ETC 30KP43CA

30KP33
8700 E. Thomas Road
Scottsdale, AZ 85251
Tel: (480) 941-6300
Fax: (480) 947-1503
thru
30KP220A
DESCRIPTION
This data sheet defines a series of 30 kW Transient Voltage Suppressor
(TVS) series designed for use in applications where large voltage
transients can damage sensitive components. This series is available
from 33 to 220 volts with a selection of either 5% or 10% tolerance of the
Breakdown Voltage (VBR).
The 30 kW TVS series provides a peak pulse rating of 30,000 watts for
one millisecond and is designed for use in applications where induced
lighting presents a hazard to electronic circuitry.
FEATURES
•
•
•
30,000 Watts Peak Power dissipation at 25° C for
10/1000 micro second pulse
Available in voltage range from 33 to 220 Volts
UL 94V-0 Flammability classification
MAXIMUM RATINGS
•
•
•
•
•
•
30,000 W @10/1000 µs of peak power dissipation at
25° C
0
0
Operating Temperatures: -55 C to +150 C
0
0
Storage Temperature: -55 C to +150 C
Forward surge rating: 250 Amps, 1/120 second (one
half sine wave) at 25° C
Steady state power dissipation: 7.0 watts @ TA = 25°C
Pulse Repetition Rate: <.05%
MECHANICAL
•
•
•
•
Void free molded case
Weight 1.5 grams (approximate)
Body Marked with logo, device marking
code
Positive terminal cathode marked with
band or dot. Bidirectional not marked
for polarity
FIGURE 1
PEAK PULSE POWER vs PULSE TIME
ISO 9001 CERTIFIED
FIGURE 2
PULSE WAVE FORM
REV D 11/02/99
30KP33 thru 30KP220A
ELECTRICAL Characteristics @ 250C Unless otherwise specified
V(BR)
IT
Maximum
Clamping
@ IPP
10/1000 µs
VC
ID
IPP
VOLTS
VOLTS
mA
VOLTS
µAmps
Amps
mV/°C
30KP33
33
36.7-44.9
50
64.6
5000
496
42
30KP33A
33
36.7-40.6
50
58.6
5000
548
38
30KP36
36
40.0-48.9
50
68.2
5000
454
46
Part
Number
Breakdown
Voltage
V(BR) Volts
@
Rated
Stand-off
Voltage
VWM
Maximum Reverse
Leakage
@ VWM
Maximum
Peak Pulse
Current
Maximum V(BR)
Temperature
Coefficient
α VZ
30KP36A
36
40.0-44.2
50
61.8
5000
502
41
30KP40
40
44.4-54.3
20
75.8
1500
412
51
30KP40A
40
44.4-49.1
20
68.6
1500
456
46
30KP43
43
47.8-58.4
10
79.0
500
380
55
30KP43A
43
47.8-52.8
10
71.0
500
430
50
30KP45
45
50.0-61.1
5
80.7
150
372
57
30KP45A
45
50.0-55.3
5
73.0
150
410
52
30KP48
48
53.3-65.1
5
85.9
150
350
62
30KP48A
48
53.3-58.9
5
77.7
150
386
56
30KP51
51
56.7-69.3
5
91.5
50
328
66
30KP51A
51
56.7-62.7
5
82.8
50
362
60
30KP54
54
60.0-73.3
5
96.8
25
310
70
30KP54A
54
60.0-66.3
5
87.5
25
342
63
30KP58
58
64.4-78.7
5
104
15
288
76
30KP58A
58
64.4-71.2
5
94.0
15
320
68
30KP60
60
66.7-81.5
5
107
15
280
78
30KP60A
60
66.7-73.7
5
97.3
15
304
71
30KP64
64
71.1-86.9
5
115
10
260
84
30KP64A
64
71.1-78.6
5
104
10
288
76
30KP70
70
77.8-95.1
5
126
10
238
92
30KP70A
70
77.8-86.0
5
114
10
264
83
30KP75
75
83.3-102.0
5
135
10
222
100
30KP75A
75
83.3-92.1
5
122
10
246
89
30KP78
78
86.7-106.0
5
140
10
214
104
30KP78A
78
86.7-95.8
5
126
10
238
93
30KP85
85
94.4-115
5
152
10
198
113
30KP85A
85
94.4-104
5
137
10
218
102
30KP90
90
100-122
5
160
10
188
120
30KP90A
90
100-111
5
146
10
206
109
30KP100
100
111-136
5
179
10
168
134
30KP100A
100
111-123
5
162
10
186
121
30KP110
110
122-149
5
196
10
154
147
30KP110A
110
122-135
5
178
10
168
133
30KP120
120
133-163
5
214
10
140
161
30KP120A
120
133-147
5
193
10
156
145
30KP130
130
144-176
5
231
10
130
174
30KP130A
130
144-159
5
209
10
142
157
30KP150
150
167-204
5
268
10
112
202
30KP150A
150
167-185
5
243
10
124
183
30KP160
160
178-218
5
287
10
104
216
30KP160A
160
178-197
5
259
10
116
195
30KP170
170
189-231
5
304
10
98
229
30KP170A
170
189-209
5
275
10
110
207
30KP180
180
200-244
5
321
10
94
242
30KP180A
180
200-221
5
291
10
104
219
30KP200
200
222-271
5
356
10
84
269
30KP200A
200
222-245
5
322
10
94
243
30KP220
220
245-299
5
393
10
76
297
30KP220A
220
245-271
5
356
10
84
269
Note 1: Transient Voltage Suppressors are normally selected according to the reverse
“Stand Off Voltage” VWM which should be equal to or greater than the dc continuous peak
operating voltage level.
Note 2: For bidirectional construction, indicate a C or CA suffix after the part number.
ISO 9001 CERTIFIED
REV D 11/02/99