MPD D205RU Miniature sip, 2w ultra-wide 4:1 input dc/dc converter Datasheet

D200RU Series
Miniature SIP, 2W
Ultra-Wide 4:1 Input
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• 4:1 Input Voltage Range
• 1,000 VDC Isolation
• Short Circuit Protected
• Miniature SIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
RoHS Compliant
Input
Parameter
Input Start Voltage
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Conditions
Min.
24 VDC Input
4.5
48 VDC Input
8.5
Capacitor Filter
Typ.
6.0
12.0
Max.
8.5
17.0
Units
0.5
1,500
A
mW
Typ.
±1.0
±1.0
±0.3
±0.5
30
Max.
±2.0
±2.0
±0.5
±0.75
50
75
15
100
±3.0
±0.01
300
±5.0
±0.02
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
μSec
%
%/°C
Typ.
Max.
250
300
500
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Response Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Vin = Min to Max
Iout = 25% to 100%
Over Line, Load & Temp.
120
25% Load Step Change
Continuous
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
Flash Tested For 1 Sec
500 VDC
100 kHz, 1V
Min.
1,000
1,100
1,000
Units
VDC
VDC
MΩ
pF
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-40
+25
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Case
Max.
+65
+65
+105
Units
°C
°C
°C
95
%
Physical
Case Size
Case Material
Weight
1.02 x 0.36 x 0.49 Inches (25.95 x 9.25 x 12.45 mm)
Non-Conductive Black Plastic (UL94-V0)
0.23 Oz (6.5g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1,000
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260
2,500
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
VDC
°C
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D201RU
D202RU
D203RU
D204RU
D205RU
D206RU
D207RU
D211RU
D212RU
D213RU
D214RU
D215RU
D216RU
D217RU
Input
Output
Reflected
Efficiency
Voltage (VDC)
Current (mA)
Ripple
Voltage Current
Current
(%, Typ)
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min) Current (mA)
24
9.0 - 36.0
97
20
3.3
500.0
125.0
300
71
24
9.0 - 36.0
110
20
5.0
400.0
100.0
300
76
24
9.0 - 36.0
106
20
12.0
167.0
42.0
300
79
24
9.0 - 36.0
105
20
15.0
134.0
33.0
300
80
24
9.0 - 36.0
114
20
±5.0
±200.0
±50.0
300
73
24
9.0 - 36.0
108
20
±12.0
±83.0
±21.0
300
77
24
9.0 - 36.0
106
20
±15.0
±67.0
±17.0
300
79
48
18.0 - 75.0
49
15
3.3
500.0
125.0
600
70
48
18.0 - 75.0
58
15
5.0
400.0
100.0
600
72
48
18.0 - 75.0
54
15
12.0
167.0
42.0
600
78
48
18.0 - 75.0
54
15
15.0
134.0
33.0
600
78
48
18.0 - 75.0
60
15
±5.0
±200.0
±50.0
600
70
48
18.0 - 75.0
55
15
±12.0
±83.0
±21.0
600
76
48
18.0 - 75.0
55
15
±15.0
±67.0
±17.0
600
76
Notes:
1. When measuring output ripple, it is recommended that an external
0.47 μF ceramic capacitor be placed from the +Vout pin to the
-Vout pin for single output units and from each output to common
for dual output units. For noise sensitive applications, the use of
3.3 μF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a
load step change of 75% to 100%.
3. Operation at no-load will not damage these units. However, they
may not meet all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC,
or 30 VDC output. To do this, connect the load across the positive
(+Vout) and negative (-Vout) outputs and float the output common.
5. The converter should be connected to a low ac-impedance source.
An input source with a highly inductive impedance may affect
the stability of the converter. In applications where the converter
output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure startup.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100
kHz) capacitor be mounted close to the converter. For all models,
it is recommended a 1.5 μF be used.
6. The optional remote
Min
Max
on/off control pin
On
<0.6 VDC to Open Circuit
is referenced to
the
-Vin pin.
Off
2.7 VDC
15.0 VDC
The standby input
-1 mA
current is typically In. Current (on)
1 mA
0 . 1 m A ( 0 . 2 m a In. Current (off)
maximum).
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Capacitive Load
Output (VDC)
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
μF Max
2,200
1,000
170
110
470
100
47
Note: For dual output
units, Cap load is given for
each output.
Fuse Rating
Slow-Blow
(mA)
350
350
350
350
350
350
350
135
135
135
135
135
135
135
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
2
3
6
7
8
9
Single
Dual
-Vin
-Vin
+Vin
+Vin
Remote ON/OFF
+Vout
+Vout
NC
Common
NC
NC
-Vout
-Vout
NF = No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages