ETC ASA2815D

PD - 94540
ASA28XXD SERIES
28V Input, Dual Output
ADVANCED ANALOG
HIGH RELIABILITY
HYBRID DC/DC CONVERTERS
Description
The ASA28XXD Series of DC/DC converters are high
reliability thick film hybrid converters that use flyback
topology operating at a nominal frequency of 550Khz.
High input to output isolation is achieved through the
use of transformers in the flyback power and feedback
circuits.
The advanced feedback design provides fast loop response for superior line and load transient characteristics and offers greater reliability than devices incorporating optical feedback circuits.
This device is designed to meet MIL-STD-704 input
requirements offering full performance over a 16 to 40
volt input range. Output Power of up to 5 watts is available for either balanced or unbalanced loads.
Connecting the inhibit pin (pin 5) to the input common
(pin 7) will cause the converter to shut down. It is recommended that the inhibit pin be driven by an open
collector device capable of sinking at least 400µA. The
open circuit voltage of the inhibit pin is 11.5 ±0.5 volts.
These converters are manufactured in a facility fully
qualified to MIL-PRF-38534. All processes used to
manufacture these converters have been qualified to
enable Advanced Analog to deliver compliant devices.
Three standard temperature grades are offered with
the screening options. Refer to Part Number section.
The CH grade converters are fully compliant to MILPRF-38534 for class H. The HB grade converters are
processed with the same screening as the CH grade,
but do not have class H element evaluation as required
by MIL-PRF-38534. These two grades are fully tested
and operate over the full military temperature range
without derating of output power. A commercial grade
is also available. Variations in electrical, mechanical
and screening can be accommodated. Extensive computer simulation using complex modeling enables rapid
www.irf.com
ASA
Features
n
n
n
n
n
n
n
n
n
n
n
Up To 5 Watt Output Power
±5, ±12, ±15 Volts Outputs
High Reliability
Wide Input Voltage Range -16 To 40 Volts
Indefinite Short Circuit and Overload
Protection
Popular Industry Standard Pin-Out
Military Screening
Parallel Seam Welded Package
No External Capacitors Required
Input Voltage Surge Protected to
MIL-STD-704
Under Voltage Lockout
design modification to be provided. Contact
Advanced Analog with specific requirements.
1
09/12/02
ASA28XXD Series
Specifications
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Power Output
Soldering
Temperature Range
-0.5 V to 50 V Continuous. 80 V, 100 mSec
Internally limited (6.5 W typical)
300°C for 10 Sec.
Operating
-55°C to +125°C Case
Storage
-65°C to +150°C
ASA2805D/XX
ASA2812D/XX
ASA2815D/XX
Group A
Subgroups
Min
Max
Min
Max
Min
Max
1
±4.95
±5.05
±11.88
±12.12
±14.85
±15.15
2, 3
±4.90
±5.10
±11.76
±12.24
±14.70
±15.30
VIN = 16, 28, and 40 V dc
either output
1, 2, 3
200
1000
84
333
67
267
mA
VIN = 16, 28 and 40 V dc
1, 2, 3
470
200
290
mV PP
VIN = 16, 28, and 40 V dc
1, 2, 3
50
50
50
mV
1, 2, 3
50
50
50
mV
20% to 80% load change
1, 2, 3
15
8.0
8.0
%
IOUT = 0
Pin 5 connected to pin 7
1, 2, 3
12
12
12
60
60
60
100
100
100
Conditions
-55° ≤ TC ≤+125°C
VIN = 28V dc ±5% CL = 0
unless otherwise specified
TEST
Output voltage
Output current
IOUT = 0
1, 2
3, 4
Output ripple voltage
Line regulation
4
Unit
V
IOUT = 0, 50%, 100% IMAX
4
Load regulation
VIN = 16, 28, and 40 V dc
IOUT = 0, 50%, 100% IMAX
5
Cross regulation
Input current
IOUT = 0 Pin5 open
3, 4
Input ripple current
Efficiency
IOUT = IMAX
4
Capacitive load
1, 3
70
71
71
2
66
68
68
Input to output or any pin to
case (except pin 8) at 500 V
dc, Tc = +25° C
1
100
100
100
No effect on dc performance,
total for both outputs
4
200
IOUT = IMAX
Isolation
6, 7
Power dissipation load fault
1, 2, 3
Overload
8
1, 2, 3
Short circuit
4
Switching frequency
IOUT = IMAX
IOUT = 50% ó 100% IMAX
Output response to step
transient load changes
4, 9
IOUT = 50% ó 100% IMAX
4, 9, 10
IOUT = 0 ó 50% IMAX
step line changes
4, 7, 11
Recovery time transient step
line changes
4, 7, 10, 11
Turn on overshoot
Turn on delay
4
4, 12
Load fault recovery
4, 5, 6
IOUT = 0 ó 50% IMAX
Recovery time, step
transient load changes
Output response transient
4, 5, 6
mA PP
%
MΩ
200
200
µf
4.0
4.0
4.0
W
2.0
2.0
2.0
500
600
500
600
500
600
-400
+400
-400
+400
-400
+400
-800
+800
-800
+800
-800
+800
KHz
mV pk
100
100
100
2000
2000
2000
4, 5, 6
VIN = 16 ó 40Vdc,IOUT= IMAX
4, 5, 6
VIN = 16 ó 40Vdc, IOUT= IMAX
4, 5, 6
1200
IOUT = 0 and IMAX
4, 5, 6
IOUT = 0 and IMAX
7
mA
-750
+750
- 750
+750
-750
µS
+750
mV pk
1200
1200
µS
600
600
600
mV pk
4, 5, 6
25
25
25
ms
4, 5, 6
25
25
25
ms
For Notes to Specifications, refer to page 3
2
www.irf.com
ASA28XXD Series
Notes to Specifications
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Parameter guaranteed by line, load, and cross regulation tests.
Up to 80 percent of full power is available from either output provided the total output does not exceed 5 W.
Bandwidth of DC to 20 MHz is guaranteed by design. Tested for 20 KHz to 2 MHz.
Load current split equally between +VOUT and -VOUT.
1.0 watt load on output under test, 1.0 to 4.0 watt load change on other output.
Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall
be guaranteed to the limits specified.
An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is
the condition of maximum power dissipation.
Load step transition time between 2 and 10 microseconds.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50
percent load.
Input step transition time between 2 and 10 microseconds.
Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from
enable pin (pin 5) with power applied to the input.
Available Screening Levels and Process Variations for ASA28XXD Series
Requirement
MIL-STD-883
Method
Temperature Range
No
Suffix
ES
Suffix
HB
Suffix
CH
Suffix
-20°C to +85°C
-55°C to +125°C
-55°C to +125°C
-55°C to +125°C
Element Evaluation
MIL-PRF-38534
ü
ü
ü
1010
Cond B
Cond C
Cond C
Constant Acceleration
2001,
500g
Cond A
Cond A
Burn-in
1015
48hrs @ 125°C
160hrs @ 125°C
160hrs @ 125°C
Internal Visual
2017
Temperature Cycle
Final Electrical (Group A)
¬
48hrs @ 85°C
MIL-PRF-38534
25°C
25°C
-55, +25, +125°C
-55, +25, +125°C
Seal, Fine & Gross
1014
Cond C
Cond A, C
Cond A, C
Cond A, C
External Visual
2009
¬
ü
ü
ü
* per Commercial Standards
Available Standard Military Drawing (SMD) Cross Reference
ASA2812D/CH
5962-9564801
ASA2815D/CH
5962-9464901
Part Numbering
ASA 28 05 D / CH
Model
Input Voltage
Screening
–
, ES, HB, CH
28 = 28V
Output Voltage
5 = ±5, 12 = ±12,
15 = ±15
www.irf.com
Outputs
S = Single
D = Dual
3
ASA28XXD Series
ASA28XXD Block Diagram
+Output
1
6
+Input
Return
2
-Output
3
Error
Amplifier
Return
Case
7
8
Enable
Controller
5
ASA28XXD Case Outline
Pin No.
1.075
0.800
1
2
3
0.270
4
7
6
0.025 ± .003 Dia Pins
Designation
1
Positive Output
2
Output Return
3
Negative Output
4
N/C
5
Enable
6
Positive Input
7
Input Return
8
Case
5
1.075
8
ASA28XXD Pin Designation
0.800
±.005
0.220
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 322 3331
ADVANCED ANALOG: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 09/02
4