Symbios® SYM20810 PCI to SCSI Host Adapter User’s Guide Version 1.1 ® Order Number S14037 Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. 2. This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • • Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic. The correction of interferences caused by such unauthorized modification, substitution, or attachment will be the responsibility of the user. The LSI Logic Symbios SYM20810 is tested to comply with FCC standards for home or office use. This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. LSI Logic Corporation North American Headquarters Milpitas, CA 408.433.8000 ii This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation. LSI Logic products are not intended for use in life-support appliances, devices, or systems. Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited. Document DB15-000134-00, Second Edition (December 1999) This document describes Version 1.1 of LSI Logic Corporation’s SYM20810 PCI to SCSI Host Adapter and will remain the official reference source for all revisions/releases of this product until rescinded by an update. To receive product literature, visit us at http://www.lsilogic.com LSI Logic Corporation reserves the right to make changes to any products herein at any time without notice. LSI Logic does not assume any responsibility or liability arising out of the application or use of any product described herein, except as expressly agreed to in writing by LSI Logic; nor does the purchase or use of a product from LSI Logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Logic or third parties. Copyright © 1997–1999 by LSI Logic Corporation. All rights reserved. TRADEMARK ACKNOWLEDGMENT LSI Logic logo design and Symbios are registered trademarks and SDMS is a trademark of LSI Logic Corporation. SR iii iv Contents Preface Chapter 1 What is Covered in this Guide 1.1 Installation 1.2 Connecting Internal SCSI Devices 1.2.1 Completing the Installation 1.2.2 Connecting External SCSI Devices 1.2.3 SCSI Bus Termination 1.2.4 Setting SCSI IDs 1.3 Installing the Host Adapter Device Driver Software 1.3.1 DOS/Windows 1.3.2 Windows 95/Windows NT 1.3.3 OS/2 1.4 Troubleshooting 1-3 1-5 1-7 1-7 1-9 1-11 1-12 1-12 1-12 1-13 1-14 Customer Feedback Figures 1.1 1.2 1.3 1.4 1.5 SYM20810 Board Outline Inserting the Host Adapter Internal SCSI Devices Chained Together Multiple External Devices Chained Together SCSI Bus Termination Contents 1-2 1-4 1-6 1-8 1-10 v vi Contents Preface This book is the primary reference and User’s Guide for the LSI Logic Symbios SYM20810 PCI to SCSI Host Adapter. It contains a complete functional description for the SYM20810 and includes complete physical and electrical specifications for the SYM20810. Audience This document assumes that you have some familiarity with microprocessors and related support devices. The people who benefit from this book are: • Engineers and managers who are evaluating the processor for possible use in a system • Engineers who are designing the processor into a system Related Publications Symbios PCI SCSI Device Management System SDMS 4.0 User’s Guide, LSI Logic Corporation, Order Number S14007 Revision Record Revision Date Remarks 1.0 9/97 First official release. 1.1 12/99 Miscellaneous cosmetic/format changes from Symbios to LSI Logic. Preface vii viii Preface Chapter 1 What is Covered in this Guide This installation guide provides instructions and illustrations to help you install a Symbios SYM20810 PCI to SCSI host adapter. It covers the following topics: • Section 1.1, “Installation” • Section 1.2, “Connecting Internal SCSI Devices” • Section 1.3, “Installing the Host Adapter Device Driver Software” • Section 1.4, “Troubleshooting” The SYM20810 provides a low-cost SCSI solution for attaching SCSI devices (disk drives, scanners, CD-ROM drives, tape drives, removable media drives, etc.) to PCI computer systems with an ISA/EISA bracket type. Figure 1.1 shows the major components and connections of the SYM20810 host adapter. The Symbios SCSI Device Management System (SDMS™) software includes drivers and utilities for operating this host adapter in computers running DOS/Windows, Windows 95, Windows NT, and OS/2. Symbios SYM20810 PCI to SCSI Host Adapter 1-1 Figure 1.1 SYM20810 Board Outline Internal SCSI Interface J2 P1 External SCSI Interface J3 SYM2081x, J1 to PCI Mainboard 1-2 What is Covered in this Guide 1.1 Installation Step 1. Before you begin the installation, switch off the power to the computer and any peripheral devices and disconnect all power cords. Caution: Before handling the SYM20810 board, ground yourself using a ground strap attached to the computer metal frame. Static charges on your body can damage electronic components. Handle plug-in boards by the edge; do not touch board components or gold connector contacts. Step 2. Remove the cover on your computer to access the PCI slots. Refer to your computer documentation if necessary. Step 3. Locate an unused expansion slot for installing the PCI to SCSI host adapter. Refer to your computer documentation if necessary to locate the expansion slots. Step 4. Remove the blank bracket panel on the back of the computer that covers the slot you intend to use. Save the bracket screw. Step 5. Remove the SYM20810 host adapter board from the antistatic bag and insert the edge connector into the PCI slot, as pictured in Figure 1.2. Make sure the edge connector is properly aligned before pressing the board into place. Apply even pressure to both ends of the board while inserting it. Installation 1-3 Figure 1.2 Inserting the Host Adapter Bracket Screw 1-4 What is Covered in this Guide 1.2 Connecting Internal SCSI Devices Step 1. If you are connecting an internal SCSI device, plug the 50-pin connector cable on one end of the internal SCSI ribbon cable into the connector J2 (see Figure 1.3). The ribbon cable included in your SYM20810 host adapter kit is keyed to assure that it can be easily connected. Step 2. Plug the 50-pin connector on the other end of the ribbon cable into the SCSI connector on your internal SCSI device. Step 3. To attach more than one internal device, use a SCSI ribbon cable with the required number of 50-pin connectors attached along its length. Plug the cable connectors into the internal SCSI device connectors, as illustrated in Figure 1.3. Step 4. Terminate the SCSI bus as described in the Section 1.2.3, “SCSI Bus Termination,” page 1-9. Step 5. Make any required power connections to your internal SCSI device(s). Connecting Internal SCSI Devices 1-5 Figure 1.3 Internal SCSI Devices Chained Together J2 1-6 What is Covered in this Guide 1.2.1 Completing the Installation Step 1. The bracket around the end connector (J3) should fit where the blank bracket panel was removed. Secure the bracket with the bracket screw. Step 2. Replace the cover as described in your computer documentation. 1.2.2 Connecting External SCSI Devices Step 1. If you need to connect external SCSI devices to the SYM20810 host adapter, plug the 50-pin connector on one end of a shielded external SCSI cable into the host adapter SCSI connector J3. This connector is now bracketed to the back panel of your computer. Figure 1.4 shows how this connection is made. Step 2. Plug the 50-pin connector on the other end of the SCSI cable into the SCSI connector on the peripheral device. This connection is shown in Figure 1.4. Step 3. If you wish to connect more than one device to the host adapter, use shielded cables to chain them together as illustrated in Figure 1.4. Step 4. Terminate the SCSI bus as described in the section Section 1.2.3, “SCSI Bus Termination,” page 1-9. Connecting Internal SCSI Devices 1-7 Figure 1.4 1-8 Multiple External Devices Chained Together What is Covered in this Guide 1.2.3 SCSI Bus Termination All SCSI devices have a set of resistors called terminators to assure reliable operation of the SCSI bus. The first and last physical devices on the SCSI bus must have these terminators enabled; all other SCSI devices on the bus must have their terminators removed or disabled. Termination on the SYM20810 host adapter is automatically enabled when it is connected to the end of the bus. Refer to the SCSI device documentation for information on how to identify and change the terminator setting on each SCSI peripheral device. Connecting Internal SCSI Devices 1-9 Figure 1.5 SCSI Bus Termination Last Device on Chain Termination Enabled Host Adapter Termination Automatically Disabled Last Device on Chain Termination Enabled 1-10 What is Covered in this Guide Does Not End Chain Termination Disabled 1.2.4 Setting SCSI IDs Each device on the SCSI bus, including the host adapter, must have a unique SCSI ID from 0 through 7. Refer to your peripheral device documentation for instructions on how to determine and change the ID of each peripheral device. The SCSI ID on the SYM20810 is 7. Caution: The SYM20810 host adapter supports only Single-Ended (SE) SCSI devices. Differential SCSI devices may be damaged if you connect them to this host adapter. Refer to your SCSI device documentation to make sure you are connecting a SE device. Connecting Internal SCSI Devices 1-11 1.3 Installing the Host Adapter Device Driver Software The SYM20810 is supported by Symbios SDMS drivers for DOS/Windows 3.x, Windows 95, Windows NT, and OS/2. Consult the software documentation for complete installation instructions. The Symbios SDMS driver/utility software and documentation for your operating system can be downloaded from the LSI Logic web site (www.lsilogic.com). 1.3.1 DOS/Windows The Symbios SDMS driver for DOS runs under DOS 5.0 and above and all versions of Windows 3.x. Consult the software documentation (dos.txt) for specific installation instructions and descriptions of the DOS/Windows 3.x drivers and utilities. Symbios SDMS software also includes the following DOS/Windows utilities: • DOS Installation Utility • SCSI Low Level Format Utility • Verify Utility • SCSI Configuration Utility 1.3.2 Windows 95/Windows NT Windows 95 and Windows NT (versions 3.51 and newer) have embedded support for the SYM20810, so the driver is installed automatically during setup. To add the SYM20810 to an existing system, install the board according to the instructions in this guide, then restart the computer. The operating system will automatically launch the “Add New Hardware” wizard to install the driver. Follow these steps to make sure that the driver software has been properly installed: Step 1. From the Windows 95 Start menu, select Settings, then Control Panel. Step 2. From the Control Panel window, click the System icon. The System Properties menu displays. Step 3. Select the Device Manager. Step 4. Click on the SCSI Controllers icon. 1-12 What is Covered in this Guide Step 5. The name of the driver for the SYM20810 is “Symbios 8100ASP, 2081x PCI SCSI Adapter; 53C810A Device.” If this driver is not listed, follow the instructions in the Symbios SDMS Windows 95 or Windows NT driver documentation. This documentation can be found on the LSI Logic web site at www.lsilogic.com. Step 6. If there are no red X’s or yellow question mark icons next to the listing for the SYM20810, the driver is loaded and ready to use. Please keep in mind that Windows NT only displays the driver information, not every controller found by the driver. For information on how to change the Symbios driver in your system or to add a driver to a Windows 95 or Windows NT system that is set up with a different SCSI driver, refer to the LSI Logic Symbios PCI SCSI Device Management System SDMS 4.0 User’s Guide or the software documentation that accompanies the driver on your diskette or on the LSI Logic web site. The file names are 95.txt for Windows 95 and 8xxnt.txt for Windows NT. 1.3.3 OS/2 The Symbios SYM8XX.ADD device driver complies with the IBM OS/2 Adapter Device Driver specification, and works with third party applications that comply with the same specification. For complete installation instructions, refer to the OS2.txt file supplied with your Symbios OS/2 SCSI driver software. The latest version of this driver and the text file may also be found on the LSI Logic web site at www.lsilogic.com. Installing the Host Adapter Device Driver Software 1-13 1.4 Troubleshooting During installation, no SCSI devices are found: • Check the cable connections and the host bus adapter installation. • Ensure that all devices are powered on and terminated correctly. • Check that no devices have duplicate SCSI IDs. • Make sure INT A is assigned for the PCI slot(s) where your SCSI host adapter(s) are installed. • Make sure the SCSI device driver is installed properly. The computer hangs or locks up when booting and the SCSI devices attached are not seen by the computer system: • Make sure that all the SCSI devices are configured at different ID numbers (the boot drive should have the lowest ID). • Make sure both ends, but only the ends, of the SCSI bus are terminated. • (DOS, OS/2) Make sure the device driver is listed in CONFIG.SYS (and loaded when booting). The device driver does not see one of the SCSI devices: 1-14 • Reboot the computer. • Make sure the SCSI devices have different ID numbers (the boot drive should have the lowest ID). • Make sure both ends, but only the ends, of the SCSI bus are terminated. • Check the cable and power connections. What is Covered in this Guide Customer Feedback We would appreciate your feedback on this document. Please copy the following page, add your comments, and fax it to us at the number shown. If appropriate, please also fax copies of any marked-up pages from this document. Important: Please include your name, phone number, fax number, and company address so that we may contact you directly for clarification or additional information. Thank you for your help in improving the quality of our documents. Reader’s Comments Fax your comments to: LSI Logic Corporation Technical Publications M/S E-198 Fax: 408.433.4333 Please tell us how you rate this document: Symbios® SYM20810 PCI to SCSI Host Adapter User’s Guide. Place a check mark in the appropriate blank for each category. Excellent Good Average Completeness of information Clarity of information Ease of finding information Technical content Usefulness of examples and illustrations Overall manual Fair Poor ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ What could we do to improve this document? If you found errors in this document, please specify the error and page number. If appropriate, please fax a marked-up copy of the page(s). Please complete the information below so that we may contact you directly for clarification or additional information. Name Telephone Title Department Company Name Street City, State, Zip Customer Feedback Date Fax Mail Stop U.S. Distributors by State A. E. Avnet Electronics http://www.hh.avnet.com B. M. Bell Microproducts, Inc. (for HAB’s) http://www.bellmicro.com I. E. Insight Electronics http://www.insight-electronics.com W. E. Wyle Electronics http://www.wyle.com Alabama Daphne I. E. Tel: 334.626.6190 Huntsville A. E. Tel: 256.837.8700 I. E. Tel: 256.830.1222 W. E. Tel: 800.964.9953 Alaska A. E. Tel: 800.332.8638 Arkansas W. E. Tel: 972.235.9953 Arizona Phoenix A. E. Tel: 480.736.7000 B. M. Tel: 602.267.9551 W. E. Tel: 800.528.4040 Tempe I. E. Tel: 480.829.1800 Tucson A. E. Tel: 520.742.0515 California Agoura Hills B. M. Tel: 818.865.0266 Irvine A. E. Tel: 949.789.4100 B. M. Tel: 949.470.2900 I. E. Tel: 949.727.3291 W. E. Tel: 800.626.9953 Los Angeles A. E. Tel: 818.594.0404 W. E. Tel: 800.288.9953 Sacramento A. E. Tel: 916.632.4500 W. E. Tel: 800.627.9953 San Diego A. E. Tel: 858.385.7500 B. M. Tel: 858.597.3010 I. E. Tel: 800.677.6011 W. E. Tel: 800.829.9953 San Jose A. E. Tel: 408.435.3500 B. M. Tel: 408.436.0881 I. E. Tel: 408.952.7000 Santa Clara W. E. Tel: 800.866.9953 Woodland Hills A. E. Tel: 818.594.0404 Westlake Village I. E. Tel: 818.707.2101 Colorado Denver A. E. Tel: 303.790.1662 B. M. Tel: 303.846.3065 W. E. Tel: 800.933.9953 Englewood I. E. Tel: 303.649.1800 Connecticut Cheshire A. E. Tel: 203.271.5700 I. E. Tel: 203.272.5843 Wallingford W. E. Tel: 800.605.9953 Delaware North/South A. E. Tel: 800.526.4812 Tel: 800.638.5988 B. M. Tel: 302.328.8968 W. E. Tel: 856.439.9110 Florida Altamonte Springs B. M. Tel: 407.682.1199 I. E. Tel: 407.834.6310 Boca Raton I. E. Tel: 561.997.2540 Clearwater I. E. Tel: 727.524.8850 Fort Lauderdale A. E. Tel: 954.484.5482 W. E. Tel: 800.568.9953 Miami B. M. Tel: 305.477.6406 Orlando A. E. Tel: 407.657.3300 W. E. Tel: 407.740.7450 Tampa W. E. Tel: 800.395.9953 St. Petersburg A. E. Tel: 727.507.5000 Georgia Atlanta A. E. Tel: 770.623.4400 B. M. Tel: 770.980.4922 W. E. Tel: 800.876.9953 Duluth I. E. Tel: 678.584.0812 Hawaii A. E. Tel: 800.851.2282 Idaho A. E. W. E. Tel: 801.365.3800 Tel: 801.974.9953 Illinois North/South A. E. Tel: 847.797.7300 Tel: 314.291.5350 Chicago B. M. Tel: 847.413.8530 W. E. Tel: 800.853.9953 Schaumburg I. E. Tel: 847.885.9700 Indiana Fort Wayne I. E. Tel: 219.436.4250 W. E. Tel: 888.358.9953 Indianapolis A. E. Tel: 317.575.3500 Iowa W. E. Tel: 612.853.2280 Cedar Rapids A. E. Tel: 319.393.0033 Kansas W. E. Tel: 303.457.9953 Kansas City A. E. Tel: 913.663.7900 Lenexa I. E. Tel: 913.492.0408 Kentucky W. E. Tel: 937.436.9953 Central/Northern/ Western A. E. Tel: 800.984.9503 Tel: 800.767.0329 Tel: 800.829.0146 Louisiana W. E. Tel: 713.854.9953 North/South A. E. Tel: 800.231.0253 Tel: 800.231.5575 Maine A. E. W. E. Tel: 800.272.9255 Tel: 781.271.9953 Maryland Baltimore A. E. Tel: 410.720.3400 W. E. Tel: 800.863.9953 Columbia B. M. Tel: 800.673.7461 I. E. Tel: 410.381.3131 Massachusetts Boston A. E. Tel: 978.532.9808 W. E. Tel: 800.444.9953 Burlingtonr I. E. Tel: 781.270.9400 Marlborough B. M. Tel: 508.480.9099 Woburn B. M. Tel: 781.933.9010 Michigan Brighton I. E. Tel: 810.229.7710 Detroit A. E. Tel: 734.416.5800 W. E. Tel: 888.318.9953 Minnesota Champlin B. M. Tel: 800.557.2566 Eden Prairie B. M. Tel: 800.255.1469 Minneapolis A. E. Tel: 612.346.3000 W. E. Tel: 800.860.9953 St. Louis Park I. E. Tel: 612.525.9999 Mississippi A. E. Tel: 800.633.2918 W. E. Tel: 256.830.1119 Missouri W. E. Tel: 630.620.0969 St. Louis A. E. Tel: 314.291.5350 I. E. Tel: 314.872.2182 Montana A. E. Tel: 800.526.1741 W. E. Tel: 801.974.9953 Nebraska A. E. Tel: 800.332.4375 W. E. Tel: 303.457.9953 Nevada Las Vegas A. E. Tel: 800.528.8471 W. E. Tel: 702.765.7117 New Hampshire A. E. Tel: 800.272.9255 W. E. Tel: 781.271.9953 New Jersey North/South A. E. Tel: 201.515.1641 Tel: 609.222.6400 Mt. Laurel I. E. Tel: 609.222.9566 Pine Brook W. E. Tel: 800.862.9953 Parsippany I. E. Tel: 973.299.4425 Wayne W. E. Tel: 973.237.9010 New Mexico W. E. Tel: 480.804.7000 Albuquerque A. E. Tel: 505.293.5119 U.S. Distributors by State (Continued) New York Hauppauge I. E. Tel: 516.761.0960 Long Island A. E. Tel: 516.434.7400 W. E. Tel: 800.861.9953 Rochester A. E. Tel: 716.475.9130 I. E. Tel: 716.242.7790 W. E. Tel: 800.319.9953 Smithtown B. M. Tel: 800.543.2008 Syracuse A. E. Tel: 315.449.4927 North Carolina Raleigh A. E. Tel: 919.859.9159 I. E. Tel: 919.873.9922 W. E. Tel: 800.560.9953 North Dakota A. E. Tel: 800.829.0116 W. E. Tel: 612.853.2280 Ohio Cleveland A. E. Tel: 216.498.1100 W. E. Tel: 800.763.9953 Dayton A. E. Tel: 614.888.3313 I. E. Tel: 937.253.7501 W. E. Tel: 800.575.9953 Strongsville B. M. Tel: 440.238.0404 Valley View I. E. Tel: 216.520.4333 Oklahoma W. E. Tel: 972.235.9953 Tulsa A. E. Tel: 918.459.6000 I. E. Tel: 918.665.4664 Oregon Beavertonr B. M. Tel: 503.524.0787 I. E. Tel: 503.644.3300 Portland A. E. Tel: 503.526.6200 W. E. Tel: 800.879.9953 Pennsylvania Mercer I. E. Tel: 412.662.2707 Pittsburgh A. E. Tel: 412.281.4150 W. E. Tel: 440.248.9996 Philadelphia A. E. Tel: 800.526.4812 B. M. Tel: 215.741.4080 W. E. Tel: 800.871.9953 Rhode Island A. E. 800.272.9255 W. E. Tel: 781.271.9953 South Carolina A. E. Tel: 919.872.0712 W. E. Tel: 919.469.1502 South Dakota A. E. Tel: 800.829.0116 W. E. Tel: 612.853.2280 Tennessee W. E. Tel: 256.830.1119 East/West A. E. Tel: 800.241.8182 Tel: 800.633.2918 Texas Austin A. E. Tel: 512.219.3700 B. M. Tel: 512.258.0725 I. E. Tel: 512.719.3090 W. E. Tel: 800.365.9953 Dallas A. E. Tel: 214.553.4300 B. M. Tel: 972.783.4191 W. E. Tel: 800.955.9953 El Paso A. E. Tel: 800.526.9238 Houston A. E. Tel: 713.781.6100 B. M. Tel: 713.917.0663 W. E. Tel: 800.888.9953 Richardson I. E. Tel: 972.783.0800 Rio Grande Valley A. E. Tel: 210.412.2047 Stafford I. E. Tel: 281.277.8200 Utah Centerville B. M. Tel: 801.295.3900 Murray I. E. Tel: 801.288.9001 Salt Lake City A. E. Tel: 801.365.3800 W. E. Tel: 800.477.9953 Vermont A. E. Tel: 800.272.9255 W. E. Tel: 716.334.5970 Virginia A. E. Tel: 800.638.5988 W. E. Tel: 301.604.8488 Washington Kirkland I. E. Tel: 425.820.8100 Seattle A. E. Tel: 425.882.7000 W. E. Tel: 800.248.9953 West Virginia A. E. Tel: 800.638.5988 Wisconsin Milwaukee A. E. Tel: 414.513.1500 W. E. Tel: 800.867.9953 Wauwatosa I. E. Tel: 414.258.5338 Wyoming A. E. Tel: 800.332.9326 W. E. Tel: 801.974.9953 Direct Sales Representatives by State (Component and HAB) E. A. E. L. GRP I. S. ION R. A. SGY Earle Associates Electrodyne - UT Group 2000 Infinity Sales, Inc. ION Associates, Inc. Rathsburg Associates, Inc. Synergy Associates, Inc. Arizona Tempe E. A. Tel: 480.921.3305 California Calabasas I. S. Tel: 818.880.6480 Irvine I. S. Tel: 714.833.0300 San Diego E. A. Tel: 619.278.5441 Illinois Elmhurst R. A. Tel: 630.516.8400 Indiana Cicero R. A. Tel: 317.984.8608 Ligonier R. A. Tel: 219.894.3184 Plainfield R. A. Tel: 317.838.0360 Massachusetts Burlington SGY Tel: 781.238.0870 Michigan Byron Center R. A. Tel: 616.554.1460 Good Rich R. A. Tel: 810.636.6060 Novi R. A. Tel: 810.615.4000 North Carolina Cary GRP Tel: 919.481.1530 Ohio Columbus R. A. Tel: 614.457.2242 Dayton R. A. Tel: 513.291.4001 Independence R. A. Tel: 216.447.8825 Pennsylvania Somerset R. A. Tel: 814.445.6976 Texas Austin ION Tel: 512.794.9006 Arlington ION Tel: 817.695.8000 Houston ION Tel: 281.376.2000 Utah Salt Lake City E. L. Tel: 801.264.8050 Wisconsin Muskego R. A. Tel: 414.679.8250 Saukville R. A. Tel: 414.268.1152 Sales Offices and Design Resource Centers LSI Logic Corporation Corporate Headquarters Tel: 408.433.8000 Fax: 408.433.8989 NORTH AMERICA California Costa Mesa - Mint Technology Tel: 949.752.6468 Fax: 949.752.6868 Irvine ♦ Tel: 949.809.4600 Fax: 949.809.4444 Pleasanton Design Center Tel: 925.730.8800 Fax: 925.730.8700 San Diego Tel: 858.467.6981 Fax: 858.496.0548 Silicon Valley ♦ Tel: 408.433.8000 Fax: 408.954.3353 Wireless Design Center Tel: 858.350.5560 Fax: 858.350.0171 Colorado Boulder ♦ Tel: 303.447.3800 Fax: 303.541.0641 Colorado Springs Tel: 719.533.7000 Fax: 719.533.7020 Fort Collins Tel: 970.223.5100 Fax: 970.206.5549 Florida Boca Raton Tel: 561.989.3236 Fax: 561.989.3237 Georgia Alpharetta Tel: 770.753.6146 Fax: 770.753.6147 Illinois Oakbrook Terrace Tel: 630.954.2234 Fax: 630.954.2235 Kentucky Bowling Green Tel: 270.793.0010 Fax: 270.793.0040 Maryland Bethesda Tel: 301.897.5800 Fax: 301.897.8389 Massachusetts Waltham ♦ Tel: 781.890.0180 Fax: 781.890.6158 Burlington - Mint Technology Tel: 781.685.3800 Fax: 781.685.3801 Minnesota Minneapolis ♦ Tel: 612.921.8300 Fax: 612.921.8399 New Jersey Red Bank Tel: 732.933.2656 Fax: 732.933.2643 Cherry Hill - Mint Technology Tel: 609.489.5530 Fax: 609.489.5531 New York Fairport Tel: 716.218.0020 Fax: 716.218.9010 North Carolina Raleigh Tel: 919.785.4520 Fax: 919.783.8909 Oregon Beaverton Tel: 503.645.0589 Fax: 503.645.6612 Texas Austin Tel: 512.388.7294 Fax: 512.388.4171 Plano ♦ Tel: 972.244.5000 Fax: 972.244.5001 Houston Tel: 281.379.7800 Fax: 281.379.7818 Canada Ontario Ottawa ♦ Tel: 613.592.1263 Fax: 613.592.3253 INTERNATIONAL France Paris LSI Logic S.A. Immeuble Europa ♦ Tel: 33.1.34.63.13.13 Fax: 33.1.34.63.13.19 Germany Munich LSI Logic GmbH ♦ Tel: 49.89.4.58.33.0 Fax: 49.89.4.58.33.108 Stuttgart Tel: 49.711.13.96.90 Fax: 49.711.86.61.428 Italy Milano LSI Logic S.P.A. ♦ Tel: 39.039.687371 Fax: 39.039.6057867 Japan Tokyo LSI Logic K.K. ♦ Tel: 81.3.5463.7821 Fax: 81.3.5463.7820 Osaka ♦ Tel: 81.6.947.5281 Fax: 81.6.947.5287 Korea Seoul LSI Logic Corporation of Korea Ltd Tel: 82.2.528.3400 Fax: 82.2.528.2250 The Netherlands Eindhoven LSI Logic Europe Ltd Tel: 31.40.265.3580 Fax: 31.40.296.2109 Singapore Singapore LSI Logic Pte Ltd Tel: 65.334.9061 Fax: 65.334.4749 Tel: 65.835.5040 Fax: 65.732.5047 Sweden Stockholm LSI Logic AB ♦ Tel: 46.8.444.15.00 Fax: 46.8.750.66.47 Taiwan Taipei LSI Logic Asia, Inc. Taiwan Branch Tel: 886.2.2718.7828 Fax: 886.2.2718.8869 United Kingdom Bracknell LSI Logic Europe Ltd ♦ Tel: 44.1344.426544 Fax: 44.1344.481039 ♦ Sales Offices with Design Resource Centers International Distributors Australia New South Wales Reptechnic Pty Ltd ♦ Tel: 612.9953.9844 Fax: 612.9953.9683 Belgium Acal nv/sa Tel: 32.2.7205983 Fax: 32.2.7251014 China Beijing LSI Logic International Services Inc. Tel: 86.10.6804.2534 Fax: 86.10.6804.2521 France Rungis Cedex Azzurri Technology France Tel: 33.1.41806310 Fax: 33.1.41730340 Germany Haar EBV Elektronik Tel: 49.89.4600980 Fax: 49.89.46009840 Munich Avnet Emg GmbH Tel: 49.89.45110102 Fax: 49.89.42.27.75 Wuennenberg-Haaren Peacock AG Tel: 49.2957.79.1692 Fax: 49.2957.79.9341 Hong Kong Hong Kong AVT Industrial Ltd Tel: 852.2428.0008 Fax: 852.2401.2105 EastEle Tel: 852.2798.8860 Fax: 852.2305.0640 India Bangalore Spike Technologies India Private Ltd ♦ Tel: 91.80.664.5530 Fax: 91.80.664.9748 Israel Tel Aviv Eastronics Ltd Tel: 972.3.6458777 Fax: 972.3.6458666 Japan Tokyo Global Electronics Corporation Tel: 81.3.3260.1411 Fax: 81.3.3260.7100 Technical Center Tel: 81.471.43.8200 Yokohama-City Macnica Corporation Tel: 81.45.939.6140 Fax: 81.45.939.6141 The Netherlands Eindhoven Acal Nederland b.v. Tel: 31.40.2.502602 Fax: 31.40.2.510255 Switzerland Brugg LSI Logic Sulzer AG Tel: 41.32.3743232 Fax: 41.32.3743233 Taiwan Taipei Avnet-Mercuries Corporation, Ltd Tel: 886.2.2516.7303 Fax: 886.2.2505.7391 Lumax International Corporation, Ltd Tel: 886.2.2788.3656 Fax: 886.2.2788.3568 Prospect Technology Corporation, Ltd Tel: 886.2.2721.9533 Fax: 886.2.2773.3756 Serial Semiconductor Corporation, Ltd Tel: 886.2.2579.5858 Fax: 886.2.2570.3123 United Kingdom Maidenhead Azzurri Technology Ltd Tel: 44.1628.826826 Fax: 44.1628.829730 Swindon EBV Elektronik Tel: 44.1793.849933 Fax: 44.1793.859555 ♦ Sales Offices with Design Resource Centers