Proven Reliabilit y E SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS 200V to 7kV at 3W / 8kV at 2W PRODUCT SELECTION TABLE PRODUCT PRODUCTDESCRIPTION DESCRIPTION The E Series is a broad line of small, versatile, component level building blocks in a PCB mount package that provide up to 7kV at 3 Watts continuous output power, (8kV at 2 Watts). This series features low ripple, noise, and EMI/RFI by utilizing a quasi-sinewave oscillator, excellent filtering techniques and a fully enclosed pot core transformer. The output voltage is directly proportional to the input voltage, and is linear from approximately 0.7 volts to maximum input. The isolated output allows for user selectable output polarity. Options include external aluminum box, a dual output option with center-tap pin which, when grounded, provides both positive and negative outputs from one low cost module. Output Voltage vs. Input Voltage 140 t 120 Output Voltage (%) 100 MODEL OUTPUT VOLTAGE*2 OUTPUT CURRENT*1 E02 200V 15mA E02-5 250V 12mA E03 300V 10mA E05 500DV 6.0mA E06 600V 5.0mA E07-5 750V 4.0mA E08 800V 3.7mA E10 1kV 3.0mA E12 1.2kV 2.5mA E15 1.5kV 2.0mA E20 2kV 1.5mA E30 3kV 1.0mA E40 4kV 0.75mA E50 5kV 0.60mA E60 6kV 0.50mA E70 7kV 0.43mA E80 8kV 0.25mA *7 80 Full-load 60 No-load *7 40 20 FEATURES 0 0 10 20 30 40 50 60 70 80 90 100 Input Voltage (%) APPLICATIONS • Electrophoresis • Capacitor Charging • Field Generation • Piezo Devices • Mass Spectrometry • Electrostatic Chuck • Igniter / Spark Module • Sustaining Ion Pumps OPTIONS • Proportional Input/Output • Compact, PCB Mount Package • Low Ripple, Low EMI / RFI • Proven Reliability • Input/Output Isolation • Low Leakage Current • Low Input/Output Coupling Capacitance • No External Components Required • No Minimum Load Required • MTBF: >2 Million Hours per Bellcore TR-332 • UL Certified Encapsulant, Meets 94V-0 Flammability • Mounting Holes • RoHS Compliant • Dual output (Center Tap) Models Available (CT Suffix) • External EMI/RFI Shield (AB Suffix) WWW.XPPOWER.COM 4719BH03 PAGE 1 E SERIES *3 ELECTRICAL SPECIFICATIONS MODEL INPUT VOLTAGE OUTPUT CURRENT RIPPLE*5 REVERSIBLE MODEL OUTPUT VOLTAGE*2 DUAL OUTPUT (CENTER TAP) MODEL*4 OUTPUT VOLTAGE*2 E02/E02CT 0 to 12V 15mA <0.25% E02 0 to 200V E02CT 0 to +/- 100V E02-5/E02-5CT 0 to 12V 12mA <0.75% E02-5 0 to 250V E02-5CT 0 to +/- 125V E03/E03CT 0 to 12V 10mA <1% E03 0 to 300V E03CT 0 to +/- 150V E05/E05CT 0 to 12V 6.0mA <0.1% E05 0 to 500V E05CT 0 to +/- 250V E06/E06CT 0 to 12V 5.0mA <0.1% E06 0 to 600V E06CT 0 to +/- 300V E07-5/E07-5CT 0 to 12V 4.0mA <0.1% E07-5 0 to 750V E07-5CT 0 to +/- 375V E08/E08CT 0 to 12V 3.7mA <0.1% E08 0 to 800V E08CT 0 to +/- 400V E10/E10CT 0 to 12V 3.0mA <0.05% E10 0 to 1kV E10CT 0 to +/- 500V E12/E12CT 0 to 12V 2.5mA <0.05% E12 0 to 1.2kV E12CT 0 to +/- 600V E15/E15CT 0 to 12V 2.0mA <0.05% E15 0 to 1.5kV E15CT 0 to +/- 750V E20/E20CT 0 to 12V 1.5mA <0.25% E20 0 to 2kV E20CT 0 to +/- 1kV E30/E30CT 0 to 15V 1.0mA <0.25% E30 0 to 3kV E30CT 0 to +/- 1.5kV E40/E40CT 0 to 15V 0.75mA <0.5% E40 0 to 4kV E40CT 0 to +/- 2kV E50/E50CT 0 to 15V 0.60mA <0.5% E50 0 to 5kV E50CT 0 to +/- 2.5kV E60/E60CT 0 to 15V 0.50mA <0.5% E60 0 to 6kV E60CT 0 to +/- 3kV E70/E70CT 0 to 15V 0.43mA <1% E70 0 to 7kV E70CT 0 to +/- 3.5kV E80/E80CT 0 to 15V 0.25mA <1.25% E80 0 to 8kV E80CT 0 to +/- 4kV WWW.XPPOWER.COM 4719BH03 PAGE 2 E SERIES *3 ELECTRICAL SPECIFICATIONS PARAMETER VALUE 0 to 12V (E02 to E20) INPUT VOLTAGE 0 to 15V (E30 to E80) TURN-ON VOLTAGE <0.7V <175mA, NO LOAD INPUT CURRENT <400mA, FULL LOAD < +/-3.5kV BIAS (E02 TO E60) ISOLATION < +/-500V BIAS (E70 TO E80) 66uF (E02 to E60) INPUT CAPACITANCE 240uF (E70 to E80) RESPONSE TIME <10mS (Typical) OUTPUT VOLTAGE TOLERANCE +/-5% (Full Load, 100% output voltage) FREQUENCY 30 to 100KHz -10C to +60°C Case (E02 TO E60) OPERATING TEMPERATURE*5 -10C to +50°C Case (E70 TO E80) STORAGE TEMPERATURE -25C to +90°C WWW.XPPOWER.COM 4719BH03 PAGE 3 E SERIES *2 E02-E60 MECHANICAL SPECIFICATIONS RECOMMENDED PCB LAYOUT 2.50 (63.5) TOP VIEW 1.50 (38.1) 1.000 (25.40) 2 0.800 (20.32) 2.100 (53.34) 0 2X ø 0.129 (3.28) CLEARANCE HOLE FOR #4/M3 0.85 (21.6) 0.200 (5.08) 0.20 (5.1) * 0.400 (10.16) 5 3 0.100 (2.54) RECOMMENDED HOLE & PAD O.D. SIZE: ø 0.052 (1.32 ) & ø 0.082 (2.08) *5 PLACES ø 0.031 (0.79) P.C. PINS TYPICAL PARAMETER 0.900 (22.86) 0.35 (8.9) 0.65 (16.5) 0.20 (5.1) 1 4 1.200 (30.48) 1.200 (30.48) OPTIONAL DUAL OUTPUT (CENTER TAP) 0.450 (11.43) 0 0.15 (3.8) TOP VIEW DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS) DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127) PIN # VALUE FUNCTION WEIGHT 3 OZ (85.05 Grams) 1 (+) Input VOLUME <3.2 cubic Inches (52.2 cubic centimeters) 2 (-) Input DIMENSIONS 2.50L (63.5L) x 1.50W (38.1W) x 0.85H (21.6H) 3 (+) Output CASE MATERIAL Diallyl Phthalate (DAP) 4 (-) Output 5 Dual Output/Center Tap (Optional) WWW.XPPOWER.COM 4719BH03 PAGE 4 E SERIES *2 E70-E80 MECHANICAL SPECIFICATIONS RECOMMENDED PCB LAYOUT TOP VIEW 2.50 (63.5) 0.450 (11.43) 0.20 (5.1) PARAMETER 0.800 (20.32) 0.200 (5.08) 4 0.400 (10.16) 5* 3 0.35 (8.9) RECOMMENDED HOLE & PAD O.D. SIZE: Ø 0.052 (1.32) & Ø 0.082 (2.08) *3 PLACES OUTPUT LEADS #22 AWG 30KV SILICONE 6.0" (152.4) MIN. DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS) DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127) PIN/WIRE # VALUE 1 0 2X Ø 0.129 (3.28) CLEARANCE HOLE FOR #4/M3 0.031 (0.79) P.C. PINS TYPICAL 2 OPTIONAL DUAL OUTPUT (CENTER TAP) 1.400 (35.56) 0.85 (21.6) 1.000 (25.40) 0 1.50 (38.1) 1.200 (30.48) 0.65 (16.5) 0.15 (3.8) TOP VIEW FUNCTION WEIGHT 3 OZ (85.05 Grams) 1 (+) Input VOLUME <3.2 cubic Inches (52.2 cubic centimeters) 2 (-) Input DIMENSIONS 2.50L (63.5L) x 1.50W (38.1W) x 0.85H (21.6H) 3 (+) Output CASE MATERIAL Diallyl Phthalate (DAP) 4 (-) Output 5 Dual Output/Center Tap (Optional) WWW.XPPOWER.COM 4719BH03 PAGE 5 E SERIES – ACCESSORY EXTERNAL EMI/RFI SHIELD 4-40 SOLDERABLE GROUNDING STUD 2 PLACES 3.40 (86.36) Ø 0.140 (3.56) THRU 2 PLACES 0.300 (7.62) 0.300 (7.62) 0.80 (20.32) 1.60 (40.64) 0.20 (5.08) 3.000 (76.20) 2.60 (66.04) 0.31 (7.87) HIGH VOLTAGE 0.90 (22.86) 0.40 (10.16) DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS) DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127) PARAMETER VALUE PARAMETER VALUE BOX SIZE See table GROUND Black Anodized Aluminum MATERIAL 0.03 (0.76mm) Aluminum DIMENSIONS WITH TAB 3.4L (86.36L) x 1.6W (40.64W) x 0.9H (22.86H) FINISH Black Anodize 2.6L (66.04L) x 1.6W (40.64W) x 0.9H (22.86H) MOUNTING Two Tabs With Thru-Holes DIMENSIONS WITHOUT TAB SHIELD DESCRIPTION The “AB” Series provides low cost EMI/RFI shielding and rugged mounting for XP EMCO High Voltage DC to DC converters. These five-sided aluminum enclosures feature a durable, non-conductive black anodized finish. The enclosures are manufactured at our own sheet metal fabrication facility, which allows for low cost and stock delivery. Add an “AB” suffix to the model number for a factory-installed enclosure (e.g. E10AB). Contact our sales department by phone, fax or email for immediate attention. WWW.XPPOWER.COM APPLICATION INFORMATION On models with outputs of 3kV or higher, special care must be taken to ensure adequate spacing and insulation between the metal can and the high voltage output. Single sided layout, encapsulants or conformal coating may be required. Case grounding stud must be connected to ground. Case ground is not internally connected to (-) input. 4719BH03 PAGE 6 E SERIES BLOCK DIAGRAM (+) Output (+) In Rectifier & Multiplier Oscillator (-) In Center tap (for Dual output option) (-) Output Transformer OPTION CODE TABLE OPTION POLARITY OPTIONS ORDER CODE MODELS Positive / Negative reversible Blank ALL Dual Output (center tap) option CT ALL Shielding and Mounting Enclosure AB ALL HOW TO ORDER PART NUMBER SELECTOR: Model Number: E10CTAB Model Output Voltage (See table) Shielding & Mounting Enclosure (Optional) Center Tap (for dual output option) EXAMPLE: E10CTAB (E-Model, 10-Output Voltage, CT-Center Tap, AB-Shielding & Mounting Enclosure) * Notes: 1. At maximum rated output voltage. 2. Output voltage is load dependent. Under light or no load conditions, reduce input voltage so maximum rated output voltage is not exceeded. 3. Specifications after 30 minute warm up, full load, at 25C unless otherwise indicated. 4. For dual output units [CT option], the negative output voltage will be ~10% larger than the positive output voltage with respect to the center tap pin. 5. Ripple Specifications for dual output units applies to the voltage between the positive and negative output terminals. 6. Proper thermal management techniques are required to maintain safe case temperature at maximum power output. 7. This unit has flying leads on the output and clearance holes for mounting. XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details. WWW.XPPOWER.COM 4719BH03 PAGE 7