NTV SERIES 3kVDC Isolated 1W Dual Output SM DC-DC Converters SELECTION GUIDE Nominal Input Voltage Output Voltage Output Current (V) (V) (mA) (mA) (%) (pF) kHrs OrderCode5 Input Current at Rated Load Efficiency Isolation Capacitance MTTF1 NTV0505M 5 5 ±100 282 71 33 1697 NTV0509M 5 9 ±55 260 77 38 682 NTV0512M 5 12 ±42 253 79 44 343 NTV0515M 5 15 ±33 250 80 43 188 559 NTV1205M 12 5 ±100 114 73 50 NTV1209M 12 9 ±55 105 79 72 375 NTV1212M 12 12 ±42 104 80 89 243 ■ 3kVDC Isolation (1 Minute) NTV1215M 12 15 ±33 101 82 100 154 ■ Wide Temperature Performance at Full 1 Watt Load, -40°C to 85°C i When operated without additional external load capacitance, the output voltage of the devices is guaranteed to be within 95% of its steady state value within 100ms after the input voltage has reached 95% of its steady state value, irrespective of the rise time of the input voltage. ii When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up. FEATURES ■ Lead Frame Technology ■ CECC00802 Reflow (280°C) ■ Dual Isolated Output ■ Efficiency to 82% ■ Power Density 1.5W/cm 3 ■ 5V & 12V Input ■ 5V, 9V, 12V and 15V Output ■ Footprint Over Pins 1.64cm2 ■ UL 94V-0 Package Material ■ No Heatsink Required ■ Internal SMD Construction ■ Toroidal Magnetics ■ Plastic Encapsulated ■ MTTF up to 2.1 Million Hours ■ Custom Solutions Available ■ Multi Layer Ceramic Capacitors ■ Lead Free Compatibility ■ Tape and Reel Option INPUT CHARACTERISTICS Parameter Conditions MIN TYP MAX Voltage Range Continuous operation, 5V input types 4.5 Continuous operation, 12V input types 10.8 5 12 41 5.5 V 13.2 47 mA p-p TYP MAX Units 1.0 W 1.2 12 8.0 8.5 7.0 75 65 60 60 %/% Reflected Ripple Current OUTPUT CHARACTERISTICS Parameter Conditions Rated Power2 Voltage Set Point Accuracy Line regulation TA = -40°C to 85°C MIN See tolerance envelope High VIN to low V IN 10% load to rated load, 5V output types Load Regulation 3 10% load to rated load, 9V output types 10% load to rated load, 12V output types 10% load to rated load, 15V output types BW=DC to 20MHz, 5V output types Ripple and Noise BW=DC to 20MHz, 9V output types BW=DC to 20MHz, 12V output types BW=DC to 20MHz, 15V output types 1.0 10 6.5 6.0 6.0 50 40 40 40 DESCRIPTION The NTV series of 3kV isolation miniature surface mounted DC-DC Converters employ leadframe technology and transfer moulding techniques to bring all of the benefits of IC style packaging to hybrid circuitr y. The devices are fully compatible with CECC00802 to 280°C which allows them to be placed and reflowed with IC’s, thus reducing time and cost in production. The coplanarity of the pin positions is based upon IEC 191-6:1990. The devices are suitable for all applications where high volume production is envisaged. www.dc-dc.com Units ABSOLUTE MAXIMUM RATINGS Short circuit duration 4 Internal power dissipation Lead temperature 1.5mm from case for 10 seconds Input Voltage VIN , NTV05 types Input voltage V IN , NTV12 types 1 2 3 4 5 1second 550mW 300°C 7V 15V Calculated using MIL-HDBK-217F with nominal input voltage at full load. See derating curve. 12V input types have typically 3% less load regulation change. Supply voltage must be discontinued at the end of the short circuit duration. If components are required in tape and reel format suffix order code with -R, e.g. NTV0505M-R. All specifications typical at TA =25°C, nominal input voltage and rated output current unless otherwise specified. % mV p-p NTV SERIES 3kVDC Isolated 1W Dual Output SM DC-DC Converters ISOLATION CHARACTERISTICS Parameter Conditions Isolation Test Voltage Resistance For 1 Minute Viso=1000VDC MIN TYP MAX Units 3000 10 VDC GΩ GENERAL CHARACTERISTICS Parameter Conditions Switching Frequency 5V input types 12V input types MIN TYP MAX Units 115 115 kHz TEMPERATURE CHARACTERISTICS Parameter Conditions MIN Specification Storage Case Temperature above ambient All output types -40 -55 5V output types All other output types Free air convection Cooling TYP MAX Units 85 125 °C °C 46 35 °C PERFORMANCE CHARACTERISTICS tolerance envelope 2.0 +10% +5% +2.5% V nominal temperature derating graph 1.5 -2.5% 0.5 10 50 Output Load Current (%) 85°C 1.0 -7.5% Safe Operating Area 0 100 -40 0 50 100 Ambient Temperature (°C) 150 MECHANICAL DIMENSIONS 15.24 12.70 22 20 18 DETAIL A 14 12 NTV0505M 11.20 7.70 10.40 P XYYWW 1 3 5 2.54 9 0.5 REFERENCE PLANE 1.50 1.20 11 ±5.00° 10 PINS 0.65 0.2 M S 0.55 P 2.10 6.60 (6.35) (5.95) 5.85 2.79MAX DETAIL A S SEATING PLANE 0.25 0.10 Weight: 1.53g 1.875 MAX 0.1 S For tape and reeling packaging details refer to datasheet NDCAN002.1 C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use. © C&D Technologies (NCL) Limited 2000 NDC NTV.2 No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited. Instructions for use are available from www.dc-dc.com PIN 1 GND 3 VIN 5 NA 9 0V 11 -V 12 NA 14 +V 18 NA 20 NA 22 NA 0.30 0.20 All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch. C&D Technologies (NCL) Ltd Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax:+44 (0)1908 617545 email: [email protected] www: http://www.dc-dc.com C&D Technologies (NCL), Inc. 8917 Glenwood Avenue, Raleigh NC 27612, USA Tel: +1 (919) 571-9405 Fax: +1 (919) 571-9262 email: [email protected]