GENERAL DESCRIPTION
Temperature measurement:
1 local on-chip temperature sensor
2 remote temperature sensors
3-current external temperature sensors with series
resistance cancellation (SRC)
PECI interface for CPU thermal information and support of
up to 4 PECI inputs on one pin
Fan drive and fan speed control
3 high frequency or low frequency PWM outputs for use
with 3-wire or 4-wire fans
4 TACH inputs to measure fan speed
OS independent automatic fan speed control based on
thermal information
Dynamic TMIN control mode to optimize system acoustics
Default startup at 100% PWM for all fans for robust
operation
Bidirectional THERM/SMBALERT pin to flag out-of-limit and
overtemperature conditions
GPIO functionality to support extra features
Can be used for loadline setting for voltage regulation,
LED control, or other functions
IMON monitoring for CPU current and power information
Footprint and register compatible with ADT7473/ADT7475/
ADT7476/ADT7476A family of fan controllers
SMBus interface with addressing capability for up to
3 devices
The ADT7490 is a dBCool® thermal monitor and multiple
PWM fan controller for noise-sensitive or power-sensitive
applications requiring active system cooling. The ADT7490
includes a local temperature sensor, two remote temperature
sensors including series resistance cancellation, and monitors
CPU temperature with a PECI interface. The ADT7490 can
drive a fan using either a low or high frequency drive signal,
and measure and control the speed of up to four fans so they
operate at the lowest possible speed for minimum acoustic noise.
The automatic fan speed control loop optimizes fan speed
for a given temperature using the PECI, remote, or local
temperature information. The effectiveness of the system’s
thermal solution can be monitored using the THERM input.
The ADT7490 also provides critical thermal protection to
the system using the bidirectional THERM/SMBALERT pin as
an output to prevent system or component overheating.
APPLICATIONS
Personal Computers
Servers
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2007 Analog Devices, Inc. All rights reserved.
ADT7490
FUNCTIONAL BLOCK DIAGRAM
ADDR SELECT
SCL
SDA
ADT7490
SMBus
ADDRESS
SELECTION
GPIO1
GPIO REGISTER
GPIO2
PERFORMANCE
MONITORING
THERM/
SMBALERT
TACH1
TACH2
TACH3
TACH4
PWM1
PWM2
PWM3
SERIAL BUS
INTERFACE
PWM
REGISTERS
AND
CONTROLLERS
(HF AND LF)
PECI
THERMAL
PROTECTION
ADDRESS
POINTER
REGISTER
FAN
SPEED
COUNTER
PWM
CONFIGURATION
REGISTERS
AUTOMATIC
FAN SPEED
CONTROL
ACOUSTIC
ENHANCEMENT
INTERRUPT
MASKING
DYNAMIC TMIN
CONTROL
PECI INTERFACE
VTT
ACOUSTIC
ENHANCEMENT
CONTROL
VCC
VCCP
INTERRUPT
STATUS
REGISTERS
+12VIN
INPUT
SIGNAL
CONDITIONING
AND
ANALOG
MULTIPLEXER
+5VIN
+2.5VIN
IMON
D1+
10-BIT
ADC
BAND GAP
REFERENCE
D1–
D2+
D2–
LIMIT
COMPARATORS
VALUE AND
LIMIT
REGISTERS
GND
Figure 1.
Rev. 0 | Page 2 of 76
06789-001
BAND GAP
TEMP. SENSOR
ADT7490
TABLE OF CONTENTS
Features...............................................................................................1
Limits, Status Registers, and Interrupts .......................................25
Applications .......................................................................................1
Limit Values .................................................................................25
General Description..........................................................................1
Interrupt Status Registers...........................................................26
Functional Block Diagram ...............................................................2
THERM Timer ............................................................................28
Revision History................................................................................3
Fan Drive Using PWM Control ................................................30
Specifications .....................................................................................4
Laying Out 3-Wire Fans.............................................................32
Absolute Maximum Ratings ............................................................6
Programming Trange .....................................................................35
Thermal Characteristics...............................................................6
Programming the Automatic Fan Speed Control loop ..............36
ESD Caution ..................................................................................6
Manual Fan Control Overview .................................................36
Pin Configuration and Function Descriptions .............................7
THERM Operation in Manual Mode.......................................36
Typical Performance Characteristics ..............................................9
Automatic Fan Control Overview ............................................36
Theory of Operation .......................................................................12
Step 1: Hardware Configuration ...............................................37
Feature Comparisons Between the ADT7490 and ADT7476A
.......................................................................................................12
Step 2: Configuring the Muxtiplexer........................................37
Start-Up Operation .....................................................................13
Serial Bus Interface .....................................................................13
Write Operations.........................................................................14
Read Operations..........................................................................15
SMBus Timeout...........................................................................16
Voltage Measurement Input.......................................................16
Additional ADC Functions for Voltage Measurements.........17
Temperature Measurement........................................................19
Thermal Diode Temperature Measurement Method.............21
Series Resistance Cancellation ..................................................22
Factors Affecting Diode Accuracy............................................22
Step 3: TMIN Settings for Thermal Calibration Channels .......38
Step 4: PWMMIN for Each PWM (Fan) Output .......................40
Step 5: PWMMAX for PWM (Fan) Outputs...............................40
Step 6: TRANGE for Temperature Channels ................................41
Step 7: TTHERM for Temperature Channels ................................43
Step 8: THYST for Temperature Channels...................................44
Programming the GPIOs ...........................................................46
XNOR Tree Test Mode ...............................................................46
Register Tables .................................................................................47
Outline Dimensions........................................................................76
Ordering Guide ...........................................................................76
Additional ADC Functions for Temperature Measurement .23
REVISION HISTORY
7/07—Revision 0: Initial Version
Rev. 0 | Page 3 of 76
ADT7490
SPECIFICATIONS
TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted. All voltages are measured with respect to GND, unless otherwise specified.
Typical voltages are TA = 25°C and represent a parametric norm. Logic inputs accept input high voltages up to VMAX, even when the device
is operating down to VMIN. Timing specifications are tested at logic levels of VIL = 0.8 V for a falling edge, and VIH = 2.0 V for a rising edge.
Table 1.
Parameter
POWER SUPPLY
Supply Voltage
Supply Current, ICC
TEMPERATURE-TO-DIGITAL CONVERTER
Local Sensor Accuracy
Min
Typ
Max
Unit
Test Conditions/Comments
3.0
3.3
1.5
3.6
5
V
mA
Interface inactive, ADC active
±0.5
±1.5
±2.5
1.5
°C
°C
°C
°C
°C
°C
μA
μA
μΑ
kΩ
±2
±1.5
%
%
±1
LSB
%/V
13
14
14
43
193
ms
ms
ms
ms
ms
ms
kΩ
kΩ
Averaging enabled, all channels excluding VTT2
Averaging enabled
Averaging enabled
Averaging enabled
Averaging enabled
Averaging disabled
For +12VIN channel
For all other channels
±10
±14
65,535
%
%
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
RPM
RPM
RPM
RPM
Fan count = 0xBFFF
Fan count = 0x3FFF
Fan count = 0x0438
Fan count = 0x021C
mA
V
μA
IOUT = −8.0 mA
VOUT = VCC
Resolution
Remote Diode Sensor Accuracy
0.25
±0.5
Resolution
Remote Sensor Source Current
0.25
12
72
192
Series Resistance Cancellation1
ANALOG-TO-DIGITAL CONVERTER
(INCLUDING MUX AND ATTENTUATORS)
Total Unadjusted Error (TUE)
Differential Nonlinearity (DNL)
Power Supply Sensitivity
Conversion Times 1
Voltage Inputs
VTT Voltage Input2
Local Temperature
Remote Temperature
Total Monitoring Cycle Time
Input Resistance
±0.1
150
70
11
12
12
38
169
19
200
100
FAN RPM-TO-DIGITAL CONVERTER
Accuracy
Full-Scale Count
Nominal Input RPM
OPEN-DRAIN DIGITAL OUTPUTS,
PWM1 TO PWM3, XTO
Current Sink, IOL
Output Low Voltage, VOL
High Level Output Current, IOH
±1.5
±2.5
109
329
5000
10,000
0.1
8.0
0.4
20
Rev. 0 | Page 4 of 76
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
0°C ≤ TA ≤ 85°C
−40°C ≤ TA ≤ +125°C
Low level
Mid level
High level
The ADT7490 cancels up to 2 kΩ in series
with the remote thermal sensor
For all channels: −40°C ≤ TA ≤ +125°C
For all other channels except +12VIN:
0°C ≤ TA ≤ +125°C
8 bits
ADT7490
Parameter
OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA)
Output Low Voltage, VOL
High Level Output Current, IOH
SMBus DIGITAL INPUTS (SCL, SDA)
Input High Voltage, VIH
Input Low Voltage, VIL
Hysteresis
Digital I/O (PECI PIN)1
VTT, Supply Voltage
Input High Voltage , VIH
Input Low Voltage, VIL
Hysteresis 1
High Level Output Source Current, ISOURCE
Low Level Output Sink Current, ISINK
Signal Noise Immunity, VNOISE
DIGITAL INPUT LOGIC LEVELS (TACH1 to
TACH3)
Input High Voltage, VIH
Min
Typ
Max
Unit
Test Conditions/Comments
0.1
0.4
1.0
V
μA
IOUT = −4.0 mA
VOUT = VCC
2.0
V
V
mV
V
0.4
500
0.95
1.26
0.55 × VTT 2
0.5 × VTT2
0.1 × VTT2
6
1.0
0.5
300
2.0
V
V
5.5
Input Low Voltage, VIL
0.8
2
0.75 × VCC
0.4
±1
±1
5
Minimum input voltage
V
V
μA
μA
pF
VIN = VCC
VIN = 0
See Figure 2
10
400
50
4.7
4.7
4.0
kHz
ns
μs
μs
μs
ns
μs
ns
ms
50
1000
300
250
15
35
Can be optionally disabled
Guaranteed by design, not production tested.
VTT is the voltage input on Pin 8. The VTT voltage is determined by the processor installed on the system.
tLOW
tR
tF
tHD;STA
SCL
tHD;STA
SDA
tHD;DAT
tHIGH
tBUF
P
tSU;STA
tSU;DAT
S
S
Figure 2. SMBus Timing Diagram
Rev. 0 | Page 5 of 76
tSU;STO
P
06789-002
1
0.5
Hysteresis between input switching levels
VOH = 0.75 × VTT
VOL = 0.25 × VTT
Noise glitches from 10 MHz to 100 MHz,
width up to 50 ns
Maximum input voltage
V
V
V p-p
−0.3
Hysteresis
DIGITAL INPUT LOGIC LEVELS (THERM)
Input High Voltage, VIH
Input Low Voltage, VIL
DIGITAL INPUT CURRENT
Input High Current, IIH
Input Low Current, IIL
Input Capacitance, CIN
SERIAL BUS TIMING1
Clock Frequency, fSCLK
Glitch Immunity, tSW
Bus Free Time, tBUF
SCL Low Time, tLOW
SCL High Time, tHIGH
SCL, SDA Rise Time, tR
SCL, SDA Fall Time, tF
Data Setup Time, tSU;DAT
Detect Clock Low Timeout, tTIMEOUT
V
V
mV
mA
mA
mV p-p
ADT7490
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
Positive Supply Voltage (VCC)
Maximum Voltage on +12VIN Pin
Maximum Voltage on +5VIN Pin
Maximum Voltage on All Open-Drain Outputs
Maximum Voltage on TACHx/PWMx Pins
Voltage on Remaining Input or Output Pins
Input Current at Any Pin
Package Input Current
Maximum Junction Temperature (TJ max)
Storage Temperature Range
Lead Temperature, Soldering
IR Reflow Peak Temperature
Pb-Free Peak Temperature
Lead Temperature (Soldering, 10 sec)
ESD Rating
HBM
FICDM
Rating
3.6 V
16 V
6.25 V
3.6 V
+5.5 V
−0.3 V to +4.2 V
±5 mA
±20 mA
150°C
−65°C to +150°C
THERMAL CHARACTERISTICS
24-lead QSOP package:
Table 3. Thermal Resistance
Package Type
θJA
θJC
ESD CAUTION
220°C
260°C
300°C
2 kV
0.5 kV
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Rev. 0 | Page 6 of 76
θJA
122
31.25
Unit
°C/W
°C/W
ADT7490
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
SDA 1
24 PWM1/XTO
SCL 2
23 VCCP
GND 3
22 +2.5VIN/THERM
VCC 4
GPIO2 6
PECI 7
21 +12VIN
ADT7490
20 +5VIN
19 IMON
TOP VIEW
(Not to Scale) 18 D1+
VTT 8
17 D1–
TACH3 9
16 D2+
PWM2/SMBALERT 10
15 D2–
TACH1 11
14 TACH4/THERM/SMBALERT/ADDR SELECT
TACH2 12
13 PWM3/ADDREN
06789-003
GPIO1 5
Figure 3.Pin Configuration
Table 4. Pin Function Descriptions
Pin No.
1
2
3
4
5
Mnemonic
SDA
SCL
GND
VCC
GPIO1
Type
Digital I/O
Digital Input
Ground
Power Supply
Digital Input/Output
6
GPIO2
Digital Input/Output
7
PECI
Digital Input
8
VTT
Analog Input
9
10
TACH3
PWM2/
Digital Input
Digital Output
SMBALERT
11
12
13
TACH1
TACH2
PWM3/
Digital Input
Digital Input
Digital Output
ADDREN
14
TACH4/
THERM/
Digital Input/Output
SMBALERT/
15
16
17
18
19
ADDR SELECT
D2−
D2+
D1−
D1+
IMON
Analog Input
Analog Input
Analog Input
Analog Input
Analog Input
Description
SMBus Bidirectional Serial Data. Open drain, requires SMBus pull-up.
SMBus Serial Clock Input. Open drain, requires SMBus pull-up.
Ground Pin.
3.3 V ± 10%.
General-Purpose Open-Drain Digital Input/Output. Frequently used for switching
loadline resistors into VR loadline circuitry or for switching LEDs using external FETs.
General-Purpose Open-Drain Digital Input/Output. Frequently used for switching
loadline resistors into VR loadline circuitry or for switching LEDs using external FETs.
PECI Input to Report CPU Thermal Information. PECI voltage level is referenced on the
VTT input
Voltage Reference for PECI. This is the supply voltage for the PECI interface and must be
present to measure temperature over the PECI interface. This voltage is also monitored
and presented in register 0x1E.
Fan Tachometer Input to Measure Speed of FAN 3 (Open-Drain Digital Input).
Pulse Width Modulated Output to Control FAN 2 Speed. Open drain requires 10 kΩ
typical pull-up.
Digital Output (Open Drain). This pin can be reconfigured as an SMBALERT interrupt
output to signal out-of-limit conditions.
Fan Tachometer Input to Measure Speed Of Fan 1 (Open-Drain Digital Input.).
Fan Tachometer Input To Measure Speed Of Fan 2 (Open-Drain Digital Input.).
Pulse Width Modulated Output to Control Fan 3 Speed. Open drain requires 10kΩ
typical pull-up.
If pulled low on power-up, the ADT7490 enters address select mode, and the state of
Pin 14 (ADDR SELECT) determines the ADT7490’s slave address.
Fan Tachometer Input to Measure Speed of Fan 4 (Open-Drain Digital Input).
May be reconfigured as a bidirectional THERM pin. Can be connected to PROCHOT
output of processor, to time and monitor PROCHOT assertions. Can be used as an
output to signal overtemperature conditions or for clock modulation purposes.
Active Low Digital Output. The SMBALERT Pin is used to signal out-of-limit comparisons
of temperature, voltage, and fan speed. This is compatible with SMBus alert.
Can also be used at device power-up to assign SMBus address.
Negative Connection for Remote Temperature Sensor 2.
Positive Connection to Remote Temperature Sensor 2.
Negative Connection for Remote Temperature Sensor 1.
Positive Connection to Remote Temperature Sensor 1.
Monitors Current Output of Analog Devices ADP319x family of VRD10/VRD11
controllers.
Rev. 0 | Page 7 of 76
ADT7490
Pin No.
20
21
22
Mnemonic
+5VIN
+12VIN
+2.5VIN/
THERM
Type
Analog Input
Analog Input
Analog Input
23
VCCP
Analog Input
24
PWM1/
Digital Output
XTO
Description
Monitors 5 V Supply Using Internal Resistor Dividers.
Monitors 12 V Supply Using Internal Resistor Dividers.
Monitors 2.5 V Supply Using Internal Resistor Dividers.
Alternatively, this pin can be reconfigured as a bidirectional THERM pin. Can be
connected to PROCHOT output of processor to time and monitor PROCHOT assertions.
Can be used as an output to signal overtemperature conditions or for clock modulation
purposes.
Monitors CPU VCC Voltage (to maximum of 3.0 V). All voltage inputs can have their
resistor dividers removed allowing for full-scale input of 2.25 V of ADC channel.
Pulse Width Modulated Output to Control FAN 1 Speed. Open drain requires 10 kΩ
typical pull-up.
Also functions as the output for the XNOR tree test enable mode.
Table 5. Comparison of ADT7490 and ADT7476A Configurations
Pin Number
ADT7490
ADT7476A
1
SDA
SDA
2
SCL
SCL
3
GND
GND
4
VCC
VCC
5
GPIO1
VID0/GPIO0
6
GPIO2
VID1/GPIO1
7
PECI
VID2/GPIO2
8
VTT
VID3/GPIO3
9
TACH3
TACH3
10
PWM2/SMBALERT
PWM2/SMBALERT
11
TACH1
TACH1
12
TACH2
TACH2
13
PWM3/ADDREN
PWM3/ADDREN
14
TACH4/THERM/SMBALERT/ADDR SELECT
TACH4/THERM/SMBALERT/GPIO6/ADDR SELECT
15
D2−
D2−
16
D2+
D2+
17
D1−
D1−
18
D1+
D1+
19
IMON
VID4/GPIO4
20
+5VIN
+5VIN
21
+12VIN
+12VIN/VID5
22
+2.5VIN/THERM
+2.5VIN/THERM
23
VCCP
VCCP
24
PWM1/XTO
PWM1/XTO
Rev. 0 | Page 8 of 76
ADT7490
3.0
4.7
DEV 1
DEV 2
DEV 3
DEV 4
DEV 5
DEV 6
DEV 7
DEV 8
DEV 9
DEV 10
DEV 11
DEV 12
DEV 13
DEV 14
DEV 15
DEV 16
DEV 17
DEV 18
DEV 19
DEV 20
DEV 21
DEV 22
DEV 23
DEV 24
DEV 25
DEV 26
DEV 27
DEV 28
DEV 29
DEV 30
DEV 31
DEV 32
MEAN
LOW SPEC
HIGH SPEC
2.5
DEV 1
DEV 3
4.1
DEV 2
3.9
3.7
2.0
1.5
1.0
0.5
0
–0.5
–1.0
–1.5
3.1
3.2
3.3
3.4
3.5
3.6
VDD (V)
–2.0
–40
06789-006
3.5
3.0
–20
0
25
40
60
70
85
100
125
TEMPERATURE (°C)
Figure 4. Supply Current vs. Supply Voltage
Figure 7. Remote 1 Temperature Sensor Error
4.24
3.0
DEV 1
DEV 2
DEV 3
DEV 4
DEV 5
DEV 6
DEV 7
DEV 8
DEV 9
DEV 10
DEV 11
DEV 12
DEV 13
DEV 14
DEV 15
DEV 16
DEV 17
DEV 18
DEV 19
DEV 20
DEV 21
DEV 22
DEV 23
DEV 24
DEV 25
DEV 26
DEV 27
DEV 28
DEV 29
DEV 30
DEV 31
DEV 32
MEAN
LOW SPEC
HIGH SPEC
2.5
4.22
TEMPERATURE ERROR (°C)
NORMAL IDD (mA)
DEV 2
4.20
4.18
DEV 1
4.16
4.14
DEV 3
2.0
1.5
1.0
0.5
0
–0.5
–1.0
–1.5
–20
0
20
40
60
80
100
120
TEMPERATURE (°C)
–2.0
–40
06789-007
4.12
–40
–20
1.5
1.0
0.5
0
–0.5
–1.0
40
60
70
85
100
TEMPERATURE (°C)
70
85
100
125
125
EXTERNAL 2
EXTERNAL 1
100
LOCAL
80
60
40
20
0
06789-072
2.0
25
60
120
MEASURED TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
2.5
140
06789-008
DEV 1
DEV 2
DEV 3
DEV 4
DEV 5
DEV 6
DEV 7
DEV 8
DEV 9
DEV 10
DEV 11
DEV 12
DEV 13
DEV 14
DEV 15
DEV 16
DEV 17
DEV 18
DEV 19
DEV 20
DEV 21
DEV 22
DEV 23
DEV 24
DEV 25
DEV 26
DEV 27
DEV 28
DEV 29
DEV 30
DEV 31
DEV 32
MEAN
LOW SPEC
HIGH SPEC
0
40
Figure 8. Remote 2 Temperature Sensor Error
3.0
–20
25
TEMPERATURE (°C)
Figure 5. Supply Current vs. Temperature
–1.5
–40
0
0
10
20
30
40
50
TIME (s)
Figure 9. ADT7490 Response to Thermal Shock
Figure 6. Local Temperature Sensor Error
Rev. 0 | Page 9 of 76
60
06789-010
NORMAL IDD (mA)
4.3
TEMPERATURE ERROR (°C)
4.5
06789-009
TYPICAL PERFORMANCE CHARACTERISTICS
ADT7490
20
8
DEV 1
15
TEMPERATURE ERROR (°C)
TEMPERATURE ERROR (°C)
6
4
2
0
DEV 3
–2
–4
10
100mV
60mV
5
40mV
0
DEV 2
–5
0
200
400
600
800
1000
1200
1400
1600
SERIES RESISTANCE (Ω)
–10
06789-071
400
500
600
140
3.0
TEMPERATURE ERROR (°C)
2.5
2.0
1.5
1.0
0.5
0
120
100
80
60
100mV
40
60mV
20
0
–0.5
40mV
100
200
300
400
500
600
POWER SUPPLY NOISE FREQUENCY (MHz)
–20
06789-011
0
0
100
200
300
400
500
600
DIFFERENTIAL MODE NOISE FREQUENCY (MHz)
Figure 11. Local Temperature Error vs. Power Supply Noise Frequency
06789-014
TEMPERATURE ERROR (°C)
300
160
100mV
250mV
3.5
Figure 14. Temperature Error vs. Differential Mode Noise Frequency
0.6
5
100mV
250mV
0.4
0
DEV 3
0.2
TEMPERATURE ERROR (°C)
TEMPERATURE ERROR (°C)
200
Figure 13. Temperature Error vs. Common-Mode Noise Frequency
4.0
0
–0.2
–0.4
–0.6
–0.8
–5
DEV 2
–10
–15
DEV 1
–20
–25
–30
0
100
200
300
400
500
POWER SUPPLY NOISE FREQUENCY (MHz)
600
06789-012
–1.0
–1.2
100
COMMON-MODE NOISE FREQUENCY (MHz)
Figure 10. Temperature Error vs. Series Resistance
–1.0
0
Figure 12. Remote Temperature Error vs. Power Supply Noise Frequency
Rev. 0 | Page 10 of 76
–35
0
2
4
6
8
10
12
14
16
18
20
22
CAPACITANCE (nF)
Figure 15. Temperature Error vs. Capacitance Between D+ and D−
06789-015
–8
06789-013
–6
ADT7490
1.5
8
DEV 2
1.0
ACCURACY (%)
0
–0.5
–1.0
DEV 1
2
DEV 2
0
–2
–4
–1.5
3.1
3.2
3.3
3.4
3.5
VDD (V)
3.6
Figure 16. TACH Accuracy vs. Power Supply
–8
–40
–20
0
20
40
60
80
TEMPERATURE (°C)
Figure 17. TACH Accuracy vs. Temperature
Rev. 0 | Page 11 of 76
100
120
06789-070
–6
06789-069
–2.0
3.0
DEV 3
4
DEV 3
0.5
ACCURACY (%)
6
DEV 1
ADT7490
THEORY OF OPERATION
The ADT7490 is a complete thermal monitor and multiple fan
controller for any system requiring thermal monitoring and
cooling. The device communicates with the system via a serial
system management bus. The serial bus controller has a serial
data line for reading and writing addresses and data (Pin 1),
and an input line for the serial clock (Pin 2). All control and
programming functions for the ADT7490 are performed over
the serial bus. In addition, Pin 14 can be reconfigured as an
SMBALERT output to signal out-of-limit conditions.
FEATURE COMPARISONS BETWEEN THE ADT7490
AND ADT7476A
The ADT7490 is pin and register map compatible with the
ADT7476A. The new or additional features are detailed in the
following sections.
PECI Input
Table 6. PECI Data Format
x
MSB Lower Nibble
x
x
x
x
Integer value (0°C to 127°C)
x
The CPU thermal information from PECI can be used in the
existing automatic fan control algorithms. This temperature
reading remains relative to TCC activation temperature and the
associated AFC control parameters are programmed in relative
temperatures as opposed to absolute temperatures, and are in
the same format as detailed in Table 6. PECIMIN, TRANGE, and
TCONTROL are user defined.
PWMMAX
PECI = 0
PWMMIN
PWM = 0%
PECIMIN
(TMIN)
(TMAX)
TCONTROL
06789-005
TCC
TRANGE
Figure 18. Overview of Automatic Fan Speed Control
Using PECI Thermal Information
Dynamic TMIN Fan Control Mode
The automatic fan speed control incorporates a feature called
dynamic TMIN control. This intelligent fan control feature
reduces the design effort required to program the automatic fan
speed control loop and improves the system acoustics.
VTT Input
There are associated high and low limits for each PECI reading
that can be programmed. The limit values take the same format
as the PECI reading. Therefore, the programmed limits are not
absolute temperatures but a relative offset in degrees Celcius
from the TCC activation temperature. An out-of-limit event is
recorded as follows:
•
•
Fan Control Using PECI Information
PWM = 100%
CPU thermal information is provided through the PECI input.
The ADT7490 has PECI master capabilities and can read the
CPU thermal information through the PECI interface. Each
CPU address can have up to two PECI domains. The ADT7490
has the ability to record four PECI temperature readings
corresponding to the four PECI addresses of 0x30 to 0x33. The
hotter of the two domains at any given address is stored in the
PECI value registers. A PECI reading is a negative value, in
degrees Celsius, which represents the offset from the thermal
control circuit (TCC) activation temperature. PECI information
is not converted to absolute temperature reading. PECI information is in a 16-bit twos complement value; however, the
ADT7490 records the sign bit as well as the bits from 12:6 in
the 16-bit PECI payload. See the Platform Environment Control
Interface (PECI) Specification from Intel® for more details on the
PECI data format. The PECI format is represented in Table 6.
MSB Upper Nibble
S
x
Sign Bit
are replaced by PECI0 data and vice versa. This is a legacy mode
that allows the thermal data from CPU1 to be stored in the
same registers as in the ADT7476A. This reduces the software
changes in systems transitioning from CPUs with thermal
diodes to CPUs with a PECI interface. See the PECI Temperature
Measurement section for more details.
High Limit > comparison performed
Low Limit ≤ comparison performed
An out-of-limit event is recorded in the associated status
register and can be used to assert the SMBALERT pin.
Temperature Data REPLACE Mode
The REPLACE mode is configured by setting Bit 4 of Register
0x36. In this mode, the data in the existing Remote 1 registers
The VTT voltage is monitored on Pin 8. This voltage is also used
as the reference voltage for the PECI interface. The VTT voltage
must be connected to the ADT7490 in order for the PECI
interface to be operational.
IMON Monitoring
The IMON input on Pin 19 can be used to monitor the IMON
output of the Analog Devices ADP319x family of VR10/VR11
controllers. IMON is a voltage representation of the CPU current.
Using the IMON value and the measured VCCP value on Pin 23, the
CPU power consumption may be calculated. See the appropriate
Analog Devices flex mode data sheet for calculations. The IMON
information can be considered as an early indication of an
increase in CPU temperature.
Rev. 0 | Page 12 of 76
ADT7490
START-UP OPERATION
At startup, the ADT7490 turns the fans on to 100% PWM. This
allows the most robust operation at turn-on.
SERIAL BUS INTERFACE
Control of the ADT7490 is carried out using the serial system
management bus (SMBus). The ADT7490 is connected to this
bus as a slave device, under the control of a master controller.
The ADT7490 has a 7-bit serial bus address. When the device
is powered up with Pin 13 (PWM3/ADDREN) high, the
ADT7490 has a default SMBus address of 0101110 or 0x2E.
The read/write bit must be added to get the 8-bit address.
If more than one ADT7490 is to be used in a system, each
ADT7490 is placed in address select mode by strapping Pin 13
low on power-up. The logic state of Pin 14 then determines the
device’s SMBus address. The logic of these pins is sampled on
power-up.
The device address is sampled on power-up and latched on the
first valid SMBus transaction, more precisely on the low-tohigh transition at the beginning of the eighth SCL pulse, when
the serial bus address byte matches the selected slave address.
The selected slave address is chosen using the ADDREN/
ADDR SELECT pins. Any attempted changes in the address
have no effect after this.
Table 7. Hardwiring the ADT7490 SMBus Device Address
Pin 13 State
0
0
1
Pin 14 State
Low (10 kΩ to GND)
High (10 kΩ pull-up)
Don’t care
Address
0101100 (0x2C)
0101101 (0x2D)
0101110 (0x2E)
Data is sent over the serial bus in sequences of nine clock
pulses: eight bits of data followed by an acknowledge bit from
the slave device. Transitions on the data line must occur during
the low period of the clock signal and remain stable during the
high period, because a low-to-high transition when the clock is
high may be interpreted as a stop signal. The number of data
bytes that can be transmitted over the serial bus in a single read
or write operation is limited only by what the master and slave
devices can handle.
ninth clock pulse; this is known as no acknowledge. The master
takes the data line low during the low period before the 10th
clock pulse, and then high during the 10th clock pulse to assert
a stop condition.
Any number of bytes of data can be transferred over the serial
bus in one operation, but it is not possible to mix read and write
in one operation because the type of operation is determined at
the beginning and cannot subsequently be changed without
starting a new operation.
In the ADT7490, write operations contain either one or two
bytes, and read operations contain one byte. To write data to
one of the device data registers or read data from it, the address
pointer register must be set so that the correct data register is
addressed. Then data can be written into that register or read
from it. The first byte of a write operation always contains an
address that is stored in the address pointer register. If data is
to be written to the device, the write operation must contain a
second data byte that is written to the register selected by the
address pointer register.
This write operation is shown in Figure 19. The device address
is sent over the bus, and then R/W is set to 0. This is followed
by two data bytes. The first data byte is the address of the
internal data register to be written to, which is stored in the
address pointer register. The second data byte is the data to be
written to the internal data register.
When reading data from a register, there are two possibilities:
•
If the ADT7490 address pointer register value is unknown
or not the desired value, it must first be set to the correct
value before data can be read from the desired data register.
This is done by performing a write to the ADT7490 as
before, but only the data byte containing the register
address is sent because no data is written to the register.
This is shown in Figure 20.
A read operation is then performed consisting of the serial
bus address, R/W bit set to 1, followed by the data byte
read from the data register. This is shown in Figure 21.
•
When all data bytes have been read or written, stop conditions
are established. In write mode, the master pulls the data line
high during the 10th clock pulse to assert a stop condition. In
read mode, the master device overrides the acknowledge bit by
pulling the data line high during the low period before the
Rev. 0 | Page 13 of 76
If the address pointer register is known to be already at the
desired address, data can be read from the corresponding
data register without first writing to the address pointer
register, as shown in Figure 21.
ADT7490
1
9
9
1
SCL
0
SDA
1
0
1
1
0
1
D6
D7
R/W
START BY
MASTER
ACK. BY
ADT7490
FRAME 1
SERIAL BUS ADDRESS BYTE
D4
D5
D2
D3
D1
D0
ACK. BY
ADT7490
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
9
SCL (CONTINUED)
D4
D5
D6
D2
D3
D1
D0
ACK. BY
ADT7490
FRAME 3
DATA BYTE
STOP BY
MASTER
06789-016
D7
SDA (CONTINUED)
Figure 19. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
9
9
1
SCL
0
1
START BY
MASTER
0
1
1
1
0
D6
D7
R/W
ACK. BY
ADT7490
FRAME 1
SERIAL BUS ADDRESS BYTE
D4
D5
D3
D2
D1
D0
ACK. BY
ADT7490
FRAME 2
ADDRESS POINTER REGISTER BYTE
STOP BY
MASTER
06789-017
SDA
Figure 20. Writing to the Address Pointer Register Only
1
9
9
1
SCL
START BY
MASTER
0
1
0
1
1
1
0
R/W
D6
D7
ACK. BY
ADT7490
FRAME 1
SERIAL BUS ADDRESS BYTE
D5
D4
D3
D2
D1
FRAME 2
DATA BYTE FROM ADT7490
D0
NO ACK. BY STOP BY
MASTER
MASTER
06789-018
SDA
Figure 21. Reading Data from a Previously Selected Register
It is possible to read a data byte from a data register without
first writing to the address pointer register if the address pointer
register is already at the correct value. However, it is not possible to write data to a register without writing to the address
pointer register because the first data byte of a write is always
written to the address pointer register.
In addition to supporting the send byte and receive byte
protocols, the ADT7490 also supports the read byte protocol
(see System Management Bus Specifications Rev. 2 for more
information; this document is available from the SMBus
organization).
If several read or write operations must be performed in succession, the master can send a repeat start condition instead of a
stop condition to begin a new operation.
WRITE OPERATIONS
The SMBus specification defines several protocols for different
types of read and write operations. The ones used in the
ADT7490 are discussed here. The following abbreviations are
used in the diagrams:
•
•
•
•
•
•
S: Start
P: Stop
R: Read
W: Write
A: Acknowledge
A: No acknowledge
The ADT7490 uses the following SMBus write protocols.
Rev. 0 | Page 14 of 76
ADT7490
Send Byte
READ OPERATIONS
In this operation, the master device sends a single command
byte to a slave device, as follows:
The ADT7490 uses the following SMBus read protocols.
1.
2.
This operation is useful when repeatedly reading a single
register. The register address must be previously set up. In this
operation, the master device receives a single byte from a slave
device, as follows:
1
2
3
SLAVE
S
W A
ADDRESS
4
5 6
REGISTER
ADDRESS
A P
06789-019
For the ADT7490, the send byte protocol is used to write a
register address to RAM for a subsequent single-byte read from
the same address. This operation is illustrated in Figure 22.
Figure 22. Setting a Register Address for Subsequent Read
If the master is required to read data from the register immediately after setting up the address, it can assert a repeat start
condition immediately after the final ACK and carry out a
single-byte read without asserting an intermediate stop
condition.
Receive Byte
1.
2.
3.
4.
5.
6.
In the ADT7490, the receive byte protocol is used to read a
single byte of data from a register whose address has previously
been set by a send byte or write byte operation. This operation
is illustrated in Figure 24.
1
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
write bit (low).
The addressed slave device asserts ACK on SDA.
The master sends a command code.
The slave asserts ACK on SDA.
The master sends a data byte.
The slave asserts ACK on SDA.
The master asserts a stop condition on SDA, and the
transaction ends.
The byte write operation is illustrated in Figure 23.
4
5 6
DATA
A P
2
3
SLAVE
S ADDRESS W A
4
5
6
REGISTER
ADDRESS
A
DATA
7
Figure 23. Single Byte Write to a Register
Alert response address (ARA) is a feature of SMBus devices that
allows an interrupting device to identify itself to the host when
multiple devices exist on the same bus.
The SMBALERT output can be used as either an interrupt
output or an SMBALERT. One or more outputs can be
connected to a common SMBALERT line connected to the
master. If a device’s SMBALERT line goes low, the following
events occur:
1.
2.
3.
8
A P
Alert Response Address
06789-020
1
3
Figure 24. Single-Byte Read from a Register
In this operation, the master device sends a command byte and
one data byte to the slave device, as follows:
3.
4.
5.
6.
7.
8.
2
SLAVE
S ADDRESS R A
Write Byte
1.
2.
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
read bit (high).
The addressed slave device asserts ACK on SDA.
The master receives a data byte.
The master asserts NO ACK on SDA.
The master asserts a stop condition on SDA, and the
transaction ends.
06789-021
3.
4.
5.
6.
The master device asserts a start condition on SDA.
The master sends the 7-bit slave address followed by the
write bit (low).
The addressed slave device asserts ACK on SDA.
The master sends a command code.
The slave asserts ACK on SDA.
The master asserts a stop condition on SDA and the
transaction ends.
4.
5.
Rev. 0 | Page 15 of 76
SMBALERT is pulled low.
The master initiates a read operation and sends the alert
response address (ARA = 0001 100). This is a general call
address that must not be used as a specific device address.
The device whose SMBALERT output is low responds to
the alert response address, and the master reads its device
address. The address of the device is now known and can
be interrogated in the usual way.
If more than one device’s SMBALERT output is low, the
one with the lowest device address has priority in accordance with normal SMBus arbitration.
Once the ADT7490 has responded to the alert response
address, the master must read the status registers, and the
SMBALERT is cleared only if the error condition is gone.
ADT7490
SMBus TIMEOUT
12V IN
The ADT7490 includes an SMBus timeout feature. If there is no
SMBus activity for 35 ms, the ADT7490 assumes the bus is
locked and releases the bus. This prevents the device from
locking or holding the SMBus expecting data. Some SMBus
controllers cannot work with the SMBus timeout feature, so it
can be disabled.
5VIN
3.3VIN
120kΩ
2.5VIN
Bit 4 (TODIS) = 1, SMBus timeout disabled.
30pF
47kΩ
30pF
71kΩ
30pF
94kΩ
30pF
93kΩ
68kΩ
Configuration Register 7 (Register 0x11)
Bit 4 (TODIS) = 0, SMBus timeout enabled (default).
20kΩ
45kΩ
MUX
VOLTAGE MEASUREMENT INPUT
VCCP
The ADT7490 has six external voltage measurement channels.
It can also measure its own supply voltage, VCC.
Analog-to-Digital Converter
52.5kΩ
IMON
VTT
35pF
45kΩ
94kΩ
30pF
45kΩ
30pF
45kΩ
06789-025
Pin 20 to Pin 23 can measure 5 V, 12 V, and 2.5 V supplies, and
the processor core voltage VCCP (0 V to 3 V input). The 2.5 V
input can be used to monitor a chipset supply voltage in
computer systems. The VCC supply voltage measurement is
carried out through the VCC pin (Pin 4). Pin 8 measures the
processor’s VTT voltage and is the dedicated reference voltage for
the PECI circuitry. The IMON input on Pin 19 can be used to
monitor the IMON output of the Analog Devices ADP319x family
of VR10/VR11 controllers. IMON is a voltage representation of
the CPU current.
17.5kΩ
Figure 25. Analog Inputs structure
Voltage Limit Registers
Associated with each voltage measurement channel is a high
and low limit register. Exceeding the programmed high or low
limit causes the appropriate status bit to be set. Exceeding either
limit can also generate SMBALERT interrupts.
All analog inputs are multiplexed into the on-chip, successiveapproximation, analog-to-digital converter. This ADC has a
resolution of 10 bits. The basic input range is 0 V to 2.25 V,
but the inputs have built-in attenuators to allow measurement
of 2.5 V, 3.3 V, 5 V, 12 V, and the processor core voltage VCCP
without any external components. To allow the tolerance of
these supply voltages, the ADC produces an output of ¾ full
scale (768 dec or 0x300 hex) for the nominal input voltage, and
therefore, has adequate headroom to cope with overvoltages.
Register 0x87, IMON High Limit = 0xFF default
Input Circuitry
Register 0x45, +2.5VIN High Limit = 0xFF default
The internal structure for the analog inputs is shown in Figure 25.
The input circuit consists of an input protection diode, an
attenuator, plus a capacitor to form a first-order low-pass filter
that gives input immunity to high frequency noise.
Register 0x46, VCCP Low Limit = 0x00 default
Voltage Measurement Registers
Register 0x1D, IMON Reading = 0x00 default
Register 0x1E, VTT Reading = 0x00 default
Register 0x20, +2.5VIN Reading = 0x00 default
Register 0x21, VCCP Reading = 0x00 default
Register 0x22, VCC Reading = 0x00 default
Register 0x23, +5VIN Reading = 0x00 default
Register 0x85, IMON Low Limit = 0x00 default
Register 0x84, VTT Low Limit = 0x00 default
Register 0x86, VTT High Limit = 0xFF default
Register 0x44, +2.5VIN Low Limit = 0x00 default
Register 0x47, VCCP High Limit = 0xFF default
Register 0x48, VCC Low Limit = 0x00 default
Register 0x49, VCC High Limit = 0xFF default
Register 0x4A, +5VIN Low Limit = 0x00 default
Register 0x4B, +5VIN High Limit = 0xFF default
Register 0x4C, +12VIN Low Limit = 0x00 default
Register 0x4D, +12VIN High Limit = 0xFF default
When the ADC is running, it samples and converts a voltage
input in 0.7 ms and averages 16 conversions to reduce noise;
a measurement takes nominally 11 ms.
Register 0x24, +12VIN Reading = 0x00 default
Rev. 0 | Page 16 of 76
ADT7490
Extended Resolution Registers
Bypass All Voltage Input Attenuators
Voltage measurements can be made with higher accuracy
using the extended resolution registers (0x1F, 0x76, and 0x77).
Whenever the extended resolution registers are read, the
corresponding data in the voltage measurement registers (0x1D,
0x1E, and 0x20 to 0x24) is locked until their data is read. That
is, if extended resolution is required, the extended resolution
register must be read first, immediately followed by the appropriate
voltage measurement register.
Setting Bit 5 of Configuration Register 2 (Register 0x73)
removes the attenuation circuitry from the 2.5 VIN, VCCP,
VCC, 5 VIN, and 12 VIN inputs. This allows the user to directly
connect external sensors or rescale the analog voltage measurement inputs for other applications. The input range of the ADC
without the attenuators is 0 V to 2.25 V.
ADDITIONAL ADC FUNCTIONS FOR VOLTAGE
MEASUREMENTS
A number of other functions are available on the ADT7490
to offer the system designer increased flexibility. The functions
described in the following sections are enabled by setting the
appropriate bit in Configuration Register 2.
Bypass Individual Voltage Input Attenuators
Bits [7:4] of Configuration Register 4 (0x7D) can be used
to bypass individual voltage channel attenuators.
Table 9. Bypassing Individual Voltage Input Attenuators
Bit 4 (AVG) = 1, averaging off.
Configuration Register 4 (0x7D)
Bit No.
Channel Attenuated
4
Bypass +2.5VIN attenuator
5
Bypass VCCP attenuator
6
Bypass +5VIN attenuator
7
Bypass +12VIN attenuator
Bit 5 (ATTN) = 1, bypass input attenuators.
Single-Channel ADC Conversion
Bit 6 (CONV) = 1, single-channel convert mode.
While single-channel mode is intended as a test mode that
can be used to increase sampling times for a specific channel,
therefore helping to analyze that channel’s performance in
greater detail, it can also have other applications.
Configuration Register 2 (Register 0x73)
Turn-Off Averaging
For each voltage/temperature measurement read from a value
register, 16 readings have actually been made internally and
the results averaged before being placed into the value register. When faster conversions are needed, setting Bit 4 (AVG)
of Configuration Register 2 (0x73) turns averaging off. This
effectively gives a reading that is 16 times faster, but the reading
can be noisier. The default round-robin cycle time takes 146.5 ms.
Table 8. Conversion Time with Averaging Disabled
Channel
Voltage Channels
Remote Temperature 1
Remote Temperature 2
Local Temperature
Setting Bit 6 of Configuration Register 2 (0x73) places the
ADT7490 into single-channel ADC conversion mode. In this
mode, the ADT7490 can read a single voltage channel only.
The selected voltage input is read every 0.7 ms. The appropriate
ADC channel is selected by writing to Bits [7:4] of the TACH1
minimum high byte register (0x55).
Table 10. Programming Single-Channel ADC Mode
Measurement Time (ms)
0.7
7
7
1.3
When Bit 7 (ExtraSlow) of Configuration Register 6 (0x10) is
set, the default round-robin cycle time increases to 240 ms.
Bits [7:4] Register 0x55
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1
Channel Selected 1
+2.5VIN
VCCP
VCC
+5VIN
+12VIN
Remote 1 temperature
Local temperature
Remote 2 temperature
VTT
IMON
In the process of configuring single-channel ADC conversion mode, the
TACH1 minimum high byte is also changed, possibly trading off TACH1
minimum high byte functionality with single-channel mode functionality.
Rev. 0 | Page 17 of 76
ADT7490
Table 11. 10-Bit ADC Output Code vs. VIN
+12VIN
<0.0156
0.0156 to
0.0312
0.0312 to
0.0469
0.0469 to
0.0625
0.0625 to
0.0781
0.0781 to
0.0937
0.0937 to
0.1093
0.1093 to
0.1250
0.1250 to
0.14060
…
4.0000 to
4.0156
…
8.0000 to
8.0156
…
12.0000 to
12.0156
…
15.8281 to
15.8437
15.8437 to
15.8593
15.8593 to
15.8750
15.8750 to
15.8906
15.8906 to
15.9062
15.9062 to
15.9218
15.9218 to
15.9375
15.9375 to
15.9531
15.9531 to
15.9687
15.9687 to
15.9843
>15.9843
+5VIN
<0.0065
0.0065 to
0.0130
0.0130 to
0.0195
0.0195 to
0.0260
0.0260 to
0.0325
0.0325 to
0.0390
0.0390 to
0.0455
0.0455 to
0.0521
0.0521 to
0.0586
Input Voltage
VCC (3.3 VIN)
+2.5VIN
<0.0042
<0.0032
0.0042 to
0.0032 to
0.0085
0.0065
0.0085 to
0.0065 to
0.0128
0.0097
0.0128 to
0.0097 to
0.0171
0.0130
0.0171 to
0.0130 to
0.0214
0.0162
0.0214 to
0.0162 to
0.0257
0.0195
0.0257 to
0.0195 to
0.0300
0.0227
0.0300 to
0.0227 to
0.0343
0.0260
0.0343 to
0.0260 to
0.0386
0.0292
VCCP
<0.00293
0.0293 to
0.0058
0.0058 to
0.0087
0.0087 to
0.0117
0.0117 to
0.0146
0.0146 to
0.0175
0.0175 to
0.0205
0.0205 to
0.0234
0.0234 to
0.0263
VTT/IMON
<0.00220
0.00220 to
0.00440
0.00440 to
0,00660
0,00660 to
0.00881
0.00881 to
0.01100
0.01100 to
0.01320
0.01320 to
0.01541
0.01541 to
0.01761
0.01761 to
0.01981
Decimal
0
1
…
…
…
…
1.6675 to
1.6740
…
3.3300 to
3.3415
…
5.0025 to
5.0090
…
6.5983 to
6.6048
6.6048 to
6.6113
6.6113 to
6.6178
6.6178 to
6.6244
6.6244 to
6.6309
6.6309 to
6.6374
6.6374 to
6.4390
6.6439 to
6.6504
6.6504 to
6.6569
6.6569 to
6.6634
>6.6634
1.1000 to
1.1042
0.8325 to
0.8357
0.7500 to
0.7529
…
…
2.2000–2.2042
1.6650 to
1.6682
…
3.3000–3.3042
ADC Output
Binary (10 Bits)
00000000 00
00000000 01
2
00000000 10
3
00000000 11
4
00000001 00
5
00000001 01
6
00000001 10
7
00000001 11
8
00000010 00
…
…
…
0.5636 to
0.5658
256
(¼ scale)
01000000 00
…
…
…
…
1.5000 to
1.5029
1.1272 to
1.1294
512
(½ scale)
10000000 00
…
…
…
…
…
2.4975 to
2.5007
2.2500 to
2.2529
1.6809 to
1.6930
768
(¾ scale)
11000000 00
…
…
…
…
…
…
4.3527 to
4.3570
4.3570 to
4.3613
4.3613 to
4.3656
4.3656 to
4.3699
4.3699 to
4.3742
4.3742 to
4.3785
4.3785 to
4.3828
4.3828 to
4.3871
4.3871 to
4.3914
4.3914 to
4.3957
>4.3957
3.2942 to
3.2974
3.2974 to
3.3007
3.3007 to
3.3039
3.3039 to
3.3072
3.3072 to
3.3104
3.3104 to
3.3137
3.3137 to
3.3169
3.3169 to
3.3202
3.3202 to
3.3234
3.3234 to
3.3267
>3.3267
2.9677 to
2.9707
2.9707 to
2.9736
2.9736 to
2.9765
2.9765 to
2.9794
2.9794 to
2.9824
2.9824 to
2.9853
2.9853 to
2.9882
2.9882 to
2.9912
2.9912 to
2.9941
2.9941 to
2.9970
>2.9970
2.2301 to
2.2323
2.2323 to
2.2346
2.2346 to
2.2368
2.2368 to
2.23899
2,23899 to
2.2412
2.2412 to
2.2434
2.2434 to
2.2456
2.2456 to
2.2478
2.2478 to
2.25
2.25 to
2.2522
>2.2522
1013
11111101 01
1014
11111101 10
1015
11111101 11
1016
11111110 00
1017
11111110 01
1018
11111110 10
1019
11111110 11
1020
11111111 00
1021
11111111 01
1022
11111111 10
1023
11111111 11
Rev. 0 | Page 18 of 76
ADT7490
TEMPERATURE MEASUREMENT
PECI Offset Registers
The ADT7490 has four temperature measurement channels:
one local, two remote thermal diodes, and a PECI. The local
and thermal diode readings are analog temperature measurements, whereas PECI is a digital temperature reading.
Each PECI reading has a dedicated offset register to calibrate
the PECI measurement and account for errors in the temperature reading. The LSBs add a 1°C offset to the temperature
reading so that the 8-bit register effectively allows temperature
offsets of up to ±128°C with a resolution of 1°C.
PECI Temperature Measurement
The PECI interface is a dedicated thermal interface. The CPU
temperature measurement is carried out internally in the CPU.
This information is digitized and transferred to the ADT7490
via the PECI interface. The ADT7490 is a PECI host device and
therefore, polls the CPU for thermal information.
The PECI measurement differs from traditional thermal diode
temperature measurements in that the measurement is a relative
value instead of an absolute value. The PECI reading is a negative value that indicates how close the CPU temperature is from
the thermal throttling or TCC point of the CPU.
The ADT7490 records and uses the PECI measurement for fan
control in its relative format. Therefore, care must be taken in
programming the relevant limits and fan control parameters in
the PECI format. Refer to the PECI Input section and Table 6
for further PECI information.
PECI monitoring is enabled on the ADT7490 by setting the
PECI monitoring bit in Configuration Register 1 (Register 0x40,
Bit 4). The ADT7490 can measure the temperature of up to
four dual-core CPUs. The number of CPUs in the system that
provide PECI information is set in Bits [7:6] of Register 0x88.
Each CPU is distinguished by the PECI address. The number
of domains, or domain count, per CPU address must also be
programmed into the ADT7490. The ADT7490 reads the
temperature of both domains per CPU, however, only the PECI
value of the hottest domain is recorded in the PECI value
register.
Register 0x94, PECI0 Offset
Register 0x95, PECI1 Offset
Register 0x96, PECI2 Offset
Register 0x97, PECI3 Offset
PECI Data Smoothing
The PECI smoothing interval is programmed in PECI
Configuration Register 1 (0x36). Bits [2:0] of Register 0x36
set the duration over which the PECI data being read by the
ADT7490 is averaged. These bits set the duration over which
smoothing is carried out on the PECI data read. The refresh rate
in the PECI value registers is the same as the smoothing interval
programmed.
The smoothing interval is calculated using the following
formula:
Smoothing Interval = # reads × (t BIT × 67 × # CPU + t IDLE )
where:
#reads is the number of readings defined in Register 0x36,
Bits [2:0].
tBIT is the negotiated bit rate.
67 is the number of bits in each PECI reading.
#CPU is the number of CPUs providing PECI data (1 to 4).
tIDLE = 14 μs, the delay between consecutive reads.
For example,
#reads = 4096
tBIT = 1 μs (1 MHz speed)
#CPU = 1
Smoothing Interval = 331 ms = PECI reading refresh rate.
PECI0 domains: Register 0x36, Bit 3
PECI1 domains: Register 0x88, Bit 5
PECI2 domains: Register 0x88, Bit 4
PECI Error Codes
PECI3 domains: Register 0x88, Bit 3
PECI Reading Registers
Register 0x33, PECI0: PECI reading from CPU Address 0x30
Register 0x1A, PECI1: PECI reading from CPU Address 0x31
Register 0x1B, PECI2: PECI reading from CPU Address 0x32
Register 0x1C, PECI3: PECI reading from CPU Address 0x33
PECI Limit Registers
Each PECI measurement shares the same high and low limits.
Register 0x34, PECI Low Limit = 0x81 default
Register 0x35, PECI High Limit = 0x00 default
There are two different error conditions for PECI data, PECI
data errors, and PECI bus communications errors. Table 12
describes the two different error conditions. If the ADT7490
reads an error code (0x8000 to 0x8003) from the CPU over the
PECI interface, Bit 1 is set in Interrupt Status 3 register (0x43),
indicating a data error. The value of the error code is not
included in the PECI value averaging sum. This means that a
value of 0x00 is added to the PECI sum when an error code is
recorded. The error code is not reported in the appropriate
PECI value register. If an invalid FCS is recorded by the
ADT7490, Bit 2 is set in the Interrupt Status 3 register (0x43),
indicating a communications error. An alert is generated on the
SMBALERT pin when either or both of these status bits are
asserted.
Rev. 0 | Page 19 of 76
ADT7490
Table 12. PECI Error Indicators
PECI Data
0x8000 to
0x8003
Invalid FCS
Description
PECI data error
PECI communications
error
Action
Bit 1 of Register 0x43
is set to 1
Bit 2 of Register 0x43
is set to 1
Each PECI channel also has an associated status bit to indicate
if the PECI high or low limits have been exceeded. An alert is
generated on the SMBALERT pin when these status bits are
asserted.
Table 13. PECI Status Bits
Channel
PECI0
PECI1
PECI2
PECI3
Register
0x43
0x81
0x81
0x81
Bit
0
3
4
5
Temperature Data REPLACE Mode
The REPLACE mode is configured by setting Bit 4 of Register
0x36. In this mode, the data in the existing Remote 1 registers
are replaced by PECI0 data. This is a legacy mode that allows
the thermal data from CPU1 to be stored in the same registers
as in the ADT7476A. This reduces the software changes in
systems transitioning from CPUs with thermal diodes to CPUs
with a PECI interface. However, note that even though the
associated registers are swapped, the correct data format (PECI
vs. absolute temperature, see Table 6) must be written to and
interpreted from these registers.
Notes
In Table 14, registers listed under the Remote 1 Default column
are in absolute temperature format by default and are in PECI
format in REPLACE mode. Registers listed under the PECI0
Default column are in PECI format by default and in absolute
temperature format in REPLACE mode.
In REPLACE mode, the temperature zone controlling the
relevant PWM output are also swapped from Remote 1 to
PECI0. The swap of control only occurs if the default behavior
setting for Register 0x5C Bits [7:5], Register 0x5D Bits [7:5] or
Register 0x5E Bits [7:5] is 000.
Local Temperature Measurement
The ADT7490 contains an on-chip band gap temperature
sensor whose output is digitized by the on-chip 10-bit ADC.
The 8-bit MSB temperature data is stored in the local temperature register (Address 0x26). Because both positive and negative
temperatures can be measured, the temperature data is stored in
Offset 64 format or twos complement format, as shown in Table 15
and Table 16. Theoretically, the temperature sensor and ADC
can measure temperatures from −63°C to +127°C (or −63°C to
+191°C in the extended temperature range) with a resolution of
0.25°C. However, this exceeds the operating temperature range
of the device, so local temperature measurements outside the
ADT7490 operating temperature range are not possible.
Table 15. Twos Complement Temperature Data Format
Temperature
–128°C
–63°C
–50°C
–25°C
–10°C
0°C
10.25°C
25.5°C
50.75°C
75°C
100°C
125°C
127°C
1
Table 14. Replace Mode Temperature Registers
Register Name
Value Register
Low Limit
High Limit
TMIN
TRANGE
Enhanced Acoustics
Enhanced Acoustics
Enable
THERM TCONTROL
TMIN Hysteresis
Temperature offset
Operating Point for
Dynamic TMIN
1
Remote 1 Default
Reg. 0x25
Reg. 0x4E
Reg. 0x4F
Reg. 0x67
Reg. 0x5F, Bits [7:4]
Reg. 0x62, Bits [2:0]
Reg. 0x62, Bit 3
PECI0 Default
Reg. 0x33
Reg. 0x34
Reg. 0x35
Reg. 0x3B
Reg. 0x3C, Bits [7:4]
Reg. 0x3C, Bits [2:0]
Reg. 0x3C, Bit 3
Reg. 0x6A
Reg. 0x6D, Bits [7:4]
Reg. 0x6D, Bits [3:0]1
Reg. 0x70
Reg. 0x8B
Reg. 0x3D
Reg. 0x6E, Bits [3:0]
Reg. 0x6E, Bits [7:4]1
Reg. 0x94
Reg. 0x8A
In REPLACE mode, the Remote 2 and local temperature hysteresis values are
swapped.
Digital Output (10-Bit)1
1000 0000 00 (diode fault)
1100 0001 00
1100 1110 00
1110 0111 00
1111 0110 00
0000 0000 00
0000 1010 01
0001 1001 10
0011 0010 11
0100 1011 00
0110 0100 00
0111 1101 00
0111 1111 00
Bold numbers denote 2 LSBs of measurement in the Extended Resolution 2
register (Register 0x77) with 0.25°C resolution.
Table 16. Offset 64 Data Format
Temperature
–64°C
–63°C
–1°C
0°C
1°C
10°C
25°C
50°C
75°C
100°C
125°C
191°C
1
Digital Output (10-Bit)1
0000 0000 00 (diode fault)
0000 0001 00
0011 1111 00
0100 0000 00
0100 0001 00
0100 1010 00
0101 1001 00
0111 0010 00
1000 1001 00
1010 0100 00
1011 1101 00
1111 1111 00
Bold numbers denote 2 LSBs of measurement in the Extended Resolution 2
register (Register 0x77) with 0.25°C resolution.
Rev. 0 | Page 20 of 76
ADT7490
THERMAL DIODE TEMPERATURE MEASUREMENT
METHOD
A simple method of measuring temperature is to exploit the
negative temperature coefficient of a diode, measuring the baseemitter voltage (VBE) of a transistor operated at constant
current. Unfortunately, this technique requires calibration to
null out the effect of the absolute value of VBE, which varies
from device to device.
The technique used in the ADT7490 is to measure the change
in VBE when the device is operated at three different currents.
Previous devices have used only two operating currents, but the
use of a third current allows automatic cancellation of resistances in series with the external temperature sensor.
Figure 29 shows the input signal conditioning used to measure
the output of an external temperature sensor. This figure shows
the external sensor as a substrate transistor, but it could equally
be a discrete transistor, such as a 2N3904/2N3906.
If a discrete transistor is used, the collector is not grounded
and should be linked to the base. If a PNP transistor is used,
the base is connected to the D– input and the emitter to the D+
input. If an NPN transistor is used, the emitter is connected to
the D– input and the base to the D+ input. Figure 26 and Figure 27
show how to connect the ADT7490 to an NPN or PNP transistor for temperature measurement.
ADT7490
D+
D–
Figure 26. Measuring Temperature Using an NPN Transistor
ADT7490
D–
06789-028
D+
2N3906
PNP
The ADT7490 can measure the temperature of two remote
diode sensors or diode-connected transistors connected to
Pin 10 and Pin 11, or Pin 12 and Pin 13.
The forward voltage of a diode or diode-connected transistor
operated at a constant current exhibits a negative temperature
coefficient of about −2 mV/°C. Unfortunately, the absolute
value of VBE varies from device to device, and individual
calibration is required to null this out. Therefore, the technique
is unsuitable for mass production. The technique used in the
ADT7490 is to measure the change in VBE when the device is
operated at three different currents. This is given by
ΔVBE =
KT
× ln(N )
q
where:
K is the Boltzmann constant.
q is the charge on the carrier.
T is the absolute temperature in Kelvin.
N is the ratio of the two currents.
To measure ΔVBE, the operating current through the sensor is
switched among three related currents. N1 × I and N2 × I are
different multiples of the current I, as shown in Figure 28. The
currents through the temperature diode are switched between
I and N1 × I, giving ΔVBE1, and then between I and N2 × I,
giving ΔVBE2. The temperature can then be calculated using the
two ΔVBE measurements. This method can also cancel the effect
of any series resistance on the temperature measurement.
The resulting ΔVBE waveforms are passed through a 65 kHz
low-pass filter to remove noise and then to a chopper-stabilized
amplifier. This amplifies and rectifies the waveform to produce
a dc voltage proportional to ΔVBE. The ADC digitizes this
voltage, and a temperature measurement is produced. To reduce
the effects of noise, digital filtering is performed by averaging
the results of 16 measurement cycles.
06789-027
2N3904
NPN
Remote Temperature Measurement
Figure 27. Measuring Temperature Using a PNP Transistor
To prevent ground noise from interfering with the
measurement, the more negative terminal of the sensor is not
referenced to ground, but is biased above ground by an internal
diode at the D− input. C1 can optionally be added as a noise
filter (recommended maximum value of 1000 pF). However, a
better option in noisy environments is to add a filter, as
described in the Series Resistance Cancellation section.
The results of remote temperature measurements are stored in
10-bit, twos complement format, as listed in Table 15. The extra
resolution for the temperature measurements is held in the
Extended Resolution Register 2 (0x77). This gives temperature
readings with a resolution of 0.25°C.
Rev. 0 | Page 21 of 76
ADT7490
VDD
I
N2 × I
N1 × I
IBIAS
REMOTE
SENSING
TRANSISTOR D+
LPF
VOUT+
fC = 65kHz
VOUT–
TO ADC
06789-023
D–
Figure 28. Signal Conditioning for Remote Diode Temperature Sensors
100Ω
Parasitic resistance to the ADT7490 D+ and D− inputs (seen in
series with the remote diode) is caused by a variety of factors,
including PCB track resistance and track length. This series
resistance appears as a temperature offset in the remote sensor’s
temperature measurement. This error typically causes a 0.5°C offset
per ohm of parasitic resistance in series with the remote diode.
The ADT7490 automatically cancels out the effect of this series
resistance on the temperature reading, giving a more accurate
result without the need for user characterization of this resistance. The ADT7490 is designed to automatically cancel,
typically up to 1.5 kΩ of resistance. By using an advanced
temperature measurement method, this is transparent to the
user. This feature allows resistances to be added to the sensor
path to produce a filter, allowing the part to be used in noisy
environments.
REMOTE
TEMPERATURE
SENSOR
100Ω
D–
Figure 29. Filter Between Remote Sensor and ADT7490
FACTORS AFFECTING DIODE ACCURACY
Remote Sensing Diode
The ADT7490 is designed to work with either substrate transistors
built into processors or discrete transistors. Substrate transistors
are generally PNP types with the collector connected to the
substrate. Discrete types can be either PNP or NPN transistors
connected as a diode (base-shorted to the collector). To reduce
the error due to variations in both substrate and discrete
transistors, a number of factors should be taken into
consideration:
•
Noise Filtering
For temperature sensors operating in noisy environments,
previous practice was to place a capacitor across the D+ pin and
the D− pin to help combat the effects of noise. However, large
capacitances affect the accuracy of the temperature measurement,
leading to a recommended maximum capacitor value of 1000 pF.
This capacitor reduces the noise, but does not eliminate it, which
makes using the sensor difficult in a very noisy environment.
The ADT7490 has a major advantage over other devices for
eliminating the effects of noise on the external sensor. Using the
series resistance cancellation feature, a filter can be constructed
between the external temperature sensor and the part. The effect
of any filter resistance seen in series with the remote sensor is
automatically canceled from the temperature result.
D+
1nF
06789-024
SERIES RESISTANCE CANCELLATION
The ideality factor, nf, of the transistor is a measure of the
deviation of the thermal diode from ideal behavior. The
ADT7490 is trimmed for an nf value of 1.008. Use the
following equation to calculate the error introduced at a
temperature T (°C) when using a transistor whose nf does
not equal 1.008. Refer to the data sheet for the related CPU
to obtain the nf values.
ΔT = (nf − 1.008)/1.008 × (273.15 K + T)
To factor this in, the user can write the ΔT value to the
offset register. The ADT7490 automatically adds it to or
subtracts it from the temperature measurement.
•
The construction of a filter allows the ADT7490 and the remote
temperature sensor to operate in noisy environments. Figure 29
shows a low-pass RC filter with the following values:
R = 100 Ω, C = 1 nF
This filtering reduces both common-mode noise and
differential noise.
Rev. 0 | Page 22 of 76
Some CPU manufacturers specify the high and low current
levels of the substrate transistors. The high current level of
the ADT7490, IHIGH, is 192 μA and the low level current,
ILOW, is 12 μA. If the ADT7490 current levels do not match
the current levels specified by the CPU manufacturer, it
may be necessary to remove an offset. The CPU’s data
sheet advises whether this offset needs to be removed and
how to calculate it. This offset can be programmed to the
offset register. It is important to note that if more than one
offset must be considered, the algebraic sum of these
offsets must be programmed to the offset register.
ADT7490
Temperature Offset Registers
If a discrete transistor is used with the ADT7490, the best
accuracy is obtained by choosing devices according to the
following criteria:
•
•
•
•
Register 0x70, Remote 1 Temperature Offset = 0x00 (0°C default)
Register 0x71, Local Temperature Offset = 0x00 (0°C default)
Base-emitter voltage greater than 0.25 V at 12 μA at the
highest operating temperature.
Base-emitter voltage less than 0.95 V at 192 μA at the
lowest operating temperature.
Base resistance less than 100 Ω.
Small variation in hFE (such as 50 to 150) that indicates
tight control of VBE characteristics.
Register 0x72, Remote 2 Temperature Offset = 0x00 (0°C default)
Register 0x94, PECI0 Temperature Offset = 0x00 (0°C default)
Register 0x95, PECI1 Temperature Offset = 0x00 (0°C default)
Register 0x96, PECI2 Temperature Offset = 0x00 (0°C default)
Register 0x97, PECI3 Temperature Offset = 0x00 (0°C default)
Transistors, such as 2N3904, 2N3906, or equivalents in SOT-23
packages, are suitable devices to use.
Reading Temperature from the ADT7490
It is important to note that temperature can be read from the
ADT7490 as an 8-bit value (with 1°C resolution) or as a 10-bit
value (with 0.25°C resolution). If only 1°C resolution is required, the temperature readings can be read back at any time
and in no particular order.
If the 10-bit measurement is required, it involves a 2-register
read for each measurement. The Extended Resolution 2 register
(0x77) should be read first. This causes all temperature reading
registers to be frozen until all temperature reading registers
have been read from. This prevents an MSB reading from being
updated while its two LSBs are being read and vice versa.
Nulling Out Temperature Errors
As CPUs run faster, it becomes more difficult to avoid high
frequency clocks when routing the D+/D− traces around a
system board. Even when recommended layout guidelines are
followed, some temperature errors may still be attributable to
noise coupled onto the D+/D− lines. Constant high frequency
noise usually attenuates or increases temperature measurements
by a linear, constant value.
The ADT7490 has temperature offset registers at Address 0x70,
Address 0x71, and Address 0x72 for the Remote 1, local, and
Remote 2 temperature channels, respectively. By performing a
one-time calibration of the system, the user can determine the
offset caused by system board noise and null it out using the
offset registers. The offset registers automatically add a twos
complement 8-bit reading to every temperature measurement.
The temperature offset range and resolution is selected by
setting Bit 1 of Register 0x7C. This ensures that the readings
in the temperature measurement registers are as accurate as
possible. Setting this bit to 0 means the LSBs add 0.5°C offset
to the temperature reading, so the 8-bit register effectively
allows temperature offsets from −63°C to +64°C with a resolution of 0.5°C. Setting this bit to 1 means the LSBs add 1°C offset
to the temperature reading, so the 8-bit register effectively
allows temperature offsets of up to −63°C to +127°C with a
resolution of 1°C. For the PECI offset registers, the resolution is
always 1°C.
Temperature Measurement Limit Registers
Associated with each temperature measurement channel are
high and low limit registers. Exceeding the programmed high or
low limit causes the appropriate status bit to be set. Exceeding
either limit can also generate SMBALERT interrupts (depending on the way the interrupt mask register is programmed and
assuming that SMBALERT is set as an output on the
appropriate pin).
ADDITIONAL ADC FUNCTIONS FOR
TEMPERATURE MEASUREMENT
A number of other functions are available on the ADT7490 to
offer the system designer increased flexibility.
Turn-Off Averaging
For each temperature measurement read from a value register,
16 readings have actually been made internally, and the results
averaged, before being placed into the value register. Sometimes
it is necessary to take a very fast measurement. Setting Bit 4 of
Configuration Register 2 (0x73) turns averaging off. The default
round-robin cycle time with averaging off is a maximum of 23 ms.
Table 17. Conversion Time with Averaging Disabled
Channel
Voltage Channels
Remote Temperature 1
Remote Temperature 2
Local Temperature
Measurement Time (ms)
0.7
7
7
1.3
When Bit 7 of Configuration Register 6 (0x10) is set, the default
round-robin cycle time increases to a maximum of 193 ms.
Table 18. Conversion Time with Averaging Enabled
Channel
Voltage Channels
Remote Temperature
Local Temperature
Rev. 0 | Page 23 of 76
Measurement Time (ms)
11
39
12
ADT7490
Single-Channel ADC Conversions
Setting Bit 6 of Configuration Register 2 (Register 0x73) places
the ADT7490 into single-channel ADC conversion mode. In
this mode, the ADT7490 can be made to read a single
temperature channel only. The appropriate ADC channel is
selected by writing to Bits [7:4] of the TACH1 Minimum High
Byte register (0x55).
The fans run at this speed until the temperature drops below
THERM minus hysteresis. This can be disabled by setting the
BOOST bit in Configuration Register 3, Bit 2 (0x78). The
hysteresis value for the THERM temperature limit is the value
programmed into the hysteresis registers (0x6D and 0x6E). The
default hysteresis value is 4°C.
THERM LIMIT
Table 19. Programming Single-Channel ADC Mode for
Temperatures
Channel Selected
Remote 1 temperature
Local temperature
Remote 2 temperature
FANS
Configuration Register 2 (Register 0x73)
100%
Figure 30. THERM Temperature Limit Operation
Bit 4 (AVG) = 1, averaging off.
Bit 6 (CONV) = 1, single-channel convert mode.
THERM can be disabled by setting Bit 2 of Configuration
Register 4 (0x7D). THERM can also be disabled by:
Overtemperature Events
•
In Offset 64 mode, writing −64°C to the appropriate
THERM temperature limit.
•
In twos complement mode, writing −128°C to the
appropriate THERM temperature limit.
Overtemperature events on any of the temperature channels can
be detected and dealt with automatically in automatic fan speed
control mode. Register 0x6A to Register 0x6C are the THERM
temperature limits for the local and remote diode temperature
channels. The equivalent PECI limit is TCONTROL in Register 0x3D.
When a temperature exceeds its THERM temperature limit, all
PWM outputs run at 100% duty cycle (default). This can be
changed to maximum PWM duty cycle as programmed in
Register 0x38, Register 0x39, and Register 0x3A, by setting
Bit 3 of Register 0x7D.
Rev. 0 | Page 24 of 76
06789-029
Bits [7:4], Register 0x55
0101
0110
0111
HYSTERESIS (°C)
TEMPERATURE
ADT7490
LIMITS, STATUS REGISTERS, AND INTERRUPTS
LIMIT VALUES
16-Bit Limits
Associated with each measurement channel on the ADT7490
are high and low limits. These can form the basis of system
status monitoring; a status bit can be set for any out-of-limit
condition and is detected by polling the device. Alternatively,
SMBALERT interrupts can be generated to flag out-of-limit
conditions to a processor or microcontroller.
The fan TACH measurements are 16-bit results. The fan TACH
limits are also 16 bits, consisting of a high byte and low byte.
Only high limits exist for fan TACHs because fans running
under speed or stalled are normally the only conditions of
interest. Because the fan TACH period is actually being
measured, exceeding the limit indicates a slow or stalled fan.
8-Bit Limits
Fan Limit Registers
The following is a list of 8-bit limits on the ADT7490.
Register 0x54, TACH1 Minimum Low Byte = 0xFF default
Voltage Limit Registers
Register 0x55, TACH1 Minimum High Byte = 0xFF default
Register 0x44, +2.5VIN Low Limit = 0x00 default
Register 0x56, TACH2 Minimum Low Byte = 0xFF default
Register 0x45, +2.5VIN High Limit = 0xFF default
Register 0x57, TACH2 Minimum High Byte = 0xFF default
Register 0x46, VCCP Low Limit = 0x00 default
Register 0x58, TACH3 Minimum Low Byte = 0xFF default
Register 0x47, VCCP High Limit = 0xFF default
Register 0x59, TACH3 Minimum High Byte = 0xFF default
Register 0x48, VCC Low Limit = 0x00 default
Register 0x5A, TACH4 Minimum Low Byte = 0xFF default
Register 0x49, VCC High Limit = 0xFF default
Register 0x5B, TACH4 Minimum High Byte = 0xFF default
Register 0x4A, +5VIN Low Limit = 0x00 default
Out-of-Limit Comparisons
Once all limits have been programmed, the ADT7490 can be
enabled for monitoring. The ADT7490 measures all voltage and
temperature measurements in round-robin format and sets the
appropriate status bit to indicate out-of-limit conditions. TACH
measurements are not part of this round-robin cycle. Comparisons are done differently depending on whether the measured
value is being compared to a high or low limit.
Register 0x4B, +5VIN High Limit = 0xFF default
Register 0x4C, +12VIN Low Limit = 0x00 default
Register 0x4D, +12VIN High Limit = 0xFF default
Register 0x84, VTT Low Limit = 0x00 default
Register 0x86, VTT High Limit = 0xFF default
Register 0x85, IMON Low Limit = 0x00 default
High Limit > Comparison Performed
Register 0x87, IMON High = 0xFF default
Low Limit ≤ Comparison Performed
Temperature Limit Registers
Register 0x4E, Remote 1 Temperature Low Limit = 0x81 default
Register 0x4F, Remote 1 Temperature High Limit = 0x7F default
Analog Monitoring Cycle Time
Register 0x6A, Remote 1 THERM Limit = 0x64 default
Register 0x50, Local Temperature Low Limit = 0x81 default
Register 0x51, Local Temperature High Limit = 0x7F default
Register 0x6B, Local THERM Limit = 0x64 default
Register 0x52, Remote 2 Temperature Low Limit = 0x81 default
Register 0x53, Remote 2 Temperature High Limit = 0x7F default
Register 0x6C, Remote 2 THERM Limit = 0x64 default
Register 0x34, PECI Low Limit = 0x81 default
Register 0x35, PECI High Limit = 0x00 default
Register 0x3D, PECI TCONTROL Limit = 0x00 default
Voltage and temperature channels use a window comparator
for error detecting and, therefore, have high and low limits.
Fan speed measurements use only a low limit.
The analog monitoring cycle begins when a 1 is written to the
start bit (Bit 0) of Configuration Register 1 (0x40). The ADC
measures each analog input in turn, and, as each measurement
is completed, the result is automatically stored in the
appropriate value register. This round-robin monitoring cycle
continues unless disabled by writing a 0 to Bit 0 of Configuration
Register 1.
As the ADC is normally left to free-run in this manner, the
time taken to monitor all the analog inputs is normally not
of interest, because the most recently measured value of any
input can be read out at any time. For applications where the
monitoring cycle time is important, it can easily be calculated.
THERM Timer Limit Register
Register 0x7A, THERM Timer Limit = 0x00 default
Rev. 0 | Page 25 of 76
ADT7490
The total number of channels measured consists of
•
•
•
•
(OOL) of Interrupt Status Register 1 (0x41), a Logic 1 indicates
an out-of-limit event has been flagged in Interrupt Status
Register 2. This means the user also needs to read Interrupt
Status Register 2. There is a similar OOL bit in Interrupt Status
Register 2 and Interrupt Status Register 3,indicating an out-oflimit event in the next status register.
Six dedicated supply voltage inputs
Supply voltage (VCC pin)
Local temperature
Two remote temperatures
As mentioned previously, the ADC performs round-robin
conversions and takes 11 ms for each voltage measurement,
12 ms for a local temperature reading, and 39 ms for each
remote temperature reading. The total monitoring cycle time
for averaged voltage and temperature monitoring is, therefore,
nominally
(7 × 11) + 12 + (2 × 39) = 167 ms
Fan TACH measurements and PECI thermal measurements are
made in parallel and are not synchronized with the analog
measurements in any way.
INTERRUPT STATUS REGISTERS
The results of limit comparisons are stored in Interrupt Status
Register 1 to Interrupt Status Register 4. The status register bit
for each channel reflects the status of the last measurement and
limit comparison on that channel. If a measurement is within
limits, the corresponding interrupt status register bit is cleared
to 0. If the measurement is out of limit, the corresponding
interrupt status register bit is set to 1.
The state of the various measurement channels can be polled by
reading the interrupt status registers over the serial bus. In Bit 7
Alternatively, Pin 10 or Pin 14 can be configured as an SMBALERT
output. This hard interrupt automatically notifies the system
supervisor of an out-of-limit condition. Reading the interrupt
status registers clears the appropriate status bit as long as the
error condition that caused the interrupt has cleared. Interrupt
Status register bits are sticky. Whenever an interrupt status bit is
set, indicating an out-of-limit condition, it remains set even if
the event that caused it has gone away (until read).
The only way to clear the interrupt status bit is to read the
interrupt status register after the event has gone away. Interrupt
status mask registers allow individual interrupt sources to be
masked from causing an SMBALERT on the dedicated alert pin.
However, if one of these masked interrupt sources goes out of
limit, its associated interrupt status bit is set in the interrupt
status registers.
Full details of the Interrupt Status and Interrupt Mask registers
associated with each measurement channels are detailed in the
Table 20 and in the full register map in the Register Tables
section.
Table 20. Interrupt Status and Interrupt Mask Register Address and Bit Assignments
Interrupt Status
Register
0x41
0x42
0x43
0x81
Interrupt Mask
Register
0x74
0x75
0x82
0x83
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
OOL
D2 FAULT
OOL
VTT
R2T
D1 FAULT
RES
IMON
LT
FAN4/THERM
RES
PECI3
R1T
FAN3
RES
PECI2
+5VIN
FAN2
OVT
PECI1
VCC
FAN1
COMM
RES
VCCP
OOL
DATA
RES
+2.5VIN/THERM
+12VIN
PECI0
RES
Rev. 0 | Page 26 of 76
ADT7490
SMBALERT Interrupt Behavior
HIGH LIMIT
The ADT7490 can be polled for status, or an SMBALERT
interrupt can be generated for out-of-limit conditions. It is
important to note how the SMBALERT output and status
bits behave when writing interrupt handler software.
TEMPERATURE
CLEARED ON READ
(TEMP BELOW LIMIT)
HIGH LIMIT
STICKY
STATUS BIT
SMBALERT
STICKY
STATUS BIT
06789-030
TEMP BACK IN LIMIT
(STATUS BIT STAYS SET)
SMBALERT
Figure 31. SMBALERT and Status Bit Behavior
Figure 31 shows how the SMBALERT output and sticky status
bits behave. Once a limit is exceeded, the corresponding status
bit is set to 1. The status bit remains set until the error condition subsides and the status register is read. The status bits
are referred to as sticky, because they remain set until read
by software. This ensures that an out-of-limit event cannot
be missed if software is polling the device periodically.
Note that the SMBALERT output remains low for the entire
duration that a reading is out of limit and until the status
register has been read. This has implications on how software handles the interrupt.
Figure 32. How Masking the Interrupt Source Affects SMBALERT Output
Enabling the SMBALERT Interrupt Output
The SMBALERT interrupt function is disabled by default.
Pin 10 or Pin 14 can be reconfigured as an SMBALERT
output to signal out-of-limit conditions.
Table 21. Configuring Pin 10 as SMBALERT Output
Register
Configuration Register 3
(Register 0x78) Bit 0
Bit Setting
[1] Pin 10 = SMBALERT
[0] Pin 10 = PWM2 (default)
Pin 14 on the ADT7490 has three possible functions:
SMBALERT, THERM, and TACH4. The user chooses
the required functionality by setting Bit 0 and Bit 1 of
Configuration Register 4 at Address 0x7D.
To prevent the system from being tied up servicing interrupts,
it is recommend to handle the SMBALERT interrupt as follows:
5.
6.
7.
INTERRUPT MASK BIT
CLEARED
(SMBALERT REARMED)
Assigning THERM Functionality to a Pin
Handling SMBALERT Interrupts
1.
2.
3.
4.
INTERRUPT
MASK BIT SET
CLEARED ON READ
(TEMP BELOW LIMIT)
06789-031
TEMP BACK IN LIMIT
(STATUS BIT STAYS SET)
TEMPERATURE
Detect the SMBALERT assertion.
Enter the interrupt handler.
Read the status registers to identify the interrupt source.
Mask the interrupt source by setting the appropriate mask
bit in the interrupt mask registers (0x74, 0x75, 0x82, and
0x83).
Take the appropriate action for a given interrupt source.
Exit the interrupt handler.
Periodically poll the status registers. If the interrupt status
bit has cleared, reset the corresponding interrupt mask bit
to 0. This causes the SMBALERT output and status bits to
behave as shown in Figure 32.
Masking Interrupt Sources
The interrupt mask registers allow individual interrupt sources
to be masked out to prevent SMBALERT interrupts. Note that
masking an interrupt source prevents only the SMBALERT
output from being asserted; the appropriate status bit is set
normally see Figure 32. Full details of the status and mask
registers associated with each measurement channel are
detailed in Table 20 and Table 24.
If THERM is enabled (Bit 1, Configuration Register 3
at Address 0x78):
•
•
Pin 22 becomes THERM.
If Pin 14 is configured as THERM (Bit 0 and Bit 1 of
Configuration Register 4 at Address 0x7D), THERM is
enabled on this pin.
If THERM is not enabled:
•
•
Pin 22 becomes a 2.5 VIN measurement input.
If Pin 14 is configured as THERM, THERM is disabled on
this pin.
Table 22. Configuring Pin 14 in Register 0x7D
Bit 0
0
0
1
1
Rev. 0 | Page 27 of 76
Bit 1
0
1
0
1
Function
TACH4
THERM
SMBALERT
Reserved
ADT7490
THERM as an Input
Bit 1 of the THERM timer is set and Bit 0 now becomes the LSB
of the timer with a resolution of 22.76 ms (see Figure 34).
When THERM is configured as an input, the user can time
assertions on the THERM pin. This can be useful for connecting to the PROCHOT output of a CPU to gauge system
performance.
THERM
THERM
TIMER
(REG. 0x79)
The user can also set up the ADT7490 so that the fans run at
100% when the THERM pin is driven low externally,. The fans
run at 100% for the duration of the time that the THERM pin is
pulled low. This is done by setting the BOOST bit (Bit 2) in
Configuration Register 3 (Address 0x78) to 1. This works only if
the fan is already running, for example, in manual mode when
the current duty cycle is above 0x00, or in automatic mode
when the temperature is above TMIN.
0 0 0 0 0 0 0 1
7 6 5 4 3 2 1 0
THERM ASSERTED
≤ 22.76ms
THERM
ACCUMULATE THERM LOW
ASSERTION TIMES
THERM
TIMER
(REG. 0x79)
If the temperature is below TMIN or if the duty cycle in manual
mode is set to 0x00, pulling the THERM low externally has no
effect. See Figure 33 for more information.
0 0 0 0 0 0 1 0
7 6 5 4 3 2 1 0
THERM ASSERTED
≥ 45.52ms
THERM
ACCUMULATE THERM LOW
ASSERTION TIMES
THERM
TIMER
(REG. 0x79)
0 0 0 0 0 1 0 1
7 6 5 4 3 2 1 0 THERM ASSERTED ≥ 113.8ms
(91.04ms + 22.76ms)
06789-033
TMIN
Figure 34. Understanding the THERM Timer
THERM
When using the THERM timer, be aware of the following.
After a THERM timer read (Register 0x79):
•
•
THERM ASSERTED TO LOW AS AN INPUT:
FANS DO NOT GO TO 100%, BECAUSE
TEMPERATURE IS ABOVE TMIN AND FANS
ARE ALREADY RUNNING.
06789-032
THERM ASSERTED TO LOW AS AN INPUT:
FANS DO NOT GO TO 100%, BECAUSE
TEMPERATURE IS BELOW TMIN.
Figure 33. Asserting THERM Low as an Input
in Automatic Fan Speed Control Mode
If the THERM timer is read during a THERM assertion, the
following happens:
•
•
THERM TIMER
The ADT7490 has an internal timer to measure THERM
assertion time. For example, the THERM input can be connected to the PROCHOT output of a CPU to measure system
performance. The THERM input can also be connected to the
output of a trip point temperature sensor.
The timer is started on the assertion of the ADT7490’s THERM
input and stopped when THERM is deasserted. The timer
counts THERM times cumulatively, that is, the timer resumes
counting on the next THERM assertion. The THERM timer
continues to accumulate THERM assertion times until the
timer is read (it is cleared on read), or until it reaches full scale.
If the counter reaches full scale, it stops at that reading until
cleared.
The 8-bit THERM timer status register (0x79) is designed so
that Bit 0 is set to 1 on the first THERM assertion. Once the
cumulative THERM assertion time has exceeded 45.52 ms,
The contents of the timer are cleared on read.
Bit 5 of Interrupt Status 2 register (0x42) needs to be
cleared (assuming that the THERM timer limit has
been exceeded).
•
•
The contents of the timer are cleared.
Bit 0 of the THERM timer is set to 1, because a THERM
assertion is occurring.
The THERM timer increments from zero.
If the THERM timer limit (Register 0x7A) = 0x00, the F4P
bit is set.
Generating SMBALERT Interrupts from THERM
Timer Events
The ADT7490 can generate SMBALERTs when a programmable THERM timer limit has been exceeded. This allows the
system designer to ignore brief, infrequent THERM assertions
while capturing longer THERM timer events. Register 0x7A is
the THERM timer limit register. This 8-bit register allows a
limit from 0 sec (first THERM assertion) to 5.825 sec to be set
before an SMBALERT is generated. The THERM timer value is
compared with the contents of the THERM timer limit register.
If the THERM timer value exceeds the THERM timer limit
Rev. 0 | Page 28 of 76
ADT7490
This allows fail-safe system cooling. If this bit = 0, the
fans run at their current settings and are not affected by
THERM events. If the fans are not already running when
THERM is asserted, the fans do not run to full speed.
Select whether THERM timer events should generate
SMBALERT interrupts.
Bit 5 of Interrupt Mask Register 2 (0x75) or Bit 0 of
Interrupt Mask Register 1 (0x74), depending on which
pins are configured as a THERM timer, when set, masks
out SMBALERTs when the THERM timer limit value
is exceeded. This bit should be cleared if SMBALERTs
based on THERM events are required.
Select a suitable THERM limit value.
This value determines whether an SMBALERT is generated on the first THERM assertion, or only if a cumulative
THERM assertion time limit is exceeded. A value of 0x00
causes an SMBALERT to be generated on the first THERM
assertion.
Select a THERM monitoring time.
This value specifies how often OS- or BIOS-level software
checks the THERM timer. For example, BIOS can read the
THERM timer once an hour to determine the cumulative
THERM assertion time. If, for example, the total THERM
assertion time is <22.76 ms in Hour 1, >182.08 ms in Hour 2,
and >5.825 sec in Hour 3, this indicates that system performance is degrading significantly because THERM is
asserting more frequently on an hourly basis.
value, the FAN4 bit (Bit 5) of Status Register 2 is set and an
SMBALERT is generated.
Note that depending on which pins are configured as a THERM
timer, setting the F4P bit (Bit 5) of the Interrupt Mask Register 2
(0x75), or bit 0 of the Interrupt Mask Register 1 (0x74), masks
out SMBALERT; although the FAN4 bit of Interrupt Status
Register 2 is still set if the THERM timer limit is exceeded.
3.
Figure 35 is a functional block diagram of the THERM timer,
THERM limit, and its associated circuitry. Writing a value of
0x00 to the THERM Timer Limit register (Register 0x7A)
causes an SMBALERT to be generated on the first THERM
assertion. A THERM timer limit value of 0x01 generates an
SMBALERT once cumulative THERM assertions exceed 45.52 ms.
4.
Configuring the Relevant THERM Behavior
2.
Configure the desired pin as the THERM timer input.
Setting Bit 1 (THERM timer enable) of Configuration
Register 3 (Register 0x78) enables the THERM timer
monitoring functionality. This is disabled on Pin 14 and
Pin 22 by default.
Setting Bit 0 and Bit 1 (Pin 14 Func) of Configuration
Register 4 (Register 0x7D) enables THERM timer output
functionality on Pin 22 (Bit 1 of Configuration Register 3,
THERM, must also be set). Pin 14 can also be used as
TACH4.
Select the desired fan behavior for THERM timer events.
Assuming the fans are running, setting Bit 2 (BOOST bit)
of Configuration Register 3 (Register 0x78) causes all fans
to run at 100% duty cycle whenever THERM is asserted.
5.
2.914s
1.457s
728.32ms
364.16ms THERM TIMER STATUS
182.08ms (REGISTER 0x79)
91.04ms
45.52ms
22.76ms
2.914s
1.457s
728.32ms
THERM TIMER LIMIT 364.16ms
(REGISTER 0x7A) 182.08ms
91.04ms
45.52ms
22.76ms
0 1 2 3 4 5 6 7
7 6 5 4 3 2 1 0
THERM
THERM TIMER CLEARED ON READ
COMPARATOR
IN
OUT
LATCH
FAN4 BIT (BIT 5)
INTERRUPT STATUS 2
REGISTER
SMBALERT
RESET
CLEARED
ON READ
1 = MASK
FAN4 BIT (BIT 5)
INTERRUPT MASK REGISTER 2
(REGISTER 0x75)
Figure 35. Functional Block Diagram of THERM Monitoring Circuitry
Rev. 0 | Page 29 of 76
06789-034
1.
ADT7490
Alternatively, OS- or BIOS-level software can timestamp when
the system is powered on. If an SMBALERT is generated due to
the THERM timer limit being exceeded, another timestamp can
be taken. The difference in time can be calculated for a fixed
THERM timer limit time. For example, if it takes one week for a
THERM timer limit of 2.914 sec to be exceeded, and the next
time it takes only 1 hour, this is an indication of a serious degradation in system performance.
Enabling and Disabling THERM on Individual Channels
Configuring the THERM Pin as an Output
If THERM hysteresis is enabled and THERM is disabled (Bit 2
of Configuration Register 4, 0x7D), the THERM event is not
reflected in the status register and the fans do not go to full
speed. If THERM hysteresis is disabled and THERM is disabled
(Bit 2 of Configuration Register 4, 0x7D) and assuming the
appropriate pin is configured as THERM, the THERM pin
asserts low when a THERM event occurs.
In addition to monitoring THERM as an input, the ADT7490 can
optionally drive THERM low as an output. When PROCHOT is
bidirectional, THERM can be used to throttle the processor by
asserting PROCHOT. The user can preprogram system-critical
thermal limits. If the temperature exceeds a thermal limit by
0.25°C, THERM asserts low. If the temperature is still above the
thermal limit on the next monitoring cycle, THERM stays low.
THERM remains asserted low until the temperature is equal to
or below the thermal limit. Because the temperature for that
channel is measured only once for every monitoring cycle, after
THERM asserts, it is guaranteed to remain low for at least one
monitoring cycle.
The THERM pin can be configured to assert low if the Remote 1
THERM, local THERM, Remote 2 THERM or PECI temperature limits are exceeded by 0.25°C. The THERM temperature
limit registers are at Register 0x6A, Register 0x6B, and Register
0x6C, respectively. Setting Bits [5:7] of Configuration Register 5
(0x7C) enables the THERM output feature for the Remote 1,
local, and Remote 2 temperature channels, respectively. Figure 36
shows how the THERM pin asserts low as an output in the event
of a critical overtemperature.
THERM LIMIT
0.25°C
THERM LIMIT
TEMP
The THERM pin can be enabled/disabled for individual or
combinations of temperature channels using Bits [7:5] of
Configuration Register 5 (0x7C).
THERM Hysteresis
Setting Bit 0 of Configuration Register 7 (0x11) disables
THERM hysteresis.
If THERM and THERM hysteresis are both enabled, the
THERM output asserts as expected.
THERM Operation in Manual Mode
In manual mode, THERM events do not cause fans to go to full
speed, unless Bit 5 of Configuration Register 1 (0x40) is set to 1.
Additionally, Bit 3 of Configuration Register 4 (0x7D) can be
used to select PWM speed on THERM event (100% or
maximum PWM).
Bit 2 in Configuration Register 4 (0x7D) can be set to disable
THERM events from affecting the fans.
FAN DRIVE USING PWM CONTROL
The ADT7490 uses pulse-width modulation (PWM) to control
fan speed. This relies on varying the duty cycle (or on/off ratio)
of a square wave applied to the fan to vary the fan speed. The
external circuitry required to drive a fan using PWM control is
extremely simple. For 4-wire fans, the PWM drive might need
only a pull-up resistor. In many cases, the 4-wire fan PWM
input has a built-in, pull-up resistor.
The ADT7490 PWM frequency can be set to a selection of
low frequencies or a single high PWM frequency. The low
frequency options are used for 3-wire fans, while the high
frequency option is usually used with 4-wire fans.
MONITORING
CYCLE
06789-035
THERM
Figure 36. Asserting THERM as an Output, Based on Tripping THERM Limits
An alternative method of disabling THERM is to program the
THERM temperature limit to –63°C or less in Offset 64 mode,
or −128°C or less in twos complement mode; that is, for
THERM temperature limit values less than –63°C or –128°C,
respectively, THERM is disabled.
For 3-wire fans, a single N-channel MOSFET is the only drive
device required. The specifications of the MOSFET depend on
the maximum current required by the fan being driven and
the input capacitance of the FET. Because a 10 kΩ (or greater)
resistor must be used as a PWM pull-up, an FET with large
input capacitance can cause the PWM output to become
distorted and adversely affect the fan control range. This is a
requirement only when using high frequency PWM mode.
Typical notebook fans draw a nominal 170 mA, therefore, SOT
devices can be used where board space is a concern. In
desktops, fans typically draw 250 mA to 300 mA each. If several
fans are driven in parallel from a single PWM output or drive
Rev. 0 | Page 30 of 76
ADT7490
larger server fans, the MOSFET must handle the higher current
requirements. The only other stipulation is that the MOSFET
should have a gate voltage drive, VGS < 3.3 V, for direct
interfacing to the PWM output pin. The MOSFET should also
have a low on resistance to ensure that there is not a significant
voltage drop across the FET, which would reduce the voltage
applied across the fan and, therefore, the maximum operating
speed of the fan.
circuit to perform better than 3-wire fans, especially for high
frequency applications.
Figure 39 shows a typical drive circuit for 4-wire fans.
12V 12V
12V, 4-WIRE FAN
10kΩ
TACH
4.7kΩ
ADT7490
Figure 37 shows how to drive a 3-wire fan using PWM control.
12V
10kΩ
ADT7490
Driving Two Fans from PWM3
The ADT7490 has four TACH inputs available for fan speed
measurement, but only three PWM drive outputs. If a fourth
fan is being used in the system, it should be driven from the
PWM3 output in parallel with the third fan.
10kΩ
06789-036
Q1
NDT3055L
Figure 37. Driving a 3-Wire Fan Using an N-Channel MOSFET
Figure 37 uses a 10 kΩ pull-up resistor for the TACH signal.
This assumes that the TACH signal is an open-collector from
the fan. In all cases, the TACH signal from the fan must be kept
below 3.6 V maximum to prevent damaging the ADT7490.
Figure 38 shows a fan drive circuit using an NPN transistor
such as a general-purpose MMBT2222. While these devices
are inexpensive, they tend to have much lower current handling capabilities and higher on resistance than MOSFETs.
When choosing a transistor, care should be taken to ensure
that it meets the fan’s current requirements. Ensure that the
base resistor is chosen so the transistor is saturated when the
fan is powered on.
12V
12V
10kΩ
TACH
10kΩ
4.7kΩ
ADT7490
TACH
12V
FAN
1N4148
3.3V
470Ω
Q1
MMBT2222
Figure 40 shows how to drive two fans in parallel using low
cost NPN transistors. Figure 41 shows the equivalent circuit
using a MOSFET.
Because the MOSFET can handle up to 3.5 A, it is simply a
matter of connecting another fan directly in parallel with the
first. Care should be taken in designing drive circuits with
transistors and FETs to ensure the PWM outputs are not
required to source current, and that they sink less than the
5 mA maximum current specified in the data sheet.
Driving up to Three Fans from PWM3
TACH measurements for fans are synchronized to particular
PWM channels; for example, TACH1 is synchronized to
PWM1. TACH3 and TACH4 are both synchronized to PWM3,
so PWM3 can drive two fans. Alternatively, PWM3 can be programmed to synchronize TACH2, TACH3, and TACH4 to the
PWM3 output. This allows PWM3 to drive two or three fans.
In this case, the drive circuitry looks the same, as shown in
Figure 40 and Figure 41. The SYNC bit in Register 0x62 enables
this function.
Synchronization is not required in high frequency mode when
used with 4-wire fans.
06789-037
PWM
PWM
3.3V
Figure 39. Driving a 4-Wire Fan
1N4148
3.3V
PWM
TACH
2kΩ
12V
FAN
TACH
4.7kΩ
VCC
PWM
10kΩ
TACH
TACH
06789-038
12V
10kΩ
SYNC, Enhanced Acoustics Register 1 (Register 0x62)
Figure 38. Driving a 3-Wire Fan Using an NPN Transistor
Because the fan drive circuitry in 4-wire fans is not switched on
or off, as with previous PWM driven/powered fans, the internal
drive circuit is always on and uses the PWM input as a signal
instead of a power supply. This enables the internal fan drive
Bit 4 (SYNC) = 1, synchronizes TACH2, TACH3, and TACH4
to PWM3.
Rev. 0 | Page 31 of 76
ADT7490
12V
3.3V
3.3V
1N4148
ADT7490
TACH3
1kΩ
PWM3
3.3V
Q1
MMBT3904
2.2kΩ
10kΩ
TACH4
3.3V
Q2
MMBT2222
06789-039
10kΩ
Q3
MMBT2222
Figure 40. Interfacing Two Fans in Parallel to the PWM3 Output Using Low Cost NPN Transistors
3.3V
10kΩ
TYPICAL
TACH4
3.3V
ADT7490
+V
3.3V
+V
10kΩ
TYPICAL
5V OR
12V FAN
TACH
TACH3
3.3V
3.3V
1N4148
TACH
5V OR
12V FAN
10kΩ
TYPICAL
06789-040
Q1
NDT3055L
PWM3
Figure 41. Interfacing Two Fans in Parallel to the PWM3 Output Using a Single N-Channel MOSFET
VCC
LAYING OUT 3-WIRE FANS
12V
PULL-UP
4.7kΩ
TYP
12V OR 5V
1N4148
TACH
FAN SPEED
COUNTER
ADT7490
3.3V OR 5V
R2
Figure 43. Fan with TACH Pull-Up to VCC
R4
If the fan output has a resistive pull-up to 12 V, or other voltage
greater than 3.6 V, the fan output can be clamped with a Zener
diode, as shown in Figure 44. The Zener diode voltage should
be chosen so that it is greater than VIH of the TACH input but
less than 3.6 V, allowing for the voltage tolerance of the Zener. A
value of between 3 V and 3.6 V is suitable.
R3
Q1
MMBT2222
06789-041
PWM
TACH
Figure 42. Planning for 3-Wire Fans on a PCB
TACH Inputs
Signal conditioning in the ADT7490 accommodates the slow
rise and fall times typical of fan tachometer outputs. The maximum input signal range is 0 V to 3.6 V, even though VCC is
3.3 V. In the event that these inputs are supplied from fan
outputs that exceed 0 V to 3.6 V, either resistive attenuation
of the fan signal or diode clamping must be included to keep
inputs within an acceptable range.
Figure 43 to Figure 46 show circuits for the most common fan
TACH outputs.
If the fan TACH output has a resistive pull-up to VCC, it can be
connected directly to the fan input, as shown in Figure 43.
VCC
12V
Pins 9, 11, 12, and 14 (when configured as TACH inputs) are
high impedance inputs intended for fan speed measurement.
PULL-UP
4.7kΩ
TYPICAL
TACH
OUTPUT
TACH
ZD1*
FAN SPEED
COUNTER
ADT7490
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC
Figure 44. Fan with TACH Pull-Up to Voltage > 3.6 V, for Example, 12 V
Clamped with Zener Diode
If the fan has a strong pull-up (less than 1 kΩ) to 12 V or a
totem-pole output, a series resistor can be added to limit the
Zener current, as shown in Figure 45.
Rev. 0 | Page 32 of 76
06789-043
R1
TACH
OUTPUT
06789-042
Figure 42 shows how to lay out a common circuit arrangement
for 3-wire fans.
ADT7490
VCC
5V OR 12V
Fan Speed Measurement Registers
FAN
R1
10kΩ
TACH
OUTPUT
The fan tachometer registers are 16-bit values consisting of
a 2-byte read from the ADT7490.
TACH
ZD1
ZENER*
Register 0x28, TACH1 Low Byte = 0x00 default
FAN SPEED
COUNTER
Register 0x29, TACH1 High Byte = 0x00 default
ADT7490
06789-044
PULL-UP TYP
<1kΩ OR
TOTEM POLE
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC
Register 0x2B, TACH2 High Byte = 0x00 default
Figure 45. Fan with Strong TACH Pull-Up to >VCC or Totem-Pole Output,
Clamped with Zener Diode and Resistor
Register 0x2C, TACH3 Low Byte = 0x00 default
Alternatively, a resistive attenuator can be used, as shown
in Figure 46. R1 and R2 should be chosen such that
Register 0x2D, TACH3 High Byte = 0x00 default
Register 0x2E, TACH4 Low Byte = 0x00 default
2 V < VPULL-UP × R2/(RPULL-UP + R1 + R2) < 3.6 V
The fan inputs have an input resistance of nominally 160 kΩ to
ground, which should be taken into account when calculating
resistor values.
With a pull-up voltage of 12 V and pull-up resistor less than
1 kΩ, suitable values for R1 and R2 are 100 kΩ and 40 kΩ,
respectively. This gives a high input voltage of 3.42 V.
VCC
12V
R1
100kΩ
TACH
OUTPUT
TACH
R2
40kΩ
FAN SPEED
COUNTER
ADT7490
06789-045
<1kΩ
Register 0x2A, TACH2 Low Byte = 0x00 default
Figure 46. Fan with Strong TACH Pull-Up to >VCC or Totem-Pole Output,
Attenuated with R1/R2
The fan counter does not count the fan TACH output pulses
directly because the fan speed could be less than 1000 RPM,
and it takes several seconds to accumulate a reasonably large
and accurate count. Instead, the period of the fan revolution is
measured by gating an on-chip 90 kHz oscillator into the input
of a 16-bit counter for N periods of the fan TACH output (see
Figure 47), so the accumulated count is actually proportional
to the fan tachometer period and inversely proportional to the
fan speed.
N, the number of pulses counted, is determined by the settings
of the TACH pulses per revolution register (0x7B). This register
contains two bits for each fan, allowing one, two (default), three,
or four TACH pulses to be counted.
Register 0x2F, TACH4 High Byte = 0x00 default
Reading Fan Speed from the ADT7490
The measurement of fan speeds involves a 2-register read
for each measurement. The low byte should be read first.
This causes the high byte to be frozen until both high and
low byte registers have been read, preventing erroneous
TACH readings. The fan tachometer reading registers report
back the number of 11.11 μs period clocks (90 kHz oscillator)
gated to the fan speed counter, from the rising edge of the first
fan TACH pulse to the rising edge of the third fan TACH pulse
(assuming two pulses per revolution are being counted).
Because the device is essentially measuring the fan TACH
period, the higher the count value, the slower the fan is actually running. A 16-bit fan tachometer reading of 0xFFFF
indicates that either the fan has stalled or is running very
slowly (<100 RPM).
High Limit > Comparison Performed
Because the actual fan TACH period is being measured, falling
below a fan TACH limit by 1 sets the appropriate status bit and
can be used to generate an SMBALERT.
Fan TACH Limit Registers
The fan TACH limit registers are 16-bit values consisting of
two bytes.
Register 0x54, TACH1 Minimum Low Byte = 0xFF default
Register 0x55, TACH1 Minimum High Byte = 0xFF default
Register 0x56, TACH2 Minimum Low Byte = 0xFF default
Register 0x57, TACH2 Minimum High Byte = 0xFF default
Register 0x58, TACH3 Minimum Low Byte = 0xFF default
CLOCK
Register 0x59, TACH3 Minimum High Byte = 0xFF default
Register 0x5A, TACH4 Minimum Low Byte = 0xFF default
PWM
Register 0x5B, TACH4 Minimum High Byte = 0xFF default
1
2
06789-046
TACH
3
4
Figure 47. Fan Speed Measurement
Rev. 0 | Page 33 of 76
ADT7490
Fan Speed Measurement Rate
Fan Spin-Up
The fan TACH readings are normally updated once
every second.
The ADT7490 has a unique fan spin-up function. It spins
the fan at 100% PWM duty cycle until two TACH pulses are
detected on the TACH input. When two TACH pulses have
been detected, the PWM duty cycle goes to the expected
running value, for example, 33%. The advantage of this is that
fans have different spin-up characteristics and take different
times to overcome inertia. The ADT7490 runs the fans just fast
enough to overcome inertia and is quieter on spin-up than fans
programmed to spin up for a given spin-up time.
When set, the FAST bit (Bit 3) of Configuration Register 3 (0x78),
updates the fan TACH readings every 250 ms.
DC Bits
If any of the fans are not being driven by a PWM channel but
are powered directly from 5 V or 12 V, their associated dc bit
in Configuration Register 3 should be set. This allows TACH
readings to be taken on a continuous basis for fans connected
directly to a dc source. For 4-wire fans, once high frequency
mode is enabled, the dc bits do not need to be set because this is
automatically done internally.
Calculating Fan Speed
Assuming a fan with a two pulses per revolution, and with the
ADT7490 programmed to measure two pulses per revolution,
fan speed is calculated by
Fan Speed (RPM) = (90,000 × 60)/Fan TACH Reading
where Fan TACH Reading is the 16-bit fan tachometer reading.
Example
Fan Start-Up Timeout
To prevent the generation of false interrupts as a fan spins up,
because the fan is below running speed, the ADT7490 includes
a fan start-up timeout function. During this time, the ADT7490
looks for two TACH pulses. If two TACH pulses are not detected,
an interrupt is generated.
Fan start-up timeout can be disabled by setting Bit 3 (FSPDIS)
of Configuration Register 7 (0x11).
PWM1, PWM2, PWM3 Configuration
(Register 0x5C, Register 0x5D, Register 0x5E)
Bits [2:0] SPIN, start-up timeout for PWM1 = 0x5C, PWM2 =
0x5D, and PWM3 = 0x5E.
TACH1 High Byte (Register 0x29) = 0x17
000 = No start-up timeout
001 = 100 ms
010 = 250 ms default
011 = 400 ms
100 = 667 ms
101 = 1 sec
110 = 2 sec
111 = 4 sec
TACH1 Low Byte (Register 0x28) = 0xFF
What is Fan 1 speed in RPM?
Fan 1 TACH Reading = 0x17FF = 6143 (decimal)
RPM = (f × 60)/Fan 1 TACH Reading
RPM = (90000 × 60)/6143
Fan Speed = 879 RPM
Fan Pulses per Revolution
Disabling Fan Start-Up Timeout
Different fan models can output either one, two, three, or four
TACH pulses per revolution. Once the number of fan TACH
pulses has been determined, it can be programmed into the
TACH pulses per revolution register (0x7B) for each fan.
Alternatively, this register can be used to determine the number
or pulses per revolution output by a given fan. By plotting fan
speed measurements at 100% speed with different pulses per
revolution setting, the smoothest graph with the lowest
ripple determines the correct pulses per revolution value.
Although fan startup makes fan spin-ups much quieter than
fixed-time spin-ups, the option exists to use fixed spin-up
times. Setting Bit 3 (FSPDIS) to 1 in Configuration Register 7
(Register 0x11) disables the spin-up for two TACH pulses.
Instead, the fan spins up for the fixed time as selected in
Register 0x5C to Register 0x5E.
TACH Pulses per Revolution Register
Bits [1:0], FAN1 default = 2 pulses per revolution
Bits [3:2], FAN2 default = 2 pulses per revolution
Bits [5:4], FAN3 default = 2 pulses per revolution
Bits [7:6], FAN4 default = 2 pulses per revolution
00 = 1 pulse per revolution
01 = 2 pulses per revolution
10 = 3 pulses per revolution
11 = 4 pulses per revolution
PWM Logic State
The PWM outputs can be programmed high for 100% duty
cycle (noninverted) or low for 100% duty cycle (inverted).
PWM1 Configuration (Register 0x5C)
Bit 4 (INV)
0 = Logic high for 100% PWM duty cycle (noninverted)
1 = Logic low for 100% PWM duty cycle (inverted)
PWM2 Configuration (Register 0x5D)
Bit 4 (INV)
0 = Logic high for 100% PWM duty cycle
1 = Logic low for 100% PWM duty cycle
Rev. 0 | Page 34 of 76
ADT7490
PWM3 Configuration (Register 0x5E)
PWM Configuration Registers
(Register 0x5C to Register 0x5E)
Bit 4 (INV)
Bits [7:5] (BHVR)
0 = Logic high for 100% PWM duty cycle (noninverted).
1 = Logic low for 100% PWM duty cycle (inverted).
111 = manual mode
Low Frequency Mode PWM Drive Frequency
The PWM drive frequency can be adjusted for the application.
Register 0x5F to Register 0x61 configure the PWM frequency
for PWM1 to PWM3, respectively.
PWM1, PWM 2, PWM3 Frequency Registers
(Register 0x5F to Register 0x61)
Once under manual control, each PWM output can be manually updated by writing to Register 0x30 to Register 0x32
(PWMx current duty cycle registers).
Programming the PWM Current Duty Cycle Registers
The PWM current duty cycle registers are 8-bit registers that
allow the PWM duty cycle for each output to be set anywhere
from 0% to 100% in steps of 0.39%. The value to be programmed
into the PWMMIN register is given by
Bits [2:0] FREQ
000 = 11.0 Hz
001 = 14.7 Hz
010 = 22.1 Hz
011 = 29.4 Hz
100 = 35.3 Hz default
101 = 44.1 Hz
110 = 58.8 Hz
111 = 88.2 Hz
Value (decimal) = PWMMIN/0.39
Example 1
For a PWM duty cycle of 50%,
Value (decimal) = 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 0x80 (hex)
Example 2
High Frequency Mode PWM Drive
For a PWM duty cycle of 33%,
Setting Bit 3 of Register 0x5F, Register 0x60, and Register 0x61
enables high frequency mode for Fan 1, Fan 2, and Fan 3,
respectively.
In high frequency mode, the PWM drive frequency is always
22.5 kHz. When high frequency mode is enabled, the dc bits
are automatically asserted internally and do not need to be
changed.
Fan Speed Control
The ADT7490 controls fan speed using automatic and manual
modes.
In automatic fan speed control mode, fan speed is automatically
varied with temperature and without CPU intervention, once
initial parameters are set up. The advantage is that, if the system
hangs, the user is guaranteed that the system is protected from
overheating.
In manual fan speed control mode, the ADT7490 allows the
duty cycle of any PWM output to be manually adjusted. This
can be useful if the user wants to change fan speed in software
or adjust PWM duty cycle output for test purposes. Bits [7:5] of
Register 0x5C to Register 0x5E (PWM Configuration) control
the behavior of each PWM output.
Value (decimal) = 33/0.39 = 85 (decimal)
Value = 85 (decimal) or 0x54 (hex)
PWM Duty Cycle Registers
Register 0x30, PWM1 Duty Cycle = 0xFF (100% default)
Register 0x31, PWM2 Duty Cycle = 0xFF (100% default)
Register 0x32, PWM3 Duty Cycle = 0xFF (100% default)
By reading the PWMx current duty cycle registers, the user can
keep track of the current duty cycle on each PWM output, even
when the fans are running in automatic fan speed control mode
or acoustic enhancement mode.
PROGRAMMING TRANGE
TRANGE defines the distance between TMIN and 100% PWM.
For the ADT7467, ADT7468 and ADT7473, TRANGE is effectively
a slope. For the ADT7475, ADT7476 and ADT7490, TRANGE is
no longer a slope but defines the temperature region where the
PWM output linearly ramps from PWMMIN to 100% PWM.
PWM = 100%
PWMMAX
TRANGE
PWM = 0%
TMIN
Figure 48. TRANGE
Rev. 0 | Page 35 of 76
06789-047
PWMMIN
ADT7490
PROGRAMMING THE AUTOMATIC FAN SPEED CONTROL LOOP
To more efficiently understand the automatic fan speed control
loop, using the ADT7490 evaluation board and software while
reading this section is recommended.
This section provides the system designer with an understanding
of the automatic fan control loop, and provides step-by-step
guidance on effectively evaluating and selecting critical system
parameters. To optimize the system characteristics, the designer
needs to give some thought to system configuration, including
the number of fans, where they are located, and what temperatures are being measured in the particular system.
The mechanical or thermal engineer who is tasked with the
system thermal characterization should also be involved at
the beginning of the system development process.
MANUAL FAN CONTROL OVERVIEW
In unusual circumstances, it can be necessary to manually
control the speed of the fans. Because the ADT7490 has an
SMBus interface, a system can read back all necessary voltage,
fan speed, and temperature information, and use this
information to control the speed of the fans by writing to the
current PWM duty cycle register (0x30, 0x31, and 0x32) of the
appropriate fan. Bits [7:5] of the PWMx configuration registers
(0x5C, 0x5D, and 0x5E) are used to set fans up for manual
control.
THERM OPERATION IN MANUAL MODE
In manual mode, if the temperature increases above the programmed THERM temperature limit, the fans automatically
speed up to maximum PWM or 100% PWM, whichever way
the appropriate fan channel is configured.
Automatic fan speed control reduces acoustic noise by optimizing
fan speed according to accurately measured temperature.
Reducing fan speed can also decrease system current consumption. The automatic fan speed control mode is very flexible due
to the number of programmable parameters, including TMIN and
TRANGE. The TMIN and TRANGE values for a temperature channel
and, therefore, for a given fan are critical, because they define
the thermal characteristics of the system. The thermal validation
of the system is one of the most important steps in the design
process, so these values should be selected carefully.
Figure 49 gives a top-level overview of the automatic fan control
circuitry on the ADT7490. From a systems-level perspective,
up to three system temperatures can be monitored and used to
control three PWM outputs. The three PWM outputs can be
used to control up to four fans. The ADT7490 allows the speed
of four fans to be monitored. Each temperature channel has a
thermal calibration block, allowing the designer to individually
configure the thermal characteristics of each temperature
channel. For example, users can decide to run the CPU fan
when CPU temperature increases above 60°C and a chassis fan
when the local temperature increases above 45°C.
At this stage, the designer has not assigned these thermal
calibration settings to a particular fan drive (PWM) channel.
The right side of Figure 49 shows controls that are fan-specific.
The designer has individual control over parameters such as
minimum PWM duty cycle, fan speed failure thresholds, and
even ramp control of the PWM outputs. Automatic fan control
ultimately allows graceful fan speed changes that are less
perceptible to the system user.
AUTOMATIC FAN CONTROL OVERVIEW
The ADT7490 can automatically control the speed of fans based
on the measured temperature. This is done independently of
CPU intervention once the initial parameters are set up.
The ADT7490 has a local temperature sensor and two remote
temperature channels that can be connected to a CPU on-chip
thermal diode (available on Intel Pentium® class and other
CPUs). These three temperature channels can be used as the
basis for automatic fan speed control to drive fans using pulsewidth modulation (PWM).
Rev. 0 | Page 36 of 76
ADT7490
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 1 =
AMBIENT TEMP
TRANGE
THERMAL CALIBRATION
0%
TACHOMETER 1
MEASUREMENT
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
TACH1
CPU FAN SINK
PWM
MIN
PWM
CONFIG
0%
PWM
GENERATOR
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
REMOTE 2 =
GPU TEMP
TRANGE
THERMAL CALIBRATION
PWM
MIN
0%
PWM
CONFIG
PWM
GENERATOR
100%
TRANGE
TACH2
FRONT CHASSIS
TACHOMETER 3
AND 4
MEASUREMENT
TMIN
PWM2
100%
TACHOMETER 2
MEASUREMENT
TMIN
PWM1
100%
MUX
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM3
TACH3
0%
REAR CHASSIS
PECI =
CPU TEMP
06789-067
THERMAL CALIBRATION
Figure 49. Automatic Fan Control Block Diagram
4.
STEP 1: HARDWARE CONFIGURATION
During system design, the motherboard sensing and control
capabilities should be addressed early in the design stages.
Decisions about how these capabilities are used should involve
the system thermal/mechanical engineer. Ask the following
questions:
1.
This influences the assignment of the temperature measurement channels to particular system thermal zones. For
example, locating the ADT7490 close to the VRM controller
circuitry allows the VRM temperature to be monitored using
the local temperature channel.
What ADT7490 functionality is used?
•
•
•
PWM2 or SMBALERT?
TACH4 fan speed measurement or overtemperature
THERM function?
2.5 VIN voltage monitoring or overtemperature
THERM function?
The ADT7490 offers multifunctional pins that can be
reconfigured to suit different system requirements and
physical layouts. These multifunction pins are software
programmable.
2.
How many fans are supported in the system, three or four?
This influences the choice of whether to use the TACH4
pin or to reconfigure it for the THERM function.
3.
Is the CPU fan to be controlled using the ADT7490, or will
the CPU fan run at full speed 100% of the time?
If run at 100%, it frees up a PWM output, but the system is
louder.
Where is the ADT7490 going to be physically located in
the system?
STEP 2: CONFIGURING THE MUXTIPLEXER
After the system hardware configuration is determined, the fans
can be assigned to particular temperature channels. Not only
can fans be assigned to individual channels, but the behavior
of the fans is also configurable. For example, fans can be run
under automatic fan control, can be run manually (under
software control), or can be run at the fastest speed calculated by multiple temperature channels. The mux is the bridge
between temperature measurement channels and the three
PWM outputs.
Bits [7:5] (BHVR) of Register 0x5C, Register 0x5D, and Register
0x5E (PWM configuration registers) control the behavior of the
fans connected to the PWM1, PWM2, and PWM3 outputs,
respectively. The values selected for these bits determine how
the multiplexer connects a temperature measurement channel
to a PWM output.
Rev. 0 | Page 37 of 76
ADT7490
Automatic Fan Control Multiplexer Options
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and Register
0x5E, with the ALT bit (Bit 3) cleared to 0.
000 = Remote 1 temperature controls PWMx
001 = Local temperature controls PWMx
010 = Remote 2 temperature controls PWMx
101 = Fastest speed calculated by local and Remote 2
temperature controls PWMx
110 = Fastest speed calculated by all three temperature
channels controls PWMx
The fastest speed calculated options pertain to controlling
one PWM output based on multiple temperature channels.
The thermal characteristics of the three temperature zones
can be set to drive a single fan. An example is the fan turning
on when Remote 1 temperature exceeds 60°C or if the local
temperature exceeds 45°C.
Setting the ALT bit in Register 0x5C, Register 0x5D, and
Register 0x5E gives alternative behavior settings for Bits [7:5]
of the PWM configuration registers.
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and Register
0x5E, with the ALT bit (Bit 3) set to 1.
000 = PECI0 reading controls PWMx
001 = PECI1 reading controls PWMx
010 = PECI2 reading controls PWMx
011 = PECI3 reading controls PWMx
101 = Fastest speed calculated by all four PECI readings
controls PWMx
111 = Fastest speed calculated by all thermal zones (Local,
Rem1, Rem2 and PECI) controls PWMx
STEP 3: TMIN SETTINGS FOR THERMAL
CALIBRATION CHANNELS
TMIN is the temperature at which the fans start to turn on under
automatic fan control. The speed at which the fan runs at TMIN
is programmed later. The TMIN values chosen are temperature
channel specific, for example, 25°C for ambient channel, 30°C
for VRM temperature, and 40°C for processor temperature.
TMIN is an 8-bit value, either twos complement or Offset 64,
that can be programmed in 1°C increments. A TMIN register
is associated with each temperature measurement channel:
Remote 1, local, Remote 2 and PECI temperature. When the
TMIN value is exceeded, the fan turns on and runs at the minimum PWM duty cycle. The fan turns off once the temperature
has dropped below TMIN − THYST.
To overcome fan inertia, the fan is spun up until two valid TACH
rising edges are counted. See the Fan Start-Up Timeout section
for more details. In some cases, primarily for psycho-acoustic
reasons, it is desirable that the fan never switch off below TMIN.
When set, Bits [7:5] of Enhanced Acoustics Register 1 (0x62)
keep the fans running at the PWM minimum duty cycle, if the
temperature should fall below TMIN.
TMIN Registers
Register 0x67, Remote 1 Temperature TMIN = 0x5A (90°C default)
Register 0x68, Local Temperature TMIN = 0x5A (90°C default)
Register 0x69, Remote 2 Temperature TMIN = 0x5A (90°C default)
Register 0x3B, PECI TMIN = 0xE0 (−32°C default)
Enhanced Acoustics Register 1 (Register 0x62)
Other Mux Options
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below TMIN – THYST.
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and Register
0x5E, with the ALT bit (Bit 3) cleared to 0.
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle
below TMIN – THYST.
011 = PWMx runs full speed
100 = PWMx disabled (default)
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
temperature is below TMIN – THYST.
111 = Manual mode. PWMx is running under software
control. In this mode, PWM duty cycle registers
(Register 0x30 to Register 0x32) are writable and control
the PWM outputs.
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle
below TMIN – THYST.
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and Register
0x5E, with ALT bit (Bit 3) set to 1.
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below TMIN – THYST.
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle
below TMIN – THYST.
100 = PWMx runs at 100% duty cycle
110 = PWMx runs at 100% duty cycle
Rev. 0 | Page 38 of 76
ADT7490
PWM DUTYCYCLE
100%
0%
TMIN
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
PWM
CONFIG
TRANGE
0%
TACHOMETER 3
AND 4
MEASUREMENT
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
Figure 50. Understanding the TMIN Parameter
Rev. 0 | Page 39 of 76
06789-068
THERMAL CALIBRATION
ADT7490
STEP 4: PWMMIN FOR EACH PWM (FAN) OUTPUT
Example 1
PWMMIN is the minimum PWM duty cycle at which each fan
in the system runs. It is also the start speed for each fan under
automatic fan control once the temperature rises above TMIN.
For maximum system acoustic benefit, PWMMIN should be as
low as possible. Depending on the fan used, the PWMMIN setting is usually in the 20% to 33% duty cycle range. This value
can be found through fan validation.
For a minimum PWM duty cycle of 50%,
For a minimum PWM duty cycle of 33%,
Value (decimal) = 33/0.39 = 85 (decimal)
Value = 85 (decimal) or 0x54 (hex)
PWMMIN Registers
Register 0x64, PWM1 Minimum Duty Cycle = 0x80 (50% default)
Register 0x65, PWM2 Minimum Duty Cycle = 0x80 (50% default)
Register 0x66, PWM3 Minimum Duty Cycle = 0x80 (50% default)
Note on Fan Speed and PWM Duty Cycle
PWMMIN
TEMPERATURE
TMIN
06789-055
0%
Figure 51. PWMMIN Determines Minimum PWM Duty Cycle
More than one PWM output can be controlled from a single
temperature measurement channel. For example, Remote 1
Temperature can control PWM1 and PWM2 outputs. If two
different fans are used on PWM1 and PWM2, the fan
characteristics can be set up differently. As a result, Fan 1 driven
by PWM1 can have a different PWMMIN value than that of Fan 2
connected to PWM2. Figure 52 illustrates this as PWM1MIN
(front fan) turned on at a minimum duty cycle of 20%, while
PWM2MIN (rear fan) is turned on at a minimum of 40% duty
cycle. Note that both fans turn on at exactly the same
temperature, defined by TMIN.
100%
P
% fanspeed = PWM Duty Cycle × 10
STEP 5: PWMMAX FOR PWM (FAN) OUTPUTS
PWMMAX is the maximum duty cycle that each fan in the system
runs at under the automatic fan speed control loop. For maximum system acoustic benefit, PWMMAX should be as low as
possible, but should be capable of maintaining the processor
temperature limit at an acceptable level. If the THERM
temperature limit is exceeded, the fans are still boosted to
100% for fail-safe cooling.
There is a PWMMAX limit for each fan channel. The default
value of this register is 0xFF and has no effect unless it is
programmed.
2
WM
PW
PWM2MIN
The PWM duty cycle does not directly correlate to fan speed in
RPM. Running a fan at 33% PWM duty cycle does not equate to
running the fan at 33% speed. Driving a fan at 33% PWM duty
cycle actually runs the fan at closer to 50% of its full speed. This
is because fan speed in %RPM generally relates to the square
root of PWM duty cycle. Given a PWM square wave as the
drive signal, fan speed in RPM approximates to
M1
100%
PWM1MIN
TMIN
TEMPERATURE
06789-056
0%
Figure 52. Operating Two Different Fans from a Single Temperature Channel
Programming the PWMMIN Registers
The PWMMIN registers are 8-bit registers that allow the minimum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the minimum
PWM duty cycle to be set in steps of 0.39%.
The value to be programmed into the PWMMIN register is
given by
Value (decimal) = PWMMIN/0.39
Rev. 0 | Page 40 of 76
PWMMAX
PWMMIN
0%
TMIN
TEMPERATURE
Figure 53. PWMMAX Determines Maximum PWM Duty Cycle
Below the THERM Temperature Limit
06789-057
PWM DUTY CYCLE
Example 2
PWM DUTY CYCLE
PWM DUTY CYCLE
100%
Value (decimal) = 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 0x80 (hex)
ADT7490
Programming the PWMMAX Registers
The PWMMAX registers are 8-bit registers that allow the
maximum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the maximum PWM
duty cycle to be set in steps of 0.39%.
case operating points. For example, 70°C is reached when
the fans are running at 50% PWM duty cycle.
3.
Determine the slope of the required control loop to meet
these requirements.
4.
Using the ADT7490 evaluation software, graphically
program and visualize this functionality. Ask a local
Analog Devices representative for details.
The value to be programmed into the PWMMAX register is
given by
Value (decimal) = PWMMAX/0.39
As PWMMIN is changed, the automatic fan control slope changes.
Example 1
100%
PWM DUTY CYCLE
For a maximum PWM duty cycle of 50%,
Value (decimal) – 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 0x80 (hex)
Example 2
For a minimum PWM duty cycle of 75%,
Value (decimal) = 75/0.39 = 85 (decimal)
50%
33%
0%
Value = 192 (decimal) or 0xC0 (hex)
TMIN
Register 0x38, Maximum PWM1 Duty Cycle = 0xFF
(100% default)
Figure 55. Adjusting PWMMIN Changes the Automatic Fan Control Slope
As TRANGE is changed, the slope changes. As TRANGE gets smaller,
the fans reach 100% speed with a smaller temperature change.
Register 0x39, Maximum PWM2 Duty Cycle = 0xFF
(100% default)
Register 0x3A, Maximum PWM3 Duty Cycle = 0xFF
(100% default)
10%
0%
TMIN–HYST
TRANGE
TMIN
Figure 56. Increasing TRANGE Changes the AFC slope
100%
PWM DUTY CYCLE
PWMMIN
TMIN
TEMPERATURE
06789-058
0%
MAX
PWM
10%
Figure 54. TRANGE Parameter Affects Cooling Slope
0%
The TRANGE is determined by the following procedure:
2.
Determine the maximum operating temperature for that
channel (for example, 70°C).
Determine experimentally the fan speed (PWM duty cycle
value) that does not exceed the temperature at the worstRev. 0 | Page 41 of 76
TRANGE
TMIN–HYST
06789-061
PWM DUTY CYCLE
100%
30°C
40°C
45°C
54°C
06789-060
TRANGE is the range of temperature over which automatic fan
control occurs once the programmed TMIN temperature has
been exceeded. TRANGE is the temperature range between PWMMIN
and 100% PWM where the fan speed changes linearly. Otherwise
stated, it is the line drawn between the TMIN/PWMMIN and the
(TMIN + TRANGE)/100% PWM intersection points.
PWM DUTY CYCLE
100%
STEP 6: TRANGE FOR TEMPERATURE CHANNELS
1.
06789-059
30°C
PWMMAX Registers
Figure 57. Changing PWM Max Does Not Change the AFC Slope
ADT7490
Selecting TRANGE
The TRANGE value can be selected for each temperature channel:
Remote 1, local, Remote 2, and PECI temperature. Bits [7:4]
(TRANGE) of Register 0x5F to Register 0x61 and Register 0x3C
define the TRANGE value for each temperature channel.
Table 23. Selecting a TRANGE Value
Figure 58 shows PWM duty cycle vs. temperature for each
TRANGE setting. Figure 58B shows how each TRANGE setting affects
fan speed vs. temperature. As can be seen from the graph, the
effect on fan speed is nonlinear.
100
2°C
2.5°C
90
3.33°C
80
4°C
5°C
70
6.67°C
60
8°C
10°C
50
13.3°C
16°C
40
20°C
30
26.6°C
32°C
20
40°C
10
0
0
Register 0x5F configures Remote 1 TRANGE; Register 0x60 configures local
TRANGE; Register 0x61 configures Remote 2 TRANGE, Register 0x3C configures
PECI TRANGE.
53.3°C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
(A)
100
Actual Changes in PWM Output (Advanced Acoustics
Settings)
2°C
2.5°C
90
3.33°C
FAN SPEED (% OF MAX)
80
While the automatic fan control algorithm describes the general
response of the PWM output, it is also necessary to note that
the enhanced acoustics registers (0x62, 0x63, and 0x3C) can be
used to set/clamp the maximum rate of change of PWM output
for a given temperature zone. This means that if TRANGE is programmed with an AFC slope that is quite steep, a relatively
small change in temperature could cause a large change in
PWM output and possibly an audible change in fan speed,
which can be noticeable/annoying to end users.
80°C
4°C
5°C
70
6.67°C
60
8°C
10°C
50
13.3°C
16°C
40
20°C
30
26.6°C
32°C
20
40°C
10
0
0
53.3°C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
80°C
(B)
Figure 58. TRANGE vs. Actual Fan Speed (Not PWM Drive) Profile
The graphs in Figure 58 assume the fan starts from 0% PWM
duty cycle. Clearly, the minimum PWM duty cycle, PWMMIN,
needs to be factored in to see how the loop actually performs
in the system. Figure 59 shows how TRANGE is affected when
the PWMMIN value is set to 20%. It can be seen that the fan
actually runs at about 45% fan speed when the temperature
exceeds TMIN.
Rev. 0 | Page 42 of 76
06789-062
1
TRANGE (°C)
2
2.5
3.33
4
5
6.67
8
10
13.33
16
20
26.67
32 (default)
40
53.33
80
PWM DUTY CYCLE (%)
Bits [7:4]1
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Decreasing the speed of the PWM output changes by
programming the smoothing on the appropriate temperature
channels (Register 0x62 and Register 0x63) changes how fast
the fan speed increases/decreases in the event of a temperature
spike. Slowly the PWM duty cycle increases until the PWM
duty cycle reaches the appropriate duty cycle as defined by the
AFC curve.
ADT7490
100
2°C
3.33°C
4°C
PWM DUTY CYCLE (%)
80
5°C
70
Note that TTHERM limits are nonmaskable and affect the fan speed
no matter how automatic fan control settings are configured.
This allows some flexibility, because a TRANGE value can be selected
based on its slope, while a hard limit (such as 70°C), can be
programmed as TMAX (the temperature at which the fan reaches
full speed) by setting TTHERM to that limit (for example, 70°C).
6.67°C
8°C
60
10°C
50
13.3°C
16°C
40
20°C
30
26.6°C
32°C
20
THERM Registers
40°C
10
0
0
effects. Ultimately, this limit should be set up as a fail-safe, and
one should ensure that it is not exceeded under normal system
operating conditions.
2.5°C
90
53.3°C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
Register 0x6A, Remote 1 THERM Temperature Limit = 0x64
(100°C default)
80°C
(A)
100
2.5°C
90
4°C
5°C
70
Register 0x3D, PECI TCONTROL Limit = 0x00 (0°C default)
6.67°C
60
8°C
THERM Hysteresis
10°C
50
THERM hysteresis on a particular channel is configured via the
hysteresis settings in the following section (0x6D and 0x6E).
For example, setting hysteresis on the Remote 1 channel also
sets the hysteresis on Remote 1 THERM.
13.3°C
40
16°C
20°C
30
26.6°C
20
32°C
40°C
10
Hysteresis Registers
53.3°C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
80°C
(B)
Register 0x6D, Remote 1, Local Hysteresis Register
06789-063
FAN SPEED (% OF MAX)
Register 0x6C, Remote 2 THERM Temperature limit = 0x64
(100°C default)
3.33°C
80
0
0
Register 0x6B, Local THERM Temperature Limit = 0x64 (100°C
default)
2°C
Bits [7:4], Remote 1 Temperature hysteresis (4°C default).
Bits [3:0], Local Temperature hysteresis (4°C default).
Figure 59. TRANGE and % Fan Speed Slopes with PWMMIN = 20%
Register 0x6E, Remote 2, PECI Temperature Hysteresis Register
STEP 7: TTHERM FOR TEMPERATURE CHANNELS
TTHERM is the absolute maximum temperature allowed on a
temperature channel. For PECI temperature channels, the
equivalent parameter is TCONTROL. Above this temperature, a
component such as the CPU or VRM may be operating beyond
its safe operating limit. When the temperature measured
exceeds TTHERM, all fans are driven at 100% PWM duty cycle
(full speed) to provide critical system cooling.
The fans remain running at 100% until the temperature drops
below TTHERM minus hysteresis, where hysteresis is the number
programmed into the hysteresis registers (0x6D and 0x6E). The
default hysteresis value is 4°C.
Bits [7:4], Remote 2 Temperature hysteresis (4°C default).
Bits [3:0], PECI Temperature hysteresis (4°C default).
Because each hysteresis setting is four bits, hysteresis values
are programmable from 1°C to 15°C. It is not recommended
that hysteresis values ever be programmed to 0°C, because this
disables hysteresis. In effect, this causes the fans to cycle (during
a THERM event) between normal speed and 100% speed, or,
while operating close to TMIN, between normal speed and off,
creating unsettling acoustic noise.
The TTHERM limit should be considered the maximum worst-case
operating temperature of the system. Because exceeding any
TTHERM limit runs all fans at 100%, it has very negative acoustic
Rev. 0 | Page 43 of 76
ADT7490
TRANGE
PWM DUTYCYCLE
100%
0%
TMIN
TTHERM
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
06789-065
THERMAL CALIBRATION
Figure 60. How TTHERM Relates to Automatic Fan Control
STEP 8: THYST FOR TEMPERATURE CHANNELS
THYST is the amount of extra cooling a fan provides after the
temperature measured has dropped back below TMIN before the
fan turns off. The premise for temperature hysteresis (THYST) is
that, without it, the fan would merely chatter, or cycle on and
off regularly, whenever the temperature is hovering at about the
TMIN setting.
The THYST value chosen determines the amount of time needed
for the system to cool down or heat up as the fan is turning on
and off. Values of hysteresis are programmable in the range of
1°C to 15°C. Larger values of THYST prevent the fans from
chattering on and off. The THYST default value is set at 4°C.
The THYST setting applies not only to the temperature hysteresis
for fan on/off, but the same setting is used for the TTHERM hysteresis
value, described in the Step 7: TTHERM for Temperature Channels
section. Therefore, programming Register 0x6D and Register
0x6E sets the hysteresis for both fan on/off and the THERM
function.
In some applications, it is required that fans not turn off below
TMIN, but remain running at PWMMIN. Bits [7:5] of Enhanced
Acoustics Register 1 (0x62) allow the fans to be turned off or to
be kept spinning below TMIN. If the fans are always on, the THYST
value has no effect on the fan when the temperature drops
below TMIN.
Rev. 0 | Page 44 of 76
ADT7490
TRANGE
PWM DUTYCYCLE
100%
0%
TTHERM
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
PWM
CONFIG
TRANGE
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
06789-066
TMIN
Figure 61. The THYST Value Applies to Fan On/Off Hysteresis and THERM Hysteresis
THERM Hysteresis
Configuration Register 6 (Register 0x10)
Any hysteresis programmed via Register 0x6D and Register 0x6E
also applies hysteresis on the appropriate THERM channel.
Bit 0 (SLOW) = 1, slows the ramp rate for PWM changes
associated with the Remote 1 temperature channel by 4.
Enhanced Acoustics Register 1 (Register 0x62)
Bit 1 (SLOW) = 1, slows the ramp rate for PWM changes
associated with the local temperature channel by 4.
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle
below TMIN − THYST.
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle
below TMIN − THYST.
Bit 2 (SLOW) = 1, slows the ramp rate for PWM changes
associated with the Remote 2 temperature channel by 4.
Bit 7 (ExtraSlow) = 1, slows the ramp rate for all fans by a factor
of 39.2%.
The following sections list the ramp-up times when the
SLOW bit is set for each temperature monitoring channel.
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle
below TMIN − THYST.
Rev. 0 | Page 45 of 76
ADT7490
Enhanced Acoustics Register 1 (Register 0x62)
PROGRAMMING THE GPIOs
Bits [2:0] ACOU, selects the ramp rate for PWM outputs
associated with the Remote Temperature 1 input.
The ADT7490 has two dedicated GPIOs (Pin 5 and Pin 6).The
direction (input or output) and polarity (active high or active
low) of the GPIOs is set in the GPIO Configuration Register
(0x80). Bit 2 and Bit 3 of Register 0x80 also reflect the state of
the GPIO pins when configured as inputs and assert the GPIO
pins when configured as outputs.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
XNOR TREE TEST MODE
Enhanced Acoustics Register 2 (Register 0x63)
The ADT7490 includes an XNOR tree test mode. This mode
is useful for in-circuit test equipment at board-level testing. By
applying stimulus to the pins included in the XNOR tree, it is
possible to detect opens, or shorts, on the system board.
Bits [2:0] ACOU3, selects the ramp rate for PWM outputs
associated with the local temperature channel.
The XNOR tree test is invoked by setting Bit 0 (XEN) of the
XNOR Tree Test Enable register (Register 0x6F).
Figure 62 shows the signals that are exercised in the XNOR tree
test mode.
PWM2
PWM3
TACH1
TACH2
[6:4] ACOU2, selects the ramp rate for PWM outputs
associated with the Remote Temperature 2 input.
TACH3
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
When Bit 7 of Configuration Register 6 (0x10) = 1, the
preceding ramp rates change to
000 = 52.2 sec
001 = 26.1 sec
010 = 17.4 sec
011 = 10.4 sec
100 = 6.5 sec
101 = 4.4 sec
110 = 2.2 sec
111 = 1.1 sec
TACH4
PWM1/XTO
Figure 62. XNOR Tree Test
Setting the appropriate SLOW Bit 2, Bit 1, or Bit 0 of
Configuration Register 6 (0x10) slows the ramp rate
further by a factor of 4.
Rev. 0 | Page 46 of 76
06789-004
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
ADT7490
REGISTER TABLES
Table 24. ADT7490 Registers
Addr.
0x10
R/W
R/W
Description
Config. 6
Bit 7
ExtraSlow
Bit 5
Res
Bit 4
Res
Bit 3
Res
RES
7
7
7
9
9
IMON
Bit 6
VCCP
Low
RES
6
6
6
8
8
IMON
Bit 1
SLOW
Local
FSPD
1
1
1
3
3
RES
Bit 0
SLOW
Remote 1
THERMHys
0
0
0
2
2
RES
Default
0x00
Lockable?
Yes
FSPDIS
3
3
3
5
5
RES
Bit 2
SLOW
Remote 2
Vx1
2
2
2
4
4
RES
0x11
0x1A
0x1B
0x1C
0x1D
0x1E
0x1F
R/W
R
R
R
R
R
R
0x20
0x21
0x22
0x23
0x24
0x25
R
R
R
R
R
R
0x26
0x27
R
R
0x28
R
0x29
R
0x2A
R
0x2B
R
0x2C
R
0x2D
R
0x2E
R
0x2F
R
0x30
R/W
0x31
R/W
0x32
R/W
0x33
0x34
R
R/W
0x35
R/W
0x36
R/W
0x38
R/W
0x39
R/W
0x3A
R/W
0x3B
R/W
Config. 7
PECI1
PECI2
PECI3
IMON Meas.
VTT Meas.
Extended
Resolution 3
+2.5VIN Meas.
VCCP Meas.
VCC Meas.
+5VIN Meas.
+12VIN Meas.
Remote 1
Temp.
Local Temp.
Remote 2
Temp.
TACH1 Low
Byte
TACH1 High
Byte
TACH2 Low
Byte
TACH2 High
Byte
TACH3 Low
Byte
TACH3 High
Byte
TACH4 Low
Byte
TACH4 High
Byte
PWM1
Current Duty
Cycle
PWM2
Current Duty
Cycle
PWM3
Current Duty
Cycle
PECI0
PECI Low
Limit
PECI High
Limit
PECI Config.
Register 1
Max PWM1
Duty Cycle
Max PWM2
Duty Cycle
Max PWM3
Duty Cycle
PECI TMIN
RES
5
5
5
7
7
VTT
TODIS
4
4
4
6
6
VTT
0x00
0x80
0x80
0x80
0x00
0x00
0x00
Yes
9
9
9
9
9
9
8
8
8
8
8
8
7
7
7
7
7
7
6
6
6
6
6
6
5
5
5
5
5
5
4
4
4
4
4
4
3
3
3
3
3
3
2
2
2
2
2
2
0x00
0x00
0x00
0x00
0x00
0x80
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
0x80
0x80
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0xFF
7
6
5
4
3
2
1
0
0xFF
7
6
5
4
3
2
1
0
0xFF
7
7
6
6
5
5
4
4
3
3
2
2
1
1
0
0
0x80
0x81
7
6
5
4
3
2
1
0
0x00
RES
RES
RES
REPLACE
DOM0
AVG2
AVG1
AVG0
0x00
Yes
7
6
5
4
3
2
1
0
0xFF
Yes
7
6
5
4
3
2
1
0
0xFF
Yes
7
6
5
4
3
2
1
0
0xFF
Yes
7
6
5
4
3
2
1
0
0xE0
Yes
Rev. 0 | Page 47 of 76
ADT7490
Addr.
0x3C
R/W
R/W
Description
PECI TRANGE/
Enhanced
Acoustics
PECI TCONTROL
Company
ID No.
Version/
Revision
Config.
Register 1
Bit 7
RANGE
Bit 6
RANGE
Bit 5
RANGE
Bit 4
RANGE
Bit 3
ENP
Bit 2
ACOU
Bit 1
ACOU
Bit 0
ACOU
Default
0xC0
Lockable?
Yes
0x3D
0x3E
R/W
R
7
7
6
6
5
5
4
4
3
3
2
2
1
1
0
0
0x00
0x41
Yes
0x3F
R
VER3
VER2
VER1
VER0
4-Wire
PECI
REV1
REV0
0x6E
0x40
R/W
RES
RES
PECI
Monitor
Fan Boost
RDY
LOCK
STRT
0x04
R
Interrupt
Status 1
OOL
R2T
THERM
in
Manual
LT
0x41
R1T
+5VIN
VCC
VCCP
+2.5VIN/
THERM
0x00
0x42
R
Interrupt
Status 2
D2 FAULT
D1
FAULT
FAN4/
THERM
FAN3
FAN2
FAN1
OOL
+12VIN
0x00
0x43
R
Interrupt
Status 3
OOL
RES
RES
RES
COMM
DATA
PECI0
0x00
0x44
R/W
7
6
5
4
2
1
0
0x00
0x45
R/W
7
6
5
4
3
2
1
0
0xFF
0x46
R/W
7
6
5
4
3
2
1
0
0x00
0x47
R/W
7
6
5
4
3
2
1
0
0xFF
0x48
R/W
7
6
5
4
3
2
1
0
0x00
0x49
R/W
7
6
5
4
3
2
1
0
0xFF
0x4A
R/W
7
6
5
4
3
2
1
0
0x00
0x4B
R/W
7
6
5
4
3
2
1
0
0xFF
0x4C
R/W
7
6
5
4
3
2
1
0
0x00
0x4D
R/W
7
6
5
4
3
2
1
0
0xFF
0x4E
R/W
7
6
5
4
3
2
1
0
0x81
0x4F
R/W
7
6
5
4
3
2
1
0
0x7F
0x50
R/W
7
6
5
4
3
2
1
0
0x81
0x51
R/W
7
6
5
4
3
2
1
0
0x7F
0x52
R/W
7
6
5
4
3
2
1
0
0x81
0x53
R/W
7
6
5
4
3
2
1
0
0x7F
0x54
R/W
7
6
5
4
3
2
1
0
0xFF
0x55
R/W
15
14
13
12
11
10
9
8
0xFF
0x56
R/W
7
6
5
4
3
2
1
0
0xFF
0x57
R/W
15
14
13
12
11
10
9
8
0xFF
0x58
R/W
7
6
5
4
3
2
1
0
0xFF
0x59
R/W
+2.5VIN
Low Limit
+2.5VIN
High Limit
VCCP
Low Limit
VCCP
High Limit
VCC
Low Limit
VCC
High Limit
+5VIN
Low Limit
+5VIN
High Limit
+12VIN
Low Limit
+12VIN
High Limit
Remote 1
Temp Low
Limit
Remote 1
Temp High
Limit
Local Temp
Low Limit
Local Temp
High Limit
Remote 2
Temp Low
Limit
Remote 2
Temp High
Limit
TACH1 Min
Low Byte
TACH1 Min
High Byte
TACH2 Min
Low Byte
TACH2 Min
High Byte
TACH3 Min
Low Byte
TACH3 Min
High Byte
OVT
(THERM
Temp Limit)
3
15
14
13
12
11
10
9
8
0xFF
Rev. 0 | Page 48 of 76
Yes
ADT7490
Addr.
0x5A
R/W
R/W
0x5B
R/W
0x5C
R/W
0x5D
R/W
0x5E
R/W
0x5F
R/W
0x60
R/W
0x61
R/W
0x62
R/W
0x63
R/W
0x64
R/W
0x65
R/W
0x66
R/W
0x67
R/W
0x68
R/W
0x69
R/W
0x6A
R/W
0x6B
R/W
0x6C
R/W
0x6D
R/W
0x6E
R/W
0x6F
R/W
0x70
R/W
0x71
R/W
0x72
R/W
0x73
0x74
R/W
R/W
Description
TACH4 Min
Low Byte
TACH4 Min
High Byte
PWM1
Config.
Register
PWM2
Config.
Register
PWM3
Config.
Register
Remote 1
TRANGE/PWM1
Frequency
Local
TRANGE/PWM2
Frequency
Remote 2
TRANGE/PWM3
Frequency
Enhanced
Acoustics
Reg. 1
Enhanced
Acoustics
Reg. 2
PWM1 Min
Duty Cycle
PWM2 Min
Duty Cycle
PWM3 Min
Duty Cycle
Remote 1
Temp TMIN
Local Temp.
TMIN
Remote 2
Temp TMIN
Remote 1
THERM Temp
Limit
Local THERM
Temp. Limit
Remote 2
THERM Temp
Limit
Remote 1
and Local
Temp/TMIN
Hysteresis
Remote 2
and PECI
Temp/TMIN
Hysteresis
XNOR Tree
Test Enable
Remote 1
Temp Offset
Local Temp
Offset
Remote 2
Temp Offset
Config. Reg. 2
Interrupt
Mask Reg. 1
Bit 7
7
Bit 6
6
Bit 5
5
Bit 4
4
Bit 3
3
Bit 2
2
Bit 1
1
Bit 0
0
Default
0xFF
15
14
13
12
11
10
9
8
0xFF
BHVR
BHVR
BHVR
INV
ALT
SPIN
SPIN
SPIN
0x62
Yes
BHVR
BHVR
BHVR
INV
ALT
SPIN
SPIN
SPIN
0x62
Yes
BHVR
BHVR
BHVR
INV
ALT
SPIN
SPIN
SPIN
0x62
Yes
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0xC4
Yes
MIN3
MIN2
MIN1
SYNC
EN1
ACOU
ACOU
ACOU
0x00
Yes
EN2
ACOU2
ACOU2
ACOU2
EN3
ACOU3
ACOU3
ACOU3
0x00
Yes
7
6
5
4
3
2
1
0
0x80
Yes
7
6
5
4
3
2
1
0
0x80
Yes
7
6
5
4
3
2
1
0
0x80
Yes
7
6
5
4
3
2
1
0
0x5A
Yes
7
6
5
4
3
2
1
0
0x5A
Yes
7
6
5
4
3
2
1
0
0x5A
Yes
7
6
5
4
3
2
1
0
0x64
Yes
7
6
5
4
3
2
1
0
0x64
Yes
7
6
5
4
3
2
1
0
0x64
Yes
HYSR1
HYSR1
HYSR1
HYSR1
HYSL
HYSL
HYSL
HYSL
0x44
Yes
HYSR2
HYSR2
HYSR2
HYSR2
HYSP
HYSP
HYSP
HYSP
0x44
Yes
RES
RES
RES
RES
RES
RES
RES
XEN
0x00
Yes
7
6
5
4
3
2
1
0
0x00
Yes
7
6
5
4
3
2
1
0
0x00
Yes
7
6
5
4
3
2
1
0
0x00
Yes
Shutdown
OOL
CONV
R2T
ATTN
LT
AVG
RIT
Fan3Detect
+5VIN
Fan2Detect
VCC
Fan1Detect
VCCP
FanPresDT
+2.5VIN/
THERM
0x00
0x00
Yes
Rev. 0 | Page 49 of 76
Lockable?
ADT7490
Addr.
0x75
R/W
R/W
Description
Interrupt
Mask Reg. 2
Bit 7
D2 Fault
Bit 6
D1
Fault
Bit 5
FAN4/
THERM
Bit 4
FAN3
Bit 3
FAN2
Bit 2
FAN1
Bit 1
OOL
Bit 0
+12VIN/
VC
Default
0x00
0x76
R
+5VIN
+5VIN
VCC
VCC
VCCP
VCCP
+2.5VIN
+2.5VIN
0x00
0x77
R
TDM2
TDM2
LTMP
LTMP
TDM1
TDM1
+12VIN
+12VIN
0x00
0x78
R/W
Extended
Resolution 1
Extended
Resolution 2
Config. 3
DC4
DC3
DC2
DC1
FAST
BOOST
ALERT
Enable
0x00
0x79
R
TMR
TMR
TMR
TMR
TMR
TMR
ASRT/
TMR0
0x00
0x7A
R/W
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
LIMT
0x00
0x7B
R/W
FAN4
FAN4
FAN3
FAN3
FAN2
FAN2
FAN1
FAN1
0x55
0x7C
R/W
THERM Timer
Status
THERM Timer
Limit
TACH Pulses
per
Revolution
Config.
Register 5
THERM/
+2.5VIN
TMR
R2 THERM
Output
Only
Temp
Offset
TWOS
COMPL
0x01
Yes
Config.
Register 4
BpAtt
+12VIN
PECI R1
THERM
Output
Only
BpAtt
+2.5VIN
RES
R/W
R1
THERM
Output
Only
BpAtt
VCCP
RES
0x7D
Local
THERM
Output
Only
BpAtt
+5VIN
Pin 14
Func
Pin 14
Func
0x00
Yes
0x7E
0x7F
0x80
R
R
R/W
Yes
Yes
0x81
R
0x82
R/W
0x83
R/W
0x84
0x85
0x86
0x87
R/W
R/W
R/W
R/W
0x88
0x89
0x8A
R/W
R
R/W
0x8B
R/W
0x8C
R/W
0x8D
R/W
0x8E
R/W
0x8F
R/W
0x90
R/W
0x94
R/W
0x95
R/W
0x96
R/W
0x97
R/W
Test 1
Test 2
GPIO Config.
Register
Interrupt
Status 4
Interrupt
Mask 3
Interrupt
Mask 4
VTT Low Limit
IMON Low Limit
VTT High Limit
IMON High
Limit
PECI Config. 2
TEST 3
PECI
Operating
Point
Remote 1
Operating
Point
Local Temp
Operating
Point
Remote 2
Operating
Point
Dynamic
TMIN Control
Reg. 1
Dynamic
TMIN Control
Reg. 2
Dynamic TMIN
Control Reg. .3
PECI0 Temp
Offset
PECI1 Temp
Offset
PECI2 Temp
Offset
PECI3 Temp
Offset
Yes
VTT
GPIO2
DIR
IMON
GPIO1
POL
PECI3
THERM
Disable
Do not write to this register
Do not write to this register
GPIO1
GPIO2
GPIO2
POL
PECI2
PECI1
RES
OOL
RES
RES
RES
OVT
COMM
DATA
PECI0
0x00
VTT
IMON
PECI3
PECI2
PECI1
RES
RES
RES
0x00
7
7
7
7
6
6
6
6
5
5
5
5
4
4
4
4
3
3
3
3
2
2
2
2
1
1
1
1
0
0
0
0
0x00
0x00
0xFF
0xFF
Yes
Yes
Yes
Yes
#CPU
#CPU
DOM1
RES
RES
7
6
5
DOM2
DOM3
RES
Do not write to this register
4
3
2
1
0
0x00
0x00
0xFB
Yes
Yes
Yes
7
6
5
4
3
2
1
0
0x64
Yes
7
6
5
4
3
2
1
0
0x64
Yes
7
6
5
4
3
2
1
0
0x64
Yes
R2T
LT
R1T
PHTR2
PHTL
PHTR1
VCCPLO
CYR2
0x00
Yes
CYR2
CYR2
CYL
CYL
CYL
CYR1
CYR1
CYR1
0x00
Yes
PECI
PHTP
CYP
CYP
CYP
RES
RES
RES
0x00
Yes
7
6
5
4
3
2
1
0
0x00
Yes
7
6
5
4
3
2
1
0
0x00
Yes
7
6
5
4
3
2
1
0
0x00
Yes
7
6
5
4
3
2
1
0
0x00
Yes
GPIO1 DIR
Max/Full on
THERM
Lockable?
Rev. 0 | Page 50 of 76
RES
RES
0x00
0x00
0x00
RES
RES
0x00
ADT7490
Table 25. Register 0x10—Configuration Register 6 (Power-On Default = 0x00)1
Bit No.
[0]
Mnemonic
SLOW Remote 1
R/W1
R/W
[1]
SLOW Local
R/W
[2]
SLOW Remote 2
R/W
[3]
[4]
[5]
[6]
Res
Res
Res
VCCP Low
N/A
N/A
N/A
R/W
[7]
ExtraSlow
R/W
1
Description
When this bit is set, fan smoothing times are multiplied ×4 for Remote 1 temperature channel
(as defined in Register 0x62).
When this bit is set, fan smoothing times are multiplied ×4 for local temperature channel
(as defined in Register 0x63).
When this bit is set, fan smoothing times are multiplied ×4 for Remote 2 temperature channel
(as defined in Register 0x63).
Reserved.
Reserved.
Reserved.
VCCP Low = 1. When the power is supplied from 3.3 V STANDBYand the core voltage (VCCP) drops
below its VCCP low limit value (Register 0x46), the following occurs:
Status Bit 1 in Status Register 1 is set.
SMBALERT is generated, if enabled.
PROCHOT monitoring is disabled.
Everything is re-enabled once VCCP increases above the VCCP low limit.
When VCCP increases above the low limit:
PROCHOT monitoring is enabled.
Fans return to their programmed state after a spin-up cycle.
When this bit is set, all fan smoothing times are increased by a further 39.2%
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Table 26. Register 0x11—Configuration Register 7 (Power-On Default = 0x00)
Bit No.
[0]
[1]
Mnemonic
THERMHys
FSPD
R/W1
R/W
R/W
[2]
Vx1
R/W
[3]
FSPDIS
R/W
[4]
TODIS
R/W
[7:5]
RES
N/A
1
Description
THERM hysteresis is enabled by default. Setting this bit to 1 disables THERM hysteresis.
When set to 1, this bit runs all fans at maximum speed as programmed in the maximum PWM duty
cycle registers (0x38 to 0x3A). Power-on default = 0. This bit is not locked at any time.
BIOS should set this bit to a 1 when the ADT7490 is configured to measure current from an Analog
Devices ADOPT® VRM controller and to measure the CPU’s core voltage. This bit allows monitoring
software to display CPU watts usage. (Lockable.)
Logic 1 disables fan spin-up for two TACH pulses. Instead, the PWM outputs go high for the entire fan
spin-up timeout selected.
When this bit is set to 1, the SMBus timeout feature is disabled.
In this state, if at any point during an SMBus transaction involving the ADT7490 activity ceases for
more than 35 ms, the ADT7490 assumes the bus is locked and releases the bus. This allows the
ADT7490 to be used with SMBus controllers that cannot handle SMBus timeouts. (Lockable.)
Reserved. Do not write to these bits.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Table 27. PECI Reading Registers (Power-On Default = 0x80)
Register Address
0x33
0x1A
0x1B
0x1C
R/W
Read-only
Read-only
Read-only
Read-only
Description
PECI0: This register reads the eight bits representative of PECI Client Address 0x30.
PECI1: This register reads the eight bits representative of PECI Client Address 0x31.
PECI2: This register reads the eight bits representative of PECI Client Address 0x32.
PECI3: This register reads the eight bits representative of PECI Client Address 0x33.
Table 28. IMON/VTT Reading Registers (Power-On Default = 0x00)
Register Address
0x1D
R/W
Read-only
0x1E
Read-only
Description
Reflects the voltage measurement at the IMON input on Pin 19 (8 MSBs of reading).
Input range of 0 V to 2.25 V.
Reflects the voltage measurement at the VTT input on Pin 8 (8 MSBs of reading).
Input range of 0 V to 2.25 V.
Rev. 0 | Page 51 of 76
ADT7490
Table 29. Register 0x1F—Extended Resolution 3 (Power-On Default = 0x00)
Bit No.
[3:0]
[5:4]
[7:6]
R/W
Read-only
Read-only
Read-only
Description
Reserved.
Hold the two LSBs of the 10-bit VTT measurement.
Hold the two LSBs of the 10-bit IMON measurement.
Table 30. Voltage Reading Registers (Power-On Default = 0x00)1
Register Address
0x20
0x21
0x22
0x23
0x24
R/W
Read-only
Read-only
Read-only
Read-only
Read-only
Description
Reflects the voltage measurement at the 2.5 VIN input on Pin 22 (8 MSBs of reading).
Reflects the voltage measurement2 at the VCCP input on Pin 23 (8 MSBs of reading).
Reflects the voltage measurement3 at the VCC input on Pin 4 (8 MSBs of reading).
Reflects the voltage measurement at the 5 VIN input on Pin 20 (8 MSBs of reading).
Reflects the voltage measurement at the 12 VIN input on Pin 21 (8 MSBs of reading).
1
If the extended resolution bits of these readings are also being read, the extended resolution registers (Register 0x76, Register 0x77) must be read first. Once the
extended resolution registers have been read, the associated MSB reading registers are frozen until read. Both the extended resolution registers and the MSB registers
are frozen.
2
If VCCP Low (Bit 6 of 0x10) is set, VCCP can control the sleep state of the ADT7490.
3
VCC (Pin 4) is the supply voltage for the ADT7490.
Table 31. Temperature Reading Registers (Power-On Default = 0x80)1, 2
Register Address
0x25
R/W
Read-only
Description
Remote 1 temperature reading3, 4 (8 MSB of reading).
0x26
0x27
Read-only
Read-only
Local temperature reading (8 MSB of reading).
Remote 2 temperature reading3, 4 (8 MSB of reading).
1
If the extended resolution bits of these readings are also being read, the extended resolution registers (Register 0x76, Register 0x77) must be read first. Once the
extended resolution registers have been read, all associated MSB reading registers are frozen until read. Both the extended resolution registers and the MSB registers
are frozen.
2
These temperature readings can be in twos complement or Offset 64 format; this interpretation is determined by Bit 0 of Configuration Register 5 (0x7C).
3
In twos complement mode, a temperature reading of −128°C (0x80) indicates a diode fault (open or short) on that channel.
4
In Offset 64 mode, a temperature reading of −64°C (0x00) indicates a diode fault (open or short) on that channel.
Rev. 0 | Page 52 of 76
ADT7490
Table 32. Fan Tachometer Reading Registers (Power-On Default = 0x00)1
Register Address
0x28
0x29
0x2A
0x2B
0x2C
0x2D
0x2E
0x2F
1
R/W
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Description
TACH1 low byte.
TACH1 high byte.
TACH2 low byte.
TACH2 high byte.
TACH3 low byte.
TACH3 high byte.
TACH4 low byte.
TACH4 high byte.
These registers count the number of 11.11 μs periods (based on an internal 90 kHz clock) that occur between a number of consecutive fan TACH pulses (default = 2).
The number of TACH pulses used to count can be changed using the TACH Pulses per Revolution register (Register 0x7B). This allows the fan speed to be accurately
measured. Because a valid fan tachometer reading requires that two bytes be read, the low byte must be read first. Both the low and high bytes are then frozen until
read. At power-on, these registers contain 0x0000 until the first valid fan TACH measurement is read into these registers. This prevents false interrupts from occurring
while the fans are spinning up.
A count of 0xFFFF indicates that a fan is one of the following: stalled or blocked (object jamming the fan), failed (internal circuitry destroyed), or not populated.
(The ADT7490 expects to see a fan connected to each TACH. If a fan is not connected to that TACH, its TACH minimum high and low bytes should be set to 0xFFFF.) An
alternate function, for example, is TACH4 reconfigured as the THERM pin.
Table 33. Current PWM Duty Cycle Registers (Power-On Default = 0xFF)1
Register Address
0x30
0x31
0x32
1
R/W
R/W
R/W
R/W
Description
PWM1 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
PWM2 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
PWM3 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
These registers reflect the PWM duty cycle driving each fan at any given time. When in automatic fan speed control mode, the ADT7490 reports the PWM duty cycles
back through these registers. The PWM duty cycle values vary according to temperature in automatic fan speed control mode. During fan startup, these registers
report back 0x00. In manual mode, the PWM duty cycle outputs can be set to any duty cycle value by writing to these registers.
Table 34. Register 0x33—PECI0 Reading Register (Power-On Default = 0x80)
Register Address
0x33
R/W
Read-only
Description
PECI0: This register reads the 8 bits representative of PECI Client Address 0x30.
Table 35. PECI Limit Registers
Register Address
0x34
0x35
R/W
R/W
R/W
Description
PECI Low Limit.
PECI High Limit.
Rev. 0 | Page 53 of 76
Power-On Default
0x81
0x00
ADT7490
Table 36. Register 0x36—PECI Configuration Register 1 (Power-On Default = 0x00)
Bit No.
[2:0]
Mnemonic
AVG
R/W1
R/W
Description
PECI Smoothing Interval. These bit set the duration over which smoothing is carried out on the PECI data
read. Note that the PECI smoothing interval is equal to the PECI register update interval.
The smoothing interval is calculated using the following formula:
Smoothing Interval = # reads × (t BIT × 67 × # CPU + t IDLE )
[3]
DOM0
R/W
[4]
REPLACE
R/W
[7:5]
RES
R
1
where:
#reads is the number of readings defined below.
tBIT is the negotiated bit rate.
67 is the number of bits in each PECI reading.
#CPU is the number of CPUs providing PECI data (1 to 4).
tIDLE = 14 μs, the delay between consecutive reads.
Bit Code
Number of PECI readings
000
16
001
2048
010
4096
011
8192
100
16384
101
32768
110
65536
111
Reserved
CPU Domain Count information. Set to 0 indicates that CPU 1 associated with the PECI0 reading has a
single domain (default). Set to 1 indicates that the system CPU 1 contains two domains.
If this bit is set to 0, it indicates that the ADT7490 is operating in standard mode. If this bit is set to 1, the
Remote 1 Temperaute register (Register 0x25) is overwritten by PECI0 information (Register 0x33) and vice
versa. Note that in this mode, all associated user programmable limit and fan control registers are also
swapped and should be programmed in the appropriate PECI or absolute temperature format.
Reserved.
These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 37. Maximum PWM Duty Cycle (Power-On Default = 0xFF)1
R/W2
R/W
R/W
R/W
Register Address
0x38
0x39
0x3A
1
2
Description
Maximum duty cycle for PWM1 output, default = 100% (0xFF).
Maximum duty cycle for PWM2 output, default = 100% (0xFF).
Maximum duty cycle for PWM3 output, default = 100% (0xFF).
These registers set the maximum PWM duty cycle of the PWM output.
These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 38. PECI TMIN Register (Power-On Default = 0xE0,Value = −32)
Register Address
0x3B
1
R/W1
R/W
Description
PECI TMIN. When the PECI measurement exceeds PECI TMIN, the appropriate fans run at PWMMIN and
increase according to the automatic fan speed control slope.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set. Any further attempts to write to this register have no effect.
Rev. 0 | Page 54 of 76
ADT7490
Table 39. Register 0x3C—PECI TRANGE/Enhanced Acoustics Register (Power-On Default = 0xC0)
Bit No.
[2:0]
Mnemonic
ACOU
R/W1
R/W
Description
Assuming that PWMx is associated with the PECI channel, these bits define the maximum rate of
change of the PWMx output for PECI temperature-related changes. Instead of the fan speed jumping
instantaneously to its newly determined speed, it ramps gracefully at the rate determined by these
bits. This feature ultimately enhances the acoustics of the fan.
The smoothing times below are based on a refresh rate of the round robin cycle. The PECI data, for 0%
to 100%, must be multiplied each time by
PECI Refresh Rate
Round Robin Cycle
[3]
ENP
R/W
[7:4]
RANGE
R/W
1
where the PECI refresh rate is defined in Register 0x36 and the round robin cycle is typically 165 ms.
When Bit 7 of Configuration Register 6 (0x10) is 0
Bit Code
Time for 0% to 100%
000 = 1
37.5 sec
001 = 2
18.8 sec
010 = 3
12.5 sec
011 = 4
7.5 sec
100 = 8
4.7 sec
101 = 12
3.1 sec
110 = 24
1.6 sec
111 = 48
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Bit Code
Time for 0% to 100%
000 = 1
52.2 sec
001 = 2
26.1 sec
010 = 3
17.4 sec
011 = 4
10.4 sec
100 = 8
6.5 sec
101 = 12
4.4 sec
110 = 24
2.2 sec
111 = 48
1.1 sec
When this bit is set to 1, smoothing is enabled on the PECI channel allowing enhanced acoustics on
the associated PWM output.
These bits determine the PWM duty cycle vs. the temperature range for automatic fan control.
Bit Code
Temperature
0000
2°C
0001
2.5°C
0010
3.33°C
0011
4°C
0100
5°C
0101
6.67°C
0110
8°C
0111
10°C
1000
13.33°C
1001
16°C
1010
20°C
1011
26.67°C
1100
32°C (default)
1101
40°C
1110
53.33°C
1111
80°C
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Rev. 0 | Page 55 of 76
ADT7490
Table 40. TCONTROL Limit Registers (Power-On Default = 0x00)1
R/W2
Read/write
Register Address
0x3D
Description
PECI TCONTROL limit.
1
If any PECI reading exceeds the TCONTROL limit, all PWM outputs drive their fans at 100% duty cycle. This is a fail-safe mechanism incorporated to cool the system in the
event of a critical overtemperature. It also ensures some level of cooling in the event that software or hardware locks up. If set to 0x80, this feature is disabled. The
PWM output remains at 100% until the temperature drops below TCONTROL limit − hysteresis.
2
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 41. Register 0x3F—Version/Revision Register (Power-On Default = 0x6E)
Bit No.
[1:0]
Mnemonic
REV
R/W
Read
[2]
[3]
PECI
4-Wire
Read
Read
[7:4]
VER
Read
Description
These two bits indicate the ADT7490 silicon revision number. 0x00 indicates Revision 0, 0x01
indicates Revision 1, and so on.
This bit is set to 1 indicating that the ADT7490 supports the PECI interface.
This bit is set to 1 indicating that the ADT7490 may be configured to drive 4-wire fans using high
frequency PWM.
These bits indicate the version number of the device. This is set to 6, indicating that the ADT7490 is
part of the Heceta 6 ASIC family.
Table 42. Register 0x40—Configuration Register 1 (Power-On Default = 0x04)
Bit No.
[0]
Mnemonic
STRT2,3
R/W1
R/W
[1]
LOCK
Write once
[2]
RDY
Read-only
[3]
Fan Boost
R/W
[4]
PECI
Monitor
THERM in
Manual
R/W
[5]
[7:6]
1
2
3
RES
R/W
Read
Description
Logic 1 enables monitoring and PWM control outputs based on the limit settings programmed.
Logic 0 disables monitoring and PWM control is based on the default power-up limit settings.
Note that the limit values programmed are preserved even if a Logic 0 is written to this bit and the
default settings are enabled. This bit does not become locked once Bit 1 (LOCK bit) has been set.
Logic 1 locks all limit values to their current settings. Once this bit is set, all lockable registers
become read-only and cannot be modified until the ADT7490 is powered down and powered up
again. This prevents rogue programs such as viruses from modifying critical system limit settings.
(Lockable.)
This bit is set to 1 by the ADT7490 to indicate that the device is fully powered-up and ready to
begin system monitoring.
When this bit is set to Logic 1, all PWM outputs go to 100% regardless of other fan speed
configurations and automatic fan speed control settings. When this bit is set to 0, the fan speed
control returns to the fan speed setting calculated by the preprogrammed fan speed control
settings. This bit remains writable after the LOCK bit is set.
Set this bit to Logic 1 to enable CPU thermal monitoring via PECI interface. This bit becomes readonly when the LOCK bit is set.
When this bit is set to logic 1, THERM is enabled so that the fans go to 100% duty cycle on a THERM
or TCONTROL assertion overriding any other fan setting, even when the PWMs are configured for
manual mode, or disabled. This bit becomes read-only when the LOCK bit is set.
Reserved.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Bit 0 (STRT) of Configuration Register 1 (0x40) remains writable after the LOCK bit is set.
When monitoring (STRT) is disabled, PWM outputs always go to 100% for thermal protection.
Rev. 0 | Page 56 of 76
ADT7490
Table 43. Register 0x41—Interrupt Status Register 1 (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
+2.5VIN/THERM
R/W
Read-only
[1]
VCCP
Read-only
[2]
VCC
Read-only
[3]
+5VIN
Read-only
[4]
R1T
Read-only
[5]
LT
Read-only
[6]
R2T
Read-only
[7]
OOL
Read-only
Description
+2.5VIN = 1 indicates that the 2.5 VIN high or low limit has been exceeded. This bit is cleared on
a read of the status register only if the error condition has subsided. If Pin 22 is configured as
THERM, this bit is asserted when the timer limit has been exceeded.
VCCP = 1 indicates that the VCCP high or low limit has been exceeded. This bit is cleared on a read of
the status register only if the error condition has subsided.
VCC = 1 indicates that the VCC high or low limit has been exceeded. This bit is cleared on a read of
the status register only if the error condition has subsided.
+5VIN = 1 indicates that the 5 VIN high or low limit has been exceeded. This bit is cleared on a read
of the status register only if the error condition has subsided.
R1T = 1 indicates that the Remote 1 low or high temperature has been exceeded. This bit is cleared
on a read of the status register only if the error condition has subsided.
LT = 1 indicates that the local low or high temperature has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
R2T = 1 indicates that the Remote 2 low or high temperature has been exceeded. This bit is cleared
on a read of the status register only if the error condition has subsided.
OOL = 1 indicates that an out-of-limit event has been latched in Status Register 2 (0x42). This bit is
a logical OR of all status bits in Status Register 2. Software can test this bit in isolation to determine
whether any of the voltage, temperature, or fan speed readings represented by Status Register 2
are out-of-limit, which eliminates the need to read Status Register 2 during every interrupt or
polling cycle.
Table 44. Register 0x42—Interrupt Status Register 2 (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
+12VIN
R/W
Read-only
[1]
OOL
Read-only
[2]
FAN1
Read-only
[3]
FAN2
Read-only
[4]
FAN3
Read-only
[5]
FAN4/THERM
Read-only
Read-only
[6]
[7]
D1 FAULT
D2 FAULT
Read-only
Read-only
Description
+12VIN = 1 indicates that the 12 VIN high or low limit has been exceeded. This bit is cleared on a read
of the status register only if the error condition has subsided.
OOL = 1 indicates that an out-of-limit event has been latched in Status Register 3 (0x43). This bit is
a logical OR of all status bits in Status Register 3. Software can test this bit in isolation to determine
whether any of the voltage, temperature, or fan speed readings represented by Status Register 3
are out-of-limit, which eliminates the need to read Status Register 3 during every interrupt or
polling cycle.
FAN1 = 1 indicates that Fan 1 has dropped below minimum speed or has stalled. This bit is not set
when the PWM1 output is off.
FAN2 = 1 indicates that Fan 2 has dropped below minimum speed or has stalled. This bit is not set
when the PWM2 output is off.
FAN3 = 1 indicates that Fan 3 has dropped below minimum speed or has stalled. This bit is not set
when the PWM3 output is off.
When Pin 14 is programmed as a TACH4 input, FAN4 = 1 indicates that Fan 4 has dropped below
minimum speed or has stalled. This bit is not set when the PWM3 output is off.
If Pin 14 is configured as the THERM timer input for THERM monitoring, this bit is set when the
THERM assertion time exceeds the limit programmed in the THERM timer limit register (Register 0x7A).
D1 FAULT = 1 indicates either an open or short circuit on the Thermal Diode 1 inputs.
D2 FAULT = 1 indicates either an open or short circuit on the Thermal Diode 2 inputs.
Rev. 0 | Page 57 of 76
ADT7490
Table 45. Register 0x43—Interrupt Status Register 3 (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
PECI0
R/W
Read-only
[1]
DATA
Read-only
[2]
COMM
Read-only
[3]
OVT
Read-only
[6:4]
[7]
RES
OOL
Read-only
Read-only
Description
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value from PECI
Client Address 0x30. This bit is cleared on a read of the status register only if the error condition has
subsided.
A Logic 1 indicates that valid PECI data cannot be obtained for the processor and a specified error
code has been recorded.
A Logic 1 indicates that there is a communications error (for example, invalid FCS) on the PECI
interface.
OVT = 1 indicates that one of the THERM overtemperature limits has been exceeded. This bit is cleared
on a read of the status register when the temperature drops below THERM − THYST.
Reserved.
OOL = 1 indicates that an out-of-limit event has been latched in Status Register 4 (0x81). This bit is
a logical OR of all status bits in Status Register 4. Software can test this bit in isolation to determine
whether any of the voltage, temperature, or fan speed readings represented by Status Register 4 are
out-of-limit, which eliminates the need to read Status Register 4 during every interrupt or polling cycle.
Table 46. Voltage Limit Registers1
Register Address
0x44
0x45
0x46
0x47
0x48
0x49
0x4A
0x4B
0x4C
0x4D
1
2
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description2
+2.5VIN low limit.
+2.5VIN high limit.
VCCP low limit.
VCCP high limit.
VCC low limit.
VCC high limit.
+5VIN low limit.
+5VIN high limit.
+12VIN low limit.
+12VIN high limit.
Power-On Default
0x00
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xFF
Setting the Configuration Register 1 (0x40) LOCK bit has no effect on these registers.
High limits: An interrupt is generated when a value exceeds its high limit (> comparison). Low limits: An interrupt is generated when a value is equal to or below its
low limit (≤ comparison).
Table 47. Temperature Limit Registers1
Register Address
0x4E
R/W
R/W
Description2
Remote 1 temperature low limit.
Power-On Default
0x81
0x4F
0x50
0x51
0x52
0x53
R/W
R/W
R/W
R/W
R/W
Remote 1 temperature high limit.
Local temperature low limit.
Local temperature high limit.
Remote 2 temperature low limit.
Remote 2 temperature high limit.
0x7F
0x81
0x7F
0x81
0x7F
1
Exceeding any of these temperature limits by 1°C causes the appropriate status bit to be set in the interrupt status register. Setting the Configuration Register 1 LOCK
(0x40) bit has no effect on these registers.
2
High limits: An interrupt is generated when a value exceeds its high limit (> comparison). Low limits: An interrupt is generated when a value is equal to or below its
low limit (≤ comparison).
Rev. 0 | Page 58 of 76
ADT7490
Table 48. Fan Tachometer Limit Registers1
Register Address
0x54
0x55
0x56
0x57
0x58
0x59
0x5A
0x5B
1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
TACH1 minimum low byte.
TACH1 minimum high byte/single-channel ADC channel select.
TACH2 minimum low byte.
TACH2 minimum high byte.
TACH3 minimum low byte.
TACH3 minimum high byte.
TACH4 minimum low byte.
TACH4 minimum high byte.
Power-On Default
0xFF
0xFF
0xFF
0xFF
0xFF
0xFF
0xFF
0xFF
Exceeding any of the TACH limit registers by 1 indicates that the fan is running too slowly or has stalled. The appropriate status bit is set in Interrupt Status Register 2
(0x42) to indicate the fan failure. Setting the Configuration Register 1 (0x40) LOCK bit has no effect on these registers.
Table 49. Register 0x55—TACH1 Minimum High Byte (Power-On Default = 0xFF)
Bits
[3:0]
Mnemonic
Reserved
R/W
Read-only
[7:4]
SCADC
R/W
Description
When Bit 6 of Configuration 2 Register (0x73) is set (single-channel ADC mode), these bits are reserved.
Otherwise, these bits represent Bits [3:0] of the TACH1 minimum high byte.
When Bit 6 of Configuration 2 Register (0x73) is set (single-channel ADC mode), these bits are used to
select the only channel from which the ADC will take measurements. Otherwise, these bits represent
Bits [7:4] of the TACH1 minimum high byte.
Bit Code
Single-Channel Select
0000
+2.5VIN
0001
VCCP
0010
VCC
0011
+5VIN
0100
+12VIN
0101
Remote 1 temperature
0110
Local temperature
0111
Remote 2 temperature
1000
VTT
1001
IMON
Rev. 0 | Page 59 of 76
ADT7490
Table 50. PWM Configuration Registers
R/W1
R/W
R/W
R/W
Register Address
0x5C
0x5D
0x5E
1
Description
PWM1 configuration.
PWM2 configuration.
PWM3 configuration.
Power-On Default
0x62
0x62
0x62
These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 51. Register 0x5C, Register 0x5D, and Register 0x5E—PWM1, PWM2, and PWM3 Configuration Registers
(Power-On Default = 0x62)
Bit No.
[2:0]
Mnemonic
SPIN
R/W1
R/W
[3]
ALT
R/W
[4]
INV
R/W
[7:5]
BHVR2
R/W
1
2
Description
These bits control the start-up timeout for PWMx. The PWM output stays high until
two valid TACH rising edges are seen from the fan. If there is not a valid TACH signal
during the fan TACH measurement directly after the fan start-up timeout period, the
TACH measurement reads 0xFFFF and Status Register 2 reflects the fan fault. If the
TACH minimum high and low bytes contain 0xFFFF or 0x0000, then the Status
Register 2 bit is not set, even if the fan has not started.
Bit Code
Start-up Timeout
000
No start-up timeout
001
100 ms
010
250 ms (default)
011
400 ms
100
667 ms
101
1 sec
110
2 sec
111
4 sec
Use alternative behavior setting options in Bits[7:5] below for PWMx by setting this
bit to 1. Default =0.
This bit inverts the PWM output. The default is 0, which corresponds to a logic high
output for 100% duty cycle. Setting this bit to 1 inverts the PWM output, so 100%
duty cycle corresponds to a logic low output.
These bits assign each fan to a particular temperature sensor for localized cooling.
Setting Bit 3 to Logic 1 in this register chooses whether the default of alternative
behavior option is selected.
Default Behavior Bits
Alternative Behavior Bits2
000 = Remote 1 temperature controls
000 = PECI0 reading controls PWMx
PWMx (automatic fan control mode).
(automatic fan control mode).
001 = Local temperature controls PWMx
001 = PECI1 reading controls PWMx
(automatic fan control mode).
(automatic fan control mode).
010 = Remote 2 temperature controls
010 = PECI2 reading controls PWMx
PWMx (automatic fan control mode).
(automatic fan control mode).
011 = PWMx runs full speed (default).
011 = PECI3 reading controls PWMx
(automatic fan control mode).
100 = PWMx disabled.
100 = Reserved. If selected, fans run at
100% duty cycle.
101 = Fastest speed calculated by local
101 = Fastest of all 4 PECI channels.
and Remote 2 temperature controls
Fastest speed calculated by all 4 PECI
PWMx.
readings.
110 = Fastest speed calculated by all
110 = Reserved. If selected, fans run at
three temperature channel controls
100% duty cycle.
PWMx.
111 = Manual mode. PWM duty cycle
111 = Fastest speed calculated by all of
registers (Register 0x30 to Register 0x32) the thermal zones (Local, Remote 1,
become writable.
Remote 2 and PECI temperatures).
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
When REPLACE mode is selected, (Register 0x36, Bit 4 set to 1) PWM1 is automatically configured for the alternative behavior setting. Register 0x36 Bits [7:5] should be set to
000 only.
Rev. 0 | Page 60 of 76
ADT7490
Table 52. Temperature TRANGE/PWM Frequency Registers
R/W1
R/W
R/W
R/W
Register Address
0x5F
0x60
0x61
1
Description
Remote 1 TRANGE/PWM1 frequency.
Local temperature TRANGE/PWM2 frequency.
Remote 2 TRANGE/PWM3 frequency.
Power-On Default
0xC4
0xC4
0xC4
These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set. Any further attempts to write to these registers have no effect.
Table 53. Register 0x5F, Register 0x60, and Register 0x61—Remote 1 TRANGE/PWM1 Frequency, Local Temperature TRANGE/PWM2
Frequency, and Remote 2 TRANGE/PWM3 Frequency (Power-On Default = 0xC4)
Bit No.
[2:0]
Mnemonic
FREQ
R/W1
R/W
[3]
HF/LF
R/W
[7:4]
RANGE
R/W
1
Description
These bits control the PWMx frequency (only apply when PWM channel is in low frequency mode).
Bit Code
Frequency
000
11.0 Hz
001
14.7 Hz
010
22.1 Hz
011
29.4 Hz
100
35.3 Hz (default)
101
44.1 Hz
110
58.8 Hz
111
88.2 Hz
HF/LF = 1, high frequency PWM mode is enabled for PWMx.
HF/LF = 0, low frequency PWM mode is enabled for PWMx.
These bits determine the PWM duty cycle vs. the temperature range for automatic fan control.
Bit Code
Temperature
0000
2°C
0001
2.5°C
0010
3.33°C
0011
4°C
0100
5°C
0101
6.67°C
0110
8°C
0111
10°C
1000
13.33°C
1001
16°C
1010
20°C
1011
26.67°C
1100
32°C (default)
1101
40°C
1110
53.33°C
1111
80°C
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set. Any further attempts to write to this register have no effect.
Rev. 0 | Page 61 of 76
ADT7490
Table 54. Register 0x62—Enhanced Acoustics Register 1 (Power-On Default = 0x00)
Bit No.
[2:0]
Mnemonic
ACOU2
R/W1
R/W
[3]
[4]
EN1
SYNC
R/W
R/W
[5]
MIN1
R/W
[6]
MIN2
R/W
[7]
MIN3
R/W
1
2
Description
Assuming that PWMx is associated with the Remote 1 temperature channel, these bits define the
maximum rate of change of the PWMx output for Remote 1 temperature-related changes. Instead of
the fan speed jumping instantaneously to its newly determined speed, it ramps gracefully at the rate
determined by these bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Bit Code
Time for 0% to 100%
000 = 1
37.5 sec
001 = 2
18.8 sec
010 = 3
12.5 sec
011 = 4
7.5 sec
100 = 8
4.7 sec
101 = 12
3.1 sec
110 = 24
1.6 sec
111 = 48
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Bit Code
Time for 0% to 100%
000 = 1
52.2 sec
001 = 2
26.1 sec
010 = 3
17.4 sec
011 = 4
10.4 sec
100 = 8
6.5 sec
101 = 12
4.4 sec
110 = 24
2.2 sec
111 = 48
1.1 sec
When this bit is 1, smoothing is enabled on Remote 1 temperature channel.
SYNC = 1 synchronizes fan speed measurements on TACH2, TACH3, and TACH4 to PWM3. This allows
up to three fans to be driven from PWM3 output and their speeds to be measured.
SYNC = 0 synchronizes only TACH3 and TACH4 to PWM3 output.
When the ADT7490 is in automatic fan control mode, this bit defines whether PWM1 is off
(0% duty cycle) or at PWM1 minimum duty cycle when the controlling temperature is below its
TMIN − hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM1 minimum duty cycle below TMIN – hysteresis.
When the ADT7490 is in automatic fan speed control mode, this bit defines whether PWM2 is off
(0% duty cycle) or at PWM2 minimum duty cycle when the controlling temperature is below its
TMIN − hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM2 minimum duty cycle below TMIN – hysteresis.
When the ADT7490 is in automatic fan speed control mode, this bit defines whether PWM3 is off
(0% duty cycle) or at PWM3 minimum duty cycle when the controlling temperature is below its
TMIN – hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM3 minimum duty cycle below TMIN – hysteresis.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Setting the relevant bit of Configuration Register 6 (0x10, Bits [2:0]) further decreases these ramp rates by a factor of 4.
Rev. 0 | Page 62 of 76
ADT7490
Table 55. Register 0x63—Enhanced Acoustics Register 2 (Power-On Default = 0x00)
Bit No.
[2:0]
Mnemonic
ACOU3
R/W1
R/W
[3]
[6:4]
EN3
ACOU2
R/W
R/W
[7]
EN2
R/W
1
Description
Assuming that PWMx is associated with the local temperature channel, these bits define the
maximum rate of change of the PWMx output for local temperature-related changes. Instead of the
fan speed jumping instantaneously to its newly determined speed, it ramps gracefully at the rate
determined by these bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Bit Code
Time for 0% to 100%
000 = 1
37.5 sec
001 = 2
18.8 sec
010 = 3
12.5 sec
011 = 4
7.5 sec
100 = 8
4.7 sec
101 = 12
3.1 sec
110 = 24
1.6 sec
111 = 48
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Bit Code
Time for 0% to 100%
000 = 1
52.2 sec
001 = 2
26.1 sec
010 = 3
17.4 sec
011 = 4
10.4 sec
100 = 8
6.5 sec
101 = 12
4.4 sec
110 = 24
2.2 sec
111 = 48
1.1 sec
When this bit is 1, smoothing is enabled on the local temperature channel.
Assuming that PWMx is associated with the Remote 2 temperature channel, these bits define the
maximum rate of change of the PWMx output for Remote 2 Temperature related changes. Instead of
the fan speed jumping instantaneously to its newly determined speed, it ramps gracefully at the rate
determined by these bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
Time for 0% to 100%
000 = 1
37.5 sec
001 = 2
18.8 sec
010 = 3
12.5 sec
011 = 4
7.5 sec
100 = 8
4.7 sec
101 = 12
3.1 sec
110 = 24
1.6 sec
111 = 48
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
Time for 0% to 100%
000 = 1
52.2 sec
001 = 2
26.1 sec
010 = 3
17.4 sec
011 = 4
10.4 sec
100 = 8
6.5 sec
101 = 12
4.4 sec
110 = 24
2.2 sec
111 = 48
1.1 sec
When this bit is 1, smoothing is enabled on the Remote 2 temperature channel.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Rev. 0 | Page 63 of 76
ADT7490
Table 56. PWM Minimum Duty Cycle Registers
Register Address
0x64
0x65
0x66
1
R/W1
R/W
R/W
R/W
Description
PWM1 minimum duty cycle.
PWM2 minimum duty cycle.
PWM3 minimum duty cycle.
Power-On Default
0x80 (50% duty cycle)
0x80 (50% duty cycle)
0x80 (50% duty cycle)
These registers become read-only when the ADT7490 is in automatic fan control mode.
Table 57. Register 0x64, Register 0x65, and Register 0x66—PWM1, PWM2, and PWM3 Min Duty Cycles (Power-On Default = 0x80)
Bit No.
[7:0]
1
Mnemonic
PWM duty cycle
R/W1
R/W
Description
These bits define the PWMMIN duty cycle for PWMx.
0x00 = 0% duty cycle (fan off ).
0x40 = 25% duty cycle.
0x80 = 50% duty cycle.
0xFF = 100% duty cycle (fan full speed).
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect..
Table 58. TMIN Registers1
Register Address
0x67
0x68
0x69
1
2
R/W2
R/W
R/W
R/W
Description
Remote 1 Temperature TMIN.
Local Temperature TMIN.
Remote 2 Temperature TMIN.
Power-On Default
0x5A (90°C)
0x5A (90°C)
0x5A (90°C)
These are the TMIN registers for each temperature channel. When the temperature measured exceeds TMIN, the appropriate fan runs at minimum speed and increases
with temperature according to TRANGE.
These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set. Any further attempts to write to these registers have no effect.
Table 59. THERM Limit Registers1
Register Address
0x6A
0x6B
0x6C
R/W2
R/W
R/W
R/W
Description
Remote 1 THERM temperature limit.
Local THERM temperature limit.
Remote 2 THERM temperature limit.
Power-On Default
0x64 (100°C)
0x64 (100°C)
0x64 (100°C)
If any temperature measured exceeds its THERM limit, all PWM outputs drive their fans at 100% duty cycle. This is a fail-safe mechanism incorporated to cool the
system in the event of a critical over temperature. It also ensures some level of cooling in the event that software or hardware locks up. If set to 0x80, this feature is
disabled. The PWM output remains at 100% until the temperature drops below THERM limit − hysteresis. If the THERM pin is programmed as an output, exceeding
these limits by 0.25°C can cause the THERM pin to assert low as an output.
2
These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to these registers have no effect.
1
Rev. 0 | Page 64 of 76
ADT7490
Table 60. Temperature/TMIN Hysteresis Registers
Register Address
0x6D
0x6E
1
R/W1
R/W
R/W
Description
Remote 1 and Local Temperature/TMIN hysteresis.
PECI and Remote 2 Temperature/TMIN hysteresis.
Power-On Default
0x44
0x44
These registers become read-only when the Configuration Register 1(0x40) LOCK bit is set to 1. Any further attempts to write to these registers have no effect.
Table 61. Register 0x6D—Remote 1 and Local Temp/TMIN Hysteresis (Power-On Default = 0x44)
Bit No.1
[3:0]
Mnemonic
HYSL
R/W2
R/W
[7:4]
HYSR1
R/W
Description
Local Temperature Hysteresis. 0°C to 15°C of hysteresis can be applied to the Local temperature AFC
control loops.
Remote 1 Temperature Hysteresis. 0°C to 15°C of hysteresis can be applied to the Remote 1 Temperature
AFC control loops.
1
Each 4-bit value controls the amount of temperature hysteresis applied to a particular temperature channel. Once the temperature for that channel falls below its
TMIN value, the fan remains running at PWMMIN duty cycle until the temperature = TMIN − hysteresis. Up to 15°C of hysteresis can be assigned to any temperature
channel. The hysteresis value chosen also applies to that temperature channel if its THERM limit is exceeded. The PWM output being controlled goes to 100%, if the
THERM limit is exceeded and remains at 100% until the temperature drops below THERM − hysteresis. For acoustic reasons, it is recommended that the hysteresis
value not be programmed less than 4°C. Setting the hysteresis value lower than 4°C causes the fan to switch on and off regularly when the temperature is close to TMIN.
2
These registers become read-only when the Configuration Register 1 LOCK bit is set to 1. Any further attempts to write to these registers have no effect.
Table 62. Register 0x6E—Remote 2 and PECI Temp/TMIN Hysteresis (Power-On Default = 0x44)
Bit No.1
[3:0]
[7:4]
Mnemonic
HYSP
HYSR2
R/W2
R/W
R/W
Description
PECI Temperature Hysteresis. 0°C to 15°C of hysteresis can be applied to the PECI AFC control loops.
Remote 2 Temperature Hysteresis. 0°C to 15°C of hysteresis can be applied to the Local Temperature
AFC control loops.
1
Each 4-bit value controls the amount of temperature hysteresis applied to a particular temperature channel. Once the temperature for that channel falls below its
TMIN value, the fan remains running at PWMMIN duty cycle until the temperature = TMIN − hysteresis. Up to 15°C of hysteresis can be assigned to any temperature
channel. The hysteresis value chosen also applies to that temperature channel, if its THERM limit is exceeded. The PWM output being controlled goes to 100%, if the
THERM limit is exceeded and remains at 100% until the temperature drops below THERM − hysteresis. For acoustic reasons, it is recommended that the hysteresis
value not be programmed less than 4°C. Setting the hysteresis value lower than 4°C causes the fan to switch on and off regularly when the temperature is close to TMIN.
2
These registers become read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to these registers have no effect.
Table 63. Register 0x6F—XNOR Tree Test Enable (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
XEN
R/W1
R/W
[7:1]
RES
R/W
1
Description
If the XEN bit is set to 1, the device enters the XNOR tree test mode. Clearing the bit removes
the device from the XNOR tree test mode.
Unused/reserved. Do not write to these bits.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 64. Register 0x70—Remote 1 Temperature Offset (Power-On Default = 0x00)
Bit No.
[7:0]
1
R/W1
R/W
Description
Allows a temperature offset to be automatically applied to the Remote 1 temperature channel measurement.
Bit 1 of Configuration Register 5 (0x7C) determines the range and resolution of this register.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Rev. 0 | Page 65 of 76
ADT7490
Table 65. Register 0x71—Local Temperature Offset (Power-On Default = 0x00)
Bit No.
[7:0]
1
R/W1
R/W
Description
Allows a temperature offset to be automatically applied to the local temperature measurement. Bit 1 of
Configuration Register 5 (0x7C) determines the range and resolution of this register.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 66. Register 0x72—Remote 2 Temperature Offset (Power-On Default = 0x00)
Bit No.
[7:0]
1
R/W1
R/W
Description
Allows a temperature offset to be automatically applied to the Remote 2 temperature channel measurement.
Bit 1 of Configuration Register 5 (0x7C) determines the range and resolution of this register.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 67. Register 0x73—Configuration Register 2 (Power-On Default = 0x00)
Bit No.
0
Mnemonic
FanPresDT
R/W1
R/W
1
2
3
4
Fan1Detect
Fan2Detect
Fan3Detect
AVG
Read
Read
Read
R/W
5
ATTN
R/W
6
CONV
R/W
7
Shutdown
R/W
1
Description
When FanPresDT = 1, the state of Bits [3:1] of this register reflects the presence of a 4-wire fan on
the appropriate TACH channel.
Fan1Detect = 1 indicates that a 4-wire fan is connected to the PWM1 input.
Fan2Detect = 1 indicates that a 4-wire fan is connected to the PWM2 input.
Fan3Detect = 1 indicates that a 4-wire fan is connected to the PWM3 input.
AVG = 1 indicates that averaging on the temperature and voltage measurements is turned off. This
allows measurements on each channel to be made much faster (x16).
ATTN = 1 indicates that the ADT7490 removes the attenuators from the +2.5VIN, VCCP, +5VIN, and
+12VIN inputs. These inputs can be used for other functions such as connecting up external
sensors. It is also possible to remove attenuators from individual channels using Bits [7:4] of
Configuration Register 4 (0x7D).
CONV = 1 indicates that the ADT7490 is put into a single-channel ADC conversion mode. In
this mode, the ADT7490 can be made to read continuously from one input only, for example,
Remote 1 temperature. The appropriate ADC channel is selected by writing to Bits [7:4] of TACH1
minimum high byte register (0x55).
When CONV = 1, Bits [7:4], Register 0x55
Bit Code
ADC Channel Selected
0000
+2.5VIN
0001
VCCP
0010
VCC
0011
+5VIN
0100
+12VIN
0101
Remote 1 temperature
0110
Local temperature
0111
Remote 2 temperature
1000
VTT
1001
IMON
When the shutdown bit is set to 1, the ADT7490 goes into shutdown mode.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Rev. 0 | Page 66 of 76
ADT7490
Table 68. Register 0x74—Interrupt Mask Register 1 (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
+2.5VIN/THERM
R/W
R/W
[1]
[2]
[3]
[4]
[5]
[6]
[7]
VCCP
VCC
+5VIN
R1T
LT
R2T
OOL
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
+2.5VIN/THERM = 1 masks SMBALERT for out-of-limit conditions on the +2.5VIN/THERM timer
channel.
VCCP = 1 masks SMBALERT for out-of-limit conditions on the VCCP channel.
VCC = 1 masks SMBALERT for out-of-limit conditions on the VCC channel.
+5VIN = 1 masks SMBALERT for out-of-limit conditions on the +5VIN channel.
R1T = 1 masks SMBALERT for out-of-limit conditions on the Remote 1 temperature channel.
LT = 1 masks SMBALERT for out-of-limit conditions on the Local temperature channel.
R2T = 1 masks SMBALERT for out-of-limit conditions on the Remote 2 temperature channel.
OOL = 1 masks SMBALERT assertions when the OOL status bit is set.
Note that the OOL mask bit is independent of the individual mask bits associated with Interrupt
Status 2 register. Therefore, if the intention is to mask SMBALERT assertions for any of the Interrupt
Status 2 register bits, OOL must also be masked.
Table 69. Register 0x75—Interrupt Mask Register 2 (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
+12VIN
R/W
R/W
[1]
OOL
R/W
[2]
[3]
[4]
[5]
FAN1
FAN2
FAN3
F4P
R/W
R/W
R/W
R/W
[6]
[7]
D1
D2
R/W
R/W
Description
When Pin 21 is configured as a +12VIN input, +12VIN = 1 masks SMBALERT for out-of-limit conditions
on the +12VIN channel.
OOL = 1 masks SMBALERT assertions when the OOL status bit is set.
Note that the OOL mask bit is independent of the individual mask bits in Interrupt Mask 3 register
(0x82). Therefore, if the intention is to mask SMBALERT assertions for any of the Status Register 4 bits,
OOL must also be masked.
FAN1 = 1 masks SMBALERT for a Fan 1 fault.
FAN2 = 1 masks SMBALERT for a Fan 2 fault.
FAN3 = 1 masks SMBALERT for a Fan 3 fault.
If Pin 14 is configured as TACH4, F4P = 1 masks SMBALERT for a Fan 4 fault.
If Pin 14 is configured as THERM, F4P = 1 masks SMBALERT for an exceeded THERM timer limit.
D1 = 1 masks SMBALERT for a diode open or short on a Remote 1 channel.
D2 = 1 masks SMBALERT for a diode open or short on a Remote 2 channel.
Table 70. Register 0x76—Extended Resolution Register 1 (Power-On Default = 0x00)1
Bit No.
[1:0]
[3:2]
[5:4]
[7:6]
1
Mnemonic
+2.5VIN
VCCP
VCC
+5VIN
R/W
Read-only
Read-only
Read-only
Read-only
Description
+2.5VIN LSBs. Holds the 2 LSBs of the 10-bit +2.5VIN measurement.
VCCP LSBs. Holds the 2 LSBs of the 10-bit VCCP measurement.
VCC LSBs. Holds the 2 LSBs of the 10-bit VCC measurement.
+5VIN LSBs. Holds the 2 LSBs of the 10-bit +5VIN measurement.
If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
Table 71. Register 0x77—Extended Resolution Register 2 (Power-On Default = 0x00)1
Bit
[1:0]
[3:2]
[5:4]
[7:6]
1
Name
+12VIN
TDM1
LTMP
TDM2
R/W
Read-only
Read-only
Read-only
Read-only
Description
+12VIN LSBs. Holds the 2 LSBs of the 10-bit +12VIN measurement.
Remote 1 Temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 1 temperature measurement.
Local Temperature LSBs. Holds the 2 LSBs of the 10-bit local temperature measurement.
Remote 2 Temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 2 temperature measurement.
If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
Rev. 0 | Page 67 of 76
ADT7490
Table 72. Register 0x78—Configuration Register 3 (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
ALERT
Enable
R/W1
R/W
[1]
THERM/
+2.5VIN
R/W
[2]
BOOST
R/W
[3]
FAST
R/W
[4]
DC1
R/W
[5]
DC2
R/W
[6]
DC3
R/W
[7]
DC4
R/W
1
Description
ALERT = 1, Pin 10 (PWM2/SMBALERT) is configured as an SMBALERT interrupt output to indicate
out-of-limit error conditions.
ALERT = 0, Pin 10 (PWM2/SMBALERT) is configured as the PWM2 output.
THERM = 1 enables THERM functionality on Pin 22 and Pin 14, if Pin 14 is configured as THERM,
determined by Bit 0 and Bit 1 (Pin 14 Func) of Configuration Register 4 (0x7D). When THERM is
asserted, if the fans are running and the boost bit is set, then the fans run at full speed. Alternatively, THERM can be programmed so that a timer is triggered to time how long THERM has been
asserted.
THERM = 0 enables +2.5VIN measurement on Pin 22 and disables THERM. If Bits [5:7] of Configuration
Register 5 (0x7C) are set, THERM is bidirectional. If they are 0, THERM is a timer input only.
Pin 14 Func (0x7D)
THERM/+2.5VIN (0x78)
Pin 22
Pin 14
00
01
10
11
00
01
10
11
0
0
0
0
1
1
1
1
+2.5VIN
+2.5VIN
+2.5VIN
+2.5VIN
THERM
+2.5VIN
THERM
THERM
TACH4
TACH4
SMBALERT
N/A
TACH4
THERM
SMBALERT
N/A
When THERM is an input and BOOST = 1, assertion of THERM causes all fans to run at the
maximum programmed duty cycle for fail-safe cooling.
FAST = 1 enables fast TACH measurements on all channels. This increases the TACH measurement
rate from once per second to once every 250 ms (4×).
DC1 = 1 enables TACH measurements to be continuously made on TACH1. Fans must be driven by
dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors.
DC2 = 1 enables TACH measurements to be continuously made on TACH2. Fans must be driven by
dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors.
DC3 = 1 enables TACH measurements to be continuously made on TACH3. Fans must be driven by
dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors.
DC4 = 1 enables TACH measurements to be continuously made on TACH4. Fans must be driven by
dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors.
Bits [3:0] of this register become read-only when the Configuration Register 1 LOCK (0x40) bit is set to 1. Any further attempts to write to Bits [3:0] have no effect.
Table 73. Register 0x79—THERM Timer Status Register (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
ASRT/
TMR0
R/W
R/W
[7:1]
TMR
R/W
Description
This bit is set high on the assertion of the THERM input and is cleared on read. If the THERM assertion
time exceeds 45.52 ms, this bit is set and becomes the LSB of the 8-bit TMR reading. This allows THERM
assertion times from 45.52 ms to 5.82 sec to be reported back with a resolution of 22.76 ms.
Times how long THERM input is asserted. These seven bits read zero until the THERM assertion time
exceeds 45.52 ms.
Table 74. Register 0x7A—THERM Timer Limit Register (Power-On Default = 0x00)
Bit No.
[7:0]
Mnemonic
LIMT
R/W
R/W
Description
Sets maximum THERM assertion length allowed before an interrupt is generated. This is an 8-bit limit
with a resolution of 22.76 ms allowing THERM assertion limits of 45.52 ms to 5.82 s to be programmed.
If the THERM assertion time exceeds this limit, Bit 5 (FAN4/THERM) of Interrupt Status 2 register (0x42)
is set. If the limit value is 0x00, an interrupt is generated immediately on the assertion of the THERM
input. If THERM is configured as an output, the THERM timer limit should be set to 0xFF to avoid
unwanted alerts from being generated.
Rev. 0 | Page 68 of 76
ADT7490
Table 75. Register 0x7B—TACH Pulses per Revolution Register (Power-On Default = 0x55)
Bit No.
[1:0]
Mnemonic
FAN1
R/W
R/W
[3:2]
FAN2
R/W
[5:4]
FAN3
R/W
[7:6]
FAN4
R/W
Description
Sets number of pulses to be counted when measuring Fan 1 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Bit Code
Pulses Counted
00
1
01
2 (default)
10
3
11
4
Sets number of pulses to be counted when measuring Fan 2 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Bit Code
Pulses Counted
00
1
01
2 (default)
10
3
11
4
Sets number of pulses to be counted when measuring Fan 3 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Bit Code
Pulses Counted
00
1
01
2 (default)
10
3
11
4
Sets number of pulses to be counted when measuring Fan 4 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Bit Code
Pulses Counted
00
1
01
2 (default)
10
3
11
4
Table 76. Register 0x7C—Configuration Register 5 (Power-On Default = 0x01)
Bit No.
[0]
Mnemonic
TWOS COMPL
R/W1
R/W
[1]
Temp Offset
R/W
[2]
[3]
[4]
RES
RES
PECI R1
THERM
Output Only
R/W
R/W
R/W
Description
TWOS COMPL = 1 sets the temperature range to the twos complement temperature range.
TWOS COMPL = 0 changes the temperature range to the Offset 64 temperature range. When this
bit is changed, the ADT7490 interprets all relevant temperature register values as defined by this bit.
Temp Offset = 0 sets offset range to −63°C to +64°C with 0.5°C resolution.
Temp Offset = 1 sets offset range to −63°C to +127°C with 1°C resolution.
These settings apply to Register 0x70, Register 0x71, and Register 0x72 (Remote 1, Internal, and
Remote 2 Temperature offset registers. Note that PECI offset is always 1°C resolution).
Reserved.
Reserved.
PECI R1 = 1 enables THERM assertions when the PECI temperature read is higher than the PECI
TCONTROL limit and the THERM pin is bidirectional. If THERM is configured as an output, the THERM
timer limit register (0x7A) should be set to 0xFF to avoid unwanted alerts from being generated.
PECI R1 = 0 indicates that the THERM pin is configured as a timer input only. Can also be disabled
by writing one of the following values to the PECI TCONTROL limit register (0x3D):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
Rev. 0 | Page 69 of 76
ADT7490
Bit No.
[5]
Mnemonic
R1 THERM
Output Only
R/W1
R/W
[6]
Local THERM
Output Only
R/W
[7]
R2 THERM
Output Only
R/W
1
Description
R1 = 1 enables THERM assertions when the Remote 1 temperature read is higher than the
Remote 1 THERM limit and the THERM pin is bidirectional. If THERM is configured as an output, the
THERM timer limit (Register 0x7A) should be set to 0xFF to avoid unwanted alerts from being
generated.
R1 = 0 indicates that the THERM pin is configured as a timer input only. Can also be disabled by
writing one of the following values to the Remote 1 THERM Temp Limit register (0x6A):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
R1 = 1 enables THERM assertions when the Local temperature read is higher than the Local
THERM limit and the THERM pin is bidirectional. If THERM is configured as an output, the THERM
timer limit (Register 0x7A) should be set to 0xFF to avoid unwanted alerts from being generated.
R1 = 0 indicates that the THERM pin is configured as a timer input only. Can also be disabled by
writing one of the below values to the Local THERM Limit register (0x6B):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
R1 = 1 enables THERM assertions when the Remote 2 temperature read is higher than the
Remote 2 THERM limit and the THERMpin is bidirectional. If THERM is configured as an output
the THERM timer limit (Register 0x7A) should be set to 0xFF to avoid unwanted alerts from being
generated.
R1 = 0 indicates that the THERM pin is configured as a timer input only. C an also be disabled by
writing one of the below values to the Remote 2 THERM Temp Limit register (0x6C):
Writing −64°C in Offset 64 mode.
Writing −128°C in twos complement mode.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 77. Register 0x7D—Configuration Register 4 (Power-On Default = 0x00)
Bit No.
[1:0]
Mnemonic
Pin 14 Func
R/W1
R/W
[2]
THERM
Disable
R/W
[3]
Max/Full on
THERM
R/W
[4]
R/W
[5]
BpAtt
+2.5VIN
BpAtt VCCP
[6]
BpAtt +5VIN
R/W
[7]
BpAtt
+12VIN
R/W
1
R/W
Description
These bits set the functionality of Pin 14.
00 = TACH4 (default)
01 = THERM
10 = SMBALERT
11 = Reserved
THERM Disable = 0 enables THERM overtemperature output assuming THERM is correctly
configured (0x78, 0x7C, and 0x7D).
THERM Disable = 1 disables THERM overtemperature output on all channels.
THERM can also be disabled on any channel by:
Writing −64°C to the appropriate THERM temperature limit in Offset 64 mode.
Writing −128°C to the appropriate THERM temperature limit in twos complement mode.
Max/Full on THERM = 0 indicates that fans go to 100% when THERM temperature limit is exceeded.
Max/Full on THERM = 1 indicates that fans go to maximum speed (0x38, 0x39, 0x3A) when THERM
temperature limit is exceeded.
Bypass +2.5VIN attenuator. When set, the measurement scale for this channel changes from 0 V
(0x00) to 2.25 V (0xFF).
Bypass VCCP attenuator. When set, the measurement scale for this channel changes from 0 V (0x00)
to 2.25 V (0xFF).
Bypass +5VIN attenuator. When set, the measurement scale for this channel changes from 0 V (0x00)
to 2.25 V (0xFF).
Bypass +12VIN attenuator. When set, the measurement scale for this channel changes from 0 V
(0x00) to 2.25 V (0xFF).
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Rev. 0 | Page 70 of 76
ADT7490
Table 78. Register 0x7E—Manufacturer’s Test Register 1 (Power-On Default = 0x00)
Bit No.
[7:0]
Mnemonic
Reserved
R/W
Read-only
Description
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and
should not be written to under normal operation.
Table 79. Register 0x7F—Manufacturer’s Test Register 2 (Power-On Default = 0x00)
Bit No.
[7:0]
Mnemonic
Reserved
R/W
Read-only
Description
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and
should not be written to under normal operation.
Table 80. Register 0x80—GPIO Configuration Register (Power-On Default = 0x00)
Bit No.
[1:0]
[2]
Mnemonic
RES
GPIO2
R/W
Reserved
R/W
[3]
GPIO1
R/W
[4]
[5]
[6]
[7]
GPIO2 POL
GPIO1 POL
GPIO2 DIR
GPIO1 DIR
R/W
R/W
R/W
R/W
Description
Reserved.
If GPIO2 is set to input, this register reflects the state of the pin. If GPIO2 is configured as an output,
writing to this register asserts the output high or low depending on the polarity.
If GPIO1 is set to input, this register reflects the state of the pin. If GPIO1 is configured as an output,
writing to this register asserts the output high or low depending on the polarity.
GPIO2 polarity bit. Set to 0 for active low. Set to 1 for active high.
GPIO1 polarity bit. Set to 0 for active low. Set to 1 for active high.
GPIO2 direction bit. Set to 1 for GPIO1 to act as an input, set to 0 for GPIO2 to act as an output.
GPIO1 direction bit. Set to 1 for GPIO1 to act as an input, set to 0 for GPIO1 to act as an output.
Table 81. Register 0x81—Interrupt Status Register 4 (Power-On Default = 0x00)
Bit No.
[2:0]
[3]
Mnemonic
RES
PECI1
R/W
Read-only
Read-only
[4]
PECI2
Read-only
[5]
PECI3
Read-only
[6]
IMON
Read-only
[7]
VTT
Read-only
Description
Reserved.
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value from PECI Client
Address 0x31. This bit is cleared on a read of the status register only if the error condition has subsided.
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value from PECI Client
Address 0x32. This bit is cleared on a read of the status register only if the error condition has subsided.
A Logic 1 indicates that the PECI high or low limit has been exceeded by the PECI value from PECI Client
Address 0x33. This bit is cleared on a read of the status register only if the error condition has subsided.
A Logic 1 indicates that the IMON high or low limit has been exceeded. This bit is cleared on a read of the
status register only if the error condition has subsided.
A Logic 1 indicates that the VTT high or low limit has been exceeded. This bit is cleared on a read of the
status register only if the error condition has subsided.
Table 82. Register 0x82—Interrupt Mask Register 3 (Power-On Default = 0x00)1
Bit No.
[0]
[1]
[2]
[3]
[6:4]
[7]
1
Mnemonic
PECI0
DATA
COMM
OVT
RES
OOL
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
A Logic 1 masks SMBALERT assertions for out-of-limit conditions on PECI0.
A Logic 1 masks SMBALERT assertions for PECI data errors.
A Logic 1 masks SMBALERT assertions for PECI communications errors.
OVT = 1 masks SMBALERT for overtemperature THERM conditions.
Reserved.
OOL = 1 masks SMBALERT assertions when the OOL status bit is set.
Note that the OOL mask bit is independent of the individual mask bits of Interrupt Mask 4 register
(0x83). Therefore, if the intention is to mask SMBALERT assertions for any of the Status Register 4 bits,
OOL must also be masked.
If the mask bits in Register 0x82 are set, it is also necessary to set the OOL mask bit in Register 0x75 to ensure the SMBALERT output is not asserted.
Rev. 0 | Page 71 of 76
ADT7490
Table 83. Register 0x83—Interrupt Mask Register 4 (Power-On Default = 0x00)1
Bit No.
[2:0]
[3]
[4]
[5]
[6]
[7]
1
Mnemonic
RES
PECI1
PECI2
PECI3
IMON
VTT
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
Reserved.
A Logic 1 masks ALERT assertions for out-of-limit conditions on PECI1.
A Logic 1 masks ALERT assertions for out-of-limit conditions on PECI2.
A Logic 1 masks ALERT assertions for out-of-limit conditions on PECI3.
A Logic 1 masks ALERT assertions for out-of-limit conditions on IMON.
A Logic 1 masks ALERT assertions for out-of-limit conditions on VTT.
If the mask bits in Register 0x83 are set, it is also necessary to set the OOL mask bit in Register 0x82 to ensure the SMBALERT output is not asserted.
Table 84. VTT, IMON Limit Registers
R/W1
R/W
R/W
R/W
R/W
Register Address
0x84
0x85
0x86
0x87
1
Description
VTT Low Limit
IMON Low Limit
VTT High Limit
IMON High Limit
Power-On Default
0x00
0x00
0xFF
0xFF
These registers becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 85. Register 0x88—PECI Configuration Register 2 (Power-On Default = 0x00)
Bit No.
[2:0]
[3]
Mnemonic
RES
DOM3
R/W1
R/W
R/W
[4]
DOM2
R/W
[5]
DOM1
R/W
[7:6]
#CPU
R/W
1
Description
Reserved.
CPU Domain Count Information. Set to 0 indicates that CPU 4 associated with the PECI3 reading has a
single domain (default). Set to 1 indicates that the system CPU4 contains two domains.
CPU Domain Count Information. Set to 0 indicates that CPU 3 associated with the PECI2 reading has a
single domain (default). Set to 1 indicates that the system CPU3 contains two domains.
CPU Domain Count Information. Set to 0 indicates that CPU 2 associated with the PECI1 reading has a
single domain (default). Set to 1 indicates that the system CPU2 contains two domains.
CPU Count. These bits indicate the number of CPUs in the system, which provide PECI thermal
information to the ADT7490.
00 = 1 CPU (default); indicates that PECI0 data is available from CPU 1 at Address 0x30.
01 = 2 CPUs; indicates that PECI0 data is available from CPU1 at Address 0x30 and PECI1 data is
available from CPU 2 at Address 0x31.
10 = 3 CPUs; indicates that PECI0 data is available from CPU1 at Address 0x30, PECI1 data is available
from CPU 2 at Address 0x31 and PECI2 data is available from CPU 3 at Address 0x32.
11 = 4 CPUs; indicates that PECI0 data is available from CPU1 at Address 0x30, PECI1 data is available
from CPU 2 at Address 0x31, PECI2 data is available from CPU 3 at Address 0x32 and PECI3 data is
available from CPU 4 at Address 0x33.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Table 86. Operating Point Registers1, 2
Register Address
0x8A
0x8B
0x8C
0x8D
1
2
3
R/W3
R/W
R/W
R/W
R/W
Description
PECI operating point register
Remote 1 operating point register (default = 100°C).
Local temperature operating point register (default = 100°C).
Remote 2 operating point register (default = 100°C).
Power-On Default
0xFB
0x64
0x64
0x64
These registers set the target operating point for each temperature channel when the dynamic TMIN control feature is enabled.
The fans being controlled are adjusted to maintain temperature about an operating point.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Rev. 0 | Page 72 of 76
ADT7490
Table 87. Register 0x8E—Dynamic TMIN Control Register 1 (Power-On Default = 0x00)
Bit No.
[0]
Mnemonic
CYR2
R/W1
R/W
[1]
VCCPLO
R/W
[2]
PHTR1
Read/write
[3]
PHTL
R/W
[4]
PHTR2
R/W
[5]
R1T
R/W
[6]
LT
R/W
[7]
R2T
R/W
1
Description
MSB of 3-Bit Remote 2 Cycle Value. The other two bits of the code reside in the Dynamic TMIN Control
Register 2 (0x8F). These three bits define the delay time between making subsequent TMIN
adjustments in the control loop in terms of the number of monitoring cycles. The system has
associated thermal time constants that need to be found to optimize the response of fans and the
control loop.
VCCPLO = 1. When the power is supplied from 3.3 V STANDBY and the core voltage (VCCP) drops below
its VCCP low limit value (0x46), the following occurs:
Status Bit 1 in Status Register 1 is set.
SMBALERT is generated, if enabled.
PROCHOT monitoring is disabled.
Dynamic TMIN control is disabled.
The device is prevented from entering shutdown.
Everything is re-enabled once VCCP increases above the VCCP low limit.
PHTR1 = 1 copies the Remote 1 current temperature to the Remote 1 operating point register if
THERM is asserted. The operating point contains the temperature at which THERM is asserted,
allowing the system to run as quietly as possible without affecting system performance.
PHTR1 = 0 ignores any THERM assertions on the THERM pin. The Remote 1 operating point register
reflects its programmed value.
PHTL = 1 copies the local channel’s current temperature to the local operating point register if THERM
is asserted. The operating point contains the temperature at which THERM is asserted. This allows the
system to run as quietly as possible without affecting system performance.
PHTL = 0 ignores any THERM assertions on the THERM pin. The local temperature operating point
register reflects its programmed value.
PHTR2 = 1 copies the Remote 2 current temperature to the Remote 2 operating point register if
THERM is asserted. The operating point contains the temperature at which THERM is asserted,
allowing the system to run as quietly as possible without affecting system performance.
PHTR2 = 0 ignores any THERM assertions on the THERM pin. The Remote 2 operating point register
reflects its programmed value.
R1T = 1 enables dynamic TMIN control on the Remote 1 temperature channel. The chosen TMIN value is
dynamically adjusted based on the current temperature, operating point, and high and low limits for
this zone.
R1T = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the channel behaves
as described in the Automatic Fan Control Overview section.
LT = 1 enables dynamic TMIN control on the local temperature channel. The chosen TMIN value is
dynamically adjusted based on the current temperature, operating point, and high and low limits for
this zone.
LT = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the channel behaves
as described in the Automatic Fan Control Overview section.
R2T = 1 enables dynamic TMIN control on the Remote 2 temperature channel. The chosen TMIN value is
dynamically adjusted based on the current temperature, operating point, and high and low limits for
this zone.
R2T = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted, and the channel behaves
as described in the Automatic Fan Control Overview section.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Rev. 0 | Page 73 of 76
ADT7490
Table 88. Register 0x8F—Dynamic TMIN Control Register 2 (Power-On Default = 0x00)
Bit No.
[2:0]
Mnemonic
CYR1
R/W1
R/W
[5:3]
CYL
R/W
[7:6]
CYR2
R/W
1
Description
3-Bit Remote 1 Cycle Value. These three bits define the delay time between making subsequent TMIN
adjustments in the control loop for the Remote 1 channel in terms of number of monitoring cycles.
The system has associated thermal time constants that need to be found to optimize the response of
fans and the control loop.
Bit Code
Decrease Cycle
Increase Cycle
000
8 cycles (1 sec)
16 cycles (2 sec)
001
16 cycles (2 sec)
32 cycles (4 sec)
010
32 cycles (4 sec)
64 cycles (8 sec)
011
64 cycles (8 sec)
128 cycles (16 sec)
100
128 cycles (16 sec)
256 cycles (32 sec)
101
256 cycles (32 sec)
512 cycles (64 sec)
110
512 cycles (64 sec)
1024 cycles (128 sec)
111
1024 cycles (128 sec)
2048 cycles (256 sec)
3-Bit Local Temperature Cycle Value. These three bits define the delay time between making
subsequent TMIN adjustments in the control loop for the local temperature channel in terms of
number of monitoring cycles. The system has associated thermal time constants that need to be
found to optimize the response of fans and the control loop.
Bit Code
Decrease Cycle
Increase Cycle
000
8 cycles (1 sec)
16 cycles (2 sec)
001
16 cycles (2 sec)
32 cycles (4 sec)
010
32 cycles (4 sec)
64 cycles (8 sec)
011
64 cycles (8 sec)
128 cycles (16 sec)
100
128 cycles (16 sec)
256 cycles (32 sec)
101
256 cycles (32 sec)
512 cycles (64 sec)
110
512 cycles (64 sec)
1024 cycles (128 sec)
111
1024 cycles (128 sec)
2048 cycles (256 sec)
2 LSBs of 3-Bit Remote 2 Cycle Value. The MSB of the 3-bit code resides in the Dynamic TMIN Control
Register 1 (Register 0x8E). These three bits define the delay time between making subsequent TMIN
adjustments in the control loop for the Remote 2 channel in terms of number of monitoring cycles.
The system has associated thermal time constants that need to be found to optimize the response of
fans and the control loop.
Bit Code
Decrease Cycle
Increase Cycle
000
8 cycles (1 sec)
16 cycles (2 sec)
001
16 cycles (2 sec)
32 cycles (4 sec)
010
32 cycles (4 sec)
64 cycles (8 sec)
011
64 cycles (8 sec)
128 cycles (16 sec)
100
128 cycles (16 sec)
256 cycles (32 sec)
101
256 cycles (32 sec)
512 cycles (64 sec)
110
512 cycles (64 sec)
1024 cycles (128 sec)
111
1024 cycles (128 sec)
2048 cycles (256 sec)
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Rev. 0 | Page 74 of 76
ADT7490
Table 89. Register 0x90—Dynamic TMIN Control Register 3 (Power-On Default = 0x00)
Bit No.
[2:0]
[5:3]
Mnemonic
RES
CYP
R/W1
Reserved
R/W
[6]
PHTP
R/W
[7]
PECI
R/W
1
Description
Reserved.
3-Bit PECI Temperature Cycle Value. These three bits define the delay time between making
subsequent TMIN adjustments in the control loop for the PECI temperature channels in terms of
number of monitoring cycles. The system has associated thermal time constants that need to be
found to optimize the response of fans and the control loop.
Bit Code
Decrease Cycle
Increase Cycle
000
8 cycles (1 sec)
16 cycles (2 sec)
001
16 cycles (2 sec)
32 cycles (4 sec)
010
32 cycles (4 sec)
64 cycles (8 sec)
011
64 cycles (8 sec)
128 cycles (16 sec)
100
128 cycles (16 sec)
256 cycles (32 sec)
101
256 cycles (32 sec)
512 cycles (64 sec)
110
512 cycles (64 sec)
1024 cycles (128 sec)
111
1024 cycles (128 sec)
2048 cycles (256 sec)
PHTR1 = 1 copies the PECI0 current reading to the PECI operating point register if THERM is asserted.
The operating point contains the temperature at which THERM is asserted, allowing the system to run
as quietly as possible without affecting system performance.
PHTR1 = 0 ignores any THERM assertions on the THERM pin. The PECI operating point register reflects
its programmed value.
PECI = 1 enables dynamic TMIN control on the PECI temperature channel. The chosen TMIN value is
dynamically adjusted based on the current temperature, operating point, and high and low limits for
this zone.
PECI = 0 disables dynamic TMIN control. The TMIN value chosen is not adjusted and the channel behaves
as described in the Automatic Fan Control Overview section.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any subsequent attempts to write to this register fail.
Table 90. Register 0x94—PECI0 Temperature Offset (Power-On Default = 0x00)
Bit No.
[7:0]
1
R/W1
R/W
Description
Allows a temperature offset to be automatically applied to the PECI0 channel measurements. The programmable
offset range is from −63°C to +127°C with 1°C resolution.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 91. Register 0x95—PECI1 Temperature Offset (Power-On Default = 0x00)
Bit No.
[7:0]
1
R/W1
R/W
Description
Allows a temperature offset to be automatically applied to the PECI1 channel measurements. The programmable
offset range is from −63°C to +127°C with 1°C resolution.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 92. Register 0x96—PECI2 Temperature Offset (Power-On Default = 0x00)
Bit No.
[7:0]
1
R/W1
R/W
Description
Allows a temperature offset to be automatically applied to the PECI2 channel measurements. The
programmable offset range is from −63°C to +127°C with 1°C resolution.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Table 93. Register 0x97—PECI3 Temperature Offset (Power-On Default = 0x00)
Bit No.
[7:0]
1
R/W1
R/W
Description
Allows a temperature offset to be automatically applied to the PECI3 channel measurements. The programmable
offset range is from −63°C to +127°C with 1°C resolution.
This register becomes read-only when the Configuration Register 1 (0x40) LOCK bit is set to 1. Any further attempts to write to this register have no effect.
Rev. 0 | Page 75 of 76
ADT7490
OUTLINE DIMENSIONS
0.345
0.341
0.337
24
13
0.158
0.154
0.150
1
12
0.244
0.236
0.228
PIN 1
0.069
0.053
0.065
0.049
0.010
0.004
0.025
BSC
COPLANARITY
0.004
0.012
0.008
SEATING
PLANE
0.010
0.006
8°
0°
0.050
0.016
COMPLIANT TO JEDEC STANDARDS MO-137AE
Figure 63. 24-Lead Shrink Small Outline Package [QSOP]
(RQ-24)
Dimensions shown in inches
ORDERING GUIDE
Model
ADT7490ARQZ 1
ADT7490ARQZ-REEL1
ADT7490ARQZ-REEL71
EVAL-ADT7490EBZ1
1
Termperature Range
–40°C to +125°C
–40°C to +125°C
–40°C to +125°C
Package Description
24-Lead QSOP
24-Lead QSOP
24-Lead QSOP
Evaluation Board
Z = RoHS Compliant Part.
©2007 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D06789-0-7/07(0)
Rev. 0 | Page 76 of 76
Package Option
RQ-24
RQ-24
RQ-24