ETC 13A-015G

Model 13 Medium Pressure
Medical Instrumentation
PC Board Mountable Pressure Sensor
HVAC
0-100 mV Output
Barometric Pressure
Gage and Absolute Pressure
Process Control
Temperature Compensated
Vacuum Measurement
Air Flow Management
DESCRIPTION
The Model 13 is a temperature compensated, piezoresistive
silicon pressure sensor packaged in TO-8 configurations. It
provides excellent performance and long-term stability.
Gage and absolute pressure ranges from 0-2 PSI to 0-250
PSI are available. Integral temperature compensation is
provided over a range of 0-50°C using laser-trimmed resistors.
An additional laser-trimmed resistor is included to normalize
pressure sensitivity variations by programming the gain of an
external differential amplifier. This provides sensitivity
interchangeability of ±1%.
Please refer to the low pressure section for information on
products with operating pressures less than 0-2 PSI. For an
uncompensated sensor (Model 10) please contact the factory for
additional information.
FEATURES
DIMENSIONS
TO-8 Package
±0.1% Non-linearity
±0.5% Temperature Performance
Solid State Reliability
Low Power
STANDARD RANGES
1-30
Range
psig
psia
0 to 2
●
0 to 5
●
●
0 to 10
●
●
0 to 15
●
●
0 to 30
●
●
0 to 50
●
●
0 to 100
●
●
0 to 250
●
●
TO-8 – Standard
Model 13 Medium Pressure
PC Board Mountable Pressure Sensor
PERFORMANCE SPECIFICATIONS
Supply Current: 1.5mA
Ambient Temperature: 25°C (Unless otherwise specified)
PARAMETERS
MIN
TYP
MAX
UNITS
Full Scale Output Span
75
100
150
mV
Full Scale Output Span (2 psi version)
30
Zero Pressure Output
60
mV
2
±mV
Pressure Non-linearity
0.05
0.10
±% Span
Pressure Hysteresis
0.01
0.05
±% Span
NOTES
1
4400
6000
Ω
Temperature Error – Span
0.3
0.5
±% Span
2
Temperature Error – Zero
0.1
0.5
±% Span
1, 2
Thermal Hysteresis – Span
0.1
±% Span
2
Thermal Hysteresis – Zero
0.1
±% Span
2
Supply Current
1.5
mA
3
Input & Output Resistance
2500
2.0
Response Time
1.0
msec
4
Output Noise
1.0
µV p-p
5
2
MΩ
6
50
MΩ
7
Rated
8
Output Load Resistance
Insulation Resistance (50 VDC)
Pressure Overload
3X
Operating Temperature
–40°C to +125°C
Storage Temperature
–50°C to +150°C
Acceleration
50g Max
Shock
1000g Peak for 0.5mS
Vibration
20g Peak at 10 to 2000 Hz
Media
Non-Corrosive Gases
Weight
3 Grams
Notes
1. Best Fit Straight Line. For 2 psi output span is 30-60 mV and TC zero
temperature error is ±1.25%.
2. Temperature range 0-50°C in reference to 25°C.
3. Guarantees input/output ratiometricity.
4. For a zero-to-full scale pressure step change.
5. 10 Hz to 1 kHz.
CONNECTIONS
9
6.
7.
8.
9.
Prevents increase of TC Span due to output loading.
Between case and sensing element.
3X not to exceed 500 psi on ranges: 0-10 psi to 0-250 psi; 20 psi for 2
psi and 5 psi versions.
For Top Entry versions, wetted materials are silicon, aluminum, gold,
RTV, glass, and nickel. For Bottom Entry versions, wetted materials are
silicon, RTV, gold, and glass.
ORDERING INFORMATION
APPLICATION SCHEMATIC
June 2001
TO-8 – Standard
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
1-31