D100E Series Low Cost, 1W SIP Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: Parameter Conditions Min. Typ. Max. 5 VDC Input 4.5 5.0 5.5 12 VDC Input 10.8 12.0 13.2 24 VDC Input 21.6 24.0 26.4 • 1W Output Power • Miniature SIP Case • UL Approved (File E245422) • Single & Dual Outputs • 1,000 VDC Isolation Input Voltage Range Input Filter VDC Internal Capacitor Reverse Polarity Input Current 0.3 A Units Output • >3.5 MHour MTBF Parameter • 24 Standard Models Output Voltage Accuracy • LOWEST COST!! Output Voltage Balance Line Regulation Load Regulation (Note 1) Conditions Min. Typ. Max. ±1.0 ±3.0 % Dual Output , Balanced Loads ±0.1 ±1.0 % For Vin Change of 1% ±1.2 % See Model Selection Guide Ripple & Noise (20 MHz) (Note 2) 50 Output Power Protection 75 mV P - P 120 Temperature Coefficient % ±0.02 Output Short Circuit RoHS Compliant Units ±0.03 %/ºC Max. Units Momentary (1.0 Sec.) General Parameter Conditions Isolation Voltage Isolation Resistance Isolation Capacitance Min. 60 Seconds 1,000 500 VDC 1,000 100 kHz, 1V Switching Frequency Typ. VDC MΩ 60 pF 100 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Storage Temperature Range Typ. Max. -40 +25 +85 ºC +125 ºC 95 % -55 Cooling Humidity Min. Units Free Air Convection RH, Non-condensing Physical MicroPower Direct Case Size 292 Page Street Suite D Stoughton, MA 02072 USA Case Material T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com MTBF 0.77 x 0.24 x 0.40 Inches (19.6 x 6.0 x 10.2 mm) Non-Conductive Black Plastic (UL94-V0) Weight 0.07 Oz (2.1g) Reliability Specifications Parameter Conditions Min. MIL HDBK 217F, 25ºC, Gnd Benign Typ. Max. 3.5 Units MHours Safety Standards UL 1950, EN 60950, IEC 60950 Safety Approvals UL, cUL; File No. E245422 Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions Min. Typ. Max. 5 VDC Input -0.7 9.0 12 VDC Input -0.7 18.0 24 VDC Input -0.7 30.0 Units VDC 1.5 mm From Case For 10 Sec 300 ºC All Models 450 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number D101E D102E D103E D104E D105E D106E D107E D108E D111E D112E D113E D114E D115E D116E D117E D118E D121E D122E D123E D124E D125E D126E D127E D128E Input Output Load Voltage (VDC) Current (mA) Regulation Voltage Current Current Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) 5 4.5 - 5.5 278 30 5.0 200.0 20.0 15 5 4.5 - 5.5 270 30 9.0 111.0 12.0 15 5 4.5 - 5.5 260 30 12.0 83.0 9.0 15 5 4.5 - 5.5 253 30 15.0 67.0 7.0 15 5 4.5 - 5.5 278 30 ±5.0 ±100.0 ±10.0 15 5 4.5 - 5.5 267 30 ±9.0 ±56.0 ±6.0 15 5 4.5 - 5.5 256 30 ±12.0 ±42.0 ±5.0 15 5 4.5 - 5.5 253 30 ±15.0 ±33.0 ±4.0 15 12 10.8 - 13.2 114 15 5.0 200.0 20.0 15 12 10.8 - 13.2 111 15 9.0 111.0 12.0 15 12 10.8 - 13.2 105 15 12.0 83.0 9.0 15 12 10.8 - 13.2 104 15 15.0 67.0 7.0 15 12 10.8 - 13.2 113 15 ±5.0 ±100.0 ±10.0 15 12 10.8 - 13.2 110 15 ±9.0 ±56.0 ±6.0 15 12 10.8 - 13.2 105 15 ±12.0 ±42.0 ±5.0 15 12 10.8 - 13.2 104 15 ±15.0 ±33.0 ±4.0 15 24 21.6 - 26.4 56 8 5.0 200.0 20.0 15 24 21.6 - 26.4 55 8 9.0 111.0 12.0 15 24 21.6 - 26.4 52 8 12.0 83.0 9.0 15 24 21.6 - 26.4 51 8 15.0 67.0 7.0 15 24 21.6 - 26.4 56 8 ±5.0 ±100.0 ±10.0 15 24 21.6 - 26.4 55 8 ±9.0 ±56.0 ±6.0 15 24 21.6 - 26.4 52 8 ±12.0 ±42.0 ±5.0 15 24 21.6 - 26.4 51 8 ±15.0 ±33.0 ±4.0 15 Efficiency (%, Typ) 72 74 77 79 72 75 78 79 73 75 79 80 74 76 79 80 74 76 80 81 74 76 80 81 Fuse Rating Slow-Blow (mA) 500 500 500 500 500 500 500 500 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 Derating Curve Other input/output combinations are available (i.e. 3.3 VDC). Contact the factory for details at: [email protected] Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 3. These converters will operate without external components. However, when measuring output ripple, it is recommended that an external ceramic capacitor Output Capacitor Input be placed from the Vin Vout Capacitor Single Dual +Vout pin to the -Vout pin for single 5 VDC 4.7 μF 5 VDC 10.0 μF 4.7 μF output units and 12 VDC 2.2 μF 9 VDC 4.7 μF 2.2 μF from each output 24 VDC 1.0 μF 12 VDC 2.2 μF 1.0 μF to common for dual 15 VDC 1.0 μF 0.47 μF output units. An in- Mechanical Dimensions put capacitor will enhance stability over temperature and input line variations. Recommended capacitor values are given in the table above. For applications requiring very low output noise levels, a simple LC filter should be effective. 4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Single Dual Pin Single Dual 1 2 4 +Vin -Vin -Vout +Vin -Vin -Vout 5 6 No Pin +Vout Common +Vout Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the side of the unit MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]