Wabash CL40V41-000 Class 2 ul5085-3 transformer 40va, core 3/4', inherently energy limited Datasheet

Class 2 UL5085 - 3 Transformer
40VA, Core 3/4”, Inherently Energy Limited
Series: CL - Lead Wires & Quick-Connects

Power Rating 40VA

No Secondary Fusing Required

Frequency 50/60Hz

Insulation Class F (155°C)
Agency Approvals:

UL/cUL 5085-3 Class 2 Recognized (File E49606)

Insulation File No. E95662
* Multi voltage combinations are available - consult factory.
Class 2
Lead Wires
Quick-Connects
Type HX Foot Mount - Steel bracket welded to the
bottom of the laminations for easy mounting
Type GX Panel Mount - 0.179” (4.55 mm) diameter
holes in each corner to allow direct mounting to a panel.
Lead Wires: All leads are 18 AWG stranded 2/64” (0.794 mm)
insulation thickness. Standard parts have 12” (305 mm)
total length with 1/2” (12.7 mm) strip.
Type BB Foot Mount, Pri & Sec on Same Side - Quick connect terminals
with line and load terminations on the same side of transformer.
Type AE Laydown, Pri & Sec on Top Side - Quick connect terminals
with line and load terminations on the top of transformer.
Type AB Foot Mount Pri & Sec on Opposite Side - Quick connect terminals
with line and load terminations on opposite sides of transformer
Terminals:
Standard male quick connects - 0.250” x 0.032” (6.35 x 0.81 mm)
Other available quick connects - 0.187” x 0.032” (4.75 x 0.81 mm)
Type BB - Foot Mount, Pri & Sec on Same Side
Type HX - Foot Mount
Type AE - Laydown, Pri & Sec on Top Side
Type GX - Panel Mount
Type AB - Foot Mount, Pri & Sec on Opposite Side
Dimensions (Inches)
A
B
Weight (Lbs)
40VA - V
2.410
1.250
0.710
Any application, Any requirement, Contact us for our Custom Designs
12
Sales Office:
300 W Factory Road, Addison IL 60101 • Phone: (630) 628-9999 • Fax: (630) 628-9922
• www.wabashtransformer.com
Class 2 UL5085 - 3 Transformer
40VA, Core 3/4”, Inherently Energy Limited
Class 2
Series: CL - Lead Wires & Quick-Connects
Partial Selection Guide
Primary
Voltage
Secondary
Voltage
40 VA
Size - 3/4” X 1-1/4”
UL
Primary
Voltage
Secondary
Voltage
40 VA
Size - 3/4” X 1-1/4”
UL
208/230
24
CL40V00-000*
-
120/277
24
CL40V41-000*
-
120
24
CL40V01-000*
-
208/277/480
24
CL40V42-000*
-
277
24
CL40V02-000*
-
277/380/415
24
CL40V43-000*
-
120/208/240
24
CL40V03-000*
-
208/240/480
24
CL40V44-000*
-
480
24
CL40V04-000*
-
208
24
CL40V45-000*
-
600
24
CL40V06-000*
-
220/240
24
CL40V47-000*
-
120/240
24
CL40V07-000*
-
100
24
CL40V48-000*
√
380
24
CL40V09-000*
-
220
24
CL40V49-000*
-
240
24
CL40V40-000*
-
24
CL40V51-000*
√
24
CL40V52-000*
-
115
24
CL40V15-000*
-
25
CL40V61-000*
-
346
24
CL40V53-000*
-
415
24
CL40V16-000*
-
208/230/460
24
CL40V54-000*
-
380/415
24
CL40V17-000*
-
400
24
CL40V55-000*
-
575
24
CL40V21-000*
-
575/600
24
CL40V56-000*
-
208/240/277
24
CL40V23-000*
-
200/230/460
24
CL40V58-000*
-
240/480
24
CL40V24-000*
-
230/460
24
CL40V59-000*
-
380/415/575
24
CL40V27-000*
-
380/460
24
CL40V60-000*
-
460
24
CL40V28-000*
-
115/230
24
CL40V62-000*
-
480/575
24
CL40V30-000*
-
230
24
CL40V63-000*
-
120/208/240/277
24
CL40V36-000*
-
240/277/480
24
CL40V64-000*
-
208/240
* Refer to page number 7. Must complete part number to specify voltages, termination, mounting & fusing.
For custom designs 3 digit customer ID will be added at the end of the part number.
Lead Wire Details:
Primary Voltage
Color
Secondary Voltage
Color
COM
Black
COM
Blue
110,115,120
White
12
Yellow
200,208,215
Red
24
Blue
220, 230, 240
Orange
265, 277
Brown
380
Violet
400, 415
Red/White
460, 480
Grey
575
Black/Red
600
Black/White
Standard leads: All leads are 12.0” L.O.C (length out of coil) 1/2” strip
Any application, Any requirement, Contact us for our Custom Designs
Sales Office:
300 W Factory Road, Addison IL 60101 • Phone: (630) 628-9999 • Fax: (630) 628-9922
• www.wabashtransformer.com
13
Similar pages