ETC PD0120.223

SMT POWER INDUCTORS
PD0120 Series
NEW!
Low profile, surface mount package
Economical, high performance design
400 V DC isolation, coil to core
Electrical Specifications @ 25°C — Operating Temperature -40°C to +125°C
DCR
(mΩ)
Part Number
Inductance
@ Irated
(µH ±10%)
Irated 1
(ADC)
TYP
MAX
Inductance
@ 0 ADC
(µH ±10%)
PD0120.102
PD0120.152
PD0120.222
PD0120.332
PD0120.532
PD0120.702
PD0120.113
PD0120.183
PD0120.223
PD0120.373
PD0120.503
1.2
1.8
2.5
4.5
5.6
7.1
12.0
18.3
22.6
39.9
55.4
15.4
14.2
11.4
11.2
10.4
8.6
7.6
6.4
5.3
4
3.4
1.5
2.5
4.0
6.3
8.0
9.5
15.0
21.5
30.5
51.5
75.5
2.0
3.0
4.2
6.8
8.5
10.0
16.0
25.5
35.5
58.5
82.5
1.2
1.8
2.6
4.6
5.7
7.2
12.2
18.7
23.1
40.7
56.5
Saturation Current 2
(A)
25°C
100°C
29
24.3
20.6
15
13.6
12.6
9
7.6
6.8
5
4.3
Mechanical
24.6
19
17.6
13
11.6
10.6
8
6.6
6
4.6
3.8
Heating
Current 3
(A)
Core Loss
Factor 4
K0
15.4
14.2
11.4
11.2
10.4
8.6
7.6
6.4
5.3
4
3.4
5556
4444
3704
2778
2469
2222
1709
1389
1235
926
794
Schematic
.323 MAX
8,20
1
.004/0,10
.638 MAX
16,20
3
.059
1,50
2
1
4
.628 MAX
15,95
.453
11,50
.630
16,00
PD0120.XXX
Date Code
Country of
Origin
.236
6,00
2
Weight . . . . . . . . . . . . . .4.25 grams
Tape & Reel . . . . . . . . . . . .250/reel
Not actual
number of turns;
for reference only
SUGGESTED PAD LAYOUT
Dimensions: Inches
mm
Unless otherwise specified, all tolerances are ± .010
0,25
US 858 674 8100 • UK 44 1483 401 700 • France 33 3 84 35 04 04 • Singapore 65 287 8998 • Taiwan 886 2 2698 0228 • Hong Kong 852 2788 6588 • http://www.pulseeng.com
PRELIMINARY P567.P (10/02)
SMT POWER INDUCTORS
PD0120 Series
Notes from Tables
1. The rated current as listed is either the saturation current or the
heating current depending on which value is lower.
2. The saturation current is the current which causes the
inductance to drop by 10% at the stated ambient temperatures
(-40°C, 25°C and 125°C). This current is determined by placing
the component in the specified ambient environment and applying a short duration pulse current (to eliminate self-heating
effects) to the component.
3. The heating current is the dc current which causes the temperature of the part to increase by approximately 30°C. This current
is determined by mounting the component on a PCB with .25"
wide, 3 oz. equivalent copper traces, and applying the current
to the device for 30 minutes with no forced air cooling.
4. In high volt*time applications additional heating in the
component can occur due to losses in the inductor which may
neccessitate derating the current in order to limit the
temperature rise of the component. In order to determine the
approximate total losses (or temperature rise) for a given application both copper losses and core losses should be taken into
account.
Estimated Temperature Rise:
.833
Trise = Coreloss (mW) + DCRloss (mW)
(°C)
7.05
Coreloss = 2.5 x 10
-4
* ( Fsw(kHz)) 1.63 * (Kc * Et(mT))2.17 (mW)
DCRloss = Irms2 * DCR(mΩ) (mW)
IDC2 + dI
Irms =
2
½
(Arms)
2
Fsw(kHz) = switching frequency (kHz)
VD
Et = LdI =
(Vµs)
Fsw
dI = pk – pk ripple current across the component (A)
V = Voltage across the component (V)
D = Duty cycle
Inductance vs DC Current Characteristics
Open-Circuit Inductance , OCL (µH)
60.0
PD0120.503
50.0
PD0120.373
PD0120.223
PD0120.183
40.0
PD0120.113
PD0120.702
30.0
PD0120.532
PD120.332
20.0
PD0120.222
PD0120.152
10.00
0.0
PD0120.102
0
5
10
15
20
25
30
35
40
Normalized Idc (Amps)
For More Information :
UNITED STATES
(Worldwide)
UNITED KINGDOM
(Northern Europe)
FRANCE
SINGAPORE
(Southern Europe) (Southern Asia)
TAIWAN, R.O.C.
(Northern Asia)
HONG KONG
(China/Hong Kong)
12220 World Trade Drive
San Diego, CA 92128
U.S.A.
http://www.pulseeng.com
TEL: 858 674 8100
FAX: 858 674 8262
1 & 2 Huxley Road
The Surrey Research Park
Guildford, Surrey GU2 5RE
United Kingdom
TEL: 44 1483 401700
FAX: 44 1483 401701
Zone Industrielle
F-39270
Orgelet
France
TEL: 33 3 84 35 04 04
FAX: 33 3 84 25 46 41
3F-4, No. 81, Sec. 1
HsinTai Wu Road
Hsi-Chih, Taipei Hsien
Taiwan, R.O.C.
Tel: 886 2 2698 0228
FAX: 886 2 2698 0948
19/F, China United Plaza
1008 Tai Nan West Street
Cheung Sha Wan, Kowloon
Hong Kong, China
TEL: 852 2788 6588
FAX: 852 2776 1055
150 Kampong Ampat
#07-01/02
KA Centre
Singapore 368324
TEL: 65 287 8998
FAX: 65 280 0080
DISTRIBUTOR
Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product
names mentioned herein may be trademarks or registered trademarks of their respective owners.
Printed on recycled paper. ©2002, Pulse Engineering, Inc.