ETC V300A5C400AN3

45
300Vin / 5Vout / 400Watts
DC-DC Converter Module
Model Number V300A5C400A*
Features
•
•
•
•
•
•
•
•
•
•
•
DC input range: 180 - 375V
Input surge withstand: 400V for 100ms
DC output: 5V
Programmable output: 10 to 110%
Regulation: ±0.2% no load to full load
Efficiency: 83.5%
Maximum operating temperature:
100°C at full load
Power density: 79W/cubic inch
Height above board: 0.43 in. (10,9 mm)
Parallelable, with N+M fault tolerance
Low noise ZCS/ZVS architecture
Shown actual size:
4.6 x 2.2 x 0.5 in
117 x 56 x 12,7 mm
Typical Applications: off-line systems,
distributed power and electric vehicles
Product Overview
This DC-DC converter module uses
2nd Generation power processing, control
and packaging technologies to provide the
performance, flexibility and cost effectiveness
expected of a mature power component.
For example, a plated-cavity core transformer
couples widely separated primary and
secondary windings, resulting in low in-toout parasitic capacitance and noise.
High frequency ZCS/ZVS switching,
advanced power semiconductor packaging
and thermal management provide high
power density with low temperature
gradients. Extensive use of silicon
integration results in 1/3 the part count
of a 1st Generation converter.
Absolute Maximum Ratings
Parameter
Rating
Unit
+In to –In voltage
-0.5 to +375.0
Vdc
+In to –In voltage
400
Vdc
PC to –In voltage
-0.5 to +7.0
Vdc
PR to –In voltage
-0.5 to +7.0
Vdc
+Out to –Out voltage
-0.5 to +7.0
Vdc
+Sense to –Out voltage
-0.5 to +7.0
Vdc
–Sense to –Out voltage
1.0
Vdc
-0.5 to +1.5
Vdc
Isolation voltage (in to out)
3000
Vrms
Isolation voltage (in to base)
1550
Vrms
SC to –Out voltage
Notes
<100ms
* Part Numbering
Isolation voltage (out to base)
500
Vrms
V 300 A 12 C 500 A
Storage temperature (C–Grade)
-40 to +125
°C
See part numbering chart on this
page for other product grades.
Operating temperature (C–Grade)
-20 to +100
°C
Baseplate
Pin soldering temperature
500 (260)
°F (°C)
<5 sec; wave solder
Pin soldering temperature
750 (390)
°F (°C)
<7 sec; hand solder
5 (0.57)
in-lbs (N-m)
Input Voltage
24 = 24Vin
48 = 48Vin
300 = 300Vin
375 = 375Vin
A = Maxi
B = Mini
C = Micro
Output
Voltage
Output
Power
Pin
Style
Product Grade Temperatures (°C)
Grade Storage
Operating
C = - 40 to +125 - 20 to +100
T = - 40 to +125 - 40 to +100
H = - 55 to +125 - 40 to +100
M = - 65 to +125 - 55 to +100
Baseplate
For pin styles see page 6. Slotted baseplate
(style 1) requires no designator. For
threaded baseplate add a “2” to the end of
the part number. For thru-hole, add a “3”.
See page 7 for dimensions.
Mounting torque
6 each, # 4-40 or M3
Thermal Resistance and Capacity
Parameter
Min
Typ
Max
Unit
Baseplate to sink; flat, greased surface
0.08
°C/Watt
Baseplate to sink; thermal pad (P/N 20263)
0.07
°C/Watt
Baseplate to ambient
4.9
°C/Watt
Baseplate to ambient; 1000 LFM
1.1
°C/Watt
Thermal capacity
165
Watt-sec/°C
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715
Data Sheet: V300A5C400A DC-DC Converter Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 1 of 8
ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
MODULE OPERATING SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Operating input voltage
180
300
375
Vdc
400
Vdc
<100ms
Input surge withstand
Notes
Output voltage setpoint
4.95
5.00
5.05
Vdc
Nominal input; full load; 25°C
Output OVP setpoint
6.03
6.25
6.47
Vdc
25°C; recycle input voltage to restart ( 1 minute off )
400
Watts
Output power
Efficiency
82.5
83.5
%
At 100°C baseplate temperature
Nominal input; 75% of full load; 25°C
MODULE INPUT SPECIFICATIONS
Parameter
Min
Undervoltage turn-on
Undervoltage turn-off
147.4
Typ
Max
Unit
174.6
178.2
Vdc
152.8
Vdc
Overvoltage turn-off/on
Vdc
Dissipation, standby
Notes
Not included
6.2
9.3
Watts
No load
Typ
Max
Unit
Notes
Line regulation
±0.02
±0.20
%
Low line to high line; full load
Load regulation
±0.06
±0.20
%
No load to full load; nominal input
Temperature regulation
±0.002
±0.005
% / °C
Over operating temperature range
70
88
mV
81.6
92.0
112.0
Amps
Output voltage 95% of nominal
56
92
112
Amps
Output voltage <250mV
±2
±5
%
10 to 100% of full load
%
Of nominal output voltage. For trimming below
90% of nominal, a minimum load of 10% of
maximum rated power may be required.
MODULE OUTPUT SPECIFICATIONS
Parameter
Min
Ripple and noise, p-p
Current limit
Short circuit current
Power sharing accuracy
Programming range
10
110
Nominal input, full load; 25°C; 20MHz bandwidth
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
MODULE MECHANICAL SPECIFICATIONS
Baseplate
Pin style
Slotted (Style 1)
Slotted baseplate (style 1) requires no designator.
For threaded baseplate add a "2" to the end of the
part number. For thru-hole add a "3".
Short (Style 1)
For long pin configuration add “L” to the end of the
part number. See page 7 for pin dimensions.
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715
Data Sheet: V300A5C400A DC-DC Converter Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 2 of 8
ELECTRICAL CHARACTERISTICS, continued
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
PRIMARY SIDE (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
5.50
1.5
5.75
2.1
6.00
3.0
Vdc
mA
PC current = 1.0 mA
PC voltage = 5.5V
PC module disable
2.3
2.6
2.9
Vdc
Must be able to sink ≥4 mA. See Fig. 1
4
7
ms
0.5
Vavg
UV, OV, OT, module fault. See Figs. 2 and 4
6.1
Volts
PR load >30 ohms, < 30 pF
PC module enable delay
PC module alarm
PR emitter amplitude
5.7
5.9
PR emitter current
150
PR receiver impedance
375
500
625
ohms
25°C
PR receiver threshold
2.4
2.5
2.6
Volts
Minimum pulse width: 20ns
12
modules
Without PR buffer amplifier
mA
PR drive capability
SECONDARY SIDE (SC = Secondary Control)
SC bandgap voltage
1.21
1.23
1.25
Vdc
SC resistance
990
1000
1010
ohms
SC capacitance
SC module alarm
Referenced to –Sense
0.033
µF
0
Vdc
With open trim; referenced to –Sense. See Fig. 6
Max
Unit
Notes
0.5
Vdc
0.25V per leg (senses must be closed)
MODULE GENERAL SPECIFICATIONS
Parameter
Min
Typ
Remote sense (total drop)
Isolation voltage (in to out)
3000
Vrms
Complies with reinforced insulation requirements
Isolation voltage (in to base)
1550
Vrms
Complies with basic insulation requirements
Isolation voltage (out to base)
500
Vrms
Complies with operational insulation requirements
Isolation resistance (in to out)
10
Weight
Temperature limiting
Agency approvals
7.3 (210)
100
megohms
8 (227)
115
°C
UL, CSA, TÜV, BABT, CE, VDE
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715
ounces (grams)
See Figs. 2 and 4
UL1950, CSA950, EN60950, VDE0805, BS7002,
IEC 60950. With a fuse in series with the +Input
Data Sheet: V300A5C400A DC-DC Converter Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 3 of 8
CONTROL FUNCTIONS - PC PIN
Module Enable/Disable
Module Alarm
The module may be disabled by pulling PC below 2.3V with
respect to the –Input. This may be done with an open collector
transistor, relay, or optocoupler. Multiple converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes. See Figure 1.
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will shut
down and PC will go low. PC will periodically go high and the
module will check to see if the fault (as an example,
overtemperature) has cleared. If the fault has not been cleared,
PC will go low again and the cycle will restart. The SC pin will
go low in the event of a fault and return to its normal state after
the fault has been cleared. See Figures 2 and 4.
Primary Auxiliary Supply
At 5.7V, PC can source up to 1.5mA. In the example shown in
Figure 3, PC powers a module enabled LED.
+In
+In
SW1
PC
Input Undervoltage
Input Overvoltage
Overtemperature
Module Faults
Auto
Restart
PC
2-20ms typ.
f (VIN)
Disable
SW2
SW3
1K
SC
–S
5.7 Vdc
(0-3mA)
–In
+S
50Ω
SW1, 2, & 3
shown in
"Fault" position
PR
PR
+Out
1.23
Vdc
–In
6K
–Out
Disable = PC <2.3V
Figure 1—Module enable/disable.
Figure 2—PC/SC module alarm logic.
+In
Fault
PC
"Module
Enabled"
PC
40µs typ.
5.7V
4kΩ
PR
SC
–In
Figure 3—LED on-state indicator.
Optocoupler
1.23V
2-20ms typ.
Figure 4—PC/SC module alarm timing.
+In
+Out
PC
+S
SC
4kΩ
PR
–S
–In
–Out
Figure 5—Isolated on-state indicator.
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715
Alarm
1.00V
Figure 6—Secondary side on-state indicator.
Data Sheet: V300A5C400A DC-DC Converter Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 4 of 8
CONTROL FUNCTIONS - SC PIN
Output Voltage Programming
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figures 7 and 8.
+Out
+Out
+S
Error
Amp
SC
1kΩ
0.033µF
–S
+S
RD
Trim Down
Load
Error
Amp
SC
1kΩ
0.033µF
–Out
RU
Trim Up
Load
–S
–Out
1.23V
1.23V
RD (ohms) =
1,000 Vout
Vnom - Vout
RU (ohms) =
1,000 (Vout-1.23) Vnom
1.23 (Vout-Vnom)
–1,000
Figure 7—Output voltage trim down circuit.
Figure 8—Output voltage trim up circuit.
Trim Down
Trim Up
1. This converter is not a constant power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
1. The converter is rated for a maximum delivered power. To ensure
that maximum rated power is not exceeded, reduce maximum
output current by the same percentage increase in output voltage.
2. The trim down resistor must be connected to the –Sense pin.
2. The trim up resistor must be connected to the +Sense pin.
3. Do not trim the converter above maximum trim range
(typically +10%) or the output over voltage
protection circuitry may be activated.
Trim values calculated automatically:
Resistor trim calculators are available on Vicor’s
web site at URL: www.vicorpower.com/
tools.html or by requesting a copy of
Vicor’s Applications Manual on a CD ROM.
Resistor values can be calculated for fixed
trim up, fixed trim down and for variable
trim up or down cases for both 1st and
2nd Generation DC-DC converters.
In addition to trimming information, the
web site and the applications manual on
CD ROM also include design tips,
applications circuits, EMC suggestions,
thermal design guidelines and PDF data
sheets for all available Vicor products.
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715
Data Sheet: V300A5C400A DC-DC Converter Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 5 of 8
CONTROL FUNCTIONS - PR PIN
Parallel Operation
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy and phased array capability. Modules of
the same input voltage, output voltage, and power level will
current share if all PR pins are suitably interfaced.
Compatible interface architectures include the following:
DC coupled single-wire interface. All PR pins are directly
connected to one another. This interface supports current
sharing but is not fault tolerant. Minus In pins must be tied to
the same electric potential. See Figure 9.
AC coupled single-wire interface. All PR pins are connected
to a single communication bus through 0.001µF (500V)
capacitors. This interface supports current sharing and is fault
tolerant except for the communication bus. See Figure 10.
+In
+In
PC
PC
0.001µF
Module 1
Module 1
PR
PR
–In
–In
+In
+In
PC
PR
Module 2
(up to 12)
PC
0.001µF
PR
–In
–In
Ground plane
Ground plane
Figure 10—AC coupled single-wire interface.
Figure 9—DC coupled single-wire interface.
+Out
+S
SC
–S
Module 1
• The +Out and –Out power buses should be
designed to minimize and balance parasitic
impedance from each module output to the load.
+S
–S
–Out
+S
+Out
+S
SC
–S
Module 2
+S
Load
+Out
• The +Sense pins should be tied to the same
point on the +Out power bus; the –Sense pins
should be tied to the same point on the –Out
power bus.
+S
SC
–S
–Out
–S
• At the discretion of the power system designer,
a subset of all modules within an array may be
configured as slaves by shorting SC to –S.
–S
–Out
+Out
+S
SC
–S
Module N+1
–Out
Module 2
(up to 12)
• OR’ing diodes may be inserted in series with
the +Out pins of each module to provide
module output fault tolerance.
Figure 11—N+1 module array output connections.
+Sense from
other modules
in the array
Figure 12—OR’ing diodes connections.
PIN STYLES *
Designator
Description
Notes
(None)
Short solder
Requires in-board, mounting
L
Long solder
On-board mounting for 0.65" boards
S
Short ModuMate
SurfMate or in-board socket mounting
N
Long ModuMate
On-board socket mounting
* Pin style designator follows the “A” after the output power and precedes the baseplate designator.
Ex. V375A24C600AN — Long ModuMate Pins
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715
Data Sheet: V300A5C400A DC-DC Converter Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 6 of 8
MECHANICAL DRAWINGS
MODULE OUTLINE
0.50 ±0.02
12,7 ±0,5
Converter Pins
No. Function Label
1
+In
0.300 ±0.015
7,62 ±0,38
+
PC
3
Parallel
PR
4
–In
–
5
–Out
–
6
–Sense
–S
7
Secondary
Control
SC
8
+Sense
+S
9
+Out
+
0.01
1
0.300 ±0.015
7,62 ±0,38
2
PINS: TIN/LEAD
HOT SOLDER DIP
9
3
6
or
4-40 UNC-2B (6X)
FULL R (6X)
3.60
91,4
0.13
(6X)
3,3
5
0.43
10,9
0.180
DIA,(2X)
4,57
0.080
DIA,(7X)
2,03
0.700
17,78
1.000
25,40
1.400
35,56
Threaded (Style 2)
1.80
45,7
4.60
116,8
4.200
106,68
7
0.10
2,5
0.10
X 45°
2,5
CHAMFER
ALUMINUM
BASEPLATE
8
2.00
50,8
0.38
(2X)
9,6
4
0.400
10,16
Slotted (Style 1)
0.50
12,7
4-40 UNC-2B
0.12* 0.20**
Thru (4X)***
3,1 5,08
(Style 2 and 3 only)
1.74
44,2
0.23
(REF)
5,8
(ALL MARKINGS THIS SURFACE)
2
Primary
Control
2.20
55,9
R
0.06
(3X)
1,5
Use a
4-40 Screw (6x)
Torque to:
5 in-lbs
0.57 N-m
2.20
55,9
(REF)
0.54
(9X) Pin Style 1
13,7
(Short Pin)
0.62
(9X) Pin Style 2
15,7
(Long Pin)
or
Thru Hole (Style 3)
* Style 1 baseplate only
** Style 2 & 3 baseplates
*** Reserved for Vicor accessories
#30 Drill Thru (6X)
(0.1285)
ALL MARKINGS
THIS SURFACE
PCB MOUNTING SPECIFICATIONS
PCB THICKNESS
R
0.062 ±0.010
1,57 ±0,25
PLATED
THRU HOLE
DIA
1.790
45,47
0.06
(4X)
1,5
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
PIN STYLE 1
PIN STYLE 2
(7X)
0.094 ±0.003
2,39 ±0,08
0.094 ±0.003
2,39 ±0,08
(2X)
0.194 ±0.003
4,93 ±0,08
0.194 ±0.003
4,93 ±0,08
0.178
4,52
1
2
3
4
ALUMINUM
BASEPLATE
PINS: TIN/LEAD
HOT SOLDER DIPPED
4.200*
106,68
3.844
97,64
9
8
7
6
5
Unless otherwise specified,
dimensions are in inches
mm
0.400*
10,16
0.195
4,95
0.700*
17,78
1.000*
25,40
1.400*
35,56
0.43
10,9
0.53
13,5
0.XX
Tol.
Angles
±0.01
±0,25
* DENOTES
±0.003
TOL =
±0,08
Vicor Corporation Tel: 800-735-6200 Fax: 978-475-6715
Decimals
0.XXX
±1°
±0.005
±0,127
Data Sheet: V300A5C400A DC-DC Converter Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 7 of 8
Vicor’s comprehensive line of power solutions includes modular, high
density DC-DC converters and accessory components, configurable power
supplies, and custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is
assumed by Vicor for its use. No license is granted by implication or otherwise under any patent or patent
rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems,
wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and
Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
45
Component Solutions
for Your Power System
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
Email
Vicor Express: [email protected]
Technical Support: [email protected]
Data Sheet: V300A5C400A DC-DC Converter
Date: 11-01 Rev. 4
Set your site on VICOR at www.vicorpower.com
Page 8 of 8