ETC2 CPCIS-6235R 2u rackmount chassis with dual ac-input Datasheet

cPCIS-6235R Series
2U Rackmount Chassis with Dual AC-Input
Mini Redundant Power Supplies
Features
6U cPCI Platforms
19” Rackmount, 2U height for 6U cPCI boards
with 80 mm rear I/O
Standard 6U CompactPCI® and PICMG® 2.5
H.110 CT Bus
PICMG® 2.1 Hot Swap compliant 32/64-bit 3-slot
CompactPCI® backplane with P3 & P5 rear I/O
Built-in 300 W + 300 W Dual AC-input
mini redundant power supply units
LED indicators for power status, fan status,
temperature alarm
Specifications
Recommended Configurations
Enclosure
CPU Board
(System slot)
EIA RS-310C 19” 2U high Rackmount enclosure
Coated metal plate outer covering
Guarded power switch and alarm reset button
CompactPCI® Standards 2.0 R3.0, 2.1 R2.0, 2.5 R1.0
Form Factor
6U CompactPCI® with 80 mm depth rear I/O
Backplane
cBP-6103R: 3-slot 32-bit 6U cPCI CT bus backplane
cBP-6403R: 3-slot 64-bit 6U cPCI CT bus backplane
cBP-6403R/N110: 3-slot 64-bit 6U cPCI without CT bus
backplane
Power Supply
300 W +300 W dual AC-input mini redundant power supplies
with cooling fan
Active PFC (full range), meets IEC-1000-3-2 CLASS D
Dual-AC inlet with EMI noise filter: FCC Class B, CISPR22
Class B
Cooling
Two 40 mm DC fans per module
AC Input
Full Range, 100~220 VAC (±10%)
Frequency Range: 47-63 Hz
DC Output
32 A @ +5 V, 20 A @ +3.3 V, 16 A @ +12 V,
0.8 A @ -12 V, 0.5 A @ -5 V, 1.5 A @ +5 Vsb
Maximum Total Output for +5 V and +3.3 V: 35 A
Maximum Total Output for +5 V, +3.3 V and
+12 V: 285 W
Efficiency: 63% at 115 V, full load
Temperature Operating 0˚C to 40˚C, Storage -20˚C to 80˚C
Range
Certifications UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
Dimensions 220 x 120 x 85 (mm, H x W x D)
LED Indicators
Six LEDs indicate power voltage status on +3.3 V, +5 V,
+12 V and -12 V, fan status and temperature alarm
Cooling System
Front access hot swappable fan tray with three fan modules
for exhaust
• Fan type: 12 V DC brushless
• Rated speed: 4000 RPM
• Rated current: 0.22 A (Max 0.33 A)
• Max air flow: 48.2 CFM
• Acoustical noise: 41 dBA
• MTBF: 70,000hrs
• Three LEDs indicate fan status
Dimensions
484.1 x 88.1 x 358.8 (mm, W x H x D, w/ handle)
Weight
17.1 kg/38 lbs
Operating Temp.
0˚C to 40˚C
Storage Temp.
-20˚C to 80˚C
Humidity
5% to 95%, non-condensing
Shock
15 G peak to peak, 11 ms duration, non-operation
Vibration
Non-operation: 1.88 Grms, 5-500 Hz,each axis
Operation: 0.50Grms, 5-500Hz, each axis, tested with
2.5” HDD
Rear I/O Board
cPCIS-6235R
cPCI-6615, cPCI-6615D
cPCI-R6002
cPCIS-6235R/64
cPCI-6510, cPCI-6510V
cPCI-R6002(D), cPCI-R6100, cPCI-R6110,
cPCI-R6210, cPCI-R6200, cPCI-R6700(D)
cPCI-6880, cPCI-6880P
cPCI-R6000P, cPCI-R6002(D), cPCI-R6100,
cPCI-R6110, cPCI-R6200, cPCI-R6700
cPCI-6870
cPCI-R6101, cPCI-R6111
cPCI-6210, cPCI-6210D
cPCI-R6002(D), cPCI-R6100, cPCI-R6110,
cPCI-R6200, cPCI-R6700D
Ordering Information
Model Number
cPCI Bus
PSU Type
CMM
PSU MAX
ACINPUT
H.110
Alarm
Board
cPCIS-6235R
32-bit/33MHz
ATX
--
300W
2
Y
Basic
Alarm
Module
cPCIS-6235R/64
64-bit/66MHz
ATX
--
300W
2
Y
Basic
Alarm
Module
cPCIS-6235R/64/N110
64-bit/66MHz
ATX
--
300W
2
N
Basic
Alarm
Module
Mechanical Layout
Rear View
Top-side
System Slot
Thermal Sensor
Two Peripheral Slots
Hot Swappable Fan Tray
Module with LEDs
3-17
http://www.adlinktech.com/cPCI/
Alarm Module
Guarded Power Switch and Alarm
Reset Button
Voltages and
Alarm LEDs