CUI CT-1205CL

rev.
PART NUMBER: CT-1205CL
A
page
1 of 5
date
02/2008
DESCRIPTION: magnetic buzzer
SPECIFICATIONS
rated voltage
operating voltage
current consumption
sound output
rated frequency
operating temperature
storage temperature
dimensions
weight
material
terminal
RoHS
5 V dc
4 ~ 7 V dc
30 mA max.
88 dBA min. (92 typ.)
at a distance of 10 cm (A-weight free air) and 5 V dc
2400 Hz ±400 Hz
-30 ~ +70° C
-40 ~ +85° C
L12.8 x W12.8 x H7.1 mm
2.0 g max.
PPS
SMD type (Sn Plating)
yes
APPEARANCE DRAWING
tolerance: ±0.5
3x
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
rev.
PART NUMBER: CT-1205CL
DESCRIPTION: magnetic buzzer
VOLTAGE: SOUND PRESSURE LEVEL / CURRENT CONSUMPTION
MEASUREMENT METHOD
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
A
page
2 of 5
date
02/2008
rev.
A
page
3 of 5
date
02/2008
DESCRIPTION: magnetic buzzer
PART NUMBER: CT-1205CL
MECHANICAL CHARACTERISTICS
item
solderability
soldering heat resistance
terminal mechanical strength
vibration
drop test
test condition
Lead terminals are immersed in solder bath
of 270 ±5°C for 3 ±1 seconds.
The product should follow the reflow
temperature curve to test its reflow thermo
stability.
For 10 seconds, the force of 9.8N (1.0kg) is
applied to each terminal in axial direction.
The buzzer will be measured after applying
a vibration amplitude of 1.5 mm with 10 to
55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The part will be dropped from a height of
75 cm onto a 40 mm thick wooden board 3
times in 3 axes (X, Y, Z) for a total of 9 drops.
evaluation standard
95% of the surface of the lead
pads will be wet with solder.
test condition
After being placed in a chamber at +85°C for
96 hours.
After being placed in a chamber at -40°C for
96 hours.
The part shall be subjected to 10 cycles. One
cycle will consist of:
evaluation standard
No interference in operation.
No damage or cutting off.
After the test, the part will meet
specifications without any
damage in appearance and the
SPL should be within ±10% of the
i initial measurements.
ENVIRONMENT TEST
item
high temp. test
low temp. test
thermal shock
temp. cycle test
The part shall be subjected to 10 cycles. One
cycle will last 24 hours and will consist of:
After the test, the part will meet
specifications without any
damage in appearance except
SPL. After 4 hours at 25°C, SPL
should be within ±10% of the
initial measurements.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
rev.
A
page
4 of 5
date
02/2008
DESCRIPTION: magnetic buzzer
PART NUMBER: CT-1205CL
RELIABILITY TEST
item
operating (life test)
test condition
1. Continuous life test:
The part will be subjected to 72 hours of
continuous operation at +55°C with
5 V applied.
evaluation standard
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 10,000 times at room temp
(+25 ±10°C) with 5 V dc applied.
After the test, the part will meet
specifications without any
damage in appearance except
SPL. After 4 hours at 25°C, SPL
should be within ±10% of the
initial measurements.
TEST CONDITIONS
standard test condition
judgement test condition
a) temperature: +5 ~ +35°C
a) temperature: +25 ±2°C
b) humidity: 45 - 85%
b) humidity: 60 - 70%
c) pressure: 860-1060 mbar
c) pressure: 860-1060 mbar
RECOMMENDED TEMPERATURE PROFILE FOR REFLOW OVEN
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
rev.
PART NUMBER: CT-1205CL
DESCRIPTION: magnetic buzzer
RECOMMENDED LAND PATTERN
PACKAGING
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383
A
page
5 of 5
date
02/2008