TGS BTA26-600B 25a triac Datasheet

TIGER ELECTRONIC CO.,LTD
Product specification
BTA/BTB26-600B
25A TRIACS
GENERAL DESCRIPTION
Available either in through-hole or surface-mount packages, the BTA/BTB26 - 600C triac series is
suitable for general purpose AC switching. They can be used as an ON/OFF function in applications
such as static relays, heating regulation, induction motor starting circuits... or for phase control
operation in light dimmers, motor speed controllers, ...
The snubberless versions (BTA/BTB...W series) are specially recommended for use on
inductive loads, thanks to their high commutation performances. By using an internal ceramic pad,
the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL standards.
O
ABSOLUTE MAXIMUM RATINGS ( Ta = 25 C)
PARAMETER
Symbol
Value
Unit
Repetitive peak off-state voltages
VDRM
600
V
peak off-state reverse voltages
VRRM
600
V
IT
25.0
A
ITSM
260
A
Tj
110
o
Tstg
-45~150
o
RMS on-state current
Non-repetitive peak on-state current
Max. Operating Junction Temperature
Storage Temperature
A1 A2 G
C
TO-3P
C
O
ELECTRICAL CHARACTERISTICS ( Ta = 25 C)
PARAMETER
Symbol
Test Conditions
Repetitive peak off-state
voltages
VDRM
ID=0.1mA
Repetitive peak off-state
current
IDRM
VDRM=520V
On-state voltage
VTM
IT=35A
Holding current
IH
T2+G-
Current
T2-G-
Max
600
IT=0.5A,IGT=25mA
T2+G+
Gate trigger
Min.
V
10
uA
1.55
V
25
mA
50
IGT
50
VAK=12V
RL=30
mA
50
T2-G+
100
T2+G+
1.3
Gate trigger
T2+G-
Voltage
T2-GT2-G+
Unit
VGT
VD=12V
RL=30
1.3
1.3
1.3
V
Similar pages