ETC COM5233T

COM5201T COM5203T COM5217T COM5234T
COM5202T COM5216T COM5233T
(COTS) COMMERCIAL OFF-THE-SHELF, HIGH
EFFICIENCY, CENTER-TAP RECTIFIERS, TO-257
16 Amp, 50 To 600 Volts, 35 To 60 ns trr
FEATURES
•
•
•
•
•
•
•
Very Low Forward Voltage
Very Fast Recovery Time
Hermetic Metal Package, JEDEC TO-257AA Outline
Low Thermal Resistance
Isolated Package
High Surge
Standard Off-The-Shelf
DESCRIPTION
This series of products in a hermetic package is specifically designed for use at power
switching frequencies in excess of 100 kHz. The series combines two high efficiency
devices into one package, simplifying installation, reducing heat sink hardware, and
the need to obtain matched components. These devices are ideally suited for Hi-Rel
applications where small size and a hermetically sealed package is required.
Common
cathode is standard.
ABSOLUTE MAXIMUM RATINGS
(Per Diode) @ 25°C
Peak Inverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 to 600
V Maximum Average D.C. Output Current @ TC = 100° C . . . . . . . . . . . . . . . . . . . .
8A Surge Current (Non-Repetitive 8.3 msec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
60A Operating and Storage Temperature Range. . . . . . . . . . . . . . . . . . . - 55° C to +
150° C X.
MECHANICAL OUTLINE
S C H E M ATIC
1
2
3
COMMON
CATHODE
.200
.190
.420
.410
.045
.035
.665
.645
.150
.140
.537
.527
1
2
.430
.410
3
.038 MAX.
.750
.500
Common cathode is standard.
Standard products are supplied with glass feedthroughs.
98 09 R0
3.2 - 1
.035
.025
.100 TYP.
.005
.120 TYP.
3.2
COM5201T - COM5234T
ELECTRICAL CHARACTERISTICS (Per Diode)
Maximum
Forward Voltage
(Volts) @ (1)
Tj= 25° C
Tj= 100° C
Type
PIV
COM5201T
COM5202T
COM5203T
COM5216T
COM5217T
COM5233T
COM5234T
50
100
150
200
300
400
600
Maximum
Reverse Current
@ PIV
Tj= 25° C Tj= 100° C
Maximum Maximum
Reverse
Thermal
Recovery
Resist.
Time (2)
R qJC
1.3V @ 8A
.975V @ 8A
10 µA
500 µA
35 nsec
2.5
1.55V @ 8A
1.25V @ 8A
20 µA
1.0 mA
60 nsec
2.5
(1) Pulse Test: Pulse Width = 300µs, Duty Cycle
2.0%. (2) Measured in Circuit: IF = 0.5 A, IR = 1.0 A, IR E C = 0.25 A
50 V TO 200 V
TYPICAL FORW ARD VOLTA G E
COM5201, 5202, 5203, 5216
300 V TO 600 V
TYPICAL FORW ARD VOLTA G E
COM5217, 5233, 5234
100
100
TJ = 150°C
100°C
50
IF = INSTANTANEOUS FORWARD CURRENT (AMPS)
IF = INSTANTANEOUS FORWARD CURRENT (AMPS)
50
25°C
30
20
100°C
10
5.0
3.0
2.0
1.0
0.5
0.3
0.2
30
20
TJ = 150°C
10
25°C
5.0
3.0
2.0
1.0
0.5
0.3
0.2
3.2
0.1
0.1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
V F = INSTANTANEOUS VOLTAGE (VOLTS)
TYPICAL REVERSE CURRENT
COM5201, 5202, 5203, 5216
TYPICAL REVERSE CURRENT
COM5217, 5233, 5234
100
50
20
10
5.0
100
50
20
10
5.0
TJ = 150°C
100°C
2.0
1.0
0.5
25°C
0.2
0.1
0.05
0.02
0.01
IR = REVERSE CURRENT (µA)
IR = REVERSE CURRENT (µA)
V F = INSTANTANEOUS VOLTAGE (VOLTS)
TJ = 150°C
2.0
1.0
0.5
100°C
0.2
0.1
0.05
25°C
0.02
0.01
0
20
40
60
80
100 120 140 160 180 200
V R = REVERSE VOLTAGE (VOLTS)
0
50
100
150 200 250 300 350 400 450 500
V R = REVERSE VOLTAGE (VOLTS)
205 Crawford Street, Leominster, MA 01453 USA (978) 534-5776 FAX (978) 537-4246