IXYS DSEI8-06AS Fast recovery epitaxial diode (fred) Datasheet

DSEI 8
Fast Recovery
Epitaxial Diode (FRED)
VRSM
V
640
640
VRRM
Type
C
A
TO-263 AA
DSEI 8-06AS
NC
V
600
600
A
DSEI 8-06A
DSEI 8-06AS
C (TAB)
Symbol
Test Conditions
IFRMS
IFAVM ÿÿ①
IFRM
TVJ = TVJM
TC = 115°C; rectangular, d = 0.5
tP < 10 ms; rep. rating, pulse width limited by TVJM
16
8
130
A
A
A
IFSM
TVJ = 45°C;
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
100
110
A
A
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
85
95
A
A
TVJ = 45°C
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
50
50
A2s
A2s
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
36
37
A2s
A2s
-40...+150
150
-40...+150
°C
°C
°C
50
W
I2t
IFAVM = 8 A
VRRM = 600 V
trr
= 35 ns
TVJ
TVJM
Tstg
Ptot
TC = 25°C
Md
Mounting torque
Maximum Ratings
TO-220 AC
DSEI 8-06A
C
A
C
A = Anode, C = Cathode, NC = No connection
TAB = Cathode
Features
International standard package
JEDEC TO-220 AC & TO-263 AB
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low IRM-values
Soft recovery behaviour
Epoxy meets UL 94V-0
●
●
●
●
●
●
0.4...0.6
Weight
2
Nm
g
●
Applications
Antiparallel diode for high frequency
switching devices
Anti saturation diode
Snubber diode
Free wheeling diode in converters
and motor control circuits
Rectifiers in switch mode power
supplies (SMPS)
Inductive heating and melting
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
●
Symbol
Test Conditions
typ.
Characteristic Values
max.
●
●
IR
TVJ = 25°C
TVJ = 25°C
TVJ = 125°C
VR = VRRM
VR = 0.8 • VRRM
VR = 0.8 • VRRM
20
10
1.5
mA
mA
mA
VF
IF = 8 A;
TVJ = 150°C
TVJ = 25°C
1.3
1.5
V
V
0.98
28.7
V
mW
2.5
60
K/W
K/W
K/W
For power-loss calculations only
TVJ = TVJM
RthJC
RthCK
RthJA
0.5
trr
IF = 1 A; -di/dt = 50 A/ms; VR = 30 V; TVJ = 25°C
35
50
ns
IRM
VR = 350 V; IF = 8 A; -diF/dt = 64 A/ms
L £ 0.05 mH; TVJ = 100°C
2.5
2.8
A
●
●
●
Advantages
High reliability circuit operation
Low voltage peaks for reduced
protection circuits
Low noise switching
Low losses
Operating at lower temperature or
space saving by reduced cooling
●
●
●
① IFAVM rating includes reverse blocking losses at TVJM, VR = 0.8 VRRM, duty cycle d = 0.5
Data according to IEC 60747
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
●
●
●
033
VT0
rT
●
1-2
DSEI 8, 600 V
Fig. 1 Forward current
versus voltage drop.
Fig. 2 Recovery charge versus -diF/dt.
Fig. 3 Peak reverse current versus
-diF/dt.
Fig. 4 Dynamic parameters versus
junction temperature.
Fig. 5 Recovery time versus -diF/dt.
Fig. 6 Peak forward voltage
versus diF/dt.
Dimensions TO-220 AC
Dim.
Millimeter
Min. Max.
Min.
Inches
Max.
A
B
12.70 14.73
14.23 16.51
0.500 0.580
0.560 0.650
C
D
9.66 10.66
3.54 4.08
0.380 0.420
0.139 0.161
E
F
5.85
2.54
6.85
3.42
0.230 0.420
0.100 0.135
G
H
1.15
-
1.77
6.35
0.045 0.070
0.250
J
K
0.64
4.83
0.89
5.33
0.025 0.035
0.190 0.210
L
M
3.56
0.38
4.82
0.56
0.140 0.190
0.015 0.022
N
Q
2.04
0.64
2.49
1.39
0.080 0.115
0.025 0.055
Dimension TO-263 AA see DSEI 19
© 2000 IXYS All rights reserved
033
Fig. 7 Transient thermal impedance junction to case.
2-2
Similar pages