U05GH44,U05JH44 TOSHIBA RECTIFIER SILICON DIFFUSED TYPE U05GH44,U05JH44 HIGH SPEED RECTIFIER APPLICATIONS (FAST RECOVERY) Unit: mm Repetitive Peak Reverse Voltage: VRRM = 400, 600V Average Forward Current: IF (AV) = 0.5A Reverse Recovery Time: trr = 1.5µs Surface Mounting Plastic Mold Package MAXIMUM RATINGS (Ta = 25°C) CHARACTERISTIC Repetitive Peak Reverse Voltage SYMBOL U05GH44 VRRM U05JH44 Average Forward Current IF (AV) Peak One Cycle Surge Forward Current (Non−Repetitive) RATING UNIT 400 600 0.5 V A IFSM 20 (50Hz) A Junction Temperature Range Tj −40~125 °C Storage Temperature Range Tstg −40~125 °C ELECTRICAL CHARACTERISTICS (Ta = 25°C) CHARACTERISTIC SYMBOL TEST CONDITION JEDEC ― JEITA ― TOSHIBA 3-4D1A Weight: 0.06 g (typ.) MIN TYP. MAX UNIT Peak Forward Voltage VFM IFM = 0.5A ― ― 1.2 V Repetitive Peak Reverse Current IRRM VRRM = Rated ― ― 10 µA IF = 20mA, IR = 1mA ― ― 1.5 µs Reverse Recovery Time trr MARKING Abbreviation Code Part No. GH U05GH44 JH U05JH44 STANDARD SOLDERING PAD 1 2004-07-01 U05GH44,U05JH44 Handling Precaution The maximum ratings denote the absolute maximum ratings, which are rated values and must not be exceeded during operation, even for an instant. The following are the general derating methods that we recommend when you design a circuit with a device. VRRM: We recommend that the worst case voltage, including surge voltage, be no greater than 80% of the maximum rating of VRRM for a DC circuit and be no greater than 50% of that of VRRM for an AC circuit. VRRM has a temperature coefficient of 0.1%/°C. Take this temperature coefficient into account designing a device at low temperature. IF(AV): We recommend that the worst case current be no greater than 80% of the maximum rating of IF(AV). Carry out adequate heat design. If you can’t design a circuit with excellent heat radiation, set the margin by using an allowable Tamax-IF(AV) curve. This rating specifies the non-repetitive peak current in one cycle of a 50-Hz sine wave, condition angle 180. Therefore, this is only applied for an abnormal operation, which seldom occurs during the lifespan of the device. We recommend that a device be used at a Tj of below 100°C under the worst load and heat radiation conditions. Thermal resistance between junction and ambient fluctuates depending on the device’s mounting condition. When using a device, design a circuit board and a soldering land size to match the appropriate thermal resistance value. Please refer to the Rectifiers databook for further information. 2 2004-07-01 U05GH44,U05JH44 3 2004-07-01 U05GH44,U05JH44 RESTRICTIONS ON PRODUCT USE 030619EAA • The information contained herein is subject to change without notice. • The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others. • TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. • The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. • TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced and sold, under any law and regulations. 4 2004-07-01