ETC 77209

772 SERIES
Pulse Transformers
features
600Vrms Working
UL 94V-0 Package Material
2500/4000Vrms Isolation
Inductance to 16mH
Up to 480 V S ET
PCB Mounting
Custom Parts Available
The 772 series of pulse transformers are
intended for medium power applications in
switch mode power supplies and thyristor/triac firing (eg motor control applications). The standard turns ratios may be
modified by connecting several windings in
series.
pin connections
8 Pin DIP (top view)
1
3
Secondary 1
4
Primary
5
Secondary 2
2
6
4 - 772 SERIES
description
Pulse Transformers
4-17
772 SERIES
Pulse Transformers
absolute maximum ratings over operating free air temperature range
Operating free air temperature range . . . . . . . .
Storage temperature range . . . . . . . . . . . . .
Lead Temperature 1.5mm from case for 10 seconds
Isolation voltage (flash tested for 1 second) . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . 0°C to 70°C
. --60°C to 125°C
. . . . . . 300°C
. . . . 2500Vrms
electrical specifications over operating free air temperature range
Turns Ratio
2%
77209
77208
77207
77206
77205
77204
77203
77202
Parameter
77201
Part Number
Units
1:1
1:1:1 2:1:1
1:1
1:1:1 2:1:1
1:1
1:1:1 2:1:1
Primary Inductance
(min.)
1.00
1.00
1.00
4.00
4.00
4.00
16.3
16.3
16.3
mH
Primary ET Constant
120
120
120
240
240
240
482
482
482
V s
Leakage Inductance
(max.)
2.0
3.0
3.5
5.0
11
11
18
40
40
H
Interwinding
Capacitance (max.)
50
40
30
55
35
35
65
40
40
pF
0.25
0.25
0.24
0.86
0.90
0.84
3.50
3.60
3.50
0.23
0.22
0.12
0.83
0.76
0.38
3.40
3.10
1.60
----
0.28
0.15
----
1.10
0.50
----
4.20
2.00
DC Resistance (max.)
Primary Winding
DC Resistance (max.)
Secondary 1 Winding
DC Resistance (max.)
Secondary 2 Winding
Package Style
Note : All data taken at T A = 25°C.
4-18
1
772 SERIES
Pulse Transformers
outline dimensions
8 Pin DIP package style
1
4 - 772 SERIES
recommended footprint details
All dimensions in mm XX.X
0.50, XX.XX
0.25
Pulse Transformers
4-19