TI CDC208DW

CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
D
D
D
D
D
D
D
DW PACKAGE
(TOP VIEW)
Low-Skew Propagation Delay
Specifications for Clock-Driver
Applications
TTL-Compatible Inputs and
CMOS-Compatible Outputs
Flow-Through Architecture Optimizes
PCB Layout
Center-Pin VCC and GND Pin
Configurations Minimize High-Speed
Switching Noise
EPIC  (Enhanced-Performance Implanted
CMOS) 1-µm Process
500-mA Typical Latch-Up Immunity at
125°C
Package Options Include Plastic
Small-Outline (DW)
1Y2
1Y3
1Y4
GND
GND
GND
GND
2Y1
2Y2
2Y3
1
20
2
19
3
18
4
17
5
16
6
15
7
14
8
13
9
12
10
11
1Y1
1A
1OE1
1OE2
VCC
VCC
2A
2OE1
2OE2
2Y4
description
The CDC208 contains dual clock-driver circuits that fanout one input signal to four outputs with minimum skew
for clock distribution (see Figure 2). The device also offers two output-enable (OE1 and OE2) inputs for each
circuit that can force the outputs to be disabled to a high-impedance state or to a high- or low-logic level
independent of the signal on the respective A input.
Skew parameters are specified for a reduced temperature and voltage range common to many applications.
The CDC208 is characterized for operation from – 40°C to 85°C.
FUNCTION TABLES
INPUTS
OUTPUTS
1OE1
1OE2
1A
1Y1
1Y2
1Y3
L
L
L
L
L
L
1Y4
L
L
L
H
H
H
H
H
L
H
X
L
L
L
L
H
L
X
H
H
H
H
H
H
X
Z
Z
Z
Z
INPUTS
OUTPUTS
2OE1
2OE2
2A
2Y1
2Y2
2Y3
2Y4
L
L
L
L
L
L
L
L
L
H
H
H
H
H
L
H
X
L
L
L
L
H
L
X
H
H
H
H
H
H
X
Z
Z
Z
Z
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1998, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
logic symbol†
X/Y
1OE1
18
17
1OE2
1
2
1
1
V4
2
G5
3
EN
4, 5
20
1
1A
19
4, 5
4, 5
4, 5
2OE1
3
13
8
12
9
2OE2
2A
2
10
11
14
1Y1
1Y2
1Y3
1Y4
2Y1
2Y2
2Y3
2Y4
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
1OE1
18
20
1OE2
17
1
2
3
1A
2OE1
19
9
11
2
1Y3
1Y4
2Y1
12
10
2A
1Y2
13
8
2OE2
1Y1
14
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2Y2
2Y3
2Y4
CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 200 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.6 W
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
For more information, refer to the Package Thermal Considerations application note in the 1994 ABT Advanced BiCMOS Technology
Data Book, literature number SCBD002B.
recommended operating conditions
MIN
NOM
MAX
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
IOH
IOL
High-level output current
VCC
– 24
mA
Low-level output current
24
mA
∆t / ∆v
Input transition rise or fall rate
10
ns / V
fclock
TA
Input clock frequency
60
MHz
85
°C
High-level input voltage
2
V
0.8
Input voltage
0
0
Operating free-air temperature
– 40
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
V
V
V
3
CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
4.5 V
IOH = – 50 µA
VOH
IOH = – 24 mA
IOH = – 75 mA†
II
IOZ
ICC
TA = 25°C
TYP
MAX
IOL = 75 mA†
VI = VCC or GND
MIN
4.4
4.4
5.5 V
5.4
5.4
4.5 V
3.94
3.8
5.5 V
4.94
∆ICC‡
One input at 3.4 V,
Other inputs at VCC or GND
Ci
VI = VCC or GND
VO = VCC or GND
0.1
0.1
0.1
0.1
4.5 V
0.36
0.44
5.5 V
0.36
0.44
V
1.65
5.5 V
± 0.1
±1
µA
5.5 V
± 0.5
±5
µA
5.5 V
8
80
µA
5.5 V
0.9
1
mA
5V
POST OFFICE BOX 655303
V
5.5 V
4
Co
5V
10
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
4
UNIT
4.8
5.5 V
IO = 0
MAX
3.85
4.5 V
IOL = 24 mA
VO = VCC or GND
VI = VCC or GND,
MIN
5.5 V
IOL = 50 µA
VOL
VCC
• DALLAS, TEXAS 75265
pF
pF
CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
1A and 2A
Any Y
tPLH
tPHL
1OE1,, 1OE2,, and
2OE1, 2OE2
Any Y
tPZH
tPZL
1OE2 or 2OE2
tPHZ
tPLZ
1OE2 or 2OE2
MIN
Any Y
1OE1 or 2OE1
Any Y
1OE1 or 2OE1
TA = 25°C
TYP
MAX
MIN
MAX
5.3
8.5
10.9
5.3
11.7
3.6
7.7
11
3.6
11.5
4.7
8.5
11.7
4.7
12.8
4.4
8.4
11.3
4.4
12.4
4.4
8.1
11.3
4.4
12.4
5
9.6
13.3
5
14.9
4.2
7.4
9.3
4.2
10.2
5.4
7.5
9.2
5.4
9.9
UNIT
ns
ns
ns
ns
switching characteristics, VCC = 5 V ± 0.25 V, TA = 25°C to 70°C (see Note 3 and Figures 1 and 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
1A and 2A
Any Y
MIN
MAX
6.6
10.2
6.6
9.8
tsk(o)
1A and 2A
Any Y
NOTE 3: All specifications are valid only for all outputs switching simultaneously and in phase.
1
UNIT
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
d
Power dissipation capacitance per bank
TEST CONDITIONS
Outputs enabled
Outputs disabled
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CL = 50 pF,
pF
f = 1 MHz
TYP
96
12
UNIT
pF
5
CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
PARAMETER MEASUREMENT INFORMATION
2 × VCC
From Output
Under Test
500 Ω
3V
Output
Control
(low-level
enabling)
LOAD CIRCUIT FOR OUTPUTS
1.5 V
3V
1.5 V
1.5 V
0V
tPLH
Output
tPHL
VOH
50% VCC
VOL
50% VCC
tPLZ
≈ VCC
Output
Waveform 1
S1 at 2 × VCC
(see Note C)
Output
Waveform 2
S1 at 2 × VCC
(see Note C)
1.5 V
0V
tPZL
Input
(see Note B)
S1
Open
2 × VCC
GND
TEST
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
Open
GND
CL = 50 pF
(see Note A)
(see Note A)
S1
500 Ω
50% VCC
tPZH
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
20% VCC
VOL
tPHZ
50% VCC
80% VCC
VOH
0V
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 3 ns, tf ≤ 3 ns.
For testing pulse duration: tr = tf = 1 to 3 ns. Pulse polarity can be either high-to-low-to-high or low-to-high-to-low.
C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
Figure 1. Load Circuit and Voltage Waveforms
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
PARAMETER MEASUREMENT INFORMATION
1A, 2A
1Y1
tPLH1
tPHL1
tPLH2
tPHL2
tPLH3
tPHL3
tPLH4
tPHL4
tPLH5
tPHL5
tPLH6
tPHL6
tPLH7
tPHL7
tPLH8
tPHL8
1Y2
1Y3
1Y4
2Y1
2Y2
2Y3
2Y4
NOTE A: Output skew, tsk(o), is calculated as the greater of:
– The difference between the fastest and slowest of tPLHn (n = 1, 2, . . . , 8)
– The difference between the fastest and slowest of tPHLn (n = 1, 2, . . . , 8)
Figure 2. Waveforms for Calculation of tsk(o)
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
CDC208
DUAL 1-LINE TO 4-LINE CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS109F – APRIL 1990 – REVISED OCTOBER 1998
MECHANICAL INFORMATION
DW (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
16 PIN SHOWN
0.050 (1,27)
0.020 (0,51)
0.014 (0,35)
16
0.010 (0,25) M
9
0.419 (10,65)
0.400 (10,15)
0.010 (0,25) NOM
0.299 (7,59)
0.293 (7,45)
Gage Plane
0.010 (0,25)
1
8
0°– 8°
A
0.050 (1,27)
0.016 (0,40)
Seating Plane
0.104 (2,65) MAX
0.012 (0,30)
0.004 (0,10)
0.004 (0,10)
PINS **
16
20
24
A MAX
0.410
(10,41)
0.510
(12,95)
0.610
(15,49)
A MIN
0.400
(10,16)
0.500
(12,70)
0.600
(15,24)
DIM
4040000 / D 02/98
NOTES: A.
B.
C.
D.
8
All linear dimensions are in inches (millimeters).
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0.006 (0,15).
Falls within JEDEC MS-013
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
17-Nov-2005
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
CDC208DBLE
OBSOLETE
SSOP
DB
20
TBD
Call TI
CDC208DW
ACTIVE
SOIC
DW
20
25
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDC208DWG4
ACTIVE
SOIC
DW
20
25
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDC208DWR
ACTIVE
SOIC
DW
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDC208DWRG4
ACTIVE
SOIC
DW
20
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDC208N
OBSOLETE
PDIP
N
20
Package
Drawing
Pins Package Eco Plan (2)
Qty
TBD
Lead/Ball Finish
Call TI
MSL Peak Temp (3)
Call TI
Call TI
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address:
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2005, Texas Instruments Incorporated