BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters FEATURES · 0...-1 to 0...350 bar, 0...-15 to 0...5000 psi gage1 or absolute11 · For corrosive media · Flush mount versions · 0...10 V, 1...6 V, 0...20 mA, 4...20 mA output · Field interchangeable · For harsh environments MEDIA COMPATIBILITY Wetted materials: stainless steel 1.4404 (316L), NBR12 ELECTRICAL CONNECTION Housing: stainless steel 1.4404 (316L), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1 0...10 V, 1...6 V output +Vs sensor 13 to 30 V 1 Vout 3 -Vs 2 SPECIFICATIONS9,10 V GND Maximum ratings 0...20 mA output Supply voltage (reverse polarity protection) 13...30 V BTE(M)/PTU6...0, ...1 12...36 V BTE(M)/PTU6...4, ...52 Maximum load current BTE(M)/PTU6...0, ...1 Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock 3 Proof pressure December 2008 / 102 sensor 10 mA +Vs 1 Iout 3 -Vs 2 12 to 36 V RL V GND -55 to 100°C -40 to 100°C 0 to 70°C 4...20 mA output 0 - 95 %RH 10 gRMS 50 g sensor +Vs 1 N/C 3 -Vs 2 12 to 36 V V RL GND 2 x rated pressure 1/8 www.sensortechnics.com BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters COMMON PERFORMANCE CHARACTERISTICS1 Characteristics Operating pressure Thermal effects (0 to 70°C)4 200/300 mbar, 3/5 psi only Thermal effects (-40 to 0°C, 70 to 100°C) Min. Typ. Max. Unit BTEM6200... BTEM6350... 0 0 200 350 mbar BTE6001... BTE6N01... BTE6P01... BTE6002... BTE6005... BTE6010... BTE6016... BTE6035... BTE6070... BTE6350... 0 -1 -1 0 0 0 0 0 0 0 1 +1 0 2 5 10 16 35 70 350 bar PTU6003... PTU6005... PTU6015... PTU6N15... PTU6P15... PTU6030... PTU6100... PTU6250... PTU6500... PTU61K0... PTU65K0... 0 0 0 -15 -15 0 0 0 0 0 0 3 5 15 +15 0 30 100 250 500 1000 5000 p si Offset Span 0.01 0.01 Offset Span Offset Span 0.03 0.03 0.06 0.04 %FSO/°C 0.03 0.03 Non-linearity and hysteresis (BSL)5 ±0.1 Repeatability ±0.1 Long term stability6 ±0.2 Output noise (0 < f < 1 kHz) ±0.04 Response time (10 to 90 %) 1 ms 0.05 0.05 %FSO/V Power supply rejection December 2008 / 102 Offset Span ±0.5 %FSO 2/8 www.sensortechnics.com BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters INDIVIDUAL PERFORMANCE CHARACTERISTICS1 0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 BTE/PTU6N... all others BTE/PTU6N... all others Min. Typ. Max. Unit 4.85 -0.15 4.9 9.9 5.0 0 5.0 10.0 5.15 0.15 5.1 10.1 V 50 Ω Output impedance Power consumption (no load) 100 mW 1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Typ. Max. Unit 3.35 0.85 2.4 4.9 3.5 1.0 2.5 5.0 3.65 1.15 2.6 5.1 V Output impedance 6.0 50 Ω Power consumption (no load) 100 Zero pressure offset Full scale span7 BTE/PTU6N... all others BTE/PTU6N... all others mW 4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 BTE/PTU6N... all others BTE/PTU6N... all others Min. Typ. Max. Unit 11.85 3.85 7.9 15.9 12.0 4.0 8.0 16.0 12.15 4.15 8.1 16.1 mA Output impedance 0.1 Ω Power consumption (IL = 20 mA) 260 mW 0...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 BTE/PTU6N... all others BTE/PTU6N... all others Min. Typ. Max. Unit 9.85 -0.15 9.9 19.9 10.0 0 10.0 20.0 10.15 0.15 10.1 20.1 mA Output impedance 0.1 Ω Power consumption (IL = 20 mA) 260 mW December 2008 / 102 3/8 www.sensortechnics.com BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters Specification notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. Long term stability is the change in output after one year or 1 million pressure cycles. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. Test are in accordance with EN61000-6-2, April 1999. CE-labelling is in accordance with 89/336/EEC. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. Other sealing materials are available on request. ELECTROMAGNETIC CAPABILITY8 Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields Test conditions Criterion Interference EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A <1 %FSO 80 % AMC (1 kHz) EN61000-4-4: Grade 3, ±2 kV B <1 %FSO EN61000-4-2: Grade 4, ±8 kV, contact discharge EN61000-4-6: Grade 3, 0.15 to 80 MHz 10 V, 80 % AMC (1 kHz) B <1 %FSO A <1 %FSO LOAD LIMITATION RECOMMENDED ACCESSORY 0...20 mA output version 4...20 mA output version Plug DIN EN 175301-803 A and profile washer included in delivery. For a complete connector/cable assembly use order no. ZK000110-x (x=cable lenghts in m). 1400 Ohm 1200 50 1000 34 800 600 operating range Profile washer 400 M3 31 200 0 5 10 15 20 25 30 35 V supply voltage December 2008 / 102 dimensions in mm Note: For proper function of all gage devices the gage port must be vented to the atmosphere through the connector/cable assembly. 4/8 www.sensortechnics.com BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters OUTPUT CHARACTERISTICS 1...6 V output version 0...10 V output version 10 Vout V 9 10 Vout 9 V 8 8 BTE/PTU6N... 7 7 6 6 5 5 4 all others BTE/PTU6P... 4 3 3 2 2 1 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 % operating pressure 4...20 mA output version BTE/PTU6P... all others -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 % operating pressure 0...20 mA output version 20 20 Iout 18 mA 16 BTE/PTU6N... Iout 18 mA 16 14 14 12 12 10 BTE/PTU6N... BTE/PTU6P... 8 all others 4 2 2 December 2008 / 102 0 +20 +40 +60 +80 +100 % operating pressure all others 6 4 -100 -80 -60 -40 -20 BTE/PTU6N... 10 8 6 BTE/PTU6P... -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 % operating pressure 5/8 www.sensortechnics.com BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters OUTLINE DRAWING BTE6... (for pressure ranges < 35 bar) 25.0 (0.98) 17.0 (0.67) NOM 83.0 (NOM 3.27) 12.0 (0.47) 1 vent hole 8.5 (0.33) 27.0 (1.06) diam. 6.0 (0.24) G1/2" (BSP) HEX27 ( 1 1/8) 3 2 mass: 230 g 1 dimensions in mm (inches) BTE6... (for pressure ranges ≥ 35 bar) 25.0 (0.98) 12.0 (0.47) 1 vent hole 31.5 (1.24) 6.0 (0.24) 27.0 (1.06) diam. 3 G1/2" (BSP) HEX27 ( 1 1/8) 17.0 (0.67) NOM 106.0 (NOM 4.17) 2 mass: 280 g 1 dimensions in mm (inches) BTE6...-FL NOM 86.5 (NOM 3.41) NOM 13.0 (NOM 0.51) 12.0 (0.47) vent hole 1 mass: 250 g December 2008 / 102 27.0 (1.06) diam. 23.0 (0.91) diam. 3 G3/4" (BSP) HEX32 ( 15/16) NOM 3.0 (NOM 0.12) 12.0 (0.47) WARNING Do not touch diaphragm 2 1 dimensions in mm (inches) 6/8 www.sensortechnics.com BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters OUTLINE DRAWING PTU6... (for pressure ranges < 500 psi) 17.0 (0.67) NOM 83.0 (NOM 3.27) 12.0 (0.47) 1 vent hole 3 27.0 (1.06) diam. 1/4"-18 NPT HEX27 ( 1 1/8) 8.5 (0.33) 2 mass: typ. 280 g 1 dimensions in mm (inches) PTU6... (for pressure ranges ≥ 500 psi) 17,0 (0.67) NOM 106.0 (NOM 4.17) 12.0 (0.47) 1 vent hole 3 27.0 (1.06) diam. 1/4" - 18 NPT HEX27 ( 1 1/8) 31.5 (1.24) 2 mass: typ. 280 g 1 dimensions in mm (inches) PTU6...-FL 12.7 (0.5) 2.7 (0.1) NOM 86.5 (NOM 3.41) 12.0 (0.47) 12.0 (0.47) mass: typ. 190 g December 2008 / 102 27.0 (1.06) diam. Ø22,5 ± 0,05 3 1-12UNF HEX32 ( 15/16) 1 vent hole WARNING Do not touch diaphragm 2 1 dimensions in mm (inches) 7/8 www.sensortechnics.com BTE6000 / PTU6000 Series Precision stainless steel pressure transmitters ORDERING INFORMATION (European standard devices) 0...10 V output Operating pressure 0 to 1 bar absolute ½ " manometer thread BTE6001A0 1...6 V output flush mount ½ " manometer thread BTE6001A0-FL BTE6001A1 4...20 mA output flush mount ½ " manometer thread BTE6001A1-FL BTE6001A4 0...20 mA output flush mount ½ " manometer thread flush mount BTE6001A4-FL BTE6001A5 BTE6001A5-FL 0 to 2 bar absolute BTE6002A0 BTE6002A0-FL BTE6002A1 BTE6002A1-FL BTE6002A4 BTE6002A4-FL BTE6002A5 BTE6002A5-FL 0 to 5 bar absolute BTE6005A0 BTE6005A0-FL BTE6005A1 BTE6005A1-FL BTE6005A4 BTE6005A4-FL BTE6005A5 BTE6005A5-FL 0 to 10 bar absolute BTE6010A0 BTE6010A0-FL BTE6010A1 BTE6010A1-FL BTE6010A4 BTE6010A4-FL BTE6010A5 BTE6010A5-FL 0 to 16 bar absolute BTE6016A0 BTE6016A0-FL BTE6016A1 BTE6016A1-FL BTE6016A4 BTE6016A-FL BTE6016A5 BTE6016A5-FL 0 to 35 bar absolute BTE6035A0 --- BTE6035A1 --- BTE6035A4 --- BTE6035A5 --- 0 to 70 bar absolute BTE6070A0 --- BTE6070A1 --- BTE6070A4 --- BTE6070A5 --- 0 to 350 bar absolute BTE6350A0 --- BTE6350A1 --- BTE6350A4 --- BTE6350A5 --- 0 to 35 bar sealed gage BTE6035G0 --- BTE6035G1 --- BTE6035G4 --- BTE6035G5 --- 0 to 70 bar sealed gage BTE6070G0 --- BTE6070G1 --- BTE6070G4 --- BTE6070G5 --- 0 to 350 bar sealed gage BTE6350G0 --- BTE6350G1 --- BTE6350G4 --- BTE6350G5 --- 0 to 200 mbar gage BTEM6200G0 --- BTEM6200G1 --- BTEM6200G4 --- BTEM6200G5 --- 0 to 350 mbar gage BTEM6350G0 --- BTEM6350G1 --- BTEM6350G4 --- BTEM6350G5 --- 0 to 1 bar gage BTE6001G0 BTE6001G0-FL BTE6001G1 BTE6001G1-FL BTE6001G4 BTE6001G4-FL BTE6001G5 BTE6001G5-FL 0 to -1 bar gage BTE6P01G0 BTE6P01G0-FL BTE6P01G1 BTE6P01G1-FL BTE6P01G4 BTE6P01G4-FL BTE6P01G5 BTE6P01G5-FL BTE6N01G5-FL 0 to ±1 bar gage BTE6N01G0 BTE6N01G0-FL BTE6N01G1 BTE6N01G1-FL BTE6N01G4 BTE6N01G4-FL BTE6N01G5 0 to 2 bar gage BTE6002G0 BTE6002G0-FL BTE6002G1 BTE6002G1-FL BTE6002G4 BTE6002G4-FL BTE6002G5 BTE6002G5-FL 0 to 5 bar gage BTE6005G0 BTE6005G0-FL BTE6005G1 BTE6005G1-FL BTE6005G4 BTE6005G4-FL BTE6005G5 BTE6005G5-FL 0 to 10 bar gage BTE6010G0 BTE6010G0-FL BTE6010G1 BTE6010G1-FL BTE6010G4 BTE6010G4-FL BTE6010G5 BTE6010G5-FL 0 to 16 bar gage BTE6016G0 BTE6016G0-FL BTE6016G1 BTE6016G1-FL BTE6016G4 BTE6016G4-FL BTE6016G5 BTE6016G5-FL (American standard devices) Operating pressure 0...10 V output 4...20 mA output ¼ " N PT flush mount ¼ " N PT flush mount 0 to 15 psi absolute PTU6015A0 PTU6015A0-FL PTU6015A4 PTU6015A4-FL PTU6030A4-FL 0 to 30 psi absolute PTU6030A0 PTU6030A0-FL PTU6030A4 0 to 100 psi absolute PTU6100A0 PTU6100A0-FL PTU6100A4 PTU6100A4-FL 0 to 250 psi absolute PTU6250A0 PTU6250A0-FL PTU6250A4 PTU6250A4-FL --- 0 to 500 psi absolute PTU6500A0 --- PTU6500A4 0 to 1000 psi absolute PTU61K0A0 --- PTU61K0A4 --- 0 to 5000 psi absolute PTU65K0A0 --- PTU65K0A4 --- 0 to 500 psi sealed gage PTU6500S0 --- PTU6500S4 --- 0 to 1000 psi sealed gage PTU61K0S0 --- PTU61K0S4 --- 0 to 5000 psi sealed gage PTU65K0S0 --- PTU65K0S4 --- 0 to 3 psi gage PTU6003G0 --- PTU6003G4 --- 0 to 5 psi gage PTU6005G0 --- PTU005G4 --- 0 to 15 psi gage PTU6015G0 PTU6015G0-FL PTU6015G4 PTU6015G4-FL 0 to -15 psi gage PTU6P15G0 PTU6P15G0-FL PTU6P15G4 PTU6P15G4-FL 0 to ±15 psi gage PTU6N15G0 PTU6N15G0-FL PTU6N15G4 PTU6N15G4-FL PTU6030G4-FL 0 to 30 psi gage PTU6030G0 PTU6030G0-FL PTU6030G4 0 to 100 psi gage PTU6100G0 PTU6100G0-FL PTU6100G4 PTU6100G4-FL 0 to 250 psi gage PTU6250G0 PTU6250G0-FL PTU6250G4 PTU6250G4-FL Note: Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. December 2008 / 102 8/8 www.sensortechnics.com