SIRECTIFIER MBR20100FCT

MBR20100FCT
Power Schottky Rectifier - 20Amp 100Volt
□ Features
-Plastic package has Underwriters Laboratory Flammability Classifications 94V-0
-High Junction Temperature Capability
-Low forward voltage, high current capability
-High surge capacity
-Low power loss, high efficiency
ITO-220AB
L
B
□ Application
-AC/DC Switching Adaptor and other Switching Power Supply
-TFT-LCD and DVD Power Supply
M
C
D
K
A
□ Absolute maximum ratings
E
Symbol
Ratings
Unit
Conditions
IF(AV)
20
A
At Tc=125ºC
VRRM
100
V
IFSM
150
A
VF(max)
0.85
V
Tj
-50 to +175
ºC
Tstg
-50 to +150
ºC
Maximum Instantaneous
Forward Voltage
Maximum Reverse Current At
Rated DC Blocking Voltage
Voltage Rate of Change
Typical Thermal Resistance,
Junction to Case
Symbol
8.3ms single half sine-wafe
J
H
single shot
Tc=25ºC
0.75V
Tc=125ºC
50µA
Tc=25ºC
10mA
Tc=125ºC
dv/dt
10,000 V/µs
Rated VR
Rth (j-c)
4.0 ºC/W
Per diode
N
K
A2
DIM
0.85V
H
A1
At IF=10A, Tc=25ºC
Conditions
IR
I
reverse voltage
Ratings
VF
G
Maximum repetitive peak
□ Electrical characteristics
Parameters
F
A
B
C
D
E
F
G
H
I
J
K
L
M
N
DIMENSIONS
INCHES
MM
MIN
MAX
MIN
MAX
.577
.600
14.65 15.25
.386
.406
9.80
10.30
.102
.114
2.60
2.90
.258
.274
6.55
6.95
.315
.331
8.00
8.40
.148
.159
3.75
4.05
.508
.531
12.90 13.50
.089
.100
2.25
2.55
.022
.028
0.55
0.70
.022
.028
0.55
0.70
.126
.138
3.20
3.50
.173
.185
4.40
4.70
.055
.063
1.40
1.60
.102
.114
2.60
2.90
NOTE
Note: (1)Pulse Test : 380µs pulse width, 2% duty cycle
April 2004
http:// www.sirectifier.com
1
100
10
60
6
40
4
20
2
10
1
6
.6
4
.4
2
INSTANTANEOUS REVERSE LEAKAGE (µ AMPS)
INSTANTANEOUS FORWARD CURRENT (AMPS)
MBR20100FCT
25℃
1
.6
.4
.2
.1
.06
.04
.02
.01
TA=25℃
.2
.1
.06
.04
.02
.01
.006
.004
.002
.001
0.2
0.3
0.4
0.5
0.6
0.7
0.8
20
INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
Figure 1. Typical Forward Characteristics
75
100
125
150
175
Figure 2. Typical Reverse Characteristics
20
150
PEAK FORWARD SURGE CURRENT (AMPS)
AVERAGE FORWARD RECTIFIEDCURRENT (AMPS)
50
PERCENT OF RATED PEAK REVERSE VOLTAGE (VOLTS)
18
16
14
12
10
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
125
150
125
100
75
50
25
0
1
2
4
6
8 10
20
40
60 80 100
AMBIENT TEMPERATURE (℃)
NUMBER OF CYCLES AT 60Hz (CYCLE)
Figure 3. Forward Derating Curve
Figure 4. Peak Forward Surge Current