -protect I/O protect area is mapped. -clear All the settings for the mapping are deleted. -information Refer to the setting for the mapping. Usage example (IDCON) 1 % map -i 1: 0 0x7fff 8 {IROM} 2: 0x8000 0x87ff 8 {Target RRM} 3: 0x8800 0x9fff 8 {Target} 4: 0xa000 0xf7ff 8 {NonMap} 5: 0xf800 0xfaff - {NonMap} 6: 0xfb00 0xfedf 8 {Saddr} 7: 0xfee0 0xfeff 8 {Register} 8: 0xff00 0xffff 8 {SFR} (IDCON) 2 % map -c User’s Manual U16525EJ1V0UM 245 CHAPTER 8 COMMAND REFERENCE mdi • Name • Input format • Functions • Usage example Name mdi - Setting of expansion window Input format mdi geometry ?x y? width height mdi title string Functions Sets the size and title name of the expansion window. The command can be used only from the expansion window. Usage example (IDCON) 1 % mdi geometry 0 0 100 100 (IDCON) 2 % mdi title foo 246 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE memory • Name • Input format • Functions • Usage example Name memory - Display/setting of memory Input format memory ?options? address ?value? memory ?options? -fill address1 address2 value memory ?options? -copy address1 address2 address3 Functions Sets value in the memory of the address specified by address according to options. If value is omitted, display the value of the memory of the address specified by address. If -fill is specified, value is filled from address1 to address2. If -copy is specified, data from address1 to address2 is copied to address3. The following are options: -byte Displayed/set in one-byte units (default). -halfword Displayed/set in halfword units. -word Displayed/set in word units. -fill The data is filled in. -copy The data is copied. -noverify Verification is not executed on writing. Usage example (IDCON) 1 % memory 100 0x10 (IDCON) 2 % memory 100 2 (IDCON) 3 % memory 100 0x02 (IDCON) 4 % memory -fill 0 1ff 0 User’s Manual U16525EJ1V0UM 247 CHAPTER 8 COMMAND REFERENCE module • Name • Input format • Functions • Usage example Name module - Display of the list of files and functions Input format module progname ?filename? Functions Displays the list of files and functions of the load module specified by progname. If filename is not specified, the list of files is displayed. If filename is specified, the list of functions of the specified files is displayed. Usage example (IDCON) 1 % module rammon.lmf 1: rammon.c (IDCON) 2 % module rammon.lmf rammon.c 1: rammon.c sub1 2: rammon.c main 248 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE next • Name • Input format • Functions • Usage example Name next - Procedure step Input format next ?options? Functions Executes the procedure steps. If functions are called, the step stops after executing function. The following are options: -source Command is executed in source line units (default). -instruction Command is executed in command units. Usage example (IDCON) 1 % next -i (IDCON) 2 % next -s User’s Manual U16525EJ1V0UM 249 CHAPTER 8 COMMAND REFERENCE refresh • Name • Input format • Functions • Usage example Name refresh - Redrawing of window Input format refresh Functions Redraws the window and updates the data. Usage example (IDCON) 1 % batch foo.tcl (IDCON) 2 % refresh 250 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE register • Name • Input format • Functions • Usage example Name register - Display/setting of register value and I/O register value Input format register ?options? regname ?value? Functions Sets value in the register specified with regname. If value is omitted, displays the value of the register specified by regname. The following are options: -force Compulsory reading is executed. Usage example (IDCON) 1 % register pc 0x100 (IDCON) 2 % register pc 200 (IDCON) 3 % register pc 0x200 User’s Manual U16525EJ1V0UM 251 CHAPTER 8 COMMAND REFERENCE reset • Name • Input format • Functions • Usage example Name reset - Reset Input format reset ?options? Functions Resets the CPU, ID850NWC or symbols. If options are omitted, the CPU is reset. The following are options: -cpu CPU is reset (default). -debugger ID850NWC is reset. -symbol Symbol is reset. -event Event is reset. Usage example (IDCON) 1 % reset 252 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE run • Name • Input format • Functions • Usage example Name run - Reset and execution of CPU Input format run ?options? Functions Resets the program and executes it. If -waitbreak is not specified, the command does not wait until the program stops. The following are options: -waitbreak The command waits for the program to stop. Usage example (IDCON) 1 % run (IDCON) 2 % run -w User’s Manual U16525EJ1V0UM 253 CHAPTER 8 COMMAND REFERENCE step • Name • Input format • Functions • Usage example Name step - Step execution Input format step ?options? Functions Executes step execution. If functions are called, the command stops at the head of the functions. The following are options: -source The command is executed in source line units (default). -instruction The command is executed in command units. Usage example (IDCON) 1 % step -i (IDCON) 2 % step -s 254 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE stop • Name • Input format • Functions • Usage example Name stop - Stop executing Input format stop Functions Stops the program forcibly. Usage example (IDCON) 1 % run (IDCON) 2 % stop User’s Manual U16525EJ1V0UM 255 CHAPTER 8 COMMAND REFERENCE upload • Name • Input format • Functions • Usage example Name upload - Upload Input format upload ?options? filename address1 address2 Functions Saves the memory data within the specified range in a file. The following are options: -binary The data is saved in binary format. -intel The data is saved in Intel HEX format (default). -motorola The data is saved in Motorola HEX format. -tektronix The data is saved in Tektronix HEX format. -force The file is overwritten. Usage example (IDCON) 1 % upload -b foo.hex 0 0xffff (IDCON) 2 % upload -c -f foo.cov 0 0xffff 256 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE version • Name • Input format • Functions • Usage example Name version - Display of the version information Input format version Functions Displays the version information of the ID850NWC. Usage example (IDCON) 1 % version GUI : E2.00y [31-May-99] Devicefile : 78K0[uPD780034] E1.01a Debugger : 78K/0 Debugger E2.50c [02-Apr-99] Executer : 78K/0 Executer E1.3c Packet translator : 78K/0 Packet E2.00w Assembler : 78K/0 Asm/Disasm E1.15a [01-Apr-99] Tcl/Tk : 8.1.1 User’s Manual U16525EJ1V0UM 257 CHAPTER 8 COMMAND REFERENCE watch • Name • Input format • Functions • Usage example Name watch - Display/setting of variables Input format watch ?options? variable ?value? Functions Displays and sets the variables. The following are options: -binary The value is displayed in binary digits. -octal The value is displayed in octal digits. -decimal The value is displayed in decimal digits. -hexdecimal The value is displayed in hexdecimal digits. -string The value is displayed in character strings. -sizeof The size, instead of the value, of variables is displayed in decimal digits. Usage example (IDCON) 1 % watch var 0x10 (IDCON) 2 % watch -d var 16 (IDCON) 3 % watch array\[0\] 0xa 258 User’s Manual U16525EJ1V0UM CHAPTER 8 COMMAND REFERENCE where • Name • Input format • Functions • Usage example Name where - Trace of stack Input format where Functions Executes the back-trace of the stack. Usage example (IDCON) 1 % where 1: test2.c#sub2(int i)#13 2: test.c#num(int i)#71 3: test.c#main()#82 User’s Manual U16525EJ1V0UM 259 CHAPTER 8 COMMAND REFERENCE wish • Name • Input format • Functions • Usage example Name wish - Startup of Tclet Input format wish scriptname Functions Starts up the script using Tk (Tclet). The expansion window can be created with Tclet. Usage example (IDCON) 1 % wish test.tcl 260 User’s Manual U16525EJ1V0UM APPENDIX A N-WIRE CHECKER APPENDIX A N-WIRE CHECKER This chapter explains the following item about N-Wire Checker. • Overview • Operation • Explanation of each area and button • Corrective Actions in Case of NG • Restrictions A.1 Overview N-Wire Checker is an application for simply testing the PC connected N-Wire emulator and the target CPU operation. N-Wire Checker is installed at the same time as the ID850NWC. Figure A-1 N-Wire Checker User’s Manual U16525EJ1V0UM 261 APPENDIX A N-WIRE CHECKER The following tests are possible with N-Wire Checker. (1) N-Wire Emulator test Checks N-Wire emulator connection, initialization, and target CPU register read/write. The test results can be output to the log viewer and a log file. (2) DCK wave form test Outputs the data set from the N-Wire emulator to DDI signal in order to check the waveform of the DCK signal on the target board with an oscilloscope. A.2 Operation (1) Starting and preparation N-Wire Checker 1 A N-Wire emulator and a target board are turned on. Please refer to the user's manual of each N-Wire emulator about connection of a N-Wire emulator, a target board, and a host machine. 2 Select [Start] menu->[Program]->[NEC Tools32]->[N-Wire Checker]. This starts N-Wire Checker. If, at this time, the ID850NWC is already started up, end it. 3 Click the <device file> button. Specified a device file name of target CPU. 4 In the Emulator area, select the N-Wire emulator that is connected (IE-70000-MC-NW-A or IEV850E1-CD-NW). 5 In the Clock area, specify the frequency of the main clock input to the device (only when the IEV850E1-CD-NW is connected). 6 In the Internal ROM Security area, check the check box and input an ID code when a product with security unit is used in the single-chip mode (only when the IE-V850E1-CD-NW is connected). (2) N-Wire Emulator test 1 Press the <Test All> button. This is the same operation as pressing the <Connect>, <DCU reg>, and <CPU reg> buttons in sequence. 2 The test results (OK, NG) and log are displayed. Check that all the test are OK. Corrective Actions in Case of NG". For details of the dialog box, refer to "A.3 Explanation of each area and button". If NG is displayed, refer to "A.4 262 User’s Manual U16525EJ1V0UM APPENDIX A N-WIRE CHECKER (3) DCK waveform test 1 Connect the DCK signal of the target board to the oscilloscope probe. Caution Switch off the power supply of the N-wire emulator and target board before performing this connection. 2 Input 4-byte data (0xcccccccc at the time of shipping) in the DDI output signal for oscilloscope area and then click the <start> button. 3 Monitor the waveform on the oscilloscope. 4 Check whether the waveform noise (reflection) is within the standard range below. If it is not within the standard range"A.4 Corrective Actions in Case of NG". For details of the dialog box, refer to "A.3 Figure A-2 Explanation of each area and button". Waveform of N-Wire Checker VOH VOL VOH,VOL:Refer to the data sheet supplied with the emulator. Caution The data is output from the lowermost bit. -In the IE-70000-MC-NW-A If data from the target board changes, the changed data is subsequently output because data is shifted via the target board. -In the IE-V850E1-CD-NW Even if data from the target board changes, the same data is always output because data is shifted inside the emulator. User’s Manual U16525EJ1V0UM 263 APPENDIX A N-WIRE CHECKER A.3 Explanation of each area and button (1) device file (operating environment setting area) Object (2) Function <device file>button Displays the dialog box for specifying the device file name of the target CPU. Text area Displays the device file name of the target CPU and its path. Specify this at N-Wire Checker startup. Emulator(emulator selecting area) Object (3) Function IE-70000-MC-NW-A Select this to connect IE-70000-MC-NW-A. IE-V850E1-CD-NW Select this to connect IE-V850E1-CD-NW. Clock(frequency of the main clock setting area) Object Main OSC (4) (MH z ) Function Input the frequency of the main clock input to the device. Internal ROM Security (ID code specification area) Object (5) Function ID Code Check the check box when a product with security unit is used in the single-chip mode. Input area Input an ID code when a product with security unit is used in the singlechip mode. For details of the ID code, refer to the "IE-V850E1-CD-NW User's Manual". N-Wire emulator test (N-Wire emulator test area) Object 264 Function <Test All>button Tests Connect, DCR Reg, and CPU Reg in sequence. <Pause>button Pauses the test. (Testing resumes when this button is clicked again.) <Stop>button Stops the test. <Connect>button Opens communication with the target and executes testing for initialization. <DCU Reg>button Performs testing for DCU register read/write. <CPU Reg>button Executes testing for CPU register read/write. Text area A test result is displayed. User’s Manual U16525EJ1V0UM APPENDIX A N-WIRE CHECKER (6) (7) DCK wave form test (DCK waveform test area) Object Function DDI output signal for oscilloscope area Sets the data of the DDI signal output from the N-Wire emulator. When a value of 0xffffffff or greater is set, an error occurs when the <start> button is pressed. <start>button Outputs the value (0 to 0xffffffff) specified in the DDI output signal for oscilloscope text area. <stop>button Stops the signal for value testing specified in the DDI output signal for oscilloscope text area. Log viewer area Object (8) Function <log file> button Displays the dialog box for specifying the test result log file name. (Window\TEMP\IENWULT.log at the time of shipping) The log file is overwritten when N-Wire Checker is started up. The following occurs when the file path name is not specified. - When environment variable TEMP is not defined -> A log file is created under environment variable TMP. - When environment variable TMP is not defined -> A log file is created in the current folder. Text area Displays the log file name and its path. <clear>button Clears the log viewer display. If a log file name is specified in the log file text area, the log file contents are not cleared. Log viewer area Displays the test results as a log (up to approx. 21,000 characters). The same contents are output to the log file specified in the log file text area. Other Object <exit> button Function Ends N-Wire Checker. User’s Manual U16525EJ1V0UM 265 APPENDIX A N-WIRE CHECKER A.4 Corrective Actions in Case of NG (1) NG in N-Wire Emulator test If [Connect] is NG Take action to correct the error by referring to Table A-1 . Table A-1 Errors(N-Wire Checker) Error Number Error Messages Corrective Action 0x0100 Driver cannot be opened. The driver may not be correctly installed. Reinstall the driver. 0x0c43 Connection of emulator cannot be performed. In the IE-70000-MC-NW-A Check the power to the in-circuit emulator. Or, the PC-IF cable may not be correctly connected. Check the connection. In the IE-V850E1-CD-NW The switch setting may be wrong if a desktop computer is used and two or more PC cards are inserted. Check the setting. Or it may have malfunctioned. 0x03a0 Power supply of target is Check the target power supply. Check the cable OFF. connecting the in-circuit emulator and target board. Check that the VDD signal is input to the connector of the target board. 0x0c70 DCU cannot be accessed. Check the power to the chip. Check the connection of the signal lines (DCK, DMS, DDI, DDO, and DRSTZ). Check the noise level by a DCK waveform test. 0x0105 Failed in reading device file (dxxxx.800). The necessary file may be damaged. Reinstall the device file. 0x0c71 Reset cannot be performed. Check the clock signal. This may be caused by a stopped clock or a slow clock. 0x0c24 It cannot shift to debug mode. Check the clock signal. This may be caused by a stopped clock or a slow clock. 0x0c72 Monitor memory cannot be accessed. Check the noise level by a DCK waveform test. The problem may also be caused by an internal chip problem. 0x0c73 Monitor execution cannot be performed. Check the noise level by a DCK waveform test. The problem may also be caused by an internal chip problem. 0x0c74 CPU register cannot be accessed. Check the noise level by a DCK waveform test. The problem may also be caused by an internal chip problem. 0xf603 Incorrect ID Code. Input the correct ID code (IE-V850E1-CD-NW). 0xf604 Incorrect ID Code. Abort the N-Wire checker. Input the correct ID code (IE-V850E1-CD-NW). If [DCU reg] is NG Normal access to the DCU register seems impossible. Perform the DCK waveform test. If no anomaly is found with the DCK waveform test, the register may be damaged, so try again with a different chip . 266 User’s Manual U16525EJ1V0UM APPENDIX A N-WIRE CHECKER If [CPU reg] is NG Normal access to the CPU register seems impossible. Perform the DCK waveform test. If no anomaly is found with the DCK waveform test, the register may be damaged, so try again with a different chip. (2) NG in DCK waveform test Check the following items regarding the design of the target board, in accordance with the User's Manual of the N-Wire emulator. In the IE-70000-MC-NW-A • Is the pattern of the N-Wire interface signal 100 mm or less? • Is the DCK signal shielded through a 4.7 k Ohm pull-up resistor + GND? • Is a 4.7 k Ohm pull-up resistor connected to the DMS signal and the DDI signal? • Is a 22 Ohm damping resistor connected to the DDO signal? • Is a 50 k Ohm pull-down resistor connected to the DRSTZ signal? In the IE-V850E1-CD-NW • Is the pattern of the N-Wire interface signal 100 mm or less? • Is the DCK signal shielded through a pull-up resistor* + GND? • Is a pull-up resistor* connected to the DMS, DDI, and DDO signals? • Is a damping resistor* connected to the DDO signal? • Is a pull-down resistor* connected to the _DRSTZ signal (or DRST signal)? Caution The resistance of the resistor marked * above must be as specified for each device. Some devices have on-chip pull-up/down resistors. With these devices, an external resistor is not necessary. Also check the following items regarding the power supply capacity of the target board. • Is a power supply with a sufficient capacity used? • Are sufficient capacitors provided on the target board? • Is a bypass capacitor connected to all the power supply pins of the CPU? • Is the GND plane on the target board sufficiently large? A.5 Restrictions Up to 21000 characters can be displayed in the log view area. If this is exceeded, the displayed information is overwritten starting from the oldest data. if the system resources are running extremely short, the N-Wire Checker stops output to the log view area. For accurate information, therefore, use the log file. Information is continuously recorded in the log file even while screen output is stopped. The log file is overwritten once when the N-Wire checker is started. User’s Manual U16525EJ1V0UM 267 APPENDIX B EXPANSION WINDOW APPENDIX B EXPANSION WINDOW This chapter explains the following item about Expansion Window. • Overview • Activation • Explanation of each sample window B.1 Overview With the ID850NWC, the user can create custom windows in addition to the existing windows. The Tcl (Tool Command Language) interpreter and the commands for controlling the debugger are implemented in the ID850NWC. Users can create windows using this Tcl. The ID850NWC is supplied with samples of the following expansion windows. Table B-1 List of Expansion Window Window Name B.2 Function List window Displays a list of the source files and functions. Grep window Searches a character string. RRM window This is the memory window for real-time RAM monitoring. Hook window Sets the hook procedure. Memory Mapped I/O window Writes to or reads from the specified address only. Activation The expansion window can be activated by selecting List, Grep, RRM, Hook, or Memory in [Others] on the [Browse] menu. Remark B.3 268 Each .tcl file is installed in NECTools32\BIN\idtcl\tools. Explanation of each sample window User’s Manual U16525EJ1V0UM APPENDIX B EXPANSION WINDOW List window The lists of the source files and functions are displayed in a tree format in this window. When a function name in the list is clicked, the corresponding source is displayed. Figure B-1 List Window When a function name in the list is clicked, the corresponding function portion is displayed in the Source window. User’s Manual U16525EJ1V0UM 269 APPENDIX B EXPANSION WINDOW Grep window Search for a character string is performed in the files under the source path. When the search result is clicked, the corresponding source is displayed. Figure B-2 Grep Window By clicking a character string line in the search result, the corresponding character string portion is displayed in the Source window. Object 270 Function Pattern Input the character string to be searched. <Mark>button Marks the searched character string. <Clear>button Clears the marking <Jump>button Put the cursor on a section in the search result and click this button to open the corresponding file Match Case Select whether or not to distinguish uppercase and lowercase. Filter Specify the type of the file to be searched. User’s Manual U16525EJ1V0UM APPENDIX B EXPANSION WINDOW RRM window This is a dedicated window for RAM monitoring. The address area in which a value was changed in the RAM area during program execution is highlighted with a color. The display range is 1 KB. With reading RAM, execution of the user program momentarily breaks. On this window, the start address of the RAM area can be changed while the user program is being executed. Caution 1 All data are not read at the same time (because data of 1 KB is divided and read in word units). Caution 2 The sampling interval is about 0.3 - 0.7 seconds (20MHz), but it depend on the frequency of the CPU operation. Caution 3 This RRM window is opened even when the RAM monitor function is set to OFF in the Extended Option dialog box. Figure B-3 RRM Window Object Function Address Input the start address to be displayed (automatically aligned to 1 KB.) <Change>button Switch the start address display. <Refresh>button Reads data from the memory <Color>button The color can be customized. The default color is red. Keep Color Specify whether or not to hold the color highlighting. Selected: Once a value is changed, the color highlighting is held until a break occurs. Unselected: The color is cleared if there is no change of values(default). <Close>button Closes this window. User’s Manual U16525EJ1V0UM 271 APPENDIX B EXPANSION WINDOW Hook window This window is used to set a hook to the debugger, using a hook procedure. The hook procedure enables changing the register value before downloading a program, or after a CPU reset. On this window, a hook can be set by using the following four tabs. [BeforeDownload] tab: Hook before downloading [AfterCpuReset] tab: Hook after CPU reset [BeforeCpuRun] tab: Hook before start of execution [AfterCpuStop] tab: Hook after break By setting a peripheral I/O register by using the [BeforeDownload] tab before downloading the load module, for example, downloading can be executed at high speeds. Access to the external memory is also facilitated by using this tab. If the setting is saved as "project-file-name.tcl" in the directory where the project is stored, the setting is executed when the project is next opened. Figure B-4 Hook Window Object 272 Function [BeforeDownload] tab Hook before downloading Before downloading is performed, the register values input to the tab are automatically overwritten by the specified value. [AfterCpuReset] tab Hook after resetting CPU after resetting CPU, the register values input to the tab are automatically overwritten by the specified value. [BeforeCpuRun] tab Hook before starting execution before starting execution, the register values input to the tab are automatically overwritten by the specified value. User’s Manual U16525EJ1V0UM APPENDIX B EXPANSION WINDOW Object Function [AfterCpuStop] tab Hook after breaking After breaking, the register values input to the tab are automatically overwritten by the specified value. <Test> button All the commands described on the tabs are tested. <Save>button Saves all the tab contents to a file. If the ID850NWCwas activated from a project file, the file is saved as "project-file-name.tcl". <Clear> button Clears all the descriptions on the tabs. Caution Specify the program register and the peripheral I/O register for the register name. User’s Manual U16525EJ1V0UM 273 APPENDIX B EXPANSION WINDOW Memory Mapped I/O window Data is explicitly read or written at a specified address in this window. When a write is performed in the Memory window, the data is internally read and verified by the ID850NWC. In addition, the memory can also be read simply by scrolling in the Memory window. On the Memory Mapped I/O window, however, the above operations are not performed. Therefore, this window is useful for reading or writing a specific address. While the user program is being executed, it momentarily breaks before data is written in this window. Figure B-5 Memory Mapped I/O Window Object 274 Function Address Input the address to display. The display target address changes by pressing the Enter key or clicking the <Jump> button.The data contents are not read at this time, so the address (numerical value) is displayed in the address display section, but "XX" is displayed in the data section. <Jump> button Jumps to the address input in the Address field. <Refresh All> button Reads all the areas currently displayed only once "ZZ" will be displayed in the data section when an attempt is made to read an unmapped area, or when an error occurs upon a read. <Refresh One> button Reads data in the memory of the address at which the cursor is placed only once. The read data size depends on the display format. "ZZ" will be displayed in the data section when an attempt is made to read an unmapped area, or when an error occurs upon a read. <Modify...>button Opens the Memory Mapped I/O dialog box. The address at which the cursor is placed is the input address displayed in the Memory Mapped I/O dialog box.If this button is clicked after the cursor position is changed in the Memory Mapped I/O dialog box, the Address field in the Memory Mapped I/O dialog box is also changed. <Close>button Closes this window. Right-click menu Select the display format from Byte, HalfWord, and Word. User’s Manual U16525EJ1V0UM APPENDIX B EXPANSION WINDOW Memory Mapped I/O dialog box This dialog box can be opened by clicking the <Modify... > button on the Memory Mapped I/O window. It is used to write data to any address. Caution 1 When the area to which data is written is displayed in the Memory window or Watch window , data is read in these windows after the <Write in> button is clicked. Caution 2 If Data Size is less than Access Size specified in the Configuration dialog box, ID850NWC reads data in Access Size once, changes the corresponding part of the read data, and writes the changed data in Access Size. Figure B-6 Memory Mapped I/O Dialog Box Object Function Address Input the address to be written. The address corresponding to the data for which the cursor is placed in the Memory Mapped I/O window is displayed. Value Input the value to be written. Data Size Select the size of the data to be written. The size specified in the Memory Mapped I/O window is selected by default. <Write in> button Data is written to the specified address with the specified size. <Close> button Closes this dialog box. User’s Manual U16525EJ1V0UM 275 APPENDIX C INPUT CONVENTIONS APPENDIX C INPUT CONVENTIONS This appendix explains the input conventions of the following items: • Character set • Symbols • Numeric Values • Expressions and Operators C.1 Character set The characters listed in Table C-1 can be used as the character set. The characters listed in Table C-2 can be used as special characters. Specify a line number as an integer constant, starting from 1. Table C-1 Usable Character Set Classification Character Alphabetic characters Uppercase characters: A B C D E F G H I J K L M N O P Q R S T U V X W Z Lowercase characters: a b c d e f g h I j k l m n o p q r s t u v x w z Numerals 0123456789 Character equivalent to alphabetic character @_ Table C-2 Character 276 List of Special Characters Name Usage ( Left parenthesis Changes operation order. ) Right parenthesis Changes operation order. + Plus Addition operator or positive sign - Minus Subtraction operator or negative sign * Asterisk Multiplication operator or indirect reference operator / Slash Division operator % Percent Remainder operator ~ Tilde Complement operator | Vertical line Bit sum operator ^ Circumflex Bit difference operator & Ampersand Bit product operator or address operator [ Left bracket Array subscript operator or base register specification symbol ] Right bracket Array subscript operator or base register specification symbol User’s Manual U16525EJ1V0UM APPENDIX C INPUT CONVENTIONS Table C-2 Character C.2 List of Special Characters Name Usage . Period Direct member operator or bit position specifier , Comma Delimiter between operands Symbols The following rules apply to symbols: 1 A symbol consists of characters A to Z, a to z, @, _ (underbar), . (period), and 0 to 9. 2 A symbol must start with a character other than numerals 0 to 9. 3 Uppercase characters (A to Z) and lowercase characters (a to z) are distinguished. 4 A symbol must be no more than 256 characters long (if a symbol of more than 265 characters is defined, only the first 256 characters are valid). 5 A symbol is defined by loading a load module file. 6 Symbols are classified into the following types by the valid range: - Global symbol (assembly language, C language) - Static symbol (C language) In-file static symbol In-function static symbol - Local symbol (C language) In-file local symbol In-function local symbol In-block local symbol 7 The following symbols are available for each language used: - Assembly language Label name - C language Variable name (including pointer function name, enumeration type variable name, array name, structure name, and union name) Function name, label name Array element, structure element, union element, bit field (if the symbol is an array, structure, or union) 8 A symbol can be described instead of an address or numeric value. 9 The valid range of a symbol is determined based on the source debug information when the source file is assembled or compiled. 10 Describe only the symbol name of a global symbol. 11 A local symbol is expressed in pairs with a file name. C.3 Numeric Values The following four types of numeric values can be used. The input format of each type is as shown User’s Manual U16525EJ1V0UM 277 APPENDIX C INPUT CONVENTIONS below. The suffix (bold) and the alphabetic characters of hexadecimal numbers may be uppercase or lowercase characters. If the first character is A to F, 0 must be prefixed to it. In the input field of the debugger, decimal numbers or hexadecimal numbers are alternately selected, depending on the default radix. Table C-3 Input Format of Numeric Values numeric value C.4 Input format Binary number nY n...nY (n=0,1) Octal number nO n...nO (n=0,1,2,3,4,5,6,7) nQ n...nQ (n=0,1,2,3,4,5,6,7) Decimal number n n...n nT n...nT (n=0,1,2,3,4,5,6,7,8,9) Hexadecimal numbers n n...n nH n...nH 0xn 0xn...n (n=0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,F) Expressions and Operators Expressions An expression consists of constants, register names, IOR names, and symbols coupled by operators. If an IOR name, label name, function name, or variable name is described as a symbol, an address is calculated as the value of the symbol. The elements making up an expression, except operators, are called terms (constants and labels). Terms are called the first term, the second term, and so on, starting from the left. Operators The following operators of the C language can be used: Table C-4 Symbol List of Operators Meaning Explanation Operators 278 + Addition Returns the sum of the first and second terms. - Subtraction Returns the difference between the first and second terms. * Multiplication Returns the product of the first and second terms. / Division Divides the value of the first term by the value of the second term, and returns the integer of the result. User’s Manual U16525EJ1V0UM APPENDIX C INPUT CONVENTIONS Table C-4 Symbol List of Operators Meaning Explanation MOD % Remainder Divides the value of the first term by the value of the second term, and returns the remainder of the result. - sign Unary operator (negative) Returns 2's complement of the value of the term. + sign Unary operator (positive) Returns the value of the term. Logical operator NOT ~ Negation Logically negates each bit of the term, and returns the result. AND & Logical product Obtains the logical product of the values of the first and second terms on each bit, and returns the result. OR | Logical sum Obtains the logical sum of the values of the first and second terms on each bit, and returns the result. XOR ^ Exclusive logical sum Obtains the exclusive logical sum of the values of the first and second terms on each bit, and returns the result. SHR >> Right shift Shifts the value of the first term by the value (number of bits) of the second term to the right, and returns the result. As many 0s as the number of shifted bits are inserted in the higher bits. SHL << Left shift Shifts the value of the first term by the value (number of bits) of the second term to the left, and returns the result. As many 0s as the number of shifted bits are inserted in the lower bits. Shift operator Byte separation operator HIGH Higher byte Of the lowest 16 bits of the term, returns the higher 8 bits. LOW Lower byte Of the lowest 16 bits of the term, returns the lower 8 bits. Word separation operator HIGHW Higher word Of the 32 bits of the term, returns the higher 16 bits. LOWW Lower word Of the 32 bits of the term, returns the lower 16 bits. ( Left parenthesis ) Right parenthesis Performs the operation in ( ) before the operation outside ( ). '(' and ')' are always used in pairs. Other Rules of operation Operations are performed according to the priority of the operators. Table C-5 Priority 1 Higher Operator Priority Operators (, ) User’s Manual U16525EJ1V0UM 279 APPENDIX C INPUT CONVENTIONS Table C-5 Operator Priority Priority Operators 2 + sign, - sign, NOT, , HIGH, LOW, HIGHW, LOWW 3 *, /,, MOD, %, SHR, >>, SHL, << 4 +, - 5 AND, & 6 Lower OR, |, XOR, ^ • If the priorities of the operators are the same, the operation is performed from the left toward the right. • Performs the operation in ( ) before the operation outside ( ). • Each term in an operation is treated as unsigned 32-bit data. • All operation results are treated as unsigned 32-bit data. • If an overflow occurs during operation, the lower 32 bits are valid, and the overflow is not detected. Terms To describe a constant for a term, the following numeric values can be described. Table C-6 Range of Radixes Radix 280 Range Binary number 0Y <= value <= 1111111111111111111111111111111Y (32 digits) Octal number 0O <= value <= 37777777777O Decimal number -2147483648 <= value <= 4294967295 (A negative decimal number is internally converted into a 2's complement.) Hexadecimal numbers 0H <= value <= 0FFFFFFFH User’s Manual U16525EJ1V0UM APPENDIX D TERMINOLOGY APPENDIX D TERMINOLOGY The major terms used throughout this manual are as follows: • Current window • Delimiter (separator) • Program • File • Function • Structure • Stack frame number • Line D. 1 Terminology Current window The current window is the window you are now in and operating by means of key input and menu selection. Delimiter (separator) The following separators can be used as the delimiter of file names, function names, variable names, and line numbers. Table D-1 Delimiter Delimiter Meaning # Used as a separator of file names, variable names, function names, and line numbers. $ Used as a separator of load module names, file names, variable names, and function names. Program A program is the execution unit to be debugged. The debugger manages each one of the load module files specified on downloading as a program. To specify a program name, use a load module file name on downloading. Current program The current program is the program that contains the instruction currently breaking execution (instruction indicated by the PC). When specifying a file in the current program, the program name may be omitted. File Up to 127 characters can be handled in a file name with path. Depending on the type of file, however, a file name of more than 127 characters can be specified. User’s Manual U16525EJ1V0UM 281 APPENDIX D TERMINOLOGY Current file The current file is the source file that contains the instruction currently breaking execution (instruction indicated by the program counter (PC)). When specifying a line or function in the current file, the file name may be omitted. Function Indicates the functions constituting a C source program. Current function The current function is the function that contains the instruction currently breaking execution (instruction indicated by the program counter (PC)). When accessing a local variable in the current function, specifying the function name may be omitted. Structure Structures and unions in C language are called structures. The name structure is used if a structure or union variable is used without members explicitly specified. Stack frame number The stack frame number is a decimal integer starting from 1 and is assigned to the stack contents. The shallower the nesting level of the stack, the higher the number. A function having a stack number one less than that of a certain function is the function that calls the certain function. Line A line is specified in order to identify one line in the source file. Specify a line number as an integer constant, starting from 1. 282 User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES APPENDIX E MESSAGES This appendix explains the following item about messages displayed in the Error/Warning dialog box of the ID850NWC. • Display format • Error messages at startup • Fatal error messages • Syntax error messages • Warning message or question message E.1 Error/Warning Messages E. 1. 1 Display format Messages from the ID850NWC are generated and output to the Error/Warning dialog box when "information that should be informed to users (fatal error, syntax error, and warning or questions)" is detected while the debugger is executing processing. The product name is displayed on the title bar of the dialog box. Figure E-1 Error/Warning Messages There are three types of messages in the ID850NWC (fatal error message, syntax error message, and warning message or question message). A : Fatal error messages When a fatal error is detected in the debugger, a message is output to the Error dialog box before aborting the processing and terminating the ID850NWC. F : Syntax error messages When a syntax error is detected in the ID850NWC, a message is output to the Error dialog box before aborting the processing. At this time, opened windows and dialog boxes are closed. W : Warning message or question message When a warning or question is detected in the ID850NWC, a message is output to the Warning dialog box before aborting the processing. User’s Manual U16525EJ1V0UM 283 APPENDIX E MESSAGES E. 1. 2 Error messages at startup The errors listed in next table may be output when the ID850NWC is started up. If such an error is output, fix the problem by following the indicated corrective action. F0100: 1) The driver may not be correctly installed. Reinstall the driver. F0c43: 1) Driver cannot be opened. Connection of emulator cannot be performed. The switch setting may be wrong if a desktop computer is used and two or more PC cards are inserted. Check the setting. W03a0: 1) Or it may have malfunctioned. Power supply of target is OFF. Check the target power supply. Check the cable connecting the in-circuit emulator and target board. Check that the VDD signal is input to the connector of the target board. F0c70: 1) DCU cannot be accessed. Check the power to the chip. Check the connection of the signal lines (DCK, DMS, DDI, DDO, and DRSTZ). Check the noise level by a DCK waveform test on the N-WIRE CHECKER. F0105: 1) The necessary file may be damaged. Re-install the device file. F0c71: 1) It cannot shift to debug mode. Check the clock signal. This may be caused by a stopped clock or a slow clock. F0c72: 1) Reset cannot be performed. Check the clock signal. This may be caused by a stopped clock or a slow clock. F0c24: 1) Failed in reading device file (dxxxx.800). Monitor memory cannot be accessed. Check the noise level by a DCK waveform test on the N-WIRE CHECKER. The problem may also be caused by an internal chip problem. F0c73: 1) Monitor execution cannot be performed. Check the noise level by a DCK waveform test on the N-WIRE CHECKER. The problem may also be caused by an internal chip problem. F0c74: 1) CPU register cannot be accessed. Check the noise level by a DCK waveform test on the N-WIRE CHECKER. The problem may also be caused by an internal chip problem. 284 User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES F0c23: 1) E. 1. 3 Bus hold under continuation. Check the setting of the target board, or mask the HOLD pin. Fatal error messages A list of the messages that are output when fatal errors are detected while the ID850NWC is executing processing is shown below in numerical order. A0101: Can not find initialization file (expc.ini). A0102: Host name not found. A0105: Failed in reading device file (d3xxx.800). 1) Necessary files may be damaged. Reinstall the device file. A0106: 1) Illegal data received. Check the power of the in-circuit emulator, cable connections, and setting of the interface board and restart the ID850NWC. A01a1: Failed in reading ie703000.ie. A01a2: Break board is not connected. A01a3: Emulation board is not connected. A01a4: Board configuration of ICE is not consistent. A01a5: POD/EM1 board is not connected. A01a6: Executor is running. A01a8: Failed in reading initialization file (expc.ini). A04a1: Not enough memory for emulation. A0600: Not enough memory for buffer. 1) There is not enough system memory. Close the applications being executed and the open files. A0c01: 1) During access of register, CPU did timeout. Check the clock signal, etc. The register value may not be correct. A0c02: During access of memory, CPU did timeout. User’s Manual U16525EJ1V0UM 285 APPENDIX E MESSAGES 1) Check the HOLD signal, WAIT signal, clock signal, etc. The memory value may not be correct. A0c03: 1) Check the HOLD signal, WAIT signal, clock signal, etc. The IOR value may not be correct. A1000: Failed in initializing ICE. A1001: No entry exists for specified number. A1002: Can not relocate internal RAM. A1005: Illegal relocation address. A1007: Not enough memory on ICE. A1008: Not enough memory for tables. 1) There is not enough system memory. Close the applications being executed and the open files. A1009: Already initialized. A100a: Not initialized. A1015: Programmable-IOR does not exist. A10ff: Can not communicate with ICE. A1dbe: Error occurred inside debugger. A2001: Illegal address. A2009: Device file is damaged or error is in file. A200b: Can not copy. A200c: Not enough memory. 1) 286 During access of I/O register, CPU did timeout. There is not enough system memory. Close the applications being executed and the open files. A20ff: Can not communicate with ICE. A2222: Illegal condition. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES A3012: 1) Not enough memory. There is not enough system memory. Close the applications being executed and the open files. A30ff: Can not communicate with ICE. A4011: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. A4018: 1) Not enough memory. There is not enough system memory. Close the applications being executed and the open files. A5000: Illegal device file type. A5001: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. A5002: Can not open device file. A5003: Reading of device file went wrong. A5004: Can not close device file. A5005: Illegal device file format. 1) Necessary files may be damaged. Reinstall the device file. A5006: Failed in initializing ICE. A5007: Device file has broken or error is in a file. A500c: Failed in reading expc.ini. A500d: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. A5300: Illegal device file type. A5301: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. A5302: 1) Can not open database file. Necessary files may be damaged. Reinstall the ID850NWC and device file. User’s Manual U16525EJ1V0UM 287 APPENDIX E MESSAGES A5303: Reading of database file went wrong. A5304: Can not close database file. A5305: Illegal database file format. 1) Necessary files may be damaged. Reinstall the ID850NWC, and device file. A5306: Database information has been already initialized. A5307: Database information does not exist. A7012: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. A70fe: 1) CPU is in the bus-hold status. Reset the ID850NWC. A70ff: Can not communicate with ICE. A7f03: Failed in canceling RUN/STEP. A9000: Specified register symbol does not exist. A9001: Specified register symbol ID does not exist. A9003: Illegal condition. A9004: Too large register size. Aa005: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. Aa00b: Can not close file. Aa00c: Failed in reading file. 1) 288 Bus hold error. The file is damaged or does not exist. Recreate the file. Aa010: Can not communicate with ICE. Aa013: Reading of file went wrong. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES Ab009: 1) Not enough memory. There is not enough system memory. Close the applications being executed and the open files. Ab00d: Current function does not exist. Ab00e: Current line does not exist. Ab00f: Tag not found. Ab010: Failed in loading symbol table. Ab011: Illegal line number. Ab015: Reading of file went wrong. 1) The file is damaged or does not exist. Recreate the file. Ab016: 1) The file is damaged or does not exist. Recreate the file. Ab017: 1) Can not open file. Failed in writing file. The file is damaged or does not exist. Recreate the file. Ab019: Reading of file went wrong. Ab01a: Can not close file. Ab01c: Too many entries of the task kind . Ab023: Current stack frame is not active. Ab024: Different section. Ab02a: Can not communicate with ICE. Ab030: Monitor timed out. 1) Check the power of the in-circuit emulator, cable connections, and setting of the interface board and restart the ID850NWC. Ab031: Already set in memory. User’s Manual U16525EJ1V0UM 289 APPENDIX E MESSAGES Ab032: Out of scope. Ab033: LP is not stored. Ab039: Failed in loading debug information. Ab03a: No more section information. Ab041: Specified file is not load module. Ac002: Can not close file. Ac003: Reading of file went wrong. 1) The file is damaged or does not exist. Recreate the file. Ac004: Reading of file went wrong. Ac009: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. Ac010: Can not communicate with ICE. Ad000: Error occurred inside debugger. Ad001: Not enough memory. 1) There is not enough system memory. Close the applications being executed and the open files. Ad002: Failed in reading initialization file (expc.ini). Ad003: ICE is not connected. Ae008: Not enough memory 1) There is not enough system memory. Close the applications being executed and the open files. Af000: 1) There is not enough system memory. Close the applications being executed and the open files. Af604: 290 Not enough memory. Incorrect ID Code. Abort the debugger. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES E. 1. 4 Syntax error messages A list of the messages that are output when syntax errors are detected while the ID850NWC is executing processing is shown below in numerical order. F0002: This feature is not supported. F0103: Data transfer to ICE is timed out. Please confirm the power of ICE, connection of the interface cable, or I/O address of the PC interface board. F0104: Data receive from ICE is timed out. Please confirm the power of ICE, connection of the interface cable, or I/O address of the PC interface board. F01a0: No response from the evachip. Please confirm the signal of the CLOCK or RESET WAIT, HLDRQ and so on. F0200: 1) No mapped address was accessed. External memory could not be accessed, as it is not set. Change the register values necessary for accessing the external memory using the IOR window or Hook Procedure before download (Refer to "To change the value of a register required for access of an external memory"). F02a0: 1) Bus hold error. CPU is in the bus-hold status. Reset the debugger. F02a2: Can not compulsory break. F02d2: Not enough memory for trace-buffer. F0300: User program is running. F0301: User program is being breaked. F0302: User program is being traced. F0303: Not traced. F0304: Trace memory is not set. F0306: No trace block exists. F0307: No event condition exists. User’s Manual U16525EJ1V0UM 291 APPENDIX E MESSAGES F0308: No timer measurement is done. F0309: No trigger frame exists. F030a: Tracer is being stopped. F030b: Specified snap-event has not been registered. F030c: Specified stub-event has not been registered. F030d: Timer is running. F030e: Memory copy area is overlapped. F030f: Trace has been already set. F0310: Event condition is not set. F0311: Too many valid timer event conditions. F0312: Specified timer event is not set. F0313: illegal map range. 1) Check the setting in "Memory Mapping (mapping setting area)" in the Configuration dialog box. When mapping to external memory has been performed, change the register values necessary for accessing the external memory using the IOR window or Hook Procedure before download (Refer to "To change the value of a register required for access of an external memory"). 292 F0314: Only trace delay mode can set with delay trigger. F0315: Delay trigger cannot set without trace delay mode. F03a1: Step execution is being done. F03a2: Timer and Tracer are running. F03d0: Back-trace is being executed. F03d1: Back-trace is being stopped. F03d2: Back-trace execution point overrun oldest frame. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES F03d3: Register status or Memory status cannot be set up other than Phase1 of event link. F03d4: No back-trace information exists. F03d5: Last command can not be backstepped. F0400: Illegal condition. 1) Settings of the used in-circuit emulator and those of the Configuration dialog box may not match. Check the Chip selection of "Chip (CPU selection area)". F0401: Result of timer measurement overflowed. F0402: Too many event conditions with path count. F0403: Too many address range conditions. F0404: Too many simultaneously-usable-event conditions. F0405: Too many snap-events. F0406: Too many stub-events. F0407: Too many initialization data. F0408: Too large search data (> 16 byte). F0409: Too large search data (> search range). F040a: Too many Linking-event conditions. F04a0: Software break conditions number overflow. F04a2: Too many partition of bus size. F04a3: Too many execution-event conditions. F04a4: Too many bus-event conditions. F0b61: Section Trace event conditions overflow. User’s Manual U16525EJ1V0UM 293 APPENDIX E MESSAGES F0c00: 1) Monitor file read error. Necessary files may be damaged. Reinstall the ID850NWC. F0c20: Guarded area can not be accessed. F0c21: Memory was unready status. F0c25: Flash macro service ROM was accessed or stepped in. F0c26: FLMD terminal is in a write-protected state. 1) FLMD is not in the write-enabled status. Check the status of the FLMD0 and FLMD1 pins. Check the clock signal. The possible causes are that the clock is stopped or the clock is slow. F0c27: 1) Security flag is in a write-protected state. The security flag of the flash memory has disabled writing, block erasure, or chip erasure. Nothing can be written to the flash memory. F0c28: 1) 294 Internal RAM is not enough, the writing to flash memory is not made. The internal RAM size is less than 4 KB and flash self-programming cannot be executed. F0c29: The blank check of flash memory failed. F0c2a: The erasing of flash memory failed. F0c2b: The writing of flash memory failed. F0c2c: The internal verification of flash memory failed. F0c40: Status of effective event conditions cannot be changed. F0c41: Coverage test is being executed. F0c60: Event before execution cannot be set up other than break conditions. F0c61: Can not register event numbers which can not be used for hardware break. F0c62: Event numbers reserved for hardware breaks can not be used. F0c63: Event link conditions cannot set. F0c64: Too many ROM-emulation-RAM areas. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES F0ca0: Can not communicate with ICE. Please confirm the power of ICE, connection of the interface cable, or I/O address of the PC interface board. 1) Can not communicate with in-circuit emulator. Check the power of the in-circuit emulator, cable connections, and setting of the interface board etc. F0ca1: 1) Monitor file not found. Necessary files may be damaged. Reinstall the ID850NWC. F1003: Illegal relocation address. F1004: Illegal condition F1006: Illegal address. F100b: User program is running. F100c: Different bus size has been already specified. F100d: Too large bus size. F100e: Too large bus partition size. F100f: Target is not turned on. F1010: Illegal map range. F1011: Failed in setting internal ROM and RAM. F1012: This feature is not supported. F1013: No terminal name. F1016: Programmable-IOR does not movable. 1) Necessary files may be damaged. Reinstall the latest device file. F1017: I/O Protect mapping is possible a target attribute only. F1018: Illegal Internal ROM size. F1019: Illegal Internal ROM size or Internal RAM size. User’s Manual U16525EJ1V0UM 295 APPENDIX E MESSAGES F2000: Illegal I/O register name. F2002: User program is running. F2003: Illegal I/O register number. F2004: Illegal bit number. F2006: Hidden I/O register was specified. F2007: I/O register of ban read/write was specified. F2008: I/O register not existing was specified. F200a: Illegal value specified for I/O register. F3000: No mapped address was accessed. 1) The allocation addresses of the program and the addresses of the ID850NWC may not match. Set the mapping to the external memory in "Memory Mapping (mapping setting area)" in the Configuration dialog box according to the allocation addresses specified in the link directive file on compilation. When mapping to external memory has been executed, change the register values necessary for accessing the external memory using the IOR windowor Hook Procedure before download (Refer to "To change the value of a register required for access of an external memory"). 296 F3001: Memory has different value. F3002: Illegal start address. F3003: Illegal end address F3004: Illegal start address and end address. F3005: Illegal condition. F3006: User program is running. F3007: Verification error. F3008: No condition specified. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES F3009: Parameter size does not align with access size alignment. F300a: Specified address does not align with access size alignment. F300b: Source address does not align with access size alignment. F300c: Destination address does not align with access size alignment. F300d: Illegal end address. F300e: Different access size in specified area. F300f: Different access size both in source and destination areas. F3010: Different access size in destination area. F3011: Different access size, source & destination. F3013: Failed in writing DMM. F3014: Oveflowed mapping area. F3015: Processing was interrupted. F3016: This feature is not supported. F4000: Can not delete specified event. 1) The specified event cannot be deleted as it is being used under another condition. Invalidate it for other usages before deleting. F4001: Illegal table number. F4002: Illegal start address. F4003: Illegal end address. F4004: Illegal status. F4005: Illegal data. F4006: Specified event number has been already used. User’s Manual U16525EJ1V0UM 297 APPENDIX E MESSAGES 298 F4007: Too many same events are registered. F4008: Specified event has not been registered. F4009: Illegal data size. F400a: Illegal mode. F400b: Setting value is inaccurate. F400c: Event link conditions cannot be used for section trace conditions. F400d: Too many identical events are registered (>= 32767). F400e: Specified event condition does not exist. F400f: Illegal event link condition. F4010: Function not found. F4012: Timer is being disabled. F4014: Can not use software break. F4015: Can not use event condition specifying address range. F4016: Can not change event condition. F4017: Can not access word at odd address. F4019: This feature is not supported. F401a: No Event. F401b: Can not use tag-event. F401d: Start event and end event of timer are not made to the same setup. F401e: Too many trace-events. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES F401f: Path count cannot be set up. F4020: Address range cannot be set up in event before execution. F4021: Event conditions number overflow. F4022: Software DMM conditions number overflow. F4023: Real-time call conditions number overflow. F4024: Software break call conditions number overflow. F4025: Illegal snap condition. F4026: Too many event conditions cannot be set as Phase1 and Phase2 of event link conditions. F4027: Software break conditions number which can be set as internal ROM was overflow. F4318: Illegal memory bank setting. F5008: Can not open device file. 1) Necessary files may be damaged. Reinstall the device file. F5009: Can not open ie703000.ie. F500a: Specified device file is illegal version. 1) Necessary files may be damaged. Reinstall the device file. F5308: 1) Necessary files may be damaged. Reinstall ID850NWC. F5309: 1) Can not open specified database file. Specified database file is illegal version. Necessary files may be damaged. Reinstall the ID850NWC, and the device file. F6000: Current function does not exist. F6001: Illegal symbol name. F6002: Illegal condition. F6003: Illegal function name. User’s Manual U16525EJ1V0UM 299 APPENDIX E MESSAGES 300 F6004: Overflowed output buffer size. F6005: Illegal expression. F7000: Illegal mode. F7001: User program is running. F7002: User program has been stopped. F7003: Trace enabled. F7004: Trace memory is not set. F7005: Function return address does not exist, can not do step execution. F7801: End waiting state of step execution was canceled. F7802: End waiting state of step execution was canceled. F7f00: Aborted step execution. F7f02: Suspended step execution. F7f04: Can not execute non-mapped area. F7f05: This feature is not supported. F8000: Specified file was not found. F8001: Illegal line number. F8002: Current information is not set. F8003: Illegal address. F8004: This feature is not supported. F9002: Illegal value. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES F9005: This feature is not supported. Fa001: Illegal expression. Fa002: Start address is bigger than the end address. Fa003: Illegal source path. Fa004: Too long expression. Fa006: Illegal argument. Fa007: Illegal program number. Fa008: Source path is not set. Fa009: File not found. Fa00a: Can not open file. 1) The file is damaged or does not exist. Recreate the file. Fa00d: Not source file of load module. Fa00e: Illegal line number. Fa00f: Variable does not exist. Fa011: Can not access register. Fa012: Can not access memory. Fa014: It was going to open the binary file. Fa015: Can not get temporary path. 1) The disk is full. Delete or move unnecessary files and increase the available memory in the disk. Fa016: 1) Can not create temporary file. The disk is full. Delete or move unnecessary files and increase the available memory in the disk. Fa017: Can not remove temporary file. User’s Manual U16525EJ1V0UM 301 APPENDIX E MESSAGES Fa020: This feature is not supported. Fa021: Symbol assigned to register cannot be specified. Fb000: Illegal command line. Fb001: Program information does not exist in specified load module file. Fb002: File not found. Fb003: Function not found. Fb004: Selected load module different from kind(Chip) was loaded. Fb005: Symbol not found. 1) The address could not be found. Specify a location holding address information. Fb008: Illegal expression. Fb00a: Illegal symbol in load module file. Fb00b: Current program does not exist. Fb00c: Current file does not exist. Fb012: Too large line number. Fb01b: Too long load module file name. Fb01d: Address not found. Fb01f: Can not find structure member. Fb020: Can not find value. Fb021: No debug information exists in load module file. 1) To create a load module with appended debug information, execute build in build mode of Debug Build. Fb022: 302 Illegal line number. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES Fb026: Too many array dimensions (> 4). Fb027: Found end of file. 1) The specified file may be damaged. Recreate the file. Fb028: This feature is not supported. Fb029: Illegal address. Fb02b: Can not stack trace with current PC value. Fb02c: Too many blocks for one function. Fb02d: Illegal argument. Fb02e: The file does not exist in the SOURCE PATH. 1) On stopping the program, the source that the ID850NWC tried to display could not be found. Check if the path connects to the source (using "Source Path (source path specification area)" in the Debugger Option dialog box), or check if the source is in the same directory as the out file. Refer to the Assemble window on which the error message is displayed, and check if the corresponding path connects. Fb02f: Information has been deleted because of optimization. Fb034: Return execution from present PC position cannot be performed. Fb037: Too Many Line-Numbers Information. Fb038: Compiler version mismatch. 1) Recreate the load module with the latest compiler. Fb040: 1) Specified file is not load module. This is not a linker output file. Source debug cannot be executed with the load module before output from the linker. Specify the load module output from the linker. Fb32e: Illegal port number. Fb32f: Illegal port name. Fb330: Illegal port position. User’s Manual U16525EJ1V0UM 303 APPENDIX E MESSAGES Fb331: Illegal increment number. Fb332: Port for memory bank is not set. Fb333: Illegal bank number. Fb334: Area for memory bank is not set. Fc001: Can not open file. 1) The file is damaged or does not exist. Recreate the file. Fc005: Illegal file type. Fc006: Kind(Chip) of load module is illegal. Fc007: Specified file is not load module. 1) This is not a linker output file. Source debug cannot be executed with the load module before output from the linker. Specify the load module output from the linker. Fc008: Specified load module file (ELF) is old version. Fc00a: No mapped address was accessed. Fc00b: Load module is not loaded. Fc00c: Illegal argument. Fc00d: User program is running. Fc00e: User program is being traced. Fc00f: Interrupted. Fc011: Illegal load module file format. Fc012: Check sum error. Fc013: Too wide address range to upload (> 1M byte). Fc014: Failed in writing file. 1) 304 The file is damaged or does not exist. Recreate the file. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES Fc015: Illegal program number. Fc016: Load information is full. Fc018: Specified file is not load module. 1) This is not a linker output file. Source debug cannot be executed with the load module before output from the linker. Specify the load module output from the linker. Fc019: Failed in writing memory. Fc01b: Programmable-IOR address not specified. 1) Necessary files may be damaged. Reinstall ID850NWC. Fc100: This feature is not supported. Fd004: Can not find Dynamic Link Library. Fe000: Illegal argument. Fe001: Illegal start address. Fe002: Illegal end address. Fe003: Too large size. Fe004: Can not open file. 1) The file is damaged or does not exist. Recreate the file. Fe005: 1) Failed in reading file. The file is damaged or does not exist. Recreate the file. Fe006: Reading of file went wrong. Fe007: Failed in writing file. 1) The file is damaged or does not exist. Recreate the file. Fe009: Illegal file format. Fe00a: Verification error. User’s Manual U16525EJ1V0UM 305 APPENDIX E MESSAGES Fe010: This feature is not supported. Ff000: Not enough memory. Ff001: [XXX] not found. Ff004: Missing parameter. Ff005: Illegal function name. Ff006: Illegal number. Ff007: Start address is bigger than end address. Ff008: Illegal symbol or expression. Ff009: [XXX] This file is illegal type. Ff100: Disk cannot write or full. Ff101: File not found. Ff102: File not Create. Ff103: Old project file version.I Ff104: Illegal project file format. Ff105: This file is a project file for [XXX].Please select a correct file. Ff201: Memory mapping error. Ff202: Verify error. 1) External memory could not be accessed, as it is not set. Change the register values necessary for accessing the external memory using the IOR window or Hook Procedure before download (Refer to "To change the value of a register required for access of an external memory"). 306 Ff301: The symbol being used on the event condition can't be evaluated. Ff306: This name is too long. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES Ff307: There is the same name in other kinds. Ff308: An address can't be omitted. Ff309: Illegal address mask. Ff30a: Illegal data mask. Ff30b: Illegal ext probe mask. Ff30c: Illegal ext probe data. Ff30d: Illegal pass count. Ff30e: Illegal register name. Ff310: Illegal delay count. Ff312: [XXX] is already there. Ff313: Event number already exist. Ff314: Event name is not set. Ff315: [XXX] is already there. Ff316: Max number of enabled [XXX] event is over. Please disable other enabled [YYY] event. Ff317: Max number of set event is over. Ff31e: Illegal start address. Ff31f: Illegal end address. Ff350: There is a phase which event are not in the middle. Ff351: The same event is contained in Link and Disable. Ff352: An event isn't specified. Ff400: Coverage mapping error. User’s Manual U16525EJ1V0UM 307 APPENDIX E MESSAGES Ff500: Illegal symbol. Ff501: Illegal value. Ff502: Illegal parameter. Ff503: Max number of symbol is over. Ff504: This variable cannot be set as a break. 1) Break cannot be set for the following variables. • Local variables, static variables • Array variables, member variables of structures/unions • Register/peripheral IOR • Variable expressions Ff603: Incorrect ID Code. Ff900: Illegal I/O port name. Ff901: Memory mapping error. 1) The specification of the address is illegal. The addresses that can be specified are in either the Target area or IOR area. Check in "Address: (I/O port address specification area)" in the Add I/O Port dialog box. Ff902: Illegal access size. Ff903: Illegal access type. Ff904: There is the same name. Ffa00: The [XXX] function of current program on PC position not found. 1) The symbol specified in main() label: in "Startup Routine (start-up symbol setting area)" in the Debugger Option dialog box could be found. Set a symbol of the main routine of the program. Default is _main. Ffc00: Help window cannot be started. Please install HTML Help environment with reference to a users manual. 308 User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES E. 1. 5 Warning message or question message A list of the messages that are output when warnings or questions are detected while the debugger is executing processing is shown below in numerical order. W0c22: Memory unready status was canceled. W1014: Data is not exist. W2005: I/O register of Read Protect attribute was specified. W200d: No initialize data for IOR. W4013: Access size is different from its mapped bus size. W401c: Software break can not be set on this area. W500b: Specified device file does not relocate IRAM. W7010: No source information exists. W7011: Unknown result of step execution. Wb01e: No debug information (not compiled in Debug Build mode). Wb036: Out of variable region. Wb042: Symbol module is not initialized. Wb335: Too long symbol name. Wc017: Symbol information is duplicated, please reset symbols. Wc01a: BSS area is assigned to non-mapped area. 1) When the program is executed, a non-map break may occur. Either allocate the BSS area to the internal RAM by using a CA link directive, or map the emulation memory or target memory to the BSS area using the Configuration dialog box of the ID850NWC. Wc01c: 1) Programmable IOR address mismatch. Necessary files may be damaged. Reinstall the ID850NWC. Wc01d: Selected load module different from kind(Chip) was loaded. User’s Manual U16525EJ1V0UM 309 APPENDIX E MESSAGES Wf002: Not found [XXX]. Search from the beginning? Wf003: Already exceed search region. Wf106: CPU in the Project File was Changed. You must exit the debugger for the new CPU. Do you exit the Debugger? Wf107: CPU in the Project File was Changed. Do you start the Debugger with this CPU? Wf108: Selected project file different [YYY] from chip [XXX] was opened. Does it open, although the chip cannot be changed? Wf109: Project Manager cannot be used with the debugger of this version. Please use PMplus. Wf200: No difference encountered. Wf203: When a program is running, while rewriting a memory, program execution stops for a moment. Do you wish to rewrite a memory? 310 Wf300: Would you like to save the changes made in [XXX]? Wf302: Delete: [XXX] Wf303: [XXX] is edited. Delete: [YYY]? Wf304: [XXX] is edited. Save: [YYY]? Wf305: [XXX] is already exist. Do you replace it? Wf311: Only one [XXX] can be enabled. Do you make this [YYY] to enable? Wf325: User program is running. Do you want to stop user program for a moment and set it? Wf326: User program is running. Do you want to stop user program for a moment and delete it? Wf401: Clear coverage? Wf600: Save project file? Wf601: When connecting the target system, please turn on the target system. User’s Manual U16525EJ1V0UM APPENDIX E MESSAGES 1) When a target is not connected, simply click the <OK> button. Wf602: Please change a MODE mask condition or connect the target system. Wf700: Do you want to download Load Module File? Wf905: [XXX] is already exist. Do you replace it? Wf906: Would you like to register the change made in [XXX]? Wfb00: User program is running. Do you want to stop user program? User’s Manual U16525EJ1V0UM 311 APPENDIX F KEY FUNCTION LIST APPENDIX F KEY FUNCTION LIST Debugging can be efficiently executed by using special function keys. Note that, in the following explanation, ordinary key representation (generic key representation) is used because the key representation differs depending on the type of keyboard. Table F-1 through Table F-8 list the functions of the respective keys. F.1 Function List of Special Function Keys Table F-1 Function List of Special Function Keys Key 312 Function BackSpace Deletes one character before the cursor and moves the cursor to the position of the deleted character. At this time, the character string following the cursor moves forward. Delete Deletes one character after the cursor and move the character string following the cursor forward. Deletes a various event condition selected in the Event Manager or each event dialog box. Deletes the data selected in the Watch window. Insert Alternately selects the insert mode and overwrite mode in the Source window and Assemble window. However, this key is invalid in the Memory, Register, and IOR windows, and only the overwrite mode can be used as an input mode. PrintScreen Loads the entire display screen to the clipboard as a bitmap image (function of Windows). Esc Closes the pull-down menu. Closes the modal dialog box. Restores the input data. Alt Moves the cursor to the menu bar. End Moves the cursor to the end of the line. Home Moves the cursor to the beginning of the line. PageUp Scrolls the screen one screen up. The cursor also moves up to the top of the screen. PageDown Scrolls the screen one screen down. The cursor also moves up to the top of the screen. Space Inserts one blank character. Tab Moves the cursor to the next item. Up arrow key Moves the cursor up. If the cursor is at the bottom of the screen, scrolls the screen up one line at a time. Down arrow key Moves the cursor down. If the cursor is at the top of the screen, scrolls the screen down one line at a time. Right arrow key Moves the cursor to the left. If the cursor is at the left most position on the screen, scrolls the screen one column to the right. User’s Manual U16525EJ1V0UM APPENDIX F KEY FUNCTION LIST Table F-1 Function List of Special Function Keys Key F.2 Function Left arrow key Moves the cursor to the right. If the cursor is at the right most position on the screen, scrolls the screen one column to the left. Enter Sets the input data. Presses the default push button. Function List of Function Keys Table F-2 Function List of Function Keys Key F.3 Function F1 Opens the Help window. F2 Forcibly stops program execution. Same function as [Run] -> [Stop] on the menu bar. F3 Resets the CPU. Same function as [Run] -> [CPU Reset] on the menu bar. F4 Resets the CPU and executes the program. Same function as [Run] -> [Restart] on the menu bar. F5 Executes the program. Same function as [Run] -> [Go] on the menu bar. F6 Executes the program to the cursor position in the Source or Assemble window. Same function as [Run] -> [Come Here] on the menu bar F7 The user program is real-time executed until execution returns. Same function as [Run] -> [Return Out] on the menu bar F8 Step execution. Same function as [Run] -> [Step In] on the menu bar. F9 Sets a breakpoint at cursor position in Source or Assemble window. Same function as [Run] -> [Break Point] on the menu bar. F10 Next step execution. Same function as [Run] -> [Next Over] on the menu bar. F11 Sets or deletes a software breakpoint. Same function as [Run] -> [Software Break Point] on the menu bar. Function List of Special Function Keys (Shift + key) Table F-3 Function List of Special Function Keys (Shift + key) Key Function End Expands the selection range to the end of the line. Home Expands the selection range to the beginning of the line. Left arrow key Expands the selection range one character to the left. Right arrow key Expands the selection range one character to the right. User’s Manual U16525EJ1V0UM 313 APPENDIX F KEY FUNCTION LIST F.4 Function List of Function Keys (Shift + key) Table F-4 Function List of Function Keys (Shift + key) Key F.5 Function F6 Executes the program from the cursor position in the Source or Assemble window. Same function as [Run] -> [Start From Here] on the menu bar. F9 Resets the CPU. Same function as [Run] -> [CPU Reset] on the menu bar. List of Special Function Keys (Ctrl + key) Table F-5 List of Special Function Keys (Ctrl + key) Key F.6 Function End Displays the last line. The cursor will also move to the last line. Home Displays the first line. The cursor will also move to the first line. Left arrow key Moves the cursor one word to the left. If the cursor at the left most position on the screen, scrolls the screen one column to the right. Right arrow key Moves the cursor one word to the right. If the cursor at the right most position on the screen, scrolls the screen one column to the left. Function List of Function Keys (Ctrl + key) Table F-6 Function List of Function Keys (Ctrl + key) Key F.7 Function F5 Ignores break points being set, and executes the program. Same function as [Run] -> [Ignore break points and Go] on the menu bar. F9 Sets the address at the cursor position in the Source window or Assemble window to the PC. Same function as [Run] -> [Change PC] on the menu bar. Function List of Control Keys (Ctrl + key) Table F-7 Key 314 Function List of Control Keys (Ctrl + key) Function A Selects all the events registered to the Event Manager. Same function as [View] -> [Select All Event] on the menu bar in the Event Manager. C Copies a selected character string and saves it to the clipboard buffer. User’s Manual U16525EJ1V0UM APPENDIX F KEY FUNCTION LIST Table F-7 Function List of Control Keys (Ctrl + key) Key F.8 Function D Disassembles and displays the results from the jump destination address specified by the data value selected in the current window.Opens the Assemble window. Same function as [Jump] -> [Assemble] on the menu bar. E Opens the source file displayed in the active Source window with the editor specified by the PM plus when the PM plus is running. Same function as [Edit] -> [Edit Source] on the menu bar. G Performs a search.Opens the search dialog box corresponding to the current window. Same function as [View] -> [Search...] on the menu bar. J Moves the display position. Opens the Source Move, Address Move, or Trace Move dialog box, depending on the current window. Same function as [View] -> [Move...] on the menu bar. M Displays the memory contents from the jump destination address specified by the data value selected in the current window. Opens the Memory window. Same function as [Jump] -> [Memory...] on the menu bar. O Loads a view file, source file, or text file. Opens the View File Load dialog box. The operation will differ depending on the extension of the file. view file: Displays the file in the corresponding window. Others: Displays the file in the Source window. Same function as [File] -> [Open...] on the menu bar. S Saves the data displayed in the current window to the view file. Same function as [View] -> [Save...] on the menu bar. U Displays the corresponding source text and source line, using the data value selected in the current window as the jump destination address. Opens the Source window. Same function as [Jump] -> [Source Text] on the menu bar. V Pastes the contents of the clipboard buffer to the text cursor position. W Temporarily displays the contents of the specified data. Opens the Quick Watch dialog box. Same function as [View] -> [Quick Watch...] on the menu bar. X Cuts a selected character string and saves it to the clipboard buffer. Same function as [Edit] -> [Cut...] on the menu bar. List of Special Function Keys (Ctrl + Shift + key) Table F-8 Key List of Special Function Keys (Ctrl + Shift + key) Function Left arrow key Expands the selection range one word to the left. Right arrow key Expands the selection range one word to the right. User’s Manual U16525EJ1V0UM 315 APPENDIX G INDEX APPENDIX G INDEX Symbols [Come Here] function 117 [run] menu 29 [Start from Here] function 117 … … Download dialog box drag & drop function … A About dialog box 220 active status 39 Add I/O Port dialog box 186 Add Watch dialog box 159 address 229 Address Move dialog box 104 ASCII display 134 assemble 230 Assemble Search dialog box 129 Assemble window 124 auto load 27, 74, 84 auto save 74, 82 E error messages at startup 284 event condition 33 Event dialog box 199 event display mark 112 event function 33 event link condition 33 Event Link dialog box 206 Event Manager 189 Exit Debugger dialog box 218 EXPANSION 268 expansion window 268 expressions 278 Extended Option dialog box 68 extwin 238 B balloon watch function 34, 113, 154 batch 231 Break dialog box 212 break function 31 breakpoint 232 breakpoint for read/write access 155 breakpoint setting/deletion function 111 Browse dialog box 99 build mode 24 F file 281 finish 239 flash memory 29, 64 Flow of debugging operations 37 font 73 Font dialog box 78 Format of file that can be downloaded format of specifiable file 95 function 282 C cache 234 callback procedure 225 Change Watch dialog box 163 character set 276 color of character on event mark 191 color of character on mark 191 command 17, 221 command line 222 command list 222 command reference 222 compulsion read 178 Configuration dialog box 62 Console window 221 contents saved to project file 80 current window 281 G -g option go 240 … … … … … … … … … … … … … … … … … … … … … … … … … … D data display format 152 dbgexit 236 Debugger Option dialog box 71 delimiter 281 device file 18 disable condition 209 display color of breakpoint 111 displaying event details 193 DMM function 136 download 237 … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … 316 … 91 … 119 … … … … … … … … … … 18 … H help 241 hook 242 hook procedure 226 host machine 18 … … … … I I/O port 178, 186 I/O protect area 28 ID code 18, 64 ie 243 in-circuit emulator 18 information files 36 input conventions 276 installation 19 IOR Select dialog box 183 IOR window 178 … … … … … … J jump 244 jump function … … … 39 K key function list User’s Manual U16525EJ1V0UM … … … … 312 … 91 APPENDIX G INDEX L Load module list dialog box 97 load/save function 35 Local Variable window 166 … … M Main window 44 map 245 mapping function 28 mapping unit 67 marks of event icon 191 mask 203 mdi 246 memory 247 Memory Compare dialog box 144 Memory Compare Result dialog box Memory Copy dialog box 142 Memory Fill dialog box 140 memory manipulation function 34 Memory Search dialog box 137 Memory window 132 menu bar 47 messages 283 mixed display 116 module 248 … … … … … … … … … … … … … … … O offset setting 93 online assembly 124 operating environment operating system 18 operators 278 … … … … 18 … P pass count 209 PM plus 24 point mark area 111, 125 program 281 program code 112, 114 program counter setting 117 program execution function 29 program register 174 programmable IOR 34 project file 29, 74, 218 Project File Load dialog box 83 Project File Save dialog box 80 … … … … … … … … … Q Quick Watch dialog box … … … … 156 R range of radixes 280 refresh 250 register 251 register manipulation function … … … … 146 … … … … … 216 … … … … … … … … … … … … … … … … … … … T tab size 75 terminology 281 toolbar 44 … … … U uninstalling 20 upload 256 Upload dialog box … … … 95 V verify check 70 version 257 view file 35 View File Load dialog box View File Save dialog box … … … … 88 … 85 W watch 258 watch function 34, 118 watch symbol setting 76 Watch window 150 where 259 window lists 41 window reference 41 wish 260 … … … 34 … … 176 S select mode 200, 204, 207, 210 selecting debugger 24 setting debugging environment 29 setting event condition in each area 208 setting files 36 show offset 76 software break 32 Software Break Manager 196 Source Move dialog box 101 source path 72 Source Search dialog box 121 Source window 109 specification of scope 160 specifying symbols 107 stack frame 170, 282 start-up symbol 75 static status 39 status bar 59 step 254 stop 255 storing program in ROM 18 structure 282 Symbol To Address dialog box 106 symbols 277 system register 174 … … N next 249 normal mode 200, 207 N-Wire Checker 261 … … … … … … … … … Register Select dialog box Register window 173 registering debugger 24 reset 216, 252 Reset Debugger dialog box run 253 … … User’s Manual U16525EJ1V0UM … … … … … 317