FST BEAB 5 x 20mm Time Lag Fuses – Low Breaking Capacity Built according to IEC 127-2/3, EN 60127, SEV 1064, DIN/VDE 0820 part 1, DIN 41662, BS 4265, and SEMKO 104-1976, with support by UL 198G. Series SP & SPT recommended if the short circuit current through the fuse- link is more than 35A or 10 x In , whichever is greater (CENELEC Jan 1, 1993). Approvals: UL recognition 32mA-16A* File #E41599 CSA acceptance 32mA-16A* File #LR51172 VDE approval 32mA-6.3A File #50910 SEMKO approval 32mA-6.3A File #51550 SEV approval 32mA-6.3A File BSI license 125mA-6.3A numbers CB certification 32-40mA, 125mA-6.3A on request BEAB approval 32-40mA, 125mA-6.3A * fuses with pigtail leads approved up to 8A (factory assembled only) Fusing time in seconds ts NEW New version with gold plated caps for direct pcb mounting cUL recognition 1A-16A/250V** pending VDE approval 1A-16A/250V** pending ** Contact Schurter for part numbers Time Current Characteristics n • In 1.5 • In 2.1 • In 2.75 • In 4 • In 10 • In min. max. min. max. min. max. min. max. 20mA – 100mA 60 min. 2 min.* 200 ms* 10 s* 40 ms 3s 10 ms 300 ms 125mA – 20A 60 min. 2 min. 600 ms 10 s 150 ms 3s 20 ms 300 ms SEV rated current In * These values are not guaranteed at 20mA Multiple of rated current In Spool With pigtail leads Tape max. IEC 127 Watts 35A / 250 V / 50 Hz / p.f. 1 10 • In 250V / 50 Hz / p.f. 1 5000 4000 3500 3000 3000 2500 2000 1900 1500 1300 1100 1000 900 300 250 150 150 150 150 120 100 100 100 100 typical Schurter mV 2700 3000 2100 950 1300 1100 1000 565 415 270 210 170 150 160 160 120 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 max. Schurter Watts 0.4 0.5 0.5 0.6 0.7 0.8 1.1 1.2 1.3 1.6 1.8 typical Schurter Watts 0.1 0.2 0.2 0.125 0.2 0.3 0.155 0.2 0.185 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.2 0.3 0.3 0.3 0.3 0.4 0.5 0.8 0.9 1.0 1.3 1.3 2.5 3.3 4.2 A 2s 0.0012 0.0019 0.0027 0.0363 0.0401 0.0570 0.107 0.064 0.230 0.256 0.238 0.544 0.768 3.0 4.35 3.85 3.30 5.50 7.45 10.5 16 21.9 47 68.3 102 190 275 520 750 1638 3057 Approvals • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • BEAB A~ max. IEC 127 mV Pre-arcing I 2 t at 10 • ln CB Power dissipation at 1.5 • In BSI Voltage drop at In VDE mA / A / V~ 20 mA*/ 250V 32 mA / 250V 40 mA / 250V 50 mA / 250V 63 mA / 250V 80 mA / 250V 100 mA / 250V 125 mA / 250V 160 mA / 250V 200 mA / 250V 250 mA / 250V 315 mA / 250V 400 mA / 250V 500 mA / 250V 630 mA / 250V 800 mA / 250V 1 A / 250V 1.25 A / 250V 1.4 A*/ 250V 1.6 A / 250V 2 A / 250V 2.5 A / 250V 3.15 A / 250V 4 A / 250V 5 A / 250V 6.3 A / 250V 8 A* / 250V 10 A* / 250V 12.5 A* / 250V 16 A* / 250V 20 A* / 250V Breaking capacity CSA Series FST 0034.3101 0034.3102 0034.3103 0034.3104 0034.3105 0034.3106 0034.3107 0034.3108 0034.3109 0034.3110 0034.3111 0034.3112 0034.3113 0034.3114 0034.3115 0034.3116 0034.3117 0034.3118 0034.3165* 0034.3119 0034.3120 0034.3121 0034.3122 0034.3123 0034.3124 0034.3125 0034.3126 0034.3127 0034.3128 0034.3129 0034.3130 Rated current / rated voltage UL Order Numbers SEMKO according to IEC 286-1 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • *Not addressed in the standards; 1.4A SEMKO approved only. For pigtail fuses packaged loose: reference .PT after part number (e.g. 0034.3101.PT) For pigtail fuses on 1,000-piece tape and reel: reference .TR after part number (e.g. 0034.3101.TR) Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail [email protected] • Website http://www.schurterinc.com 149