HDO4000 High Definition Oscilloscopes 200 MHz – 1 GHz Key Features Combining Teledyne LeCroy’s HD4096 high definition 12-bit • technology, with long memory, a compact form factor, 12.1” touch 12-bit ADC resolution, up to 15-bit with enhanced resolution • 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths • • • • • • ideal oscilloscope for precise measurements and quick debug. Tools such as WaveScan Search and Find, LabNotebook Report Generator, and History Mode help identify and isolate problems L ong Memory – up to 50 Mpts for faster troubleshooting. 12.1” touch screen display HD4096 Technology Large 12.1” Touch Screen HD4096 high definition technology Navigating complicated user interfaces consists of high sample rate 12-bit is a thing of the past thanks to the ADCs, high signal-to-noise input large touch screen display of the and Find amplifiers and a low-noise system HDO4000. The user interface was LabNotebook Documentation architecture. This technology enables designed for touch screens which Multi-language User Interface WaveScan – Advanced Search high definition oscilloscopes to capture makes navigating the HDO4000 and Report Generation and display signals of up to 1 GHz with extremely intuitive. Every aspect of the History Mode – Waveform high sample rate and 16 times more interface is touchable making channel, resolution than other oscilloscopes. timebase and trigger settings only Playback • • • screen display and powerful debug tools, the HDO4000 is the Spectrum Analyzer Mode Power Analysis Software Serial Data Trigger and Decode Long Memory one touch away. With up to 50 Mpts of memory Compact Form Factor the HDO4000 High Definition The HDO4000 builds upon Teledyne Oscilloscopes can capture large LeCroy’s history of “Large Screen, amounts of data with more precision Small Footprint” with its 12.1” wide than other oscilloscopes. The 2.5 GS/s, touch screen display and 5” depth. 50 Mpts architecture provides the Additionally, the innovative rotating, ability to capture a fast transient or a tilting feet enable the HDO4000 to be long acquisition. placed in 4 different viewing positions ensuring optimal viewing no matter where it is being positioned in the lab. HD4096 High Definition Technology High Signal to Noise Input Amplifiers High Sample Rate 12-bit ADC’s Low Noise System Architecture HD4096 high definition technology consists of high sample rate 12-bit ADCs, high signal-to-noise ratio amplifiers and a low-noise system architecture. This technology enables high definition oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes. Oscilloscopes with HD4096 technology have higher resolution and measurement precision than 8-bit alternatives. The high sample rate 12-bit ADCs provide high resolution sampling at up to 2.5 GS/s. The high performance input amplifiers deliver phenomenal signal fidelity with a 55 dB signal-to-noise ratio and provide a pristine signal to the ADC to be digitized. The low-noise signal architecture ensures that nothing interferes with the captured signal and the oscilloscope displays a waveform that accurately represents the signals from the device under test. 16x Closer to Perfect 8-bit 12-bit Digitized Waveform Quantization Error 16x More Resolution 12-bits of vertical resolution provides sixteen times more resolution than 8-bits. The 4096 discrete levels reduce the quantization error. Signals captured with lower resolution oscilloscopes have a higher level of quantization error resulting in less accurate waveforms on the display. Signals captured on an oscilloscope with 12-bit HD4096 technology are accurately displayed with minimal quantization error. 2 Signal from Device Under Test Debug in High Definition with hd4096 Oscilloscopes with HD4096 have a variety of benefits that allow the user to debug in high definition. Waveforms displayed by high definition oscilloscopes are cleaner and crisper. More signal details can be seen and measured; these measurements are made with unmatched precision resulting in better test results and shorter debug time. Clean, Crisp Waveforms More Signal Details When compared to waveforms Signal details often lost in the Unmatched Measurement Precision captured and displayed by 8-bit noise are clearly visible and easy to Precise measurements are critical for oscilloscopes, waveforms captured distinguish when captured on effective debug and analysis. HD4096 with HD4096 technology are oscilloscopes with HD4096. Details enables oscilloscopes to deliver dramatically crisper and cleaner. which were previously difficult to unmatched measurement precision to Oscilloscopes with HD4096 acquire even see can now be easily seen and improve testing capabilities and provide waveforms at high resolution, high measured. Using the oscilloscope better results. sample rate and low noise to display zoom capabilities gives an even closer the most accurate waveforms. look at the details for unparalleled insight to the signals on screen. 8-bit 12-bit A B A C B A Clean, Crisp Waveforms | Thin traces show the actual waveform with minimal noise interference B More Signal Details | Waveform details lost on an 8-bit oscilloscope can now be clearly seen C Unmatched Measurement Precision | Measurements are more precise and not affected by quantization noise C 3 Touch Screen Simplicity Don’t waste time searching through a complex menu opened. Measurements can be touched to adjust their structure to find the proper setting. Configuring the settings and cursors can be positioned precisely by touch- HDO4000 is simple thanks to the intuitive touch screen ing and dragging them to the proper location. A box can be user interface. Everything on the screen is interactive. To drawn around a portion of a waveform to create a zoom of adjust channel, timebase, or trigger settings, simply touch that waveform. Even waveform offset and delay can be the associated descriptor box and the appropriate menu is adjusted simply by touching and dragging the waveform. 4 Tools for Efficient Debug and Validation Spectrum Analyzer Mode View the frequency content of signals with spectrum analyzer style controls, easily adjust the frequency span, resolution bandwidth and center frequency. A unique peak search detects spectral components and presents frequency and level details in an interactive table. Use the spectrogram display to see changes in the spectrum over time. WaveScan Advanced LabNotebook Documentation and Serial Bus Trigger and Decode Search and Find Tool Report Generation Tool View decoded protocol information Quickly search waveforms for Save all results and data with a single on top of physical layer waveforms runts, glitches or other anomolies button press and create custom and trigger on protocol specific with WaveScan. reports with LabNotebook. messages. Sequence Mode Acquisition Advanced Math and Measure History Mode Waveform Playback Capture many fast pulses in quick Use automatic measurement Scroll back in time to isolate succession or events separated by parameters with statistics and anomalies that have previously long periods of time. histicons as well as math functions to been captured to quickly find the understand every waveform detail. source of the problem. 5 HDO4000 - High Definition Oscilloscope HDO4000 High Definition Oscilloscopes combine Teledyne LeCroy’s HD4096 high definition technology with long memory and powerful debug tools in a compact form factor with a 12.1” touch screen display. 1. Only 13 cm (5”) Deep – The most space-efficient oscilloscope for your bench from 200 MHz to 1 GHz 2. 12.1” Widescreen (16 x 9) high resolution WXGA color touch screen display. The most time-efficient user interface is even easier to use with a built-in stylus 3. Local language user interface – Select from 10 language preferences. Add a front panel overlay with your local language 4. “Push” Knobs – All knobs have push functionality that provides shortcuts to common actions such as Set to Variable, Find Trigger Level, Zero Offset, and Zero Delay 1 8 9 6 2 5. Waveform Control Knobs – Control channel, zoom, math and memory traces with the multiplexed vertical and horizontal knobs 6. Dedicated Cursor Knob – Select type of cursor, position them on your signal, and read values 3 without ever opening a menu 7. Dedicated buttons to quickly access popular debug tools. 8. Easy connectivity with two convenient USB 4 ports on the front, two on the side 9. Rotating and Tilting Feet provide 4 different viewing positions 10. Auxiliary Output and Reference Clock 5 Input/Output connectors for connecting to 6 other equipment 11. USBTMC (Test and Measurement Class) port simplifies programming 7 8 10 11 9 Document and Share: • Quickly save all files with LabNotebook • Create custom reports with LabNotebook • Save to internal solid state or network drive • Print to a USB printer • Save to USB memory stick • Connect with LAN or GPIB • View data on a PC with free WaveStudio utility 7 Identify and Isolate Problems Faster Advanced Waveform Capture with Sequence Mode Use Sequence mode to store up to 10,000 triggered events as “segments” into memory. This can be ideal when capturing many fast pulses in quick succession or when capturing events separated by long time periods. Sequence mode provides timestamps for each acquisition and minimizes dead-time between triggers to less than 1 μs. Combine Sequence mode with advanced triggers to isolate rare events over time and analyze afterwards. WaveScan Advanced Search WaveScan provides powerful isolation capabilities that hardware triggers can’t provide. WaveScan provides the ability to locate unusual events in a single capture (i.e., capture and search), or “scan” for an event in many acquisitions over a long period of time with more than 20 search modes. Advanced Math and Measure With math functions including averaging, enhanced resolution and FFT plus a wide variety of measurement parameters the HDO4000 can measure and analyze every aspect of a waveform. By utilizing HD4096 technol- 8 Since the scanning “modes” are not hours or days, enabling faster ogy, the HDO4000 measures 16 times simply copies of the hardware triggers, debugging. When used in multiple more precisely than traditional 8-bit the utility and capability is much higher. acquisitions, WaveScan builds on the architectures. Beyond just measuring For instance, there is no “frequency” traditional Teledyne LeCroy strength waveforms, the HDO4000 provides trigger in any oscilloscope, yet of fast processing of data. Quickly scan statistics, histicons and trends to show WaveScan allows for “frequency” millions of events looking for unusual to be quickly “scanned.” This allows occurrences, and do it much faster how waveforms change over time. the user to accumulate a data set of and more efficiently than other unusual events that are separated by oscilloscopes can. History Mode Waveform Playback Scroll back in time using History Mode to view previous waveforms and isolate anomalies. Use cursors and measurement parameters to quickly find the source of problems. History mode is always available with a single button press, no need to enable this mode and never miss a waveform. Go Back in Time to Identify the Source of a Problem LabNotebook The LabNotebook feature of HDO4000 provides a report generation tool to save and document all your work. Saving all displayed waveforms, relevant settings, and screen images is all done through LabNotebook, eliminating the need to navigate multiple menus to save all these files independently. One-touch Functionality print er Save You r Work Reca ll Jo bs Waveform V/div T/div Memory Length Sample Rate Measurement Math Hard Drive usb Drive oscilloScope Set Up email FLASHBACK FLASHBACK FLASHBACK ork Your W t n e m Docu LabNotebook Screen Dump Easy report generation helps you share your findings and communicate important results. LabNotebook adds a simple way to report your work and save all essential waveforms, settings, and screen images. Quickly save all the necessary files with LabNotebook in a single button press. Recall your settings from any report by using the Flashback capability. 9 Spectrum Analyzer Mode Key Features • Spectrum analyzer style controls for the oscilloscope • • Select from six vertical scales Automatically identify frequency peaks • Display up to 20 markers, with interactive table readout of frequencies and levels • Easily make measurements with reference and delta markers • Automatically identify and mark fundamental frequency and harmonics • Simplify Analysis of FFT Power Spectrum Get better insight to the frequency content of any signal with use of the Spectrogram shows how spectra Spectrum Analyzer mode on the HDO4000. This mode provides a spectrum changes over time in 2D or analyzer style user interface with controls for start/stop frequency or center 3D views frequency and span. The resolution bandwidth is automatically set for best analysis or can be manually selected. Vertical Scale can be selected as dBm, dBV, dBmV, dBuV, Vrms or Arms for proper viewing and analysis while the unique peak search automatically labels spectral components and presents frequency and level in an interactive table. Utilize up to 20 markers to automatically identify harmonics and quickly analyze frequency content by making measurements between reference and delta markers. To monitor how the spectrum changes over time, view the spectrogram which can display a 2D or 3D history of the fequency content. Spectrum analyzer style controls simplify waveform analysis in the frequency domain. 10 power Analyzer option Key Features • Quickly analyze power conversion circuits • Automatic switching device measurements • Color coded overlay to identify power losses • Control loop and time domain response analysis • Line power and harmonics tests to IEC 61000-3-2 Power Analyzer Automates Switching Device Loss Measurements Quickly measure and analyze the operating characteristics of power conversion devices and circuits with the Power Analyzer option. Critical power switching device measurements, control loop modulation analysis, and line power harmonic testing are all simplified with a dedicated user interface and automatic measurements. Areas of turn-on, turn-off, and conduction loss are all identified with color-coded waveform overlays for faster analysis. Power Analyzer provides quick and easy setup of voltage and current inputs and makes measurements as simple as the push of a button. Tools are provided to help reduce sources of measurement errors and the measurement Teledyne LeCroy has a variety of probes and probing accessories such as high common mode rejection ratio (CMRR) differential amplifiers, differential probes, current probes, and deskew fixtures. parameters provide details of single cycle or average device power losses. Beyond the advanced power loss measurement capabilities, the Power Analyzer modulation analysis capabilities provide insight to understand control loop response to critical events such as a power supply’s soft start performance or step response to line and load changes. The Line Power Analysis tool allows simple and quick pre-compliance testing to EN 61000-3-2. 11 Serial Trigger and Decode Options Debugging serial data busses can Protocol decoding is shown directly be confusing and time consuming. on the waveform with an intuitive, The serial data trigger and decode color-coded overlay and presented options for HDO4000 provide time in binary, hex or ASCII. Decoding saving tools for serial bus debug and on the HDO4000 is fast even with validation. long memory and zooming in to the The serial data trigger will quickly waveform shows precise byte by byte isolate events on a bus eliminating decoding. the need to set manual triggers and To further simplify the debug process hoping to catch the right information. all decoded data can be displayed in Trigger conditions can be entered a table below the waveform grid. in binary or hexadecimal formats Selecting an entry in the table with and conditional trigger capabilities the touch screen will display just even allow triggering on a range of that event. Additionally, built-in different events. search functionality will find specific Supported Serial Data Protocols • I2C, SPI, UART • CAN, LIN, FlexRay™, SENT • USB 1.0/1.1/2.0, USB 2.0-HSIC • Audio (I2S, LJ, RJ, TDM) • MIL-STD-1553, ARINC 429 • MIPI D-PHY, DigRF 3G, DigRF v4 decoded values. View decoded protocol information on top of physical layer waveforms and trigger on protocol specific messages. 12 probes The right probe is an essential tool for accurate signal capture and Teledyne LeCroy offers an extensive range of probes to meet virtually every probing need. ZS Series High Impedance Active Probes ZS2500, ZS1500, ZS1000, ZS2500-QUADPAK, ZS1500-QUADPAK, ZS1000-QUADPAK The ZS Series probes provide high impedance and an extensive set of probe tips and ground accessories to handle a wide range of probing scenarios. The high 1 MΩ input resistance and low 0.9 pF input capacitance mean this probe is ideal for all frequencies. The ZS Series probes provide full system bandwidth for all Teledyne LeCroy oscilloscopes having bandwidths of 1 GHz and lower. Differential Probes (200 MHz – 1.5 GHz) ZD1500, ZD1000, ZD500, ZD200 High bandwidth, excellent common-mode rejection ratio (CMRR) and low noise make these active differential probes ideal for applications such as automotive development (e.g. FlexRay) and failure analysis, as well as wireless and data communication design. The ProBus interface allows sensitivity, offset and common-mode range to be displayed on the oscilloscope screen. High Voltage Differential Probes ADP305, ADP300, AP031 Low cost active differential probes are intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers. High Voltage Passive Probes PPE1.2KV, PPE20KV, PPE2KV, PPE4KV, PPE5KV, PPE6KV The PPE Series includes five fixed-attenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV. All fixed-attenuation, standard probes automatically rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation of the probe. Current Probes CP031, CP030, AP015, CP150, CP500, DCS015 Available current probes reach bandwidths of 100 MHz, peak currents of 700 A and sensitivities of 10 mA/div. Use multiple current probes to make measurements on threephase systems or a single current probe with a voltage probe to make instantaneous power measurements. Teledyne LeCroy current probes enable the design and testing of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies. 13 specifications HDO4022 HDO4024 HDO4032 HDO4034 HDO4054 HDO4104 500 MHz 700 ps typical 4 1 GHz 450 ps typical 4 Vertical Bandwidth (@ 50Ω) Rise time Input Channels Vertical Resolution Sensitivity DC Gain Accuracy BW Limit Maximum Input Voltage Input Coupling Input Impedance Offset Range Offset Accuracy 200 MHz 1.75 ns typical 350 MHz 1 ns typical 2 4 2 4 12-bits; up to 15-bits with enhanced resolution (ERES) 50 Ω: 1mV/div - 1 V/div; 1 MΩ: 1 mV/div - 10 V/div ±(0.5%) Full Scale, offset at 0 V 20 MHz, 200 MHz 50 Ω: 5 Vrms; 1 MΩ: 400 V max (DC + Peak AC ≤ 10 kHz) 50 Ω: DC, GND; 1 MΩ: AC, DC, GND 50 Ω ±2.0%, 1 MΩ ±2.0% || 15 pF 50 Ω: 1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 1 V: ±10 V 1 MΩ: 1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 100 mV: ±16 V, 102 mV - 198 mV: ±80V, 200 mV - 1 V: ±160 V, 1.02 V -10 V: ±400 V ±(1.0% of offset value + 0.5%FS + 0.02% of max offset + 1 mV) Acquisition Sample Rate (Single-shot) Sample Rate (Repetitive) Record Length Acquisition Modes Timebase Range Timebase Accuracy 2.5 GS/s 125 GS/s Standard -STD: 12.5 Mpts/ch (all channels) 25 Mpts (interleaved) Optional -L: 25 Mpts/ch (all channels), 50 Mpts (interleaved) Real Time, Roll, RIS (Random Interleaved Sampling), Sequence (Segmented Memory up to 10,000 segments with 1μs intersegment time) 20 ps/div–10000 s/div; RIS available at ≤ 10 ns/div; Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s ±2.5 ppm for 5 to 40C + 1.0 ppm/year from calibration Trigger System Modes Sources Coupling Pre-trigger Delay Post-trigger Delay Hold-off Internal Trigger Level Range External Trigger Level Range Trigger Types Auto, Normal, Single, Stop Any input channel, External, Ext/10, or line; slope and level unique to each source (except for line trigger) DC, AC, HFREJ, LFREJ 0-100% of full scale 0-10,000 Divisions 2ns up to 20s or 1 to 1,000,000,000 events ±4.1 Divisions Ext: ±400mV, Ext/10: ±4V Edge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV–720p, 1080i, 1080p), Runt, Slew Rate, Interval (signal or Pattern), Dropout, Qualified (State or Edge) Measure, Zoom and Math Tools Measurement Parameters Zooming Math Functions 14 Up to 8 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base (Low), Delay, Delta Period @ Level, Delta Time @ Level, Duty, Duty @ Level, Edge @ Level, Fall Time (90%–10%), Fall Time (80%–20%), Frequency, Frequency @ level, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Peak-Peak, Period, Period @ Level, Phase, Rise Time (10%–90%), Rise Time (20%–80%), RMS, Skew, Standard Deviation, Time @ Level, Top (High), Width+, Width-. Statistics and Histicons can be added to any measurement and all measurements can be gated. Use front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area. Functions include Sum, Difference, Product, Ratio, Absolute Value, Averaging (summed and continuous), Derivative, Envelope, Enhanced Resolution (to 15-bits), Floor, Integral, Invert, Reciprocal, Rescale (change scale and units), Roof, Square, Square Root, Trend, Zoom and FFT (up to 1 Mpts with power spectrum output and rectangular, VonHann, and FlatTop windows). 2 dual operator math functions may be defined at a time. specifications HDO4022 HDO4024 HDO4032 HDO4034 HDO4054 HDO4104 Probes Standard Probes Probing System One PP017 (5mm) per channel One PP018(5mm) per channel BNC and Teledyne LeCroy ProBus for Active voltage, current and differential probes Display System Display Size Display Resolution 12.1” Wide TFT-LCD Touch-Screen 1280 x 800 Connectivity Ethernet Port USB Host Ports USB Device Port GPIB Port (Optional) External Monitor Port Remote Control (2) 10/100/1000Base-T Ethernet interface (RJ-45 connector) (6) USB Ports Total – (2) Front USB Ports (1) USBTMC Supports IEEE – 488.2 Standard 15-pin D-Type SVGA-compatible DB-15 connector, DVI connector and HDMI connector Via Windows Automation, or via Teledyne LeCroy Remote Command Set Processor/CPU Type Processor Memory Operating System Disk Type Intel B810 Celeron processor 1.6 GHz or better 2 GB Standard Windows Embedded Standard 7 64-Bit Solid State Drive 64 GB or greater Power Requirements Voltage Power Consumption (Nominal) Max Power Consumption 100-240 VAC + 10% at 45-440 Hz; Automatic AC Voltage Selection 200 W / 200 VA Max Power Consumption 320 W / 320 VA (with all PC peripherals and active probes connected to 4 channels) Environmental Temperature Humidity Altitude Operating: 5 °C to 40 °C; Non-Operating: -20 °C to 60 °C Operating: 5% to 90% relative humidity (non-condensing) up to +31 °C, Upper limit derates to 50% relative humidity (non-condensing) at +40 °C; Non-Operating: 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F Operating: 3,048 m (10,000 ft) max at ≤ 30C; Non-Operating: Up to 12,192 meters (40,000 ft) Physical Dimensions (HWD) Weight 11.48”H x 15.72”W x 5.17“D (291.7 mm x 399.4 mm x 131.31 mm) 5.86 kg (12.9 lbs) Regulatory CE Certification UL and cUL Listing Low Voltage Directive 2006/95/EC EN 61010-1:2010, EN 61010-2-030:2010 EMC Directive 2004/108/EC EN 61326-1:2006, EN61326-2-1:2006 UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition) CAN/CSA C22.2 No.61010-1-12 15 ordering information Product Description Product Code HDO 4000 Oscilloscopes HDO4022 HDO4024 HDO4032 HDO4034 HDO4054 HDO4104 ÷10 Passive Probe (Total of 1 Per Channel), Getting Started Guide, Anti-virus Software (Trial Version), Microsoft Windows Embedded Standard 7 P 64-Bit License, Commercial NIST Traceable Calibration with Certificate, Power Cable for the Destination Country, 3-year Warranty Memory Option 25 Mpts/CH (50 Mpts interleaved) memory HDO4K-L Hardware Options Removable Solid State Drive Package (includes removable solid state drive kit and two hard drives Additional Removable Solid State Drive HDO4K-RSSD HDO4K-RSSD-02 General Accessories USB2-GPIB HDO4K-SOFTCASE HDO4K-RACK HDO4K-POUCH Local Language Overlays HDO4K-A-FP-GERMAN HDO4K-A-FP-FRENCH HDO4K-A-FP-ITALIAN HDO4K-A-FP-SPANISH HDO4K-A-FP-JAPANESE HDO4K-A-FP-KOREAN HDO4K-A-FP-CHNES-TR HDO4K-A-FP-CHNES-SI HDO4K-A-FP-RUSSIAN 250 MHz Passive Probe for HDO4000 and PP017 HDO6000, 10:1, 10 MOhm 500 MHz Passive Probe for HDO4000 and PP018 HDO6000, 10:1, 10 MOhm ZS1500-QUADPAK Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 MΩ High Impedance Active Probe ZS1000-QUADPAK Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 MΩ High Impedance Active Probe ZD200 200 MHz, 3.5 pF, 1 MΩ Active Differential Probe ZD500 500 MHz, 1.0 pF, 1 MΩ Active Differential Probe ZD1000 1 GHz, 1.0 pF, 1 MΩ Active Differential Probe ZD1500 1.5 GHz, 1.0 pF, 1 MΩ Active Differential Probe 1,400 V, 100 MHz High-Voltage Differential Probe ADP305 1,400 V, 20 MHz High-Voltage Differential Probe ADP300 1 Ch, 100 MHz Differential Amplifier DA1855A with Precision Voltage Source CP031 30 A; 100 MHz Current Probe – AC/DC; 30 Arms; 50 Apeak Pulse 30 A; 50 MHz Current Probe – AC/DC; 30 Arms; 50 Apeak Pulse CP030 AP015 30 A; 50 MHz Current Probe – AC/DC; 30 Arms; 50 Apeak Pulse CP150 150 A; 10 MHz Current Probe – AC/DC; 150 Arms; 500 Apeak Pulse CP500 500 A; 2 MHz Current Probe – AC/DC; 500 Arms; 700 Apeak Pulse 10:1/100:1 200/300 MHz, 50 MΩ High-voltage Probe PPE1.2KV 600 V/1,2 kV Max. Volt. DC 100:1 400 MHz 50 MΩ 2 kV High-voltage Probe PPE2KV 100:1 400 MHz 50 MΩ 4 kV High-voltage Probe PPE4KV 1000:1 400 MHz 50 MΩ 5 kV High-voltage Probe PPE5KV 1000:1 400 MHz 50 MΩ 6 kV High-voltage Probe PPE6KV 1000:1 100 MHz 50 MΩ 6 kV High-voltage Probe PPE20KV 20 kV Max. Volt DC + 40 kVPeak AC Customer Service Software Options Electrical Telecom Mask Test Package Spectrum Analysis Option Power Analysis Option FlexRay Trigger and Decode Option HDO4K-FlexRaybus TD HDO4K-SENTbus D SENT Decode Option MIL-STD-1553 Trigger and Decode Option HDO4K-1553 TD ARINC 429 Symbolic Decode Option HDO4K-ARINC429bus DSymbolic USB 2.0 Trigger and Decode Option HDO4K-USB2bus TD USB2-HSIC Decode Option HDO4K-USB2-HSICbus D HDO4K-DPHYbus D D-PHY Decode Option DigRF 3G Decode Option HDO4K-DigRF3Gbus D DigRF v4 Decode Option HDO4K-DigRFv4bus D HDO4K-Audiobus TD Audiobus Trigger and Decode Option for I2S, LJ, RJ, and TDM Probes and Amplifiers Included with Standard Configuration German Front Panel Overlay French Front Panel Overlay Italian Front Panel Overlay Spanish Front Panel Overlay Japanese Front Panel Overlay Korean Front Panel Overlay Chinese (Tr) Front Panel Overlay Chinese (Simp) Front Panel Overlay Russian Front Panel Overlay Product Code Serial Data Options (cont’d) 200 MHz, 2.5 GS/s, 2 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 200 MHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 350 MHz, 2.5 GS/s, 2 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 350 MHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 500 MHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display 1 GHz, 2.5 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Touch Display External GPIB Accessory Soft Carrying Case Rack Mount Accessory Accessory Pouch Product Description HDO4K-ET-PMT HDO4K-SPECTRUM HDO4K-PWR Serial Data Options I2C, SPI and UART Trigger and Decode Option HDO4K-EMB HDO4K-I2Cbus TD I2C Bus Trigger and Decode Option SPI Bus Trigger and Decode Option HDO4K-SPIbus TD UART and RS-232 Trigger and Decode Option HDO4K-UART-RS232bus TD CAN, LIN and FlexRay Trigger and Decode Option HDO4K-AUTO LIN Trigger and Decode Option HDO4K-LINbus TD HDO4K-CANbus TD CAN TD Trigger and Decode Option 1-800-5-LeCroy teledynelecroy.com Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes: • No charge for return shipping • Long-term 7-year support • Upgrade to latest software at no charge Local sales offices are located throughout the world. Visit our website to find the most convenient location. © 2012 Teledyne LeCroy. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders. hdo4k-ds-15nov12