POWER-ONE DFC6U5S12

DFC6 SERIES
SINGLE OUTPUT
FEATURES
• Ultra-Wide 3.5 to 16 Volt Input Range
• Input Filtered
• 6 Watts of Output Power
• Efficiencies to 77%
• 700V Isolation
• Low Input to Output Capacitance
• Ultra-Wide Input Range (4:1)
BOTTOM VIEW
2.00
(50.80)
0.300
(7.62)
SIDE VIEW
.040 (1.02) DIA
4 PLACES
3
1
0.000
0.200
(5.08)
0.500
(12.70)
0.60
(15.2)
1.00
(25.40)
2
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
X.XXX dimensions: ±0.005 inches
NOTES
(1)
(2)
(3)
(4)
All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise noted.
Refer to the Technical Reference Section for the definition of terms, measurement circuits and other
information.
The functional temperature range is intended to give an additional data point for use in evaluating this
power supply. At the low functional temperature the power supply will function with no side effects,
however, sustained operation at the high functional temperature will reduce expected operational life.
The data sheet specifications are not guaranteed beyond the case operating range.
The case Thermal Impedance is specified as the case temperature rise over ambient per package
dissipated.
Reduced output power available with 3.5V input. Full power is available above 4.6V input. See input
voltage derating curve for more information
Rev. 04/2000
1
0.45
(11.43)
0.000
0.80
(20.32)
0.000
0.60
(15.2)
4
0.3
(7.62)
DESCRIPTION
Designed for digital, ECL, and analog application, the DFC6
Series will provide up to 6 watts in an industry standard package.
Ultra-wide range input voltage allows operation from battery
power as well as system power. The output is electrically isolated,
thereby allowing the output to be configured as a positive or
negative output voltage. Fully isolated and filtered outputs permit
usage in sensitive and low noise circuits.
The 100KHz operating frequency of the DFC6 Series allows an
increased power density while including adequate heat sinking
and input/output filtering. This eliminates the need for external
components in most applications.
DFC6 SERIES – SINGLE OUTPUT
NOTES
required for operation, however it is recommended that 1F to
10F of tantalum and 0.001 to 0.1F ceramic capacitance be
selected for reduced system noise. Additional output capacitance
may be added for increased filtering, but should not exceed 400F.
(1) All parameters measured at Tc=25°C, nominal input voltage and full rated load unless otherwise
noted. Refer to the Technical Reference Section for the definition of terms, measurement circuits and
other information.
(2) Reduced output power available at 3.5V input. Full output power is available above 4.6V input. See
input voltage derating curve for more information.
(3) Noise is measured per Technical Reference Section. Measurement bandwidth is
0-20 MHz for peak-peak measurements, 10 kHz to 1 MHz for RMS measurements. Output noise is
measured with a 1µF/35V Tantalum capacitor located 1" away from the converter to simulate PCB
standard decoupling.
(4) Short term stability is specified after a 30 minute warmup at full load, constant line and recording the
drift over a 24 hour period.
(5) No minimum load required for operation. Dynamic regulation may degrade when run with less
than 5% load.
Output Power
The available output power of the DFC6 Series is reduced when
operating below 4.6 volts. See Input Voltage Derating curve. Below
4.6 volts the output power is linearly derated from 100% at 4.6
volts to 50% at 3.5 volts.
Negative Outputs
A negative output voltage may be obtained by connecting the
+OUT to circuit ground and connecting -OUT as the negative
output.
DFC6 SERIES APPLICATION NOTES:
External Capacitance Requirements
No external capacitance is required for operation of the DFC6
Series. To meet the reflected ripple requirements of the converter,
an input impedance of less than 0.15 Ohms from DC to 200KHz
is required. If a capacitive input source is farther than 1” from the
converter, an additional capacitor may be required at the input
pins for proper operation. External output capacitance is not
2
DFC6 SERIES – SINGLE OUTPUT
DFC6 SERIES BLOCK DIAGRAM
OUTPUT POWER DERATING
SHIELDED ISOLATION TRANSFORMER
6
3
+ OUTPUT
4
- OUTPUT
5
+ INPUT
1
– INPUT
2
CURRENT
MODE
PWM
+
POWER OUTPUT
+
+
4
3
2
–
ISO AMP
NONCONDUCTIVE PLASTIC CASE
1
LOW TC
BANDGAP
REFERENCE
0
40
50
60
70
80
AMBIENT TEMPERATURE
90
Typical Performance: (Tc=25°C, Vin=Nom VDC, Rated Load)
EFFICIENCY Vs. LOAD
INPUT CURRENT (AMPS)
70
LINE = 16VDC
3.5
3.0
2.5
2.0
1.5
100% LOAD
1.0
0.5
50% LOAD
60
0
10
20
30
40
50
60
70
80
90 100
0
2
LOAD (%)
EFFICIENCY Vs. LINE INPUT VOLTAGE
RMS INPUT CURRENT (AMPS)
EFFICIENCY (%)
50% FULL LOAD
75
100% FULL LOAD
70
65
8
10
10
12
14
.1
5 VOLT OUTPUT
16
100
12
LINE INPUT (VOLTS)
14
16
1.0
75% LOAD
0.6
50% LOAD
0.4
0.2
0.0
7
100000
1000000
INPUT VOLTAGE DERATING
0.8
5
10000
120
100% LOAD
3
1000
FREQUENCY (Hz)
RMS INPUT CURRENT Vs. LINE INPUT
80
6
8
6
12/15 VOLT OUTPUT
1
LINE INPUT (VOLTS)
85
4
4
10
.01
10
0.0
% AVAILABLE POWER
EFFICIENCY (%)
75
OUTPUT IMPEDENCE (OHMS)
4.0
LINE = 5VDC
65
OUTPUT IMPEDENCE Vs. FREQUENCY
INPUT CURRENT Vs. INPUT VOLTAGE
80
9
11
13
LINE INPUT (VDC)
15
17
100
80
60
40
20
0
3.50
3.75
4.00
4.25
4.50
4.75
5.00
LINE INPUT (VDC)
For the Most Up-To-Date Information
www.power-one.com
24 Hours/Day—7 Days/Week
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.