ETC 70U80

Bulletin I2039 11/94
70/300U(R) SERIES
Stud Version
STANDARD RECOVERY DIODES
250A
300A
Features
Alloy diode
Peak reverse voltage up to 1000V
Popular series for rough service
Standard JEDEC types
Stud cathode and stud anode version
Typical Applications
Welders
Power supplies
Motor controls
Battery chargers
General industrial current rectification
Major Ratings and Characteristics
Parameters
70U
300U
Units
IF(AV)
250
300
A
150
130
°C
@ TC
IFSM
I2t
@ 50Hz
6550
A
@ 60Hz
6850
A
@ 50Hz
214
KA2s
@ 60Hz
195
KA2s
VRRM range
TJ
www.irf.com
100 to 1000
50 to 1000
-65 to 200
V
case style
DO-205AB (DO-9)
°C
1
70/300U(R) Series
Bulletin I2039 11/94
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage
V RRM , maximum repetitive
VRSM , maximum non-
IRRM max.
Code
peak reverse voltage
V
repetitive peak rev. voltage
V
TJ = 200°C
10
100
200
20
200
300
40
400
500
60
600
720
Type number *
70U
Type number
mA
60
80
800
960
100
1000
1200
Voltage
Code
V RRM , maximum repetitive
peak reverse voltage
V
VRSM , maximum nonrepetitive peak rev. voltage
V
5
50
100
40
10
100
200
40
20
200
300
40
30
300
400
40
40
400
500
40
60
600
720
40
80
800
960
35
100
1000
1200
30
300U
IRRM max.
TJ = 175°C
mA
* Also available as JEDEC series: 1N3735 through 1N3743; 1N2054 through 1N2068; 1N4044 through 1N4056.
Forward Conduction
Parameter
I F(AV)
I FSM
I 2t
70U
300U
Units
Max. average forward current
250
300
A
@ Case temperature
150
130
°C
6550
t = 10ms
No voltage
non-repetitive surge current
6850
t = 8.3ms
reapplied
5500
t = 10ms
100% VRRM
5750
t = 8.3ms
reapplied
Sinusoidal half wave,
214
t = 10ms
No voltage
Initial TJ = TJ max.
195
t = 8.3ms
reapplied
t = 10ms
100% VRRM
t = 8.3ms
reapplied
Maximum I2 t for fusing
A
KA2s
138
I 2 √t
Maximum I2 √t for fusing
V F(TO)
Max. value of threshold
voltage
Max. value of forward slope
resistance
V FM
2
180° conduction, half sine wave
Max. peak, one-cycle forward,
151
rf
Conditions
Max. peak forward voltage
2140
KA2 √s
0.610
V
0.751
mΩ
t = 0.1 to 10ms, no voltage reapplied
TJ = 200°C
1.30
--
V
(IFM x π x IF(AV) (785A peak), T J = 25°C
--
1.40
V
(IFM x π x IF(AV) (942A peak), TJ = 25°C
www.irf.com
70/300U(R) Series
Bulletin I2039 11/94
Thermal and Mechanical Specifications
Parameter
70/300U(R)
TJ
Max. junction operating temperature range
-65 to 200
T
Max. storage temperature range
-65 to 200
RthJC
Max. thermal resistance, junction to case
0.18
RthCS
Max. thermal resistance, case to heatsink
0.08
T
Max. allowed mounting torque +0 -20%
37
stg
Units
°C
DC operation
K/W
Approximate weight
Not lubricated threads
250
Case style
Mounting surface, smooth, flat and greased
Nm
28
wt
Conditions
Lubricated threads
g
DO-205AB (DO-9)**
JEDEC (See Outline Table)
** 302U-A uses IR case style B-26
∆RthJC Conduction
(The following table shows the increment of thermal resistence RthJC when devices operate at different conduction angles than DC)
Conduction angle
Sinusoidal conduction
Rectangular conduction Units
180°
0.020
0.015
120°
0.024
0.025
90°
0.031
0.034
60°
0.045
0.047
30°
0.077
0.077
Conditions
TJ = TJ max.
K/W
Ordering Information Table
Device Code
1
-
300
U
1
2
3
R
100
A
4
5
6
300
70
= Standard 300U device
= Standard 70U device
302
72
= 300U Top Threaded version
= 70U with Pinch Bolt
= Essential Part Number
= Flat Base, available only on 72UF Series
2
3
-
U
F
4
-
None = Normal Stud
R
= Stud Reverse Polarity (Anode to Stud)
5
-
None = Stud Normal Polarity (Cathode to Stud)
Voltage code: Code x 10 = VRRM (See Voltage Ratings table)
6
-
A
= Essential Part Number only for 300U Series
None = 70U Series
NOTE: For longer lead Contact Factory
www.irf.com
3
70/300U(R) Series
Bulletin I2039 11/94
Outline Table
19.18 (0.755)
MAX.
11.51 (0.453)
10.74 (0.423)
4.32 (0.170) MAX.
134.6 (5.30)
13.46 (0.530)
11.94 (0.470)
70U/300U-A Series
Conforms to JEDEC DO-205AB (DO-9)
27.94 (1.10)
DIA. MAX.
All dimensions in millimeters (inches)
MAX.
9.27 (0.365)
7.87 (0.310)
20.14 (0.7 9)
3.18 (0.125)
MAX.
UNTHREADED
PORTION
21.03 (0.8 3)
28.45 (1.12)
53.3 4 (2.10) MAX.
149.9 (5 .90)
8.89 (0.350)
DIA.
8.38 (0.330)
31.75 (1.250)
30.94 (1.218) ACROSS FLATS
3/4"-16UNF-2A*
19.02 (0.749)
DIA. MAX.
* METRIC DEVICE. M16 X 1.5 FOR 300U..AM
METRIC DEVICE. M20 X 1.5 FOR 300U..AMA
9.50 (0.374) MAX. DIA.
All dimensions in millimeters (inches)
3.18 (0.125)
MAX.
7.87 (0.310)
9.27 (0.365)
MAX.
27.94 (1.10) DIA. MAX.
20.14 (0.7 93)
14.99 (0.59)
55.63 (2.19)
16.76 (0.66)
ACROSS FLATS
28.4 5 (1.12)
302U-A Series
IR Case Style B26
18.29 (0.72)
21.03 (0.8 28)
16.51 (0.65)
58.67 (2.31)
3/8"-24UNF-2A
31.75 (1.250)
30.94 (1.218)
ACROSS FLATS
3/4"-16UNF-2A
19.02 (0.749)
DIA. MAX.
4
www.irf.com
70/300U(R) Series
Bulletin I2039 11/94
Outline Table
Pinch Bolt
43-8223
41 (1.61)
24
(0.94)
2.4
(0.09)
DIA. 11.25 (0.44)
5.5 (0.21) DIA.
13
(0.51)
28.45 (1.12) MAX.
7.87 (0.310)
6
(0.23)
9 (0.35) ±
0.1 (0.004)
DIA.
16
(0.62)
31.75 (1.250)
36 (1.41) A/C
33 (1.29)
30.94 (1.218)
ACROSS FLAT
Spring Clamp
43-8222
60 (2.36)
72UF Series
24
(0.94)
Flat Base
7 (0.27)
DIA.
FULL RAD.
50 (1.96)
All dimensions in millimeters (inches)
27.6 (1.08)
9.27 (0.365)
50 (1.97) MAX.
12 (0.47)
20
(0.78)
11.19 (0.44) DIA.
70UF supplied with spring clamp
72UF supplied with pinch bolt and spring clamp
200
70/300U(R) Series
R thJC (DC) = 0.18 K/W
180
Conduction Angle
160
140
30°
120
0
50
100
150
60° 90°
120°
180°
200
250
300
350
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
www.irf.com
Maximum Allowable Case Temperature (°C)
Maximum Allowable Case Temperature (°C)
48 (1.88)
200
70U/300U(R) Series
R thJC (DC) = 0.18 K/W
190
180
170
Conduction Period
160
150
140
30°
130
60°
90°
120°
120
180°
110
0
100
200
300
DC
400
500
Average Forward Current (A)
Fig. 2 - Current Ratings Characteristics
5
70/300U(R) Series
400
0.4
0.5
K/
W
K/ W
200
0. 7
150
1 K/
Conduction Angle
R
RMS Limit
ta
el
-D
250
K/
W
K/
W
W
K/
300
0.
2
0 .3
.1
=0
180°
120°
90°
60°
30°
350
SA
R th
Maximum Average Forward Power Loss (W)
Bulletin I2039 11/94
K/W
W
1.5 K
/W
100
70/300U(R) Series
TJ = 200°C
50
3 K/W
0
0
50
100
150
200
250
300
350
25
Average Forward Current (A)
50
75
100
125
150
175
200
Maximum Allowable Ambient Temperature (°C)
500
DC
180°
120°
90°
60°
30°
0 .7
Conduction Period
150
70/300U(R) Series
TJ = 200°C
100
50
R
RMS Limit
200
K/
ta
el
0. 5
K/
W
-D
250
0 .3
W
K/
300
0.
2
1
0.
350
=
400
A
hS
450
Rt
Maximum Average Forward Power Loss (W)
Fig. 3 - Forward Power Loss Characteristics
W
K /W
K/ W
1 K/
W
1.5 K/
W
3 K/ W
0
0
100
200
300
400
Average Forward Current (A)
500
25
50
75
100
125
150
175
200
Maximum Allowable Ambient Temperature (°C)
6000
At Any Rated Load Condition And With
Rated VRRM Applied Following Surge.
5500
Initial TJ = 200°C
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
5000
4500
4000
3500
3000
2500
2000
70/300U(R) Series
1500
1
10
100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Fig. 5 - Maximum Non-Repetitive Surge Current
6
Peak Half Sine Wave Forward Current (A)
Peak Half Sine Wave Forward Current (A)
Fig. 4 - Forward Power Loss Characteristics
7000
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration.
Initial T J = 200°C
No Voltage Reapplied
Rated VRRM Reapplied
6500
6000
5500
5000
4500
4000
3500
3000
2500
2000
70/300U(R) Series
1500
0.01
0.1
1
Pulse Train Duration (s)
Fig. 6 - Maximum Non-Repetitive Surge Current
www.irf.com
70/300U(R) Series
Bulletin I2039 11/94
Instantaneous Forward Current (A)
10000
1000
TJ = 25°C
TJ = 200°C
100
70/300U(R) Series
10
0
0.5
1
1.5
2
2.5
3
Instantaneous Forward Voltage (V)
Transient Thermal Impedance Z thJC (K/W)
Fig. 7 - Forward Voltage Drop Characteristics
1
Steady State Value
0.1
R thJC= 0.18 K7W
(DC Operation)
0.01
70/300U(R) Series
0.001
0.0001
0.001
0.01
0.1
1
10
Square Wave Pulse Duration (s)
Fig. 8 - Thermal Impedance ZthJC Characteristic
www.irf.com
7