ETC UGN3144*

Data Sheet
27621.6A
3141 THRU
3144
SENSITIVE HALL-EFFECT SWITCHES
FOR HIGH-TEMPERATURE OPERATION
X
These Hall-effect switches are monolithic integrated circuits with
tighter magnetic specifications, designed to operate continuously over
extended temperatures to +150°C, and are more stable with both
temperature and supply voltage changes. The unipolar switching
characteristic makes these devices ideal for use with a simple bar or rod
magnet. The four basic devices (3141, 3142, 3143, and 3144) are
identical except for magnetic switch points.
CC
2
3
OUTPUT
SUPPLY
1
GROUND
V
Dwg. PH-003A
Each device includes a voltage regulator for operation with supply
voltages of 4.5 to 24 volts, reverse battery protection diode, quadratic
Hall-voltage generator, temperature compensation circuitry, smallsignal amplifier, Schmitt trigger, and an open-collector output to sink
up to 25 mA. With suitable output pull up, they can be used with
bipolar or CMOS logic circuits. The A3141– and A3142– are improved replacements for the UGN/UGS3140–; the A3144– is the
improved replacement for the UGN/UGS3120–.
The first character of the part number suffix determines the device
operating temperature range. Suffix ‘E–’ is for the automotive and
industrial temperature range of -40°C to +85°C. Suffix ‘L–’ is for the
automotive and military temperature range of -40°C to +150°C. Three
package styles provide a magnetically optimized package for most
applications. Suffix ‘–LT’ is a miniature SOT-89/TO-243AA transistor package for surface-mount applications; suffix ‘–U’ is a three-lead
plastic mini-SIP, while suffix ‘–UA’ is a three-lead ultra-mini-SIP.
Pinning is shown viewed from branded side.
FEATURES and BENEFITS
ABSOLUTE MAXIMUM RATINGS
at TA = +25°C
Supply Voltage, VCC ............................ 28 V
Reverse Battery Voltage, VRCC ........... -35 V
Magnetic Flux Density, B .......... Unlimited
Output OFF Voltage, VOUT .................. 28 V
Reverse Output Voltage, VOUT ........... -0.5 V
Continuous Output Current, IOUT ...... 25 mA
■
■
■
■
■
■
■
■
Superior Temp. Stability for Automotive or Industrial Applications
4.5 V to 24 V Operation … Needs Only An Unregulated Supply
Open-Collector 25 mA Output … Compatible with Digital Logic
Reverse Battery Protection
Activate with Small, Commercially Available Permanent Magnets
Solid-State Reliability
Small Size
Resistant to Physical Stress
Operating Temperature Range, TA
Suffix ‘E–’ .................. -40°C to +85°C
Suffix ‘L–’ ................ -40°C to +150°C
Storage Temperature Range,
TS .............................. -65°C to +170°C
Always order by complete part number, e.g., A3141ELT .
3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
FUNCTIONAL BLOCK DIAGRAM
1
VCC
REG.
X
3
OUTPUT
2
GROUND
Dwg. FH-005-2
ELECTRICAL CHARACTERISTICS at VCC = 8 V over operating temperature range.
Limits
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Supply Voltage
VCC
Operating
4.5
—
24
V
VOUT(SAT)
IOUT = 20 mA, B > BOP
—
175
400
mV
Output Leakage Current
IOFF
VOUT = 24 V, B < BRP
—
<1.0
10
µA
Supply Current
ICC
B < BRP (Output OFF)
—
4.4
9.0
mA
Output Rise Time
tr
RL = 820 Ω, CL = 20 pF
—
0.04
2.0
µs
Output Fall Time
tf
RL = 820 Ω, CL = 20 pF
—
0.18
2.0
µs
Output Saturation Voltage
MAGNETIC CHARACTERISTICS in gauss over operating supply voltage range.
Part Numbers*
A3141–
Characteristic
BOP at TA = 25°C
over operating temp. range
BRP at TA = 25°C
over operating temp. range
Bhys at TA = 25°C
over operating temp. range
A3142–
Min.
Typ.
Max.
Min. Typ.
50
100
160
130
30
100
175
10
45
10
A3143–
A3144–
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
180
230
220
280
340
70
—
350
115
180
245
205
280
355
35
—
450
130
75
125
175
165
225
285
50
—
330
45
145
60
125
190
150
225
300
25
—
430
20
55
80
30
55
80
30
55
80
20
55
—
20
55
80
30
55
80
30
55
80
20
55
—
NOTES: Typical values are at TA = +25°C and VCC = 8 V.
BOP = operate point (output turns ON); BRP = release point (output turns OFF); Bhys = hysteresis (BOP - BRP).
*Complete part number includes a suffix to identify operating temperature range (E- or L-) and package type ( -LT, -U, or -UA).
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
Copyright © 1993, 1999, Allegro MicroSystems, Inc.
3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
TYPICAL OPERATING CHARACTERISTICS
A3142– SWITCH POINTS
OUTPUT SATURATION VOLTAGE
300
400
I OUT = 20 mA
V
=8V
V CC = 4.5–24 V
CC
SATURATION VOLTAGE IN mV
SWITCH POINT IN GAUSS
300
OPERATE POINT
200
RELEASE POINT
100
0
-25
25
50
100
75
125
100
0
-50
0
-50
200
150
-25
0
25
50
75
100
125
150
AMBIENT TEMPERATURE IN °C
AMBIENT TEMPERATURE IN °C
Dwg. GH-044
Dwg. GH-040-1
SUPPLY CURRENT
SUPPLY CURRENT
10
7.0
VCC = 8 V
B ≥ B OP
SUPPLY CURRENT IN mA
SUPPLY CURRENT IN mA
8.0
B ≥ B OP
6.0
B ≤ B RP
4.0
6.0
5.0
T A = +25°C
2.0
B ≤ B RP
4.0
0
0
5
10
15
20
25
SUPPLY VOLTAGE IN VOLTS
-50
-25
0
25
50
75
100
125
150
AMBIENT TEMPERATURE IN °C
Dwg. GH-041-1
* Complete part number includes a suffix denoting operating temperature range (E- or L-) and package type ( -LT, -U, or -UA).
Dwg. GH-039-1
3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
SENSOR LOCATIONS
TYPICAL OPERATING CHARACTERISTICS (cont.)
(±0.005” [0.13 mm] die placement)
CHANGE IN OPERATE POINT
Suffix “LT”
20
ACTIVE AREA DEPTH
0.030"
0.76 mm
NOM
0.043"
1.09 mm
A
1
2
3
Dwg. MH-008-2C
Suffix “U”
ACTIVE AREA DEPTH
0.016"
0.41 mm
NOM
CHANGE IN OPERATE POINT IN GAUSS
0.089"
2.26 mm
15
T A = +25°C
10
5.0
0
-5.0
0.091"
2.31 mm
0
5
10
15
Dwg. GH-042-1
OPERATION
A
1
2
3
Dwg. MH-002-2B
Suffix “UA”
ACTIVE AREA DEPTH
0.019"
0.48 mm
NOM
The output of these devices (pin 3) switches low when the magnetic field
at the Hall sensor exceeds the operate point threshold (BOP). At this point, the
output voltage is VOUT(SAT). When the magnetic field is reduced to below the
release point threshold (BRP), the device output goes high. The difference in
the magnetic operate and release points is called the hysteresis (Bhys) of the
device. This built-in hysteresis allows clean switching of the output even in
the presence of external mechanical vibration and electrical noise.
0.082"
2.07 mm
0.055"
1.39 mm
A
BRANDED
SURFACE
25
SUPPLY VOLTAGE IN VOLTS
0.070"
1.78 mm
BRANDED
SURFACE
20
1
2
3
Dwg. MH-011-10
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
PACKAGE DESIGNATOR ‘LT’
(SOT-89/TO-243AA)
Dimensions in Inches
(for reference only)
0.173
0.181
0.064
0.072
0.155
0.167
1
2
0.055
0.063
3
0.090
0.102
0.014
0.017
0.084
0.090
0.014
0.019
0.017
0.022
0.035
0.047
0.059
BSC
0.118
BSC
Dwg. MA-009-3 in
Dimensions in Millimeters
(controlling dimensions)
4.40
4.60
1.62
1.83
3.94
4.25
1
2
1.40
1.60
3
2.29
2.60
0.35
0.44
2.13
2.29
0.36
0.48
0.89
1.20
0.44
0.56
1.50
BSC
3.00
BSC
Dwg. MA-009-3 mm
NOTES: 1. Tolerances on package height and width represent allowable mold offsets. Dimensions given are
measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
PACKAGE DESIGNATOR ‘U’
Dimensions in Inches
(controlling dimensions)
Dimensions in Millimeters
(for reference only)
4.65
4.52
0.183
0.178
1.60
1.50
0.063
0.059
4.60
4.47
0.181
0.176
45°
45°
0.086
1
2
0.018
3
2.18
1
2
0.46
3
MAX
MAX
0.600
0.560
15.24
14.23
0.015
0.38
0.41
0.016
SEE NOTE
SEE NOTE
1.27
0.050
2.54
0.100
Dwg. MH-003D in
Dwg. MH-003D mm
Devices in the ‘U’ package are
NOT RECOMMENDED FOR NEW DESIGN
NOTES: 1. Tolerances on package height and width represent allowable mold offsets. Dimensions given are measured
at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
4. Recommended minimum PWB hole diameter to clear transition area is 0.035" (0.89 mm).
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
PACKAGE DESIGNATOR ‘UA’
Dimensions in Inches
(controlling dimensions)
Dimensions in Millimeters
(for reference only)
4.17
4.04
0.164
0.159
0.062
0.058
45°
1.57
1.47
45°
3.10
2.97
0.122
0.117
45°
45°
0.085
1
2
3
0.031
2.16
1
2
3
0.79
MAX
MAX
0.640
0.600
16.26
15.24
0.015
SEE NOTE
SEE NOTE
0.016
0.41
1.27
0.050
BSC
0.38
Dwg. MH-014D in
BSC
Dwg. MH-014D mm
NOTES: 1. Tolerances on package height and width represent allowable mold offsets. Dimensions given are
measured at the widest point (parting line).
2. Exact body and lead configuration at vendor’s option within limits shown.
3. Height does not include mold gate flash.
Allegro MicroSystems, Inc. reserves the right to make, from time to time,
such departures from the detail specifications as may be required to permit
improvements in the design of its products.
The information included herein is believed to be accurate and reliable.
However, Allegro MicroSystems, Inc. assumes no responsibility for its use;
nor for any infringements of patents or other rights of third parties which
may result from its use.
3141 THRU 3144
SENSITIVE
HALL-EFFECT SWITCHES
FOR HIGH-TEMP. OPERATION
HALL-EFFECT SENSORS SELECTION GUIDE
Partial Part
Number
Avail. Oper.
Characteristics at TA = +25°C
Temp.
BOP(max) BRP(min) Bhys(typ)
Features
HALL-EFFECT UNIPOLAR SWITCHES in order of BOP and Bhys
3240
3210
3361
3362
3161
3141
3235
E/L
E
E
E
E
E/L
S
5140
3142
3143
3144
3122
3123
3121
3150
E
E/L
E/L
E/L
E/L
E/L
E/L
J
+50
±70
+120
+120
+160
+160
+175
-25
+200
+230
+340
+350
+400
+440
+450
+40 to +850
+5.0
±5.0
+50
+50
+30
+10
+25
-175
+50
+75
+165
+50
+140
+180
+125
–
10
7.7
5.0*
5.0*
20
55
15*
15*
55
55
55
55
105
105
105
20
Notes
chopper stabilized
micropower, chopper stabilized
2-wire, chopper stabilized
2-wire, chopper stabilized
2-wire
1
output 1
output 2
300 mA output
2
2
1, 3
programmable, chopper stabilized
1
†
HALL-EFFECT LATCHES & BIPOLAR SWITCHES in order of BOP and Bhys
3260
E/L
+30
-30
20
bipolar, chopper stabilized
3280
E/L
+40
-40
45
chopper stabilized
3134
E/L
+50
-50
27
bipolar switch
3133
K/L/S
+75
-75
52
bipolar switch
3281
E/L
+90
-90
100
chopper stabilized
3132
K/L/S
+95
-95
52
bipolar switch
3187
E/L
+150
-150
100*
3177
S
+150
-150
200
3625
S
+150
-150
200
900 mA outputs
1, 3, 5
3626
S
+150
-150
200
400 mA outputs
1, 3, 5
3195
E/L
+160
-160
220
1, 4
3197
L
+160
-160
230
1
3175
S
+170
-170
200
3188
E/L
+180
-180
200*
3283
E/L
+180
-180
300
chopper stabilized
3189
E/L
+230
-230
100*
3275
S
+250
-250
100*
5
3185
E/L
+270
-270
340*
Operating Temperature Ranges:
S = -20°C to +85°C, E = -40°C to +85°C, J = -40°C to +115°C, K = -40°C to +125°C, L = -40°C to +150°C
Notes 1. Protected.
2. Output 1 switches on south pole, output 2 switches on north pole for 2-phase, bifilar-wound, unipolar-driven brushless dc
motor control.
3. Power driver output.
4. Active pull down.
5. Complementary outputs for 2-phase bifilar-wound, unipolar-driven brushless dc motor control.
* Minimum.
† Latches will not switch on removal of magnetic field; bipolar switches may switch on removal of field but require field reversal for
reliable operation over operating temperature range.
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000