LABORATORY DCS Series 1000-3000 WATTS PROGRAMMABLE DC SUPPLY Features • • • • • High power density Remote voltage sense & remote programming Wide range of output voltages High programming resolution with ethernet interface Remote control Specifications OPERATING INPUT Input voltage 1KW: 200-250VAC, single phase; 100-132VAC single phase, internal jumper selectable (see M1 option) 1.2KW: 200-250VAC, single phase; 100132VAC single phase, internal jumper selectable (see M1 option) 3KW: 190-250VAC, three phase; 200-250VAC, single phase (Note: Max.power output of 3KW supplies must be limited to 2.5KW for single phase input) Frequency 47-63Hz for both single and three phase input Current 1KW: 15A typ at 115VAC, 8A typ at 230VAC, 1.2KW: 18A typ at 115VAC, 9A typ at 230VAC, 3KW: 20A typ at 230VAC single phase, 14A typ at 230VAC three phase Soft start Efficiency See table Remote sense The maximum allowed sense line drop is 4V per line (2V on the DCS 8 and 10V 1KW and 1.2KW models and 1V/ line for all 3KW models) Remote programming External jumper via rear panel connectors J3. Overvoltage protection Crowbar type adjustable from 5-110% Protection rated output using front panel control (local or remote program selectable via J3 jumper) Remote analog programming Linearity: +/-1% Accuracy: +/-5% Software LabVIEW® driver for M9C/M85 (Contact Powerbox) Regulatory compliance CE Mark on all models, FCC Part 15 Class A UL1012 and CSA 22.2 #220 (1 and 1.2 KW only) Line current is lower than full load peak value during turn-on or power application after restart ENVIRONMENTAL Options and Accessories Operating temperature 0°C to 50° (No De-rating) Storage temperature -40°C to 85°C Humidity range 0-80% RH, non condensing REMOTE INTERFACE OPTIONS Cooling Internal fan with over-temperature protection M9C Internal IEEE-488/RS 232 interface M13 Locking shafts (front panel potentiometers) M32 Master/slave cable configured for two or more units M33 M51A Replace input connector with terminal block (3kW only) Isolated analog programming control of V/I/OVP and isolated V/I monitor outputs up to 500V relative to the supply’s return line Multichannel slave interface Front panel binding posts for 1kw or 1.2 kW, Models 30A, 100V. Not compatible with M9C, M85, M130, M131, M133, M135, M136 LXI compliant 10/100 Base T Ethernet remote control master interface; includes web server for direct control of power supply via web browser (MS Internet Explorer 6.0 or later) OUTPUT Voltage adjustment Zero to rated output Current adjustment Zero to rated output Ripple & Noise See table Regulation (Line or Load) Voltage: 0.1% Current: 0.1% Transient response Typically recovers in < 1ms to 1% of steady-state output voltage (within 1% of Vmax) for 70-100% or 100-70% load change. 500s typical Stability +/-0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature Temperature Coefficient 0.02%/°C of maximum output voltage 0.03%/°C of maximum output current INPUT VOLTAGE OPTIONS M1 M85 M102 M130 M131 M135 16-bit slave interface option for use with a M130 master (3 ft. control cable included) Output disconnect and polarity reversal controlled via SCPI commands. Limited to 1k or 1.2 kW, 300V, 60A M130 & M133 combination M136 M131 & M133 combination 105-330-26 Rack slide kit (3kW) M133 484 Factory configured for 115VAC input (1 and 1.2kW only) LABORATORY DCS Series 1000-3000 WATTS PROGRAMMABLE DC SUPPLY CONSTANT CURRENT MODE* MODEL COMBINED REGULATION LINE AND LOAD % RIPPLE (RMS) TEMP. COEFF. VOLTAGE %/°C (TYP) PROGRAMMING INPUT CURRENT, A CASE VOLTAGE CONSTANTS CURRENT NORMAL MODE DRIFT % % EFFICIENCY IO MAX 230V 208V % (TYP) SINGLE THREE OHMS/A V/A (TYP) PHASE PHASE DCS 8-140E 0.2 180 0.03 0.05 DCS 10-120E 0.2 153 0.03 0.05 DCS 20-60E 0.2 30 0.03 0.05 DCS 33-36E 0.2 11 0.03 0.05 DCS 40-30E 0.2 9 0.03 0.05 DCS 50-24E 0.2 8.5 0.03 0.05 DCS 60-20E 0.2 6.6 0.03 0.05 DCS 80-15E 0.2 6 0.03 0.05 DCS 100-12E 0.2 3.6 0.03 0.05 DCS 150-8E 0.2 2.3 0.03 0.05 DCS 300-4E 0.2 1.2 0.03 0.05 * Typical resolution is 0.02% **RMS ripple from 20Hz to 300kHz ***Consult factory Dimension: 1RU or 44mm (H) x 482mm (W) x 444mm (D) ; Weight: 8.6kg86 35.7 41.7 83.3 138.9 166.7 208.3 250 333.3 416.7 625 1250 9 9 9 9 9 9 9 9 9 9 9 0-10V= 0-100% Io or 0-5V= 0-100% Io N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 82 82 82 84 84 84 85 85 85 85 85 I I I I I I I I I I I DSC 3kW Series TEMP. COMBINED CONSTANT VOLTAGE MODE* COEFF. VOLTAGE REGULATION DRIFT % CURRENT RIPPLE NOISE TRANSIENT VOLTAGE LINE AND VMAX VOLTAGE ADC @ (RMS)** (P-P) RESPONSE %/°C LOAD % (TYP) VDC 50°C (TYP.) (TYP) TIME (TYP) (TYP) OUTPUT POWER MODEL DCS 8-350E DCS 12-250E DCS 20-150E DCS 40-75E DCS 55-55E DCS 60-50E DCS 80-37E DCS 150-20E 0-8 0-12 0-20 0-40 0-55 0-60 0-80 0-150 0-350 0-250 0-150 0-75 0-55 0-50 0-37 0-20 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 15mV 10mV 10mV 20mV 20mV 20mV 20mV 30mV 100mV 100mV 100mV 100mV 100mV 100mV 100mV 200mV 1000s 1000s 1000s 1000s 1000s 1000s 1000s 1000s 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 PROGRAMMING TEMP. VOLTAGE CONSTANTS CURRENT COEFF. MODE DRIFT % % VOLTAGE I MAX O RIPPLE %/°C OHMS/A V/A (TYP) (RMS) (TYP) CONSTANT CURRENT MODE* MODEL COMBINED REGULATION LINE AND LOAD % DCS 8-350E 0.2 870 0.03 0.05 DCS 12-250E 0.2 400 0.03 0.05 DCS 20-150E 0.2 100 0.03 0.05 DCS 40-75E 0.2 75 0.03 0.05 DCS 55-55E 0.2 40 0.03 0.05 DCS 60-50E 0.2 33 0.03 0.05 DCS 80-37E 0.2 20 0.03 0.05 DCS 150-20E 0.2 10 0.03 0.05 * Typical resolution is 0.02% **RMS ripple from 20Hz to 300kHz ***Consult factory Dimension: 2RU or 88mm (H) x 482mm (W) x 444mm (D) ; Weight: 15kg 486 14.7 20 33.3 66.7 90.9 100 135 250 0-10V= 0-100% I0 or 0-5V= 0-100% I0 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 PROGRAMMING CONSTANTS VOLTAGE MODES OHMS/V V/V 625 416.7 250 125 90.9 83 62.5 33.3 0-10V = 0-100% Vo or 0-5V = 0-100% Vo INPUT CURRENT, A NORMAL 230V SINGLE PHASE 208V THREE PHASE 24 26 26 26 26 26 26 26 13 14 14 14 14 14 14 14 CASE EFFICIENCY % (TYP) 82 82 82 86 82 86 86 86 II II II II II II II II LABORATORY DCS Series 1000-3000 WATTS PROGRAMMABLE DC SUPPLY DSC 1kW Series OUTPUT POWER MODEL DCS 8-125E DCS 10-100E DCS 20-50E DCS 33-33E DCS 40-25E DCS 50-20E DCS 60-18E DCS 80-13E DCS 100-10E DCS 150-7E DCS 300-3.5E DCS 600-1.7E CONSTANT COMBINED REGULATION CURRENT LINE AND VOLTAGE RIPPLE ADC @ LOAD % VDC (RMS)** (TYP.) 50°C 0-8 0-10 0-20 0-33 0-40 0-50 0-60 0-80 0-100 0-150 0-300 0-600 0-125 0-100 0-50 0-33 0-25 0-20 0-18 0-13 0-10 0-7 0-3.5 0-1.7 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 4mV 4mV 4mV 4mV 4mV 4mV 4mV 4mV 6mV 12mV 20mV 50mV PROGRAMMING CONSTANTS TEMP. VOLTAGE MODES COEFF. VOLTAGE DRIFT % NOISE TRANSIENT VOLTAGE VMAX (P-P) RESPONSE OHMS/V V/V %/°C (TYP) (TYP) TIME (TYP) (TYP) VOLTAGE MODE* 60mV 60mV 60mV 60mV 60mV 60mV 60mV 60mV 60mV 160mV 200mV 300mV 500s 500s 500s 500s 500s 500s 500s 500s 500s 500s 500s 500s 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 PROGRAMMING TEMP. VOLTAGE CONSTANTS CURRENT COEFF. MODE DRIFT % % VOLTAGE IO MAX RIPPLE %/°C OHMS/A V/A (TYP) (RMS) (TYP) CONSTANT CURRENT MODE* MODEL COMBINED REGULATION LINE AND LOAD % DCS 8-125E 0.2 160 0.03 0.05 40 DCS 10-100E 0.2 128 0.03 0.05 50 DCS 20-50E 0.2 25 0.03 0.05 100 DCS 33-33E 0.2 10 0.03 0.05 151.5 DCS 40-25E 0.2 7 0.03 0.05 200 DCS 50-20E 0.2 7 0.03 0.05 250 DCS 60-18E 0.2 6 0.03 0.05 277.8 DCS 80-13E 0.2 4 0.03 0.05 384.6 DCS 100-10E 0.2 3 0.03 0.05 500 DCS 150-7E 0.2 2 0.03 0.05 714.3 DCS 300-3.5E 0.2 1 0.03 0.05 1428.6 DCS 600-1.7E 0.2 1 0.03 0.05 2941.2 * Typical resolution is 0.02% **RMS ripple from 20Hz to 300kHz ***Consult factory Dimension: 1RU or 44mm (H) x 482mm (W) x 444mm (D) ; Weight: 8.6kg 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 625 500 250 151.5 125 100 83 62.5 50 33.3 16.67 8.33 INPUT CURRENT, A NORMAL 0-10V= 0-100% Io or 0-5V= 0-100% Io 0-10V = 0-100% Vo or 0-5V = 0-100% Vo CASE EFFICIENCY % (TYP) 230V SINGLE PHASE 208V THREE PHASE 8 8 8 8 8 8 8 8 8 8 8 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 82 82 82 84 84 84 86 86 86 86 86 I I I I I I I I I I I 9.5 N/A 86 *** DSC 1.2kW Series OUTPUT POWER MODEL VOLTAGE CURRENT VDC ADC @ 50°C DCS 8-140E DCS 10-120E DCS 20-60E DCS 33-36E DCS 40-30E DCS 50-24E DCS 60-20E DCS 80-15E DCS 100-12E DCS 150-8E DCS 300-4E 0-8 0-10 0-20 0-33 0-40 0-50 0-60 0-80 0-100 0-150 0-300 0-140 0-120 0-60 0-36 0-30 0-24 0-20 0-15 0-12 0-8 0-4 COMBINED REGULATION LINE AND LOAD % 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 PROGRAMMING CONSTANTS TEMP. VOLTAGE MODES COEFF. VOLTAGE DRIFT % VOLTAGE TRANSIENT VMAX %/°C (TYP) RESPONSE OHMS/V V/V (TYP) TIME (TYP) CONSTANT VOLTAGE MODE* RIPPLE (RMS)** (TYP.) NOISE (P-P) (TYP) 5mV 5mV 5mV 5mV 5mV 5mV 5mV 5mV 10mV 15mV 25mV 60mV 60mV 60mV 60mV 60mV 60mV 60mV 60mV 60mV 160mV 200mV 500s 500s 500s 500s 500s 500s 500s 500s 500s 500s 500s 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 Your dependable power partner – www.powerbox.com.au 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 625 500 250 151.5 125 100 83 62.5 50 33.3 16.67 0-10V = 0-100% Vo or 0-5V = 0-100% Vo 485 LABORATORY DCS Series 1000-3000 WATTS PROGRAMMABLE DC SUPPLY Options & Accesssories INPUT VOLTAGE OPTIONS M1 Factory configured for 115 VAC input (1 and 1.2 kW only) REMOTE INTERFACE OPTIONS J3 PROGRAM AND SENSE 1 90-250 VAC Remote Shutdown 14 TTL Shutdown 2 Shutdown Return 15 +12 VDC M9C Internal IEEE-488/RS 232 interface (Supports only 12-bit slaves) M13 Locking shafts (front panel potentiometers) 3 OVP Program 16 1 mACurrent Source (OVP) M32 Master/slave cable configured for two or more units 4 Remote/Local Status Indicator 17 OVP Indicator M33 Replace input connector with terminal block(3 kW only) 5 Mode Status Indicator 18 Thermal S/DN Status M51A Isolated analog programming control 6 Ground 19 0-5V Voltage Monitor M102 Front Panel Binding Posts (1 kW and 1.2 kW only?30A) M85 12-bit slave interface 7 0-5V Current Monitor 20 Remote Voltage Select Voltage Control 21 1 mA Current Source (V) M130 Ethernet/RS232 Interface (Supports both 12- & 16-bit slaves) 8 M131 16-bit slave interface 9 Voltage Program Input 22 1 mA Current Source (I) M133 Output disconnect and polarity reversal relays* 10 Current Program Unit 23 Remote Current Select M135 Output disconnect and polarity reversal relays** 11 Current Control 24 Return M136 Output disconnect and polarity reversal relays*** 12 Return Sense 25 POS Output (8-100V Models Only) 13 POS Sense (8-100V Models Only 105-330-26 Rack slide kit (3 kW only) * Requires M9C ** Includes option M130 ***Includes option M131 Technical Illustrations 1KW AND 1.2KW 3KW Your dependable power partner – www.powerbox.com.au 487