ETC FYAB8A2-2

Proximity Sensors
14 mm Diameter Preleaded Cylindrical Metal Specialty Sensors
3-Wire DC Types
FY Series
FEATURES
1 Factory Mutual approved for non-incendive Class I, Division 2, Groups A, B, C, D and
Class II, Division 2, Group G hazardous locations (NPN outputs only)
1 TTL compatible, 0.5 VDC saturation voltage (NPN outputs only)
1 Sealed to NEMA 3, 3R, 3S, 4, 12, 13
1 PNP outputs (Current Sourcing) also available
1 Threaded aluminum bushing
1 –30 to +70° C (–22 to +160° F) temperature range
1 False pulse suppression, line transients and noise protection
ORDER GUIDE
Sensor
Package
Style
Sensing
Range
mm (in.)
Sensor
Type
14 mm (.55 in.)
3 (.12)
Shielded
3-wire
DC
8 (.31)
Unshielded
3-wire
DC
LED
Sw.
Freq.
Standard
Target*
mm (in.)
NO
300 Hz
14 (.55)
NO
200 Hz
14 (.55)
Output
Type
Input
Voltage
Catalog
Listing
NPN, N.O.**
PNP, N.O.
8.5-20
FYAA3A1-2
FYAA3J1-2
NPN, N.O.**
PNP, N.O.
19-30
FYAA3A2-2
FYAA3J2-2
NPN, N.O.**
NPN, N.O.**
8.5-20
19-30
FYAB8A1-2
FYAB8A2-2
SPECIFICATIONS
WIRING DIAGRAMS
Sensor Type
Sinking (NPN)
Sourcing (PNP)
Load Current, min./max.
0-170 mA
0-170 mA
Leakage Current, max.
50 µA
50 µ A
Voltage Drop, max.
0.5 V sinking
2.6 V sourcing
Current Consumption, max.
25 mA
Inrush Current
—
Repeatability, Shielded
± 1%
Repeatability, Unshielded
± 3%
Hysteresis
2-15%
Sensing Face Material
Rynite
Housing Material
Aluminum
Cable Type
PVC jacket, 22 gage
MOUNTING DIMENSIONS
(For reference only)
Proximity
*Square of mild steel, 1 mm (.04 in.) thick
**TTL compatible, Factory Mutual approved for non-incentive Class I, Division 2, Groups A, B, C, D and Class II, Division 2, Group G hazardous locations.
mm
in.
NPN (Sinking) N.O.
PNP (Sourcing) N.O.
Do not place connecting cables of DC sensors in conduit with AC control wiring. Place
in separate conduit or with wiring to other
low voltage low current solid state devices.
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
B33