ETC AD6435

a
ADSL Chipset
AD6435
FEATURES
Component in Analog Devices DMT ADSL Chipset—
AD20msp910
Designed to ANSI/ETSI T1.413
Suitable for CO or Residence (ATU-R and ATU-C)
Performs All Digital Interface Tasks:
Elastic Store; Byte-Stuffing/Robbing
Synchronization and EOC and AOC Insertion/Removal
CRC Generation/Detection
Scrambler and Descrambler
Forward Error Correction/Detection
Interleave/Deinterleave
Absolute Maximum Data Rate: 12 Mbps Simplex/
4 Mbps Duplex
Simple Interface: Synchronous Simplex and Duplex
Streams
128-Lead TQFP
Operating Temperature Range: –408C to +858C
3.3 V Operation, 400 mW
GENERAL DESCRIPTION
The AD6435 is part of the Analog Devices ADSL chipset, the
AD20msp910. It accompanies the AD6436 (DMT accelerator),
AD6437 (single-chip analog front end) and ADTSP-2183 (control and DSP). Object code is also supplied. Offering a flexible, standard-based approach (designed to ANSI T1.413,
Category 1) with low total bill of materials and high performance, the chipset offers a straightforward approach to realizing
an ADSL modem.
The AD6435 interfaces the ADSL modem to the external system, at either CO or RT modem. It implements all the bitstuffing/robbing and elastic store operations, and all digital
processing (block and forward error correction, scrambling,
interleaving, etc.). The AD6435 has four simple synchronous
connections, duplex in and out, simplex in (only used at
ATU-C) and simplex out (used at ATU-R), which may be
treated as the AS0 Simplex and LS0 duplex stream of the standard. These have “clean” clock and data, and may operate
asynchronously of one another, or of the modem itself.
FUNCTIONAL BLOCK DIAGRAM
BYPASS PORT
DUPLEX_TX
TRANSMIT
DUPLEX_RX
SIMPLEX_TX
(ATU-C)
ELASTIC STORE,
FRAMING,
BYTE–STUFF/ROB
TO AD6436/AD6439
DIGITAL LOGIC,
FEC, CRC
INTERLEAVING
RECEIVE
CONTROL
FROM AD6436/AD6439
SIMPLEX_RX
(ATU-R)
AD6435
TO ADTSP2183 INTERLEAVE RAM
REV. 0
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
World Wide Web Site: http://www.analog.com
Fax: 781/326-8703
© Analog Devices, Inc., 1997
AD6435–SPECIFICATIONS
Parameter
Units
Comments
ABSOLUTE MAXIMUM SIMPLEX DATA RATE
12.288 Mbps
Absolute Maximum.
May not be achieved under realistic conditions.
Actual performance will depend on copper loop.
ABSOLUTE MAXIMUM DUPLEX DATA RATE
4.096 Mbps
Absolute Maximum.
May not be achieved under realistic conditions.
Actual performance will depend on copper loop.
INTERNAL PLL FOR CLOCK REGENERATION
176.64 MHz
Resolution is 172.5 Hz/Bit 0.076 Unit Intervals.
VDD SUPPLY VOLTAGE
3.3 V ± 10%
POWER DISSIPATION
400 mW
TA OPERATING TEMPERATURE
–40°C to +85°C
Typical
Specifications are subject to change without notice.
ABSOLUTE MAXIMUM RATINGS *
ELECTRICAL SPECIFICATIONS
Parameter
Typ Value
Comments*
VOH
VOL
VIH
VIL
IIH
IIL
VDD–0.4 V dc
0.4 V dc
2.0 V dc
1.0 V dc
± 500 nA
± 500 nA
At IOH = –0.5 mA
At IOL = +1.0 mA
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +4.6 V
Input Voltage . . . . . . . . . . . . . . . . . . . . –0.5 V to VDD + 0.5 V
Output Voltage Swing . . . . . . . . . . . . . –0.5 V to VDD + 0.5 V
Operating Temperature Range (Ambient) . . . –40°C to +85°C
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
Lead Temperature (5 sec) TQFP . . . . . . . . . . . . . . . . +280°C
VIN = VDD = 3.6 V
VIN = 0 V, VDD = 3.6 V
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
*VDD = 3.3 V dc ± 10%.
ORDERING GUIDE
Model
Temperature Range
Package Description
Package Option
AD6435
–40°C to +85°C
128-Lead Plastic Thin Quad Flatpack
ST-128
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD6435 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
–2–
WARNING!
ESD SENSITIVE DEVICE
REV. 0
AD6435
1
D0
2
TEST4
104 A0
103 A1
105 VDD12
106 GND12
108 NRD
107 NCS
109 NWR
111 D15
110 NRESET
112 D14
114 D12
102 A2
PIN 1
IDENTIFIER
101
A3
3
100
A4
SIMPLX_TX
4
99
A5
SIMPLX_CLKI
5
98
A6
SIMPLX_CLKO
6
97
VDD1
7
96
A7
VDD11
GND1
8
95
GND11
SIMPLX_RX
9
94
DSP_CLK
DUPLX_TX
10
93
A8
DUPLX_CLKI
11
92
A9
DUPLX_CLKO
12
91
A10
DUPLX_RX
13
90
A11
RX_BUF
14
89
A12
VDD2
15
88
VDD10
GND2
16
87
GND10
RFS
17
86
A13
RX_FR
18
85
RX_FRM
RX_SPFR
19
84
RX_SDATA
RX_SPFRI
20
83
RX_DREQ
TX_BUF
21
82
RX_BS
TFS
22
81
TX_RX_SCLK
GND3
23
80
GND9
VDD3
24
79
VDD9
TX_FR
25
78
TX_FRM
TX_SPFR
26
77
TX_SDATA
MCLK_OUT
27
76
TX_BS
TEST0
28
75
TX_DREQ
TEST1
29
74
MCLK
RT_NCO
30
73
NM_OE
GND4
31
72
GND8
VDD4
32
71
VDD8
NC
33
70
NM_WE
NC
34
69
M_A14
PLL_GND
35
68
M_A13
PLL_VDD
36
67
M_A12
PLL_RBIAS
37
66
M_A11
NC
38
65
M_A10
AD6435
DTIR
128 TQFP
–3–
M_A9 64
M_A8 63
VDD7 62
GND7 61
M_A7 60
M_A6 59
M_A5 58
M_A3 56
M_A4 57
M_A2 55
M_A1 54
M_A0 53
VDD6 51
GND6 52
M_D0 50
M_D1 49
M_D2 48
M_D3 47
M_D4 46
M_D6 44
M_D5 45
M_D7 43
VDD5 41
GND5 42
TEST3 40
TEST2 39
TOP VIEW
(Not to Scale)
NC = NO CONNECT
REV. 0
113 D13
115 VDD13
116 GND13
117 D11
118 D10
119 D9
121 D7
120 D8
122 D6
124 D4
123 D5
126 VDD14
125 GND14
128 D2
D1
127 D3
PIN CONFIGURATION
AD6435
PIN DESCRIPTION
The AD6435 contains 91 signal pins, 33 output pins, 35 input pins, and 24 bidirectional pins. There are also 5 test pins and
28 digital supply pins, 2 analog supply pins, and 1 PLL bias pin for the PLL.
PIN FUNCTION DESCRIPTIONS
Pin No.
Pin Name
Type
Description
1–2
3
4
5
6
7
8
9
10
11
12
13
14
D1, D0
TEST4
SIMPLX_TX
SIMPLX_CLKI
SIMPLX_CLKO
VDD1
GND1
SIMPLX_RX
DUPLX_TX
DUPLX_CLKI
DUPLX_CLKO
DUPLX_RX
RX_BUF
I/O
Input
Input
Input
Output
Supply
Supply
Output
Input
Input
Output
Output
Output
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33, 34
35
36
37
38
39
40
41
42
43–50
51
52
53–60
VDD2
GND2
RFS
RX_FR
RX_SPFR
RX_SPFRI
TX_BUF
TFS
GND3
VDD3
TX_FR
TX_SPFR
MCLK_OUT
TEST0
TEST1
RT_NCO
GND4
VDD4
NC
PLL_GND
PLL_VDD
PLL_RBIAS
NC
TEST2
TEST3
VDD5
GND5
M_D7–0
VDD6
GND6
M_A0–7
Supply
Supply
Output
Output
Output
Output
Input
Output
Supply
Supply
Output
Output
Output
16-Bit Data Bus for DSP Port. See also 111:114, 117:124, 127:128.
Tie to Ground Through a 10 kΩ Resistor.
Input Downstream Data at CO. Pin not used at RT.
Input Clock at CO for Downstream Data. Pin is not used at RT.
Recovered Downstream Clock at RT. Pin not used at CO.
3.3 V.
Ground.
Received Downstream Data at RT. Pin not used at CO.
Input Duplex Data.
Input Duplex Clock.
Recovered Duplex Clock.
Received Duplex Data Stream.
TICL Bypass—RX Data Buffer. If TCIL is not used, this pin must have a
pull-up resistor.
3.3 V.
Ground.
TICL Bypass—RX Byte Sync.
TICL Bypass—RX Frame Sync. 10 kΩ to Ground.
TICL Bypass—TICL Superframe Sync.
TICL Bypass—RX Interleaved Superframe Sync.
TICL Bypass—TX Data Buffer.
TICL Bypass—TX Byte Sync.
Ground.
3.3 V.
TICL Bypass—TX Frame Sync.
TICL Bypass—TX Superframe Sync.
TICL Bypass—Output MCLK.
No Connection.
No Connection.
Mode Pin, 1 = RT Mode, 0 = CO Mode.
Ground.
3.3 V.
No Connect.
PLL Analog Ground.
PLL Analog Power.
Tie to Ground Through a 30 kΩ Resistor.
No Connect.
Tie to Ground Through a 10 kΩ Resistor.
No Connection.
3.3 V.
Ground.
Data for Interleave Ram.
3.3 V.
Ground.
Address Bus for Interleave Ram. See also Pins 60–66.
Supply
Supply
Input
Three-State
Supply
Supply
I/O
Supply
Supply
Output
–4–
REV. 0
AD6435
PIN FUNCTION DESCRIPTIONS (Continued)
Pin No.
Pin Name
Type
Description
61
62
63–69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89–93
94
95
96
97–104
105
106
107
108
109
110
111–114
115
116
117–124
125
126
127, 128
GND7
VDD6
M_A8–14
NM_WE
VDD8
GND8
NM_OE
MCLK
TX _DREQ
TX _BS
TX _SDATA
TX _FRM
VDD9
GND9
TX _RX_SCLK
RX_BS
RX_DREQ
RX_SDATA
RX_FRM
A13
GND10
VDD10
A12–A8
DSP_CLK
GND11
VDD11
A7–0
VDD12
GND12
NCS
NRD
NWR
NRESET
D15–D12
VDD13
GND13
D11–D4
GND14
VDD14
D3–D2
Supply
Supply
Output
Output
Supply
Supply
Output
Input
Input
Output
Output
Input
Supply
Supply
Input
Input
Output
Input
Input
Input
Supply
Supply
Input
Input
Supply
Supply
Supply
Supply
Supply
Input
Input
Input
Input
I/O
Supply
Supply
I/O
Supply
Supply
I/O
Ground.
3.3 V.
Address Bus for Interleave Ram. See also Pins 50–57.
Write Enable for Interleave Ram.
3.3 V.
Ground.
Output Enable for Interleave Ram.
The AD6435 Master Clk (35.328 MHz).
Data Request Provided by the AD6436.
Transmit Byte Strobe Provided by the AD6435.
Transmit Serial Data Provided by the AD6435.
Transmit Frame Strobe Provided by the AD6436.
3.3 V.
Ground.
Transmit and Receive Serial Clock.
Receive Byte Strobe Provided by the AD6436.
Receive Data Request Provided by the AD6435.
Receive Serial Data Provided by the AD6436.
Receive Frame Strobe Provided by the AD6436.
14-Bit Address Bus for DSP Port. See also 86–90 and 94–101.
Ground.
3.3 V.
14-Bit Address Bus for DSP Port. See also 83 and 94–101.
DSP Output Clock.
Ground.
3.3 V.
14-Bit Address Bus for DSP Port. See also 83 and 86–90.
3.3 V.
Ground.
DSP Memory Select. Active Low.
DSP Memory Read Enable, Active Low.
DSP Write Enable, Active Low.
Reset Pin, Active Low.
16-Bit Data Bus for DSP Port. See also 1–2, 117–124, 127–128.
3.3 V.
Ground.
16-Bit Data Bus for DSP Port. See also 1–2, 111–114, 127–128.
Ground.
3.3 V.
16-Bit Data Bus for DSP Port. See also 1–2, 111–114, 117–124.
REV. 0
–5–
AD6435
INTRODUCTION
The AD6435 is the interface chip in the AD20msp910 ADSL
chipset, connecting the core transceiver functions to the external
system. The other portions within the AD20msp910 chipset are
the AD6436 (which connects to the AD6435 and is responsible
for the core DMT signal processing), the AD6437 analog frontend IC, the AD816 driver/receiver and ADTSP2183, which is
used as the system control processor. An object code licence for
all modem software is supplied with the AD20msp910 chipset.
The AD6435 implements a generic interface, with straightforward synchronous clock and data streams corresponding to
simplex and duplex bearer channels. These can be considered as
the AS0 (simplex) and LS0 (duplex) streams as per the standard,
but can run at any rate; the “duplex” channel can be treated as
two independent streams, one up and one down. This implementation is a simplified variant of that described in ANSI T1.413.
It is easy to use this structure to connect to the rest of the system, or to external devices, such as framers or dedicated ICs for
particular protocols. Variants of the AD6435 with support for
specific functions or interfaces (e.g., ATM, Ethernet) are under
development.
When used as part of the AD20msp910 ADSL chipset, the
internal functionality is under the control of the firmware supplied with the ADTSP2183, and the Messaging Protocol (MP)
implemented there. This protocol supplies a hardware-neutral
method of controlling the operation of the ADSL chipset, which
will be compatible between different hardware implementations.
The AD6435 can implement rate adaptive ADSL (RADSL).
This is under the control of the MP, and several different modes
are supported.
The absolute maximum data rate of the AD6435 is 12 Mbps
downstream, and 4 Mbps upstream. However, the rate depends
primarily on the channel conditions, and these rates will not be
achieved on real loops, with attenuation and crosstalk.
a. One codeword per frame in the fact and/or interleaved
data portion of a frame.
A(13:0)
D(15:0)
DSP_CLK
NRD
NWR
NCS
c. Multiple frames per codeword on the interleaved portion
of the frame only, up to 20 frames per codeword. The
number of checkbytes must be an integer multiple of the
number of frames in the codeword.
RX_FRM
RX_BS
RX_SDATA
RX_DREQ
DUPLX_RX
DUPLX_CLKO
DUPLX_CLKI
DUPLX_TX
SIMPLX_CLKI
SIMPLX_TX
SIMPLX_CLKO
SIMPLX_RX
M_A(14:0)
M_D(7:0)
NM_WE
NM_OE
DME INTERFACE
TX_SDATA
DTIR
MCLK
RT_NCO
b. Multiple codewords per frame in the fast and/or interleaved data portion, providing the codeword length evenly
divides into the output (DME) frame length.
TX_DREQ
TX_FRM
TX_BS
TX_BUF
TX_FR
TFS
TX_SPFR
MCLK_OUT
INTERLEAVE RAM
DATA INTERFACE
• The digital processing section (Digital Interface Area or
“DIA”), which is responsible for error correction, scrambling, interleaving, AOC and control operations. This is
based on the earlier AD6442 device. This is a highly programmable system, whose operation is not restricted to the
operating modes as defined in ANSI T1.413, but which
could be used in variety of systems. The DIA supports the
following codeword cases:
TX_RX_SCLK
TEST(4:0)
There are two main blocks within the AD6435:
RX_BUF
RFS
RX_FR
RX_SPFR
RX_SPFRI
NRESET
TICL BYPASS INTERFACE
ADTSP2183 INTERFACE
CONTROL INTERFACE
Figure 1. Functional Diagram
d. Codewords may span superframes.
• The interface block (Transceiver Interface and Control Logic
or “TICL”), which handles the framing, signal buffering and
data retiming functions required to support clean synchronous
data streams. (This essentially corresponds to the transmission
convergence layer of a stack.) As some designs may not require
the TICL block, there is a bypass mode, in which this block is
powered down and there is access to the unformatted/unframed
data stream from the DIA.
This data sheet gives a user’s description of the AD6435. It
describes functionality and interfacing, but does not give any
details of the internal structure. For details of the internal structure, see the AD6435 User’s Manual, available on request.
INTERFACES
The standard interface is a very straightforward buffered and
demultiplexed synchronous connection. It is physically the same
at both ATU-R and ATU-C, and presents four channels—
simplex in and out, duplex in and out—with just two signals per
connection, clock and data (obviously, only three of these channels can be used at an end; with the ATU-C using simplex_in
and the ATU-R simplex_out). These streams are independent
and can be used asynchronously of one another. No framing
signals are provided.
The “duplex” stream can be used as a true duplex carrier (same
rates upstream and downstream) or the two may be independent
(i.e., the chipset has two simplex downstream paths, one fast
and one slower, and one simplex upstream).
–6–
REV. 0
AD6435
Table I. Interface Descriptions
Name
Description
duplex_rx
Duplex data output from the AD6435 (i.e.,
data received).
Clock associated with duplex_rx (output).
Duplex data input to the AD6435 (i.e.,
data to be transmitted).
Clock associated with duplex_tx input.
Simplex data output from the AD6435.
ATU-R: downstream data received.
ATU-C: not used.
Clock associated with simplex_rx (output).
Simplex data input to the AD6435.
ATU-R: not used.
ATU-C: downstream data to be sent.
Clock associated with simplex_tx (input).
duplex_clko
duplex_tx
duplex_clki
simplex_rx
simplex_clko
simplex_tx
simplex_clki
PAYLOAD DATA IN
In general tx clock signals (i.e., duplex_clcki, simplex_clki)
are input to the AD6435, while the received data clock signals (duplex_clko, simplex_clko) are outputs. In other words,
the sending modem (at ATU-C or ATU-R) supplies the clock
to the AD6435, and the receiving modem’s AD6435 recovers it
(using a digital phase locked loop) and supplies it to the external
system. The channels all have separate—independent—clocks.
There are two exceptions; the duplex streams can be “locked” with
a single clock or, in a “one down/one up” system typical for data
applications, the unused DPLL can be programmed to be a clock
source at the desired data rate for the tx channel.
To avoid overflow/underflow of internal buffers, the clock rate
of the streams should be held roughly constant. As such, although a degree of jitter or rate variation is supported, pure
burst-mode is not, and idle cell insertion (deletion) is necessary
and must be implemented by an external device.
Alternatively, the buffering multiplex/demultiplex and bit-stuff/
rob operations may be bypassed (TICL bypass operation).
These blocks are then powered down, reducing the AD6435’s
power consumption. The interface presented is then a “raw”
stream of upstream and downstream data. As the elastic store
has been disabled, these have the relic of the ADSL line superframe structure, and will show an irregular clock (with a pause
for every 69th frame). This mode is compatible with the AD6442
DIA interface and is suited to packet (e.g., ATM) operation. It
results in a slight power saving.
PAYLOAD DATA OUT
ELASTIC STORE
EOC
REMOVE
EOC INSERT
SYNC
FRAMER
AD6435
CRC
CRC
DETECT
RAM
ARBITRATION
SCRAMBLER
FEC
ENCODE
INTERLEAVER
FRAMER
NB: Although the AD6435 can implement the T1.413 standard, and includes the required framing/interfacing (e.g.,
elastic store, bit-stuffing/robbing), it does not support the full
optional suite of seven bearer streams (ASx and LSx) and
associated multiplexing/demultiplexing as defined in T1.413.
Instead, simple synchronous data streams are provided. These
are essentially AS0 (simplex) and LS0 (duplex) but with variable rate or rate adaptive (not merely fixed multiples of standard
PDH rates, as per Chapter 5 of T1.413). Additionally, the “duplex” stream can be treated as two independent streams, one up
and one down. Indeed, in many applications, only one stream in
each direction is required; in this case, the downstream duplex
path is not used.
UNSCRAMBLE
DE-INTERLEAVER
FEC
DECODE
RAM
TONE
SHUFFLE
TONE
REORDER
CONSTELLATION
ENCODE
CONSTELLATION
DECODE
AD6436
INVERSE
FFT
FFT
INTERPOLATE
DECIMATE
& TDQ
Further TC-layer operations can be defined by the system for
their requirements (e.g., for V.35, ATM or 10BaseT), and simply interfaced to the AD6435 serial ports.
INTERFACE TIMING
DAC
SERIAL DAC
(TO VCXO)
CONTROL
The DTIR contains simplex (AS) and duplex (LS) channels
that interface with the Central Office (CO) and Remote Terminal (RT). The DTIR contains a transmit serial port in which the
DTIR transmits a bit stream to the DME and a receive serial
port in which DTIR receives a serial bit stream from the DME.
Since the DIA is being treated as a black box, the TICL-DIA
interface will be defined here. This interface is similar to the
DIA-DME transmit and receive interfaces. The DTIR also
interfaces with a 32k × 8 Interleave RAM. The DTIR also has a
DSP host port that allows a DSP to monitor the DTIR and
control the data through the device.
ADC
AD6437
FILTER
PGA
FILTER
HYBRID
POTS
SPLITTER
RECEIVER
DRIVER
AD816
DRIVER/RECEIVER
Figure 2. AD20msp910 System Block Diagram
REV. 0
–7–
AD6435
and DUPLX_CLKI. The serial clock rate is completely variable
between 8 kbps and 4.096 Mbps. The interface operates identically at the CO and RT locations. The input interface can accept a continuous stream of data at a fixed frequency within the
duplex rate. The output interface on the other end transmits the
same continuous stream of data at the same fixed frequency.
This frequency is established and programmed into the registers
by the DSP during reset.
CO/RT INTERFACE TIMING
Simplex Serial Port
The simplex serial port consists of four pins, two outputs,
SIMPLX_RX and SIMPLX_CLKO, and two inputs, SIMPLX_
TX and SIMPLX_CLKI. The serial clock rate is completely
variable between 8 kbps and 12.288 Mbps. The interface
operates differently at the CO and RT locations.
DTIR XMT
RT RECEIVE
For the Duplex Rx channel, data is driven out of the AD6435
on the positive edge of the respective CLKO signal and should
be sampled by the external circuit on the negative edge.
SIMPLX_CLKO
SIMPLX_RX
For the Duplex Tx channel, the data is sampled by the AD6435
on the positive edge of the respective CLKO signal and should
be driven by the external circuit on the negative edge.
VALID DATA
tSRX-S
tSRX-H
DTIR XMT
SIMPLX_CLKI
DUPLX_CLKO
SIMPLX_TX
VALID DATA
tSTX-S
DUPLX_RX
tDRX-S
CO/RT XMT
Parameter
Description
tSRX-S
Setup Time of SIMPLX_RX from
Falling Edge of SIMPLX_CLKO
Hold Time of SIMPLX_RX from
Falling Edge of SIMPLX_CLKO
Setup Time of SIMPLX_TX from
Rising Edge of SIMPLX_CLKI
Hold Time of SIMPLX_TX from
Rising Edge of SIMPLX_CLKI
tSTX-H
tDRX-H
DTIR RECEIVE
DUPLX_CLKI
Table II. TX Serial I/F Timing
tSTX-S
VALID DATA
tSTX-H
Figure 3. Simplex Serial Port
tSRX-H
CO/RT RECEIVE
DTIR RECEIVE
CO XMT
Typ
DUPLX_TX
VALID DATA
tDTX-S
5 ns
tDTX-H
Figure 4. Duplex Serial Port
5 ns
Table III. TX Serial I/F Timing
5 ns
5 ns
At the CO, the two input pins SIMPLX_TX and SIMPLX_CLKI
are used while the two output pins SIMPLX_RX and SIMPLX_
CLKO are not functionally connected. The interface can operate at a continuous data stream into SIMPLX_RX at a fixed
frequency between 8 kbps and 12.288 Mbps. The data rate is
set while the DTIR is in reset and does not change without
going into the reset state again.
Parameter
Description
tDRX-S
Setup Time of DUPLX_RX from
Falling Edge of DUPLX_CLKO
Hold Time of DUPLX_RX from
Falling Edge of DUPLX_CLKO
Setup Time of DUPLX_TX from
Rising Edge of DUPLX_CLKI
Hold Time of DUPLX_TX from
Rising Edge of DUPLX_CLKI
tDRX-H
tDTX-S
tDTX-H
At the RT, the two output pins SIMPLX_RX and SIMPLX_
CLKO are used while the two input pins SIMPLX_TX and
SIMPLX_CLKI are not functionally connected. The interface can
operate at a continuous data stream out of SIMPLX_RX at a
fixed frequency between 8 kbps and 12.288 Mbps. The data
rate is set while the DTIR is in reset and does not change without going into the reset state again.
Typ
5 ns
5 ns
5 ns
5 ns
INTERLEAVE RAM INTERFACE
The DTIR (DIA) Interfaces an external 32k × 8 Interleave
RAM. The interleave RAM interface consists of M_A(14:0),
M_D(7:0), NM_WE, and NM_OE. When operating at 3.3 V
RAM must have access time less than 50 ns. For further information concerning the operation of the RAM access, consult the
DIA specification.
For the Simplex Rx channel, data is driven out of the AD6435
on the positive edge of the respective CLKO signal and should
be sampled by the external circuit on the negative edge.
DME INTERFACE TIMING
All signals transmitted by the DME to the DTIR are transmitted on the rising edge and sampled on the falling edge except for
the TX_DREQ signal that is transmitted by the DME on the
falling edge and sampled by the DTIR on the rising edge. All
output signals from the DTIR to the DME are transmitted by
the DTIR on the rising edge and received by the DME on the
rising edge.
For the Simplex Tx channel, the data is sampled by the AD6435
on the positive edge of the respective CLKO signal and should
be driven by the external circuit on the negative edge.
Duplex Serial Port
The duplex serial port consists of four pins, two outputs,
DUPLX_RX and DUPLX_CLKO, and two inputs, DUPLX_TX
–8–
REV. 0
AD6435
Parameter
Description
Typ
Units
TX Serial I/F Timing
tTFRM-S
tTFRM-H
tTDREQ-S
tTDREQ-H
tTBS-S
tTBS-H
tTD_S
tTD_H
Setup Time of TX_FRM from Falling Edge of TX_RX_SCLK
Hold Time of TX_FRM from Falling Edge of TX_RX_SCLK
Setup Time of TX_DREQ from Rising Edge of TX_RX_SCLK
Hold Time of TX_DREQ from Rising Edge of TX_RX_SCLK
Setup Time of TX_BS from Rising Edge of TX_RX_SCLK
Hold Time of TX_BS from Rising Edge of TX_RX_SCLK
Setup Time of TX_SDATA from Rising Edge of TX_RX_SCLK
Hold Time of TX_SDATA from Rising Edge of TX_RX_SCLK
5
15
5
15
10
0
5
0
ns
ns
ns
ns
ns
ns
ns
ns
TX_RX_SCLK
TX_FRM
tTFRM-S
tTFRM-H
TX_DREQ
tTDREQ-S tTDREQ-H
TX_BS
tTBS-S
TX_SDATA
tTBS-H
VALID
DATA
tTD-S
tTD-H
Figure 5. TX Serial I/F Timing
Parameter
Description
Typ
Units
RX Serial I/F Timing
tRFRM-S
tRFRM-H
tRDREQ-S
tRDREQ-H
tRBS-S
tRBS-H
tRD-S
tRD-H
Setup Time of RX_FRM from Falling Edge of TX_RX_SCLK
Hold Time of RX_FRM from Falling Edge of TX_RX_SCLK
Setup Time of RX_DREQ from Rising Edge of TX_RX_SCLK
Hold Time of RX_DREQ from Rising Edge of TX_RX_SCLK
Setup Time of RX_BS from Falling Edge of TX_RX_SCLK
Hold Time of RX_BS from Falling Edge of TX_RX_SCLK
Setup Time of RX_SDATA from Falling Edge of TX_RX_SCLK
Hold Time of RX_SDATA from Falling Edge of TX_RX_SCLK
5
15
5
0
5
15
5
15
ns
ns
ns
ns
ns
ns
ns
ns
TX_RX_SCLK
RX_FRM
tRFRM-S tRFRM-H
RX_DREQ
tRDREQ-S tRDREQ-H
RX_BS
tRBS-S tRBS-H
RX_SDATA
VALID
DATA
tRD-S
tRD-H
Figure 6. RX Serial I/F Timing
REV. 0
–9–
AD6435
TX_RX_SCLK:
RX_FRMRX_FRM:
RX_BS:
RX_SDATA:
RX_DREQ:
TX Serial Port
The TX serial interface between the DME and DTIR uses five
(5) signals:
TX_RX_SCLK:
TX_DREQ:
TX_FRM:
TX_BS:
TX_SDATA:
Serial clock provided by DME.
Data request provided by DME.
Frame strobe provided by DME.
Byte strobe provided by DTIR.
Serial data provided by DTIR.
Serial clock provided by DME.
Frame strobe provided by DME.
Byte strobe provided by DME.
Serial data provided by DME.
Data request provided by DTIR.
DSP PORT
The DSP port consists of a 14-bit address bus, A[13:0], a 16-bit
data bus, D[15:0], DSP_CLK and three bus control pins,
NRD, NWR, NCS.
RX Serial Interface
The RX serial interface between the DME and DTIR uses five
(5) signals:
Parameter
Min
Max
Unit
8
14
ns
ns
ns
Read Operation
Timing Requirements:
NRD Low to Data Valid
tRDD
tAA
A0–A13, NCS to Data Valid
tRDH
Data Hold from NRD High
0
Switching Characteristics:
NRD Pulsewidth
tRP
tCRD
DSP_CLK High to NRD Low
tASR
A0–A13, NCS Setup before NRD Low
tRDA
A0–A13, NCS Hold after NRD Deasserted
tRWR
NRD High to NRD or NWR Low
12
3
2
5
12
16
ns
ns
ns
ns
ns
NOTE:
DSP clock 28 MHz (35.7 ns)
DSP_CLK
A0–A13
NCS
tRDA
NRD
tASR
tRP
tCRD
tRWR
D
tAA
tRDD
tRDH
NWR
Figure 7. Read Operation
–10–
REV. 0
AD6435
Parameter
Min
Max
Unit
Write Operation
Switching Characteristics:
Data Setup before NWR High
tDW
tDH
Data Hold after NWR High
tWP
NWR Pulsewidth
tWDE
NWR Low to Data Enabled
tASW
A0–A13, NCS Setup before NWR Low
tDDR
Data Disable before NWR or NRD Low
tCWR
DSP_CLK High to NWR Low
tAW
A0–A13, NCS, Setup before NWR Deasserted
tWRA
A0–A13, NCS Hold after NWR Deasserted
tWWR
NWR High to NRD or NWR Low
10
6
12
0
2
1
3
17
5
12
16
NOTE:
DSP clock 28 MHz (35.7 ns)
DSP_CLK
A0–A13
NCS
tWRA
NWR
tASW
tWWR
tWP
tAW
tDH
tCWR
D
tWDE
tDW
NRD
Figure 8. Write Operation
REV. 0
–11–
tDDR
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
AD6435
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm).
0.063 (1.60)
TYP
C3227–3–10/97
128-Lead Plastic Thin Quad Flatpack
(ST-128)
0.630 (16.00) BSC
0.551 (14.00) BSC
0.030 (0.75)
0.024 (0.60)
0.018 (0.45)
103
102
128
1
SEATING
PLANE
TOP VIEW
0.787 0.866
(20.00) (22.00)
BSC
BSC
(PINS DOWN)
0.003 (0.08)
MAX
38
65
64
39
0.057 (1.45)
0.053 (1.40)
0.018 (1.35)
0.020 (0.50)
BSC
0.011 (0.27)
0.009 (0.22)
0.007 (0.17)
PRINTED IN U.S.A.
0.006 (0.15)
0.002 (0.05)
–12–
REV. 0