MPD C4004ERW C4000erw sery Datasheet

C4000ERW Series
Compact, 2:1 Input
40W, Single Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 40W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Compact 2 x 2 In. Case
• -40ºC to +60ºC Operation
• >1.0 MHour MTBF
• Remote ON/OFF
• Industry Standard Pin-Out
Input
Parameter
Input Voltage Range
Under Voltage Shutdown
Input Filter
Start Up Time
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
8.0
24 VDC Input 16.0
48 VDC Input 33.0
␲ (Pi) Filter
See Note 1
Typ.
12.0
24.0
48.0
Conditions
Typ.
±1.0
±0.2
±0.5
75
Max.
18.0
36.0
75.0
9.0
17.8
36.0
Units
2.0
A
Max.
Units
%
%
%
mV P - P
%
% Vout
µSec
%
%/°C
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Output Power Protection
Over Voltage Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Min.
For Vin Min to Max
Iout = 10% to 100%
120
110
200
25% Load Step Change
150
150
130
500
±5.0
±0.02
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Over Temperature Protection
Remote On/Off (Note 3)
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Conditions
60 Seconds
500 VDC
100 kHz, 0.1V
Min.
1,500
1,000
Max.
2,000
300
115
Case Temperature
Conditions
Typ.
Min.
3.5
-0.0
Units
VDC
M⍀
pF
kHz
°C
Typ.
Max.
Units
12.0
VDC
1.2
VDC
1
mA
Referenced to Negative Input (pin 2)
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+60
+125
Units
°C
°C
95
%
2.0 x 2.0 x 0.42 Inches (50.8 x 50.8 x 10.6 mm)
Metal with Non-Conductive Base
2.19 Oz (60g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1,000
Typ.
Max.
Units
kHours
Min.
-0.7
-0.7
-0.7
Typ.
Max.
20.0
40.0
80.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
C4001ERW
C4002ERW
C4003ERW
C4004ERW
C4011ERW
C4012ERW
C4013ERW
C4014ERW
C4021ERW
C4022ERW
C4023ERW
C4024ERW
Voltage (VDC)
Nominal
Range
12
12
12
12
24
24
24
24
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
Capacitive
Load
(µF Max)
21,000
13,600
2,360
1,510
21,000
13,600
2,360
1,510
21,000
13,600
2,360
1,510
Output
Efficiency
(%, Typ)
Current (mA)
Voltage Current
Current
Full-Load No-Load (VDC) (mA, Max) (mA, Min)
2,558
3,876
3,876
3,831
1,264
1,873
1,894
1,873
625
926
926
926
20
20
20
20
15
15
15
15
10
10
10
10
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
Notes:
1. When measuring output ripple, it is recommended that an external 10.0 µF ceramic capacitor
be placed from the +Vout pin to the -Vout pin. For noise sensitive applications, the use of
47 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to
100%.
3. The Remote On/Off Control input (Pin 3) is referenced to -Vin (Pin 1). Connection to the
pin should be made through a 1k⍀ resistor and diode (1N4148). If it is not used, the
control pin should be left open.
4. Operation at no-load will not damage these units. However, they may not meet all specifications.
5. The +sense and -sense connections will compensate for up to 5% of Vout. When not used,
they should be connected directly to the appropriate output pin (+sense to +Vout and -sense
to -Vout).
6. To improve performance and stability, a simple external LC filter can be added to the unit
input. Typical component values would be 1.0 µH/10A & 1,000 µF/25V for 12V input models;
2.2 µH/10A & 1,000 µF/50V for 24V input models; and 74.7 µH/5A & 1,000 µF/100V for 48V
input models.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the
table above for the correct rating.
8,000
8,000
3,300
2,666
8,000
8,000
3,300
2,666
8,000
8,000
3,300
2,666
400.0
400.0
165.0
133.0
400.0
400.0
165.0
133.0
400.0
400.0
165.0
133.0
86
86
86
87
87
89
88
88
88
90
90
90
External Trim
Fuse Rating
Slow-Blow
(mA)
5,000
5,000
5,000
5,000
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
A simple external circuit may be used to adjust the converter
output. To adjust the output DOWN, connect a 5%, 3W resistor
between the plus output pin and the Vout trim pin. To adjust the
output UP, connect a 5%, 3W resistor between the minus output
pin and the Vout trim pin. To calculate the correct resistor value
(in k) use:
3.3 VOUT UP
RADJ =
(VOUT - 1.24) x (2.87)
VADJ - VOUT
- 10
Other VOUT UP
RADJ =
(VOUT - 2.5) x (2.87)
VADJ - VOUT
- 10
Down RADJ =
(VADJ - 1.24) (VOUT - 1.24) x 2.87
- 10
VOUT - VADJ
Other VOUT Down RADJ =
(VADJ - 2.5) (VOUT - 2.5) x 2.87
- 10
VOUT - VADJ
3.3 VOUT
For UP/Down trimming capability, connect a 10 kW potentiometer
between the plus and minus outputs with the wiper arm connected to the Vout trim pin.
Mechanical Dimensions
Derating Curves
Pin Connections
Pin Single
1
+Vin
2
-Vin
4 ON/OFF
5
-Sense
Pin
6
7
8
9
Single
+Sense
+Vout
-Vout
Trim
Mechanical Notes:
• All dimensions are typical
in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages