Omron E32-T16JR Fiber sensors best selection catalog Datasheet

CSM_E32series_DS_E_10_1
Fiber Sensors
Best Selection Catalog
OMRON's Fiber Sensors continue to support
an increasing range of applications.
This catalog brings you the latest information on our Fiber Units.
E32-series Fiber Units
Amplifier Units
E3X-DA-S/-MDA Series
E3X-NA Series
Standard Models
P6
First, Our Standard Lineup
These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces
and positioning.
A Wide Variety of Shapes for
Adapting to Different Installation
Locations
Choose the model that suits the installation space from a
wide variety of shapes and sizes.
Space Savings and Simple Mounting
Flat Models
Flat models that allow simple
screw mounting and
straightforward wiring have been
added to the lineup. Using these
models eliminates the problem
of fibers getting caught on
surrounding objects.
Flat model
Detect Workpieces in Tight Spaces
Custom-produced Sleeves
Right angle
Screw-shaped
Cylindrical
Flat
Equipped with sleeve
Models with sleeves allow
detection in tight spaces. We will
perform the time-consuming
task of fashioning the sleeve,
with a length and bends to suit
the space (except for ultrafine
sleeves).
Models with sleeves
Flexible, Pliable Fiber
That Can Be Handled Like Wire
We have developed a broad range of fibers to meet a wide
variety of needs. Multicore (flexible) fiber is a new type of
standard fiber that can be used like wire without worrying
about the bending radius. We have also produced fiber that
will not break when used in moving parts and fiber that is
not degraded by contact with oil.
Conventional fiber
Flexible fiber
You will certainly appreciate the ease of use that flexible fiber ensures.
Length Can Be Specified in 1-m Units
Saving Energy and Work
We will produce fiber of the required length (in meter
units). For large-scale installations, specifications of up
to 20 m can be handled. (Specifications of 0.3 m and
0.5 m are also possible.)
P10
Detection with Increased Reliability
Special-beam Models
A variety of heads incorporating the latest optical technology makes it possible to solve common problems
related to detection and to increase reliability.
Resistant to dust and dirt
Capable of detecting small workpieces
Resistant to workpiece vibration
Use these models to handle unstable detection
conditions.
Environment-resistive Models
Area-sensing models
E32-T16J
Small-spot models
E32-C42+
E39-F3A
Limited-reflective
models
E32-L24L
High-power models
E32-T17L
High Resistance to External
Conditions with Fiber
P14
We have developed model variations for adapting to a variety of environmental conditions.
These models enable detection in high-temperature environments and vacuums.
High-temperature environments
Environments subject to the splattering of chemicals
Vacuums
Use these models to handle applications in special
environments.
Heat-resistant models
Chemical-resistant models
Fiber Units for the Food-packaging,
Semiconductor, and FPD Industries
Application-corresponding Models
P16
These models, which were developed for specific applications, offer top-quality detection performance.
Label detection
Liquid-level detection
Alignment and mapping of glass substrates
Wafer mapping
Use these models for specific applications.
Label-detection models
Alignment-check models
Liquid-level detection models
E32-G14
E32-L16
E32-D36T
Page Reference
Type
Standard models
Feature/
applications
Page 6
Special-beam
models
Page 10
Environment
resistant models
Page 14
Applicationcorresponding
models
Page 16
Accessories
---
Variations
Page 8
---
---
---
---
Type
Throughbeam
Page 19
Reflective
Page 26
Throughbeam
Page 22
Reflective
Page 29
Throughbeam
Page 24
Reflective
Page 32
Ratings and
performance
Page 37
Page 38
Page 39
Page 33
(VacuumPage 25 resisitant)
Page 35
Page 39
---
Dimensions
Throughbeam
Page 40
Reflective
Page 48
Throughbeam
Page 43
Reflective
Page 51
Throughbeam
Page 46
Reflective
Page 56
Page 57
Page 47 (Vacuumresisitant)
Page 60
Selection Guide
Fiber Units
We have developed
model variations for
handling a broad
range of applications.
Amplifier Units
Fiber Units
Detection
conditions
Environmental
conditions
Standard environments
Standard Models
Standard
detection
P.6
Environment-resistive Models
Positioning
Level
differences
Special-beam Models
Marks
Positioning
Level
difference
P.10
Small spot
Area sensing Retroreflective
sensing
Application-corresponding Models
corresponding
Workpiece
presence
■ Long-distance sensing, resistance to
dust and dirt
■ Small beam, resistance to rattling
■ Detection of transparent objects
High power
Application-
P.14
■ Workpiece presence
■ Positioning
■ Level differences and marks
Workpiece
presence
Specialbeam
■ High-temperature environments (up to 400ºC)
■ Environments subject to scattering of chemicals and oil
■ Vacuum environments
Special environments
P.16
■ Labels
■ Liquid level
■ Alignment and mapping of glass substrates
■ Wafer mapping
Labels
Liquid level
Alignment
Mapping
Amplifier Units
Type
Digital
Manual
Appearance
Response
time
2-channel
models
100 μs, 1 ms, or 4 ms
48 µs, 1 ms, or 4 ms
(2-output models: 80 µs, 1 ms, or 4 ms)
Light source Red, green, blue, or infrared LED
Function
Models
4
200 µs
(high-speed models: 20 µs)
Red or green LED
Dual display (including digital, bar, percent, and hold display functions)
Threshold adjustment performed manually or by teaching
OFF-delay, ON-delay, one-shot timer (adjustable from 1 ms to 5 s)
LED bar display (5 levels)
8-turn sensitivity adjuster
OFF delay timer (fixed at 40 ms)
Advanced-function models are
available (2-output/input models).
Water-resistant models are available.
E3X-DA@-S
E3X-DA@TW-S (2-output model)
E3X-DA@RM-S (input model)
E3X-MDA@
E3X-NA@
E3X-NA@F (high-speed model)
E3X-NA@V (water-resistant model)
CONTENTS
■ Selection Guide
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P4
■ Overview of Features, Applications, and Variations
Standard Models
Flexible (New Standard) . . . . . . . . . . . . . . . . . . P6
Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P6
Break-resistant . . . . . . . . . . . . . . . . . . . . . . . . . . . P6
Fluorine Coating . . . . . . . . . . . . . . . . . . . . . . . . . . P7
Special-beam Models
Long Distance, High Power . . . . . . . . . . . . . . P10
Ultracompact, Ultrafine Sleeve . . . . . . . . . . . . . . P10
Coaxial, Small Spot . . . . . . . . . . . . . . . . . . . . . . . P11
Fine Beam (Narrow Vision Field) . . . . . . . . . . . . P12
Area Sensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . P12
Retroreflective . . . . . . . . . . . . . . . . . . . . . . . . . . . P13
Limited-reflective . . . . . . . . . . . . . . . . . . . . . . . . . P13
Environment-resistive Models
Heat-resistant . . . . . . . . . . . . . . . . . . . . . . . . . . P14
Chemical-resistant. . . . . . . . . . . . . . . . . . . . . . . . P14
Vacuum-resistant . . . . . . . . . . . . . . . . . . . . . . . . P15
Application-corresponding Models
Label Detection. . . . . . . . . . . . . . . . . . . . . . . . . P16
Liquid-level Detection . . . . . . . . . . . . . . . . . . . . . P16
Glass-substrate Alignment . . . . . . . . . . . . . . . . . P17
Glass-substrate Mapping . . . . . . . . . . . . . . . . . . P17
Water Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . P18
■ Ordering Information
Through-beam Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P19
Fiber Units with Reflective Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P26
Application-corresponding Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P33
■ Ratings/Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P37
■ Dimensions
Through-beam Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P40
Fiber Units with Reflective Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P48
Application-corresponding Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P57
■ Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P63
5
Features/Applications
Standard Models
R
Flexible (New Standard)
• Perform wiring without worrying about the bending
radius.
• Choose the model to suit the installation space from
a variety of shapes.
Flexible fiber
Conventional fiber
■ Feature: Multicore (Flexible) Fibers
Cores
Cladding
A large number of ultrafine cores are all surrounded by
cladding. As a result, the fiber is flexible and can be bent
without significantly reducing the light intensity. This
helps solve problems, such as fiber being broken by getting caught on other objects.
■ Ratings/Characteristics
Fewer problems
Light intensity affected by bends in fiber
Fiber broken by getting caught on surrounding objects
Min. sensing ob0.005-mm dia.
ject
Min. bending ra1 mm
dius
Ambient temper−40°C to 70°C (no icing or condensation)
ature range
Fiber material
Plastic
Standard
■ Feature: Flat Models
• Choose the model to suit the installation space
from a variety of shapes.
• New flat models allow space savings and simple
installation.
Flat models, which allow simple attachment and wiring,
have been added to the lineup. Choose the model to suit
the installation space from 3 sensing directions and 2
sizes, standard and small.
■ Ratings/Characteristics
Min. sensing object
Min. bending radius
Ambient temperature range
Screw-shaped
Cylindrical
Flat
Equipped with sleeve
Fiber material
0.005-mm dia.
10 or 25 mm*
−40°C to 70°C (no icing or condensation)
Plastic
*Depends on the fiber diameter.
B
Break-resistant
• Bundle-fiber models can be used for moving parts.
• Capable of withstanding at least one million repeated bends (in typical applications).
■ Feature: Bundle Fibers
The Fiber Units contain a large number of independent
fine fibers, ensuring a high degree of flexibility.
■ Ratings/Characteristics
Min. sensing object
Min. bending radius
Ambient temperature range
Fiber material
6
0.005-mm dia.
4 mm (withstands repeated bending)
−40°C to 70°C (no icing or condensation)
Plastic
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Standard Models
U
Fluorine Coating
• Fiber degradation due to oil is prevented using a fluo- ■ Feature: Fluorine Coating
roresin coating.
(Cross section)
• Free cutting is possible with cutter provided.
Fluororesin coating
Fluororesin is used as the sheath material to prevent fiber degradation resulting from oil adhesion.
Oil is blocked!
Note: The tip of the head is not chemical-resistant.
■ Ratings/Characteristics
■Applicable Models
Standard models
Flexible Break-resistant Models
Min. bending radius
4 mm
Ambient temperature range
−40°C to 70°C (with no icing or condensation)
Fiber material
Plastic
■ Fiber Length vs. Sensing Distance
Through-beam Fiber Units
Fiber Units with Reflective Sensors
(Fiber length of 2 m corresponds to (Fiber length of 2 m corresponds to
100%.)
100%.)
■Model Number Used for Ordering
Standard model number + Fiber length
Fiber length: 0.3 m, 0.5 m, or any length from
1 to 20 m (in 1-m units)
Sensing distance (%)
Fiber Length
0.005-mm dia.
This customization/delivery service applies to standard models. It is
aimed at reducing industrial waste and simplifying the installation
procedure.
Sensing distance (%)
(Fiber Length, Sleeve
Fiber Customization Service Length, and Bends)
Min. sensing object
100
80
60
100
80
60
40
40
20
20
0
2
5
10
15
20
0
2
5
10
Fiber length (m)
Sleeve Length and Bends
■Applicable Models
E32-TC200B/E32-TC200F
E32-DC200B/E32-DC200F
The E32-DC200B cannot be bent.
15
20
Fiber length (m)
■ Model Number Used When Changing Only the Sleeve Length
L
Model: E32- *1 C200 *2 -S*3
■ Model Number Used When Changing the Sleeve Length and Bends
Total length
L1
R
Total length
L2
R
Model Numbers Incorporating the Bending Radius, R, and Dimensions L1 and L2
Specifying L1 Only
(Units: mm) Specifying L2 Only
(Units: mm)
Bending
radius
R5
R7.5
R10
R12.5
L1 (±1)
Model number
10
E32- *1 C200 *2 -S *3 A1
15
E32- *1 C200 *2 -S *3 A2
12.5
E32- *1 C200 *2 -S *3 B1
17.5
E32- *1 C200 *2 -S *3 B2
15
E32- *1 C200 *2 -S *3 C1
20
E32- *1 C200 *2 -S *3 C2
17.5
E32- *1 C200 *2 -S *3 D1
22.5
E32- *1 C200 *2 -S *3 D2
Bending
radius
R5
R7.5
R10
R12.5
L2 (±1)
Model number
5
E32- *1 C200 *2 -S *3 A3
10
E32- *1 C200 *2 -S *3 A4
7.5
E32- *1 C200 *2 -S *3 B3
17.5
E32- *1 C200 *2 -S *3 B4
10
E32- *1 C200 *2 -S *3 C3
20
E32- *1 C200 *2 -S *3 C4
12.5
E32- *1 C200 *2 -S *3 D3
22.5
E32- *1 C200 *2 -S *3 D4
*1: Insert "T" for Through-beam Fiber Units and "D" for Fiber Units with Reflective Sensors.
*2: Insert the "B" or "F" that appears at the end of the original model number.
*3: Insert "50" if the total length is 50 mm. The total length must not exceed 120 mm.
7
Features/Applications
Standard Models
Sensing distance (mm)
(See note 1.)
Model
Overview of Model Variations
Through-beam Fiber Units
Type Flexible (New Standard)
(See note 2.)
R
Standard
Break-resistant
Fluorine coating
U
B
(Cross section)
Fluororesin coating
Shape of head
Flexible and pliable
Withstands repeated
bending
[For dimensions, refer to page 40.]
M4
Cable protected against
oil
530
E32-T11N
Screw-shaped
M4
530
760
680
680
(top-view)
E32-T11R
M3
E32-TC200
130
E32-T21R
(with sleeve)
M4
(1.2-dia.
sleeve)
M3
(0.9-dia.
sleeve)
Cylindrical
220
E32-TC200E
530
E32-TC200BR
E32-T11U
200
E32-T21
760
E32-TC200B
130
E32-TC200FR
3 dia.
E32-T11
220
E32-TC200F
530
760
680
(top-view)
E32-T12R
1.5 dia.
E32-T12
130
E32-T222R
3 dia.
E32-T12B
220
E32-T222
210
200
E32-T22B
460
(side-view)
E32-T14LR
1 dia.
E32-T14L
50
E32-T24R
Flat
15 × 8 × 3
130
E32-T24
530
760
680
(top-view)
E32-T15XR
12 × 7 × 2
E32-T15X
130
E32-T25XR
15 × 8 × 3
E32-T15XB
220
E32-T25X
210
150
E32-T25XB
460
(side-view)
E32-T15YR
12 × 7 × 2
E32-T15Y
50
E32-T25YR
15 × 8 × 3
130
E32-T25Y
210
460
(flat-view)
E32-T15ZR
12 × 7 × 2
E32-T15Z
50
E32-T25ZR
130
E32-T25Z
Note 1. The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
2. These symbols are defined as follows.
: Bendable fiber,
R : Flexible fiber,
B
U : Fluorine-coated fiber.
8
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Standard Models
Sensing distance (mm)
(See note 1)
Model
Overview of Model Variations
Fiber Units with Reflective Sensors
Type Flexible (New Standard)
(See note 2.)
R
Standard
Break-resistant
Fluorine coating
U
B
(Cross section)
Fluororesin coating
Flexible and pliable
Shape of head
Withstands repeated
bending
[For dimensions, refer to page 40.]
M6
Cable protected against
oil
170
E32-D11N
M6
170
E32-C11N
M3
25
E32-C31N
Screw-shaped
M6
170
300
170
170
(top-view)
E32-D11R
M3
E32-DC200
30
E32-D21R
(with sleeve)
Cylindrical
M6
(2.5-dia.
sleeve)
M3
(1.2-dia.
sleeve)
3 dia.
E32-D11
80
E32-DC200E
170
E32-DC200BR
E32-D11U
30
E32-D21
300
E32-DC200B
30
E32-DC200FR
80
E32-DC200F
170
230
70
(top-view)
E32-D12R
3 dia.
(1.5 dia.)
E32-D12
30
E32-D22R
6 dia.
E32-D221B
80
E32-D22
45
30
E32-D22B
110
(side-view)
E32-D14LR
2 dia.
E32-D14L
15
E32-D24R
Flat
15 × 10 × 3
30
E32-D24
170
300
170
(top-view)
E32-D15XR
12 × 7 × 2
E32-D15X
30
E32-D25X
15 × 10 × 3
E32-D15XB
80
E32-D25X
40
50
E32-D25XB
100
(side-view)
E32-D15YR
12 × 8 × 2
E32-D15Y
8
E32-D25YR
15 × 10 × 3
20
E32-D25Y
40
100
(flat-view)
E32-D15ZR
12 × 8 × 2
E32-D15Z
8
E32-D25ZR
20
E32-D25Z
Note 1. The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
2. These symbols are defined as follows.
: Bendable fiber,
R : Flexible fiber,
B
U : Fluorine-coated fiber.
9
Features/Applications
Special-beam Models
Long Distance, High Power
• Powerful beam reduces influence of dust and dirt.
• Long sensing distance enables use in large-scale
installations.
■ Applications
Detecting parts inside (trans- Detecting workpieces in
lucent) containers
coating processes
E32-T11L
E32-T17L
■ Ratings/Characteristics
Ambient tempera−40°C to 70°C (no icing or condensation)
ture range
E32-T14
Fiber material
Plastic
■ Overview of Model Variations
Refle- Through-beam
ctive
Type
Features
Shape, sensing distance (mm)*
20,000
Equipped with large lens
3,400
Side-view, screw mounting
E32-T14
1,330
M4 screw
Model number
E32-T17L
E32-T11L
Equipped with large lens
700
E32-D16
M6 screw
400
E32-D11L
Ultracompact, Ultrafine Sleeve
• Ultracompact head can be installed in tight spaces.
• Ultrafine sleeve ensures reliable detection of small
objects, such as electronic components.
■ Applications
Alignment
inspections
Detection of terminals
E32-D33
1 dia.
E32-T33-S5
3 dia.
E32-T223R
■ Ratings/Characteristics
0.22
dia.
3 dia.
0.5 dia.
E32-T334-S5
Min. sensing object
0.005-mm dia.
Ambient temperature
range
−40°C to 70°C (no icing or condensation)
Material
Plastic
E32-D33
■ Overview of Model Variations
Refle- Through-beam
ctive
Type
Features
Shape, sensing distance (mm)*
130
E32-T223R
0.5-dia. sleeve (0.25-dia. opening)
44
E32-T33-S5
0.22-dia. sleeve (0.1-dia. opening)
5
E32-T334-S5
1-dia. cylinder
0.8-dia. sleeve
16
E32-D33
0.5-dia. sleeve
3
E32-D331
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
10
Model number
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Special-beam Models
Coaxial, Small Spot
• Small spot diameter (0.1 mm min. in diameter) enables ■ Applications
the reliable detection of small workpieces.
Detecting of CDs
• Use of red light ensures easy visual recognition and
simple positioning.
E32-C31+
E39-F3C
■ Ratings/Characteristics
E32-C42+
E39-F3A
Min. sensing object
0.005-mm dia.
Ambient temperature range
−40°C to 70°C (no icing or condensation)
Fiber material
Plastic
■ Overview of Model Variations
Coaxial, reflective
Type
Features
Shape, sensing distance (mm)*
Model number
Coaxial, M6 screw
300
E32-CC200
Coaxial, 3-dia. cylinder
150
E32-D32L
Small spot
0.1-dia. spot at a distance of 7 mm
E32-C41+
E39-F3A-5
Small variable spot
Spot diameter variable in the
range 0.1 to 0.6 mm at distances
in the range 6 to 15 mm
E32-C42+
E39-F3A
Long distance, small spot
0.5-dia. spot at 17 mm
E32-C31+
E39-F3B
Long distance, parallel light
Spot diameter of 4 mm max. at
E32-C31+
distances in the range 0 to 20 mm E39-F3C
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
11 mm
6 mm
7 mm
17 mm
0.1 mm dia. spot
E32-C41+
E39-F3A-5
15 mm
Variable from
0.1 to 0.6 dia.
E32-C42+
E39-F3A
20 mm
4 mm dia.
0.5 mm dia.
E32-C31+
E39-F3B
E32-C31+
E39-F3C
11
Features/Applications
Special-beam Models
Fine Beam (Narrow Vision Field)
• Fine beam reduces unwanted light in surrounding area.
• Powerful beam allows use in applications requiring a
long sensing distance.
Approx.
60°
■ Applications
Alignment inspection
of orientation flats
Approx. 4°
E32-T22S
■ Ratings/Characteristics
1300 mm
E32-T24S
Min. bending radius
10 mm
Ambient temperature range
−40°C to 70°C (no icing or condensation)
Fiber material
Plastic
■ Overview of Model Variations
Through-beam
Type
Features
Shape, sensing distance (mm)*
Model number
Top view
1,900 E32-T22S
Side view
1,300 E32-T24S
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
Area Sensing
• These Fiber Units ensure greater reliability with the ■ Applications
detection of position inconsistencies in passing workpieces and the presence of workpieces with holes.
Detecting passage of
• Wide sensing bands of 11 and 30 mm (through-beam
candies
models) enable the detection of large position inconsistencies.
11 mm
Detecting chips on film
E32-T16WR
E32-T16PR
■ Ratings/Characteristics
30 mm
E32-T16WR
Ambient temperature range
−40°C to 70°C (no icing or condensation)
E32-T16W@ only: −25°C to 55°C
Fiber material
Plastic
E32-D36P1
■ Overview of Model Variations
Reflective
Through-beam
Type
Features
Shape, sensing distance (mm)*
Model number
Sensing width: 11 mm
840
Sensing width: 11 mm
Flat-view
750 E32-T16JR
Sensing width: 30 mm
1,300 E32-T16WR
Beam width: 11 mm
E32-T16PR
150 E32-D36P1
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
12
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Special-beam Models
Retroreflective
• The return optical path ensures that more light is
interrupted by transparent workpieces than with
through-beam models.
• Equipped with MSR function to eliminate light
reflected directly from the workpiece.
■ Applications
Detecting
translucent
medicine
E32-R21
■ Ratings/Characteristics
Ambient
temperature
range
E32-R21: −40°C to 70°C
E32-R16: −25°C to 55°C
(with no icing or condensation)
Fiber material Plastic
E32-R16
■ Overview of Model Variations
Retroreflective
Type
Features
Shape, sensing distance (mm)*
MSR function, M6 screw
Model number
250 E32-R21
MSR function, screw mounting, long
distance
1,500 E32-R16
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
Limited-reflective
• Limited-reflective models eliminate light reflected
from distant objects.
• Small level differences can be reliably detected.
• The optical-axis direction can be selected according
to the installation space.
■ Applications
Detecting connector
pins
Detecting wafers
(glass substrates)
E32-L25L
Non-detection range
Detection range
E32-L24L
■ Ratings/Characteristics
E32-L24L
Min. sensing
object
0.005-mm dia.
Fiber material
Plastic
200°C models only: Glass
■ Overview of Model Variations
Limited-reflective
Type
Features
Ultracompact, flat-view
Ideal for checking stocks of glass substrates
Heat-resistant up to 105°C,
top-view
Shape, sensing distance (mm)*
Model number
0 to 4 E32-L24S
5.4 to 9
E32-L25L
(center: 7.2)
Wide sensing range,
flat-view
0 to 15 E32-A10
Heat-resistant up to 200°C,
flat-view
4 to 10 E32-L86
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
13
Features/Applications
Environment-resistant Models
Heat-resistant
• These Fiber Units can be used for various applications in temperatures up to 400°C.
■ Applications
Detecting wafers in
high-temperature environments
E32-T61-S
■ Ratings/Characteristics
200°C and higher models
E32-T81R
All other models
E32-D81R
150°C models
Min. bending
radius
35 mm
10 mm
25 mm
Glass (fluoFiber material (fluororesin coating) roresin coating)
Plastic
E32-T84S-S
Glass (SUS spiral coating)
■ Overview of Model Variations
Refle- Through-beam
ctive*2
Type
Ambient temperature range
Shape, sensing distance (mm)*1
Features
−40°C to 150°C M4 screw
760
−40°C to 200°C L-shaped, long distance
Model number
E32-T51
1,300
E32-T84S-S
−60°C to 350°C M4 screw
450
E32-T61-S
−60°C to 350°C M6 screw
90
E32-D61-S
−40°C to 400°C M6 screw, with sleeve
60
E32-D73-S
*1 The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
*2 Order the Fiber Unit based on the Amplifier Unit. Use the E32-D@-S if the E3X-DA@-S, E3X-MDA@, or E3X-DAC@-S is used.
Use the E32-D@ if any other Amplifier is used.
Chemical-resistant
• Built-in lens and high-power beam reduce the influence of dirt and drops of water.
• Round design prevents drops of water sticking to the
head (E32-T11F).
■ Applications
Detecting workpieces in cleaning processes
E32-T12F
■ Ratings/Characteristics
Ambient temperature range
E32-T14F
Fiber material
All other models
E32-T51F
E32-T81F-S
−40°C to 70°C
−40°C to
150°C
−40°C to 200°C
Plastic
(fluororesin coating)
Glass (fluororesin
coating)
■ Overview of Model Variations
Reflective*2 Through-beam
Type
Features
Shape, sensing distance (mm)*
Model number
Water-resistant round head
2,000
E32-T11F
Built-in lens, high power
3,000
E32-T12F
Heat-resistant up to 200°C
Built-in lens, high power
700
95
E32-T81F-S
E32-D12F
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
14
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Environment-resistant Models
Vacuum-resistant
• These models can be used in high-vacuum environ- ■ Applications (Configuration Example)
ments at pressures from 10-5 to 0.1 Pa.
Vacuum chamber
Atmospheric-pressure side
Vacuum side
Lens Unit
E39-F1V
• The 4-channel multi-flange, which has a maximum
leakage rate of 1×10-10 Pa·m3/s, contributes to space
savings.
Fiber Unit on vacuum side (set of 2)
Flange
E32-T51V
E32-VF4 (4 CH)
E32-T54V
E32-VF1 (1 CH)
E32-T84SV
Fiber Units on atmosphericpressure side (set of 2)
E32-T10V
Amplifier Unit
E3X-DA-S
E3X-NA
■ Ratings/Characteristics
120°C models
Min. bending radius
200°C
models
30 mm
Atmosphericpressure side
25 mm
Fiber mate- Glass (fluorores- Glass (SUS
in coating)
spiral coating)
rial
Plastic
■ Overview of Model Variations
Through-beam
Type
Features
Shape, sensing distance (mm)*
Model number
M4 screw, top-view, heat-resistant up
to 120°C, long distance
1,000
L-shaped, heat-resistant up to 120°C
130
E32-T54V
1M
L-shaped, long distance, heat-resistant up to 200°C
480
E32-T84SV
1M
E32-T51V+
E39-F1V
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
Fiber Units on Atmospheric-pressure Side
Appearance
Type
Model number
Common
E32-T10V 2M
Type
Model number
4-channel flange
E32-VF4
1-channel flange
E32-VF1
Flanges
Appearance
■ Ratings/Characteristics
Item
Number of channels
Model
4 channels
1 channels
E32-VF4
E32-VF1
Leakage rate
1×10-10 Pa·m3/s max.
Ambient temperature
range
Operating: −25°C to 55°C
Storage: −25°C to 55°C
Material
Aluminum (A5056)
Flange-seal material
Fluorocarbon rubber (Viton)
Weight (packed state)
Approx. 280 g
Stainless steel (SUS304)
Aluminum (A5056)
Approx. 240 g
15
Features/Application
Application-corresponding Models
Label Detection
• Built-in lens and high-power beam enable the reliable detection of labels through a mounting board.
• These Fiber Units can be washed with hydrogen peroxide,
making them ideal for the food industry.
■ Applications
Detecting labels
■ Ratings/Characteristics
E32-G14
Ambient tempera−40°C to 70°C (no icing or condensation)
ture range
10 mm
E32-G14
Fiber material
Plastic
Degree of protection
IP67
Type
Features
Through-beam
■ Overview of Model Variations
Shape, sensing distance (mm)*
Slot sensor, no adjustment of optical axis
required
Screw mounting, side-view
Model number
10
E32-G14
3,400
E32-T14
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
Liquid-level Detection
■ Operating Principle
• Area sensing is possible with minimal influence from
bubbles and drops of water (E32-A01/A02/D36T).
Tube-mounting
• For safety when disconnections occur, two models
have been developed, a light ON model for liquid presTube
Liquid
Air
ence and a light ON model for liquid absence (E32-A01/
A02).
Tube-mounting model
Liquid-contact model
Liquid-contact model
Air
Liquid
No liquid
present
E32-D36T
E32-D82F1
Liquid
present
The presence/absence of liquid is detected using the
refractive properties of light. More specifically, it utilizes
the fact that the difference in refractive index between
the air and the tip/tube is larger than the difference between the liquid and the tip/tube.
■ Overview of Model Variations
Liquidcontact
Tube-mounting
Type
Features
Shape, sensing distance (mm)*
Model number
Light ON when liquid is present
(ideal for checking lower limits)
Applicable tube: Transparent tube with a
diameter of 3.2, 6.4, or 9.5 mm and a rec- E32-A01
ommended wall thickness of 1 mm
Light ON when liquid is absent
(ideal for checking for overflow)
Applicable tube: Transparent tube with a
diameter in the range 6 to 13 mm and a
recommended wall thickness of 1 mm
No restriction on tube diameter, resistant to bubbles and drops of water
Applicable tube: Transparent tube (no reE32-D36T
striction on diameter)
Heat-resistant up to 200°C, shape preLiquid-contact model
vents liquid buildup
E32-A02
E32-D82F1
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
16
ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì
Application-corresponding Models
Glass-substrate Alignment
• There is little variation of detection position within the ■ Engineering Data (E32-A07/A08/L16-N)
detection range (±0.1 mm max.)
• The different model variations can handle a variety of
Detection-Position Characteristic (Typical Examples)
sensing distances and temperature conditions.
Sensing object: Raw glass
E32-A07
(t = 0.7 mm, rounded edge)
Sensing distance, Y (mm)
25
X
Y
20
15
10
E32-A08
5
E32-L16-N
E32-L16-N
0
2.5
3.0
3.5
4.5
5.0
6.0
■ Overview of Model Variations
Type
Features
Shape, sensing distance (mm)*
Limited-reflective
0 to 15 mm, wide-range sensing
Model number
0 to 15
E32-L16-N
10 to 20
E32-A08
15 to 25
E32-A07E1
E32-A07E2
5 to 18
E32-L66
Long-distance sensing
Heat-resistant up to 300°C
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
Glass-substrate Mapping
200
Rounded
edge
150
Rate of change of digital
light-intensity value (%)
Digital light-intensity value
• These models can reliably detect thin glass-substrate ■ Engineering Data (E32-A09)
end faces (t = 0.5 mm, beveled edge).
Digital Light-intensity Value vs Sensing Distance
Angle Characteristics in Left and Right Directions
(Typical Examples)
(Typical Example)
• Using a large-diameter lens makes it possible to cope
300
100
250
with tilting of the glass substrates.
Beveled
edge
100
50
0
0
10
20
30
40
50
60
70
75
50
25
0
−10 −8
Sensing distance, X (mm)
Sensing object: Raw glass
(t = 0.5 mm, beveled/rounded edge)
X mm
−6
−4
−2
0
2
4
6
8
10
Angle, θ (o)
Sensing object: Raw glass
(t = 0.5 mm, rounded edge)
25 mm
+θ
−θ
Emission side
Reception side
E32-A09
Type
Features
Limited-reflective
■ Overview of Model Variations
Large-diameter lens ensures resistance to tilting
Shape, sensing distance (mm)*
Model number
E32-A09
15 to 38 (center: 25)
Heat-resistant up to 150°C
Heat-resistant up to 300°C
E32-A09H
20 to 30 (center: 25)
E32-A09H2
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
17
Features/Applications
Application-corresponding Models
Wafer Mapping
• Wafers are reliable detected with an ultrafine beam.
• The optical axis is adjusted before delivery to allow
easy installation.
E32-A03
■ Features
Optical axis adjusted
before delivery so
that displacement is
typically within 0.1°. Direction of rotation
Vertical rotation
■ Engineering Data
Rate of change of digital light-intensity
value (%)
E32-A03-1
8-inch Wafer Mapping Characteristic (Typical Examples)
180
Wafer piles can
also be detected
160
140
120
100
80
170 mm
60
40
For
2 wafers
X
Fiber
For
1 wafer
2-wafer pile
0
−10
−9
−8
−7
−6
−5 −4 −3 −2 −1
Distance moved, X (mm)
Fiber
6.35 mm
20
0
1
2
3
Silicon wafer
(t = 0.75 mm)
4
■ Overview of Model Variations
Type
Features
Shape, sensing distance (mm)*
Through-beam
Opening angle: 1.5°
With mounting
flange
E32-A03
890
E32-A03-1
Opening angle: 3° ultraslim
With mounting
flange
Model number
E32-A04
340
E32-A04-1
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
18
Ordering Information
Through-beam Fiber Units Standard models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *2
Dimensions
page
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Sensing distance (mm)
Standard object Min. bend(min. sensing ing radius
object) (mm) *1
(mm)
Features
Model number
40
M4 right angle E32-T11N
40
M4 screw
E32-T11R
3-dia. cylinder
E32-T12R
Flat shape
E32-T15XR
M4
M4
700
40
530
350 (140)
Standard size
3 dia.
40
15 × 8 × 3
1 dia.
(0.005 dia.)
90 (40) ( ): E32-TC200B4R
40
E32-TC200BR
M4 screw, with
E32-TC200B4R
sleeve
M4
1.2 dia.
Min. bending radius of sleeve: 5
3 dia.
3-dia. cylinder,
E32-T14LR
side-view
Flexible (new standard)
40
41
15 × 8 × 3
270
210
130 (50)
41
15 × 8 × 3
Flat shape,
side-view
E32-T15YR
Flat shape,
flat-view
E32-T15ZR
M3 screw
(small)
E32-T21R
2-dia. cylinder
(small)
E32-T22R
1.5-dia. cylinder (small)
E32-T222R
Flat shape
(small)
E32-T25XR
M3 screw
(small), with
sleeve
E32-TC200FR
E32-TC200F4R
1-dia. cylinder
(small),
side-view
E32-T24R
Flat shape
(small),
side-view
E32-T25YR
Flat shape
(small),
flat-view
E32-T25ZR
R
R1
40
M3
40
2 dia.
40
1.5 dia.
160
130
75 (30)
Small size
40
12 × 7 × 2
90 (40) ( ): E32-TC200F4R
0.5 dia.
(0.005 dia.)
40
M3
0.9 dia.
Min. bending radius of sleeve: 5
1 dia.
41
41
12 × 7 × 2
41
12 × 7 × 2
60
50
25 (10)
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
Flexible
Break-resistant
Fluororesin coating
19
Through-beam Fiber Units Standard models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *2
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Dimensions
page
Sensing distance (mm)
Standard object Min. bend(min. sensing ing radius
object) (mm) *1
(mm)
Features
Model number
40
M4 screw
E32-TC200
40
3-dia. cylinder
E32-T12
Flat shape
E32-T15X
M4
M4
1,000
760
500 (200)
40
Standard size
15 × 8 × 3
90 (40) ( ): E32-TC200B4R
M4 screw, with E32-TC200B
sleeve
E32-TC200B4
40
M4
1.2 dia.
Min. bending radius of sleeve: 5
1 dia.
(0.005 dia.)
3 dia.
R25
3-dia. cylinder,
E32-T14L
side-view
40
600
41
15 × 8 × 3
460
300 (120)
41
15 × 8 × 3
Flat shape,
side-view
E32-T15Y
Flat shape,
flat-view
E32-T15Z
Standard
900
40
E32-TC200A
680
450 (180)
M3
M3 screw
(small)
40
E32-TC200E
M3
40
2-dia. cylinder
(small)
E32-T22
1.5-dia. cylinder (small)
E32-T222
Flat shape
(small)
E32-T25X
M3 screw
(small),
with sleeve
E32-TC200F
E32-TC200F4
1-dia. cylinder
(small), sideview
E32-T24
Flat shape
(small), sideview
E32-T25Y
Flat shape
(small),
flat-view
E32-T25Z
2 dia.
40
Small size
1.5 dia.
270
220
125 (50)
40
12 × 7 × 2
90 (40) ( ): E32-TC200F4R
0.5 dia.
(0.005 dia.)
40
M3
0.9 dia.
Min. bending radius of sleeve: 5
1 dia.
41
41
12 × 7 × 2
41
12 × 7 × 2
160
130
75 (30)
R10
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
Flexible
20
Break-resistant
Fluororesin coating
Standard models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *2
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Dimensions
page
Sensing distance (mm)
Min.
Standard object
bending
(min. sensing
radius
object) (mm) *1
(mm)
Standard size
42
Model number
M4 screw
E32-T11
3-dia. cylinder
E32-T12B
Flat shape
E32-T15XB
M3 screw
(small)
E32-T21
2-dia. cylinder
(small)
E32-T221B
1.5-dia. cylinder (small)
E32-T22B
Flat shape
(small)
E32-T25XB
M4 screw,
fluorine coating
E32-T11U
M4
900
42
680
450 (180)
3 dia.
1 dia
(0.005 dia.)
42
Break-resistant
Features
15 × 8 × 3
B
42
Small size
M3
R4
42
2 dia.
240
200
110 (45)
0.5 dia
(0.005 dia.)
42
1.5 dia.
42
Coating
12 × 7 × 2
42
M4
180
150
85 (35)
900
680
450 (180)
1 dia.
(0.005 dia.)
U
R4
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
Flexible
Break-resistant
Fluororesin coating
21
Through-beam Fiber Units Special-beam models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *2
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Dimensions
page
Sensing distance (mm)
43
20,000*3
20,000*3
10,000 (4,000)
40
60
4,000
3,700
2,400
(970)
M14
M4
40
60
4,000*4
4,000*4
2,600 (1,500)
40
60
4,000*4
3,700
2,400 (970)
Min.
Standard object
bending
(min. sensing
radius
object) (mm) *1
(mm)
10 dia.
4 dia. (0.1 dia.)
Long-distance, high-power
R25
Large built-in
lens, M14
screw
E32-T17L
R
M4 right angle
E32-T11N+
E39-F1
R25
M4 screw
E32-TC200+
E39-F1
R
M4 screw,
flexible fiber
E32-T11R+
E39-F1
R1
4,000*4
3,600
2,300 (930)
B
Screw mounting, side-view
E32-T14
M4 screw
E32-T11L
3-dia. cylinder
E32-T12L
R25
M4 screw,
side-view
E32-T11L+
E39-F2
R
M4 screw,
E32-T11R+
side-view, flexE39-F2
ible fiber
R25
43
1,700
1,330
870 (350)
M4
43
M4 screw,
E32-T11+
break-resistant E39-F1
R4
4,000*4
3,400
2,250 (900)
43
Model number
R1
M4
42
60
Features
1.4 dia.
(0.01 dia.)
3 dia.
43
60
M4
40
60
42
60
910
800
500 (180)
520
400
250 (100)
3 dia. (0.1 dia.)
R1
820
B
660
430 (160)
R4
43
M3
43
540
440
250 (100)
0.9 dia.
(0.005 dia.)
M4 screw,
E32-T11+
side-view,
E39-F2
break-resistant
M3 screw
(small)
E32-T21L
2-dia. cylinder
(small)
E32-T22L
R10
2 dia.
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
*3. The optical fiber is 10 m long on each side, so the sensing distance is 20,000 mm.
*4. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Flexible
22
Break-resistant
Fluororesin coating
Special-beam models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *2
Dimensions
page
Ultracompact, thin-sleeve
44
1 dia.
3 dia. 0.5 dia.
44
Sleeve cannot be bent.
3 dia. 0.25 dia.
160
130
75 (30)
Standard object Min. bend(min. sensing ing radius
object) (mm)*1
(mm)
0.5 dia.
(0.005 dia.)
R
Model number
1-dia. cylinder,
E32-T223R
flexible fiber
R1
53
44
25 (10)
0.5-dia.
sleeve; 0.25dia. opening
0.25 dia.
(0.005 dia.)
E32-T33-S5
0.25-dia.
sleeve, 0.125- E32-T333-S5
dia. opening
0.125 dia.
(0.005 dia.)
44
6
5
3 (2)
0.1 dia.
(0.005 dia.)
0.22-dia.
sleeve, 0.1dia. opening
1.7 dia.
(0.1 dia.)
3-dia. cylinder E32-T22S
44
2,500
1,900
1,250 (500)
44
1,750
1,300
870 (350)
3 dia.
R10
E32-T334-S5
R10
3.5 dia.
45
3.5-dia. cylinE32-T24S
der, side-view
2 dia. (0.1 dia.)
1,100
840
560 (220)
R
R1
11
1,500
1,100
750 (300)
45
45
Area-sensing
Features
12
10
6 (4)
Sleeve cannot be bent.
Fine-beam
Sensing distance (mm)
44
Sleeve cannot be bent.
3 dia. 0.22 dia.
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
11
45
1,700
1,300
850 (340)
44
2,300
1,800
1,150 (450)
45
3,700
2,800
1,850 (740)
10
44
750
610
350 (140)
E32-T16P
(0.2 dia.) *3
R
R1
1,300
1,000
650 (260)
30
M3
R10
980
750
480 (190)
44
E32-T16PR
Area width:
11 mm
Area width:
11 mm; sideview
R10
R
(0.3 dia.) *3
R1
R10
(0.6 dia.) *4
R25
2 dia. (0.1 dia)
E32-T16JR
E32-T16J
E32-T16WR
Area width:
30 mm
E32-T16W
Area width:
10 mm; long
E32-T16
distance
Multi-point detection (4E32-M21
head)
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
*3. This is the value for which detection is possible within the sensing area, with the sensing distance set to 300 mm. (The sensing object is stationary.)
*4. This is the value for which detection is possible within the sensing area, with the sensing distance set to give a digital value of 1,000. (The sensing object is stationary.)
23
Through-beam Fiber Units Environment-resistant models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *2
Dimensions
page
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Sensing distance (mm)
1,000
760
500 (200)
46
150°C
*5
M4
46
2 dia.
46
Heat-resistant
M4
M4
200°C
*6
M4
46
60
300
230
150 (60)
360
280
180 (70)
Min.
Standard object
bending
(min. sensing
radius
object) (mm)*1 (mm)
1.5 dia.
(0.1 dia.)
1 dia.
(0.005 dia.)
600
R35
R10
3 dia. (0.1 dia.)
450
300 (120)
4,000*7
4 dia. (0.1 dia.)
3,400
2,200 (900)
46
60
R25
3 dia.
350°C
*6
1,750
1.7 dia.
1,300
(0.1 dia)
870 (350)
46
46
M4
600
46
2,500
2,000
1,300 (520)
46
4,000*7
3,000
2,000 (800)
Chemical-resistant
7.2 dia.
5 dia.
5 dia.
46
46
5 dia.
6 dia.
1 dia.
(0.005 dia.)
450
300 (120)
46
500
400
250 (100)
R4
4 dia. (0.1 dia.)
3 dia. (0.1 dia.)
R40
1,800
4 dia. (0.1 dia.)
1,400
900 (350)
920
700
460 (190)
1 dia.
(0.005 dia.)
R10
Features
Heat-resistant up to
150°C
Heat-resistant up to
150°C; sideview
Heat-resistant up to
200°C
Heat-resistant up to
200°C; sideview
Heat-resistant up to
200°C, long
distance
Heat-resistant up to
200°C; Lshaped; long
distance
Heat-resistant up to
350°C
Fluororesin
cover, round
head
Fluororesin
cover, long
distance
Fluororesin
cover, sideview
Fluororesin
cover, heatresistant up to
150°C *5
Fluororesin
cover, heatresistant up to
200°C *6
Model number
E32-T51
E32-T54
E32-T81R-S
E32-T61-S+
E39-F2
E32-T61-S+
E39-F1
E32-T84S-S
E32-T61-S
E32-T11F
E32-T12F
E32-T14F
E32-T51F
E32-T81F-S
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
*3. This is the value for which detection is possible within the sensing area, with the sensing distance set to 300 mm. (The sensing object is stationary.)
*4. This is the value for which detection is possible within the sensing area, with the sensing distance set to give a digital value of 1,000. (The sensing object is stationary.)
*5. For continuous operation, use the products within a temperature range of−40°C to 130°C.
*6. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details.
*7. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
24
Environment-resistant models
High-resolution mode
Standard mode
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
(
Appearance (mm)
Dimensions
page
Sensing distance (mm)
Standard object
Min. bending
(min. sensing obradius (mm)
ject) (mm) *
47
260
200
130 (50)
1.2 dia. (0.01 dia.)
1,350
1,000
680 (260)
47
47
Vacuum-resistant
Type
M4 screw,
heat-resistant
up to 120°C
M4 screw,
heat-resistant
up to 120°C,
long distance
L-shaped,
heat-resistant
up to 120°C
L-shaped,
heat-resistant
up to 120°C,
long distance
L-shaped,
heat-resistant
up to 200°C,
long distance
4 dia. (0.1 dia.)
R30
47
210
130
100 (35)
1.2 dia. (0.01 dia.)
660
47
47
500
330 (180)
630
47
480
320 (130)
4 dia. (0.1 dia.)
2 dia. (0.1 dia.)
Features
R25
Model number
E32-T51V 1M
E32-T51V 1M+
E39-F1V
E32-T54V 1M
E32-T54V 1M+
E39-F1V
E32-T84SV 1M
* The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to
optimum values.
Flanges
Lens Units
Appearance (mm)
Dimensions
page
47
47
Type
Model
number
4-channel
flange
E32-VF4
1-channel
flange
E32-VF1
Dimensions
page
47
*
Type
Dimensions
page
47
Model number
Type
E39-F1V
Quantity
Remarks
2
Long-distance Lens
Unit
Can be used for the
E32-T51V and the
E32-T54V.
Mounting Brackets
Appearance (mm)
Fiber Units for Atmospheric-pressure Side
Appearance (mm)
Appearance (mm)
Dimensions
page
47
Type
E39-L54V
Quantity
Remarks
2
Can be used for
the E32-T54V.
Amplifier-Flange
E32-T10V 2M
Connection Fiber
Indicates models that allow free cutting.
25
Fiber Units with Reflective Sensors Standard models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *3
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Dimensions page
Sensing distance (mm) *1
(Min. sensing Min. bending
object) (mm) *2 radius (mm)
Features
Model number
48
M6 right angle
E32-D11N
48
M6 screw
E32-D11R
3-dia. cylinder
E32-D12R
48
Flat shape
E32-D15XR
48
M6 screw,
with sleeve
E32-DC200BR
E32-DC200B4R
6-dia. cylinder, sideview
E32-D14LR
Flat shape,
side-view
E32-D15YR
Flat shape,
flat-view
E32-D15ZR
48
M4 screw
(small)
E32-D211R
48
M3 screw
(small)
E32-D21R
3-dia. cylinder (small)
E32-D22R
48
Flat panel
(small)
E32-D25XR
48
M3 screw
(small), with
sleeve
E32-DC200FR
E32-DC200F4R
M6
M6
300
170
120 (50)
48
Standard size
3 dia.
15 × 10 × 3
Sleeve cannot be bent. M6 2.5 dia.
6 dia.
Flexible (new standard)
49
80
45
30 (14)
49
15 × 10 × 3
70
40
26 (12)
49
15 × 10 × 3
(0.005 dia.)
R
R1
M4
M3
48
Small size
3 dia.
50
30
20 (8)
12 × 8 × 3
Min. bending
M3 1.2 dia.
radius of
sleeve: 5
2 dia.
12 × 8 × 2
12 × 8 × 2
49
26
15
10 (4)
49
49
14
8
5 (2)
2-dia. cylinder (small),
side-view
Flat shape
(small),
side-view
Flat shape
(small),
flat-view
E32-D24R
E32-D25YR
E32-D25ZR
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
Flexible
26
Break-resistant
Fluororesin coating
Standard models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *3
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Dimensions
page
Sensing distance (mm) *1
Min.
(Min. sensbending
ing object)
radius
(mm) *2
(mm)
500
48
M6 screw
300
200 (90)
M6
400
230
160 (70)
48
3 dia.
Standard size
Sleeve cannot
be bent.
E32-DC200
Flat shape
E32-D15X
M6 screw,
with sleeve
E32-DC200B
E32-DC200B4
500
90 (40)
( ): E32-DC200B4
Model number
3-dia. cylinder E32-D12
48
15 × 10 × 3
Features
300
200 (90)
48
R25
M6 2.5 dia.
6 dia.
200
110
80 (36)
49
6-dia. cylinder,
E32-D14L
side-view
49
15 × 10 × 3
170
100
65 (30)
49
Standard
15 × 10 × 3
(0.005 dia.)
48
Flat shape,
side-view
E32-D15Y
Flat shape,
flat-view
E32-D15Z
M4 screw
(small)
E32-D211
M3 screw
(small)
E32-DC200E
M4
48
M3
48
3-dia. cylinder
E32-D22
(small)
130
80
50 (22)
3 dia.
Small size
48
12 × 8 × 2
R10
( ): E32-DC200F4
Min. bending radius of sleeve: 5
90 (40)
48
M3 1.2 dia.
2 dia.
12 × 8 × 2
12 × 8 × 2
49
50
30
20 (8)
49
49
35
20
12 (6)
Flat shape
(small)
E32-D25X
M3 screw
(small),
with sleeve
E32-DC200F
E32-DC200F4
2-dia. cylinder
(small),
E32-D24
side-view
Flat shape
(small),
side-view
E32-D25Y
Flat shape
(small),
flat-view
E32-D25Z
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
Flexible
Break-resistant
Fluororesin coating
27
Standard models
Fiber Units with Reflective Sensors
High-resolution mode
Standard mode
(
Appearance (mm) *3
Dimensions page
Sensing distance (mm) *1
Min.
(Min. sensing bending
object) (mm) *2 radius
(mm)
50
170
120 (50)
Model number
M6 screw
E32-D11
50
Flat shape
E32-D15XB
M4 screw
(small)
E32-D21B
3-dia. cylinder
(small)
E32-D221B
M3 screw
(small)
E32-D21
15 × 10 × 3
50
110
70
45 (20)
M4
50
(0.005 dia.)
Small size
B
R4
3 dia.
50
M3
50
50
30
20 (8)
1.5-dia. cylinder
E32-D22B
(small)
1.5 dia.
50
12 × 8 × 2
Coating
Features
300
M6
Break-resistant
Standard size
Type
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
50
M6
85
50
30 (15)
300
170
120 (50)
(0.005 dia.)
U
Flat shape
(small)
E32-D25XB
M6 screw,
fluorine coating
E32-D11U
R4
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
Flexible
28
Break-resistant
Fluororesin coating
Special-beam models
High-resolution mode
Standard mode
(
Long-distance, high-power
Type
Appearance (mm) *3
Dimensions
page
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Sensing distance (mm) *1
40 to 1,000
40 to 700
40 to 450 (40 to 240)
51
---
650
51
R25
400
260 (110)
M6
B
R4
17.5
51
M4
51
210
130
80 (35)
3 dia.
Ultracompact, thin-sleeve
Min.
(Min. sensing bending
object) (mm) *2 radius
(mm)
Features
Model number
Large built-in
lens, screw
mounting
E32-D16
M6 screw
E32-D11L
M4 screw
E32-D21L
3-dia. cylinder
E32-D22L
0.8-dia. sleeve
E32-D33
0.5-dia. sleeve
E32-D331
R10
(0.005 dia.)
51
3 dia. 0.8 dia.
Sleeve cannot be bent.
25
16
10 (4)
R4
51
2 dia. 0.5 dia.
Sleeve cannot be bent.
5
3
2 (0.8)
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
29
Fiber Units with Reflective Sensors Special-beam models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *3
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Dimensions
page
Sensing distance (mm) *1
280
170
160 (50)
52
M6
52
M3
52
M6
3 dia.
R
Coaxial, small-spot
52
M6 screw
500
E32-CC200
300
200 (90)
250
150
100 (45)
3-dia. cylinder E32-D32L
M3 screw
(small)
120
75
50 (22)
(0.005 dia.)
52
60
6 to 15 mm; spot diameter: 0.1 to
0.6 mm
52
60
Spot diameter of 0.5 to
1 mm at distances in the
range 6 to 15 mm
52
60
Spot diameter of 0.1 mm at 7 mm
52
60
Spot diameter of 0.5 mm at
7 mm
52
60
Spot diameter of 0.2 mm at 17 mm
52
60
Spot diameter of 0.5 mm at
17 mm
52
60
Spot diameter of 4 mm max. at distances in the range 0 to 20 mm
Area-sensing
Retroreflective
250
150
100 (45)
53
E39-R3
Reflector
53
E39-R3
Reflector
E32-C31
2-dia. cylinder
E32-D32
(small)
R25
Small spot
(variable)
Small spot
E32-C42+
E39-F3A
E32-D32+
E39-F3A
E32-C41+
E39-F3A-5
E32-C31+
E39-F3A-5
E32-C41+
Long distance, E39-F3B
small spot
E32-C31+
E39-F3B
Long-disE32-C31+
tance sensing,
E39-F3C
parallel light
4-dia. spot
M6
M3 right angle E32-C31N
E32-CC200R
2 dia.
53
Model number
R4
250
150
100 (45)
52
M3
Features
M6 right angle E32-C11N
40
25
23 (7)
52
52
Min.
(Min. sensbending
ing object)
radius
(mm) *2
(mm)
(0.005 dia.)
B
Beam width:
11 mm
E32-D36P1
E32-R21+
E39-R3
(Attached)
R4
10 to 250
10 to 250
10 to 250 (10 to 250)
150 to 1,500
150 to 1,500
150 to 1,500
(150 to 1,500)
(0.1 dia.)
R10
M6 screw
(0.2 dia.)
R25
Screw mount- E32-R16+
ing, long dis- E39-R1
(Attached)
tance
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
Flexible
30
Break-resistant
Fluororesin coating
Special-beam models
High-resolution mode
Standard mode
(
Type
Appearance (mm) *3
Dimensions
page
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Sensing distance (mm) *1
Min.
(Min. sensing bending
object) (mm) *2 radius
(mm)
54
Convergent-reflective
54
3.3
3.3
3.3 (3.3)
R25
Features
Model number
Small level differences, high
E32-L25
power, side-view
Small level differences, topview
E32-L25A
Ultracompact,
flat-view
E32-L24S
Heat resistant
up to 105°C *4,
top-view
E32-L24L
E32-L25L
54
0 to 4
0 to 4
0 to 4 (0 to 4)
54
2 to 6 (center: 4)
2 to 6 (center: 4)
2 to 6 (2 to 6) (center: 4)
54
5.4 to 9 (center: 7.2)
5.4 to 9 (center: 7.2)
5.4 to 9 (5.4 to 9) (center: 7.2)
Heat resistant
up to 105°C *4,
top-view
55
4 to 10
4 to 10
4 to 10 (4 to 10)
Heat resistant
up to 200°C, flat- E32-L86
view
55
1 to 5
1 to 5
1 to 5
55
0 to 8
0 to 8
0 to 6
0 to 4
(0.005 dia.)
R10
Soda glass
with reflection
factor of 7%
R25
Heat resistant
up to 300°C
E32-L64
Ideal for detecting glass stock.
E32-A10
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
*4. For continuous operation, use the products within a temperature range of −40°C to 90°C.
31
Environment-resistant models
Fiber Units with Reflective Sensors
High-resolution mode
Standard mode
(
Heat-resistant
Type
Appearance (mm) *3
150°C
*4
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Dimensions
page
56
M6
200°C
*5
Sensing distance (mm) *1
Min.
(Min. sensing bending
object) (mm) *2 radius
(mm)
400
230
160 (72)
56
M6
350°C
*5
56
150
90
60 (27)
Heat resistant
up to 150°C
E32-D51
R10
Heat resistant
up to 200°C
E32-D81R-S
E32-D81R*6
Heat resistant
up to 350°C
E32-D61-S
E32-D61*6
Heat resistant
up to 400°C,
with sleeve
E32-D73-S
E32-D73*6
Fluororesin
cover, long
distance
E32-D12F
Fluororesin
cover, sideview
E32-D14F
(0.005 dia.)
M6
Chemical-resistant
M4
1.25 dia.
Min. bending radius
of sleeve: 10
56
56
6 dia.
100
60
40 (18)
160
95
65 (30)
(0.005 dia.)
7 dia.
56
70
40
30 (10)
Model number
R35
R25
400°C
*5
Features
R40
*1. The sensing distances are for white paper.
*2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*3.
Indicates models that allow free cutting.
*4. For continuous operation, use the products within a temperature range of −40°C to 90°C.
*5. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details.
*6. Order the Fiber Unit based on the Amplifier Unit. Use the E32-D@-S if the E3X-DA@-S, E3X-MDA@, or E3X-DAC@-S is used. Use the E32-D@ if any other Amplifier
is used.
Flexible
32
Break-resistant
Fluororesin coating
Ordering Information
Application-corresponding Fiber Units
High-resolution mode
Standard mode
(
Glass-substrate-alignment
Liquid-level detection
Label-detection
Type
Appearance (mm) *2
Dimensions
page
57
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Sensing distance (mm)
Standard object Min. bend(min. sensing ing radius
object) (mm)*1
(mm)
Model number
Slot sensor (no
adjustment of op- E32-G14
tical axis required)
10
10
10 (10)
4 dia. (0.1 dia.)
R25
4,500
3,400
2,250 (900)
43
Features
57
Applicable tube: Transparent tube with a diameter
in the range 8 to 10 mm and a recommended wall
thickness of 1 mm
57
Applicable tube: Transparent tube (no restriction on
diameter)
58
Applicable tube: Transparent tube with a diameter
of 3.2, 6.4, or 9.5 mm and a recommended wall
thickness of 1 mm
58
Applicable tube: Transparent tube with a diameter
in the range 6 to 13 mm and a recommended wall
thickness of 1 mm
58
Liquid-contact models
54
0 to 15
0 to 15
0 to 15 (0 to 12)
R10
Screw mounting,
side-view
E32-T14
Compact
E32-L25T
No restriction on
tube diameter, reE32-D36T
sistant to bubbles
and drops of water
R4
R40
Light ON when fluid
is present, resistant
E32-A01
to bubbles and
drops of water
Light ON when fluid
is not present, reE32-A02
sistant to bubbles
and drops of water
Heat resistant up
to 200°C,
fluororesin cover
E32-D82F1
E32-D82F2
E32-L16-N
Variation of detection position within E32-A08
the detection
range: 0.1 mm
E32-A07E1
*5
E32-A07E2
*5
58
10 to 20
10 to 20
10 to 20 (-)
58
15 to 25
15 to 25
10 to 20 (-)
58
5 to 18
5 to 18
5 to 16 (-)
Heat resistant up
to 300°C *3, *4
E32-L66
54
10 to 20
10 to 20
10 to 20
Heat resistant up
to 300°C
E32-A08H2
Soda glass
with reflection
factor of 7%
R25
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
*3. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details.
*4. These values are based on the assumption that there are no repeated sudden changes in temperature.
*5. The characteristics for sensing object incline are different between the Attachments with model numbers ending in "E1" and "E2."
Refer to page 52 for installation precautions.
33
Application-corresponding Fiber Units
High-resolution mode
Standard mode
(
Appearance (mm) *2
Glass-substrate-mapping
Type
Dimensions
page
59
59
59
3 dia.
High-speed mode
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Super-high-speed mode)
Sensing distance (mm)
15 to 38 (center: 25)
15 to 38 (center: 25)
15 to 38 (center: 25)
(-)
Edge of soda
glass with reflection factor
of 7%
(t = 0.5 mm,
rounded edge)
20 to 30 (center: 25)
20 to 30 (center: 25)
20 to 30 (center: 25)
(-)
59
1,150
890
600 (250)
3 dia.
59
Wafer-mapping
Min.
Standard object
bending
(min. sensing
radius
object) (mm)*1
(mm)
44
Resistant to tilting
E32-A09
R35
Heat resistant up to
150°C *3
E32-A09H
R25
Heat resistant up to
300°C *4, *5
E32-A09H2
R
Opening angle: 1.5°;
optical axis adjusted E32-A03
before delivery
R1
Opening angle: 1.5°;
with mounting
flange; optical axis E32-A03-1
adjusted before delivery
2 dia. (0.1 dia.)
Long distance;
opening angle: 4°
R10
2 dia.
59
460
340
225 (100)
2 dia.
59
1.2 dia.
(0.1 dia.)
Model
number
R25
1,750
1,300
870 (350)
3.5 dia.
Features
E32-T24S
Ultraslim (t = 2 mm);
opening angle: 3°;
E32-A04
optical axis adjusted
before delivery
Ultraslim (t = 2 mm);
opening angle: 3°;
with mounting
E32-A04-1
flange; optical axis
adjusted before delivery
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2.
Indicates models that allow free cutting.
*3. For continuous operation, use the products within a temperature range of −40°C to 130°C.
*4. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details.
*5. These values are based on the assumption that there are no repeated sudden changes in temperature.
Flexible
34
Break-resistant
Fluororesin coating
Accessories
Lens Units
*When used in combination with the E3X-DA-S Amplifier Unit (general-purpose).
Sensing distance (mm)
Long-distance Lens Units
Side-view Units
Reflection Units
Through-beam Lens Units
Type
Appearance
Dimensions
page
60
Applicable
Fiber Units
4,000*2
3,200
2,100
840
E32-TC200
4,000*2
4,000*2
2,600
1,500
E32-T11R
4,000*2
3,700
2,400
970
E32-T11
4,000*2
3,600
2,300
930
E32-T11U
4,000*2
3,600
2,300
930
2,650
2,100
1,300
520
4,000*2
3,400
2,200
900
E32-T11L
910
800
500
180
E32-TC200
840
700
450
160
E32-T11R
520
400
250
100
E32-T11
820
660
430
160
E32-T11U
820
660
430
160
E32-T81R-S
360
280
180
70
E32-T61-S
600
450
300
120
E32-T61-S
60
E32-T11L
E32-TC200
E32-T11R
E32-T11
E32-T11U
E32-T81R-S
E32-T61-S
E32-C42
60
Small-spot Lens Units
E32-D32
Reflective Lens Units
Highspeed
mode
E32-T11L
E32-T81R-S
60
HighStandard
resolution
mode
mode
Superhighspeed
mode
---
Features
Model
number
4 dia.
(0.1 dia.)
Long-distance
sensing;
opening
angle: 5° to E39-F1
40° (heat
resistant
up to
200°C)
3 dia.
(0.1 dia.)
Side-view,
space-saving (heat
E39-F2
resistant
up to
200°C)
---
Long distance reflection
E39-F3
(heat resistant up to
200°C)
Spot diameter variable in the range 0.1 to 0.6 mm at distances in the range 6 to 15 mm
Small spot
E39-F3A
(variable)
Spot diameter variable in the range 0.5 to 1 mm at distances in the range 6 to 15 mm
E32-C41
0.1-dia. spot at a distance of 7 mm
E32-C31
0.5-dia. spot at a distance of 7 mm
E32-C41
Long distance,
0.5-dia. spot at a distance of 17 mm
small spot
Long-distance
Spot diameter of 4 mm max. at distances in the range 0 to
sensing,
20 mm
parallel
light
60
Small spot E39-F3A-5
60
E32-C31
60
Standard
object (min.
sensing
object) (mm)
*1
E32-C31
E32-C41
0.2-dia. spot at a distance of 17 mm
E39-F3B
E39-F3C
*1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set
to optimum values.
*2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
35
Accessories
Protective Spiral Tube
Appearance
Dimensions page
Application
61
Fiber protection
61
61
Applicable Fiber Units
Tube length Model number
M3-screw models
E32-D21/E32-D21R
E32-DC200E
E32-DC200F@
E32-C31
500 mm
E39-F32A5
1m
E39-F32A
M3-screw models
E32-T21@
(Except the E32-T21R.)
E32-TC200E
E32-TC200F@
500 mm
E39-F32B5
1m
E39-F32B
M4-screw models
E32-T11@ (except the E32-T11N Right-angle Model)
E32-TC200
E32-TC200B@
E32-T51
E32-D21L/E32-D21B
500 mm
E39-F32C5
1m
E39-F32C
M6-screw models
E32-D11@ (except the E32-D11N Right-angle Model)
E32-DC200
E32-DC200B
E32-CC200@
E32-D51
500 mm
E39-F32D5
1m
E39-F32D
Note: Before using a Protective Spiral Tube, remove the protective tube that protects the area between the head and the optical fiber provided with some models.
The Lens Unit and Spiral Tube cannot be used at the same time.
Other Accessories
Appearance
36
Dimensions
page
Application
Name
Remarks
Fiber Units that allow
free cutting
Provided with applicable Fiber
Units.
E39-F4
• 2 per set
• Provided with applicable Fiber Units.
E39-F9
62
Used to cut the fiber.
62
Attachments for in- Thin-fiber
serting thin fibers
Attachinto Amplifier Units ments
Fiber Units that allow
free cutting and have a
1.0-dia. sheath
62
Used to extend fibers.
Fiber Units that allow
free cutting and have a
2.2-dia. sheath
Cutter
Model
number
Applicable Fiber Units
Fiber Connectors
62
Easy-to-use, onetouch relay connectors
62
Used to bends in
sleeves.
Sleeve
Bender
E32-TC200B(4)
E32-TC200F(4)
E32-DC200F(4)
62
Used to secure the
3.5-dia. Fiber
Head
Mounting
Bracket
E32-T24S
E32-A03
Fiber Units that allow
free cutting
---
E39-F10
E39-F13: Used for Fiber Units
with a 2.2-dia. sheath.
E39-F14: Used for Fiber Units E39-F13
with a 1.0-dia. sheath.
E39-F14
E39-F15: Used to connect FiE39-F15
ber Units with different sheath
diameters, 1.0 mm and 2.2 mm.
---
E39-F11
Provided with applicable Fiber
Units.
E39-L83
Ratings/Characteristics
Standard models
Models
E32-D11
E32-D11N
E32-D11R
E32-D11U
E32-D12
E32-D12R
E32-D14L
E32-D14LR
E32-D15X
E32-D15XB
E32-D15XR
E32-D15Y
E32-D15YR
E32-D15Z
E32-D15ZR
E32-D21
E32-D211
E32-D211R
E32-D21B
E32-D21R
E32-D22
E32-D221B
E32-D22B
E32-D22R
E32-D24
E32-D24R
E32-D25X
E32-D25XB
E32-D25XR
E32-D25Y
E32-D25YR
E32-D25Z
E32-D25ZR
E32-DC200
E32-DC200B(B4)
E32-DC200BR(B4R)
E32-DC200E
E32-DC200F(F4)
E32-DC200FR(F4R)
E32-T11
E32-T11N
E32-T11R
E32-T11U
E32-T12
E32-T12B
E32-T12R
E32-T14L
E32-T14LR
E32-T15X
E32-T15XB
E32-T15XR
E32-T15Y
E32-T15YR
E32-T15Z
E32-T15ZR
E32-T21
E32-T21R
E32-T22
E32-T221B
E32-T222
E32-T222R
E32-T22B
E32-T22R
Ambient operating Ambient hutemperature range midity range
−40 to +70°C
Fiber core material
(sheath material)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (fluororesin coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
35% to 85% Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (fluororesin coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Permissible bending radius
R4
R1
R1
R4
R25
R1
R25
R1
R25
R4
R1
R25
R1
R25
R1
R4
R10
R1
R4
R1
R10
R4
R4
R1
R10
R1
R10
R4
R1
R10
R1
R10
R1
R25
R25
R1
R10
R10
R1
R4
R1
R1
R4
R25
R4
R1
R25
R1
R25
R4
R1
R25
R1
R25
R1
R4
R1
R10
R4
R10
R1
R4
R1
Tightening
force (N·m)
0.98
0.98
0.98
0.98
0.29
0.29
0.98
0.98
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.78
0.78
0.78
0.78
0.78
0.29
0.29
0.20
0.29
0.29
0.29
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.98
0.98
0.98
0.78
0.78
0.78
0.78
0.78
0.78
0.78
0.29
0.29
0.29
0.29
0.29
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.78
0.78
0.29
0.29
0.20
0.20
0.20
0.29
Pulling
force (N)
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
29.4
29.4
29.4
9.8
9.8
9.8
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
9.8
29.4
9.8
9.8
9.8
9.8
9.8
9.8
IEC standard degree of protection
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP40
IP40
IP40
IP40
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP40
IP40
IP40
IP40
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP40
IP40
IP40
IP40
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
37
Standard models (continued)
Models
E32-T24
E32-T24R
E32-T25X
E32-T25XB
E32-T25XR
E32-T25Y
E32-T25YR
E32-T25Z
E32-T25ZR
E32-TC200
E32-TC200A
E32-TC200B(B4)
E32-TC200BR(B4R)
E32-TC200E
E32-TC200F(F4)
E32-TC200FR(F4R)
Ambient operating Ambient hutemperature range midity range
−40 to +70°C
Fiber core material
(sheath material)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
35% to 85%
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (PVC coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Permissible bending radius
R10
R1
R10
R4
R1
R10
R1
R10
R1
R25
R25
R25
R1
R10
R10
R1
Tightening
force (N·m)
0.29
0.29
0.15
0.15
0.15
0.15
0.15
0.15
0.15
0.78
0.78
0.78
0.78
0.78
0.78
0.78
Pulling
force (N)
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
29.4
29.4
29.4
29.4
9.8
9.8
9.8
IEC standard degree of protection
IP67
IP67
IP67
IP67
IP67
IP40
IP40
IP40
IP40
IP67
IP67
IP67
IP67
IP67
IP67
IP67
Special-beam models
Ambient operating Ambient huFiber core material
Permissible bend- Tightening
Pulling
temperature range midity range
(sheath material)
ing radius
force (N·m) force (N)
E32-A10
−40 to +70°C
Plastic (polyethylene coating)
R25
0.53
29.4
E32-C11N
−40 to +70°C
Plastic (combination of PVC and polyethylene) R4
0.98
29.4
E32-C31
−40 to +70°C
Plastic (polyethylene coating)
R25
0.78
9.8
E32-C31N
−40 to +70°C
Plastic (combination of PVC and polyethylene) R4
0.29
9.8
E32-C41
−40 to +70°C
Plastic (polyethylene coating)
R25
0.78
9.8
E32-C42
−40 to +70°C
Plastic (polyethylene coating)
R25
0.29
9.8
E32-CC200
−40 to +70°C
Plastic (polyethylene coating)
R25
0.98
29.4
E32-CC200R
−40 to +70°C
Plastic (polyethylene coating)
R4
0.98
29.4
E32-D11L
−40 to +70°C
Plastic (polyethylene coating)
R25
0.98
29.4
E32-D16
−40 to +70°C
Plastic (PVC coating)
R4
0.53
29.4
E32-D21L
−40 to +70°C
Plastic (polyethylene coating)
R10
0.78
9.8
E32-D22L
−40 to +70°C
Plastic (polyethylene coating)
R10
0.29
9.8
E32-D32
−40 to +70°C
Plastic (polyethylene coating)
R25
0.29
9.8
E32-D32L
−40 to +70°C
Plastic (polyethylene coating)
R25
0.29
29.4
E32-D33
−40 to +70°C
Plastic (polyethylene coating)
R4
0.29
9.8
E32-D331
−40 to +70°C
Plastic (polyethylene coating)
R4
0.29
9.8
E32-D36P1
−40 to +70°C
Plastic (polyethylene coating)
R4
0.78
29.4
E32-L24L
−40 to +105°C
Plastic (polyethylene coating)
R10
0.29
9.8
E32-L24S
−40 to +70°C
Plastic (polyethylene coating)
R10
0.29
9.8
Plastic (polyethylene coating)
R25
0.29
19.6
E32-L25
−40 to +70°C
E32-L25A
−40 to +70°C
Plastic (polyethylene coating)
R25
0.29
19.6
E32-L25L
−40 to +105°C
Plastic (polyethylene coating)
R10
0.29
9.8
E32-L64
−40 to +300°C
Glass (SUS spiral coating)
R25
0.54
9.8
35% to 85%
E32-L86
−40 to +200°C
Glass (SUS spiral coating)
R25
0.54
9.8
E32-M21
−40 to +70°C
Plastic (PVC coating)
R25
0.49. 0.78*
9.8
E32-R16
−25 to +55°C
Plastic (polyethylene coating)
R25
0.54
29.4
E32-R21
−40 to +70°C
Plastic (polyethylene coating)
R10
0.39
9.8
E32-T11L
−40 to +70°C
Plastic (polyethylene coating)
R25
0.78
29.4
E32-T12L
−40 to +70°C
Plastic (polyethylene coating)
R25
0.29
29.4
E32-T14
−40 to +70°C
Plastic (polyethylene coating)
R25
0.49
29.4
E32-T16
−40 to +70°C
Plastic (polyethylene coating)
R25
0.49
29.4
E32-T16J
−40 to +70°C
Plastic (PVC coating)
R10
0.29
29.4
E32-T16JR
−40 to +70°C
Plastic (PVC coating)
R1
0.29
29.4
E32-T16P
−40 to +70°C
Plastic (PVC coating)
R10
0.29
29.4
E32-T16PR
−40 to +70°C
Plastic (PVC coating)
R1
0.29
29.4
E32-T16W
−25 to +55°C
Plastic (PVC coating)
R10
0.29
9.8
E32-T16WR
−25 to +55°C
Plastic (PVC coating)
R1
0.29
9.8
E32-T17L
−40 to +70°C
Plastic (polyethylene coating)
R25
0.78
29.4
E32-T21L
−40 to +70°C
Plastic (polyethylene coating)
R10
0.78
9.8
Plastic (polyethylene coating)
R1
0.20
9.8
E32-T223R
−40 to +70°C
E32-T22L
−40 to +70°C
Plastic (polyethylene coating)
R10
0.29
9.8
E32-T22S
−40 to +70°C
Plastic (PVC coating)
R10
0.29
29.4
E32-T24S
−40 to +70°C
Plastic (PVC coating)
R10
0.29
29.4
E32-T333-S5
−40 to +70°C
Plastic (polyethylene coating)
R10
0.29
9.8
E32-T334-S5
−40 to +70°C
Plastic (polyethylene coating)
R10
0.29
9.8
E32-T33-S5
−40 to +70°C
Plastic (PVC coating)
R10
0.29
9.8
*The strength depends on the section. Use 0.49 N•m max. to 5 mm from the tip and 0.78 N•m max. at a distance of more than 5 mm from the tip.
Models
38
IEC standard degree of protection
IP30
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP40
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP50
IP40
IP50
IP50
IP50
IP50
IP40
IP50
IP66
IP67
IP67
IP67
IP67
IP67
IP50
IP50
IP50
IP50
IP50
IP50
IP67
IP67
IP67
IP67
IP50
IP50
IP67
IP67
IP67
Environment-resistant models
Models
E32-D12F
E32-D14F
E32-D51
E32-D61
E32-D61-S
E32-D73
E32-D73-S
E32-D81R
E32-D81R-S
E32-T11F
E32-T12F
E32-T14F
E32-T51
E32-T51F
E32-T51V
E32-T54
E32-T54V
E32-T61-S
E32-T81F-S
E32-T81R-S
E32-T84S-S
E32-T84SV
Ambient operating Ambient hutemperature range midity range
−40 to +70°C
−40 to +70°C
−40 to +150°C
−60 to +350°C
−60 to +350°C
−40 to +400°C
−40 to +400°C
−40 to +200°C
−40 to +200°C
−40 to +70°C
−40 to +70°C
35% to 85%
−40 to +70°C
−40 to +150°C
−40 to +150°C
−25 to +120°C
−40 to +150°C
−25 to +120°C
−60 to +350°C
−40 to +200°C
−40 to +200°C
−40 to +200°C
−25 to +200°C
Fiber core material
(sheath material)
Plastic (fluororesin coating)
Plastic (fluororesin coating)
Plastic (fluororesin coating)
Glass (SUS spiral coating)
Glass (SUS spiral coating)
Glass (SUS spiral coating)
Glass (SUS spiral coating)
Glass (fluororesin coating)
Glass (fluororesin coating)
Plastic (fluororesin coating)
Plastic (fluororesin coating)
Plastic (fluororesin coating)
Plastic (fluororesin coating)
Plastic (fluororesin coating)
Glass (fluororesin coating)
Plastic (fluororesin coating)
Glass (fluororesin coating)
Glass (SUS spiral coating)
Glass (fluororesin coating)
Glass (fluororesin coating)
Glass (fluororesin coating)
Glass (SUS spiral coating)
Permissible bending radius
R40
R40
R35
R25
R25
R25
R25
R10
R10
R4
R40
R40
R35
R40
R30
R35
R30
R25
R10
R10
R25
R25
Tightening
force (N·m)
0.78
0.78
0.98
0.98
0.98
0.78
0.78
0.78
0.78
0.29
0.78
0.78
0.78
0.78
0.29
0.29
0.29
0.78
0.78
0.78
0.29
0.29
Pulling
force (N)
29.4
29.4
29.4
29.4
29.4
29.4
29.4
9.8
9.8
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
9.8
9.8
9.8
29.4
IEC standard degree of protection
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
IP67
--IP67
--IP67
IP67
IP67
IP67
---
Fiber core material
(sheath material)
Plastic (fluororesin coating)
Plastic (fluororesin coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Glass (SUS spiral coating)
Plastic (polyethylene coating)
Plastic (fluororesin coating)
Glass (SUS spiral coating)
Plastic (polyethylene coating)
Tip: Glass and fluororesin coating
Amplifier insert: Plastic (fluororesin coating)
(Fluororesin coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Plastic (polyethylene coating)
Glass (SUS spiral coating)
Plastic (polyethylene coating)
Permissible bending radius
R4
R4
R1
R10
R10
R10
R25
R25
R25
R25
R35
R25
R4
Tightening
force (N·m)
----0.29
0.29
0.29
0.29
0.53
0.53
0.53
0.53
0.53
0.53
---
Pulling
force (N)
9.8
9.8
9.8
9.8
9.8
9.8
9.8
9.8
29.4
9.8
9.8
9.8
29.4
IEC standard degree of protection
IP50
IP50
IP50
IP50
IP50
IP50
IP40
IP40
IP30
IP40
IP40
IP40
IP67
Application-corresponding models
E32-A01
E32-A02
E32-A03
E32-A03-1
E32-A04
E32-A04-1
E32-A07E1(E2)
E32-A08
E32-A08H2
E32-A09
E32-A09H
E32-A09H2
E32-D36T
Ambient operating Ambient hutemperature range midity range
−40 to +70°C
−40 to +70°C
−40 to +70°C
−40 to +70°C
−40 to +70°C
−40 to +70°C
−40 to +70°C
−40 to +70°C
−40 to +300°C
−40 to +70°C
−40 to +150°C
35% to 85%
−40 to +300°C
−40 to +70°C
E32-D82F1
−40 to +200°C
E32-D82F2
E32-G14
E32-L16-N
E32-L25T
E32-L66
E32-T14
−40 to +200°C
−40 to +70°C
−40 to +70°C
−40 to +70°C
−40 to +300°C
−40 to +70°C
Models
R40
0.29
29.4 IP68
R40
R25
R25
R10
R25
R25
0.29
0.49
0.29
--0.53
0.49
29.4
29.4
29.4
9.8
9.8
29.4
IP68
IP67
IP40
IP50
IP40
IP67
39
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver.
Flexible
Standard Standard/Flexible Models
E32-T11N
8.4 dia.
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Model display tube
2.2 dia.
7
E32-TC200
E32-T11R
R25
Sensing surface:
1 dia.
7
5.5
2,000
M4×0.7 (brass/nickel plating)
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
M2.6×0.45
2.2 dia.
4.7
14.7
(45)
10
3
M4×0.7 (brass/nickel plating)
M2.6×0.45
M4 nuts (brass/nickel plating)
Washer (nickel-plated iron)
included (4 of each)
3
3.2
14
Sensing surface:
1 dia.
E32-TC200E
E32-TC200A
E32-T21R
R10
Sensing surface:
0.5 dia.
M3×0.5 (brass/nickel plating)
R25
M3×0.5 (brass/nickel plating)
Sensing surface:
1 dia. *
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
2,000
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
2.2 dia.
1 dia.
3 dia.
E39-F9: Included
2.5
11
2,000
9.5
13.5
2,000
E32-T22 R10
E32-T22R
*E32-T21R: 0.5 dia.
E32-T12 R25
E32-T12R
2 dia. (SUS303)
Sensing surface:
0.5 dia.
Heat-shrinkable tube
1.4 dia.
E39-F9: Included
12
17
22
2.2 dia.
3 dia. (brass/nickel plating)
11
3
2,000
E32-T222 R10
E32-T222R
2.4 dia.
Sensing surface:
1 dia.
1 dia.
14
2,000
E32-T15X R25
E32-T15XR
Sensing surface:
0.5 dia.
1.5 dia.
(brass/nickel plating)
E39-F9: Included
10
Two, 2.2 dia. mounting holes with
two, 4.4 dia. countersinks on both sides
(aluminum)
Sensing surface:
1 dia.
1 dia.
8
2.2 dia.
5.5
1.5
2,000
3
2.5
7.5
2,000
15
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk screw M2 × 8 4 pcs)
included
E32-T25X R10
E32-T25XR
Sensing surface:
0.5 dia.
E32-TC200B R25
E32-TC200B4 R25
E32-TC200BR
E32-TC200B4R
Mounting holes Two 2.2 dia.
Two, 4.4 dia. countersinks on one side
(aluminum)
1 dia.
4.5
7 1
2
5
12
E32-TC200F R10
E32-TC200F4 R10
E32-TC200FR
E32-TC200F4R
90
(40)*
3.2
11
Heat-shrinkable tube
3 dia. (SUS303)
M3×0.5 (brass/nickel plating)
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
1 dia.
Sensing surface:
0.5 dia.
2.8
3 dia.
2
30
35
E39-F9: Included
40
2,000
* ( ): E32-TC200B4/E32TC200B4R
E32-T14L R25
E32-T14LR
Stainless-steel tube
0.9 dia. max. (SUS304)
90
(40)*
2.2 dia.
2,000
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk
screw M2 × 8 4 pcs) included
2.5
Width 7,
thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Stainless-steel tube
1.2 dia. max.
(SUS304)
E39-F9: Included
2.5
M4×0.7 (coarse thread)
(brass/nickel plating)
Sensing surface: 1 dia.
11
2,000
* ( ):E32-TC200F4/E32TC200F4R
Sensing surface
12
2,000
2.2 dia.
Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver.
Flexible
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Standard Standard/Flexible Models
E32-T24 R10
E32-T24R
E32-T15Y R25
E32-T15YR
2 dia. (SUS304)
Stainless-steel tube
1 dia. max.
4
Heat-shrinkable tube
1.4 dia.
1 dia.
(aluminum)
3
Two, 2.2 dia. mounting holes
with two, 4.4 dia. countersinks on both sides
Sensing
surface
Sensing
surface
1.25
2.2 dia.
E39-F9: Included
15
15
8 5.5
12
35
2,000
7.5
2.5
15
2,000
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk screw M2 × 8 4 pcs) included
E32-T25Y R10
E32-T25YR
E32-T15Z R25
E32-T15ZR
(aluminum)
3
Sensing surface
2
Two, 2.2 dia. mounting holes with
two, 4.4 dia. countersinks on one side
Sensing
surface
3
1 dia.
8
7 4.5
E32-T25Z R10
E32-T25ZR
7
2,000
15
2,000
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk screw M2 × 8 4 pcs) included
2.2 dia.
7.5
2.5
5
12
2
1.5 4
5.5
E39-F9: Included
2.5
Two, 2.2 dia. mounting holes
with two, 4.4 dia. countersinks on both sides
(aluminum)
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk screw M2 × 8 4 pcs) included
Sensing surface
Two, 2.2 dia. mounting holes with
two, 4.4 dia. countersinks on one side
3
1 dia.
(aluminum)
4.5 1
E39-F9: Included
2.5
5
12
2,000
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk screw M2 × 8 4 pcs) included
Mounting hole dimensions (recommended)
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R@ Standard
(Unit:mm)
A
Minimum bending
radius
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Fluororesin coating
R25
R30
R35
R40
41
Flexible
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Standard Models Break-resistant/Coated Models
E32-T11
E32-T11U
Break-resistant
E32-T21
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
M4×0.7
(brass/nickel plating)
Protective tube
M2.6×0.45
3.2
Protective tube
2.2 dia.
1 dia.
E39-F9: Included
15
15
3.3
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
M3×0.5
(brass/nickel plating)
14
Sensing surface: 1 dia.
2.5
2,000
11
Sensing surface: 0.5 dia.
2,000
E32-T221B
E32-T12B
Sensing surface: 0.5 dia.
Sensing surface: 1 dia.
2.4 dia. 3 dia. (brass/nickel plating)
3
17
11
14
E32-T15XB
1.5 dia. (brass/nickel plating)
12
1 dia.
E39-F9: Included
2,000
(aluminum)
2.2 dia.
5.5
8 1.5
2.5
3
2,000
1 dia.
Two, 2.2 dia. mounting holes
with two, 4.4 dia. countersinks on both sides
Sensing surface:
1 dia.
E39-F9: Included
10
Heat-shrinkable tube
22
2,000
E32-T22B
Sensing surface:
0.5 dia.
1.4 dia.
2 dia. (SUS303)
2.2 dia.
7.5
15
2,000
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk screw M2 × 8 4 pcs) included
E32-T25XB
Sensing surface:
0.5 dia.
Two, 2.2 dia. mounting holes with
two, 4.4 dia. countersinks on one side
(aluminum)
1 dia.
4.5
7 1
E39-F9: Included
5
2
2.5
12
2,000
Note: 1. Set of two symmetrical parts.
2. Mounting screws (countersunk screw M2 × 8 4 pcs) included
42
Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver.
Flexible
Special-beam Models Long-distance/High-power Models
E32-T17L
E32-T14
R25
Break-resistant
R25
Sensing surface
Lens (PMMA)
4.4 dia.
M14×1 (ABS)
Sensing surface
lens diameter:
10 dia. (PMMA)
Fluororesin coating
Heat-resistant ABS
8.2
8
R3.5
Two, 3.2 dia. mounting holes
2.2 dia.
8
10.5
7
10±0.2
2.5
23
9.2
42
E32-T12L
R25
Sensing surface:
1.4 dia.
M4×0.7 (brass/nickel plating)
2.4 dia. 3 dia. (brass/nickel plating)
2.2 dia.
11
14
2.2 dia.
11
2,000
14
2,000
E32-T22L
R10
Sensing surface M3×0.5 (brass/nickel plating)
0.9 dia.
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
1 dia.
11
R10
2 dia. (SUS304)
Sensing surface
0.9 dia.
Heat-shrinkable tube
1.8 dia.
(2)
E39-F9: Included
(1.7)
2.5
R25
3
3
3.2
2,000
Sensing surface: 1.4 dia.
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
M2.6×0.45
11.2
16
25.2
10,000
E32-T21L
Nitrile rubber
Width 19, thickness 5 (aluminum)
2.2 dia.
E32-T11L
R@ Standard
Cutting free (Cutter provided)
E39-F9: Included
17
22
2,000
Mounting hole dimensions (recommended)
1 dia.
12
2,000
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R@ Standard
(Unit:mm)
A
Minimum bending
radius
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Fluororesin coating
R25
R30
R35
R40
43
Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver.
Flexible
Special-beam Models Ultracompact/Thin-sleeve Models
E32-T33-S5
E32-T223R
Sensing surface
0.5 dia.
1 dia.
5
E32-T334-S5
5
10
12
3 dia. (SUS303)
Heat-shrinkable tube
1 dia.
1 dia.
0.22 dia.
Fiber Attachment*
20
E39-F9: Included
1,000
R10
Sensing surface
0.1 dia.
Heat-shrinkable tube
0.25 dia.
12
20
3 dia. (SUS303)
Fiber Attachment*
12
10
5
1 dia.
Heat-shrinkable tube
10
2,000
R10
R@ Standard
3 dia. (SUS303)
0.5 dia.
E39-F9: Included
Sensing surface
0.125 dia.
Fluororesin coating
R10
Sensing surface
0.25 dia.
1 dia. (stainless steel)
10
E32-T333-S5
Break-resistant
Cutting free (Cutter provided)
20
1,000
1,000
*The Fiber Attachment is attached with adhesive and cannot be removed.
*The Fiber Attachment is attached with adhesive and cannot be removed.
Special-beam Models Fine-beam (narrow vision field) Models
E32-T22S
E32-T24S
R10
R10
1.8
0.4
Sensing surface
1.7 dia.
3 dia. (brass/nickel plating)
2.2 dia.
(brass/nickel plating)
11
17.6 3.5 dia.
2.2 dia.
3.2
2,000
15
E39-L83 Mounting Bracket
(SUS) (provided)
3.2
3
10
20.5
2,000
2 dia.
2
Sensing surface
Special-beam Models Area-sensing Models
E32-T16W R10
E32-T16WR
5
E32-M21
M3×0.35
(SUS303)
23
18
Sensing surface
(3×30)(PMMA)
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
12
18.5
R25
Silicon tube *
Four, 1 dia.
*One set of silicon tubes is black
and the other set is gray.
Usethis difference to distinguish
between the emission and
reception sides.
69
65
45
28
11
(ABS)
Two, 3.2 dia. mounting holes
with two, 6 dia. countersinks
2.2 dia.
44
2,000
2,000
23
Flexible
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Special-beam Models Area-sensing Models
E32-T16P R10
E32-T16PR
E32-T16
R25
Mounting bracket (Zinc-plated iron) provided
Two, 3.2 dia. mounting holes
with two, 6 dia. countersinks
on both sides
14.5
10.7
4
4
7
Sensing surface
(2×11)
(PMMA)
19
27
Break-resistant
20
(Heat-resistant ABS)
20
15.5
8.4
3
2,000
(Heat-resistant ABS)
2.2 dia.
25
*Provided with stickers with
slits of width 0.5 and 1 mm (2 of each).
E32-T16J R10
E32-T16JR
2-M3
20
58
2
Receiver
Sensing surface
(2×11)
(PMMA)
43.2
8.85
Emitter
32.5
2,000
17.8
14.5
10.7
2.2 dia.
3.3
2
4
33
4
27
Sensing surface
(2×10)
(PMMA)
6 dia.
7
*Provided with stickers with
slits of width 0.5 and 1 mm (2 of each).
19
(ABS)
Two, 3.2 dia. mounting holes
with two, 6 dia. countersinks
on both sides
2.2 dia.
2,000
Mounting hole dimensions (recommended)
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R@ Standard
(Unit:mm)
A
Minimum bending
radius
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Fluororesin coating
R25
R30
R35
R40
45
Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver.
Flexible
Environment-resistant Models Heat-resistant Models
E32-T51
R35
E32-T54
M4×0.7 (brass/nickel plating)
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Sensing surface
1.5 dia.
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
2.2 dia.
R35
Sensing surface
2.45
3 dia. (SUS303)
2.2 dia.
2 dia.
2.85 dia.
1
25
15
17
Note: The maximum allowable temperature is 150°C. The maximum allowable temperature for continuous operation is 130°C.
E32-T81R-S
R10
Width 7,
thickness 2.4 (SUS304)
Washer (SUS)
Note: The maximum allowable temperature is 150°C. The maximum
allowable temperature for continuous operation is 130°C.
Protective tube
Fluororesin tube 2 dia.
M2.6×0.45
4 dia.
4 dia.
2.2 dia.
Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit
(indicated by *), however, must stay within the
Amplifier Unit's operating temperature range.
*
(75)
20
10
2,000
30(B)
A
E32-T84S-S
E32-T61-S
R25
30
2,000
*
3 dia.
4 dia.
*2
3
20
Note: The maximum allowable temperatures
for sections A and B are 200°C and
110°C, respectively. The section inserted into the Amplifier Unit (indicated
by *), however, must stay within the
Amplifier Unit's operating temperature
range.
3 dia. (SUS303)
Sensing surface
Lens (2 dia.)
10
2.2 dia.
*1
30
2,000
25(B)
A
3.5 dia.
12
2.8 dia. flexible tubes
(SUS304)
4 dia.
M2.6×0.45
Flexible tube:
2.9 dia.
(stainless steel)
90°
30 max. 6
M4×0.7 (SUS303)
Width 7, thickness 2.4 (SUS304)
Washer (SUS)
2.2 dia.
4 dia.
4 dia.
R25
Sensing surface
1 dia.
25(B)
A
12
14.2
R5
2,000
M4×0.7 (SUS303)
Sensing surface
0.7 dia.
3
20
45
2,000
*2 The diameter is 6 mm if the fiberlength exceeds 10 m.
Note: The maximum allowable temperatures for sections A and B are 200°C
and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *1), however, must stay within the Amplifier Unit's operating
temperature range.
Environment-resistant Models Chemical-resistant Models
E32-T11F
E32-T12F
R4
lens diameter: 3.7 mm
7.2 dia. (PFA)
R40
nut (PFA)
2.2 dia. (Fluororesin)
Sensing surface
Lens 4 dia.
10
5 dia. (Fluororesin)
4 dia.
2.2 dia.
R3.6
(10
19.8
.7)
35
3
10
2,000
20
2,000
E32-T14F
E32-T51F
R40
5 dia. (Fluororesin)
4 dia.
2.2 dia.
R40
Sensing surface
lens diameter:
3.7 dia.
4.5
5 dia. (Fluororesin)
2.2 dia.
20
2,000
21
2,000
E32-T81F-S
100
100
R10
6 dia.
Sensing surface:
3.7 dia
PFA cover
(R6)
Protective tube
2 dia. (PFA tube)
4 dia.
(70)
(0.8)
2.2 dia.
*
2,000
30
A
46
100
30(B)
Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit
(indicated by *), however, must stay within the
Amplifier Unit's operating temperature range.
Flexible
Environment-resistant Models Vacuum-resistant Models
E32-T51V
E32-T54V
R30
Break-resistant
Fluororesin coating
R30
8
4
Width 8 (SUS304)
Washer (SUS304)
M4×0.7
(Aluminum)
M2.6×0.45
4 dia.
4 dia.
3 dia.
2.2 dia.
Sensing surface: 1.15 dia.
M2.6×0.45
3
12
1,000
15
Connected to flange
(vacuum side)
4 dia. 2.2 dia.
3 dia.
3 dia. (SUS304)
Sensing surface
1.15 dia.
R@ Standard
Cutting free (Cutter provided)
4.5
Connected to flange
(vacuum side)
3
20
5 dia.
4 dia.
R9
18
4
26
1,000
(30)
26
(3)
E32-T84SV
3 dia.
(SUS304)
E39-F1V
Sensing surface: 2 dia.
R25
12
14.2
0.5 dia.
hole
1,000
8.9
M2.6×0.45
Effective depth: 3.8
Spot-facing depth: 0.9
4 dia.
12
Connected to flange
(vacuum side)
3.5 dia.
30 max. 6
3 dia. 90°
Flexible tube:
(stainless steel) 2.9 dia.
4 dia.
6
2.2 dia.
4 dia.
Material:
Aluminum for body and optical glass for the lens itself.
R5
26
E32-VF4
24
36 dia.
Four,
10 dia.
49
8
E32-VF1
80
70 dia.
44 dia.
(96)
(63)
10
5
22
30
(23)
22
20 dia.
19
M14×2
45°
6 (33.53)
80
Flange
Flange
V40 O-ring
90 dia.
One nut
One spring washer
Two, connectors
V15 O-ring
Note 1. Perform mounting so that the V15 O-ring is on the atmospheric-pressure side of the vacuum chamber wall.
2. Mounting-hole cutout dimensions: 14.5 dia. ±0.2 mm
Note 1. Perform mounting so that the V40 O-ring is on the atmospheric-pressure side of the vacuum chamber wall.
2. Mounting-hole cutout dimensions: 38 dia. ±0.5 mm
E32-T10V-2M
E39-L54V
R25
4.5
8
4.1
2.2 dia.
4
23
15
2,000
Material: Stainless steel (SUS304)
Mounting hole dimensions (recommended)
0.5
4.1
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
0
14 dia.
Fluororesin coating
R@ Standard
(Unit:mm)
A
Minimum bending
radius
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R25
R30
R35
R40
47
Fiber Units with Reflective Sensors
Flexible
E32-D11N
Model display tube
E32-DC200
E32-D11R
R@ Standard
Two, 2.2 dia.
R25
M6×0.75 (ADC)
Sensing surface:
Two, 1 dia.
(45)
Fluororesin coating
Cutting free (Cutter provided)
Standard Models Standard/Flexible Models
Sensing surface:
Two, 1 dia.
Break-resistant
Width 10, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
4 dia.
2,000
Two, 2.2 dia.
M6×0.75 (brass/nickel plating)
11
15.7
4.7
10
3
4.8
17
2,000
8
M6 nuts (brass/nickel plating)
Washer (nickel -plated iron) included (2 of each)
10
12 dia.
E32-D211 R10
E32-D211R
E32-DC200E
E32-D21R
M4×0.7 (SUS303)
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
Two, 1 dia.
Two, 1 dia.
15
E39-F9: Included
2,000
2.5
E39-F9: Included
3
3.2
M3×0.5 (SUS304)
Sensing surface
Two, 0.5 dia.
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Sensing surface
Two, 0.5 dia.
R10
11
2,000
E32-D12 R25
E32-D12R
E32-D22 R10
E32-D22R
Sensing surface
Two, 1 dia.
3 dia. (SUS304)
15
Heat-shrinkable tube
Two, 2.2 dia.
Sensing surface
Two, 0.5 dia.
2.7 dia.
3 dia. (brass/nickel plating) Two, 1 dia.
3
135
2,000
E32-D15X R25
E32-D15XR
E32-D25X R10
E32-D25XR
Two, 2.2 dia. mounting holes
with two, 4.4 dia. countersinks
on both sides
Sensing surface: (aluminum)
Two, 1 dia.
Two, 2.2 dia.
7.5
10 2.5
3
Sensing surface
2-0.5 dia.
5
2.5
2,000
12
2,000
15
Note: Mounting screws (countersunk
screw M2 × 8 2 pcs) included
Note: Mounting screws (countersunk
screw M2 × 8 2 pcs) included
E32-DC200B R25
E32-DC200B4 R25
E32-DC200BR
E32-DC200B4B
Sensing surface:
Two, 1 dia.
M6×0.75 (brass/nickel plating)
(fine thread)
Stainless-steel tube
2.5 dia. max.
(SUS304)
Width 10,
thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
E32-DC200F R10
E32-DC200F4 R10
E32-DC200FR
E32-DC200F4R
48
90
(40
40)*
17
2,000
* ( ):E32-DC200B4/E32-DC200B4R
M3×0.5 (SUS304)
Stainless-steel tube
1.2 dia. max. (SUS304)
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
Sensing surface
Two, 0.5 dia.
Two, 2.2 dia.
5.2
Two, 1 dia.
E39-F9: Included
5.5
2
7.5
Two, 2.2 dia. mounting holes with
two, 4.4 dia. countersinks
on one side
(aluminum)
8 1.5
2.5
E39-F9: Included
2,000
15
2.5
Two, 1 dia.
E39-F9: Included
90
(40
40)*
11
2,000
* ( ):E32-DC200F4/E32-DC200F4R
Flexible
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
E32-D14L R25
E32-D14LR
(SUS304)
Heat-shrinkable tube
Two, 2.2 dia.
E32-D24 R10
E32-D24R
Stainless-steel tube
2 dia. max.
3 dia. (SUS304)
Heat-shrinkable tube
Two, 1 dia.
5.7
1.25
2
6 dia.
15
12
30
35
Light baffle
E39-F9: Included
15
12
35
2,000
2,000
Sensing surface
Light baffle
Sensing surface
E32-D15Y R25
E32-D15YR
2.8
E32-D25Y R10
E32-D25YR
2.4
(aluminum)
Sensing surface
2
Mounting holes Two, 2.2 dia.
Two, 4.4 dia. countersinks on both sides
Two, 2.2 dia.
Two, 2.2 dia. mounting holes with
two, 4.4 dia. countersinks on one side
Sensing surface
7.5
10
7.5
2.5
E32-D15Z R25
E32-D15ZR
Two, 2.2 dia. mounting holes
with two, 4.4 dia. countersinks
on both sides
(aluminum)
Sensing surface
Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included
E32-D25Z R10
E32-D25ZR
Sensing surface
2
10
8
1.2 0.9
E39-F9: Included
5.5
5
2.5
2,000
2,000
12
Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included
Mounting hole dimensions (recommended)
Two, 1 dia.
3
7.5
15
Two, 2.2 dia. mounting holes
with two, 4.4 dia. countersinks
on one side
(aluminum)
Two, 2.2 dia.
4
2.5
2,000
12
2,000
Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included
2.2
1.4
7.5
5
2.5
15
Two, 1 dia.
E39-F9: Included
5.5
8
3
(aluminum)
1.4
2.3
3
Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R@ Standard
(Unit:mm)
A
Minimum bending
radius
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Fluororesin coating
R25
R30
R35
R40
49
Fiber Units with Reflective Sensors
Flexible
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Standard Models Break-resistant/Coated Models
E32-D11
E32-D11U
Break-resistant
M6×0.75
(brass/nickel plating)
Sensing surface
Two, 1 dia.
Width 10, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
15
5.2
Two, 2.2 dia.
Protective tube
17
7
2,000
E32-D21B
E32-D21
M4×0.7 (SUS303)
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Sensing surface
Two, 0.5 dia.
Sensing surface
Four, 0.25 dia.
M3×0.5 (brass/nickel plating)
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
Two, 1 dia.
Two, 1 dia.
Protective tube
E39-F9: Included
3
3.2
15
15
2.5
E39-F9: Included
11
2,000
2,000
Enlarged illustration of sensing surface
Two 0.25 dia.
emission fibers
Two, 0.25 dia.
reception fibers
E32-D221B
E32-D22B
Sensing surface
Two, 0.5 dia.
3 dia. (brass/nickel plating)
1.5 dia. (SUS304)
Sensing surface
Four, 0.25 dia.
Two, 1 dia.
1 dia.
E39-F9: Included
15
Brancher (ABS): 3.5 dia.
Fiber Attachment*
15
2,000
15
2,000
100
*The Attachment is attached with adhesive and cannot be removed.
Enlarged illustration of sensing surface
Two 0.25 dia.
emission fibers
Two, 0.25 dia.
reception fibers
E32-D15XB
Sensing surface:
Two, 1 dia.
E32-D25XB
Two, 2.2 dia. mounting holes
with two, 4.4 dia. countersinks
on both sides
(aluminum)
3
7.5
15
E39-F9: Included
5
2
2,000
Note: Mounting screws (countersunk
screw M2 × 8 2 pcs) included
50
Two, 1 dia.
5.5
8 1.5
2.5
Two, 2.2 dia. mounting holes with
two, 4.4 dia. countersinks on one side
(aluminum)
7.5
10 2.5
Sensing surface:
Two, 1 dia.
Two, 2.2 dia.
2.5
12
2,000
Note: Mounting screws (countersunk
screw M2 × 8 2 pcs) included
Flexible
E32-D11L
Sensing surface
Lens Two,
5.8 dia lenses
9
R@ Standard
R25
M6×0.75 (brass/nickel plating)
Two, 3.2 dia. mounting holes
Two, 6 dia. countersinks on both sides
(aluminum)
Fluororesin coating
Cutting free (Cutter provided)
Special-beam Models Long-distance/High-power Models
E32-D16
Break-resistant
Sensing surface
Two, 1.4 dia.
Width 10, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Two, 2.2 dia.
4 dia.
8.5
Two, 2.2 dia.
17.5
3
5.2
22
E32-D21L
R10
2,000
E32-D22L
M4×0.7 (brass/nickel plating)
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Sensing surface
Two, 0.9 dia.
R10
Sensing surface
2.7 dia.
Two, 0.9 dia.
Two, 1 dia.
15
3 dia. (brass/nickel plating)
2,000
15
2,000
Two, 1 dia.
E39-F9: Included
3
E39-F9: Included
3
3.2
2,000
20
6.5
11
Special-beam Models Ultracompact/Thin-sleeve Models
E32-D33
E32-D331
R4
Stainless-steel tube
0.8 dia. max.
3 dia. (SUS303)
Sensing surface
Two, 0.25 dia.
15
Heat-shrinkable tube
Stainless-steel tube
0.5 dia. max.
Sensing surface
Two, 0.125 dia.
Two, 1 dia.
12
15
R4
2 dia. (SUS303)
Irraxtube: 1.2 dia.
Brancher: 3.5 dia.
E39-F9: Included
15
15
2,000
35
2,000
15
100
Fiber Attachment*
*The Attachment is attached with adhesive and cannot be removed.
Mounting hole dimensions (recommended)
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R@ Standard
(Unit:mm)
A
Minimum bending
radius
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Fluororesin coating
R25
R30
R35
R40
51
Fiber Units with Reflective Sensors
Flexible
Break-resistant
Fluororesin coating
Cutting free (Cutter provided)
Special-beam Models Coaxial/Small-spot Models
E32-C11N
E32-C31N
1 dia. emission fibers
0.5 dia. emission fibers
Two, 2.2 dia.
Model display tube
Sixteen, 0.265 dia.
reception fibers
Model display tube Two, 1 dia.
Four, 0.25 dia.
reception fibers
(45)
(45)
2,000
3
2,000
M6×0.75 (brass/nickel plating)
20.5
13.5
7
6
10
6.5 dia.
5.5
M6 nuts (brass/nickel plating)
Washer (nickel-plated iron)
included (2 of each)
5
10
8
12 dia.
Note: The Emitter fiber is shown with a white line.
M3 nuts (brass/nickel plating)
Washer (brass/nickel plating) included (2 of each)
E32-CC200 R25
E32-CC200R
E32-D32L
R25
M6×0.75 (brass/nickel plating)
1 dia.
emission fibers
Brancher (heat-resistant,
ABS, black): 6 dia.
Width 10, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Two, 2.2 dia.
2.5 dia.
15
23
Sixteen, 0.25 dia. reception fibers
R25
0.5 dia.
emission fibers
Two, 1 dia.
2 dia. (SUS303)
20
12
E39-F9: Included
25
R25
2,000
M3×0.5 (SUS303)
Brancher (ABS resin):3.5 dia.
Width 5.5,
thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
0.175 dia.
emission fibers
White markings:Emission side
(heat-shrinkable tube)
Two, 1.2 dia.
2
Two, 1 dia.
12
E39-F9: Included
22
2,000
Four, 0.25 dia.
reception fibers
2.5
Note: There is a white line on the cable fiber that is inserted in the emitter-side port.
Heat-shrinkable tube
3 dia.
15
Four, 0.25 dia.
reception fibers
1,570
15
2,000
R25
Width 5.5, thickness 1.8 (nickel-plated brass)
Washer (nickel-plated brass)
Heat-shrinkable tube
400
Note: There is a yellow dotted line on the fiber that is inserted in the emitter-side
port.
E32-D32
M3×0.5 (SUS303)
0.5 dia.
emission fibers
Two, 2.2 dia.
Sixteen, 0.265 dia.
reception fibers
2,000
Note: There is a white line on the fiber that is inserted in the emitter-side port.
E32-C41
3 dia. (SUS304)
1 dia. emission fibers
3
5.2
E39-F9: Included
M3×0.5 (brass/nickel plating)
18
24
E32-C31
R@ Standard
Note: There is a white line on the cable fiber that is inserted in the emitter-side
port.
E32-C42
R25
2 dia. (SUS303)
Brancher
3 dia.
(ABS resin):
Irraxtube: 2.6 dia. 3.5 dia.
0.175 dia.
emission fibers
White markings:
Emission side
(heat-shrinkable tube)
Two, 1.2 dia.
Irraxtube: 2.6 dia.
Six, 0.175 dia.
reception fibers
Six, 0.175 dia.
reception fibers
15
17
(100)
Fiber Attachment*
22
1,000
* The Fiber Attachment is attached with
adhesive and cannot be removed.
52
15
15
22
(100)
2
Fiber Attachment*
1,000
* The Fiber Attachment is attached with
adhesive and cannot be removed.
Flexible
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Special-beam Models Area-sensing Models
E32-D36P1
25
2,000
5
10
Two, 2.2 dia.
15
2.5
Two, 3.2 dia. mounting holes
………
2
Sensing surface: 32 × 0.265 dia.
(emission and reception fibers
in alternating arrangement)
10.85
5
(brass/nickel plating)
Special-beam Models Retroreflective Fiber Units
E32-R21 R10
(An E39-R3 Reflector is provided as an accessory.)
E32-R16 R25
(An E39-R1 Reflector is provided as an accessory.)
27
15
Width 10, thickness 3 (polyacetal)
Washer (NBR)
M6×0.75
(ABS)
Sensing surface
Lends
(PMMA)
7
Silicon tube
13
Two, 1 dia.
5 dia.
2.2
2.8
11
10
7.2
E39-F9: Included
14
Sensing surface
Lends (PMMA)
(6)
16
(ABS)
2,000
17.8
27.8
21.5
15.2
8
Two, 2.2 dia.
Standard length: 2 m
17
21
22.5
Two, M3 set screws (provided)
Mounting bracket E39-L4
(Zinc-plated iron) provided
Mounting hole dimensions (recommended)
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R@ Standard
(Unit:mm)
A
Minimum bending
radius
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Fluororesin coating
R25
R30
R35
R40
53
Fiber Units with Reflective Sensors
Flexible
E32-L16-N
R10
R@ Standard
Two, 3.2 dia.mounting holes with
two, 6 dia. Countersinks
Two, 2.2 dia.
(ABS)
3.5
5.5
11
R25
Sensing surface
Two, 3.2 dia. mounting holes
with two, 6 dia. Countersinks
on one side
Fluororesin coating
Cutting free (Cutter provided)
Special-beam Models Convergent-reflective Models
E32-L24S
Break-resistant
14 10.6
Two, 1 dia.
Model display tube
0.95
Sensing surface
3.5
2
2.7
7
14
(45)
7
6.8
2,000
2,000
20.5
E39-F9: Included
3.8
2.5
(PVC)
E32-L24L
E32-L25L
R10
Sensing distance
R10
Sensing surface Two, 3.2 dia.
Sensing surface
4
Sensing distance
1.5
3.6
3.3
18
Side-view prism (PC)
4
Two, 3.2 dia. mounting holes
with two, 6 dia. countersinks
on both sides
4
6
20
18
6
E39-F9: Included
E39-F9: Included
16
Two, 1 dia.
6.5
Two, 1 dia.
6.5
(Polycarbonate)
(Polycarbonate)
2,000
E32-L25
Two, 3.2 dia. mounting holes
with two, 6 dia. countersinks
on both sides
E32-L25A
R25
20
10
Sensing
surface
5
20
R25
20
10
Sensing distance
5
6.5
6.5
2,000
Sensing
surface
Sensing distance
6.5
Two, 2.2 dia.
20
6.5
(Heat-resistant ABS)
2,000
(Heat-resistant ABS)
Two, 3.2 dia. mounting holes with
two, 6 dia. countersinks on one side
Two, 3.2 dia. mounting holes with
two, 6 dia. countersinks on one side
2,000
Two, 2.2 dia.
Note: There is a white line on the fiber that is inserted in the emitter-side
port.
54
Note: There is a white line on
the fiber that is inserted
in the emitter-side port.
Flexible
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Special-beam Models Convergent-reflective Models
E32-L86
Break-resistant
R25
Two, 3.2 dia. mounting holes with
two, 6 dia. countersinks on one side
27
5.5
22.5
Note: The maximum allowable temperatures
for sections A and B are 200°C and
110°C, respectively. The section inserted
into the Amplifier Unit (indicated by *),
however, must stay within the Amplifier
Unit's operating temperature range.
Two, 2.8 dia. flexible tubes (SUS304)
Two, 4 dia.
4 dia.
8.9 18
5 (max.)
(SUS304)
19
Sensing surface
*
7
2,000
33.5
25(B)
A
E32-L64
R25
Mounting holes Two, 3.4 dia.
Two, 6.3 dia. countersinks
Sensing surface
5
Two, 4 dia.
14
Note: The maximum allowable temperatures are 300°C for
section A and 110°C for section B (section inserted into
the Amplifier Unit).
Two, 2.9 dia. flexible tubes
(stainless steel)
10.7
6.5
(SUS304)
Mounting holes
2.2 dia.
8.9 18
2-M3
18
25
2,000
30(B)
A
E32-A10
6.5±0.1
4 dia.
R25
Mounting holes Two, 3.2 dia.
Two, 6.2 dia. countersinks
Sensing surface
4
Model display tube: 3.3 dia.
(45)
8.4
6
16.5
Mounting holes
8
Two, 2.2 dia.
7±0.1
3.5
2-M3
(ABS)
2
6
4
7
21
2,000
Mounting hole dimensions (recommended)
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R@ Standard
(Unit:mm)
A
Minimum bending
radius
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Fluororesin coating
R25
R30
R35
R40
55
Fiber Units with Reflective Sensors
Flexible
R35
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Environment-resistant Models Heat-resistant Models
E32-D51
Break-resistant
M6×0.75 (brass/nickel plating)
Width 10, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
Sensing surface
Two, 1.5 dia.
Two 2.2 dia.
4.9
3
3.1
13
17
2,000
Note: The maximum allowable temperature is 150°C. The maximum
allowable temperature for continuous operation is 130°C.
E32-D81R-S R10
E32-D81R R10
Using the E32-D81R-S
Using the E32-D81R
Note 1. The maximum allowable temperatures
for sections A and B are 200°C and
110°C, respectively. The section inserted into the Amplifier Unit (indicated
by *), however, must stay within the
Amplifier Unit's operating temperature
range.
M4×0.7
M6×0.75 (SUS303)
Sensing surface
1.2 dia.
Width 10, thickness 2.4 (SUS303)
Washer (SUS)
Protective tube
SUS303
Fluororesin tube
2.2 dia.
2.2 dia.
4.5 8.5
3
2
(70)
5
*
5
20
*
2,000
A
6.4
29.5(B)
25(B)
E32-D61-S R25
E32-D61 R25
Using the E32-D61-S
Using the E32-D61
Note 1. The maximum allowable temperatures
for sections A and B are 350°C and
110°C, respectively. The section inserted into the Amplifier Unit (indicated by
*1), however, must stay within the Amplifier Unit's operating temperature range.
Sensing surface 1.4 dia.
M6×0.75 (SUS303)
Hexagonal caulking
Width 10, thickness 2.4 (SUS303)
Washer (SUS)
M4×0.7
5 dia. *2
SUS316L
2. Order the Fiber Unit based on the Amplifier
Unit. Use the E32-D61-S if the E3X-DA@-S,
E3X-MDA@, or E3X-DAC@-S is used. Use
8 15
the E32-D61 if any other Amplifier is used.
2.2 dia.
SUS flexible tube 3.5 dia.
4.5 8.5
3
2
20
5
*1
2,000
5 *3
6.4
*1
25(B)
A
2. Order the Fiber Unit based on the Amplifier
Unit. Use the E32-D81R-S if the E3XDA@-S, E3X-MDA@, or E3X-DAC@-S is
used. Use the E32-D81R if any other
Amplifier is used.
8 15
29.5(B)
*2. The diameter is 6 dia. if the fiber length exceeds 10 m.
*3. The diameter is 10 if the fiber length exceeds 10 m.
E32-D73-S R25
E32-D73 R25
Sensing surface
1 dia.
Using the E32-D73-S
Using the E32-D73
Note 1. The maximum allowable temperatures for sections A, B, and C are
400°C, 300°C, and 110°C, respectively. The section inserted into the
Amplifier Unit (indicated by *), however, must stay within the Amplifier
Unit's operating temperature range.
M4×0.7 (SUS303)
Stainless-steel tube
1.25 dia.
2.5 dia.
1.65 dia.
Width 7, thickness 2.4 (SUS304)
Washer (SUS)
SUS flexible tube 2.8 dia.
2.2 dia.
4 dia.
Hexagonal caulking
SUS316L
4.5 8.5
5
5
A
5
*
20
60
10
*
2,000
B
25(C)
2. Order the Fiber Unit based on the
Amplifier Unit. Use the E32-D@-S if the
E3X-DA@-S, E3X-MDA@, or
E3XDAC@-S is used. Use the E32-D@ if
any other Amplifier is used.
8 15
6.4
29.5(C)
Environment-resistant Models Chemical-resistant Models
E32-D12F
E32-D14F
R40
R40
7 dia. (fluororesin)
5 dia.
6 dia. (Fluororesin)
4.5
56
26
2,000
16
2,000
Two, 2.2 dia.
Two, 2.2 dia.
100
Optical axis confirmation mark (red)
100
Flexible
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Application-corresponding Fiber Units
Label-detection Models
E32-G14
R25
36.3
20
(ABS)
9.2
2,000
R1.6
R1.6
R3.5
Lens
(PMMA)
24
3.2
10 Optical axis
9
Two, 2.2 dia.
4
1.6
1.6
23.5
9.4
8.4
Liquid-level Detection Models
E32-D36T
R4
Two, 2.2 dia.
R10
Enlarged illustration of sensing surface
15
Emission side: Sixteen, 0.265 dia.
4
5
2
Eight, R0.5
5
11.4
20.4
23.45
2,000
Reception side: Sixteen, 0.265 dia.
13.25
5
4.4
E32-L25T
R10
Sensing surface
Sensing surface Lens two, 3.2 dia. (PC)
2.8
1.2
E39-F9: Included
16
(13) 15.2
Mounting holes
6
10
Two, 1 dia.
(PC)
6
18
Mounting hole dimensions (recommended)
2,000
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
14 0 dia.
Fluororesin coating
R@ Standard
(Unit:mm)
A
Minimum bending
radius
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
dia.
R4
R10
Outer diameter of
fiber unit
3.5 dia.
F dimensions
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R25
R30
R35
R40
57
Fiber Units with Reflective Sensors
Flexible
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
Application-corresponding Fiber Units
Liquid-level Detection Models
E32-A01
E32-A02
R4
R4
(ABS)
(ABS)
Two, 2.2 dia.
Two, 2.2 dia.
14.5
17.8
4.5
3.3
1.7
(PBT)
4.2
(PMMA)
(ABS)
20
Sensing surface
(2 × 11)(PMMA)
5,000
27
7
3
12
4.5
Receiver
19.9
5,000
27
31.2
31.5
Optical axis
Optical axis
21.5
Emitter
E32-D82F1
E32-D82F2
R40
R40
Fiber connector 9 dia.
(brass/nickel plating)
8 dia.
6 dia. (Fluororesin)
Note: The maximum allowable temperatures
for sections A and B are 200°C and
85°C, respectively.
Two, 2.2 dia. *2
To the Amplifier Unit
27
7.2
Length of unbendable
350) *1
section: 150 (350
42
2,000
2,000
A
B
1,500 mm from the tip
*1.( ): E32-D82F2
*2.The 2-m section of optical fiber on the Amplifier-unit side is plastic and therefore allows free cutting.
Models for Glass-substrate Alignment/Mapping
E32-A08 R25
E32-A07E1 R25
E32-A07E2 R25
3.8
E32-L66
(SUS303)
R25
Two, 3.2 dia. mounting holes with
6 dia. Countersinks on one side
10.7 6.5
Two, 2.2 dia. *1
(ABS)
18
14
4
2.2 dia.
12
Sensing surface
1.1
Two, 3.2 dia. mounting holes
with two, 6 dia. countersinks *2
24.5
1
3.3
Sensing
surface
21.7
5
7
4 dia.
*
2,000
2,000
25(B)
A
5
5.5
36
*1 The E32-A07E1/E32-A07E2 has a reception fiber and an emission
fiber. Use the fiber with a model display tube (fiber with blue dotted
line) as light emitting side.
*2 E32-A08 : Countersinks on one side
E32-A07E1/E32-A07E2 : Countersinks on both sides
E32-A08H2
Two, 2.8 dia. flexible tubes (SUS304)
Note: The maximum allowable temperatures for sections A and B are
300°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier
Unit's operating temperature range.
R25
Note: The maximum allowable temperatures for sections A
and B are 300°C and 110°C, respectively.
Mounting holes Two, 3.4 dia.
Two, 6.3 dia. countersinks
1.5
Sleeve (Aluminum)
(5)
5
4 dia.
4 dia. 8.6
2-M3
6.5±0.1
2.2 dia.
18
8
Sensing surface
4
6.5
26
3,000
A
58
Mounting holes
Flexible tube:
Two, 2.9 dia
(stainless steel)
(SUS303)
10.7
30(B)
Flexible
Break-resistant
Fluororesin coating
R@ Standard
Cutting free (Cutter provided)
E32-A09 R25
E32-A09H R35
E32-A09H2
Sensing surface
Lends 5 dia.
Sensing surface
Lends 5 dia.
9
R25
9
Two, 3.2 dia. mounting holes
with two, 6 dia. countersinks
on both sides
(SUS303)
Two, 2.8 dia.
flexible tubes
(SUS304)
(aluminum)
24 8.9
*
Two, 2.2 dia.
8.9
20
12 7
5
30
12
Two, 3.2 dia. mounting holes with
two, 6 dia. countersinks on one side
7
23
2.2 dia.
4 dia.
2,000
2,000
A
28(B)
Note: The maximum allowable temperatures for sections A and B
are 300°C and 110°C, respectively. The section inserted into
the Amplifier Unit (indicated by *), however, must stay within
the Amplifier Unit's operating temperature range.
Wafer-mapping Models
E32-A03
E32-A03-1
0.4
R10
4.5
Stamp
3.2 (1 dia.)
10
Stamp (1 dia.)
E39-F9: Included
3.5
3
4.3 17.6 11
3 dia.
3.4
1 dia.
3 dia.
2,000
20.5
1.8
Two, R1.6
3.2
2
10
E39-F9: Included
24.5
(brass/nickel plating)
R1.6
Mounting holes
Two, 3.4 dia
6.5 3
12.5
18.5
Sensing surface
2 dia.
E39-L83 Mounting Bracket
(SUS) (provided)
2,000
(brass/nickel plating)
13
Note 1. Use the stamped surface and its opposing surface as installation (reference) surfaces.
2. Set of two symmetrical parts.
Sensing surface: 2 dia.
Note: Use the stamped surface and its opposing surface as installation (reference) surfaces.
E32-A04
R10
2 dia.
(SUS303)
E32-A04-1
E39-F9: Included
1 dia.
R10
2
1 dia.
2 dia.
2
2
2
4
2,000
20.5
Stamp (1 dia.)
1.2
2.5
3.5
17
21
2,000
Mounting hole dimensions (recommended)
(SUS303)
2
Note: Use the stamped surface and its opposing surface as installation (reference) surfaces.
E39-F9: Included
2-M2
10
4
Sensing surface
1.2 dia.
Sensing surface: 1.2 dia.
2
9
installation
(reference)
surfaces
Note: Set of two symmetrical parts.
Minimum bending radius
unbendable
B
Sensing
head
Minimum bending radius
A
F
<Screw-mounting Model>
Outer diameter of
fiber unit
(Unit:mm)
M3
3
F dimensions
+0.5
0
dia.
M4
4
+0.5
0
dia.
M6
6
+0.5
0
dia.
Flexible
Break-resistant
M14
+1
0
14 dia.
Fluororesin coating
R@ Standard
(Unit:mm)
A
Minimum bending
radius
B
unbendable
(except E32-C11N, E32-C31N
and E32-CC200)
1
0
(E32-C11N, E32-C31N,
E32-CC200R)
4
0
4
10
25
30
35
40
10
10
10
10
10
10
Type
Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia.
<Cylindrical Model>
Outer diameter of
fiber unit
F dimensions
Outer diameter of
fiber unit
F dimensions
(Unit:mm)
1 dia.
1.5 dia.
2 dia.
3 dia.
+0.2
0
+0.2
0
+0.2
0
+0.2
0
1.2
dia. 1.7
dia. 2.2
dia. 3.2
dia.
R4
R10
3.5 dia.
4
+0.5
0
dia.
4 dia.
5 dia.
6 dia.
+0.5
0
+0.5
0
+0.5
0
4.5
dia. 5.5
dia. 6.5
dia.
Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia.
R25
R30
R35
R40
59
Accessories
Lens Units
Lens Units
E39-F1
Side-view Units
E39-F2
M2.6×0.45
Effective depth: 3.
Spot-facing depth
2.8 dia.
4 dia.
4 dia.
5.7
8.9
Material:
Brass for the body and optical glass for the lens itself.
9.2
Material:
Brass for the body and optical glass for the lens itself.
Note: Two per set.
Note: Two per set.
Reflection Unit with Lens
E39-F3
Two, 4 dia.
M3 internally
toothed washer
Two, M3×3
Two, 3.2 dia. slotted-head set screws*
12
6.4
18
6.4
3
8±0.2
3.6
M3 × 6
angle-settingscrew
6.5
Material:
Brass for the body and aluminum for the base.
* Secure the fiber head with the slotted-head set screws. Do not insert a
lens (E39-F1).
20.7
8.5
Lens Unit for Reflective Fiber Units
E39-F3A
Lens Unit for Reflective Fiber Units
E39-F3A-5
M2×2 Allen-head set screw
(for securing the fiber)
Straight knurling
3
Lens surface
(lens diameter: 3.7 mm)
13
2.1 dia.
23
Note: This is the Lens Unit for the E32-D32 and E32C42.
Lens Unit for Reflective Fiber Units
E39-F3B
Lens surface
(lens diameter: 3.7 mm)
Material:
Aluminum for body and optical
glass for lens
2.1 dia.
5 dia.
4 dia.
6 dia.4 dia.
Material:
Aluminum for body and
optical glass for lens.
M2.6
Effective depth: 3.2
Spot-facing depth: 0.9
16.5
M3×0.5
Effective screw
length: 3
6.5
Note: This is the Lens Unit for the
E32-C31 and E32-C41.
Lens Unit for Reflective Fiber Units
E39-F3C
Straight knurling
6 dia. 5.5 dia.
Lens surface
(lens diameter: 4.8 mm)
Material:
Aluminum for body and
optical glass for lens.
60
24.1
25.2
Note: This is the Lens Unit for the
E32-C31 and E32-C41.
5 dia.
4.3 dia.
M3×0.5
Depth: 4.4
5.8
Lens surface
(lens diameter: 3.7 mm)
Material:
Aluminum for body and
optical glass for lens.
10.9
M3×0.5
Effective screw
length: 3
Note: This is the Lens Unit for the
E32-C31 and E32-C41.
Protective Spiral Tubes
E39-F32A/F32A5
E39-F32B/F32B5
Head connector (brass/nickel plating)
M3×0.5 Depth: 4
End cap (brass/nickel plating)
3 dia.
6 dia.
12
tube 4.6 dia. (SUS304)
12
L
Note 1. The length L is 1,000 for the E39-F32A/-F32B and 500 for the E39-F32A5/-F32B5.
2. The E39-F32B(5) consists of two E39-F32A(5)s.
E39-F32C/F32C5
End cap (brass/nickel plating)
4 dia.
Head connector (brass/nickel plating)
M6×0.7 Depth: 4
7 dia.
12
tube 5.6 dia. (SUS304)
12
L
Note: The length L is 1,000 for the E39-F32C and 500 for the E39-F32C5.
E39-F32D/F32D5
End cap (brass/nickel plating)
Head connector (brass/nickel plating)
5 dia.
M6×0.75 Depth: 4
8.5 dia.
12
tube 7 dia. (SUS304)
12
L
Note: The length L is 1,000 for the E39-F32D and 500 for the E39-F32D5.
61
Accessories
Other Accessories
Fiber Cutter
E39-F4
8
Thin-fiber Attachments
E39-F9
45
1.1 dia.
2.2 dia.
24.5
10
Material: ABS
Fiber Connector
E39-F10
25
Note: Two per set.
*Provided with thin-fiber models.
Thin-fiber
insertion hole
Standard-fiber
insertion hole
3.6 dia.
11.7
Optical fiber: 2.2. dia.
Retention clip (Brass)
Retention clip (Brass)
Splice (Polyester)
3.8 dia.
Optical fiber: 2.2. dia.
3 dia.
26
12.8
Fiber Connector
E39-F13
E39-F14
E39-F15
(48.6)
32.6
9.2
7.6
29.6
2
3.2
Note: Dimension A varies with
the model number as shown
in the following table.
8
33.8 22.4 20.4
27.4
Four, 6 dia
4-0.8
Four, A
(See note.)
Sleeve Bender
E39-F11
42.5
10
10
10.8
Model
E39-F13
E39-F14
E39-F15
Dimension A
2.4
1.2
2.4/1.2
Four, R0.8
Mounting Bracket
E39-L83
0.4
Six, R1.2 1.8
3.2
3.5
27
R10
R12.5
R1.6
2.8
62
4.3
Two, R1.6
R5
R7.5
3.2
10
11
17.6
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Fiber Units
● Mounting
Tightening Force
The tightening force used to mount the Fiber Unit must not be
more than the value given in Ratings/Characteristics.
Screw-mounting Model
Cylindrical Model
Fiber Cutting Procedure
Cut a thin fiber as follows:
The fiber is shipped
loosely tightened as
shown in the figure
(1) at the right.
Thin fiber attachment
(E39-F9)
Temporarily fitted
Adjust the fiber to
the desired length
(2)
and then tighten it
securely.
Insert the fiber to be
cut into the E39-F4.
Cutter
(E39-F4)
(3)
Two holes for
thin fiber
Spring mounting clip
Retaining screw
(flat head or sunken head)
(M3 max.)
Toothed washers
Three holes for
standard fiber
(2.2-mm dia.)
Finished state
(proper cutting
state)
Use a proper-sized wrench.
Nuts
(attachment)
Approx. 0.5 mm
(4)
Insertion direction
Note: Insert the fiber into the amplifier
the direction indicated by the
arrow.
Chemical-resistive Models
The following method is recommended to prevent the fluororesin case
from cracking when the Sensor is being secured. Be especially
careful not to crack the case when using screws to secure the Sensor.
Fiber Sensing Head
Connection
• Do not excessively pull or press the Fiber Unit. Use a pulling
force no higher than what is given in Ratings/Characteristics.
• Do not bend the Fiber Unit beyond the permissible bending
radius given under Ordering Information.
• Do not bend the edge of the Fiber Units
(excluding the E32-T@R and E32-D@R).
Correct
Incorrect
10 mm min.
Amplifier Unit
Fiber Unit
10 mm min.
• Do not apply excess force on the Fiber Units.
Correct
Incorrect
Fiber Unit
Nylon wireholder
The Fiber Head could be broken by excessive vibration. To
prevent this, the following is effective:
A one-turn loop can
absorb vibrations.
Tape
63
E39-F11 Sleeve Bender
• The bending radius of the stainless steel tube should be as
large as possible. The smaller the bending radius becomes,
the shorter the sensing distance will be.
• Insert the tip of the stain1.2 mm dia. max.
less steel tube to the
1.3 mm dia. min.
R10 mm
Sleeve Bender and bend
the stainless steel tube R12.5 mm
R5 mm
slowly along the curve of R7.5 mm
the Sleeve Bender.
Fiber tip
position
mark
90° max.
Stainless
steel tube
10 mm
10 mm
E32-A07E1(E2)
There is a difference in sensing
object angle between E32-A07E1
and E32-A07E2. Select a model in
accordance with the bending
direction of a sensing object. Use
the fiber with a model display tube
as light emitting side.
View from the cable drawing side
Sensing object
Emission Reception
E32-A07E2
Reception Emission
E32-A07E1
● Adjustment
Do not bend here.
Heat-resistant Fiber Units
(E32-D51 and E32-T51)
• The fibers of these Units cannot be extended using the E39F10 Fiber Connector.
• The maximum allowable temperature for continuous operation with these Units is 130°C. It is 150°C for short-term use.
E32-T14 and E32-G14
These Units may enter the light-ON
state if there are reflecting objects at
the ends of the lenses. In this case,
attach the black stickers provided to
the ends of the lenses.
Stickers
Wafer Sensors (E32-L25(A))
• To ensure correct performance, insert the fiber with a white
line into the emitter-side port of the Amplifier Unit.
E32-T16 and E32-T16P
Example
E32-T16's sensing head
Slit provided
To use the slit provided, peel off the
backing sheet, align it with the edges of the sensing surface, and attach it to the sensing head. Use the
slit in applications where saturation
occurs (i.e., changes in light intensity cannot be obtained) due to
short sensing distances.
E32-M21
Separate the 4 fibers by distances sufficient to prevent interference.
Vacuum-resistant Fiber Units (E32-V)
Although Flanges, Fiber Units on the vacuum side, and Lens
Units have been cleaned, as an extra precaution, clean these
products with alcohol before use in high-vacuum environments to ensure that they are properly degreased.
Liquid-level Detection Sensors (E32-D82F)
• Secure the Fiber Unit using the unbendable section. Otherwise, the liquid-level detection position may be displaced.
• For applications in hazardous environments, install the Fiber Unit in the hazardous environment but install the Amplifier Unit in a safe environment.
64
Liquid-level Detection Sensors: Tube-mounting Models
• Ensure that the tube is not deformed when using a band to
secure the Fiber Unit.
• Drops of water, bubbles, or haze inside the tube may cause
malfunctions.
E32-G14
When a Digital Fiber Amplifier is used, the sensing distance is
short, making the incident light intensity large. This makes it
impossible to teach without a workpiece.
Liquid-level (E32-D82F) Detection Position
The liquid-level detection position is at a distance of
5.2±2 mm from the end of the
fluororesin section.
Liquid-level detection
position
(Refer to the diagram on the
5.2±2 mm (from the end of the
right.)
fluororesin section)
The liquid-level detection position varies with the surface
tension of the liquid and the degree of wetness at the Fiber
Unit's detection position.
● Other Considerations
Liquid Level (E32-D82F)
• Operation may become unstable in the following cases:
A Bubbles stick to the cone of the sensing head.
B Solute is deposited on the cone of the sensing head.
C The liquid has a high viscosity.
• There are some liquids, such as milky white liquids, for
which detection is not possible.
• Do not let the end of the fluororesin section bump into another object. Damage to, or deformation of, the sensing
head may result in unstable operation.
Heat-resistant Fiber Units (E32-D81R(-S), E32-D61(-S), and
E32-D73(-S))
The pitch of the emission-side and reception-side fiber-insertion ports varies with the Amplifier Unit. Be sure to use an appropriate Fiber Unit.
Amplifier Unit
E3X-DA@-S
E3X-MDA@
E3X-DA@-N
E3X-NA@
Fiber Unit
E32-D@-S
E32-D@
Chemical-resistant Fiber and Liquid Level (E32-D82F)
Fluororesin has high chemical resistance. However, applications in
the atmosphere of vaporized chemicals (gases) or steam may cause
malfunction or damage inside sensors. Run a full check before using
in such environments.
■ Accessories
Use of E39-R3 Reflector
1. Use detergent, etc., to remove any dust or oil from the
surfaces where tape is applied. Adhesive tape will not be
attached properly if oil or dust remains on the surface.
2. The E39-R3 cannot be used in places where it is exposed
to oil or chemicals.
E39-F32@ Protective Spiral Tubes
1. Insert a fiber to the Protective
Spiral Tube from the head
connector side (screwed) of the
tube.
2. Push the fiber into the
Protective Spiral Tube. The
tube should be straight so that
the fiber is not twisted when
inserted. Then turn the end cap
of the spiral tube.
3. Secure the Protective
Spiral Tube on a suitable
place with the attached
nut.
Fiber Unit
Splice
Fiber Unit
Protective Spiral
Tube
Fiber Unit
Retention unit
Retention
unit
Fiber Unit
Protective Spiral
Tube
Mounting panel
Protective Spiral
Tube
4. Use the attached saddle to
secure the end cap of the
Protective Spiral Tube. To
secure the Protective Spiral
Tube at a position other than
the end cap, apply tape to the
tube so that the portion
becomes thicker in diameter.
E39-F10 Fiber Connector
Mount the Fiber Connector as shown in the following
illustrations.
1. Insert the Fiber Unit into the retention clip.
2. Insert the retention clip into the splice.
Fiber Unit
Fiber Unit
• The Fiber Units should be as close as possible when they
are connected.
Sensing distance will be reduced by approximately 25%
when fibers are connected.
• Only 2.2-mm dia. fibers can be connected.
Hexagon clamping nut
Fiber Unit
Toothed washer
Saddle
Tube
End cap
65
66
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.