ETC PE-51509

TOROIDAL INDUCTORS
HIGH CURRENT
Cost-effective designs
Semi-encapsulated construction
Maximum operation temperature of
130°C (Ambient + Rise)
A 2:1 inductance swing from zero to
maximum current
Electrical Specifications @ 25°C
Part
Number
PE-51506
PE-51507
PE-51508
PE-51509
PE-51510
PE-51511
PE-51512
PE-51513
PE-51514
PE-51515
PE-51516
PE-51517
PE-51518
PE-51520
NOTES:
REFERENCE OPERATING VALUES
Inductance
ETOP1
IDC
Typical
(V-µSec)
(AMPS)
(µH)2
20 kHz 40 kHz
17.0
32.0
60.0
14.0
23.0
43.0
90.0
144.0
32.0
52.0
98.0
175.0
335.0
400
17.0
16.0
16.0
10.0
11.0
10.0
10.0
10.0
6.6
7.0
6.0
6.0
6.0
3.6
190
290
390
135
170
280
430
570
200
230
400
620
840
600
130
200
270
95
120
195
300
400
140
160
280
425
580
420
Energy
Storage
(µJ MIN)3
Inductance
No DC (µH)
(±20%)
2460
4100
7700
700
1400
2150
4500
7200
700
1275
1765
3150
6030
2700
40.0
70.7
120.0
28.5
43.5
85.5
158.0
262.0
60.5
92.0
188.0
315.0
571.0
688.0
DESIGN CONTROL VALUES
50 kHz
DCR
Size
Test mV
(Ω MAX)
Code
No DC5
140
270
470
73
130
210
420
700
110
190
310
560
1000
640
0.0065
0.0092
0.012
0.009
0.012
0.018
0.028
0.032
0.025
0.032
0.048
0.068
0.095
0.130
1. To prevent excessive temperature rise, limit ETOP to the rated ETOP specified.
This is not a saturation limit. Temperature rise of inductors is 40°C MAX at
MAX current and rated ETOP.
E MIN
PE-515XX
DATE CODE
COUNTRY OF ORIGIN
G MAX
A
B
C
D
E
F
G
H
D
B MAX
1.20/30,48
0.60/15,24
0.40/10,16
0.80/20,32
0.45/11,43
0.20/5,08
.015/0,381
1.20/30,48
2
1.44/36,57
0.80/20,32
0.60/15,24
0.90/22,86
0.70/17,78
0.20/5,08
0.03/0,76
1.44/36,57
3
1.60/40,64
0.80/20,32
0.60/15,24
0.90/22,86
0.70/17,78
0.20/5,08
0.03/0,76
1.72/43,68
4
1.95/49,53
0.91/23,11
0.70/17,78
1.20/30,48
0.90/22,86
0.20/5,08
0.03/0,76
2.00/50,80
0.081
0.081
0.081
0.057
0.057
0.057
0.057
0.057
0.040
0.040
0.040
0.040
0.040
0.036
H MAX
4. Design control test voltage is critical. Inductance increases with voltage.
1
3
4
5
1
2
3
4
5
1
2
3
4
5
3
Mechanicals
2. A 2:1 nominal inductance swing from no IDC to operating IDC gives improved
protection against current discontinuities at light loading. Inductance increases
with greater ETOP. Reference values occur at IDC and low flux density.
3. LI2 rating is the ability of the inductor to store energy.
2
Size
Code
Lead
Diameter
(in ±.003)
F MIN
± .010
5
2.30/58,42
1.11/28,19
0.90/22,85
1.50/38,10
1.00/25,40
0.20/5,08
0.03/0,76
2.30/58,42
3
1
1
Lead Dia.
(3 PLCs)
C ± .010
2
2
3
No Internal
Connections
A MAX
Dimensions: Inches
mm
Unless otherwise specified, all tolerances are ± .010
0,25
US 858 674 8100 • UK 44 1483 401 700 • France 33 3 84 35 04 04 • Singapore 65 287 8998 • Taiwan 886 2 2698 0228 • Hong Kong 852 2788 6588 • http://www.pulseeng.com
PC500.B (5/02)
36