CANDD DNX350-U1A 350 watt dc/dc power supply Datasheet

350 WATT
DC/DC POWER SUPPLY
Product Data Sheet
DNX350
FEATURES
Fully Isolated Outputs
Low Profile: 9” x 4.85” x 2.00”
One, Two, Three and Four
Output Models
Active Current Sharing on V1
Optional Fan Covers
(Top-Mounted or End-Mounted)
Active Inrush Current Limiting
DESCRIPTION
36-72VDC Input
The DNX350 is a compact 350 watt, multiple output power supply
that operates from a 36-72VDC source. All outputs are fully
isolated and regulated. Active current sharing circuitry on Output
#1, together with control functions and alarm options, simplifies
N+1 and redundant applications. Fan and disk drive applications
are handled by the peak current ratings of the auxiliary outputs.
AGENCY APPROVALS
See “Safety” section on page 2 for more information
Website: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.295.4197
C&D Technologies, (NCL)
Milton Keynes MK14 5BU UK
Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be
accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness
of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties,
either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing
or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in user’s specific application.
C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
DNX350 4/2002 REV B
Page 1
Input Specifications
Parameter
Conditions
Min
Typ
Max
Units
36
48
72
VDC
36VDC
25
APK
72VDC
50
APK
Operating Range
DC
Inrush Current Limiting
Efficiency
48VDC at full load
70
%
Remote Sense
Remote Sense is provided on Output #1 and will
compensate for 0.7V of line drop. Remote Sense leads
are protected against open, short and reversal.
Transient Response
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 200 µsec for a 25% load step
change.
Remote On/Off (Optional)
The power supply is turned on with a TTL logic ‘1’ (or open)
signal and turned off by a switch closure or TTL logic ‘0’
referenced to (-) sense terminal.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs
and automatically restarts.
Over Voltage Protection
Output #1: 6.5V ± 0.5 VDC.
The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Safety
Safety Certified to UL/CUL to 1950, File Number E131694.
TUV to EN60950/IEC 950.
Cooling
The unit is designed to operate with 30 CFM of airflow.
Active Inrush Current Limiting
Inrush current is independent of ambient temperature.
Page 2
DNX350 4/2002 REV B
Output Voltages and Maximum Rated Loads
MODEL NUMBER
OUTPUT #1
VOUT
IMAX
OUTPUT #2
VNOM IMAX/IPK
OUTPUT #3
VNOM IMAX/IPK
OUTPUT #4
VNOM IMAX/IPK
DNX350-U1A
+5V
50A
DNX350-U3A
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
-
-
DNX350-U3B
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
-
-
DNX350-U4C
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
± 5V
3.0A
DNX350-U4D
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
± 24V
1.5A
DNX350-U4E
± 5V
50A
± 12V
10A/12A
± 12V
8A/10A
± 12V
3.0A
DNX350-U4F
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 5V
3.0A
DNX350-U4G
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 24V
1.5A
DNX350-U4H
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 12V
3.0A
DNX350-U4I
± 5V
50A
± 15V
10A/12A
± 15V
8A/10A
± 12V
3.0A
Output Specifications
Parameter
Limits
Regulation
Line
± 0.03%
Load
±0.25%
Cross
±0.05%
Minimum Load
Output #1
3.0A
Auxiliary Outputs
0.1A
Parameter
Conditions
Voltage Adustment Range
Nominal line on all outputs
PARD
Min
Typ
Max
±5
Peak-to-peak 20 MHz bandwidth
Units
%
1
% P-P
0
50
°C
-20
+70
°C
Temperature
Operating
Storage
Temperature Coefficient (TC)
DNX350 4/2002 REV B
After half hour warm-up
± 0.02
%/°C
Page 3
Mechanical
6.94
TOP MOUNTED
FAN
FAN OPTION
3.34
1
NO. 1 +V
OUTPUTS
NO. 1 -V
TB1
1
PLUS
2
AIR FLOW
OUTPUT OUTPUT
4
3
ADJ.
ADJ.
MINUS
3
OUTPUT
5
ADJ.
4.85 3.60
3.90
1
1
0.62
0.55
TB2
6-32 MOUNTING LOCATED ON BOTTOM (4x)
8.50
0.25
1.99
9.00
END MOUNTED
FAN
3.00
8.50
0.250
2.15
0.550
J10
TB2
3
2
1
3.900
4.850
J9
AIR FLOW
1.00
OUTPUT NO. 1
RETURN
10-32 STUD
9.00
6-32 THD
4 PLC'S
NOTES: All measurements are in inches
COOLING: The DNX350 is designed to operate with 30 CM airflow.
SHOCK AND VIBRATION: The DNX350 meets the requirements of MIL STD-810D.
WEIGHT: Approximately 3 lbs.
Terminal Block 1
POS
FUNCTION
Terminal Block 2
POS
J9 Connector
J10 Connector*
Molex No. 22-28-1090
1
DC +
1
-V2
2
DC -
2
+V2
1
+ Sense
1
DC+
3
-V3
2
- Sense
2
DC-
4
+V3
3
N/C
3
GROUND
-V4
4
N/C
+V4
5
Start Up Sync.
6
N/C
7
Remote Inhibit
8
Current Share
9
Control Signal Rtn
Ground
5
6
FUNCTION
AMP 1-480701-1
PIN
3
Page 4
FUNCTION
OUTPUT NO. 1
10-32 STUD
1
POS
FUNCTION
*Used with end-mounted fan cover,
option “V”
DNX350 4/2002 REV B